Loading...
HomeMy WebLinkAboutMiscellaneous - 3 WILSON ROAD 4/30/2018 (2)Arthur Redmond (111111L' ) Wilson APPLICATION FOR SEWAGE DISPOSAL INSTALIATION HEALTH DEPARTMENT - NORTH ANDOVER, MSS. I hereby make application for a permit for a sewage disposal installation at _ :dilscn Rd. Turnpike St. . I will install this system in ac- cordance with all the laws of the Commonwealth of Massachusetts and regulations of the Board of Health of the Town of North Andover. Further, I will construct the house sewer of bell and spigot pipe, the minimum diameter being 4 inches, and will maintain a minimum grade of 1% until 10 feet pre- ceding the septic tank, where the grade shall not exceed 2%. I will install a con- crete septic tank of 7h0 Gal, in size. A manhole (s) permitting easy cleaning will be provided with removable cover (s) of iron or concrete within 12 inches of the ground surface. I will provide subsurface disposal field with 4 inch perforated or open jointed pipe and laid in a series of trenches, the bottom of which will pro- vide a minimum of 180 lineal (;Wx1LJ feet of effective absorption area. The pipes will be laid on a 6 inch layer of washed gravel or crushed stone ranging in size from 3/4 to 1-1/2 inches (dia.) and the pipes will be surrounded by similar material to a height of 2 inches above the crown of the pipe. The joints of these pipes will be protected from clogging and before filling the trench, 2 inches of gravel or stone 1/8" to 1/4'f (dia.) will be placed over the course gravel or stone. The disposal field will be installed at a grade of 4 to 6 inches/100 feet. No single tile line will exceed 100 feet in length and in any case, two lines of tile will be installed. A minimum of 6 feet will be maintained between the center lines of the disposal field trenches and the average depth of trench shall not exceed 36 inches. No part of the installation will be less than 100 feet from any private water supply, 25 feet from any stream, 20 feet from any dwelling or 10 feet from any property line. I further agree not to cover any portion of this installation until approved by the inspection officer, as provided below, and to incorporate any additional requirements that may be attached to the permit. Plot Plans must be submitted with application. DATElh;-Y x-37 1 9 'fes /. Signature of Applicant I hereby issue the above permit for the Board of Health of the Town of North Andover, Massachusetts. DA gnature of Health Agent I have inspected the uncovered system indicated above and find everything done as described. DATE �7 r S I /_ Signature of qJ3pecting Officer Percolation Test 5 min. Sandy -clay, Garbage Grinder no BOARD OF HEATTH TONN OF NOM -11 AAIL04'ER, MASS. r10Olt v_ o_ d � in w T omi l u ve1� �-- 1. NAME .44 DATE AC�-S .1. . 2. ADDRESS:C .� . ? . j�,.i� -T., . LOT N0. . . TEL. . . . . 3. NO. OF BEDROODIS . . . DEN YES . . . . N0. . l�. GARBAGE GRINDER YES . . . . . NO. . 5, SHOW DIIa.,ENSIONS OF HOUSE b. SHOW DISTANCES OF HOUSE TO ALL PROPERTY LINES 7. SHOW DII,ENSIO16 OF LOT 8. SHOW LOCATION AND SIZE OF SEPTIC TANK OR CESSPOOL 9. NOTE LOCATION AND DISTANCE OF WELL FROM SEWERAGE SYSTEM tw 10. SHOW LOCATION OF BROOKS, STPLA159 DITCHES, LEDGE OUTCROP, ETC. // 11. SHOW DISTANCE OF SEPTIC TANK OR CESSPOOL FROM HOUSE NOTE: : LOCAL REGULAT IOALS SHOULD BE READ CAREFULLY. October 31, 1959 Miss Mary Sheridan R. N. He a.lt h Agent Board of Health North Andover, Maas. Deer Miss Sheridan: - An examination was made as requested in order to determine the suitability of the soil for the subsurface disposal of sewage on the proposed building site of Arthur r. Redmond at the corner of Wilson Road and Turnpike Street. The subsoil in the area was of a sandy clay content and a 5 -minute percolation test was conducted. The land in general is high. It is recommended that a 750 gallon concrete septic tank be installed together with 180 lineal feet of drain pipe. Very truly yours, 91i11iam J. ifs; eo11