Loading...
HomeMy WebLinkAboutMiscellaneous - 35 High StreetLI) Ln x w n cD cD ft i S. RUSSELL SYLVA Commissioner 935-2160 December 27, 1985 Card Tek, Inc. RE: N. ANDOVER - Metropolitan Boston/ 200 Merrimack Street Northeast Region Lawrence, Massachusetts 01843 310 CMR 7.02 - Plans Approval Application No. MBR -84 -IND -049 FINAL APPROVAL Attention: Mr. A.W. Vinciguerra Gentlemen: The Metropolitan Boston/Northeast Region of the Department of Environmental Quality Engineering, in reply to the request contained in your letter dated July 5, 1984, has reviewed the plans, specifications, and the Standard Operating and Maintenance Procedures relative to the-existing,...unapproved.reverberatory furnace located at your foundry located at 35 High Street in North Andover, Massachusetts. The submitted information bears the seal and signature of Mr. Charles H. Marks, Massachusetts P.E. No. 24759. A review of the submitted information by Department engineers indicates that the subject foundry has installed a Reda Series 550 reverberatory melting furnace to melt pig (gray) and scrap iron. This furnace is used to melt a maximum of 600 pounds of metal per melt. The uncontrolled particulate and lead emissions associated with this process are estimated to be discharged at rates of 0.6 pounds per hour and 0.042 pounds per hour respectively. The exhaust gases are vented through a metal stack, the top of which is 41 feet above ground level. This stack has an inside exit diameter of 2 feet which will permit a flue gas exit velocity of 34 feet per second at a temperature of 600°F. The stack is equipped with a rainhat which redirects the vertical flow of the exhaust gases to a horizontal direction. The Department is of the opinion that the plans, specifications, and the Standard Operating and Maintenance Procedures pertinent to the submittal are in conformance with current air pollution control engineering practice, and hereby grants FINAL APPROVAL for*the subject reverberatory furnace, as submitted, with the following provisos: I. That particulate emissions from the reverberatory furnace not exceed the stated levels of 0.6 pounds per hour of particulates and 0.042 pounds per hour of lead. 2. That emissions testing be conducted to demonstrate compliance with the stated emission limitations when and if the Department should deem such testing necessary. 3. That should any nuisance condition(s) be generated by the operation of this facility, then appropriate steps will immediately be taken by Card Tek, Inc. to abate 'the nuisance condition(s). Card Tek, Inc. Page -2- Failure to comply with the above stated provisions will constitute a violation of the "Regulations," and can result in the revocation of the approval granted herein to operate the described facility. The Department may also revoke this approval if the construction work is not begun within two years from the date of issuance of this approval, or if the construction work is suspended for one year. For Air Quality Control purposes, an Environmental Notification Form is not required to be submitted for this project since it is exempt under the Environmental Protection Regulations of the Executive Office of Environmental Affairs, and the project has been determined to cause no significant damage to the environment. Please be advised that this approval does not negate the responsibility of the Card Tek, Inc. to comply with this or any other applicable federal, state, or local regulations in the future. Should you have any questions concerning this matter, please do not hesitate to contact Mr. Michael J. Maher, Air Quality Section Chief, at 5 Commonwealth Avenue, Woburn, Massachusetts 01801. ry truly yours, Richard J. C pin Acting Regional Environmental Engineer RJC/Elo/pd cc: Board of Health, City Hall, Lawrence, MA 01840 Fire Department, City Hall, Lawrence, MA 01840 DAQC, One Winter Street, Boston, MA 02108 - 8th Floor 3