Loading...
HomeMy WebLinkAboutMiscellaneous - 47 BOXFORD STREET 4/30/2018 (3) i BUILDING PERMIT o`�t,VIORTH bo h6 gtio TOWN OF NORTH ANDOVER APPLICATION FOR PLAN EXAMINATION Permit NO: 0� Date Received 0 . . y r � ran� HU Date Issued: Y IMPORTANT:Applicant must complete all items on this page MRP f K Pnnt RPERT�'O1AINER 5' �+=;�c A f ,� , h t 4 w.l.-�' ,wR• v r ri.. s iT � re Yh,." 'Ss .�. 1 g � h. t'b� r r*; j- •1 a C1A0' �PAR � � flN#lG 7�JTI�CT NisoncUis#r�ct' gyres y ` = hop Village dies ,T rio =Mac ine � TYPE OF IMPROVEMENT PROPOSED USE . Resi Non- Residential New Building _ One famil dd�ition Two or more family industrial A tion No. of units: Commercial Repair, replacement Assessory Bldg Others: Qpmolition Other Septic Nw ell �Flondpla,n ?r ° letlands � Waters#�ed�©isfrt - _ ; -.r Tater ewefn DESCRIPTION OF WORK TO BE PREFORMED: -L,c 2--O Identification Please Type or Print Clearly) OWNER: Name: �Aiti� S.-\��� Phone: Address: COTRAGTOR Name _ = Phone ` a tX S�perv�sor' kConstrudtioiLkeraser Exp Da#e Y f Home Improve � � rt ARCHITECT/ENGINEER dos Phone: Address: .o1•vw Reg. No. FEE SCHEDULE:BULDING PERMIT:$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $ V, U V L) FEE: $ ) Check No.: F �-J t Receipt No.: 20: NOTE: Persons contracti with unregistered contractors do not have ac ss tote ty fu Signature' S'gna"tire of contracto- - Building Department The following is a list of the required forms to be filled out for the appropriate permit to be obtained. Roofing, Siding, Interior Rehabilitation Permits ❑ Building Permit Application ❑ Workers Comp Affidavit ❑ Photo Copy Of H.I.C. And/Or C.S.L. Licenses ❑ Copy of Contract ❑ Floor Plan Or Proposed Interior Work ❑ Engineering Affidavits for Engineered products { NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit Addition Or Decks ❑ Building Permit Application ❑ Certified Surveyed Plot Plan ❑ Workers Comp Affidavit ❑ Photo Copy of H.I.C. And C.S.L. Licenses ❑ Copy Of Contract ❑ Floor/Crossection/Elevation Plan Of Proposed Work With Sprinkler Plan And Hydraulic Calculations (If Applicable) ❑ Mass check Energy Compliance Report (If Applicable) ❑ Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit New Construction (Single and Two Family) ❑ Building Permit Application ❑ Certified Proposed Plot Plan ❑ Photo of H.I.C. And C.S.L. Licenses ❑ Workers Comp Affidavit ❑ Two Sets of Building Plans (One To Be Returned) to Include Sprinkler Plan And Hydraulic Calculations (If Applicable) ❑ Copy of Contract ❑ Mass check Energy Compliance Report ❑ Engineering Affidavits for Engineered products NOTE: All dumpster permits require sign off from Fire Department prior to issuance of Bldg Permit In all cases if a variance or special permit was required the Town Clerks office must stamp the decision from the Board of Appeals that the appeal period is over. The applicant must then get this recorded at the Registry of Deeds. One copy and proof of recording j must be submitted with the building application Doc:INSPECTIONAL SERVICES DEPARTMENT:BPFORM07 Revised 2.2007 E Location �a�C vA r tit No. ?� Date 16 - t5' 0-:l- MaRTM TOWN OF NORTH ANDOVER i y ♦ i Certificate of Occupancy y � '► _ CM Building/Frame Permit Fee $� i Foundation Permit Fee $ , Other Permit Fee $ TOTAL $ Check # a S 20711 v Building Inspector I =PlansSubm Plans Waived Certified Plot Plan Stamped Plans GE DISPOSAL Public Sewer Tanning/Massage/Body Art Swimming Pools Well Tobacco Sales Food Packaging/Sales Private(septic tank,etc. Permanent Dumpster on Site THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF - U FORM DATE REJECTED DATE APPROVED PLANNING & DEVELOPMENT COMMENTS ATE REJECTED DATE APPROVED CONSERVATION COMMENTS " DATE REJECTED DATE PROV HEALTH COMMENTS oe� �`r- a_�.��rd..c�� ��� �- �n 1�� -�o-� ►�� i Zoning Board of Appeals: Variance, Petition No: Zoning Decision/receipt submitted yes Planning Board Decision: Comments Conservation Decision: Comments Water & Sewer Connection/Signature&Date Driveway Permit Located at 384 Osgood Street IRE'DEPARTMENT TempDurrpster on site fires °no ;Located at 124 Mam Street i m Fire Departme itsignature date COMMENTS Dimension gJ Number of Stories: Total square feet of floor area, based on Exterior dimensions. Total land area, sq. ft.:_ ELECTRICAL: Movement of Meter location, mast or service drop requires approval of Electrical Inspector Yes No DANGER ZONE LITERATURE: Yes No MGL Chapter 166 Section 2 1 A—F and G min.$100-$1000 fine NOTES and DATA— For department use) ❑ Notified for pickup - Date Doc.Building Permit Revised 2007 x•10RTH Town of '� :. - Andover -No. o . Sas - C 0 Aodover, Mass.LAKE ' COCHICHEWICK 1' r �Ao Pavy RATED P` �y `r BOARD OF HEALTH Food/Kitchen PERMIT T Septic System �` 1 I THIS CERTIFIES THAT....:. ............................... l/� ............................. BUILDING INSPECTOR .............................................. Foundation has permission to erect........................................ buildings on..4vv ....... Rough to be occupied as.IZ20.....��, t �n P A� .... �....fii....�!��........... ..........*4...QR......................................:.................. Chimney provided that the person accepting this permit shall in every respect conform to the terms of the application on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection, Alteration and Construction of Final Buildings in the Town of North Andover. PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough qjb * PERMIT EXPIRES IN 6 MONTHS Final UNLESS CONSTRSTARTS ELECTRICAL INSPECTOR. Rough ....... ......................................... Service INSPECTOR BUILDING Final Occupancy Permit Required to Occupy Building GAS INSMCTOR Display in a Conspicuous Place on the Premises — Do Not Remove Rough Final No Lathing or Dry Wall To Be Done Until Inspected and Approved by the Building Inspector. FIRE DEPARTMENT Burner Street No. SEE REVERSE SIDE Smoke Det. September 19, 2007 Susan Y. Sawyer, REHS/R.S. Public Health Director North Andover Board of Health 1600 Osgood Street North Andover, Ma. 01845 Re: 47 Boxford Street North Andover, Ma. Construction of Porch Addition Dear Susan: This letter is being written in regards to proposed construction of a porch addition for my above referenced property. I understand that the construction of this addition requires I install a new subsurface sewage disposal system, the plans for which have been approved. I hereby agree that construction of the septic system will commence prior to June L, 2008 and will be completed no later than August 1, 2008. This is for your information and should you have any questions, please contact me at my residence phone# 978 725-8858. Thank you. Sincerely, 4 � Peter J. Sullivan Phone: (603) 642-8910 Fax: (603) 642-8952 Excavators Inc. 45 Little River Rd. Kingston, NH 03848 CONTRACT DATE: September 18, 2007 SUBMITTED TO: Peter Sullivan 47 Boxford St. North Andover, MA 01845 JOB: Septic system installation. PLANS: New England Engineering Services, Inc. July 3, 2007—2 pages, no revisions. CONTRACT PRICE(circle one): $30,902.00 ($31,702.00 with Addition #1 -see below**) CONTRACT PRICE INCLUDES: 1 —Strip and pile topsoil. 2—Pump and crush existing septic tank. 3 —Supply and install all � materials for completion of septic ss tem. Also includes pump and controls, retaining wall, electrical wiring, and cost of permit. 4—Reloam, rake, and hydroseed all disturbed areas. CONTRACT PRICE DOES NOT INCLUDE: 1 —Inside plumbing. 2—Engineering costs. 3 —Tree removal. 4—Any damage to driveway. 5—Blasting or removal of ledge, if encountered. ADDITION#1: ($800.00) 1 —Re-plumb sewer pipe in basement. CONTRACT TERMS: 1 —Work to be performed in Spring of 2008. 2—Forty percent (40%) of total contract amount due upon installation of septic sand and tank. 3 —Balance of contract due upon final grade and inspection by Town. Respectfully submitted t- William T. Sawyer, Pre ent Arco Excavators, Inc. Accepted by y2 Printed name and date i�'�laZ j �u�t'eyAA a o ROAD CONSTRUCTION — SEWER &WATER LINES — SEPTIC SYSTEMS Your effort to provide a properly functioning septic system for your dwelling is greatly appreciated. The Health Department may be reached at 978-688!-9540 with any questions you may have. Sincerel , usan Y. Sawyer, HS/ Public Health Director Encl: list of licensed septic system installers Form 9B for owner records Cc: New England Engineering Services 1600 Osgood Street,North Andover,Massachusetts 01845 Phone 978.688.9540 fax 978.688.8476 Web www.townofnorthandover.com vtoRTH q X61 0 o � O cocMcwcwrta �. �9SSACHUS���� PUBLIC HEALTH DEPARTMENT Community Development Division August 9, 2007 Peter Sullivan 47 Boxford Street North Andover, MA 01845 RE: Septic System Design, 47 Boxford Street,North Andover,Man 106A,Lot 64 Dear Mr. Sullivan, The North Andover Board of Health has completed the review of the septic system design plans, for the above referenced property, submitted on your behalf by New England Engineering Services, dated August 8, 2007. This plan has been approved. The approval includes a Local Upgrade Approval as found attached. This plan is valid for two years from the date of this approval. The design has been approved for use in the construction of an osite septic system for a 3- bedroom house (maximum 7-room). During this time, a licensed septic system installer must obtain a permit and complete this work, and a Certificate of Compliance be endorsed by the installer, designer and the Town of North Andover. In the event an imminent health problem such as sewage backup into the dwelling is occurring,the North Andover Board of Health may reduce the time period for which this plan is valid. This approval is subject to the following conditions: 1. If site conditions are found in the field to be different from those indicated on the design plan and/or soil evaluation, the originally issued Disposal System Construction Permit is void, installation shall stop, and the applicant shall reapply for a new Disposal Systems Construction Permit. 2. It is the responsibility of the applicant and/or the applicant's septic system designer, septic system installer or other representative to ensure that all other state and municipal requirements are met. These may include review by the Conservation Commission,Zoning Board, Planning Board, Building.Inspector, Plumbing Inspector and/or Electrical Inspector. The issuance of a Disposal System Construction Permit shall not construe or imply compliance with any of the aforementioned requirement. 1600 Osgood Street,North Andover,Massachusetts 01845 Phone 978.688.9540 Fox 978.688.8476 Web www.townofnorthandover.com BOXFORD STREET CERTIFIED PLOT PLAN 125.00' LOCATED /N NORTH ANDOVER, MASS. 14 SCALE:1"=40' DATE:2/05/2007 #47 Scott L. Giles R.P.L.S. EXIST. HSE. Frank. S. Giles R.P.L.S. FND. 31 50 Deer Meadow Road North Andover, Mass. PROP. ADD. -�- 32'+/- LOT 11 45922 S.F. co N Z ti U O co N O RNF 1 CERTIFY THAT p`AN OF OFFSETS SHOWN ARE FOR THE USE THE OFFSETS SCO OF THE BUILDING INSPECTOR ONLY 4� SHOWN COMPLY AND SUCH USE IS FOR THE �t WITH THE ZONING . 13972 ,c, DETERMINATION OF ZONING s ISTERE� Q BYLAWS OF -CONFORMITY OR NON-CONFORMITY LL WHENBUILT WHEN CONSTRUCTED. 2�/ ow 1-7 • M o • 169 Boxford Street North Andover,• 9 8-688-5335A01845 PH FAX:978�88-7207 Building Contractor • 4 Proposal To: Peter&Betsy Sullivan 47 Boxford Street All Home improvement Contractors and Subcontractors engaged in home improvement contracting,carless North Andover, Ma. 01845 specifically exempt from registration by Provisions of chapter 142A of the general laws,must be registered with the Commorrweallh of Massachusetts.Inquiries about registration and Status should be made to the Director,Home Improvement Contract Registration,One Ashburton Place, From: Kevin Murphy Room 1301,Boston,MA 02108.(617)-727 8598 CC: Date: 4/24/2007 .lob: Screened Porch/Deck Date of plans: 2/07 Architect: Steve Foster Location: Same Section 1-Work Schedule Contractor will begin the work or order the materials before the third day following the signing of this agreement, unless specified here in writing contractor will begin work on or about 5/15/07. Barring Delay caused by circumstances beyond Contactors control,the work will be completed by 7/30/07.The owner hereby acknowledges and agrees that the scheduling dates are approximate and that such delays that are not avoidable by the Contractor shall no be considered as violations of this agreement. Section 11-Warranty The Contractor warrants that the work furnished hereunder shall be free from defects in materials and workmanship for a period of 1 year following completion and shall comply with the requirements of this Agreement. In the event any defect in workmanship or materials, or damage caused by the Contractor, his subcontractors, employees or agents, is discovered within one year after completion of any job, including deanup,the Contractor shall,at his own expense,forthwith remedy, repair correct,replace,or cause to be remedied,repaired,or replaced, such damage or such defect in materials or workmanship. The foregoing warranties shall survive any inspection performed in connection with the agreed-upon work. Section 111-Scope of Work Page 2 of 4 Building Contractor 169 Boxford street North Andover,MA 01845 PH:978688-5335 FAX 97868 )OM General Building permit will be provided by contractor. Owner to provide building plans and certified plot plan. No allowance has been made for conservation approvals. No allowance has been made for any title five inspections or board of health approvals. Foundation Footings for room will be 12"x48"as shown on plans. Building All frame, roof, and siding materials will be supplied to meet code/as shown on plans. Floor joists will be 2x12, walls will be 2x4, rafters will be 2x10. All floor, wall, and roof sheathing will be plywood ( 3/4 on floor, 1/2 on walls, 5/8 on roof ) . Roof shingles will match existing. Ice and water sheild will be installed at all roof edges. Siding will be white cedar shingles over Tyvek or equivalent. Twelve Anderson TW400 series doublehung windows will be supplied and installed. Two Anderson Frenchwood inswing patio doors will be supplied and installed. Patio doors will have one active and one stationary door. Two decks will be built as shown on plans. Decks will have pressure treated frames,trex decking,and mahogany railing. Electrical Electrical work required to wire addition to meet code will be provided. Six recessed lights have been included. Additional lights can be added at a cost of$75 per light. Phone/cable /computer lines will be roughed in by electrician, to be connected by their service provider at owner's expense. Any surface mounted fixtues to be supplied by owner(ceiling fan, outside fixtures) Heating/Air Conditioning No allowance has been made for any heating or air conditioning. Plumbing No allowance has been made for any plumbing. Insulation Roomm will be insulated to meet code. (R-30 in floor, R-13 in walls, R-30 in ceiling) Plaster Walls and ceilings will be blueboarded and skimcoat plastered. Walls will be smooth,ceiling to match existing. Interior Trim/Doors Interior trim will be supplied and installed to match existing. Other Allowances All construction debris will be disposed of by contractor. Kevin wunn? ny Page 3 of 4 Building Contractor 169 Bo)dord Street North Andover,MA 01845 PH:978-688-5335 FAX:978-688-XXXX Items Not Included There have been no allowances made for any painting, flooring, transom windows above french door, round columns,or overhangs. • mevfim munphy Page 4 of 4 St(Uding Contractor 169 Boh6ord Street North Andover,MA 01845 PH:978-88-5335 FAX 978-688-)000( Section IV-Price Schedule We hereby propose to fumish material and labor—complete in Accordance with above specifications for the sum of... ... ... ... ... ... ... ... ... ... ... ....$ 40,000 Payment to be made as follows: Percentage/Item Description Amount 1 Permit obtained $2000 2 Roof framing complete $15,000 3 Siding /windows installed $10,000 4 Plastering complete $10,000 5 Job 100% complete $3000 Total 5 $40,000.00 Notice:No agwrnent for Home improvement contracting work shall require a down payment(advance deposit)of more that one-third of the total contract price of the total arnount of all deposits or paynreMs which the contractor must make,in advance,to order and/or otherwise obtain delivery of special order materials and equipment,whichever is greater Contractor: Kevin Murphy 169 Boxford Street No.Andover, MA 01845 Registration No: 101874 Section V—Acceptance Acceptance of Proposal—I have read this document and accept the prices,specifications, and conditions stated. I understand that upon signing,this proposal becomes a binding contract.You are authorized to do the work as specified. Payment will be made as outlined above. You the buyer may cancel this transaction at any time prior to midnight on the third business day after the date of this transaction cancellation must be done in writing DO NOT SIGN THIS CONTRACT IF THERE ARE ANY BLANK SPACES Signature tijZ, Date, Signature Date r f tlORTy 9 O t�t�eo ,6�ti0 OmA ��SSACHUSEt�y CONSERVATION DEPARTMENT Community Development Division September 28, 2006 Mr. &Mrs. Peter Sullivan 47 Boxford Street North Andover, MA 01845 47 BOXFORD STREET North Andover Construction of a Screened Porch Conservation Conditions of Approval,NACC 421 On September 19, 2006 a small project review (section 4.4(K) of the North Andover Wetland Regulations) by Mr. &Mrs. Peter Sullivan (homeowners) of 47 Boxford Street, North Andover. The proposed work includes constructing a 12'x20' (240s.f screened porch attached to an existing single- family house within the Buffer Zone to an adjacent Bordering Vegetated Wetland (BVW). The screened porch will be built on 6 sonotubes approximately 84' from the wetland resource area, at its closest point and shown on the attached sketch.All construction activities will be conducted within existinglawn and will be performed b hand. P Y During the September 27, 2006 public meeting, the North Andover Conservation Commission ACC voted unanimous) 4-0 vote to issue a small ro'ects a roval for the construction of the Y ( ) p l 1?P screened porch at 47 Boxford Street,North Andover. This permit is being issued to the being issued the property owner,who is ultimately responsible for the actions and / or work performed at the above referenced property. As the property owner,you must ensure that all of the requirements outlined in these documents are adhered to. Failure to comply with the requirements outlined in this permit will result in future enforcement action. The followingconditions are mandato under this small ro ects ermit. mandatory p 1 P Conditions: 1. Since the proposed earthwork will be dug by hand, as well as j he existing flat topography and distance to wetland resource area, erosion controls are not rerired. However, the NACC reserves the right to impose the use of erosion controls (hay bales & / or silt fence) if the site exhibits erosion, or any noticeable degradation of surface water quality discharging from the site. Should the erosion control be required by the NACC or the Conservation Department, they 1600 Osgood Street,Building 20,Suite 2-36,North Andover,Massachusetts 01845 Phone 978.688.9530 fax 978.688.9542 Web www.http://www.tdwnofnorthandover.com/conservel.htm shall be installed within 48 hours of the request. The erosion control barrier will be properly installed (silt fence trenched 4—6-inches into the ground,backed by double-staked hay bales) and shall be inspected and approved by the Conservation Department. These temporary erosion control measures shall remain intact until all disturbed areas have been permanently stabilized to prevent erosion. All erosion prevention and sedimentation protection measures found necessary during construction shall be implemented at the direction of the Department or the NACC. 2. Accepted engineering and construction standards and procedi res shall be followed in the completion of the project. 3. Upon completion of the approved project and site stabilization, the Conservation Department shall be contacted to conduct a final inspection. 4. This small projects permit shall expire on November 1,2607 Should you have any question or comments regarding the contents of this letter,please do not hesitate to contact the undersigned at 978.688.9530 at your earliest convenience. Thanking you in advance for your anticipated cooperation with this matter. Respectfully, NORTH AND VER C RVATION DEPARTMENT: Pamela A. Merrill Conservation Associate 1600 Osgood Street,Building 20,Suite 2-36,North Andover,Massachusetts 01845 Phone 978.688.9530 Fax 978.688.9542 Web www.http://www.to,wnofnorthandover.com/conservel.htm The Conwonwea//b of MattaeeAwa►ft J*peMMnt of/ndAwrMl Acci*,vts a441y QA7ce of lnveshgstions 600 W"kin#ex Street � Nosi►a., MA 021 11 i www.nwss gorldle Workers`Compensation Insurance AMdavit: BuildergContractors/Ekdnciana/Piumbers !s P t NatT11C tt�trxiael)�tanirutiein/Incfividtwl;: ` Address: City/State/Zip: o t kt C phone Are you ar empleyer?Check the appirepriate bot: -- I. I em a with 4. I ern a 11 Type os'Mr9*t(rapired�): V, e�Ple)w .._. ❑ general contractor and I i "oploye*s(Bili and/or part-time).' have hired the sub-c ontractom 6. ❑ New eon3trnwtion 2.[] t am a sole proprietor or partner- listed on the agached sheet, ; 1. ( Rrrnodeling ship enol have no employees These%Ub-contraet�on have y forms a. llernolition airy capacity. workers'comp. insurance. jNo wolken'comp.ir"Mrice 5- ❑ We arca tion and its 9' 5k8uilding addition corporation �rhlld.j officers have exercised their 10•❑ Eketrical repairs or additions 3.Q l am a homeowner doing,all work right of exemption per MGI. t i.[]plumbing re�rairs or adlitinns atyaelf.(No wMitem,comp. C. 152.§1(4),and we have no inottrrtnce rtiquired.l* mrtpbyees. rNa workers• 12.0 Roof r"irs camp, insurenee required.) 13[]Qtlner _..__..._ i :Arty M+lM M rt o dM des hm d)MW aha tul taut rhe WOW below 4mwi"x(heir wsxkers'aua�paegip��;� inrrnm>tlicxi. -�--- � irtntteawaerf whe ftl6aNr(lairwA4tf vii in/imaNtr=Miy ae No wad"W Man Ince ' dltfR r11M 6na rtUlal rNfrCMed M ardifieMl fMet rice tNe*elute oMwde frt6rnK a nt w dl�vit indicat*each. obvmnubtsaadlfteira, � R�IiCy inhwManoe � fh�rg Aw 408p"go am h pmwWIWAers't�ayrpr�erarrlttiarr hKarnruce fdw AV a fey��aMr Insurance Company r' CV Policy#or Self-ins. Lic. M:- VL*,-C._ 3 `V, . dab Sire Addtts: Al AtW6 a gory or#*wedltear•ssMpea"#j&r polity declandl*w pate(showing the pogcy wanaber and cxpiratiauu date). Failure to WUM e6VMge as required under Section 25A of W X c. 152 can lead to the imposition of criminal penalties of a rite up to S$-M-00 uWar cure-year atWis0nm*i ,as wcii as civil pemitie's in the kwrn uFe STt)p Wt)*K ORDER and a fare Of up to$250.00 a day agltinet the vioialor. 8e advised that a copy of this statement tray be Forwarded to the()Rice of In"Itigatiou�ta of the DIA for insurance coverage verification. Ido !who ! rN! ti urea rbe iejofwwNew prgtlfi„Ia1�vMe/r!rare wn►d�'enrcr C' (7 t X11/Aw W*. Aur raw trru►ae in I"anew.M AW coa rR[rmw M eltp or Mnw adgkifid City or Town: PermititAtonse r ,I - "rg AwMarity f kvk*trek 1. Board of f aMb 3.atrN lirtR D"w howat 3.City/Town Ckrit 4.Eketrieai lnsp&dor �.PNnrwbitg laspeetsr 66 l3 dmw COMM4 ferns. Ph*"N: 08/27/2007 09:58 FAX 19788839147 X.P.ROBERTS INSURANCE Q001/002 AWRD- CERTIFICATE OF LIABILITY INSURANCE aTelf�onMnh �oaucan Two p[RTiMATE 0 r A IMArrER�IaIPOR 7i2o pi 11.P. s =8 A= INC ONLY AND COW4W NC RIOHU t TME t TWTE 1060 08g+0AQ Htt^�t HOLWACTMA THIS CERTIFICATE DCL'8 � AVWWW EXTEND OR north Andover, 101 01845 7 OWPIM APPOROM C0VWt4W �IAICfI' l0!vnq lduRm jmzv o & a A amm LINA 8sur M{auRMA B; ulwicum MUM 169 80EZ mi"m STFAW ViRm c: QOM 91MOV21t, Nh 01945 MMxlRae a, HlaMR E: Thi1E POl1C1t:8 of a tlQrEp eE1 OMM HfnvE 6EEN Ms=TonewntRww&=MIOVEFMTHRPOLLftypeWDODICATM. �oxro ANY RlMptEW T IM OR CONWM OF ANY OWRACT ON OTHER DOCUMENT WITH PWAPECT TO WHICH Tai16 CERTMgGITO MAY SWOM OR MAY Po"m THE WURMW AFP==8Y THE POW=088CREM HMN M AULIEBT TO ALL THE TENf^OiG.U9iDNS AND CONDITION!,OF SUCH POLIOOAGGIaNAYMLMr$SNO MIMYMAVWNMREaLowe1'PM *AWM faOL CY NLWW IflIMTa (Ml IMQW ttv 20 : a�N.tJAMMJTY �1•••'— •• A �J C.P20060868 11/22/06 11/22/07 NuAADVWA*V a 1,000,0 s I�ILfOATfE(MTf7PPllq OM rRoolwra-�PAoo . mLL-f we AWOMOBLE LAOMUTY AWf AUM MIND `""� a 500,000 �owNl�Aurva f�a,0ou.�aAuroe �� i 8 NROAMOS 7AN0277013608 1/23/07 1/23/08 NONourNMnsurOs , s q° s *f11f:Ard!! f 1Y' AM *&V-&AAWwew e AWAM QQTT��RR�yyy aAACC >1 pMAOdwY: AMO EMMMMOREJA UROUTY EACH i OOOUfI C�AMIaMADE AOOIRMTE a MIONI�IdC01R61�ATIONAND a _ O � 11p11C703876 7/1/06 7/i/O? ra.EncMr r 80826 7/I/07 7/1./08 a.Ln�seAeE.ea ; emm . Q"R POLWY Lam a NOR /COCI1TiDNBtvElptxlftpil�Appgasyp10d18dr�ItTf } O� MINWATE TOS 0w Nown Ammm, 1& G"O"ANY OF TW M0A DlWAWa PMV"W CANe6=ONION Tm O PMtAT" = D1G ft DA'%WOMOF,TW Ia*jM MIagM Vey iM DL%VOR TO MRA,10 OAYa 1600 08Qt'm 822I1 m NaTloe TO IM CffIIiTI«IOATE M=Ft man YO Tm&WT.aur FAMAm Tp 00 9O m+su >s10�B AIIDC�{►iR, M 02846 W NO 0000ATM OR MUM OP ANY KM WM?1!E ng M)f!lM OR TATMW AUTO Rfg wt>lID�elioo'If�olq OAt2lRD�RPORATIOIMlpy i .` '� .. . r ,r ' ;. � .. � � �.. �� . •_� �' • _ ! NORTH ANDOVER BUILDING DEPARTMENT Tel: 978-688-9545 DEBRIS DISPOSAL FORM In accordance with the provision of MGL c 40 S 54, a condition of Building Permit at: �� _ �' , is that the debris resulting from this work shall be disposed of in a properly licensed solid waste disposal facility as defined by NIGL , 11, S 150 A. Also, note Permits are required under Fire Prevention laws Chapter 148 Section I OA. The debris will be disposed of in: Location of Facil ty) Signa o Permit Applicant Fire Department Sign off; _ K./Q Dumpster Permit Date r -_. Board of Building Regulations and Standards HOME IMPROVEMENT CONTRACTOR Registration: 101874 Expiration:=6/29/2008 Type Individual KEVIN MURPHY`+ Kevin Murphy, 169 Boxford St N.Andover,MA 01845 Deputy Administrator `0�°°f S"�i� u`7'a'�io�an an arils - '-onstruction.Supervisor-License j License: CS 53099 Birthdate:>6/29/1967 Exptratron=6fW9/2009 Tr# 14120 �,� R'astnctaon* -00 KEVIN'W MURPHY, r Y 169:BOXFORD ST N ANDOVER,MA 01845 ' Commissioner r ----------- ---------- ' I I I I NEW CONCRETE PIERS OUTLINE OF NEW j FOR DECK ABOVE j DECK(ABOVE) I I I I i I I !! _______________________________________e EXISTING BRICK MASONRY 1 RETAINING WALL PLANS FOR I Sullivan Residence NEW 24"DIAMETER 47 Boxford Street POURED CONCRETE North Andover MA PIER FOUNDATIONS � DATE:2/26/07 V.I.F. LOCATIONS OF PIERS AT ADJACENT TO EXISTING BRICK RETAINING WALL. t i� f " ALIGN CONCRETE PIER WITH 4 X 4 WOOD POST I SUPPORTS ABOVE l �f BASEMENT PLAN .N�_OUTLINE OF NEW ADDITION(ABOVE) I PO PO I I I I I I I I I I I I I EXISTING CONCRETE BLOCK FOUNDATION I I I 1 I j OUTLINE OF EXISTING STUDY I i �i r ----------- ---------- I I I I NEW CONCRETE PIERS OUTLINE OF NEW FOR DECK ABOVE j DECK (ABOVE) I I I I I I I EXISTING BRICK MASONRY RETAINING WALL PLANS FOR f Sullivan Residence NEW 24" DIAMETER 47 Boxford Street POURED CONCRETE North Andover MA PIER FOUNDATIONS V.I.F. LOCATIONS OF PIERS SCALE:1/4"=V-0" DATE:2/26/07 AT ADJACENT TO EXISTING BRICK RETAINING WALL. ALIGN CONCRETE PIER WITH 4 X 4 WOOD POST SUPPORTS ABOVE ' BASEMENT PLAN OUTLINE OF NEW ADDITION (ABOVE) I I I I I I I I I I I I EXISTING CONCRETE BLOCK FOUNDATION I I I I j OUTLINE OF EXISTING STUDY I ' I L--------- --------- I � I�ZONING SETBACK BUILDER/OWNER CONFIRM I CONFIRM � I STAIRS TO FINISH GRADE I I 1 I I � I STEP DOWN TO NEW DKK I I I I RAILING i T FIXED SIDELIGHTS -vur�s wa - ID E TO MATCH PATIO DOOR i Sullivan Residence 47 Boxford Street North Andover, MA 1 � FULL HEIGHT 4 X 4 WOOD POST I I I 1 I I PATIO DOOR UNIT ' 1 "ANDERSEN—FRENCHWOOD' I I FG 5468 EXISTING I j j I BRICK 1 I I '--RIDGE BEAM j WALL? I 1 1 DECK TO FOLLOW i I I (ABOVE) 1 "OUTLINE"OF BRICK 1 RETAINING WALL PORCH BELOW I1� ------------------ i j I 11 j RAILING 11 0 1 w DECK 1 " 1 � PORCH FLOOR I I ELEVATION TO I I I O I 31'-0" i MATCH i a I jj 1 ALIGN 1 NEW C.O. ;Q Z f I �Vv + STEP DOWN TO NEW DKK r REFERENCE CERTIFIED PLOT PLAN DATED 2/05/2007 I 3 EXISTING PATIO g KITCHEN 4 I STUDY S DOOR TO REMAIN (EXISTING) 1 iI LIVING ROOM (ANG) DINING ROOM 1 (DasrlrX;) 1 I I I I 151FLR4 ; I i I I FIRST FLOOR PLAN 1 � IFIaSn� 11 STAIRS TO FINISH GRADE I I ZONING SETBACK BUILDER/OWNER CONFIRM I STEP DOWN TO NEW DECK i I RAILING PLANS FOR I -� j Sullivan Residence FIXED SIDELIGHTS 47 Boxford Street t ITO MATCH PATIO DOOR iDECK North Andover, MA I I I I SCALE:1/4"= V-0" DATE:2/26/07 I I I I I II I I FULL HEIGHT ' 4 X 4 WOOD POST FIRST FLOOR PLAN � I I � I I PATIO DOOR UNIT I "ANDERSEN" ,FANDERSEN RENCHWOOD, (EXISTING) I I FG 5468 j I I_�RIDGE BEAM j (ABOVE) I DECK TO FOLLOW j I I "OUTLINE" OF BRICK RETAINING WALL II I I PORCH _--_-- BELOW II I I i i RAILING W I LA PORCH FLOOR i DECK j d ELEVATION TO MATCH STUDY d ALIGN j --_-- 11___ i ------------- NEW C.O. �'O� Z �� N STEP DOWN TO NEW DECK I + Ln KITCHEN EXISTING PATIO STUDY o DOOR TO REMAIN (EXISTING) a i 5 I I RIDGE VENT NOTE: BIRDS MOUTH RAFTER CUT VENDOR CONFIRM SIZING OF ALL ENGINEERED LUMBER SECURE RAFTERS USING FRAMING CONNECTORS PLYWD. GUSSET PLATE NAILED &GLUED 2 X 10 AT 16" O.C. 2 - 14" X 14" MICROLAM LVL 5/8" CDX PLYWOOD ROOF SHEATHING 1/2" GWB ON ASPHALT SHINGLES 12 1 X 3 STRAPPING 1 C� R-30 INSULATION RAFTER TO TOP PLATE FRAMING CONNECTOR. 1" MIN. AIR SPACE ABOVE INSUL. CONTINUOUS DOUBLE TOP PLATE _ TYPICAL EAVES DETAIL: FASCIA & SOFFIT TO MATCH EXISTING CONTINUOUS SOFFIT VENT DOUBLE TOP PLATE HEADER: 2 - 14" X 74" MICROLAM LVL METAL DRIP EDGE = 3/4" T&G PLYWOOD. ENTIRE PERIMETER ICE/WATER SHIELD j NAIL & GLUE TO FRAMING z TYPICAL EXTERIOR WALL. R-38 INSULATION "ANDERSEN" G45 GLIDING WINDOW SIDING TO MATCH EXISTING iD BRIDGING AT I OR SIMILAR "EQUAL" BUILDING WRAP ^ CENTER SPAN 1/2" CDX PLYWOOD SHEATHING JOIST HANGERS (TYP. AT ALL "IN-LINE" FRAMING) 2X4AT16" O.C. R-13 FIBERGLAS INSULATION POLY VAPOR BARRIER 2 - 13/4" X 117/8" MICROLAM LVL 1/2" GWB 2 X 12 AT 16' O.C. ENTIRE PERIMETER 1/2" EXERIOR GRADE PLYWOOD TREATED LATTICE WORK TREATED WOOD FRAMING' r - i =GRADE EXISTING BRICK WALL _j GRAVEL GRAVEL BASE LANDSCAPE MASONRY RETAINING WALL FI PLANS FOR ---- Sullivan Residence 24"DIA. POURED CONCRETE PIER. GALVANIZED POST ANCHOR MIN.4'FROST COVER 47 Boxford Street 4 X 4 TREATED WOOD POST North Andover, MA SCALE-1/4-=1'-0" DATE:2/26/07 PLANS FOR Sullivan Residence TREATED LUMBER AT 47 Boxford Street ALL EXPOSED DECK FRAMING 3 - 2 X 10 North Andover, MA GALVANIZED JOIST HANGERS (TYPICAL) SCALE:1/4"= 1'0" DATE:2/26/07 T72 - 13/4" X 117/8" MICROLAM LVL 2 X 6 (TRTD)( AT 16" o.c. CANTELEVER END BEAM FRAMING FLOOR FRAMING PLAN CONNECTOR DOUBLE 13/4"X 117/8" p MICROLAM LVL 2 - 2 X 10 (TRTD) N N DOUBLE 13/4" X 117/8" MICROLAM LVL X 8 (TRTD)AT 16" O.C. CONTINUOUS TREATED 2 X 10 LEDGER LAG BOLT TO EXISTING FRAMING NEW DBL MICROLAM LVL FLASH TO ALLOW PROPER DRAINAGE 2 - 13/4"X 117/8" MICROLAM LVL PERIMETER BEAM TO REST ON EXISTING STRUCTURE PLANS FOR Sullivan Residence 47 Boxford Street North Andover, MA SCALE:1/4"= V-0" DATE:2/26/07 GUTTER ABOVE DECK AREA ROOF DRAINAGE "CRICKET" RIDGE VENT ® ® RIDGE BEAM MATCH EXISTING RAKE TRIM ri GUTTER y'y MICROLAM BEAM: ii 2 - 14nX7111 ----------- ------------- r EXISTING PATIO DOOR / -------------------------4 ALTERNATE ADD: FINIS 2ND TRANSOM WINDOW IEB ;.i OUTLINE OF ROOF BEYOND LuRAILING 4 X 4 WOOD POSTS PROVIDE RAILING AT DECK (NOT SHOWN) FINISN IST FLOOR--_ FINISH FLOOR PORCH EXISTING BASEMENT DOOR + ------------------- a 1 1 STAIRS TO FINISH GRADE LATTICE WORK DECORATIVE MASONRY RETAINING WALL FINIS BASEMENT FLOOR FINISH GRADE URNISH GRADE i POURED CONCRETE I I I i PIER STYLE FOUNDATIONS REAR ELEVATION EXISTING BRICK WALL - - ' `------ z PROPOSED EXISTING o z O i RIDGE VENT 6 Lnw w w Ln ROOF CRICKET - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - — — — — — - - ASPHALT SHINGLES =_ _ _ _ _ _ _ _ _ _ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - FINISH 2ND FLOOR - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - + ------------------- - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - WOOD CORNER TRIM - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - _�i i. SLIDING WINDOWS 'ANDERSEN' G45 OR SIMILAR CEDAR SHINGLE SIDING LLI -L LLS v{ !? -- Ig FINISH IST FLOOR (STUDY/PORCH) .. E WORK 4 X 4 WOOD POST FINISH GRADE IE I I I I I I i i FINISH BASEMENT FLOOR + ------------------- + 'F PLANS FOR Sullivan Residence FINISH GRADE UNDER PORCH 47 Boxford Street 12"DIA. POURED CONCRETE PIER. POURED CONCRETE North Andover, MA GALVANIZED POST ANCHOR PIER STYLE FOUNDATIONS MIN.4'FROST COVER SCALe:i/4"=1'0" DATE:2/26/07 4 X 4 TREATED WOOD POST LEFT E L EVATI O N GUTTER ABOVE DECK AREA ASPHALT SHINGLES RIDGE VENT GUTTER PLANS FOR _ _ _ _ _ _ _ _ _ _ _ _ _ Sullivan Residence ______=__- V 1'U i Cx9 �� - �53 � � � . �• r ----------- ---------- I I I I NEW CONCRETE PIERS OUTLINE OF NEW j FOR DECK ABOVE jT DECK(ABOVE) I I I I I I e EXISTING BRICK MASONRY RETAINING WALL PLANS FOR I TT Sullivan Residence NEW 24" DIAMETER 47 Boxford Street POURED CONCRETE North Andover, MA PIER FOUNDATIONS DATE:2/26/07 V.I.F. LOCATIONS OF PIERS XX AT ADJACENT TO EXISTING BRICK RETAINING WALL. 4GN I CONCRETE PIER I WITH 4 X 4 WOOD POST I SUPPORTS ABOVE ' I I X. I BASEMENT PLAN -'\"-OUTLINE OF NEW ADDITION(ABOVE) I i I I I I I I I I I I I EXISTING CONCRETE BLOCK FOUNDATION I I I I j OUTLINE OF EXISTING STUDY I I I r ----------- ---------- I I I I NEW CONCRETE PIERS OUTLINE OF NEW j FOR DECK ABOVE j DECK (ABOVE) I I I I I I I EXISTING BRICK MASONRY RETAINING WALL PLANS FOR 1 ' Sullivan Residence NEW 24" DIAMETER 47 Boxford Street POURED CONCRETE North Andover, MA PIER FOUNDATIONS SCALE:1/4"= V-0" DATE:2/26/07 V.I.F. LOCATIONS OF PIERS AT ADJACENT TO EXISTING BRICK RETAINING WALL. ALIGN CONCRETE PIER I WITH 4 X 4 WOOD POST SUPPORTS ABOVE ' BASEMENT PLAN OUTLINE OF NEW ADDITION (ABOVE) I I I I I I I 1 I I I I I EXISTING CONCRETE BLOCK FOUNDATION i I I I j OUTLINE OF EXISTING STUDY I I L--------- --------- I I I 1 ! ZONING SETBACK I� R/OW NER CONFIRM i ! CONFIRM I 1 I STAIRS TO FINISH GRADE I I STEP DOWN TO NEW DECK j I RAILING I 1 1 l FIXED SIDELIGHTS —1 wR - DECK i TO MATCH PATIO DOOR Sullivan Residence I 47 Boxford Street North Andover, MA II 126/07 FULL HEIGHT I;; 1 4 X 4 WOOD POST I I 1 PATIO DOOR UNIT I I I I "ANDERSEN-FRENCHWOOD' I i ii I FG 5468 EXISTING I BRICK f I I`RIDGE BEAM ; WALL? 1 I I 1 DECK TO FOLLOW (ABOVE) I "OUTLINE"OF BRICK RETAINING WALL BELOW ELOW l I II I I I RAILING i II 1 O II I w PORCH FLOOR II DECK ELEVATION TO I I ALIGN MATCH STUDY I I 1 d 1 I I 11 I I I I NEW C.O. STEP DOWN TO NEW DECK N j REFERENCE CERTIFIED PLOT + Vl PIAN DATED 2/05/2007 I z g KITCHEN 3 DOSTING PATIO STUDY DOOR TO REMAIN (MSMG) I 1 LIVING ROOM I I (B2asNrvD) I DINING ROOM I( I (EMSn" I i I i 1STFLR4 I II FIRST FLOOR PLAN ( li STAIRS TO FINISH GRADE I I ZONING SETBACK BUILDER/OWNER CONFIRM I STEP DOWN TO NEW DECK I I RAILING PLANS FOR j FIXED SIDELIGHTS Sullivan Residence DECK I TO MATCH PATIO DOOR 47 Boxford Street II , ; North Andover, MA I � SCALE:1/4"=V-0" DATE:2/26/07 I I I II I FULL HEIGHT FIRST FLOOR PLAN 4 X 4 WOOD POST--A I I j I PATIO DOOR UNIT I "ANDERSEN" ,FANDERSEN RENCHWOOD, (EXISTING) I i I i FG 5468 II I I_—RIDGE BEAM j I j j (ABOVE) DECK TO FOLLOW j "OUTLINE" OF BRICK RETAINING WALL BELOW PORCH II ------------------- - II I i I I I RAILING I I II I W I � PORCH FLOOR DECK j d ELEVATION TO MATCH STUDY d I II I ALIGN ----------- NEW C.O. 7PA110 Z STEP DOWN TO NEW DECK+z X KITCHEN o EXWSTUDY o DOO (EXISTING) a SMT W LU I N I RIDGE VENT NOTE: "BIRDS MOUTH' RAFTER CUT VENDOR CONFIRM SIZING OF SECURE RAFTERS USING FRAMING CONNECTORS ALL ENGINEERED LUMBER PLYWD. GUSSET PLATE NAILED &GLUED 2 X 10 AT 16" O.C. 2 - 14" X 14" MICROLAM LVL 5/8" CDX PLYWOOD ROOF SHEATHING 1/2" GWB ON ASPHALT SHINGLES 12 1 X 3 STRAPPING 1 C� R-30 INSULATION RAFTER TO TOP PLATE FRAMING CONNECTOR. 1" MIN. AIR SPACE ABOVE INSUL. CONTINUOUS DOUBLE TOP PLATE TYPICAL EAVES DETAIL: FASCIA & SOFFIT TO MATCH EXISTING ' CONTINUOUS SOFFIT VENT - DOUBLE TOP PLATE HEADER: 2 - 14" X 74" MICROLAM LVL METAL DRIP EDGE = 3/4" T&G PLYWOOD. ENTIRE PERIMETER ICE/WATER SHIELD NAIL &GLUE TO FRAMING z TYPICAL EXTERIOR WALL. R-38 INSULATION "ANDERSEN" G45 GLIDING WINDOW SIDING TO MATCH EXISTING 1D BRIDGING AT OR SIMILAR "EQUAL" BUILDING WRAP CENTER SPAN 1/2" CDX PLYWOOD SHEATHING JOIST HANGERS (TYP. AT ALL "IN-LINE" FRAMING) 2X4AT16" O.C. zm=� 11 L � R-13 FIBERGLAS INSULATION POLY VAPOR BARRIER 2 - 13/4" X 117/8" MICROLAM LVL 1/2" GWB 2 X 12 AT 16' O.C. ENTIRE PERIMETER 1/2" EXERIOR GRADE PLYWOOD TREATED LATTICE WORK TREATED WOOD FRAMING' EXISTING BRICK WALL GRAVEL BASE LANDSCAPE MASONRY RETAINING WALL ', FINISH GRADE o d PLANS FOR 24" DIA. POURED CONCRETE PIER. S u I I i va n Residence GALVANIZED POST ANCHOR MIN.4'FROST COVER 47 Boxford Street 4 X 4 TREATED WOOD POST North Andover, MA SCALER/4"=1'-0" DATE:2/26/07 PLANS FOR Sullivan Residence TREATED LUMBER AT 47 Boxford Street ALL EXPOSED DECK FRAMING 3 - 2 X 10 North Andover, MA GALVANIZED JOIST HANGERS (TYPICAL) SCALE:1/4"= 1'0" DATE:2/26/07 2 - 13/4" X 117/8" MICROLAM LVL 2 X 6 (TRTD)( AT 16" o.c. CANTELEVER END BEAM FRAMING CONNECTOR FLOOR FRAMING PLAN DOUBLE 13/4"X 117/8" C3 MICROLAM LVL 2 - 2 X 10 (TRTD) N N DOUBLE 13/4" X 117/8" MICROLAM LVL X 8 (TRTD) AT 16" O.C. I CONTINUOUS TREATED 2 X 10 LEDGER LAG BOLT TO EXISTING FRAMING NEW DBL MICROLAM LVL FLASH TO ALLOW PROPER DRAINAGE 2 - 13/4"X 117/8" MICROLAM LVL PERIMETER BEAM TO REST ON EXISTING STRUCTURE PLANS FOR Sullivan Residence 47 Boxford Street North Andover, MA SCALE:1/4"= 1'-0" DATE:2/26/07 GUTTER ABOVE DECK AREA ROOF DRAINAGE "CRICKET" RIDGE VENT -Z RIDGE BEAM Ed � MATCH EXISTING RAKE TRIM Li-U [DI r� IVi GUTTER g'y MICROLAM BEAM: ii 2 - 14" X 7"" EXISTING PATIO DOOR / ?_______________________�; ALTERNATE ADD: 1 ! ------ TRANSOM WINDOW FINIS 2ND �_\��� I I ------�I ' - ---------- �-_- --�i i------�---- I . ! ! L r77 ' ' OUTLINE OF ROOF BEYOND RAILING ' I I 4 X 4 WOOD POSTS PROVIDE RAILING AT DECK ` (NOT SHOWN) FINISN IST FLOOR — ; ; FINISH FLOOR PORCH EXISTING BASEMENT DOOR + ------------------- a11111 tillil fill NEW STAIRS TO FINISH GRADE LATTICE WORK DECORATIVE MASONRY RETAINING WALL FINIS BASEMENT FLOOR FINISH GRADE f 11 FINISH GRADE I I i I POURED CONCRETE REAR ELEVATION � PIER STYE FOUNDATIONS � I EXISTING BRICK WALL z PROPOSED EXISTING o z O i RIDGE VENT w W LnW ROOF CRICKET - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - ASPHALT SHINGLES - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - FINISH 2ND FLOOR - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - + ------------------- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - WOOD CORNER TRIM - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - �. SLIDING WINDOWS 'ANDERSEN' G45 OR SIMILAR CEDAR SHINGLE SIDING 1=11 =1i. F-F] ffl�Lt FINISH IST FLOOR STUDY/PORCH) " + —-—-—-—-—-—-—-—-—-— E WORK 4 X 4 WOOD POST FINISH GRADE I I I I I i I i FINISH BASEMENT FLOOR + —-—-—-—-—-—-—-—-—-— I I I I I + I I I PLANS FOR i i I I I 1 Sullivan Residence _.J FINISH GRADE UNDER PORCH 47 Boxford Street 12"DIA. POURED CONCRETE PIER. POURED CONCRETE North Andover, MA GALVANIZED POST ANCHOR PIER STYLE FOUNDATIONS MIN.4'FROST COVER SCALE:1/4"=V-0" DATE:2/26/07 4 X 4 TREATED WOOD POST LEFT E L EVATI O N GUTTER ABOVE DECK AREA ASPHALT SHINGLES RIDGE VENT GUTTER PLANS FOR _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Sullivan Residence -=_=______- _______=____- 47 Boxford Street - - - - - - - - - - - - ____________ North Andover, MA _ _ _ _ _ _ _ _ _ _ _ _ _ _ _j - _ _ - - - - _ _ _ _ _ _ SC1LE:1/4"=1'0" DATE:2/26/07 FINISH 2ND FLOOR _________________ _