HomeMy WebLinkAboutMiscellaneous - 453 JOHNSON STREET 4/30/2018 (2) 453 JOHNSON STREET t 2]0/098A-0069-D000.0 f Board of HealthSEPTIC SISTE�i North An¢overiM"s 1W INSTA.d.ATICK CHECK LIST _AXO OVED DATE DI SAPPROPED AVATI CEJ Old RAI L easonst nn OK . 1. Distance To: -7 -�5 bCG 90 00 —It-((s s9wroo as wetlands b. Drains r' L�jr • c.. well u '� 2. Watar Dine Location K KEA 3• No .7C Pipe 4. Sep tic Tank a. . fees -_Length & To Clean Out Covers b. -Cement Pipe .to Tank On Both Sides of Tank Distribution Box a. ,Covers & Boic - No Cracks . b. All bines 'Flowing Equal Amounts c. No Back Flow 6. Leach .Field or Trench a. Dimensions b. Stone Depth ' a ' Capped Ends • d. Clean Double-Washed Stone f 7•. LF-tch Pits a. Di.riensions b. Stone Depth LC. , 9p- .sh'P ads . d. rebs e. cement Pipe to Pit - Both Sides f. lean Double Washed Stone f 3 8. No Garbage Disposal 9. -Fir al Grading Inspection 10. Barricading Covered System 11. As Built Submitted a. Lot Location b. Dimensions of System c. Location with Regard_to.Pere Test d. Elevations e. Water Table ORDER OF CONDITIONS: Lot 14 Salem Street' a. Notice of Intent of Forbes Realty Trust/Prepared by Christiansen Engineering, Inc./Dated July 1, 1985/Eight pages (8) . b. Plan titled "Subsurface Disposal System" Lot 14 Salem Street, North Andover, MA/Prepared by Christiansen Engineering Inc./Dated April 30, 1985, Revised June 25, 1985/Two (2) sheets (L of 3 and 2 of 3) . 13. The NACC has determined that the plans submitted under this filing, and also under filings for Lots 8,9,10,11,12 and, ' 13 contained certain inaccuracies which make it difficult for the NACC to evaluate the proposed._work, (i.e. inconsistent delineation of wetlands and buffer zones) . Therefore, prior to any work being done on this lot, the following shall be submitted to the NACC for its approval. a. Revised plans, drawn accurately, and to scale, so that the NACC- can match the plans for all the above mentioned lots in order to determine the overall wetlands configuration, flow direction, and size. b. or, one plan, combining all lots, with wetlands and buffer zone delineated, as well as houses, drives, and associated appurtenances. c. and a plan and calculations, showing how the applicant intends to decrease, , or maintain at zero, the rate of runoff, for this individual lot. e - d. or, rather than item 13c, the applicant may prouide an overall."plan and calculations, showing lots 8 - 14 (inclusive) , and those measures which will be employed to maintain at zero, or decrease, the change in the rate Of runoff for the entire area (lots 8 - 14 inclusive) . 14. Upon receipt of the above required information, the NACC, if necessary shall issue, within 21 days, additional conditions necessary to adequately protect adjacent wetland areas. 15. The provisions of this Order shall apply to and be binding upon the applicant, its employees, and all successors and assigns in interest or control. 16. Prior to the issuance of a Certificate of Compliance, the applicant shall submit a letter to the Conservation Commission from a registered professional engineer certifying that the work is in compliance with the plans referenced above and the conditions stated above. 17. Members of the NACC shall have the right to enter upon and inspect the premises to evaluate compliance with this Order of Conditions. 18. Accepted engineering and construction standards and procedures shall -be followed in the completion of the project. t CtA 1