Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Miscellaneous - 46 COMPASS POINT ROAD 4/30/2018
/ BUILDING FELE � NORrH� O Sieo abs tip F-2 y°,p n p71 Complaint# f opQ y M A.{TED 4SSACHUSE� Inspectional Services Complaint Investigation Date O! 50 0&2 " m la aken By Address In Question 46 C e7,4P, l Map X06 Lot Property Owner 6-{f4f &V 7-H Zon Complaintff�A� Person Making Complaint Phone Complainant's Address CESS �6¢r' By Telephone In Person By Mail Inspector Assigned ��` Action Needed: Return Call Site Inspection Send Letter Date Sent Inspector's Notes 4Z d/ 201, ., s Further Actiony� � � xUS�- �z oZz ��i „may N l I int Tracking Initial Date of Complaint cel 10 Additional Action Required Site Visit Date d2l Letter Sent Date Date Investigation Closed Follow Up Date Time Spent On Complaint 6/20/2016 Date: June 20, 2016 20619 This is an e-permit.To learn more,scan this barcode or visit northandoverma.viewpointcloud.com/#/records/20619 • • ��,hru lea • t _ N �' TOWN OF NORTH ANDOVER IM, . AM PERMIT FOR WIRING ■ This certifies that Robert W Rose has permission to perform new home wiring in the buildings of Trust Construction co at 46 COMPASS POINT , North Andover, Mass. Lic. No. 11044 1/1 6/9/2016 I I Date:June 09,2016 20548 This is an e-permit.To learn more,scan this barcode or visit northandoverma.viewpointcloud.com/#/records/20548 Nn TOWN OF NORTH ANDOVER PERMIT FOR GAS INSTALLATION This certifies that James S Laurencio has permission for gas installation GASPIPING FOR SINGLE FAMILY in the buildings of BERRY CO at 46 COMPASS POINT, North Andover, Mass. Lic. No. 15067 1/1 MASSACHUSETTS UNIFORM APPLICATION FOR A PERMIT TO PERFORM GAS FITTING WORK CITY NORTH ANDOVER J, MA. DATE 6-6-16 PERMIT# JOBSITE ADDRESS 46 COMPASS POINT OWNER'S NAME 1,TRUST CONSTRUCTION G OWNER ADDRESS: 151MT JOY DRIVE TEWKSBURY MA 01876978 851 3456 FAX: TEL: TYPE OR OCCUPANCY TYPE: COMMERCIAL❑ EDUCATIONAL ❑ RESIDENTIAL PRINT CLEARLY NEW:❑■ RENOVATION:❑ REPLACEMENT: ❑ PLANS SUBMITTED: YES❑ NO❑ FIXUTRES Z FLOOR— Bsmt 1 2 3 4 5 6 7 8 9 10 11 12 13 14 BOILER BOOSTER CONVERSION BURNER COOK STOVE DIRECT VENT HEATER DRYER FIREPLACE FRYOLATOR FURNACE i GENERATOR GRILLE LABORATORY COCKS MAKEUP AIR UNIT OVEN POOL HEATER ROOM/SPACE HEATER ROOF TOP UNIT TEST UNIT HEATER UNVENTED ROOM HEATER WATER HEATER INSURANCE COVERAGE I have a current liability insurance policy or its substantial equivalent which meets the requirements of MGL.Ch.142 YES ❑■ NO ❑ If you have checked YES,please indicate the type of coverage by checking the appropriate box below. LIABILITY INSURANCE POLICY N OTHER TYPE INDEMNITY ❑ BOND ❑ OWNER'S INSURANCE WAIVER:I am aware that the licensee does not have the insurance coverage required by Chapter 142 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement. SIGNATURE OF OWNER OR AGENT CHECK ONE ONLY: OWNER ❑ AGENT F1 hereby certify that all of the details and information I have submitted(or entered)regarding this app' ation areMel urate to the best of my Knowledge and that all plumbing work and installations performed under the permit issued for thi pplica' n liance with all Pertinent provision of the Massachusetts State Plumbing Code and Chapter 142 of the General Laws. PLUMBER/GASFITTER NAME: jylKE BURKELICENSE# 131.2 SIGN T E COMPANY NAME: I POWERHOUSE PLUMBING AND HEATING CORP ADDRESS: 0 BOX 896__ CITY: I PLAISTOW STATE: NH ZIP: 03865 FAX: 16033780040 TEL: 6033780020 CELL: 9784909385 � EMAIL: JaL RENCIO@POWERHOUSEPLUMBINGAND HEATING.COM MASTER❑■ JOURNEYMAN ❑ LP INSTALLER❑ CORPORATION❑■ #12482 1 PARTNERSHIP❑#=LLC❑#= ROUGH GAS INSPECTION NOTES BELOW FOR OFFICE USE ONLY FINAL INSPECTION NOTES Yes No THIS APPLICATION SERVES AS THE PERMIT ❑ ❑ FEE: $ PERMIT# PLAN REVIEW NOTES I I I .,p'Gx Pertit,2trM8 x — — .- E C' L]hms:Jfilorttlardovtrma vlewpolnhloud mm/r;�-ecx.,J'O°9" ..._____._. ...........__ -- ___-- ._4.... Town of North Andover,MA C, >earch.... 20548 j i -Gas Permit-1n co junction with a Building Permit(Commercial or Residential) I TIMELINE Submission received l" "1 Your request is in progress j.,8,2016etf2:30p,n � J we'll let you know of any updates via email.Feel free to check the status at any time by coming back to this page. OGas Peol RcNe In Progress O Permit) tr�{jt L oPe"rltI s."u" Y � heplica�t Locauct: JAMES LAORENCIO 46 COMPASS POINT,NORTH ANDOVER, MA BERRY CO Attachments tclPwec rra -O7Ipl IF werljun OB 2016 16:31:.POF :Ai:UNC10 Primary Contractor Search for your contractor using the search bar below.Either the Firm's Name or licensees is required. F:rm'.(Ouslne:s)"dame Plumber Gesneer game(ucsenseej` W.tb.B41Netmin IN �2�I IS Wednesday,Jun 08,2016 12:35 PM 6/9/2016 I h I Date:June 09,2016 20547 This is an e-permit.To learn more,scan this barcode or visit northandoverma.viewpointcloud.com/#/records/20547 TOWN OF NORTH ANDOVER Rill �� PERMIT FOR PLUMBING This certifies that James S Laurencio has permission to perform plumbing in the buildings of BERRY CO at 46 COMPASS POINT, North Andover, Mass. Lic. No. 15067 1/ MASSACHUSETTS UNIFORM APPLICATION FOR A PERMIT TO PERFORM PLUMBING WORK - CITY I_NORTH ANDOVER _ . !, MA. DATE 6-6-16 PERMIT# JOBSITE ADDRESS 146 COMPASS POINT OWNER'S NAME TRUST CONSTRUCTION _P -_._ ....._. .- _ .._ __.___ _ -- POWNER ADDRESS: 51 MT JOY DR TEWKSBURY MA 01876 TEL: 978 851 3456 FAX: TYPE OR OCCUPANCY TYPE: COMMERCIAL❑ EDUCATIONAL ❑ RESIDENTIAL❑■ PRINT CLEARLY NEW: t❑ RENOVATION:❑ REPLACEMENT: ❑ PLANS SUBMITTED: YES❑ NO❑ FIXUTRES Z FLOORS— Bsmt 1 2 3 4 5 6 7 8 9 10 11 12 13 14 BATHTUB 2 j CROSS CONN DEVICE DEDICATED SPECIAL WASTE SYS DEDICATED GAS/OIUSAND SYS DEDICATED GREASE SYSTEM DEDICATED GRAY WATER SYS DEDICATED WATER REUSE SYS DISHWASHER 1 DRINKING FOUNTAIN FOOD WASTE GRINDER UNIT 1 FLOOR/AREA DRAIN INTERCEPTOR INTERIOR KITCHEN SINK LAVATORY 1 3 ROOF DRAIN SHOWER STALL 1 SERVICE I MOP SINK TOILET 1 2 URINAL WASHING MACHINE CONNECTION 1 WATER HEATER ALL TYPES 1 WATER PIPING 1 SPIGOTS 2 INSURANCE COVERAGE I have a current liability insurance policy or its substantial equivalent which meets the requirements of MGL.Ch.142 YES NO ❑ If you have checked YES,please indicate the type of coverage by checking the appropriate box below. LIABILITY INSURANCE POLICY 0 OTHER TYPE INDEMNITY ❑ BOND ❑ OWNER'S INSURANCE WAIVER:I am aware that the licensee does not have the insurance coverage required by Chapter 142 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement. CHECK ONE ONLY: OWNER ❑ AGENT ❑ SIGNATURE OF OWNER OR AGENT I hereby certify that all of the details and information I have submitted(or entered)regarding this ap ication are t/inm ate to the best of my Knowledge and that all plumbing work and installations performed under the permit issued for this pplicati n will nce with all Pertinent provision of the Massachusetts State Plumbing Code and Chapter 142 of the General Laws. PLUMBER NAME: MIKE BURKE LICENSE#113127 /�IGYA7URE COMPANY NAME: POWERHOUSE PLUMBING AND HEATING CORP ADDRESS: 0 B01896 CITY:I PLAISTOW STATE: NH ZIP: I 038 5 FAX 16033780040 TEL: 116033780020 CELL: 19784909385_ EMAIL:I J.LAURENCIO@POWERHOUSEPLUMBING.COM MASTER ■❑ JOURNEYMAN❑ CORPORATION 9# 2482 PARTNERSHIP 0# LLC❑4 ROUGH PLUMBING INSPECTION NOTES BELOW FOR OFFICE USE ONLY FINAL INSPECTION NOTES Yes No THIS APPLICATION SERVES AS THE PERMIT ❑ ❑ FEE: $ PERMIT# PLAN REVIEW NOTES The Commonwealth of Massachusetts Department of Industrial Accidents • 4 Office of Investigations 1 Congress Street, Suite 100 W ,W= Boston, MA 02114-2017 www mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): POWERHOUSE PLUMBING CORP Address: PO BOX 896 City/State/Zip: PLAISTOW, NH 03865 Phone #:6033780020 Are you an employer? Check the appropriate box: Type of project(required): 1.0 I am a employer with 6 4. ❑ I am a general contractor and 1 employees (full and/or part-time).* have hired the sub-contractors 6. New construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have g, ❑ Demolition working for me in any capacity. employees and have workers' [No workers' comp. insurance comp. insurance. 9. ❑ Building addition required.] 5. ❑ We are a corporation and its 10.E] Electrical repairs or additions 3.❑ 1 am a homeowner doing all work officers have exercised their 11.F1 Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t c. 152, §1(4),and we have no employees. [No workers' 13.0 Other comp. insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. tContractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: HARTFORD UNDERWRITERS INSURANCE COMP Policy#or Self-ins. Lic. #:04WECIT2480 Expiration Date:7-28-16 Job Site Address: 46 COMPASS POINT City/State/Zip: N ANDOVER, MA Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,5000. d/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.0 a day gainst the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigatio of the A for insurance coverage verification. I do here certify u der the i s and penalties of perjury that the information provided above is true and correct. Siarnatu Date: 6-6-16 Phone 4603380020 Offi 'avusonly. Do not write in this area,to be completed by city or town official. City or Town: Permit/License # Issuing Authority(circle one): 1.Board of Health 2.Building Department 3. City/Town Clerk 4. Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: Information and Instructions Massachusetts General Laws chapter 152 requires all employers to provide workers' compensation for their employees. . Pursuant to this statute, an employee is defined as"...every person in the service of another under any contract of hire, express or implied,oral or written." An employer is defined as "an individual, partnership, association, corporation or other legal entity, or any two or more of the foregoing engaged in a joint enterprise, and including the legal representatives of a deceased employer, or the receiver or trustee of an individual, partnership, association or other legal entity, employing employees. However the owner of a dwelling house having not more than three apartments and who resides therein, or the occupant of the dwelling house of another who employs persons to do maintenance, construction or repair work on such dwelling house or on the grounds or building appurtenant thereto shall not because of such employment be deemed to be an employer." MGL chapter 152, §25C(6)also states that"every state or local licensing agency shall withhold the issuance or renewal of a license or permit to operate a business or to construct buildings in the commonwealth for any applicant who has not produced acceptable evidence of compliance with the insurance coverage required." Additionally,MGL chapter 152, §25C(7)states"Neither the commonwealth nor any of its political subdivisions shall enter into any contract for the performance of public work until acceptable evidence of compliance with the insurance requirements of this chapter have been presented to the contracting authority." Applicants Please fill out the workers' compensation affidavit completely, by checking the boxes that apply to your situation and, if necessary, supply sub-contractor(s) name(s), address(es)and phone number(s) along with their certificate(s) of insurance. Limited Liability Companies(LLC)or Limited Liability Partnerships(LLP)with no employees other than the members or partners,are not required to carry workers' compensation insurance. If an LLC or LLP does have employees, a policy is required. Be advised that this affidavit may be submitted to the Department of Industrial Accidents for confirmation of insurance coverage. Also be sure to sign and date the affidavit. The affidavit should be returned to the city or town that the application for the permit or license is being requested, not the Department of Industrial Accidents. Should you have any questions regarding the law or if you are required to obtain a workers' compensation policy,please call the Department at the number listed below. Self-insured companies should enter their self-insurance license number on the appropriate line. City or Town Officials Please be sure that the affidavit is complete and printed legibly. The Department has provided a space at the bottom of the affidavit for you to fill out in the event the Office of Investigations has to contact you regarding the applicant. Please be sure to fill in the permit/license number which will be used as a reference number. In addition,an applicant that must submit multiple permit/license applications in any given year, need only submit one affidavit indicating current policy information(if necessary) and under"Job Site Address"the applicant should write"all locations in (city or town)." A copy of the affidavit that has been officially stamped or marked by the city or town may be provided to the applicant as proof that a valid affidavit is on file for future permits or licenses. A new affidavit must be filled out each year. Where a home owner or citizen is obtaining a license or permit not related to any business or commercial venture (i.e. a dog license or permit to burn leaves etc.)said person is NOT required to complete this affidavit. The Office of Investigations would like to thank you in advance for your cooperation and should you have any questions, please do not hesitate to give us a call. The Department's address,telephone and fax number: The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations 1 Congress Street, Suite 100 Boston, MA 02114-2017 Tel. # 617-727-4900 ext 7406 or 1-877-MASSAFE Revised 7-2013 Fax# 617-727-7749 www.mass.gov/dia "11�r1 s-7 1x E -` C' ('�hwns:Jnarfharxbverma viewpoln�loud.com/K/recnr„'.X,'547 ------- its roes pNewat Town of North Andover,MA CL : �earcr 20547 -Plumbing Pernik-In Conjunction with a Building Penni[ICammertial or Residential] j I 1} TIMFUNF ® submission received Your request is in progress Jun 8.2016 er 12a4pm we'll let you know of any updates via email.Feel free m check the status at anytime by coming back to this page. oPlumbing Permit Review In Progress OPermit Fee 3' rS OPenn^c t>suam:e < k V 4nptLa Lomtiar. JAMES LAURENCIO 46 COMPASS POINT,NORTH ANDOVER, MA D.ma, BERRY CO Attachments F. -OTT6PDI001F WecuU 8 2016_1 6:29:.PDF L1'1.u,.;font e.1016 Primary Contractor Search for your contractor using the search bar below.Either the Firm's Name or licensee B is required. (���} Nan %lum6•-s Narnt iVcar. , �j � 39PM a� Mrl _ _ 8 f�Q 5�13 @ W(b Eb Wef12:mlt� .2 1�1 Wednesday,Jun 08,2016 12:29 PM The Commonwealth of Massachusetts Department of Industrial Accidents W Office of Investigations d 1 Congress Street, Suite 100 4 Boston,MA 02114-2017 www mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): POWERHOUSE PLUMBING CORP Address: PO BOX 896 City/State/Zip: PLAISTOW, NH 03865 Phone#:6033780020 Are you an employer? Check the appropriate box: Type of project(required): 1. ■❑ I am a employer with 6 4. ❑ I am a general contractor and 1 6. X New construction employees (full and/or part-time).* have hired the sub-contractors 2.ElI am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have g. ❑ Demolition working for me in any capacity. employees and have workers' insurance.$ 9. ❑ Building addition comp.[No workers' comp. insurance p• required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t c. 152, §1(4),and we have no employees. [No workers' 13.❑ Other comp. insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: HARTFORD UNDERWRITERS INSURANCE COMP Policy#or Self-ins. Lic. #:04WECIT2480 Expiration Date:7-28-16 Job Site Address: 48 COMPASS POINT City/State/Zip: N ANDOVER, MA Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 ay a inst the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations the DIA for insurance coverage verification. Ido hereb certify unde the pains an n lties of perjury that the information provided above is true and correct. Si atur Date: 6-6-16 Phone#: 603378 20 Offic l�eo . Do not write in this area,to be completed by city or town official. City or Town: Permit/License # Issuing Authority(circle one): 1.Board of Health 2. Building Department 3. City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: Information and Instructions Massachusetts General Laws chapter 152 requires all employers to provide workers' compensation for their employees. Pursuant to this statute, an employee is defined as"...every person in the service of another under any contract of hire, express or implied, oral or written." An employer is defined as "an individual, partnership, association,corporation or other legal entity, or any two or more of the foregoing engaged in a joint enterprise, and including the legal representatives of a deceased employer, or the receiver or trustee of an individual,partnership, association or other legal entity, employing employees. However the owner of a dwelling house having not more than three apartments and who resides therein, or the occupant of the dwelling house of another who employs persons to do maintenance, construction or repair work on such dwelling house or on the grounds or building appurtenant thereto shall not because of such employment be deemed to be an employer." MGL chapter 152, §25C(6)also states that"every state or local licensing agency shall withhold the issuance or renewal of a license or permit to operate a business or to construct buildings in the commonwealth for any applicant who has not produced acceptable evidence of compliance with the insurance coverage required." Additionally, MGL chapter 152, §25C(7)states"Neither the commonwealth nor any of its political subdivisions shall enter into any contract for the performance of public work until acceptable evidence of compliance with the insurance requirements of this chapter have been presented to the contracting authority." Applicants Please fill out the workers' compensation affidavit completely, by checking the boxes that apply to your situation and, if necessary, supply sub-contractor(s) name(s), address(es)and phone number(s) along with their certificate(s) of insurance. Limited Liability Companies(LLC)or Limited Liability Partnerships(LLP)with no employees other than the members or partners,are not required to carry workers' compensation insurance. If an LLC or LLP does have employees, a policy is required. Be advised that this affidavit may be submitted to the Department of Industrial Accidents for confirmation of insurance coverage. Also be sure to sign and date the affidavit. The affidavit should be returned to the city or town that the application for the permit or license is being requested, not the Department of Industrial Accidents. Should you have any questions regarding the law or if you are required to obtain a workers' compensation policy,please call the Department at the number listed below. Self-insured companies should enter their self-insurance license number on the appropriate line. City or Town Officials Please be sure that the affidavit is complete and printed legibly. The Department has provided a space at the bottom of the affidavit for you to fill out in the event the Office of Investigations has to contact you regarding the applicant. Please be sure to fill in the permit/license number which will be used as a reference number. In addition,an applicant that must submit multiple permit/license applications in any given year, need only submit one affidavit indicating current policy information(if necessary) and under"Job Site Address"the applicant should write "all locations in (city or town)." A copy of the affidavit that has been officially stamped or marked by the city or town may be provided to the applicant as proof that a valid affidavit is on file for future permits or licenses. A new affidavit must be filled out each year. Where a home owner or citizen is obtaining a license or permit not related to any business or commercial venture (i.e.a dog license or permit to burn leaves etc.)said person is NOT required to complete this affidavit. The Office of Investigations would like to thank you in advance for your cooperation and should you have any questions, please do not hesitate to give us a call. The Department's address,telephone and fax number: The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations 1 Congress Street, Suite 100 Boston,MA 02114-2017 Tel. # 617-727-4900 ext 7406 or 1-877-MASSAFE Fax# 617-727-7749 Revised 7-2013 www.mass.gov/da 374 Date. .F/•?/J5. . . .... „ORTry TOWN OF NORTH ANDOVER pF••.ao ,e,ti O PERMIT FOR MECHANICAL INSTALLATION � p F r + SACMUSEt This certifies that�!I :! . . . . C /. • . has permission for mechanical installation. ��!��. .. .. ° . . �`— in the buildings of . . � 7 . ^l . . .7.�`.�°. . . . . • . • . at . . . . . '! �� '!:!L: E?: !• North Andover, Mass. Fee. . . . Lic. No A 5.(.p. . . . . ��� �. . . . . . . . . . . . . . . . . . . . I GAS INSPECTOR WHITE:Applicant CANARY: Building Dept. PINK:Treasurer ��"L b��f� 4� �� Commonwealth of Massachusetts Sheet Metal. Permit Date: `� q- �.� Permit# Estimated Job Cost: $ 3t 0 ob , n 0 Permit Fee: $ Plans Submitted: YES NO Plans Reviewed: YES NO Business License # 196 Applicant License If Business Information: Property Owner/Jo Location Information: Name: J&J Beating & Air Conditioning Street: 17 Arlington St.: Street: _ Pe;n City/Town: Dracut, MA 01826 City/Town: North Andover, MA 01845 Telephone: .97.8-454-8197 Telephone: Photo I.D. required/ Copy of Photo I.D. attached: YES NO scnrrl++urn► J-1 /M-1-unrestricted license J-2 / M-2-restricted to dwellings 3-stories or less and conunercial up to 10,000 sq. it. /2-stories or less Res ideutialf1---2-fafivly IvTulti-family Condo/Townhouses Other Commercial. ' Office Retail Industrial _ Educational Institutional Other Square Footage: under 10,000 sq. ft. ✓' over 10,000 sq. ft. Number of Storics: Sheet metal work to be completed: New Work: �' Renovation: HVAC ✓ Metal Watershed Roofing Kitchen Exhaust System Metal Chimney /Vents Air Balancing Provide detailed description of work to be done: 1-7 rINSURANCE COVERAGE: ve a current liability insurance policy or its equivalent which meets the requirements of M.G.L.Ch..112 Yes 2--No❑ If you have checked Yes, indicate the type of coverage by checking the appropriate box below: A liability insurance policy 2/ Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement. Check One Only Owner ❑ Agent ❑ Signature of Owner or Owner's Agent By checking this box0,I hereby certify that all of the details and Information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and Installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Duct inspection required prior to insulation installation: YES NO Pro>.;ress Inspections Date Comments Final Inspection Date Comments _70I ype of License: FBy ❑ Master❑ Master-Restricted Cityrrown ❑Journeyperson Signature of Licensee Permit it ❑Journeyperson-Restricted4 License Number: Fee$ ❑ Check at www.mass.govldpl Inspector Signature of Permit Approval The Commonwealth of Massachusetts ` Department of Industrial Accidents Office of Investigations ' 600 Washington Street Boston, MA 02111 ww1`v.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Lelzibly Name (Business/Organization/Individual): J & J Heating & Air Conditioning, Inc. Address: 17 Arlington Street City/State/Zip: Dracut, MA. 01826 phone #: 978-454-8197 Are you an employer? Check the appropriate box: Type of project-(requi'red): 1.® I am a employer with 40 4. ❑ I am a general contractor and I •' employees(full and/or part-time).* have hired the sub-contractors 6. New construction 2.❑ I am a sole proprietor or partner- These sub-contractors have listed on the attached sheet. 7,, ❑ Remodeling ship and have no employees '8. ❑ Demolition working for me in any capacity. employees and have workers' comp, insurance.# 9• ❑ Building addition [No workers comp. insurance p' required.] 5. ❑ We are a corporation and its 10.❑ Electrical re'p'airs or additions officers have exercisetheir I L re 3.❑ I am a homeowner doing all work hd h ❑ Plumbing or additions P myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t C. 152, §1(4), and we have no employees. [No workers' 13.❑ Other comp. insurance required.] . *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. tContractors that check this box must attached an additional sheet showing the name of the sub contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number.. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: A.I.M.. Mutual Insurance Policy#or Self-ins.Lic. #: WMZ-8006553-2015 Expiration.Date: 06/02/16 Job Site Address: City/State/Zip: Attach a copy of the workers' compensation policy declaration page (showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a st the violator. Be advised that a copy of this statetnent may be forwarded to the Office of Investigation the DIA r insurance rage verification. I do here fy u er t e pa' and e hryesofperjury that the information provided above is trite and correct. Si nature: Dater 7"5.15 5. 978 54-8197 Phone#: Official use only. Do not write in this area,to be completed by city or town official City or Town: Perin it/Licen s e# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6. Other ' Contact Person: Phone#: ACORD. CERTIFICATE OF LIABILITY INSURANCE FDATE(MM/DD/YYYY) 05/27/2015 PRODUCER 978.887.4900 FAX 978.887.2404 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION Edward F. Sennott Insurance Agency, Inc. ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE 16 South Main Street HOLDER.THIS CERTIFICATE DOES NOT AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. P. 0. Box 457 ,. Topsfield, MA 01983 INSURERS AFFORDING COVERAGE NAIC# INSURED JU Heating & Air Conditioning, Inc. INSURER A: Great American Alliance Ins Co 17 Arlington Street INSURERB: Safety Insurance Company 39454 Dracut, MA 01826 INSURERC: A.I.M. Mutual Insurance Co INSURER D: INSURER E: COVERAGES THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED.NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR DD' POLICY EFFECTIVE POLICY EXPIRATION LTR INSFIN TYPE OF INSURANCE POLICY NUMBER DATE MM DD DATE MM D 0MITSI GENERAL LIABILITY PAC6418906-09 06/01/2015 06/01/2016 EACH OCCURRENCE _ . $ 10000,00( X COMMERCIAL GENERAL LIABILITY DAMAGE TO FIENTE PREMISES Ea occurrence)' $ 300,00( CLAIMS MADE Fx—I OCCUR MED EXP(Any one person) $ 10,00 A PERSONAL&ADV INJURY $ 1,000,00 GENERAL AGGREGATE $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $ 2,000,OO POLICY JECPRO LOC T AUTOMOBILE LIABILITY 24345 SO 06/01/2015 06/01/2016 COMBINED SINGLE LIMIT ANY AUTO (Ea accident) $ 1,000,000 ALL OWNED AUTOS BODILY INJURY X SCHEDULED AUTOS (Per person) $ B X HIRED AUTOS BODILY INJURY $ X NON-OWNED AUTOS (Per accident) PROPERTY DAMAGE $ (Per accident) GARAGE LIABILITY AUTO ONLY-EA ACCIDENT $ FANY AUTO OTHER THAN EA ACC $ AUTO ONLY: AGG $ EXCESS/UMBRELLA LIABILITY UMB6418958-08 06/01/201S 06/01/2016 EACH OCCURRENCE $ 2,000,000 X OCCUR CLAIMS MADE AGGREGATE $ 2,000,000 A $ DEDUCTIBLE RETENTION $ ' $ WORKERS COMPENSATION WMZ-800-8006553-2015 06/02/2015 06/02/2016X TORY ETR AND EMPLOYERS'LIABILITY Y/N C OFFICER/MEMBER EXCLUDED?ECUTIVFANY E.L.EACH ACCIDENT $ 1,000,000 (Mandatory in NH) U E.L.DISEASE-EA EMPLOYE $ 1 000,000 Syes,ECIAL PROVISIONS below describe under E.L.DISEASE-POLICY LIMIT $ 1,000,000 SP OTHER DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES I EXCLUSIONS ADDED BY ENDORSEMENT/SPECIAL PROVISIONS CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,THE ISSUING INSURER WILL ENDEAVOR TO MAIL 10 DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT,BUT FAILURE TO DO SO SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE INSURER,ITS AGENTS OR REPRESENTATIVES. Evidence of Insurance AUTHORIZED REPRESENTATIVE Peter Sennott/LAR ��w ACORD 25(2009/01) ©1,988-2009 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD v COMMONWEALTH OF MASSACI-IUSE.TTS I BOARQ:(JF SHEE:1 1 M04 AL WORKERS ; I SSUES 1 NE. FOLLOWI N I I CGNSC : InSTER—UNRI,STR l CT ` « J. £ 1' HEAT►NG 1AU C:`R KL I,NC i HEWPI NG & nc 17 nRt, NGTON ST E1fZACU ti Mn o182.6- 39 1,6 0,/ 8/16 2111 9 M fAS1SACHUSETTS', J J DRIVER'S` _ LICENSE sa y Vit:. 4aISS'2 9a END 4d NUMBERI. u .q05-03 2011 NONE- S'9965.5879 - Yob EXP .. 3'DOB, 1 rye: ,3 _05-ZZ 016016 QS'2� 1980 - ,--s -'A SGLASS-�12 REST' 15 SEX M. � KD7+.6,09 - " DM NONE KLINE' r 2 ERIC RJ o5- tw 83 LONG DR �^_ / DRACUT,MA 01826.2048, /(. _� 5 DO 05-04-2011 Rev 07.15-2009 '�}' IALTH OF M! S H E E` 'M E`i"<A L"WO:R;K:� ISSUES, THE FOLLOW =L I"CENSE; ;>> AS A BU:S:.:.N,fSSj. . ... EDWARD T AYOTTE J J HEATING,:` QIR CONDITIONING l W ;, 77 ARL�'NGTdN STR. bRA:�uT tfiA 01826 144485 -, 9 Load Short Form Job: 12/46 Compass Point wri htsoft Date: June 16,2015 Entire House By: J&J Heating and A/C 17 Arlington St.,Dracut,Ma 01826 Phone:978-454-8197 Fax:978-454-8615 Email:jeff@jjheatac.com Web:www.jjheatac.com • FIT • • For: Trust Construction 51 Mount Joy Drive, Tewksbury, Ma 01876 Milli ® - • • • Htg Clg Infiltration Outside db (°F) 12 88 Method Simplified Inside db (°F) 70 75 Construction quality Tight Design TD (°F) 58 13 Fireplaces 1 (Average) Daily range - L Inside humidity (%) 50 50 Moisture difference (gr/Ib) 47 28 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual air flow 991 cfm Actual air flow 991 cfm Air flow factor 0.017 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.98 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Garage 484 9180 1505 152 68 Living Room 224 6540 2782 108 127 Dining Room 168 2166 386 36 18 Kitchen 156 0 0 0 0 WIC 54 1050 166 17 8 Closet 54 1050 166 17 8 Master 240 6299 2025 104 92 Mast.Bath 90 3218 979 53 45 Foyer 146 4985 1873 83 85 Room12 30 7 6 0 0 Bath 36 0 0 0 0 Room13 240 4647 2181 77 99 Room14 90 2252 1018 37 46 Room15 160 1450 516 24 23 Room16 328 7100 2313 118 105 Room17 429 7438 4507 123 205 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. i htsoft" 2015-Aug-05 06:58:00 wr g Right-Suite@ Universal 2015 15.0.12 RSU05790 Page 1 ACCK ...ft HVAC\15 St.James way revised Andover Ma.rup Calc=MJ8 Front Door faces: N Room18 108 199 162 3 7 Room19 54 2150 1184 36 54 Entire House 3091 59733 21769 991 991 Other equip loads 0 0 Equip. @ 0.93 RSM 20158 Latent cooling 437 TOTALS 3091 59733 20595 991 991 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoft° 2015-Aug-05 06:58:00 g Right-Suite@ Universal 2015 15.0.12 RSU05790 Page 2 /QCCK ...ft HVAC\15 St.James way revised Andover Ma.rup Calc=MJ8 Front Door faces: N Building Anal SIS Job: 12/46 Compass Point - wrightsoft° y Date: June 16,2015 j Entire House By: J&J Heating and A/C 17 Arlington St.,Dracut, Ma 01826 Phone:978-454-8197 Fax:978-454-8615 Email:jeff@jjheatac.com Web:www.jjheatac.com i For: Trust Construction 51 Mount Joy Drive, Tewksbury, Ma 01876 iIM • • • • Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 70 75 Elevation: 30 ft Design TD (°F) 58 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.5 27.8 Dry bulb (°F) 12 88 Infiltration: Dally range °F) - 15 ( L ) Method Simplified Wet bulb (° - 72 Construction quality Ti ht Wind speed (mph) 15.0 7.5 Fireplaces 1 Average) • --Component Btuh/ft2 Btuh % of load Walls 10.5 29651 49.6 Glazing 32.8 7354 12.3 Doors 22.5 1730 2.9 Ceilings 1.8 3417 5.7 Floors 7.2 13380 22.4 w. Infiltration 1.3 4200 7.0 Ducts 0 0 Piping 0 0 Humidification 0 0 �• Ventilation 0 0 a„ Adjustments 0 Total 59733 100.0 e e • —Component Btuh/ft2 Btuh % of load Walls 3.2 8957 41.1 Glazing 39.0 8728 40.1 Doors 10.3 796 3.7 Ceilings 1.6 2966 13.6 Floors 0 0 0 Infiltration 0.1 321 1.5 Ducts 0 0 Ventilation 0 0 Internal gains 0 0 Blower 0 0 Adjustments 0 Total 21769 100.0 Latent Cooling Load = 437 Btuh Overall U-value= 0.141 Btuh/ft2-°F Data entries checked. i - - wrightsoft' 2015-Aug-05 06:58:00 i Right-Suite@ Universal 2015 15.0.12 RSU05790 Page 1 A—'CA ...ft HVAC\15 St.James way revised Andover Ma.rup Calc=MJ8 Front Door faces: N Component Constructions Job: 12/46 Compass Point wrightsoft p Date: June 16,2015 Entire House By: J&J Heating and A/C 17 Arlington St., Dracut,Ma 01826 Phone:978-454-8197 Fax 978-454-8615 Email:jeff@jjheatac.com Web:www.jjheatac.com ifi= • • For: Trust Construction 51 Mount Joy Drive, Tewksbury, Ma 01876 ® • Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 70 75 Elevation: 30ft Design TD (°F) 58 13 Latitude: 420 N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.5 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Tiht Wind speed (mph) 15.0 7.5 Fireplaces 1 Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss CIg HTM Gain M Btuh/ftz-°F W-°F/Btuh Btuh/V Btu Btuh/ft2 Btuh Wal I s 13AB-Ofcs:Blk wall,stucco ext,8"thk,vermiculite core,1/2" n 547 0.183 17.8 10.5 5766 3.18 1742 gypsum board int fnsh a 842 0.183 17.8 10.5 8875 3.18 2681 S 506 0.183 17.8 10.5 5334 3.18 1611 W 918 0.183 17.8 10.5 9676 3.18 2923 all 2813 0.183 17.8 10.5 29651 3.18 8957 Partitions (none) Windows 1D-c2ov:2 glazing,cir outr,air gas,vnl frm mat,clr innr,1/4"gap, n 36 0.570 0 32.8 1182 17.9 643 1/4"thk;6.67 ft head ht a 76 0.570 0 32.8 2495 59.7 4539 s 112 0.570 0 32.8 3677 31.7 3546 all 224 0.570 0 32.8 7354 39.0 8728 Doors 11 DO:Door,wd sc type n 56 0.390 0 22.5 1258 10.3 579 s 21 0.390 0 22.5 472 10.3 217 all 77 0.390 0 22.5 1730 10.3 796 Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins,1/2" 1854 0.032 30.0 1.84 3417 1.60 2966 gypsum board int fnsh Floors 22A-tpm:Bg floor,heavy dry or light damp soil,on grade depth 176 1.180 0 68.0 11962 0 0 21 1.180 0 68.0 1418 0 0 all 197 1.180 0 68.0 13380 0 0 2015-Aug-05 06:58:00 wrightsoft" Right-Suite@ Universal 2015 15.0.12 RSU05790 Page 1 ACCK ...ft HVAC\15 St.James way revised Andover Ma.rup Calc=MJ8 Front Door faces: N - - �1tSOft-9 Component Constructions Job: 12/46 Compass Point WI'1 p Date: June 16,2015 Garage By: J&J Heating and A/C 17 Arlington St., Dracut, Ma 01826 Phone:978-454-8197 Fax:978-454-8615 Email:jeff@jjheatac.com Web:www.jjheatac.com For: Trust Construction 51 Mount Joy Drive, Tewksbury, Ma 01876 Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 70 75 Elevation: 30 ft Design TD (°F) 58 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.5 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb ( F) - 72 Construction quality Tiht Wind speed (mph) 15.0 7.5 Fireplaces 1 Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft2 Btuh/ft2-°F ftz-°F/Btuh Btu h/ftz Btuh Btuh/ft2 Btu Walls 13AB-Ofcs:Blk wall,stucco ext,8"thk,vermiculite core,1/2" n 198 0.183 17.8 10.5 2087 3.18 630 gypsum board int fish e 72 0.183 17.8 10.5 759 3.18 229 W 198 0.183 17.8 10.5 2087 3.18 630 all 468 0.183 17.8 10.5 4933 3.18 1490 Partitions (none) Windows (none) Doors (none) Ceilings 1613-30ad:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins,1/2" 44 0.032 30.0 1.84 81 1.60 70 gypsum board int fns Floors 22A-tpm:Bg floor,heavy dry or light damp soil,on grade depth 52 1.180 0 68.0 3534 0 0 2015-Aug-05 06:58:00 ti1 rF Wrl 1tSOf Right-Suite@ Universal 2015 15.0.12 RSU05790 Page 2 ACCK ...ft HVAC\15 St.James way revised Andover Ma.rup Calc=MJ8 Front Door faces: N wrightsoftComponent Constructions Job: 12/46 Compass Point Date: June 16,2015 Living Room By: J&J Heating and A/C 17 Arlington St.,Dracut, Me 01826 Phone:978-454-8197 Fax:978-454-8615 Email:jeff@jjheatac.com Web:www.jjheatac.com For: Trust Construction 51 Mount Joy Drive, Tewksbury, Ma 01876 ® - • • • • Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 70 75 Elevation: 30 ft Design TD (°F) 58 13 Latitude: 42°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.5 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Tiht Wind speed (mph) 15.0 7.5 Fireplaces 1 Average) Construction descriptions Or Area LI-value Insul R Htg HTM Loss Clg HTM Gain ftz BtuhN-°F ft2--FBtuh BtuhV Btu Btuh/ft2 Btuh Walls 13AB-Ofcs:Blk wall,stucco ext,8"thk,vermiculite core,1/2" n 70 0.183 17.8 10.5 738 3.18 223 gypsum board int fnsh a 120 0.183 17.8 10.5 1265 3.18 382 all 190 0.183 17.8 10.5 2003 3.18 605 Partitions (none) Windows 1D-c2ov:2 glazing,clr outr,air gas,vnl frm mat,clr innr,1/4"gap, a 24 0.570 0 32.8 788 59.7 1433 1/4"thk;6.67 ft head ht Doors 11 DO:Door,wd sc type n 56 0.390 0 22.5 1258 10.3 579 Ceilings 166-30ad:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins,1/2" 48 0.032 30.0 1.84 88 1.60 77 gypsum board int fnsh Floors 22A-tpm:Bg floor,heavy dry or light damp soil,on grade depth 30 1.180 0 68.0 2039 0 0 2015-Aug-05 06:58:00 wrightsoft' Right-Suite@ Universal 2015 15.0.12 RSU05790 Page 3 ACCK ...ft HVAC\15 St.James way revised Andover Ma.rup Calc=MJ8 Front Door faces: N Component ons t ConstructiJob: 12/46 Compass Point wrightsoft� p Date: June 16,2015 Dining Room By: J&J Heating and A/C 17 Arlington St.,Dracut,Ma 01826 Phone:978-454-8197 Fax:978-454-8615 Email:jeff@jjheatac.com Web:www.jjheatac.com 10:1111 111 IN • in rev, • For: Trust Construction 51 Mount Joy Drive, Tewksbury, Ma 01876 Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 70 75 Elevation: 30 ft Design TD (°F) 58 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.5 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb ( F) - 72 Construction quality Ti ht Wind speed (mph) 15.0 7.5 Fireplaces 1 Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft, Btuh/ft2-°F ft�-°F/Btuh BtuhM Btu Btuh/ftz Btuh Walls 13AB-Ofcs:Blk wall,stucco ext,8"thk,vermiculite core,1/2" a 108 0.183 17.8 10.5 1138 3.18 344 gypsum board int fnsh Partitions (none) Windows (none) Doors (none) Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-30 cell ins,1/2" 36 0.032 30.0 1.84 66 1.60 58 gypsum board int fnsh Floors 22A-tpm:Bg floor,heavy dry or light damp soil,on grade depth 12 1.180 0 68.0 816 0 0 .` Wrlhtsoft" 2015-Aug-05 06:58:00 g Right-Suite®Universal 2015 15.0.12 RSU05790 Page 4 A'_C-K ...ft HVAC\15 St.James way revised Andover Ma.rup Calc=MJ8 Front Door faces: N Component Constructions Job: 12/46 Compass Point wrightsoft- Date: June 16,2015 Kitchen By: J&J Heating and A/C 17 Arlington St.,Dracut, Ma 01826 Phone:978-454-8197 Fax:978-454-8615 Email:Jeff@jjheatac.com Web:www.jjheatac.com For: Trust Construction 51 Mount Joy Drive, Tewksbury, Ma 01876 _01M •I 11MR91 •I Ill • Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 70 75 Elevation: 30 ft Design TD (°F) 58 13 Latitude: 42°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.5 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb ( F) - 72 Construction quality Ti ht O Wind speed (mph) 15.0 7.5 Fireplaces 1 Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss CIg HTM Gain ft2 Btuh/ftp-°F ftl-°F/Btuh Btuh/ft2 Btuh Btuh/ft' Btuh Walls (none) Partitions (none) Windows (none) Doors (none) Ceilings (none) Floors (none) t 2015-Aug-05 06:58:00wri ItSOfRight-Suite@ Universal 2015 15.0.12 RSU05790 Page 5 /�.CI� ...ft HVAC\15 St.James way revised Andover Ma.rup Calc=MJ8 Front Door faces: N Component Constructions Job: 12/46 Compass Point wrightsoft� Date: June 16,2015 WIC By: J&J Heating and A/C 17 Arlington St.,Dracut,Ma 01826 Phone:978-454-8197 Fax:978-454-8615 Email:jeff@jjheatac.com Web:www.jjheatac.com i For: Trust Construction 51 Mount Joy Drive, Tewksbury, Ma 01876 Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 70 75 Elevation: 30 ft Design TD (°F) 58 13 Latitude: 42°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.5 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Tiht Wind speed (mph) 15.0 7.5 Fireplaces 1 Average) Construction descriptions Or Area Ll-value Insul R Htg HTM Loss Clg HTM Gain ft� Btuh/ftz--°F ft�°F/Btuh Btuh/ft2 Btuh MOM Btu Walls 13AB-Ofcs:Blk wall,stucco ext,8"thk,vermiculite core,1/2" w 54 0.183 17.8 10.5 569 3.18 172 gypsum board int fnsh Partitions (none) Windows (none) Doors (none) Ceilings (none) Floors 22A-tpm:Bg floor,heavy dry or light damp soil,on grade depth 6 1.180 0 68.0 408 0 0 2015-Aug-05 06:58:00 -� wrightsoft" Right-Suite@ Universal 2015 15.0.12 RSU05790 Page 6 ACCA ...ft HVAC\15 St.James way revised Andover Ma.rup Calc=MJ8 Front Door faces: N Component Constructions Job: 12/46 Compass Point wrightsoft" Date: June 16,2015 Closet By: JU Heating and A/C 17 Arlington St.,Dracut,Ma 01826 Phone:978-454-8197 Fax:978-454-8615 Email:jeff@jjheatac.com Web:www.iiheatac.com For: Trust Construction 51 Mount Joy Drive, Tewksbury, Ma 01876 Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 70 75 Elevation: 30 ft Design TD (°F) 58 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.5 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Ti ht Wind speed (mph) 15.0 7.5 Fireplaces 1 Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss CIg HTM Gain ftz Btuh/ftl-°F 112-TBtuh Btuh/V Btu Btuh/ft2 Btuh Walls 13AB-Ofcs:Blk wall,stucco ext,8"thk,vermiculite core,1/2" w 54 0.183 17.8 10.5 569 3.18 172 gypsum board int fnsh Partitions (none) Windows (none) Doors (none) Ceilings (none) Floors 22A-tpm:Bg floor,heavy dry or light damp soil,on grade depth 6 1.180 0 68.0 408 0 0 2015-Aug-05 06:58:00 wrightsoft° Right-Suite®Universal 2015 15.0.12 RSU05790 Page 7 ACCA ...ft HVAC\15 St.James way revised Andover Ma.rup Calc=MJ8 Front Door faces: N wrl htsoft Component Constructions Job: 12/46 Compass Point 9 Date: June 16,2015 Master By: J&J Heating and A/C 17 Arlington St.,Dracut, Ma 01826 Phone:978-454-8197 Fax 978-454-8615 Email:jeff@jjheatac.com Web:www.jjheatac.com ar• • • For: Trust Construction 51 Mount Joy Drive, Tewksbury, Ma 01876 Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (OF) 70 75 Elevation: 30 ft Design TD (°F) 58 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.5 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb ( F) - 72 Construction quality Ti ht Wind speed (mph) 15.0 7.5 Fireplaces 1 Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Cig HTM Gain ft� Btuh/ft2-°F ft2-°F/Bwh Btuh/ft2 Bwh Btuh/ftz Bwh Wal I s 13AB-Ofcs:Blk wall,stucco ext,8"thk,vermiculite core,1/2" s 116 0.183 17.8 10.5 1223 3.18 369 gypsum board int fnsh w 135 0.183 17.8 10.5 1423 3.18 430 all 25.1 0.183 17.8 10.5 2646 3.18 799 Partitions (none) Windows 1D-c2ov:2 glazing,cir outr,air gas,vnl firm mat,clr innr,1/4"gap, s 28 0.570 0 32.8 919 31.7 886 1/4"thk;6.67 ft head ht Doors (none) Ceilings 1613-30ad:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins,1/2" 136 0.032 30.0 1.84 251 1.60 218 gypsum board int fnsh Floors 22A-tpm:Bg floor,heavy dry or light damp soil,on grade depth 31 1.180 0 68.0 2107 0 0 wri htsoft" 2015-Aug-05 06:58:00 .,_ 9 Right-Suite®Universal 2015 15.0.12 RSU05790 Page 8 RCCA ...ft HVAC\15 St.James way revised Andover Ma.rup Calc=MJB Front Door faces: N Component Constructions Job: 12/46 Compass Point wrightsoft Date: June 16,2015 Mast.Bath By: J&J Heating and A/C 17 Arlington St., Dracut,Ma 01826 Phone:978-454-8197 Fax:978-454-8615 Email:jefi@ijheatac.com Web:www.jjheatac.com For: Trust Construction 51 Mount Joy Drive, Tewksbury, Ma 01876 Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 70 75 Elevation: 30 ft Design TD (°F) 58 13 Latitude: 42°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.5 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Tiht Wind speed (mph) 15.0 7.5 Fireplaces 1 Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft2 Btuh/ftp°F ft�-°FBtuh Btuh/V Btuh Btuh/ft2 Btu Walls 13AB-Ofcs:Blk wall,stucco ext,8"thk,vermiculite core,1/2" e 27 0.183 17.8 10.5 285 3.18 86 gypsum board int fnsh s 78 0.183 17.8 10.5 822 3.18 248 w 27 0.183 17.8 10.5 285 3.18 86 all 132 0.183 17.8 10.5 1391 3.18 420 Partitions (none) Windows 1D-c2ov:2 glazing,cir outr,air gas,vnl frm mat,clr innr,1/4"gap, s 12 0.570 0 32.8 394 31.7 380 1/4"thk;6.67 ft head ht Doors (none) Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-30 cell ins,1/2" 82 0.032 30.0 1.84 151 1.60 131 gypsum board int fnsh Floors 22A-tpm:Bg floor,heavy dry or light damp soil,on grade depth 16 1.180 0 68.0 1087 0 0 2015-Aug-05 06:58:00 wrightsoft' Right-Suite@ Universal 2015 15.0.12 RSU05790 Page 9 ACCK ...ft HVAC\15 St.James way revised Andover Ma.rup Calc=MJ8 Front Door faces: N Component Constructions Job: 12/46 Compass Point wrightsoft� Date: June 16,2015 Foyer By: J&J Heating and A/C i 17 Arlington St.,Dracut,Ma 01826 Phone:978-454-8197 Fax:978-454-8615 Email:jeff@jjheatac.com Web:www.jiheatac.com For: Trust Construction 51 Mount Joy Drive, Tewksbury, Ma 01876 ! - • • its, • Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 70 75 Elevation: 30 ft Design TD (°F) 58 13 Latitude: 42°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.5 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Tiht Wind speed (mph) 15.0 7.5 Fireplaces 1 Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss CIg HTM Gain ftz Btuh/112-°F ft2-°F/Btuh Bwh/ft2 Btu Btuh/V Btuh Walls 13AB-Ofcs:Blk wall,stucco ext,8"thk,vermiculite core,1/2" a 105 0.183 17.8 10.5 1107 3.18 334 gypsum board int fnsh s 57 0.183 17.8 10.5 601 3.18 181 all 162 0.183 17.8 10.5 1708 3.18 516 Partitions (none) Windows 1D-c2ov:2 glazing,clr outr,air gas,vnl frm mat,clr innr,1/4"gap, a 12 0.570 0 32.8 394 59.7 717 1/4"thk;6.67 ft head ht s 12 0.570 0 32.8 394 31.7 380 all 24 0.570 0 32.8 788 45.7 1097 Doors 11 DO:Door,wd sc type s 21 0.390 0 22.5 472 10.3 217 Ceilings 1613-30ad:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins,1/2" 95 0.032 30.0 1.84 175 1.60 152 gypsum board int fns Floors 22A-tpm:Bg floor,heavy dry or light damp soil,on grade depth 23 1.180 0 68.0 1563 0 0 -�d}�" 2015-Aug-05 06:58:00 .+ "- wrightsoft" Right-Suite@ Universal 2015 15.0.12 RSU05790 Page 10 ACCK ...ft HVAC\15 St.James way revised Andover Ma.rup Calc=MJ8 Front Door faces: N Component Constructions Job: 12/46 Compass Point wrightsoft� Date: June 16,2015 Room 12 By: J&J Heating and A/C 17 Arlington St.,Dracut,Ma 01826 Phone:978-454-8197 Fax:978-454-8615 Email:jeff@jjheatac.com Web:www.jjheatac.com • NO • For: Trust Construction 51 Mount Joy Drive, Tewksbury, Ma 01876 11 - • • • • Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 70 75 Elevation: 30 ft Design TD (°F) 58 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.5 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Tiht Wind speed (mph) 15.0 7.5 Fireplaces 1 Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Cig HTM Gain ft2 Btuh/ftp-°F ftz-°FBtuh Btuh/112 Btu Btuh/ft2 Btuh Wal I s (none) Partitions (none) Windows (none) Doors (none) Ceilings 1613-30ad:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins,1/2" 4 0.032 30.0 1.84 7 1.60 6 gypsum board int fnsh Floors (none) 2015-Aug-05 06:58:00 wrightsoftm Right-Suite@ Universal 2015 15.0.12 RSU05790 Page 11 ACCA ...ft HVAC\15 St.James way revised Andover Ma.rup Calc=MJ8 Front Door faces: N Component Constructions Job: 12/46 Compass Point - - wrightsoft� p Bate: June 16,2015 Bath By: J&J Heating and A/C 17 Arlington St.,Dracut,Ma 01826 Phone:978-454-8197 Fax:978-454-8615 Email:jeff@jjheatac.com Web:www.jjheatac.com For: Trust Construction 51 Mount Joy Drive, Tewksbury, Ma 01876 ! - • • • • Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 70 75 Elevation: 30 ft Design TD (°F) 58 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.5 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Ti ht Wind speed (mph) 15.0 7.5 Fireplaces 1 Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss CIg HTM Gain ft2 Btuh/ft2-°F ftz-°F/Btuh Btuh/ft2 Btu Btuh/ft2 Btuh Walls (none) Partitions (none) Windows (none) Doors (none) Ceilings (none) Floors (none) 2015-Aug-05 06:58:00 wrightsoft' Right-Suite®Universal 2015 15.0.12 RSU05790 Page 12 HCl, ...ft HVAC\15 St.James way revised Andover Ma.rup Calc=MJ8 Front Door faces: N Component Constructions Job: 12/46 Compass Point wrightsoft� Date: June 16,2015 Room 13 By: J&J Heating and A/C 17 Arlington St.,Dracut, Ma 01826 Phone:978-454-8197 Fax:978-454-8615 Email:jeff@jjheatac.com Web:www.jjheatac.com • • • For: Trust Construction 51 Mount Joy Drive, Tewksbury, Ma 01876 Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 70 75 Elevation: 30 ft Design TD (°F) 58 13 Latitude: 42°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.5 27.8 Dry bulb (°F) 12 88 Infiltration: Dally range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Ti ht Wind speed (mph) 15.0 7.5 Fireplaces 1 Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft2 Btuh/ftz-°F ft�-°F/Btuh Btuh/ftz Btu MOM Btu Wal I s 13AB-Ofcs:Blk wall,stucco ext,8"thk,vermiculite core,1/2" s 116 0.183 17.8 10.5 1223 3.18 369 gypsum board int fnsh w 135 0.183 17.8 10.5 1423 3.18 430 all 251 0.183 17.8 10.5 2646 3.18 799 Partitions (none) Windows 1D-c2ov:2 glazing,clr outr,air gas,vnl frm mat,clr innr,1/4"gap, s 28 0.570 0 32.8 919 31.7 886 1/4"thk;6.67 ft head ht Doors (none) Ceilings 1613-30ad:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins,1/2" 240 0.032 30.0 1.84 442 1.60 384 gypsum board int fns Floors 22A-tpm:Bg floor,heavy dry or light damp soil,on grade depth 4 1.180 0 68.0 263 0 0 wrightsoft°' Right-Suite®Universal 2015 15.0.12 RSU05790 2015-Aug-05 06:58:00Page 13 SCA ...ft HVAC\15 St.James way revised Andover Ma.rup Calc=MJ8 Front Door faces: N wri htsoft Component Constructions Job: 12/46 Compass Point 9 Room 14 Date: June 16,2015 Y J&J Heating and A/C 17 Arlington St.,Dracut,Ma 01826 Phone:978-454-8197 Fax:978-454-8615 Email:jeff@jjheatac.com Web:www,jjheatac.com For: Trust Construction ; 51 Mount Joy Drive, Tewksbury, Ma 01876 ® - • • • • Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 70 75 Elevation: 30 ft Design TD (°F) 58 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.5 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Tiht Wind speed (mph) 15.0 7.5 Fireplaces 1 Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss CIg HTM Gain ftz Btuh/ft?°F ft�°F/BWh BtuhN Btuh Btuh/112 Btu Walls 13AB-Ofcs:Blk wall,stucco ext,8"thk,vermiculite core,1/2" e 27 0.183 17.8 10.5 285 3.18 86 gypsum board int fnsh s 78 0.183 17.8 10.5 822 3.18 248 w 36 0.183 17.8 10.5 379 3.18 115 all 141 0.183 17.8 10.5 1486 3.18 449 Partitions (none) Windows 1D-c2ov:2 glazing,clr outr,air gas,vnl frm mat,clr innr,1/4"gap, s 12 0.570 0 32.8 394 31.7 380 1/4"thk;6.67 ft head ht Doors (none) Ceilings 1613-30ad:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins,1/2" 90 0.032 30.0 1.84 166 1.60 144 gypsum board int fnsh Floors (none) 2015-Aug-05 06:58:00 wrightSOW Right-Suite@ Universal 2015 15.0.12 RSU05790 g Page 14 ACCA ...ft HVAC\15 St.James way revised Andover Ma.rup Calc=MJ8 Front Door faces: N Wrl htsoft- Component Constructions Job: 12/46 Compass Point 9 Date: June 16,2015 Room 15 By: J&J Heating and A/C 17 Arlington St.,Dracut,Ma 01826 Phone:978-454-8197 Fax:978-454-8615 Email:jeff@ijheatac.com Web:www.jjheatac.com For: Trust Construction 51 Mount Joy Drive, Tewksbury, Ma 01876 Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 70 75 Elevation: 30 ft 'Design TD (°F) 58 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.5 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Tiht Wind speed (mph) 15.0 7.5 Fireplaces 1 Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft2 Btuh/R2-°F ft2-°FBWh Btuh/ft2 Btu BNh/ftz Btu Wal I s 13AB-Ofcs:Blk wall,stucco ext,8"thk,vermiculite core,1/2" w 90 0.183 17.8 10.5 949 3.18 287 gypsum board int fnsh Partitions (none) Windows (none) Doors (none) Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins,1/2" 160 0.032 30.0 1.84 295 1.60 256 gypsum board int fnsh Floors 22A-tpm:Bg floor,heavy dry or light damp soil,on grade depth 1 1.180 0 68.0 85 0 0 2015-Aug-05 06:58:00 wrightSOW Right-Suite@ Universal 2015 15.0.12 RSU05790 Page 15 "I ...ft HVAC\15 St.James way revised Andover Ma.rup Calc=MJ8 Front Door faces: N �.'On1 onent Constructions Job: 12/46 Compass Point - - wrightsoft- p Date: June 16,2015 Room 16 By. J&J Heating and A/C 17 Arlington St.,Dracut,Ma 01826 Phone:978-454-8197 Fax:978-454-8615 Email:jeff@jjheatac.com Web:www.jjheatac.com s s • For: Trust Construction 51 Mount Joy Drive, Tewksbury, Ma 01876 MITER• • • • Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 70 75 Elevation: 30 ft Design TD (°F) 58 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.5 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Tiht Wind speed (mph) 15.0 7.5 Fireplaces 1 Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft2 Btuh/ft2-°F ft2-TBtuh BtuhtV Btu Btuh/112 Btu Walls 13AB-Ofcs:Blk wall,stucco ext,8"thk,vermiculite core,1/2" n 162 0.183 17.8 10.5 1708 3.18 516 gypsum board int fnsh a 72 0.183 17.8 10.5 759 3.18 229 W 162 0.183 17.8 10.5 1708 3.18 516 all 396 0.183 17.8 10.5 4174 3.18 1261 Partitions (none) Windows 1D-c2ov:2 glazing,clr outr,air gas,vnl frm mat,clr innr,1/4"gap, n 36 0.570 0 32.8 1182 17.9 643 1/4"thk;6.67 ft head ht Doors (none) Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins,1/2" 328 0.032 30.0 1.84 605 1.60 525 gypsum board int fnsh Floors 22A-tpm:Bg floor,heavy dry or light damp soil,on grade depth 8 1.180 0 68.0 557 0 0 2015-Aug-05 06:58:00 ' wrightsoft' Right-Suite@ Universal 2015 15.0.12 RSU05790 Page 16 ACCK ...ft HVAC\15 St.James way revised Andover Ma.rup Calc=MJ8 Front Door faces: N i I Component Constructions Job: 12/46 Compass Point wrightsoft� Date: June 16,2015 Room 17 By: J&J Heating and A/C 17 Arlington St., Dracut,Ma 01826 Phone:978-454-8197 Fax 978-454-8615 Email:jeff@jjheatac.com Web:www.jjheatac.com For: Trust Construction 51 Mount Joy Drive, Tewksbury, Ma 01876 Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 70 75 Elevation: 30 ft Design TD (°F) 58 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.5 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Tiht Wind speed (mph) 15.0 7.5 Fireplaces 1 Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft� Btuh/ft2°F ft2-°FBtuh Btuh/ft2 Btu Btuh/112 Btu Walls 13AB-Ofcs:Blk wall,stucco ext,8"thk,vermiculite core,1/2" n 117 0.183 17.8 10.5 1233 3.18 373 gypsum board int fnsh a 257 0.183 17.8 10.5 2709 3.18 818 w 27 0.183 17.8 10.5 285 3.18 86 all .401 0.183 17.8 10.5 4227 3.18 1277 Partitions (none) Windows 1D-c2ov:2 glazing,clr outr,air gas,vnl frm mat,clr innr,1/4"gap, a 40 0.570 0 32.8 1313 59.7 2389 1/4"thk;6.67 ft head ht Doors (none) Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins,1/2" 429 0.032 30.0 1.84 791 1.60 686 gypsum board int fnsh Floors 22A-tpm:Bg floor,heavy dry or light damp soil,on grade depth 8 1.180 0 68.0 512 0 0 Wrightsoft° Right-Suite®Universal 2015 15.0.12 RSU05790 2015-Aug-05 06:58:00Page 17 ACCA ...ft HVAC\15 St.James way revised Andover Ma.rup Calc=MJ8 Front Door faces: N Component Constructions Job: 12/46 Compass Point wrightsoft� p Date: June 16,2015 Room 18 By: J&J Heating and A/C 17 Arlington St.,Dracut,Ma 01826 Phone:978-454-8197 Fax 978-454-8615 Email:jeff@jjheatac.com Web:www.jjheatac.com Off • F.I I to For: Trust Construction 51 Mount Joy Drive, Tewksbury, Ma 01876 Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 70 75 Elevation: 30 ft Design TD (°F) 58 13 Latitude: 42°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.5 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Tiht Wind speed (mph) 15.0 7.5 Fireplaces 1 Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft2 Btuh/ft2-°F ft2-0F/Btuh Btuh/ft2 Btuh BtuhN Btu Walls (none) Partitions (none) Windows (none) Doors (none) Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins,1/2" 108 0.032 30.0 1.84 199 1.60 173 gypsum board int fnsh Floors (none) wrightsoft' Right-Suite p0 2015-Au Universal 2015 15.0.12 RSU05790 g05 06:58:00 Page 18 RCCA ...ft HVAC\15 St.James way revised Andover Ma.rup Calc=MJ8 Front Door faces: N wri htsoft- Component Constructions Job: 12/46 Compass Point 9 Room19 Byte: June 16,2015 J&J Heating and A/C 17 Arlington St.,Dracut,Ma 01826 Phone:978-454-8197 Fax:978-454-8615 Email:Jeff@jjheatac.com Web:www.iiheatac.com For: Trust Construction 51 Mount Joy Drive, Tewksbury, Ma 01876 Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 70 75 Elevation: 30 ft Design TD (°F) 58 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.5 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb (°F) - 72 Construction quality Tiht Wind speed (mph) 15.0 7.5 Fireplaces 1 Average) Construction descriptions Or Area U-value Insul R li HTM Loss CIg HTM Gain ft2 Btuh/ft2-°F ft�-°FBtuh Btuh/V Btu ROM Btu Walls 13AB-Ofcs:Blk wall,stucco ext,8"thk,vermiculite core,1/2" a 54 0.183 17.8 10.5 569 3.18 172 gypsum board int fnsh s 61 0.183 17.8 10.5 643 3.18 194 all 115 0.183 17.8 10.5 1212 3.18 366 Partitions (none) Windows 1D-c2ov:2 gla;dng,cir outr,air gas,vnl frm mat,clr innr,1/4"gap, s 20 0.570 0 32.8 657 31.7 633 1/4"thk;6.67 ft head ht Doors (none) Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-30 ceil ins,1/2" 54 0.032 30.0 1.84 100 1.60 86 gypsum board int fnsh Floors (none) 2015-Aug-05 06:58:00 wrightsoft" Right-Suite@ Universal 2015 15.0.12 RSU05790 Page 19 ACCK ...ft HVAC\15 St.James way revised Andover Ma.rup Calc=MJ8 Front Door faces: N Pro ect Summar Job: 12/46 Compass Point wrightsoft- y Date: June 16,2015 Entire House By: J&J Heating and A/C 17 Arlington St.,Dracut,Ma 01826 Phone:978-454-8197 Fax:978-454-8615 Email:jeff@jjheatac.com Web:www.jjheatac.com For: Trust Construction 51 Mount Joy Drive, Tewksbury, Ma 01876 Notes: MMME-® - • M I'll lolle Weather: Boston Logan Int'I AP, MA, US Winter Design Conditions Summer Design Conditions Outside db 12 OF Outside db 88 OF Inside db 70 OF Inside db 75 OF Design TD 58 OF Design TD 13 OF Daily range L Relative humidity 50 % Moisture difference 28 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 59733 Btuh Structure 21769 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 59733 Btuh Use manufacturer's data n Rate/swing multiplier 0.93 Infiltration Equipment sensible load 20158 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Tight Fireplaces 1 (Average) Structure 437 Btuh Ducts 0 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 3091 3091 Equipment latent load 437 Btuh Volume (ft3) 27819 27819 Air changes/hour 0.14 0.05 Equipment total load 20595 Btuh Equiv.AVF (cfm) 66 23 Req. total capacity at 0.70 SHR 2.4 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual air flow 991 cfm Actual air flow 991 cfm Air flow factor 0.017 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.98 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-Aug-05 06:58:00 wrightsoft' Right-Suite@ Universal 2015 15.0.12 RSU05790 Page 1 ...ft HVAC\15 St.James way revised Andover Ma.rup Calc=MJ8 Front Door faces: N AED Assessment Job: 12/46 Compass Point wrightsoft, Date: June 16,2015 Entire House By: J&J Heating and A/C 17 Arlington St.,Dracut,Ma 01826 Phone:978-454-8197 Fax:978-454-8615 Email:jeff@jjheatac.com Web:www.jjheatac.com ` •jfi ec nformation For: Trust Construction 51 Mount Joy Drive, Tewksbury, Ma 01876 Location: Indoor: Heating Cooling Boston Logan Int'I AP, MA, US Indoor temperature (°F) 70 75 Elevation: 30 ft Design TD (°F) 58 13 Latitude: 420N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 46.5 27.8 Dry bulb (°F) 12 88 Infiltration: Daily range °F) - 15 ( L ) Wet bulb (°F) - 72 Wind speed (mph) 15.0 7.5 Hourly Glazing Load 14,000-- 12,000-- 10,000-Z 4,00012,00010,000 m 8,000- 6,000-- 4,000-- 2,000-- 0 ,0006,0004,0002,0000 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day /Hwy /Average /A i_ Maximum hourly glazing load exceeds average by 26.7%. House has adequate exposure diversity(AED), based on AED limit of 30%. AED excursion: 0 l3tuh C vuri htsoft0 2015-Aug-05 06:58:00 AC 9 Right-Suite@ Universal 2015 15.0.12 RSU05790 Page 1 �� ...ft HVAC\15 St.James way revised Andover Ma.rup Calc=MJ8 Front Door faces: N