HomeMy WebLinkAboutMiscellaneous - 5 CHRISTIAN WAY 4/30/2018 5 CHRISTIAN WAY 210/104.D-0143-0000.0 Date.Q�. ...� v/� ........ OF NOwTN,� TOWN OF NORTH ANDOVER n PERMIT FOR WIRING SsgCHUSE This certifies that .( /!1�?n..`T......... P� e--............................................ has permission to perform ���G�'�Z, '1' 1�` �Y` . P..S lb 0 ............ .........................................................................r wiring in the building of...� C�/ . ................................................................................ �.......,North Andover,Mass. Fee..r�. . .....Lic.NoA.d..6. .................................................................................... ELECTRICAL INSPECTOR Check# tnommonweall�i o� aeeac�uea¢tta Official UseOnly 2¢partment 01-7i"S¢rvices Permit No. } 117 Occupancy and Fee Checked BOARD OF FIRE PREVENTION REGULATIONS '[Rev. I/07j leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 2� 17-11 LP City or Town of: N Q r h A rJd 0Vf r To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 5 Chrl Sf1 GYI WQA y Owner or Tenant M Cha e/ bund Telephone No. (o17.'YO• i Z 38 Owner's Address 5 wA� Is this permit in conjunction with a building permit? Yes No ❑ (Check Appropriate Box) Purpose of Building Mount array to roof Utility Authorization No. Existing Service Amps / Volts Overhead❑ Undgrd❑ No.of Meters New Service Amps / Volts Overhead❑ Undgrd❑ No.of Meters Number of Feeders and Ampacity ' Location and Nature of Proposed Electrical Work: Install solar PV array n MVVRA S /e,-w !f Com lesion o the ollotivin table na be waivedby the hu ector of Wires. No.of Recessed Luminaires No.of Cell:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ n- EJ o.o Emergency Lighting rrrd. rnd. Battery Units No.of Receptacle Outlets No.orOil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners o.o eteng D Initiating Devices No.of Ranges No.of Air Cond. Total Tons No.of Alerting Devices HeatTump Number ons o.o e - onta neNo.of Waste Disposers . . ... ' "'""" ' otals: "._".""'"" Detection/Alerting Devices No.of Dishwashers Space/Arca Heating KW Local❑ Municipal ❑ Other Connection No.of Dryers Heating Appliances Key Security ystems: RDatNo.of Devices or Equivalent No.o Water KNo.of a Wiring: Heaters Si ns Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications wing: No.of Devices or Equivalent OTHER: 4j Attach additional detail ifdesired,or as required by the Inspector of lVires. Estimated Value of Electrical Work: 3T f Z� (When required by municipal policy.) Work to Start: 2 2 q Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. Tile undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ❑■ BOND ❑ OTHER ❑ (Specify:) y I cer1 j&,under the penis mid penattles of perjury,that the information on this a ik lon is trite and complete. FIRM NAME: Northeast Electrical LIC.NO.:A16864 Licensee: Clifford George Signature LIC.NO.: (If applicable,enter"exempt"in the license number line) / Bus.Tel.No.:781.272.4899 Address: 1NDMAV4sm1*ti0U*Qt nMA01803 Alt.Tel.No.: 'Per M.G.L.c. 147,s.57-61,security work requires Departme�,617 Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive thti requirement. I am the(check one)❑owner ❑owner's agent. Signer/Agent CQ��roc PERMIT FEE:$ Si nature T��phone No. � r4CO CERTIFICATE OF LIABILITY INSURANCE ,U08�1015 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: it the cerlileate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed.It SUBROGATION IS WANED,subject to the terms and cWitions of the policy.certain policies may require an endorsement.A statement on this certificate does not corder rights to the certificate holder in lieu of RO endorsement st PRODUCER CONTACT FEDERATED MUTUAL INSURANCE COMPANY HAMEs CLIENT CONTACT CENTS HOME OFFICE:P.O.BOX 328 ac No Bet):888.3334949 Al No:5074464M OWATONNA,MN 55060 nM aL TC INS.CO INSURERISI AFFORD NO COV RAOE NAIC 0 INSURER A.FEDERATED MUTUAL INSURANCE COMPANY 13535 INSURED 297.673-6INSURER e: NORTHEAST ELECTRICAL INC,NORTHEAST SOLAR SERVICES INC INSURERC: 1 NORTH AVE BURLINGTON,MA 01803 INSURER D: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:54 REVISION NUMBER:2 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN.THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.OMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. IN7R Typg OF INSURANCE DL UBR PC0.1Cy NUMBER OIICY EfF POLICY EM% LIMITS LTR S IH110 DOIYY MNID^, 0 ERAL LIABILITY EACH OCCURRENCE $1.00D.ODO DAMAGE IT?RENTED $100,000 X COMMERCIAL OENERAL LIABILITY �pREM19EJ IEe aalrwlc+T__ _.I CLA3MS•MADE ❑X OCCUR MID EXP(Am un penai) EXCLUDED A Y N 9884084 12/31/2014 12131/2016 PERSONAL A ADV INJURY I $110001000 I I OENERAL AGGREGATE I $21OD0.000 X�L AGGREGATE LIMIT AP^PLIES PER: I PRODUCTS•COMPIOP A00 I $2.x.000 pOl1CY JiC7 1 1 LOC AUTOMOBILgLLABILITY 1E.M.911YINGLE LIMIT $1.000.000 X ANYAUTO 00DILYINJURY(Per pereor.) ALLOA ANTOSMEO AUTOS U�D Y N 9884085 12/31/2014 12/31/2016 BODILY INJURY(Per stefftO --J HIREO AUTOS MON-OWNED eRO11g Y RAMAOE X UMBRELLA LIAS X OCCUR EACH OCCURRENCE $5,000,000 A EXCESS LIAR CLAIMS-MADE N N 9884OS7 12/31/2014 12131/2018 AGGREOATE $5,000.000 DEO RETENTION TT WORKERS COMPENSATY X TORT1T8 IF AND EMPLOYERS'LIABILITY ANY PROPRIETORJPARTNEMIXECUTIVE K.L.EACH ACCIDENTN 1 a IJN 9884086 12/31/2014 12/31/2016 rI 51,000,000 A man"IMEMBER E%ClUDEOi .L.DISEASE•EA EMPLOYEE 1 =1,000,1100 Mandatory in NH) If Tee.de/oribsulder [A DISEASE•POLICY LIMY DESCR,TIOH OF OPERAIKINS below 5110001000 DESCRIPTION OF OPERATIONS/LOCATIONS 1 VEHICLES(At"ACORD 101,AddSanal Remits Sft ulo.It mus space Is required) THE CERTIFICATE HOLDER IS AN ADDITIONAL INSURED SUBJECT TO THE CONDITIONS OF THE ADDITIONAL INSURED BY CONTRACT ENDORSEMENT FOR GENERAL LIABILITY. THE CERTIFICATE HOLDER IS AN ADDITIONAL INSURED SUBJECT TO THE CONDITIONS OF THE ADDITIONAL INSURED BY CONTRACT ENDORSEMENT FOR BUSINESS AUTO LIABILITY. CERTIFICATE HOLDER CANCELLATION 542 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE 4�4 4)1988.2010 ACORD CORPORATION.All rights reserved. ACORD 26(2010105) The ACORD name and logo are registered marks of ACORD The Coiiiniottivealth of Massachusetts Department of Industrial Accidents Office of hivestigations I Congress Street, Snite 100 Bostoti, MA 02114-2017 Iwvly.tttass.gov/din Worlters' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Le ibl Name(Business/Organization/Individuap: Northeast Solar Services Inc Address: 1 North Ave Suite A City/State/Zip:Burlington/MA/01803 Phone#:781 -270-6555 Are you an employer?Check the appropriate box: Type of project(required): 1.O 1 am a employer with 12 4. ❑ I ani a general contractor and 1 6 ❑New construction employees(fill and/or part-time).* have hired the sub-contractors listed on the attached sheet. 7. ❑Remodeling 2.❑ 1 ani a sole proprietor or partner- ship and have no employees These sub-contractors Have g, [j Demolition working for in any capacity. employees and have workers' 9. E] Building addition [No workers' comp. insurance comp.insurance.= . ❑ 5We are a corporation and its 10.❑Electrical repairs or additions required.] 3.C1 I atn a homeowner doing all work officers have exercised their 11.❑Plumbing repairs or additions right of exemption per MGL myself.[No workers comp. 12.[:]Roof repairs employees.[No workers' insurance required.]t c. 152, 1(4),and we have no 13.❑✓ OtherSolar PV comp. insurance required.] *Any applicant that checks box p 1 must also rill out the section below showing their workers'compensation policy inrormation. t Homeo%miers who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. lContraetors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. if the sub-contractors have employees,they must provide their workers'comp.policy number. 1 ant aft employer that is providing tvorkers'compensallon histu'ance for my employees. Below is the policy and job site information. Insurance Company Name:Federated Mutual Insurance Company Expiration Date, 12/31/2016 9884086 Ex Policy#or Self-ins.Lic.M. P Job Site Address: 7 C,4f—%✓Tl A N WAY _City/State/Zip: !.!> Am D v A �0(-&q5 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration(ate). Failure to secure coverage as required tinder Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. �Sina hereb cern trader the ai is andpenalties o er'ti that the in orntntion provided above is trite and correct. ture: - - Date: �- i® i tv Phone#:781-270-1899 Officlol rise only. Do not write in this area,to be completed by city or town official. City or Town: Permit/Liceuse# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector G.Other Contact P erson: Phone#: " _ to �a .�-s'1Oi.[�L�'.�1�01N1111;��i ;S PROJECT DESCRIPTION Contractor: THIS ROOF MOUNTED PHOTOVOLTAIC (PV) SYSTEM 15 TO BE INSTALLED AT THE SINGLE-FAMILY DWELLING IN NORTH ANDOVER, MA55ACHU5ETT5. REVOLU(SSUIN THE ENERGY PRODUCED BY THE PV SYSTEM SHALL DE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ON-SITE ELECTRICAL EQUIPMENT VIA �—°°'°` A SUPPLY 51DE CONNECTION IN THE MAIN SERVICE PANEL. THIS PROJECT DOES NOT INCLUDE STORAGE BATTERIES. I NORTH AVENUE BURLINGTON,MA 01803 SHEET INDEX SCOPE OF WORK CONSTRUCTION NOTES P:(781)270-6555 TI.0 COVER (33) PV MODULES(TOTAL: 580 SQ. FT.) 1.)CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO www.Ma55xhu5ctt5.Revolu5un.com Al.0 51TE PLAN (1) 1 O.O kW INVERTER INITIATING CONSTRUCTION. 2.)CONTRACTOR SHALL REVIEW ALL MANUFACTURER INSTALLATION A I.I ROOF: PV LAYOUTS (33)50LAREDGE POWER OPTIMIZERS DOCUMENTS PRIOR TO INITIATING CONSTRUCTION. A2.0 MOUNTING$RACKING METHOD (74)ATTACHMENT POINTS @ 48"O.C. MAX. 3.)ALL EQUIPMENT SHALL BE LISTED BY U.L.(OR EQUAL)AND L15TED FOR E 1.0 ELECTRICAL DIAGRAM (1)AC DISCONNECT, 240 VAC, NEMA 3R ITS SPECIFIC APPLICATION. 4.)ALL EQUIPMENT SHALL BE RATED FOR THE ENVIRONMENT IN WHICH IT Protect: E2.0 SAFETY PLACARDS (1) LOAD CENTER, 240 VAC, NEMA 3R I5 INSTALLED. DUNN RESIDENCE DI.0 PV MODULE DATA SHEET (1)PV METER, 240 VAC, NEMA 3K 5.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE 5 CHRISTIAN WAY 1545 MANUFACTURERS INSTALLATION INSTRUCTIONS. NORTH ANDOVER,MA 0 D2.0 PV INVERTER DATA SHEET JOB#:MA02_16-002-4 4 6.)ACCESS TO ELECTRICAL COMPONENTS OVER 150 VOLTS TO GROUND D3.0 50LAREDGE OFTIMZER DATA SHEET SHALL BE RESTRICTED TO QUALIFIED PERSONNEL. Protect Details: 7.)ALL CONDUCTORS SHALL BE COPPER,RATED FOR GOO VOLTS AND 10.791 kW5tc, 10.00 kW AC SITE SPECIFICATIONS 90°C WET ENVIRONMENT,UNLESS OTHERWISE NOTED. PARTS LIST OCCUPANCY CATEGORY: II 8.)WHERE SIZES OF JUNCTION BOXES,RACEWAYS,AND CONDUITS ARE NOT SPECIFIED,CONTRACTOR SHALL SIZE THEM ACCORDING TO Engnneermg Approval: Quantity De5crlption DESIGN WIND SPEED: 100 MPH APPLICABLE CODES. EXPOSURE CATEGORY: B 9.)PV MODULE FRAMES SHALL BE BONDED TO RACKING RAIL OR BARE 33 SolarEdge P400 GROUND SNOW LOAD: 50 P51' COPPER G.E.C.PER THE MODULE MANUFACTURER'S LISTED INSTRUCTION SHEET, 45 PV Module 10.)PV MODULE RACKING RAIL SHALL BE BONDED TO BARE COPPER 74 QMPV Classic Comp Flashing G.E.C.VIA WEEB LUG,IL5CO GBL-4DBT LAY-IN LUG,OR EQUIVLENT LISTEDLUG. 74 Unirac L-Foot GOVERNING CODES 1 1.)GROUNDING ELECTRODE CONDUCTOR(G.E.C.)SHALL BE CONTINUOUS 2014 NATIONAL ELECTRICAL CODE AND/OR IRREVERSIBLY 5PLICED/WELDED. 74 5/1 G"Lag Screw 780 CMR, 8th EDITION 12.)ALL JUNCTION BOXES,COMBINER BOXES,AND DISCONNECTS SHALL BE INSTALLED IN AN ACCESSIBLE LOCATION. 246 Feet of Unirac 5unFrame Rail UNDERWRITERS LABORATORIES(UL)STANDARDS 13.)ROOF ACCESS POINTS SHALL BE AT A STRONG POINT ON THE 05HA 29 CFR 1910.269 BUILDING AND NOT REQUIRE THE PLACEMENT OF LADDERS OVER EXTERIOR REVISIONS WALL OPENINGS. DESCRIPTION DATE REV 14.)WORKING SPACE AROUND ELECTRIAL EQUPMENT SHALL COMPLY WITH ORIGINAL 1121/2016 A NEC 110.26 EQUIP RELOCATE 1/2G/201G B why+ AA EQUIP RELOCATE II 1/27/201 G C ...n....... ' e � ' • J .I� 1e` , ,` i OY� nJ `f~µmw LL� .�S• Sheet Title: COVER heet Numer: b X l TI .O Sheet 5ae: AN51 B - 17"x I I� 1 l! . r ""' :� ✓ mese 6AR� DESIGN t DRAFTING 5y: •r•` w -; •P - '•; ♦ JOEL HORST C f. c',�axe SEPISO PARCEL MAP �� " AERIAL MAP ��I w�Y VICINITf MAP �l Renewed 4 Approved by: PROJECT LOCATION EH Contractor: 200'TO CHRISTIAN WAY REVOLU(SUN r I NORTH AVENUE BURLINGTON,MAO 1603 P:(781)270-6555 215° www.Mn5xhuxtt5.RcvoY)sun.com ProJcct: DUNN RESIDENCE 5 CHRI5TIAN WAY NORTH ANDOVER,MAO 1845 JOB N:MA02 1 G-0024 70'-9" Project Details: 10.791 kWstc, 10.00 kW AC 3/4"EMT THROUGH ATTIC UTILITY METER f DOWN CHASE TO BASEMENT Engmeenng App oval: MAIN SERVICE PANEL AC DISCONNECT I PV METER I INVERTER W/DC DISCONNECT PV LOAD CENTER e REV151ON5 DE5CRIPTION DATE REV ORIGINAL I/21/2016 A DRIVEWAY --- — 48'-4" 4QU1PRELOCATEI 1/26/2016 e V ARRAY EQUIP RELOCATE II 1/27/2016 C OPTIMIZERS UNDER PV MODULES JUNCTION BOX 3G°PITCH TYP. Sheet Titic: SITE PLAN Sheet Number: A I .O sheet sae: ANSI B- 17"x I I" DESIGN E DRAFTING BY: /)/ JOEL HORST f—6 ft 12 ft— 24 ft Reviewed 4 Approved by: SCALE: I"= 12' EH 15'-3" Contractor: RIDGE 4MAX. f--+1'-4"TYP. I I I I I I I I I I 1 REVOLU(SUN ft II T II II r II II ft' 11 II rIt �a ar.�a�.so1ar. I NORTH AVENUE I I I I I I I I 1 I 1 BURLINGTON,MA 01803 I II II it II II 7 ?1 II II II II II I I P:(781)270-6555 �� II 11 II II II II II II II 11 11 II 1 II www.Ma5wdwsdt5.Raoktun.com II ii i it II II p II II II II II II II II I II I II II fl II II II II II II II II II II II ilt, ji I r-IT II II ull 111 II FIr, II II FIT II II i i II IT 11 II II I II II II II II � i II II II II II I II 11 II Project: II IIif 11 It 11 11 11 11 11 �I II 11 17 G" DUNN RESIDENCE 5 CFl R15TIAN WAY II II II I II II II II II (I 11 II II 11 II II i 11 II II 11 NORTr1 ANDOVER,MA 01845 11 JOB N:MA02 I G-0024 II II II II I II II II II II 11 II II 11 II II 11 I II II 11 11 II - 1I it II II 11 II p II II p II it II p II II 11 1 11 II 11 11 _� II r i it I 1 I Project Detad5: I091kW5 'W't'. 10.00 kW AC II �I I II II 11 11 I II II II II II 30'-I�„ II II it II II 1 1i II II II I II II Engineering Approval: II 1 I I I I I I4 i I i I it it II I II ii II �I I II II II II II II II II II it II II i II II II II I I II �� 1 I II 11 II I i II II II II II 36°�PITCII11 11 II II it p II i II II II 11 I II it 11 MAIN ROOF jl II SAVE II II lI 1 II I L II II 1 L II II 1 II II 11 1 Il II Il L II II I II II I1 II '_I �I jl jl II SCALE: I"=4' — — — — — - — — — it 441-411 _1 --2 It 4 ft 8 ft -- LEGEND � FLA5HING RAPTER/TRU55 PV MODULE 23'-5" � I REVISIONS I'-4"TYP. L I I DESCYJY ION DATE REV r—T4'MAX. L ORIGINAL 1/2vzo1G A —, i—, i , —, RIDGE I I 215° I I I I I J EQUIP RELOCATE 1 1/2G/201 G B EQUIP RELOCATE 11 1/2]/2016 C Tl 1 II I II II II 1 II 11 II II II II II 11 II I I I I 1151-411. I I I I I II II II II II 11 Q II II II II 4 II I II II 11 II II 11 II it II IT1 II I Ti II II F IT II I - Ti II - Ti II II II II II II II II II II II II Sheet Title: II II II II II II II I 11 U II II II II II II II ROOF it 11 p II II II II I 11 II II II II II II II it PV LAYOUTS IL, Il, II II IL, II 11 , 11 11 IL, II ii 11 II Ii II 1 1 1 1 1 1 1 II 1I 1 II Il 1 9 1 11 11 j1 11 11 11 14•_61, Sheet Number: 71 -7 11 II -IT II 11 1 II II IT 11 11 II 11 II 11 A I . I ii II II II II II it I II II II 11 it II it II it 5heet 51ze: II II II II II II II I II II II 11 II II II II II ANSI B - 17"x I I" rte II 11 II II ifs I II rl� rrF II II II 11 11 II _ 11 11 i1 II it II ESIGN t DRAFTING BY: II 11 II 11 II 11 II I II 11 Q II II it II it 11 JOEL HORST II II II II II U II I II II 11 II II 3G" 11 11 11 �.:C co ,C1p 11 II II II I I II II I II II 1I II II II II 11 II ,. . :.,art c� T 1 11 1 T 11 I I 1 T'i I I 11 T l U T 11 11 11 II I I I I ;t,;3<<�cx�u I-- - OL AR GARAGE ROOF ��f 2 ft—{-�--4 ft�—8 ft EAVE Reviewed 6 Approved by: SCALE: I"=4' Et1 I I 1 1 I I I I I I I I I I 1 1 Contractor: II 11 II 11 11 11 1j II � I I I I I I I I I I I I I I I I REVOLU(SUN RAFTER •I I 1,_4.TYP III I I I I I I I I I I ( I 1 NORTH AVENUE i V I 1 1 1 1 1 1 I I I I I I I I BURLINGTON.MA 01803 PV MODULE I I I Ito1 1 1 1 1 1 P:(781)270-6555 —— - www.Mj5uchusetts.Revok)%m.com II--� I 16'MAX.1 1 I I 'MAX I I I i t i t i I 1 I I I I I I 1j II II II II II II I 1 1 1 1 1 1 I I 1 1 1 1 1 1 I Project: 1 1 1 1 1 1 1 1 1 1 1 1 I DUNN RESIDENCE I I I I I I I I I I 1 1 I I I 5 cF1R15TIAN WAY NORTd ANDOVER,MAO 1845 1 1 I I 1 1 I I 1 1 I I I I I JOB#:MA02_I G-0024 I I I I I I I I I I I I I I Project Deta115: I I 1 1 1 1 I I I I I I I I I 10.791 kW5tc, 0.00 kW AC 1j II II II II II II I II II II II II II II I STRUCTURAL CALCULATIONS 1 1 I I I I I I I I 1 1 I I I En,3—ring Approval: QTY WEIGHT EA. TOTAL I I I I I ( I I I I I I I I I II II 11 11 II II II I PV MODULE 33 x 41.O LBS = 1353 LBS FLASHIN 1 1 I I I I I I I I 1 1 1 1 I RACKING RAIL 24G x 0.75 LB/FT = 185 LBS L FOOT ATTACHMENT 74 x 4.0 1-155 = 29G 1-135 RACKING RAIL I I I I I I I I I I I I I I I TOTAL WEIGHT: 1834 LBS PACKING I 1 1 I I I I I I I I I I I ARRAY AREA: 579 SQ. FT. DEAD LOAD: 3.2 P5F POINT LOAD: 24.8 LBS I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 1 REV1510N5 8 In-f Gin- 32 in �� OR GDt5CN/.L ION 1/21/2016 PAV MOUNTING PLAN VIEW 5CALE: I"= IG* EQUIP RELOCATE (/26/2016 5 EQUIP RELOCATE II 1/27/2016 C 3 \ UNIRAC CAP STRIP G PV MODULI UNIRAC 5UNFRAME RAIL Sheet Tltle: NIRAC LFOOT MOUNTING \ CAS51C UN MOUNT RACKING METHOD i CLLASSIC COMr MOT - !� _ heet Number: �ooF A2.0 COMrOSPION AWIMNUM rL.-%Nw- hee[512e: 1 7"x I I" _ X5/1 G'55 LAG SCREWE51GN E DRAFTING BY:--------- I ' S N 2.1/.-ED WYCHEM Nm (I_Alio IJIV.) JOEL hOR5T MOUNTING METHOD MOUNTING DETAIL SCALE: I"= 1 2" 2 3 _ —�—' SCALE: I"=6" SEPISOLAR �- Gin t 2 1n 24,n Gin 12 m p�Newed C Approved by: / EH --EQUIP.GROUNDING CONDUCTOR I--CIRCUIT CONDUCTOR -CIRCUIT BREAKER (N)-NEW EQUIP. (E)-Ex15TING EQUIP. L -LINE I(BLACK) L2 -LINE 2(RPD) -NEUTRAL BVHITE) ©-GROUND(GREEN) -POSITIVE(RED) -NEGATIVE(BLACK, Contractor: Array Configuration PVMod uleSpecifications InverterS ecifications Power Optimize r5pecifications AC System Summary System:10.791 kWstc,10 kW AC Model Number: SUNPOWERE20-327 Model Number:Solar EdgeSE100DOA-US Model Number: SolarEd eP400 NOMINAL SYSTEM VOLTAGE: 240 Volts AC REVOLU. SUS Total PV Module :33 Weight: 41.0 lbs Power Rating: 10.00 kW AC Max Input Power: 400 Watts MAX CURRENT PER 690.8(A): 42 Amps Inverterl.D.# Inv#1 Dimensions: 61.39 x 41.18 X 1.81 (in) Nominal Voltage: 240 Volts AC Max Voc: 80 Volts DC MAX CURRENT PER690.8(B): BUR 53 Amps I NORTtfAVENUE s DC LINGTONP:(781)2700--6$55555 03 Inverter AC Power(kw): 10.00 Module Power @ STC: 327 Watts Max Output Current: 42.0 Amps Max Isc: 10.1 Amp , PVPower(kWstc): 10.79 Voc(open-circuit Voltage): 65 Volts DC CEC Weighted Efficiency:97.55S Output Current: 15 Amps www.MusuGhuxttS.Revalusun.com Module Total qty: 33Vmp(max-power Voltage): 54.7 Volts DC Maximum DC Voltage: 500 Output Voltage: 60 Volts DC Inverter DCAC Ratio 1.08 Isc(short-circuit current): 6.5 Amps I Inverter Quantity: 1 Min.String Length: 8 String W. 2 Imp(max-power current): 5.98 Amps Max.String Length: 25 Q String Length: 12 Mfr Voc Temp Coefficient: -0.27 %/°C Max.String Power: 5,250 Watts j Max Open Circuit Voltage 500 Protect: DUNN RESIDENCE 0• Operating Voltage: 350 5 CHRISTIAN WAY Z NORTH ANDOVER,MAO 1845 Max Short Circuit Current 28.0 JOB#:MA02 IG-0024 Operating Current: 22.4 [,-J,ct Details: Stri ng Qty: 1 10.791 kWstc, 10.00 kW AC m String Length: 9 H Max Open Circuit Voltage 500 O. Operating Voltage: 350 TO UTIUTY GRID EH,3,.-rmg Approval: Z - Max Short Circuit Current 10.5 Operating Current, 8.4 (DLw exRRloR.wAu.- O (DILIY METER Nu Ip)AC D15CONNECT -PHASE.240 V Ix.ReR I (N)PV LOAD CENTER `N)PV METER 12'ovyR u-O �LUTeo -- -1-IFTID 111 N ROOriOPBAS I IN CMCNT-� OCUS EGATC I O 19�oNxe POINT OP INTERCONNECTION 240 VAC,2W A tto ) (N)LINP 5101 TAY mo0ult I IN)INVERTER(QTY 1) ) 55n PER NEC 240.2I(b)(I)4705.12(A) aA O Y LENGTH OF TAP CONDUCTORS (N)COMBINEK BOA I u7 n V SHALL LOT PxCEEO 101T Rxx crq,NCI ft Tw - - -1200 A (E)MABN SERVICE OIXONNECT s5 A L - I 2DD A.240 V,2-P REVISIONS 0O1�gX4 A1xWR I oBUS BARS:200A DE5CP.IPTION DATE REV I ORIGINAL 1121/2016 A 1 2 12 1 2 12 1- 2 -- 9 1- •' . - I EQUIP RELOCATE 1/26/2016 B 1 I ' (E)MAIN SERVICE PANEL EQUIP RELOCATE II 1/27/201 G C 5TKING 1:(1)PV MODULE PER OPTIMIZER 5TRING 2:(1)PV MODULE PER OPTIMIZER STRING 3:(1)PV MODULE PER OPTIMIZER L- --- 12)OPTIMIZER5 CONNECTED IN 52NE5 (12)OPTIMIZERS CONNECTED IN 5ERI[5 (9)OPTIMI IER5 CONNECTED IN SERIES 3.924 kw' TOTAL 3.924 kWAtc TOTAL 2.943 1W TOTAL --0N ROOFTOPI IN BASEMENT- I(E)GROUNDING ELECTRODE SYSTEM I � heet Tele: WIRE AND CONDUIT 5CHEDULE ELECTRICAL COND COND COND GND GND GND CONDUIT CONDUIT EST. DIAGRAM PV System Maximum Voltage Calculation per NEC 690.7(A) TAC' QTY 51ZE TYPE QTY 512E TYPE 512E TYPE D15T. heel Number: Local Record Low Temp: -18`C Data Source: LAWRENCE MUNI F I .O 25'C- Voc Voc Number of Termperature DCI 2/5TRING AWG# O PV-WIRE I AWG#G BARE CU WA WA JO L Voc Temp DC2 2 AWG#8 THWN-2 Sheet Slze: Coefficient x Record +1 = Correction Correction x Voc x Modules in = Corrected Open AWG#1 0 THWN-2 3/4" EMT 50 Low Temp. Factor Factor Series Ci rcuit Voltage DC3 2 AWG#10 THWN-2 ANSI B - 1711 X I I D 0.27%/°C x 43°C +1 = 1.116 1.116 x 64.9 x 1 = 72.4 Volts DC AC 1 3 AWG#G THWN-2 I AWG#8 THWN-2 3/4" EMT 50DESIGN 4 DRAFTING 1: / CONDUCTORSPECIFICATIONS REQUIREDCONDUCTORAMPACITT AMPACITY CHECK Ml61N CONDUCTOR TEMPERATURE DERATNG CONDUITFILLDEMTNG CORRECTED AMPAOW CALCULATON AMPACIWCHECK82 VOLTAGEDROP JOEL HORST TAG CIR[Urt CIRCUIT Avrr! TING PCO, ORIGIN DESTINATION TERI TSME = PER - DX . M ro 1 DCI PVET G COMBINER 90z COPPER R90'[ AWG N3031Og0 Amb SSR(pr ,TARIIxcs - 1 5.0 An RL25a lB.e Camps 18.80Am <400A/smps TEM3�GN ooFl n p.ss2z 0 TE 54 mR076zox CONN/AOR m'10030x AM 40 1 0.]6Ex 01.001= 30.4 Tr 6BORampz<WA amps O110 xm 011% DO COMBINERER) NV,- COPPER JS'C AWGNB 50 Ams 15.00 x s 2 = 30.0 amps x 1.25 = 3].5 amps 37.5 amps <50.0 A,qs [NR 32 31 N/A s 32 ] 0.94 4 s Bs 0.80 a 50 x 0.94 x ELM 37.6 s 30.0 Ams<37.6 Amz 501, 0.71% ^']•` ����� DC3 COMMNER00% INVERTER COPPER 75•C AWGNIO 35 Ams 15.00 x 1 • 15.0 Anps x 1.25 = IRR Amps 18.8 Ams <35.0 Ams 32 - N/A 32 094 4 Dw 35 x 0.94 x 0.80 = 26.4 15.0 s<26.4 Amps sort 0.5]% SOLA CONDUCTORSPECIFICATONS REQUIRED CONWCTORAMPACITY AMPACIVC1ECI CONDUCTORTEMPEMIURE pERATNG CONDUR FILL DEMTNG CORRECTEDAMPACIIYCALCUTATON AM-m`CHECKN2 VOLTAGE DROP ' CIRCUIT OrAE z%0 oERAT6o TAG [IRNRDESnNATION r6R MAx ]ssx PER MAx Msx rlxG ANwaOtt n0u NR ORIGIN MATERIN TE ® DurPur x =WRRENT PER x =a6RErvr PER cuRRExr PER arAN ORDIIT ENVIRONMENT D ca6R6rn mFlu - <CONDUCTOR Reviewed 6 Approved by: Sae DER 601.BIN(]Ilal att 'N Mel'Q I REx NR. TRADE NOF Du L P AxvAOtt o r[nw mrv0u PER rvew V.- 4 F mxPAO OR RAnNG srzE IrvvERTERs N4PA AZ ICN r[ m8R6rnory urvN.Lo ory " ERAr ERAT RMPA z a AMP att IsraN DROP AM ry D E x Hort 3]4]B]6 NRRExT 650.0.a 3 690.0 7 a 690.0 3 a TEMP 10.]0 3 a CONDUROR9 3]0.]5 B a a D E ory 690.B A D O Eh Afl INVERTER SPUCE WITN IXISTNG CONDUCTORS COPPER ]5'C AWG N6 65 Ams 420 x 1 = 42.0 s x 1.25 =.52.5 Pmps 52.5 Arps< 65 1 Ix0DOR5(w•O 32 32 0.94 3 1.00 65 x 0.94 x 1.00 = 61.1 s 42.0 Amps 1 63.1 Amps 50 ss 0.86% Contractor: WARNING WARNING ELECTRIC SHOCK HAZARD ELECTRIGSHUCK HAZARD REVOLU(SUN IF A GROUND FAULT IS WIOATEDDO NOT TOUCH TERMINALS NORMALLY GROUNDEDCONDIICTORS TERMINALS ON BOTH THE LITE Y�ENERC�[IM AND LOAD SIDES MAY BEEUMM I NORTH AVENUE BURLINGTON,MA 01803 P:(781)270-6555 REQ'D BY:NEC G90.5(C) REQ'D BY:NEC GOO.1 3(B) �� REQ'D BY:NEC G90.13(13) �� REO'D 4 BY:NEC 690.1 7(E) REID'D BY:NEC 690_3 I(G)(3) 5 APPLY TO: APPLY TO: APPLY TO: APPLY TO: APPLY TO: www.ma5uchusdt5.Rcvob5un.com INVERTER(5).IF NOT APPLIED BY MFR DC DISCONNECT SWITCHES AC DISCONNECT SWITCHES DISCONNECTS,FUSES,CIRCUIT BREAKERS JUNCTION BOXES,RACEWAYS,CABLE TRAYS, CONDUIT BODIES WITH AVAILABLE OPENINGS. EVERY 10',WITHIN I'OF TURN5/PENETRATION5 PWTOATAX POWER SOURCE Project: WARNING f PHOTOVOLTAIC SYSTEM lEUT W SPECIFICATIONS DUNN RESIDENCE THISELECTRK SYSTEM ELECTRIC KHAZARD AC DISCONNECT OPERATINGCINiRENT:22.4AMPS 5 cnR1SER, WAY IS ALSO SERVED BYA HE DO CONDUCTORS OF THIS THISPHOTOVOLTAK SYSTEM OPERATING VOLTAGE:350 VOLTS NO JOB ANDOVER,G- 0 4 PHOTOVOLTAIC SYSTEM PHOTOVOLTAIC SYSTEM ARE EQUIPPED WITH RAPID SHUTDOWN OPERATING CURREM:53 NAPSMAX SYSTEM VOLTAGE 500 VOLTS JOB#:MA02 6-0024 UNGROUTA)EDAND MAY BE ENERGIZER OPERATING VOLTAGE 240 VOLTS MAX SYSTEM CURRENT:28 AMPS Prgect Details: WUT*WSPECIFICATIONS 10.791 kWstc, 10.00 kW AC REQ'D BY:NEC 705.12(l))(3) REQ'D BY:NEC G90.35(F) REQ'D BY:NEC G90.12 �� REQ'D BY:NEC 690.54 OPERATING CURRENT:8.4 NAPS APPLY TO: APPLY TO: APPLY TO: APPLY TO: OPERATING VOLTAGE:350 VOLTS MAX SYSTEM VOLTAGE 500V0T En eenn A oval: ANY/ALL ELECTRICAL PANELS JUNCTION 4 COMBINERS BOXES, PV SYSTEM MAIN AC DISCONNECT POINT OF INTERCONNECTION MAX SYSTEM CURRENT:10 5AMP5 9m ,3 ppr CONNECTED TO MULTIPLE POWER SOURCES DC DISCONNECTS,OTHER SERVICEABLE DEVICES REQ'D BY:NEC 690.54 APPLY TO: INVERTER#I REV1510N5 DE5CRIPPION DATE P.Ev ORIGINAL 1/21/2016 EQUIP RELOCATE 1/26/2016 B EQUIP RELOCATE 11 1/27/2016 C hcct T1tic: SAFETY PLACARDS heet Number: E2.0 Sheet 5— AN51 B - 17"x I I" SIGNAGE REQUIREMENTS JOEL HORRSTST /ESIG NtTING BY: /1//w— /� 1.)RED BACKGROUND 2.)WHITE LETTERING 3.)MIN.3/8"LETTER NEIGHT 4.)ALL CAPITAL LETTERS 5.)ARIAL OR 51MILAP FONT G.)WEATHER RESISTANT Reviewed t Approved by: MATERIAL,PER UL 969 SCALE: I"=4" EH Contractor: REVOLU(SUN aw�er.ememar.as a . POWER' • I NORTH AVENUE SOLARSUN WE BURLINGTON,MA 01803 E-SERIES SOLAR PANELS E-SERIES P:(781)270-6555 �p1 www.Ma55wJw5dts.Rzvok5un.con F SUNPOWER OFFERS THE BEST COMBINED POWER AND PRODUCT WARRANTY POWER WARRANTY PROOIICI wARRMIfY HIGH PERFORMANCE&EXCELLENT DURABILITY lava y, ! Protect: E O �r� DUNN RE51DENCE a rr,`7 Lily 5 CYIR15TIAN WAY -S ma NORTH ANDOVER,MA 01845 SERIES o a to is 20 u o a ID I,I m u JOB#:MA02_I G-0024 I' Men pu .j-d power.95%for W5 yvgry Combined Fb"am!PJndd ds4J 25 year wwp Protect Details: .20.4%e idency OA%/yw.te yea 25.s WrMalWas sat , aW.v 10.791 I,W5tc, 10.00 kW AC kleal for roob where span R at a pMbYutl ELECTRICAL DATA OPERATING CONDITION AND MSCI, J DATA ar where kAm elpansbn mVvt be needed. �. eife36 Temperature -40•C b 4150 Nomad Poeer1e Rnall) 327W 320W Weed:2400 Pp,2451�/na trust 6 back Engineering Approval: s High perbenaae E20-327 PM1d Power Tdeare 4S/-0% +5/-0% Mar lead Saar.5400 Pa,550 ka/.2Iron Delivers a cepent perfamesom N red weld M1.P.W Effid-'a 20.4% 19.8% 6p d-1,01 a 25r dower 6A d 23 vn/e conditions,such as high temperatures, HIGH EFFICIENCY* Rated Voltage(V vM 54.7 V 54.7v Appear- Ck-A clads and low 1ght.t23 Genemts mans energy per square m eler Rated Care/eppl 5.98 A 5.46 A Sam GW 96 Mawedyeo6u Mmwe Oa 1 0eslgned dentiol naofbpe,ESeAa E-Sww residential ponds cone m more sunkgh to elec" OpeeQra v Vokape(von) 64.9 v 64.6 v Temp"Gk. 190 kaaedelan mopered AwWWR*atve dolhd ho features.wluo and producing 36%more power per pans,'and 60%more energy per ShonCtrcu6 Gerdes prat 6.46 A 6.24 A Lela W,Bah IP6!Reed pan0b square meter over 25 years."A Alms.System Vohuge 10x0 v EC i 600 V Uraas MCU L Co. perfamanse Lor arty home. Mmdmum Series Fere 20A Frear Gas 1 Wank anodized IhWhedAAMA ratind HIGH ENERGY PRODUCTION' Pew.rT..PC.4. 0a6%/e I Weight 16,6 IQ Produra mom energy per mind wan Va mete Tww Cos. -176.6mV/-C High year ane parfomonoe dell ea 7,9%more energy per rated Currem Tsep Cast. 3.5 mA/C TESTS AND CF1fFlG1T10N5 wcti.a This Is;hmn ge w4moses oar Ems,pnodudrp 20%more _siadard trh IEC 61215,EC 61730.111703 ->.. energy over the pat 25 years to meet your needs! 1 AT cornpodiane ae 31111420nW w a repesriaM car Amd QuatiY Tei 150 9001:2001.150 14001:2004 REV1510N 5 paeh 240N,epp w I A ma,15%atide c, fillsOa^PA^ee 00 6aHi,OHSAS 181:2007,Ised Lee, DESCM-oN DATE REV 2 Wcy EmMicri Lmiis`5urf wyyf Se ,•F&201& WCycle ORIGINAL I/21/20IG A 3 TWA.* rv.n energy per xdl BEWANN FIVkntring ldbwer bAeYlmata me IEC 62716 EQUIP RELOCATE 1/26/2016 B �_-6A.`y Mr6eed. yiwftpwt,Jm2013. EQUIP RELOCATE II 1/27/2016 c aer4y 4 S nlboer 0.2S%,*1sp edNan va 1.0%ryn spin.pomE Cm psa,L Sat Spay 111-dMer IEC 61701 d-W-sw.Y) r iaer..d lar ladavmo.dasgead 6.&rm6tisy. 20a� aa.-sr Pb--Ma1.IIw-pndolat 11hWsmdewerwMrp*psr Fvb nerd PdawdYdueed fahgirraed for pease al marc 1I o% w Rued wan 25'Sunf- Til itis'3.w-vIdA�sipq.q F b �OAed°Pohh has 1000V'v 12Ox Men EneryY labile Ids TW,MCS,IR,JET.KEMCO.CSA,CEG FSEC Designerd to dekva consistent,h oL"a4me DDx C%°°'•Y i� 2013.1L11F86 9P ow.1100 parir opwai e d momrI.70%ot sinew over a very bag l"I3m." � +- __ leh.d paver. Designed br y0% 35x mus. 6 Oat of d 2600 pari I.sd im M.A.n keeneriava4 Rb 2012. The SunPower Solar Cep b the eox ---_ -__,__:.,r°`zS n 2012(1st ,102 p.*O,,P Int,10 1Oirh.fid,Meldr 2GI3 Isowd sheet Tlde: 6 Camped'IRA Rrbp 16 mallrkakww SunPaxr W.raty RevMn 1046 mm only owl bwkanasolid copper fourdanow. 7D% $T i 17TrTjl Nib 2013. r �� PV MODULE Vtmhally Impervious to the corrosion and 6o% 9 s°m W d-vppy.3-weneeN frdlvkill. craddhg that degrade Cmmmrttional 520%' 105 d by i part se ivck.e.nnherhed by haw'.PK6E,'W DATA 5HEET Parrle.'A 0 5 10 15 20 25 AAo"Dw bAV k*a-KJA.Repack•Fb 2013. to Yom 11 Cavpadvaih to rvsra.vivertrdasladp°Tel.Mia 25i o.aWtt7 46--j 1559rm Sheet Number: 111 Ranked In Fratnhdia dumbfpy het. D% ter npak Feb 2013. 100%parwr molnbhed in Atba 25' M°N°1e.Mat °s1Of?v, 12 5ladod AstCatdillae(1000 W/na tmodlms,AM I A 25'M D .0 -"Pfd-Per(Dumbi6y toal.l' ex Pow«!Koh ramp. �1.' 13 Band m ovsaw o1 mseed Pa rvakw dudm Padw6an I Ne us' l lox 1 Sheet 5ae: 6% �I°ea'�K°" � � ANSI B - 17" x I I" High M- Ybtl �a 4% BMr(°wlleFl and 5i 3pur°I feµnwDESIGN<DRAFTING BY: 216 Highvefw°uo<. JOEL t10R5T �l+e- b Mllt.ncho.ow.. a.1.oJh..uwre.alpalytsaraam..stew kdn.rm y^ ox r.rlvlwvkai,wevbdd Wer:sw.s.�wwyanyd+.lev.lYd.Ybsrli inli/wl MlucbskioldlnKp°ila. ew�amaww�a.rr.aMNrlwwLvuealn�Mwesorery.,wluo14 r6.wee.raaa,.varwMn�..vd..h....t+.r f+CrAC'Crp ..nerd.dew.a.r+�►+w.rrvrrw.4.rs.+..Wrr.tl.wwr....lre C�i._.C1Ul�Cl tiunprywereorp.eom Reviewed k Approved by: Eli Contractor: REVOLU(SUN CbaMr,emerrx.alar. I NORTH AVENUE _ BURUNGTON,MA 01803 solar • S sIOJIe Phase InVertersforNorthAmerlca P:(781)270-6555 solar 0 @ SE3000A-US/SE380OA-US/SE5000A-US/SE600DA-US/ yyAy,M��y�GhuSettS.Rev01u5M.Lan S E7600A-USI SE10000A-US/SE11400A-US SE30o0A-US SE3800A-US I SE8000A-Us TSE6000A-ut s E76a0w-u5 I SFfOrnw-us scffarme.u< OUTPUT SolarEdge Single Phase Inverters NomMaI AC Powe O put 3000 3800 5000 6000 600 99NnV)nAV ISa00 YA ................................................................ /. .�/ .. Sqm 4p AWV 11WN140 For North America Max.AC Power Output 3300 4150 -00 8350 12000 VA ...........................................................................545.9.C4344Y...................................}.4459.07..4!!.............................. Pro ect: AC Output Voltage Min:Nrxn;Mawlo ✓ J SE3000A-US/SE3800A-US/SE5000A-US1SE6000A-US/ A3 zoA-2z9vac DUNNRE5IDENCE .....,tolt............................................................................................................................................................. 5 CFI RISTIAN WAY AC Outpu[VOltaee Mirx•Num:Max.°' .1 ✓ , ' SE760OA-US/SE1000OA-US/SE1140OA-US l]-2ao.z6ava[ NORTH ANDOVER,MAO 1845 .........................................................................593-........................................................................................... AC Frequency Min:Nom.-Max."I 59.3-0,0.5(with Hl counvyse!nn#57;60:0;5)., Nz JOB k:MAOI 16-0024 241a 208V a8 @ 200V M C X Dutp iru 125 1G 25 37 4]5 A .. ,,...,..... .?1.0.7a4v I I. IAP.mpv ( Protect Details: GFDI TI I IV .. ..................................................... ......... ......... A 7 unary-Mnnurclglaandl�i r..mm.cn t r hh,mx _y« Y._s 10.791 kWstc. I0.00 kW AC INPUT Maximwn DC PoweI ISTC( 400 510 6750 810 30250 1950 15350 W ............................................................................................................. aa� ........................... Iramlarmnrless.Un ......................... .................................. ...Yes I. .Maw)npuUr.°1�.4!..................... `+� We Engineering Approva ,�.�8 ..................................................................................................................................... 0"`) Noni..Of Input,WItaBE............................................................32'40,208V(3i0.,2�OV Vdc 16.5 Q3208Y ...... - 33®208V • Max.Input Current"' •9.5 13 18 23 34.5 Al ............................................ ......I. ......I.x5�5 f^249Y..I................................I..3D.5 A?x9p.Y..I.................... ...... . Input Shat Orcub[ulmnt •...............a5 ...................................................................................... ................................................................... 8 ,. ,peverse.Poledty Protection fiOfM SensltivirY .................................................... : :+ G�aunJ FaWtivManan Oetallon.... ............................................................. ��' Maxbnuml LlAcla y ,,,,,,97;7,,,,,., 982 983 98.3 98 98 98 % ................... ........................ CFC Wei9A Tf dEfHlen[y 5v/.Y�2IIftY ..................9�....... '. t8 httime Power[onsum tbn <2.5 <4 W ADDITIONAL FEATURES Supported Cpmmunkatbn lnterfa<Ps RW 85,RS232,Ethernet,L40eelmlllPlull................................................. .............................................................................................................. novenae Grade W tor,AN51 C12.1 Optionall" 41 �: Aapltl Amtdown-NEC 2014690.12 Funcnorwllly elubletl kit is Nrstalletln' STANDARD COMPLIANCE R i vtety.. ..... ..................... UL]]a1,UL1E990, . U11998 CSA 222 DESCKIPTION EV ONS DATE KEV Grid ConnecXm SDntlartls ICEE159] ............................................................... ORIGINAL 1/21/2016 A INSTALLATION t,' iom K[eartlS CGas e EB INSTALLATION SPECIfICAT10N5 QUIP RE.00ATE I 1/26/201 G A[out ut Pntlult alae AWG ran EQUIP KELOCATE II 1/27/2016 C p / 34"minlmum ]6�6 AWG [ �e ( / 9/A"minlmum/8-9 AWG ...............d............f....... ............................. .................../11,................................./4'............ . OC Input contlult sizn/Mo/itrin8s/ 3/I•minlmum/1-2 strings/�� ` AWGr ................................................................./9-minlmum/1-2srnn6s/1hG AWG oimmslons•with Safety Swimh ••••••••....••...••••.••••30.5 12AV 1............ 3n.5x12.5x%.1/775,315x 1Na 30.Sx12.5x 10.5/ In J ..(HFWvpf............................................................................................................................//h y:;ly.7.Ml............,mm.... 23:?..........I......................50:7/24:x.... ...............tl8:4(. :1 ....�C/!'9... M i1 ...Naweal. ......... Cooling Natural Cawectieo too 11-141 Fans(uscrrepl—ble) Sheet Title: f."`""`1) PV INVERTER The best choice for SolarEdge enabled systems ........................................................................................................P,c,able........................................... rc I e N lore �° F/' DATA SHEET Integrated efficiency (98-Aection(Type 11 for NEC 2011690.11 compliance MI11:Max.(ryeraMgTemperature ...to.140/-25 to a0(-a0to.60-sion awllable''<) 'F/-C Superiorefflcienq(98'6) ..!Wnee....................................................................................................................................................................... PmtecXm NaXng NEMA 3N ,..,...... Sheet Number: -Small,lightweight and easy to install on Provided bracket ................................................................................................................................................................... -Built-in module-level monitoring �maai>.a�ow.�mXsoww..wa.an� .�ea:�a,�we��.ra.ewA.,MFwnw Paan.Mlew.wG..an.a. D2.0 � m..i,�n vMPi[ioaoawilNlu 1 �4P01YInM{I:X76LOaYXg1NN411. -Internet connection through Ethernet or Wireless ,<, a/x:w,..e�woonwauw naoe�...waenaw.uwasxewgL -Outdoor and indoor installation Sheet Sae: -fixed voltage inverter,DC/AC conversion only ANSI 13 — 17"X I 111 -Pre-assembled Safety Switch for faster installation -Optional-revenue grade date,ANSI C12.1 DESIGN t DRAFTING BY: • JOEL NORST USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredge.us SEPIS0LAR Reviewed 4 Approved by: Eh Contractor: REVOLU(SUN! tle��er,smarter.inlay. I NORTH AVENUE $O�al' ® ® � Solar ® ® � SolarEdge Power Optimizer BURLII 81ON2,M0 01803 Module Add-On for North America wwv.Ma55achu5ett5.Revo1u5un.com P300/ P320/ P400/ P405 SolarEdge Power Optimizer P320 P400 P405 P300 Im.nkbyow.r IternrsOteO Ror tnln ran (W6o as nioduies) 66rall msduks) moduks maduks) Module Add-On For North America WLI - -- Protect: RatedlnputDC•Power<'� ..._......300 ,..,,,..,,320 ........,-400 ...........m5 ,,,,�N DUNN RE5IDENCE P300 / P320 / P400 / P405 Absolute Maximum Input Voltag` 48 80 125 Vdc 5 CHRISTIAN WAY (Voc at lowest temperatpre)..........., ,,. NORTH ANDOVER,MA 01845 ........................................................................................................................... MPPT Operatin&Range 8-48 8-80 12.5-105 Vdc JOB#:MA02 1G-0024 ........... ..................................................................................................................................... - Maximum Short Circuit Current put 30 I 11 10 Adc ............................................................................................................................................................................. Maximum DC Input Currant 12.5 13.75 12.5 Adc Protect Details: ....axim.....ffic ........................................................................................................................................... ® Maximum EfBciencl'.......................... .............tJ9:`'.............................................................°(:...... 10.79 1 kW5tc. 10.00 kW AC ..................................... Weighted EfBciencY.. .........................................................................98 ............................... :g ............................�...... OVervolta a Cate o II OUTPUT DURING OPERATION POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) _ —`-- -- Engmeenng Maximum Output Current .15 Adc Approval: Maximum Output Voltage GO 85 —Rd" OUTPUT DURING STANDBY POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF Safety output voltage per Power ® Optimizer i Vdc STANDARD COMPLIANCE ' -' EMCFCC Part1S Class 8,IECG3000-6-2,IECG1000•G•3 ............................................................................................ .. .. ............................. ......... ZJTer+ Safe!y......................................................................... IEC62109-1(class 11 safetYh,UL1741............................. ........ Wt» -ROM ............... Yes_ _ i` INSTALLATION SPECIFICATIONS Maximum Allowed System Volta&.........................................................1 ..........................................................Vdc..... Compabble myereers,,, - All SolarEdge Single Phase and Three Phase iiwerters ,,, Dimensions JW x L x H) 128x 152 x 27.5 128x152x35/ 328x152 x 48/ mm/in / 5x 5.97x 1.08 5x5.97 x137 Sz 5.97x 1.89 REVISIONS 770/1.7 930/,2A5......,......._930/2;05__,.,.-,.,.gf/Ib.... DE5C11Pr1ON DATE REV F .... ................................. Octor ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,•„.MC4 Compatible. .............. oRlcieu 11211201 6 A OutputWreType/Connenter DOUbk Insulated MC4 Co patible EQUIP RELOCATE 1/26/2016 B Output Wl lxogth „0.9530 I.... .7.2/39 .. m.(([ EQUIP RELOCATE II 1/272016 C ..Operating Temperature Range....,.. ......... I ....................40:+85_(.40:+185,, ................................'C%'F.... Protectipn Rating........... ......... .....IP68..NEMA6P............................................................ ..................................... .......... .. Rclat(ve.HumlduY......................... 0.100 '1b..... ........................................................................................................................... :ww srz w�.•a m..we.u.nieem.a.o w.rw oa.+•uu..vr..uw++. PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 203V THREE PHASE 480V A SOLAREDGE INVERTER- 5heet Title: Minimum String Length g 10 18 OPTIMIZER (Power OpNmizen)...... ................... PV ower optimization at the module-level Maximum s'"ing Length 25 2s s0 DATA SI IEET PP (Power optimizers)................................................................................................................................................. "I.M heet Number: Up[025%more energy Maximum Power per,5tring.•„••.....................5750 6000 ....••„••„,12750 W,,,, ......................... ..............................Yes................ ...................... Superior efficiency(99.5% Parallel Strings of Olgerent Lengths D3.0 P ) or Orientations .............................................................................................................................. ..Orie..................................... Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading �.xL.a.la..aem1.v.os.m�vmry<«vveao/v>ooi��e..a,m,. 51­t t 5¢e: - Flexible system design for maximum space utilization ANSI B - 17”X I III fast installation with a single bolt Next generation maintenance with module-level monitoring DE51GN x DRAFTING BY:JOEL t10RST - Module-level voltage shutdown for installer and firefighter safely USA GERMANY ITALY FRANCE JAPAN CHINA ISRAEL AUSTRALIA WWW.SOIaredge.uS �•- �.•_•- •• .Cf'C��l 5EPISOLAR Reviewed t Approved EIY: EH Contractor: REVOLU(SUN I NORTH AVENUE BURLINGTON,MAO 1803 P:(781)270-6555 215° wvnv.Ma55achu5ett5.Revo45un.com Pro ect: DUNN RE5IDENCE 5 CHRISTIAN WAY NORTH ANDOVER,MA O 1 845 JOB#:MA02 1 G-0024 Project Details: 10.791 kW5tc, 10.00 kW AC Englneenng Approval: REV1510N5 Ot5CPJPTION DATE INEV ORIGINAL !/21/2016 I A EQVIP RELOCATE I 1/26/2016 B EQUIP RELOCATE II 1/27/2016 C Sheet Title: OPTIMIZER SHEET Sheet Number: 5heet 5¢e: ANSI B - 17"x I I" ESIGN t DRAFTING BY: /) JOEL HORST //[J SEPI Reviewed 6 Approved by: EH Date. NO'R°T:��o TOWN OF NORTH ANDOVER o p PERMIT FOR PLUMBING '� ,, -�,,r.o•'"try ,SSAGMUS� This certifies that 1 .11. J .7% . . . . . . . . . . . . . . . . . . . . . . . . has permission to perform . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . plumbing in the buildings of . L,— . . . . . . . . . . . . . . . . . . . . . . . . . . . , North Andover, Mass. t�L � r Fee.3� . . . . . .Lic. N0.. .�:�. ?.`. . . . . . . . .,.f, . . L-.� �.�� . . . . . . PLUMBING INSPECTOR Check # Jud ! i/ ' Location a No. / r Date HQRTq TOWN OF NORTH ANDOVER Of «•O ,•,h•Q y Certificate of Occupancy $ • i � Building/Frame Permit Fee $ SgCMus Foundation Permit Fee $ Other Permit Fee $ TOTAL $ D� r Check # y i 'r Building Inspector TOWN OF NORTH ANDOVER BUILDING DEPARTMENT APPLICATION TO CONSTRUCT REPAIR,RENOVATE, OR DEMOLISH A ONE OR TWO FAMILY DWELLING BUILDING PERMIT NUMBER. 1716DATE ISSUED: SIGNATURE: Building Commissioner/Inspector of Buildings Date Z SECTION i-SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map and Parcel Number: S 6#4-1-14AI A141Y /09 b 0/143 Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Areas Frontage ft 1.6 BUILDING SETBACKS ft Front Yard Side Yard Rear Yard Required Provide R 'redProvided Required Provided 1.7 Water Supply M.G.L.C.40. 54) 1.5. Flood Zone Information: 1.8 Sewerage Disposal System: Public ❑ Private ❑ Zone Outside Flood Zone ❑ Municipal 0 On Site Disposal System 0 SECTION 2-PROPERTY OWNERSHIP/AUTHORIZEDAGENT HistoricDistrict: Yes NO rn 2.1 Owner of Record Name(Print) Address for Service: f Signature Telephone N< 2.2 Owner of Record: Name Print Address for Service: z ~ rn Signature Telephone SECTION 3-CONSTRUCTION SERVICES 90 3.1 Licensed Construction Supervisor: Not Applicable ❑ a Licensed Construction Supervisor: Z 4 Q 11 �0 License Number 0" Addres f� � � /� � �O S Expiration Date Stgga46e Telephone 3.2 Registered Home Improvement Contractor Not Applicable ❑ /may Company Name yyt t Z 64445Registration NumberrM r Address GZ � ) /'97�37�GoGlt Expiration Date Z Si na re �✓y(✓ Telephone m)n r SECTION 4-WORKERS COMPENSATION(M.G.L C 152 § 25c(6) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed affidavit Attached Yes.......❑ No.......❑ SECTION 5 Description of Proposed Work check all applicable) New Construction 9d Existing Building ❑ Repair(s) ❑ Alterations(s) ❑ J Addition ❑ Accessory Bldg. ❑ Demolition Other ❑ Specify Brief Description of Proposed Work: jeemovx aGs Ptd , Bvizo NE IA/ &/X 34 J4' X /1'.` Tn AF— W17-14 r/a ROOF AR,',b IJ✓ SECTION 6-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollar)to be OFFICIAL USE ONLY Completed by permit applicant 1. Building j d a (a) Building Permit Fee Multiplier 2 Electrical (b) Estimated Total Cost of Construction / 3 Plumbing Building Permit fee(a)X (b) - 4 Mechanical (HVAC)E� 5 Fire Protection 6 Total 1+2+3+4+5 Q QO Check Number SECTION 7a OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER-S4GENT OR CONTRACTO LIES FOR BUILDING PERMIT I> as Owner/Authorized Agent of subject property Hereby authorize to act on My behalf,in all matters relative to work authorized by this building permit application. 6 / -Signature of Owner Date11 SECTION 7b OWNER/AUTHORIZED AGENT DECLARATION f I> as Owner/Authorized Agent of subject property Hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief Print Name Signature of Owner/Agent Date I 111M INN 11 NO. OF STORIES SIZE BASEMENT OR SLAB SIZE OF FLOOR TMIBERS 1 ST2ND 3RD SPAN DIMENSIONS OF SILLS DIMENSIONS OF POSTS DIN ENSIONS OF GIRDERS ' HEIGHT OF FOUNDATION THICKNESS SIZE OF FOOTING X MATERIAL OF CHRvINEY IS BUILDING ON SOLID OR FILLED LAND IS BUILDING CONNECTED TO NATURAL GAS LINE I s xzz xz.z r'.,I ',l 1.11 Don - '�� r' �/ ✓' ►its �`� '� h�� bE� y ������� Z�XIv� S(3i�"T IZ17 Q.e� p ps+o pEC t4Al - D�c!G _,.-------- i Z x 1�Yf1=7"�k'S >z I ' l 4,Y4 P®Sl-:5, y,�,° - - ,wally bulw, Aj- 14 t4. 71 Sl`e 3::€ 30L Z�t.ZL aener�v = a The Commonwealth of Massachusetts - u r _. Department of Industrial Accidents � d Office of Investigations w Boston, Mass. 02111 Workers'Compensation Insurance Affidavit Name Please Print Name: Location: City Phone # I am a homeowner performing all work myself. I am a sole proprietor and have no one working in any capacity I am an employer providing workers' compensation for my employees working on this job. Company name: Address City Phone#: Insurance.Co. Policv# Company name: In (_V Address G` Citi 11911ef— H14-1- M14. (It F3 2- Phone#: Insurance Co. J?AgeFFe2E� /ny1p4l, S/1J5 . Policv# e DPe/DO 6r7// Z6 Failure to secure coverage as required under Section 25A or MGL 152 can lead to the imposition of criminal penalties of,a fine up to$1,500.00 andlor one years'imprisonment as.wellas_civil.penaftiesinJheform of-aSTOP WORK_ORDER..and_a fine_of.(.$1D0.00.)._aslay.against.me. 1 understand that a copy of this statement may be forwarded to the Office of Investigations of the DIA for coverage verification. I do hereby certify under the pains and penalties of perjury that the information provided above is true and correct. Signature Date Print name Phone# Official use only do not write in this area to be completed by city or town official' City or Town Permit/Licensing ❑ Building Dept ❑Check if immediate response is required ❑ Licensing Board ❑ Selectman's Office Contact person: Phone#: ❑ Health Department ❑ Other ZZ5,C.O r �v i 400 i I. jl I i i i{ �!i!:i'• IV .II;! ! •, ,• it Vit) '� •n . ,. .r li LOTS57078 Tf.ri i I• .� j ii =i 1 I.. � i 1 ' d:'. � is,'lu�l•,': .!' .,51 St� r. ¢r' �ip i:.� I'Ji ,\' :I`•I �'' '',� 'I - `•� F T. Z i CL •�1 ! Ir '. i �'. 'I is t i l� . . Y�� i:ri Jl .'•�t i i•�; )� .1 -�'.� �. :i t1; 1, �ir�•„il•?!�: - u� . •7`;it „'�. '�'.;. Ij: ,. :. .I ,51,, + ; , i..:.17 �'1E�•• 1ii Z° CHRISTIAN • 1 i I.I �� �� �bb1 � I . a Q A YO~A' a 8 OYTiY s��r -' rrrvrcr. ,oau�4rrr�c►viw 4WOOZZOW �141STE�� l7TiS/ ANAt�VEI�j MASS, .�oiaWrtu AW-4,0eAl 090- W NO o Q ao aw�E s•tis-8a) � .' AL FREQ d- D/IgNE &p r K/N efro, �ATilAi7b►(M'.!vr I�1 lrIJYiMI!'ry� S-'N. OsTwrf�c •+. n� . �"=9br�',c,rIG.tT'ltt�lIERMr!!l :AMNA��C WE0011A, .1HfF�, Ii99f�/ M-Z5714o . � eftW� p lI /” / � • v- , ' 11444. P t .001 .11Nt.�iA�r^1�'m' a�t/•to 6143 1 FORM U - LOT RELEASE FORM f INSTRUCTIONS: This form is used to verify that all necessary approvals/permits from Boards and Departments having jurisdiction have been obtained. This does not relieve S the applicant and/or landowner from compliance with any applicable or requirements. *****************************APPLICANT FILLS OUT THIS SECTION*********************** APPLICANT R14YInOlV> 5j-F,41 Jh7-tVb PHONE `1 dk 374-01,45 LOCATION: Assessor's Map Number PARCEL W,! 3 SUBDIVISION LOT (S) STREET e"7 ffk/ST/)W 1i ST. NUMBER *****************************************OFFICIAL USE RECO ENDATIONSFST WN AGENTS: CONSERVATION ADMINIST OR DATE APPROVED a/ DATE REJECTED COMMENTS TOWN PLANNER DATE APPROVED . DATE REJECTED COMMENTS FOOD INSPECTOR-HEALTH DATE APPROVED DATE REJECTED SEPTIC INSPECTOR-HEALTH DATE APPROVED DATE REJECTED COMMENTS PUBLIC WORKS -SEWER/WATER CONNECTIONS DRIVEWAY PERMIT FIRE DEPARTMENT RECEIVED BY BUILDING INSPECTOR DATE Revised 9197 jm r ✓fze Ui anvnwnu�,a��✓li/,aara�cluurel�a � BOARD OF BUILDIN REGULATIONS License: CONSTRUCTION SUPERVISOR ZIA d Number: CS 053532 I Birthdate: 05/15/1961 Expires:05/15/2005 Tr.no: 10988 .. .r Restricted: 00 RAYMOND D STAMAND 21 HOWE ST#17 - METHUEN, MA 01844 Administrator i North Andover Building Department Tel: 978-688-9545 DEBRIS DISPOSAL FORM In accordance with the provision of MGL c 40 S 54, a condition of Building Permit Number is that the debris resulting from this work shall be disposed of in a properly licensed solid waste disposal facility as defined by MGL c 11, S 150 A. The debris will be disposed of in: (Location of Facility) Signature of Permit Applicant Date NOTE: Demolition permit from the Town of North Andover must be obtained for this project through the Office of the Building Inspector �.10RTIy TO'" Of No. (� o� �` dower Mass., _4 3 0 LAK COCHICKEWICK A00ATEO S V ` BOARD OF HEALTH PERMIT T D Food/Kitchen Septic System qu • `� BUILDING INSPECTOR THIS CERTIFIES THAT...,..Q.� ............... .............�............e. �i .................................................. Foundation has permission to erect....` !..�...... buildings on .....�......C A. ./..l olam....wA...Y Rough to be occupied as........ j..As...D.t..C.k...i..., ......S ..h�. ..•......4..t.........P......I... ^t Chimney .... ......... ..... ... ..... . provided that the person accepting this permit shall in every respect conform to the terms of the application on file in Final this office, and to the provisions of the Codes and By-Laws r lating to the Insp7 /00400W n, Alteration and Construction of Buildings in the Town of North Andover. ,r y D 7i y3 PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough Final PERMIT EXPIRES IN 6 MONTHS ELECTRICAL INSPECTOR UNLESS CONSTRUCTIO ST T w Rough Service B LDING INSPECTOR Final Occupancy Permit Required to Occupy Building GAS INSPECTOR Rough Display in a Conspicuous Place on the Premises — Do Not Remove Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. SEE REVERSE SIDE Smoke Det. 3L �' MASSACHUSETTS UNIFORM APPLICATION FOR PERMIT TO DO PLUMBING (Print or Type) /� I-h o4ndaiae-r:Mass. DateL3 0 Permit #_ a. Building Location. � r�S'T'� Owner's Name '0 I � Type of Occupancy. Residential New ❑ Renovation ❑ Replacement Plans Submitted: Yes❑ No ❑ FIXTURES Z �flQ� . N Z h_ Q lJ Z Y N fn N O Z 'n Z vi Q K ¢ = cl:h N Z O — 2 Z a 49 W T Q ¢ W N a d 4 C W4 U Z Q ID 2 N W > h ,/I — 0 Q y Z c as 4 j R W O 7 W Q (n ac ¢ J N ¢ J _ O O W W CL > ►_- O = a N 3 z o o N z z W h 0 3 x -j m N o o j 3 = N W W D o a 3 cai td rd rd td Q SUB—BSMT. BASEMENT Q IST FLOOR 2ND FLOOR 3RD FLOOR 4TH FLOOR STH FLOOR 6TH FLOOR 7TH FLOOR STH FLOOR Installing Company Name Heritage Htg. &Pig. CO. Inc. Check one: Certificate Address 35 Pleasant Street IX Corporation 714 Stoneham, Ma. 02180 ❑ Partnership Business Telephone 781 —43 3 B-77 76 F1 Firm/Co. Name of Licensed Plumber Gordon Switzer INSURANCE COVERAGE: I have a current liability insurance policy or its substantial equivalent which meets the requirements of MGL Ch. 142. Yes ® No ❑ If you have checked ryes, please indicate the type coverage by checking the appropriate box. A liability Insurance policy IN Other type of Indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the Insurance coverage required by Chapter 142 of the Mass. General Laws, and that my signature on this permit application waives this requirement. Check one: Owner El Agent❑ Signature of Owner or Owner's Agent 1 hereby certify that all of the details and information I have submitted(or entered)in above application are true and accurate to the best of my knowledge and that all plumbing work and installations performed under the permit issued for this application will be in compliance with all pertinent provisions of the Massachusetts State Plumbing Code and Chapter JA9 of the General Laws. By_ Signature of Ucengbdum er Title Type of License: Master[A Journeyman❑ City/Town 8322 APPROVE Ucense Number i BELOW FOR OFFICE USE ONLY FINAL INSPECTIONS SKETCHES PROGRESS INSPECTIONS FEE NO. APPLICATION FOR PERMIT TO DO PLUMBING NAME&TYPE OF BUILDING LOCATION OF BUILDING PLUMBER PERMIT GRANTED DATE 19 PLUMBING INSPECTOR I C NORTH � � E Town of over 0 oH dover, Mass., 19 AORATED P'f I 'qs H BOARD OF HEALTH Food/Kitchen PERMIT T Septic System THIS CERTIFIES THAT... L..41.. L FoundationDING INSPECTOR BUIL has permission to erect. A................ buildings on ..� �. � � ... •••• Rough to be occupied as..00.40.06;. e.0.9).A..40 .A0P.V...4eQ:a�00. li����►, Chimney C e provided that the person accepting this permit shall in every respect conform to the terms of the app n on file in Final this office, and to the provisions of the Codes and By-Laws relating to the Inspection, Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough PERMIT EXPIRES IN 6 MONTHS Final UNLESS CONSTRUCTION STARTS ELECTRICAL INSPECTOR Rough Service BUILDING INSPECTOR Final Occupancy Permit Required to Occupy Building GAS INSPECTOR Display in a Conspicuous Place on the Premises — Do Not Remove Rough Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner PLANNING FINAL CONSERVATION FINAL Street No. Smoke Det. nrern „A1ATr-r, 1:1RIA1 �� t1RwC:\A►AV FniTRV PERMIT _ _ ,�I_ocation -77 _ - IVo. - Date "T►, TOWN OF NORTH ANDOVER p Certificate of Occupancy $ Building/Frame Permit Fee $ 'sJ,�►asE`�i FoundatioA Permit fee $ OtherG`Permit Fee"'' $ f `ewer Connection Fee $ ~ V1Fr;Connection Fee $ Building Inspector r ) r `- 4r% Div. Public Works e a P,Et•,%Trfi NO. � APPLICATION FOR PERMIT TO BUILD — NORTH ANDOVER, MASS. VIPAGE 1 MAP 4-40. LOT NO. 2 RECORD OF OWNERSHIP JDATE BOOK '.PAGE ZONE SUB DIV. LOT NO. —I LOCATION /�/_�Slh )may PURPOSE OF BUILDING OWNER'S NAME /_ /1�LIN� &1 & '1� ���� NO. OF STORIES SIZE OWNER'S ADDRESCCSYY�'fm�FF/1 1 J/llViA6dd% LJ BASEMENT OR SLAB ARCHITECT'S NAME V v SIZE OF FLOOR TIMBERS 1ST 2ND 3RD . � V _•'• BUILDER'S NAME C SPAN - I _ DISTANCE TO NEAREST BUILDING DIMENSIONS OF SILLS '-- DISTANCE FROM STREET POSTS DISTANCE FROM LOT LINES-SIDES REAR �� GIRDERS AREA OF LOT 457� O S.P. FRONTAGE HEIGHT OF FOUNDATION THICKNESS IS BUILDING NEW Y SIZE OF FOOTING M X o IS BUILDING ADDITION yer MATERIAL OF CHIMNEY IS BUILDING ALTERATION IS BUILDING ON SOLID OR FILLED LAND WILL BUILDING CONFORM TO REQUIREMENTS OF CODE yGs IS BUILDING CONNECTED TO TOWN WATER BOARD OF APPEALS ACTION. IF ANY IS BUILDING CONNECTED TO TOWN SEWER IS BUILDING CONNECTED TO NATURAL GAS LINE INSTRUCTIONS a PROPERTY INFORMATION LAND COST SEE BOTH SIDES E8T. BLDG. COST 3 oaf PAGE t FILL OUT SECTIONS 1 - 3 EST. BLDG. COST PER 64. FT. PAGE 2 FILL OUT SECTIONS 1 - 12 EST. BLDG. COST PER ROOM SEPTIC PERMIT NO. 1` ELECTRIC METERS MUST BE ON OUTSIDE OF BUILDING 4 APPROVED BY * ATTACHED GARAGES MUST CONFORM TO STATE FIRE REGULATIONS PLAN M ST BE FILED AND APPROVED BY BUILDING INSPECTOR r DAT FI ED [f BOARD OF HEALTH 8;G-"r OF OW ER OR AUT � 1 D AGENT �l�t� PERMIT GRANTED OWNER TEL. PLANNING BOARD � CONTR.TEL (430-d,�X 2e l�il 19 ->��-- (, TR.LIC.#--.Ili !?g c. BOARD OF SELECTMEN . 31�Gr So' �� /1 BUI INd INiPtCTOR h , BUILDING RECORD 1 OCCUPANCY 12 SINGLE FAMILY Si Ok IES THIS SECTION MUST SHOW EXACT DIMENSIONS OF LOT AND DISTANCE FROM MULTI. FAMILY OFFICES LOT LINES AND EXACT DIMENSIONS OF BUILDINGS. WITH PORCHES. GA- APARTMENTS RAGES. ETC. SUPERIMPOSED. THIS REPLACES PLOT PLAN. CONSTRUCTION 2 FOUNDATION 8 INTERIOR FINISH CONCRETE d I 2 13 CONCRETE BL'K. PINE _ BRICK OR STONE HARDW D PIERS PLASTER _ DRY WALL _ UNFIN. 3 BASEMENT AREA FULL FIN. B M'T' AREA _ V, 1/7 l/ FIN. ATTIC AREA _ N_O B M FIRE PLACES _ HEAD ROOM MODERN KITCHEN 4 WALLS I 9 FLOORS CLAPBOARDS B 1 2 3 DROP SIDING CONCRETE �_ WOOD SHINGLES EARTH _ ASPHALT SIDING HARDW'D _ ASBESTOS SIDING COMfACN _ VERT. SIDING ASPH. TILE _ STUCCO ON MASONRY _ STUCCO ON FRAME BRICK N MASONRY ATTIC STRS. d FLOOR I_ BRICK ON FRAME CONC. OR CINDER BLK. STONE ON MASONRY WIRING STONE ON FRAME _ SUPERIOR I� POOR 1 11 ADEQUATE NONE 11 5 ROOF 10 PLUMBING f GABLE I HIP BATH (3 FIX.) GAMBRELMANSARD TOILET RM. (2 FIX.) _ FLAT A SHED WATER CLOSET _ ASPHALT SHINGLES LAVATORY _ WOOD SHINGES KITCHEN SINK SLATE NO PLUMBING _ TAR & GRAVEL STALL SHOWER _ ROLL ROOFING MODERN FIX7URE5 _ TILE FLOOR TILE DADO 6 FRAMING 11 HEATING WOOD JOIST PIPELESS FURNACE FORCED HOT AIR FURN. TIMBER BMS. &COLS. STEAM STEEL BMS. & COLS. HOT W'T'R OR VAPOR WOOD RAFTERS AIR CONDITIONING RADIANT H'T'G '- UNIT HEATERS 7 NO. OF ROOMS GAS OIL B'M'T 2nd _ ELECTRIC 1st 13rd 11 NO HEATING r FORM U - LOT RELEASE FORM + � INSTRUCTIONS: This form is used to verify that all necessary approvals/permits from Boards and Departments having jurisdiction have been obtained. This does not relieve the applicant and/or landowner from compliance with any applicable local or state law, regulations or requirements. ****************Applicant fills out this section***************** APPLICANT: - k-i& Phone( 3d ! -� LOCATION: Assessor's Map Number J Parcel 1-i3 Subdivision Tyy-fi. (� Gst&ims Lot(s) 4?- Street ChnsSt. Number ' ************************Official 4se Only************************ RECO DAONF TO AGA- zw_.� Date Approvedonce a i Date Rejected Comments Date Approved Town Planner Date Rejected Comments Date Approved Food Inspector-Health Date Rejected Z// SDate Approved Septic Inspector-Health Date Rejected Comments PeC4C Public Works - sewer/water connections - driveway permit Fire Department Received by Building Inspector Date Note' With vinyl or aluminum siding, the band may be bolted directly to the house without flashing or removal of siding. 2 x 2 Tr Im 5/4 x 6 Cap •-2x4Pal i 6" 2 x 2 Pickets (6" o.c.) Exterior Wall .- 4 x 4 Rall post (wood or Masonite) (max. 5' o.c.) 5/4 x 6 Decking Flashing 2x4Pall � (�� 2 x 8 Joists e 162x8ILI " o.c. House Band . 3/8 x 4"Carriage Bolt lJolst hanger,,**' 1 x 4 Trim --(2)2 x 10 Beam El eva t Ion 1/2 x 6" Carriage Bolt Hoyse 6nnd: Fasten with SCALE: 3/4"-1 '-0 3/8" x 5" lag screw Support Columns spaced4 16" o.c. and (3) 16d nails 7'.o.c. typical. (U.N.O.) per 16" space. Secure column to ftg. with drift pin or Note: ►„ See plan tot specific details post anchor or special loading conditions. •A•� r `}, •O r . Footing (min. 2500 psi . ' 2 0 ;,T-48 concrete) . . • ' O � r 0 TYP . DECK AND RAIL DETAIL 14 112' Scale, 3/4'-1'-0' r ZZ5,00 1 4-1 41 , lI • i f is J�;,•t','�'y ' tv LOT F , 4 57,078 s . I ;I •� \ ICL • t II �,' a Q r i C14RISTIAIV Rz or oc. I • I �. Q ,W ~AS#""~ sir,AVWX& wr.v AN yw sA-.iv. , , -ma PA"rir A#" c7cw�o�t.M p ,8 NORTAI �1N[�VE 1z M.45 5, "rSN 1�'T Or NG, ANVOW7P �p�4" AWOMAl1�fW l 41STE'Rll7 J AriA��ia ,` �aMgl J .!�/Lwt L.w1G�" � .�,�.. E v ( dPwWAeA/ FO.0 t �zsuo ALFREO OhWr GRSKIIV E8, 3 /Mrr MARCH, /q9/ .wE.�.tawu't'.wc.r�E.wwr,it ,rr,�nr: N9 ~.vww v.•vr,w,• .� ArAw rimwv I-~ d, �� .evnxvt. �.✓oor�.t .�.rs.�c. �rnr A�ihtO M-zsi9 . A•ro, LsJ1.4Z T i . CO -*;p-C-Mea 666! ipoom9- sem �8 -,1_-c��i �y „1� - fGoom w4MMUS ! 09 °!1 si it Z (Ea)+,g S i ti fz) (f i SWV,39 VA' r * m,yyo }` .`.t�v � ..-t,� •i+„ r ,s r�,�.�,w.�.. ti`s �.-�t� --7 t �• a" 44-914911, mm r t s fl� LS 9; 99 4S SS a is 09 a 9P L! w 9► (w Be a a w x m t£ a w a a N w K a u iZ 9 5 tr c z � SOME I4PROVE4EJ -ONT Req 15 is OP 71 YPe PRIVATE TORPOR _CN u[-^� -- -:- ,'.� X E H 711711.v ADMINISTRATOR ^ • 2 81993 OFFICES OF: TOw .Of 120 Main Streek North Andover. APPEALS ;i .y; NORTH ANDOVER Massachusetts 01, BUILDING t+.::��r (617)685.4775 CONSERVATION � 4 DIVISION OF , HEALTH PLANNINGPLANNING & COMMUNITY DEVELOPMENT KAREN H.P. NELSON, DIRECTOR In accordance with the provisions of MGL c 40, S 54, a condition of Building Permit Number -q3 b is that the debris resulting from this work shall be disposed of in a properly licensed solid waste disposal facility as defined by MGL c 111, S 150A. The debris will be disposed of in: (Luca on of.Facility) " ighature ofPermit Appli6 �l AN6 2 Pau^ *cjr/ivc-z,(, 7/a ate NOTE: Demolition permit from the Town of North Andover must be obtained for this project through the Office of the Building Inspector. 2 01%3 �oAndover Town of No. 3 3 '0, r.- " � �o 15 L AJ dower, Mass., L ,� 19 2 coc�'c �t AERAT ED '9S N BOARD OF HEALTH Food/Kitchen PERMIT T D Septic System BUILDING INSPECTOR THIS CERTIFIES THAT...., .... .40'. Aar.. I.. ......................................................... Foundation has permission to erect...A...4rek....... buildings on ...4f A0j.j.rII. ••40.•)•• •......••• Rough to be occupied as.....0 AL ..�i... ... ... / .. ............................................... Chimney provided that the person accepting this permit shall in every respect conform to the terms of the application on file in Final this office, and to the provisions of the Codes and By-Laws relating to the Inspection, Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough PERMIT EXPIRES IN 6 MONTHS Final UNLESS CONSTRUCTION STARTS ELECTRICAL INSPECTOR Rough Service .... .... .... ............ .... .... ... .... ... ... B LDING INSPECTOR Final Occupancy Permit Required to Occupy Building GAS INSPECTOR Display in a Conspicuous Place on the Premises — Do Not Remove RoughFinal No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner PLANNING FINAL W/.Z%J CONSERVATION FINAL street No. Smoke Det. QPIAMP /WAT1=R FINAL /I 7 0 DRIVEWAY ENTRY PERMIT • —�atf(Irp Ya posisss a on►rsat — Alassatiar COMMONWEALTH DEPARTMENT OF PUBLIC SAFETY Code it carso for rwoastlas OF ONE ASHBORTON PLACE Of tills//ate.. MASSACHUSETTS BOSTON,MA 02108 EXPIRATION DATE 12 7 CONSTR. SUPERVISOR cAunoM 10/16/1995 EFFECTIVE DATE LIC-N0. FOR PROTECTION AGAINST RESTRICTIONS THEFT, PUT RIGHTTHUMB NONE 08/31/1993 054617 PRINT IN APPROPRIATE BOX ON LICENSE. RUSSELL C HOLMES > z 41 R AND ST z SS 029-44-0277 z LYNN MA 01904 M( INCLU¢ PH m � PHOTO(BLASTING OPR ONLY) FE nn (� a U•`�'0 NOT VALID UNTIL SIGNED BY LICENSEE AND OFFUALLY HEIGHT- STAMPED-OR-SIGNATURE OF THE COMMISSIONER DOB: 10/16/1957 E MUST BE I�a}}���-- CARRIEDTKS DOONTT E�PERSONOF S NRE OF LICENSEE S SIGN NAME IN®ABpf V LINE THE HOLDER WHEN EN- 057 V OTHERS-RIGFIT THUMB FKiINi GALaEDNTHISOC(,1AATION. R Location— l�.':: �t� 1.� //��•, , No. Date oHoRTHeTOWN OF NORTH ANDOVER 3? �,t`eD ,Moo � e C p Certificate of OccupariFji $ +}�� Building rkme Perrri ee $ ��Ss�cwusEth Found n'Fermit FW,' $ Other Perml!"F96 `' $ s Sewer Comec�tion Fee Y� $ Water Conni)i�-tiok Fee TOTAL ` $ Building Inspector L + Div. Public Works PERJitT NO. �f 2 APPLICATION FOR PERMIT TO BUILD — NORTH ANDOVER, MASS. IZAGE 1 MAP K40. LOT NO. 2 RECORD OF OWNERSHIP :DATE BOOK :PAGE ZONE SUB DIV. LOT NO. OCATION f JI PURPOSE OF BUILDING / ER'S NAME 4 V NO. OF STORIES SIZE WNER'S ADDRESS LL'� C�� BASEMENT OR SLAB ARCHITECT'S NAME_J "/ SIZE OF FLOOR TIMBERS IST 2ND 3RD il UILDER'S NAME � q % j 'MJ J( .P/t/til ) SPAN DISTANCE TO NEAREST BUILDING VVV ry DIMENSIONS OF SILLS STANCE FROM STREET POSTS 4--t-TANCE FROM LOT LINES—SIvDE'S/I 1 REAR GIRDERS AREA OF LOT Q�L/�,J �//Sl 1C:rJ FRONTAGE HEIGHT OF FOUNDATION THICKNESS IS BUILDING NEW N i7 I�lJ V_�s SIZE OF FOOTING X IS BUILDING ADDITION MATERIAL OF CHIMNEY IS BUILDING ALTERATION IS BUILDING ON SOLID OR FILLED LAND WILL BUILDING CONFORM TO REQUIREMENTS OF CODE IS BUILDING CONNECTED TO TOWN WATER BOARD OF APPEALS ACTION. IF ANY IS BUILDING CONNECTED TO TOWN SEWER IS BUILDING CONNECTED TO NATURAL GAS LINE INSTRUCTIONS s PROPERTY INFORMATION LAND COST SEE BOTH SIDES EST. BLDG. COST ,/S VV i PAGE 1 FILL OUT SECTIONS 1 - 3 EST. BLDG. COST PER BQJI FT. PAGE 2 FILL OUT SECTIONS 1 - 12 EST. BLDG. COST PER ROOM SEPTIC PERMIT NO. ELECTRIC METEPS MUST BE ON OUTSIDE OF BUILDING 4 APPROVED BY i` ATTACHED GARAGES MUST CONFORM TO STATE FIRE REGULATIONS s PLANS MUST 9E FILED AND APPROVED BY BUILDING INSPECTOR DA�ATUREOF BOARD OF HEALTH SIER OR AUTI-1RIZED AGENT FEE ^ C' / ` -VVNER TEL.# PUNNING BOARD PERMIT GRANTED CONTR.TEL.# 'G is CONTR.LIC.# �- BOARD OF SELECTMEN 4 1 v 1-4� /^� �� BUILDING INSPECTOR v BUILDING RECORD 1 OCCUPANCY 12 SINGLE FAMILY ORIES THIS SECTION MUST SHOW EXACT DIMENSIONS OF LOT AND DISTANCE FROM MULTI. FAMILY_______]_ OFFICES LOT LINES AND EXACT DIMENSIONS OF BUILDINGS. WITH PORCHES. GA- APARTMENTS I RAGES. ETC. SUPERIMPOSED. THIS REPLACES PLOT PLAN. CONSTRUCTION 2 FOUNDATION 8 INTERIOR FINISH CONCRETE d 1 2 13 CONCRETE BL K. PINE _ BRICK OR STONE H RDW —_ —— PIERS PLASTER _ DRY WALL _ UNFIN. 3 BASEMENT 11 AREA FULL FIN. B'M'TAREA _ '/ 1/7 '/ FIN. ATTIC AREA _ NO BMT FIRE PLACES _ HEAD ROOM MODERN KITCHEN 4 WALLS I 9 FLOORS CLAPBOARDS B 1 2 3 ~ DROP SIDING CONCRETE WOOD SHINGLES EARTH ASPHALT SIDING HARDNPJ'D _ ASBESTOS SIDING COMMCN _ • VERT. SIDING ASPH. TILE _ STUCCO ON MASONRY _ STUCCO ON FRAME BRICK N MASONRY ATTIC STIRS. b FLOOR _ BRICK ON FRAME CONC. OR CINDER BLK. STONE ON MASONRY WIRING STONE ON FRAME _ SUPERIOR I� POOR ADEQUATE NONE 5 ROOF 10 PLUMBING A GABLE HIP BATH (3 FIX.) _ GAMBREL _ MANSARD TOILET RM. (2 FIX.) L FLAT SHED WATER CLOSET •s ASPHALT SHINGLES LAVATORY r WOOD SHINGES KITCHEN SINK _ SLATE NO PLUMBING _ TAR & GRAVEL STALL SHOWER _ ROLL ROOFING MODERN FIXTURES _ TILE FLOOR TILE DADO 6 FRAMING 11 HEATING WOOD JOIST PIPELESS FURNACE -- FORCED HOT AIR FURN. TIMBER BMS. &COLS. STEAM STEEL BMS. 3 COLS. HOT W'T'R OR VAPOR WOOD RAFTERS AIR CONDITIONING RADIANT H'T'G UNIT HEATERS 7 NO. OF ROOMS GAS OIL B'M'T2nd _ ELECTRIC 1st 13rd NO HEATING FORM U - LOT RELEASE FORM INSTRUCTIONS: This form is used to verify that all necessary approvals/permits from Boards and Departments having jurisdiction have been obtained. This does not relieve the applicant and/or landowner from compliance with any applicable local or state law, regulations or requirements. ****************Applicant fills out this section***********�*/***** APPLICANT: b(hoe �- o GkAe o Phone `� LOCATION: Assessor's Map Number Parcel Subdivision Lot(s) Street we l5-a&j St. Number ************************Official Use Only************************ ��R�ECOMMENDATIONS OF TOWN AGENTS: " �i � Date Approved [ )3 Consei7Ation Administrator Date Rejected Comments Date Approved Town Planner Date Rejected Comments Date Approved Food Inspector-Health Date Rejected he-- .2 ,0�%,d-, Date Approved Septic Inspector-Health Date Rejected Comments Iii/ Public Works - sewer/water connections - driveway permit Fire Department Received by Building Inspector Date ZZ5100 +1 Dxolv i 41�* S i. ! LOTS s7 078 -If ; � I � , � i �' 'III i •I'i}�I,� � , i , , �' ' ip ,� I• i ,il , ,1�1'�el, ll' 51 I ! .1• ,I _ 1 it ' �rii,ll � � , ' �S1 I 'w•�I'r 'll Z.,,fO��( .\ • el.,' i :•!,i it 1 I i : .I , ' � i � - '` � .��. (, �i. ?� , �l '111 � `I , . , ' ?�h, i �,�,�,lil�j�� 11 �� a'il I� i • I. i v� �., I ' r. • I i , '� 1, .,i Ilii T1, li + WAY R.Wool I • i I Q 's mr r srll wy m nw r•�srx.wcrcKa� 8 �L OT �L Jb sXlr I�ww'•sews Hint a rsc~+d c r rro a�w �N s ro-a+ar: AWOOC P ��`�sr� � NORTH PIVCOVE/z� MASS, w�►tv s�t•r . rr.vrr. ANcn�� �a'v+�w .ri.+c,.r�s�ar +, AIR�IrAk�rx>K s,. J J uir s.►�cx L� O.e,4,OW t/ AO-r '�'I91►�� �.t�ll Ict,vivf I lky:• 4• I !AM /vtt o ssL �A AL FRED DIA/Jr GAS KlN O Q E461 i (, zl'9 moo. 3 � X"W. Litt! IIC.QN�r 1-Ivor�t .i✓E.�It/k�IGC t".NIW1ffw�rli ,r�1cY't .vww ors�r/e+M r,w,',w11I- GL ^gee A1'JMi/ poly" ^VW~10t. � �vOOrll� .IfI1SriGt�►'yY1'J1 a/V^O /y-Zs/4 •, R•ZIO,pp 1„ ` Location -r S i r-, 'No. r r Date N°"T" TOWN OF NORTH ANDOVER 3?0�,"'° •,Moo " Certificate of Occupancy $ Building/Frame Permit Fee $ S A JACMUS eta F, ndation Permit Fee $ � �OtOr Permit Fee $ r SMAr Connection Fee $ Wafrr Connection Fee $ r- TOT $ — A U I .y r r 7 ' Building Inspector 2 i� Div. Public Works PEbtJfff'NO. 34657D— APPLICATION FOR PERMIT TO BUILD — NORTH ANDOVER MASS. V/ PAGE 1 ` MAP K40. LOT NO. 2 . RECORD OF OWNERSHIP ;DATE BOOK ;PAGE — ZONE I SUB DIV. LOT NO. �— i _-' OCATION F f�; Vh v, , 7 _�� PURPOSE OF BUILDING l/ ��� �� J� fDG1/NER'S NAME ( aAte IA,� -/►L(�/7 NO. OF STORIES SIZE NER'S ADDRESSi-y�eJ/� 1S4F dJ BASEMENT OR SLAB ARCHITECT'S NAME �V W I SIZE OF FLOOR TIMBERS IST 2ND 3RD UILDER'S NAME ami n IlV�.+'1�r /J SPAN DISTANCE TO NEAREST BUILDING` DIMENSIONS OF SILLS DISTANCE FROM STREET POSTS DISTANCE FROM LOT LINES-SIDES REAR GIRDERS i AREA OF LOT FRONTAGE HEIGHT OF FOUNDATION THICKNESS IS BUILDING NEW SIZE OF FOOTING X IS BUILDING ADDITION MATERIAL OF CHIMNEY IS BUILDING ALTERATION IS BUILDING ON SOLID OR FILLED LAND WILL BUILDING CONFORM TO REQUIREMENTS OF CODE IS BUILDING CONNECTED TO TOWN WATER BOARD OF APPEALS ACTION. IF ANY IS BUILDING CONNECTED TO TOWN SEWER IS BUILDING CONNECTED TO NATURAL GAS LINE INSTRUCTIONS 3 PROPERTY INFORMATION LAND COST SEE BOTH SIDES y\�..• ST. BLDG. COST 7 r PAGE I FILL OUT SECTIONS I - 3 71 /� 1 J (J/l J EST. BLDG. COST PER SSQ..J L�1. PAGE 2 FILL OUT SECTIONS 1 - 12 EST. BLDG. COST PER ROOM r SEPTIC PERMIT NO. ELECTRIC METEPS MUST BE ON OUTSIDE OF BUILDING 4 APPROVED BY ATTACHED GARAGES MUST CONFORM TO STATE FIRE REGULATIONS PLANS MUST BE FILED AND APPROVED BY BUILDING INSPECTOR DATE IL D BOARD OF HEALTH SIGNATU E OF OWN€FjOR A TH,ORIZ AGENT FEE R. PERMIT GRANTED OWNER TEL.# �Qf�j/(OS� PLANNING BOARD aCONTR. TEL.# C 43a_L57s' BOARD OF SELECTMEN BUILDING INBPSCTOR 0 BUILDING RECORD 1 OCCUPANCY 12 SINGLE FAMILY STORIES THIS SECTION MUST SHOW EXACT DIMENSIONS OF LOT AND DISTANCE FROM MULTI. FAMILY OFFICES _ LOT LINES AND EXACT DIMENSIONS OF BUILDINGS. WITH PORCHES. GA- APARTMENTS RAGES, ETC. SUPERIMPOSED. THIS REPLACES PLOT PLAN. CONSTRUCTION 2 FOUNDATION 8 INTERIOR FINISH CONCRETE _ 3 1 2 13 CONCRETE BL'K. PINE BRICK OR STONE HARDW D PIERS PLASTER _ _ DRY WALL _ UNFIN. 3 BASEMENT AREA FULL FIN. B M'TAREA _ y, 14 1/ FIN. ATTIC AREA _ NO BMT FIRE PLACES HEAD ROOM MODERN KITCHEN 4 WALLS I 9 FLOORS CLAPBOARDS B 1 2 3 DROP SIDING CONCRETE �_ WOOD SHINGLES EARTH _ ASPHALT SIDING HARDWD _ ASBESTOS SIDING COMMON _ VERT. SIDING ASPH. TILE _ STUCCO ON MASONRY _ STUCCO ON FRAME BRI K N MA NRY ATTIC STRS. & FLOOR _ BRICK ON FRAME CONC. OR CINDER BLK. STONE ON MASONRY WIRING STONE ON FRAME _ SUPERIOR I� POOR ADEQUATE NONE 5 ROOF 10 PLUMBING GABLE I HIP BATH (3 FIX.( GAMBREL MANSARD TOILET RM. (2 FIX.( F FLAT SHED WATER CLOSET _ ASPHALT SHINGLES LAVATORY WOOD SHINGES KITCHEN SINK _ SLATE NO PLUMBING _ TAR & GRAVEL STALL SHOWER _ ROLL ROOFING MODERN FIXTURES _ TILE FLOOR + TILE DADO 6 FRAMING 11 HEATING WOOD JOIST PIPELESS FURNACE FORCED HOT AIR FURN. TIMBER BMS. 6 COLS. STEAM STEEL BMS. 3 COLS. HOT W'T'R OR VAPOR WOOD RAFTERS AIR CONDITIONING RADIANT H'T'G UNIT HEATERS 7 NO. OF ROOMS GAS OIL B'M'T 2nd _ ELECTRIC 1st 13rd NO HEATING OFFICES OF: TOw l-of. `!-:," - . 12o Main Street APPEALS (Q.-I. NORTH ANDOVER - North Andover. BUILDING Massachusetts 01845 CONSERVATION DIVISION OF' (617)685.4775 HEALTH PLANNINGPLANNING & COMMUNITY DEVELOPMENT KAREN H.P.NELSON,DIRECTOR In accordance with t4 provisions of MGL c 40, S 54, a condition of Building Permit Number _ (v 1 is that the debris resulting from this work shall be disposed of in a properly licensed solid waste disposal facility as defined by MGL c 111, S 150A. The debris will be disposed of in: yC4� � "-7 �;r es (Location of.Facility) Si nature of Permit Applicant Ano k (:77 2y ate NOTE: Demolition permit from the Town of North Andover must be obtained for this project through the Office of the Building Inspector. • pRTly Town of And 0 t1% No. %qD N- bq dower, Mass., A _19' 3 COC MiC Hi wic.n V ADRATEDPPS\ BOARD OF HEALTH PERMIT T D Food/Kitchen Septic System O"gkk �� BUILDING INSPECTOR THIS CERTIFIES THAT.........��. ........ ................*... .................pftmko .. .................................... Foundation has permission to swelo...!t$jjN.1j...... buildings on�.� .. 5mw �..... ..... .... ....... Rough OWNto be 0�1 1 .. .. ....4 ..... ...... .. Chimney provided that the person accepting this permit sh in every respect conform to the terms of th application on file in Final this office, and to the provisions of the Codes and By-Laws relating to the Inspection, Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough Final PERMIT EXPIRES IN 6 MONTHS ELECTRICAL INSPECTOR UNLESS CONSTR.UCTI Q AORTS Rough Service BUILDING SPECTOR . Final Occupancy Permit Required to Occupy Building GAS INSPECTOR Display in a Conspicuous Place on the Premises — Do Not Remove RouFinagh No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. _ Burner PLANNING FINAL CONSERVATION FINAL street No. Smoke Det. SEWER/WATER FINAL DRIVEWAY ENTRY PERMIT , „Location n �o• Date J '� N°R'” TOWN OF NORTH ANDOVER � s _ L p Certificate of Occupancy. $, Building/Frame Permit Fee Foundation Pern Fee $ 1�CMU5 a Other Permit Fee C) $ Sewer Connection Pte. $ Water Connectiom Fee $ TOTAL �c9 r t7� t' r Building Inspector v 1 Div. Public Works PER'lfff W. �lO� APPLICATION FOR PERMIT TO BUILD — NORTH ANDOVER, MASS. ✓ PAGE 1 —n: MAP h40. LOT NO. 2 RECORD OF OWNERSHIP IDATE BOOK ;PAGE ZONE SUB DIV. LOT NO. LOCATION �^/,��J �n.`_ PURPOSE OF BUILDING 1 C e Q OWNER'S NAME ���/ fJ b I Qn�— NO. OF STORIES SIZE IF OWNER'S ADDRESS hc BASEMENT OR SLAB ARCHITECT'S NAME SIZE OF FLOOR TIMBERS IST 2ND 3RD BUILDER'S NAME a / SPAN DISTANCE TO NEAREST BUILDING u/Se� DIMENSIONS OF SILLS --_ DISTANCE FROM STREET POSTS DISTANCE FROM LOT LINES-SIDES / Q REAR LSC�, GIRDERS AREA OF LOT A^ y, SCr+G FRONTAGE 7 LJ HEIGHT OF FOUNDATION W THICKNESS IS BUILDING NEW �� t SIZE OF FOOTING 1')-'4 -LN !L X L� IS BUILDING ADDITION Yes MATER:AL OF CHIMNEY ar IS BUILDING ALTERATION l IS BUILDING ON SOLID OR FILLED LAND WILL BUILDING CONFORM TO REQUIREMENTS OF CODE ,�e IS BUILDING CONNECTED TO TOWN WATER BOARD OF APPEALS'ACTION. IF ANY •'a IS BUILDING CONNECTED TO TOWN SEWER IS BUILDING CONNECTED TO NATURAL GAS LINE INSTRUCTIONS 3 PROPERTY INFORMATION LAND COST SEE BOTH SIDES EST. BLDG. COST 4t PAGE 1 FILL OUT SECTIONS 1 - 3 EST. BLDG. COST PER SQ. FT. PAGE 2 FILL OUT SECTIONS 1 - 12 EST. BLDG. COST PER ROOM SEPTIC PERMIT NO. ELESTRIC METERS MUST BE ON OUTSIDE OF BUILDING 4 APPROVED BY ATTACHED GARAGES MUST CONFORM TO STATE FIRE REGULATIONS PLANS MUST BE FILED AND APPROVED BY BUILDING INSPECTOR BOARD OF HEALTH SIGNAT RE OF gWNER OR AUT d IZED AGENT 2 FEE OWNER TEL.$ lvg�—�y(oS� PLANNING BOARD PERMIT GRANTED CONTR.TEL.#I K �-ori f 19 �3 CONTR. LIC. #_III�Q�a-��tC 'r BOARD OF SELECTMEN S? 3 tae I(.I Cvl- (o''_' tr BUILDING INSPECTOR !.J 9 BUILDING RECORD 1 OCCUPANCY 12 SINGLE FAMILY STORIES THIS SECTION MUST SHOW EXACT DIMENSIONS OF LOT AND DISTANCE FROM MULTI. FAMILY OFFICES LOT LINES AND EXACT DIMENSIONS OF BUILDINGS. WITH PORCHES, GA- APARTMENTS I RAGES. ETC. SUPERIMPOSED. THIS REPLACES PLOT PLAN. CONSTRUCTION 2 FOUNDATION 8 INTERIOR FINISH CONCRETE 3 1 2 13 CONCRETE BL K. PINE _ BRICK OR STONE HARDw D — PIERS PLASTER _ DRY WALL _ UNFIN. 3 BASEMENT AREA FULL FIN. B'M'T' AREA _ v, 1/1 '/. FIN. ATTIC AREA _ NO BMT FIRE PLACES _ HEAD ROOM MODERN KITCHEN 4 WALLS I 9 FLOORS CLAPBOARDS B 1 2 3 DROP SIDING CONCRETE WOOD SHINGLES EARTH ASPHALT SIDING HARDW'0 _ ASBESTOS SIDING COMMC:N _ VERT. SIDING ASPH. TILE _ STUCCO ON MASONRY _ STUCCO ON FRAME BRI CK—75—N-M—A30 NRY ATTIC STRS. & FLOOR I_ BRICK ON FRAME CONC. OR CINDER BLK. STONE ON MASONRY WIRING STONE ON FRAME SUPERIOR I� POOR AUATE _ DEQNONE �o 5 ROOF 10 PLUMBING GABLE HIP BATH (3 FIX.) _ GAMBQEL MANSARD TOILET RM. (2 FIX.) FLAT SHED WATER CLOSET _ w ASPHALT SHINGLES LAVATORY _ WOOD SHINGES KITCHEN SINK SLATE NO PLUMBING _ TAR & GRAVEL STALL SHOWER _ ROLL ROOFING MODERN FIXTURES ` TILE FLOOR TILE DADO 6 FRAMING 11 HEATING WOOD JOIST PIPELESS FURNACE FORCED HOT AIR FURN. TIMBER BMS. &COLS. STEAM STEEL BMS. & COLS. HOT W'T'R OR VAPOR WOOD RAFTERS AIR CONDITIONING RADIANT H'T'G UNIT HEATERS ' 7 NO. OF ROOMS GAS OIL B'M'T 2nd _ ELECTRIC 1st 13rd NO HEATING NORTH Town of 4 over d 11% N . Orh A�4 zs 1953 -0C H " dower, Mass., _ / A0RATED PPS' CJ , BOARD OF HEALTH Food/Kitchen PERMIT T D Septic System 6 Aft. BUILDING INSPECTOR THIS CERTIFIES THAT ...... ............A.............................................. *'4.................................... Foundation .. buildings onA). •••• Rough has permission to erect...............���....... ...x_...&VTW- 67=j •� • •••••• to be occupied as:...: � .... �............ ......... ..... Chimney provided that the person accepting this permit shall in every re pact conform to the terms of the application on file in Final this office, and to the provisions of the Codes and By-Laws relating to the Inspection, Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough PERMIT EXPIRES IN 6 MONTHS Final UNLESS CONSTRUCTIO S ARTS ELECTRICAL INSPECTOR Rough V.j ............. ......................................................................... Service BUILDING INSPECTOR Final Occupancy Permit Required to: Occupy Building GAS INSPECTOR Display in a Conspicuous Place on the Premises — Do Not Remove RoughFinal No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner PLANNING FINAL CONSERVATION FINAL street No. Smoke Det. SEWER/WATER FINAL DRIVEWAY ENTRY PERMIT 3'. 4 c 6 7 8 S V 7i 12 13 U S 16 V V V 20 21 22 23 24 25 26 27 28 28 3o m 32 ip W S 37 39 90 aQ dl 412 43 414 415 49 47 08 40 58 Sl 52 43 54 55 56 57 58 1 L7�4TE �! �� Ire _ . . . _ . . _ . . . . . _ . . . . _ . . . _ OFRICE - Joy leo_ �3• �`f • i2 • _ _ _ Job w4YE ' F =� (LcommemFcarimm— ��i Ln M _ E 4 Salo** at U. Ar+s:, Dal. t`:.-{ 1'lrP,. LOOMStd COLLOM tJ �� 1? 1� 1Z �2 12 1Z- i2 iZ )> ja t74 y _ xA 4 x6 Q i _ZY�i: G�K1rT. i :TYh: 1A OD"8.1WS M a� - j — — ,— ' — — — '7tr � - O2x6 ' 2 M 2 x$ M 2xiD 2x12 co 1 � . L' 5 if i i O [g' r, � `r cif'_ a fA t � i� @ 60 Ibs.i sq.8. Fri f6 ED 2=4 2Y8 2 z1D 9y _// _ r' 4 -. .f. 'C.- '} l W j `9 'fid:: 1`� ..`�`�i�l PAG' �.;:N �r I. 2 P'!AS ® � 8 ?G KMG `i 2x6 Lo Lij t-41 3 - RAUJHIGG i 1a1�?� -.slSY. �'i►�{a0 - TYPICAL w Fox CsOPSF -EVE.- LOA.0 :�4 x4 W*od Polis Z _ 2 3t4 Wood Rai o 2 x2 PicloWs STEM _ K 2 x 12 WDodmn Sub"ppm - -- - sua x 6 Ubod Wmads ,x-514 x6 Wood Rio p AINUMMMMi Z Plantegs) [tl - . . . . .y --------- - - - - - - - - - - - vws) - w , ��:�^ su(lat CE _ yexis U �l c� Skkting scows Parch u' ' - i cOUsTxucn DRAFTING OEM �1 �t F_ Office Use Only / L4E CfBmmunWeaf ll Of 4H, u�5 ef�usettn ` Permit No. 7S7 1 1 , d !�trYuIIC2litt tt2 ofuttlit sr'IIt€lii Occupancy 8 Fee Checked r ' 1 3;'40 (leave blank) BOARD OF FIRE PREVENTION REGULATIONS 527 CMR 12:00 APPLICATION .FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code, 527 CMR 12:00 (PLEASE PRINT OFi TxPiE AL� INFr Date /a�_�_ City or own of Dt L. To the Inspector of Wires: The udersigned applies for a permit to rf`orm the electrical work escribed below. Location (Street & Number) Owner or Tenant Owner's Address Is this permit in conjunction wim a building ;.permit: Yes ❑ N 'L—; (Check Appropriate Box; Purpose of Building Utility Authorization No. Existing Service Amps __� Volts Overhead ❑j Undgrnd F-J-1 No. of Meters New Service _ Amps Volts Overhead Undgrnd L..j No. of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work _( �— 5 d UIC d'� ���' No. of Lighting Outlets No. of Hot Tubs No. of Transformers Ttat KVA No. of Lighting Fixtures 111 Swimming Pool AboveF7 In- gmd. grnd. iJ Generators K.,{ I No. of Emergency Ligh:,;ig No. of Receptacle Outlets No. of Oil Burners j Battery Units No. of Switch Outlets I No. of Gas Burners :IRE ALARMS •mo of Zones No. of Ranges No. _ Total No. of Detection and of Air Cond g tons initiating Devices No. of Disposals No.ol Heat Total Total Pumps Tons KW 1 No. of Sounding Devices No. of Salt Contained No. of Dishwashers SpacelArea Heating KW Detection/Sounding Devices No. of Dryers Heating Devices KW Local Municipal Ell Other ry g ❑ Connection No. of No. of Low Voltage No. of Water Heaters KW Signs Bat!asts Wiring No. Hydro Massage Tubs No. of Motors Total HP OTHER: FS 25 j9q7_ INSURANCE COVERAGE: Pursuant to the requirements of Massachusetts general Laws I have a current Liability Insurance Policy including Completed Operations Coverage or its substantial equivalent. YESf have submitted valid proof of same to the Office. YES If you have checked YES, please indicate the type of coverage by checking the a pro n ..box. INSURANCE = BOND u OTHER ._ (Please Specify) {Expiration (Date) Estimated Value of Electrical Work$ Work to Start _. Inspection Date Requested: Rough _ Final Signed under the P nallle of per ury= FIRM NAME �,t� _ LIC. NO- Licensee Licensee +'-'C� /UC—L( Signature .—LIC. NO. Bus. Tel. No. 'r-8 Address n� '.r� �� 1^c''� ✓ ` Aft. Tel. No. OWNER'S INSURANCE WAIVER: i am aware that the Licensee does not have the insurance coverage or its substantial equivalent as re- quired by Massachusetts General Laws, and that my signature on this permit application waives this requirement. Owner Agent (Please check one) Telephone No. 62)_ � f _ PERMIT FEE S `' " 62 ._ tSignature of Owner or Agent) x•6555 i Y Date.. 759 ,i.. .,l.... ' v l` t NpRTh 1 TOWN OF NORTH ANDOVER PERMIT FOR WIRING ,SSACMUSEt This certifies that .......� v\.at&,.Qot.......,- ( �C has permission to perform .........1,N0.. ............................ r.. wiring in the building of.........G �4 Si./1.................................................. ....... ..... . at.... ...... .!9.C1.�.. #� .�.. .`�................ .North Andover,Mass. /f/a.. y Fee..��.,..l�4�... Lic.No. ............ ............... .. ....... .... (( q LECTRICAL P CTOR 15.00 ppID t /03/97 13:112 WHITE:Applicant CA ARY: Building Dept. PINK:Treasurer BUILDING PERMIT l ` TOWN OF NORTH ANDOVER ° o APPLICATION FOR PLAN EXAMINATION Permit NO: Date Received g7lo Date Issued: ��SS Arlo � I PORTANT:A licant must complete all items on this pae LOCATION ChriP af/l 01GAd N D(f� AfAdO0 ! 4,A 0 (8 4- (� Print PROPERTY OWNER HC r 0(-e I NMR Print MAP NQ/ ARCEL: ZONING DISTRICT: Historic District yes rt Machine Shop Village yes n TYPE OF IMPROVEMENT PROPOSED USE Residential Non- Residential ❑ New Building ,®.One family RfAddition ❑ Two or more family ❑ Industrial ❑Alteration No. of units: ❑ Commercial ❑ Repair, replacement ❑Assessory Bldg ❑ Others: ❑ Demolition ❑ Other ❑ Septic -Well ❑ Floodplain L Wetlands E. Watershed District Water/Sewer 0 STA L.L qp F-re AA OU ra' F- SGLAft- A.-,a€LS . I TE nJ N 'r WITt-t U Tl Lr=TY ! ,J e�JS O UJ Identification Please Type or Print Clearly) OWNER: Name: Md a--( (.toil Phone: Address: hrr 0, CONTRACTOR Name: Phone: 1 " t055 &Q(+ Cam Solar SefvioitsDet F=eVotVSvr% Address: Ay• 'J U r (I'n q frilfl MA 0 V�o 5 Supervisor's Construction License: Z Exp. Date: i ZG Flame Improvement License: , c f 3 1 Exp. Date: 3417 7-6 f v ARCH ITECT/ENG I NEERve Civ Eff r1cco"R Phone: O(- q R o- 1775 Address: 3 2 St. wfe ioVSaadWrWolp Reg. No. 71'-0 FEE SCHEDULE.BULDING PERMIT:$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PERS . Total Project Cost: $ 62- 151 . 33 FEE: $ V- Check Check No.: Receipt No.: NOTE: Perso cting with unregistered contractors do not have ess to the guaranty fund _ Vii nature of A ent/Owner Si nature of contractor Plans Submitted ❑ Plans Waived ❑ Certified Plot Plan ❑ Stamped Plans ❑ TYPE OF SEWERAGE DISPOSAL Public Sewer ❑ Tanning/Massage/Body Art ❑ Swimming Pools Well ❑ Tobacco Sales ❑ Food Packaging/Sales Private(septic tank,etc. ❑ Permanent Dumpster on Site ❑ THE FOLLOWING SECTIONS FOR OFFICE USE ONLY INTERDEPARTMENTAL SIGN OFF - U FORM DATE REJECTED DATE APPROVED PLANNING & DEVELOPMENT ❑ ❑ COMENTS CONSERVATION ❑ ❑ COMMENTS DATE REJECTED DATE APPROVED HEALTH ❑ ❑ COMMENTS Zoning Board of Appeals:Variance, Petition No: Zoning Decision/receipt submitted yes Planning Board Decision: Comments a Conservation Decision: Comments Water & Sewer Connection/Signature& Date Driveway Permit Located at 384 Osgood Street FIRE DEPARTMENT -Temp Dumpster on site yes no Located at 124 Main Street Fire Department signature/date COMMENTS Location No. Date • - TOWN OF NORTH ANDOVER Certificate of Occupancy $ Building/Frame Permit Fee $ Foundation Permit Fee $j Other Permit Fee $ TOTAL $ Check# Building Inspector OORTN i F i Town of _ ndover O y.. No. 3- J# C, h , ver, Mass, (O COC.IICMl WIC.f 1. ADRATED S U BOARD OF HEALTH Food/Kitchen PERMIT T D Septic System *IDTHIS CERTIFIES THAT „Pelmkim........., BUILDING INSPECTOR � has permission to erect ........................ buildings on .4�.......C,....r.1..A ''C.0U.....O.�........... Foundation Q .................................. Rough to be occupied as ..... .. . ... ...... . .�. . ..............1. ... .�r. Chimney provided that the person cepting this permit shall in every respect conform to the terms of the application Final on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection,Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR Rough VIOLATION of the Zoning or Building Regulations Voids this Permit. Final �a PERMIT EXPIRES IN 6 MONTHS ELECTRICAL INSPECTOR UNLESS CONSTRUCTION ST Rough Service .......................... ..... ... ........................................ Final BUILDING INSPECTOR GAS INSPECTOR Occupancy Permit Required to Occupy Building Rough Display in a Conspicuous Place on the Premises - Do Not Remove Fin4j No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. Burner Street No. a Smoke Det. UTAH OFFICES ` Sandy ECTOR Layton E n G i n E E R S St. George Project Number: U1883-0028-151 November 18,2015 RevoluSun 1 North Avenue Burlington,MA 01803 ATTENTION: Ryan Stair REFERENCE: Mike Dunn Residence:5 Christian Way,North Andover,MA 01845 Solar Panel Installation Dear Mr.Stair: Per your request, we have reviewed the layout and photos relating to the installation of solar panels at the above- referenced site.The following materials and components are proposed in the installation of the solar panels. Roof Structure:2x8 rafters at 16"O.C. Roof Material:Composition Shingles Based upon our review, it is our conclusion that the installation of solar panels on this existing roof will not adversely affect the structure of this house. The design of solar panel supporting members and connections is by the manufacturer and/or installer. The adopted building code in this jurisdiction is the 2009 International Building Code and ASCE 7-05. Appropriate design parameters which must be used in the design of the supporting members and connections are listed below: Ground snow load:55 psf per Massachusetts amendments to the IBC(verify with local building department) Design wind speed for risk category II structures: 110 mph(3-sec gust) Wind exposure:Category C Our conclusion regarding the adequacy of the existing roof is based on the fact that the additional weight related to the solar panels is less than 3.5 pounds per square foot.In the area of the solar panels,no 20 psf live loads will be present. Regarding snow loads,it is our conclusion that since the panels are slippery and dark,effective snow loads will likely be reduced in the areas of the panels. Solar panels will be flush-mounted,parallel to and no more than 6"above the roof surface. Regarding wind loads,we conclude that any additional forces will be negligible due to the low profile of the flush-mounted panel system. It is our conclusion that any additional seismic loadings related to the addition of these solar panels is negligible. During design and installation,particular attention must be paid to the maximum allowable spacing of attachments and the location of solar panels relative to roof edges. The use of solar panel support span tables provided by the manufacturer is allowed only where the building type, site conditions, and solar panel configuration match the description of the span tables.Attachments to existing roof joist or rafters must be staggered so as not to over load any existing structural member. Waterproofing around the roof penetration is the responsibility of others. All work performed must be in accordance with accepted industry-wide methods and applicable safety standards. Vector Structural Engineering assumes no responsibility for improper installation of the solar panels. Please note a representative of Vector Structural Engineering has not physically observed the roof framing. Our conclusions are based upon the assumption that all structural roof components and other supporting elements are in good condition,free of damage and deterioration,and are sized and spaced such that they can resist standard roof loads. Very truly yours, VECTOR STRUCTURAL ENGINEERING,LLC _10 R ERT. A IVI .a o Roger T.Alworth,S.E. Principal RTA/amw NOV 18, 2015 9138 S. State St., Suite 101 /Sandy, UT 84070/T (801) 990-1775/F (801)990-1776/www.vectorse.com f UTAH OFFICES ` Sandy v ECTOR Layton E n o i n E E R S St. George Project Number: U1883-0028-151 November 18,2015 RevoluSun 1 North Avenue Burlington,MA 01803 ATTENTION: Ryan Stair REFERENCE: Mike Dunn Residence:5 Christian Way,North Andover,MA 01845 Solar Panel Installation Dear Mr.Stair: Per your request, we have reviewed the layout and photos relating to the installation of solar panels at the above- referenced site.The following materials and components are proposed in the installation of the solar panels. Roof Structure:2x8 rafters at 16"O.C. Roof Material:Composition Shingles Based upon our review, it is our conclusion that the installation of solar panels on this existing roof will not adversely affect the structure of this house. The design of solar panel supporting members and connections is by the manufacturer and/or installer. The adopted building code in this jurisdiction is the 2009 International Building Code and ASCE 7-05. Appropriate design parameters which must be used in the design of the supporting members and connections are listed below: Ground snow load:55 psf per Massachusetts amendments to the IBC(verify with local building department) Design wind speed for risk category II structures: 110 mph(3-sec gust) Wind exposure:Category C Our conclusion regarding the adequacy of the existing roof is based on the fact that the additional weight related to the solar panels is less than 3.5 pounds per square foot. In the area of the solar panels,no 20 psf live loads will be present. Regarding snow loads, it is our conclusion that since the panels are slippery and dark,effective snow loads will likely be reduced in the areas of the panels.Solar panels will be flush-mounted,parallel to and no more than 6"above the roof surface. Regarding wind loads,we conclude that any additional forces will be negligible due to the low profile of the flush-mounted panel system. It is our conclusion that any additional seismic loadings related to the addition of these solar panels is negligible. During design and installation,particular attention must be paid to the maximum allowable spacing of attachments and the location of solar panels relative to roof edges. The use of solar panel support span tables provided by the manufacturer is allowed only where the building type, site conditions, and solar panel configuration match the description of the span tables.Attachments to existing roof joist or rafters must be staggered so as not to over load any existing structural member. Waterproofing around the roof penetration is the responsibility of others. All work performed must be in accordance with accepted industry-wide methods and applicable safety standards. Vector Structural Engineering assumes no responsibility for improper installation of the solar panels. Please note a representative of Vector Structural Engineering has not physically observed the roof framing. Our conclusions are based upon the assumption that all structural roof components and other supporting elements are in good condition,free of damage and deterioration,and are sized and spaced such that they can resist standard roof loads. Very truly yours, VECTOR STRUCTURAL ENGINEERING,LLC _�1.JNOF li R ER T. sA IVI Roger T.Alworth,S.E. S/WAL Principal RTA/amw NOV 18, 2015 9138 S. State St., Suite 101 /Sandy, UT 84070/T(801) 990-1775/F (801)990-1776/www.vectorse.com REV,bLU UN. 11, IV,OTHER TERMS AND CONDITIONS A.Access: To enable Contractor to perform its Work hereunder,Client shall grant during daylight hours adequate space on Client's property,as mutually designated by Contractor and Client,for the complete and proper installation,operation,maintenance and repair of the PV System as well as rights of ingress and egress to,through and from such property and the space designated for the PV System. B.Scarcity of Materials:Rights of Termination: The PV System components to be obtained under this Contract are scarce commodities.In order to meet the performance requirements of the PV System described in this Contract,Contractor may substitute the specified brand of solar module or inverter for a similar brand of module or inverter that allows for more timely completion of the installation. Such substitution,if necessary,shall be of UL approved devices,with aggregate performance criteria the same as equipment specified. The governing body for determining performance criteria shall be the CEC (California Energy Commission)that rates all UL approved modules. The key module statistic used for performance criteria will be the DC STC rating of the sum of the modules. The key inverter statistic used for performance criteria will be the AC output of the device. If,due to code requirements,equipment substitution,final engineering,space availability,etc.,the size of a PV System decreases,Contractor shall re- calculate the Contract Price using its standard pricing method and the Contract Price shall be automatically reduced.Client shall be credited by the reduced amount. If due to substitution the DC STC size of the PV System increases slightly,then Client shall not have to pay Contractor similarly. Contractor shall make every reasonable effort to ensure that PV System size does not decrease from the specifications. If the DC STC size of the PV System decreases more than 15%from the Contract's specification amount for any of the reasons stated in this paragraph,Client shall have the right to terminate this Contract within ten(10)days of Contractor's written notification to Client of such decrease,and Contractor shall then refund in full all funds paid to date under this Contract,but shall have no other liability to Client. Contractor reserves the right to unilaterally terminate this Contract within 45 days of its approval without any liability to Client if any of the PV System components required for the completion of Contractor's Work in a timely manner are not available. In the event of such termination,Contractor shall refund all monies paid by Client to Contractor as of the date of termination. C.Limitation of Liability:In no event shall Contractor be liable in an amount exceeding the compensation paid by Client to Contractor under this Contract. Contractor shall not be liable for any incidental,consequential or special damages or for economic loss or expense of for loss or profits or income of Client,or Client's consultants or agents or employees,or any of them,including but not limited to any electricity costs incurred should installation of the PV System be delayed beyond the commencement or completion schedule set forth above. D.Zoning:Client shall pay for all variances,special permits,or other costs related to zoning,including without limitation any fees or costs related to attorneys or engineers. E.Client's Property:Client agrees to remove or to protect any of Client's personal property,inside or out,which may interfere with or obstruct the Work, Including but not limited to landscaping,and Contractor shall not be held responsible for damage to such property. Client understands and acknowledges that proper operation of the PV System purchased hereunder is dependent on Client's existing roof and equipment and Contractor shall have no obligation or liability for the condition thereof,or any other part of Client's improvements or equipment not purchased hereunder. Client expressly represents that the roof of the property upon which the PV System will be installed is in good condition,with no known water infiltration problems or other structural defects. F.Insurance:Client must carry all fire,casualty,hurricane,earthquake,theft,and other insurance related to Client's real and personal property. G.Cancellation of Contract: If Client cancels or breaches this Contract after the opportunity to execute three(3)day rescission has passed but before commencement of construction,Client shall pay Contractor the amount of expenses incurred to that date plus 20%of the Contract Price. If Client fails to pay said amounts within thirty(30)days of Contractor's demand for payment and Contractor files suit,Contractor shall be entitled to recover all of its damages including its loss of net profits and attorneys'fees and costs if Contractor is the prevailing party. H.Costs of Collection: If Client fails to pay any amounts owed to Contractor when due,Client shall be liable for all costs of collection,including reasonable attorneys'fees,plus 18%interest per annum on the unpaid balance. Contractor also shall have option of removing all or part of the PV System from Client's premises in addition to receiving payment equal to the value of the unpaid balance to cover all or a portion of Contractor's consequential damages. I.Liens:Contractor,any subcontractor(s)and any other persons or entities supplying labor and materials to Client under this Contract,have the right under applicable law to impose a lien on Client's real property for the value of the labor or materials provided. Upon Client's payment of all amounts due under this Contract,Contractor will provide,upon Client's request,a release and waiver of any liens. J.Force Majeure:Contractor shall not be liable for any delay In material and/or equipment delivery or for failure to deliver or failure to perform the Work which results from any cause beyond the Contractor's control. Such causes include but shall not be limited to:an act of God or of the public enemy;an act(or failure to act)of any government or utility;a fire,flood or epidemic;quarantine,restriction,strike,freight embargo,terrorism,theft or unusually severe weather;Contractor's inability to obtain necessary materials,labor or transportation;custom permitting caused by Client's site conditions; homeowner association review or approval;building or other code requirements relating to Client's existing electrical system or building characteristics; and any other impediments to the installation of the PV System arising from Client's acts or omissions and/or the condition of Client's property. 3 Northeast Solar i 4 s 1 North Ave Suite A t M� =M Burlington,MA 01803 Revol u S u n.COtTI & 781.240.6555 116298 VA6.02 1012112076 REVOLU, SUNO K.Legal Compliance and Severability:Contractor and Client acknowledge that the form,substance,content and notices contained in this Contract are intended to comply with Chapter 142A of the Massachusetts General Laws,and regulations promulgated thereunder. In the event of any instance of non- compliance,only such portion shall be invalid and the remainder of this Contract shall be in full force and effect. In addition,any such portion not in compliance shall be read and interpreted so as to have its intended meaning to the maximum extent allowed under such law and applicable regulations. L.Entire Contract•No Waiver Unless In Writina:This Contract constitutes the entire contract between the parties;there is no representation,warranty, collateral contract or condition affecting this Contract except as expressed in it. No provisions of this Contract shall be changed or modified,nor shall this Contract be discharged or waived,in whole or part,except in writing signed by both parties.This Contract shall not be effective until fully executed by Client and an Authorized Representative of Contractor. M.Client's Representation of Authority:If this Contract is signed by less than all of the persons or entities who own the subject property,then Client who signs this Contract(or any of the provisions hereof)represents to Contractor that he,she or it has full legal authority to bind the other persons and/or entities. N.Governing Law:The laws of the Commonwealth of Massachusetts shall govern any proceeding or dispute related to this Contract. Client: Contractor: Michael Dunn Name: GW _ Date: /p OU-�� Title: Date: !G 4 Northeast Solar 1 North Ave Suite A Burlington,MA 01803 i .._.,$:,.._. RevoluSun,com 781.240.6555 116298 Vv,.5.02 1012112015 R EVC LU U NT III.IMPORTANT NOTICES A.Contractor's Registration: All home improvement contractors and subcontractors engaged in home improvement contracting,unless specifically exempt from registration by provisions of Chapter 142A of the Massachusetts General Laws,must be registered with the Commonwealth of Massachusetts. Inquiries about registration and status should be made to the Director of the following state agency: Office of Consumer Affairs and Business Regulation Home Improvement Contractor Registration Ten Park Plaza,Room 5170 Boston,MA 02116 (617)973-8700 B.Client's Cancellation Rights: Client may cancel this Contract,without penalty or obligation,within three business days following the date on which Client signs this Contract. A Notice of Cancellation is attached hereto for Client's convenience. C.Warranties:For a period of ten(10)years from Substantial Completion,Contractor warrants that the PV System has been designed and installed in a good,workmanlike and substantial manner in accordance with all applicable building codes. In the event Contractor is required to penetrate the roof of the Client's property in the course of installation,and causes damage to the roof within a three (3)radius of a penetration,Contractor will repair such roof damage for a period of five(5)years from Substantial Completion or the remaining term of the roofs existing installation warranty,whichever is shorter,to prevent any water,rain or other moisture leak,seepage or entry directly caused by such penetration.These warranties are for normal use and conditions only.All warranty coverage to equipment and workmanship installed by Contractor will be VOID if any alterations or repairs are performed by any person or persons not expressly authorized,in writing,by Contractor.WTHIS WARRANTY DOES NOT COVER:(a)Damage caused by external forces such as,but not limited to,vandalism,theft,terrorism,fire or act of God;(b)Damage caused by weather effects exceeding manufacturer tolerances;(c)Normal wear and tear or aging of a PV System;(d)Any implied warranties:(e)Electric bills,water damages or any other consequential damages;or(f)Damage to the PV System or its efficiency due to adjustment,moving,or tampering with the PV System or any of its components by individuals not approved by Contractor. D.Change Orders: Any alteration or deviation from above specifications involving extra costs must be subject to a written change order signed by both parties,which shall be incorporated into this Contract,and Client shall be liable for any additional costs resulting from each change order. By initialing the space below,Client hereby specifically agrees to execute a change order,and pay the additional costs,if it becomes necessary for Contractor to repair or replace un-approved or non-code compliant electrical work in order to complete the PV System installation and satisfy code requirements. Client's Initials: aid Client's Initials: ARBITRATION: CONTRACTOR AND CLIENT HEREBY MUTUALLY AGREE IN ADVANCE THAT IN THE EVENT CONTRACTOR HAS A DISPUTE CONCERNING THIS CONTRACT,THE CONTRACTOR MAY SUBMIT SUCH DISPUTE TO A PRIVATE ARBITRATION SERVICE WHICH HAS BEEN APPROVED BY THE DIRECTOR OF THE EXECUTIVE OFFICE OF CONSUMER AFFAIRS AND BUSINESS REGULATIONS AND CLIENT SHALL BE REQUIRED T9 SUBMIT TOS H ARBITRATION AS PROVIDED IN M.G.L.c.142A. Client: Date: 16 v9214'�— Client: Date: Contractor Date: NOTICE: The signatures of the parties above apply only to the agreement of the parties to alternate dispute resolution initiated by Contractor. Client may initiate alternate dispute resolution even where this section is not separately signed by the parties. E.Incentive Guarantee: By Client's initials below,Client acknowledges and agrees that Contractor has not and does not guarantee Client's qualification for,receipt of or amount of any tax credit,rebate,solar renewable energy credit(SREC)or other incentive amount in connection with the PV System,and any estimates of incentives(wither in a PV System proposal or otherwise)are not guaranteed to be accurate or available. Client is responsible for determining Client's and/or the PV System's eligibility for any incentives and should consult with tax,legal and other advisors regarding availability and possible tax consequencesofclaiming the same. Client's Initials: �L Client's Initials: r.t , 2 Northeast Solar j 5 Er t 1 North Ave Suite A Burlington,MA 01803 R evol u S u n.com 781.240.6555 116298 VV1.5.02 10121/2015 REVOLU . UN. THIS HOME IMPROVEMENT SOLAR ENERGY CONTRACT(this"Contract")IS BETWEEN:Michael Dunn("Client")located at 5 Christian Way North Andover,MA 01845("Client's Property") -AND- Northeast Solar Services,Inc.®("Contractor")of 1 North Ave Suite A Burlington,MA 01803,with Home Improvement Contractor Reg.No.178137,which expires on March 17,2016,and Federal Employer ID 46 0569853.Contractors sales person for this contract is John Ferullo. The parties to this Agreement agree as follows: I.SCOPE OF WORK A.Installation of PV Sy is em.The above Client(s)has engaged Contractor to perform the following residential contracting work(the"Work")in connection with the installation of the following photovoltaic solar energy system(the"PV System"): 31 Sun Power-SunPower 327 waft modules(or equivalent) with 1 Solar Edge-Solar Edge SE 10000 inverters(or equivalent)and all mounting, disconnects,and all other PV System components necessary for a National Electric Code compliant PV System,totaling 10.137kW,located at Client's Property. B.Other Inclusions The Work shall further include: •Installation of the PV System in accordance with all State of Massachusetts interconnection standards. •All reasonable engineering and permitting costs. •The following building permits are required and will be secured by Contractor as Client's agent:Building and Electrical Permit. •Following the installation,Client will receive a PV System orientation and a PV System Client's manual. Notice: It shall be the obligation of the Contractor to obtain all permits related to the Work. Clients who secure their own permits will be excluded from the guaranty fund provisions of Chapter 142A of the Massachusetts General Laws. 11,COMPENSATION AND SCHEDULE A.Contract Price For Contractor's performance of the Work under this Contract,Client will pay Contractor a total of: $48,967.29(FORTY EIGHT THOUSAND NINE HUNDRED SIXTY SEVEN AND 29/100)DOLLARS USD(the"Contract Price"). B.Payment Schedule The Contract Price will be payable in accordance with the following payment schedule: Date Paid: $24.483.64 Initial Payment-50% (Due upon Contract signing,which is an amount less than the cost of the materials and equipment which must be specially ordered in advance of commencement of PV System installation) $22.035.28 Progress Payment-45% (Due upon Substantial Completion) $2.448.37 Final Payment-5% (Due upon Final Completion) C.Schedule The"Start Date"of this Contract is the date Contractor receives the full amount of Client's initial payment of 50%of the Contract Price. Subject to adjustment for any Force Majeure reason stated in Section IVA.,the Work is estimated to begin within 12-16 weeks from the Start Date of this Contract.The parties agree that this date shall be automatically extended to the date of delivery of all materials and equipment which mut be specially ordered. Substantia!Com tD etion is estimated to occur within 16-20 weeks from the Start Date of this Contract,but the parties agree that this date shall be automatically shortened or extended to the date on which all racking and electrical work are complete and the PV System is capable of generating power and ready and available for use subject to final government and utility approval. Finat Comntetion Is defined as the date on which all punch list Items are complete,all permits are closed,all other government and utility approvals are obtained and the Work is complete to the satisfaction of Contractor and Client. Client acknowledges and agrees that the Work involves permits,inspections and approvals from various government agencies and utilities,and therefore the timing of the Work may vary and is not within Contractors control. Client further agrees that Contractor shall not be liable for any losses, costs or damages related to any delays for reasons beyond Contractors control,including all causes noted in the Force Majeure section of this Contract below. 1 Northeast Solar 1 North Ave Suite A s { Burlington,MA 01803 ' RevoluSunxom '` 781.240.6555 116298 Vv1.5.02 1021/2015 PROJECT DESCRIPTION Cont—tor: f THIS ROOF MOUNTED PHOTOVOLTAIC (PV) SYSTEM IS TO BE INSTALLED AT THE SINGLE-FAMILY DWELLING IN NORTH ANDOVER, MASSACHUSETTS. REVOLUUM THE ENERGY PRODUCED BY THE PV SYSTEM SHALL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ON-SITE ELECTRICAL EQUIPMENT VIA A SUPPLY SIDE CONNECTION IN THE MAIN SERVICE PANEL. THIS PROJECT DOES NOT INCLUDE STORAGE BATTERIES. I NORTH AVENUE BURLINGTON,MA 01803 SHEET INDEX SCOPE OF WORK CONSTRUCTION NOTES P:(781)270-6555 T 1.0 COVER (33)PV MODULES(TOTAL: 580 5Q. FT.) 1.)CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO wWW.H19592LhU9Ctt5.l tVdUSU.COm A1.0 SITE PLAN (1) 10.0 kW INVERTER INITIATING CONSTRUCTION. A I.I ROOF: PV LAYOUTS (33)SOLAREDGE POWER OPTIMIZERS 2.)CONTRACTOR SHALL REVIEW ALL MANUFACTURER INSTALLATION DOCUMENTS PRIOR TO INITIATING CONSTRUCTION. A2.0 MOUNTING t-RACKING METHOD (74)ATTACHMENT POINTS @ 48"O.C. MAX. 3.)ALL EQUIPMENT SHALL BE LISTED BY U.L.(OR EQUAL)AND LISTED FOR E 1.0 ELECTRICAL DIAGRAM (1)AC DISCONNECT, 240 VAC, NEMA 3R ITS SPECIFIC APPLICATION. 4.)ALL EQUIPMENT SHALL BE RATED FOR THE ENVIRONMENT IN WHICH IT ENORTH E2.0 SAFETY PLACARDS (1) LOAD CENTER, 240 VAC, NEMA 3R I5 INSTALLED. E51DENCE DI.O PV MODULE DATA SHEET (1)PV METER, 240 VAC, NEMA 3R 5.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THETIAN WAY MANUFACTURER'S INSTALLATION INSTRUCTIONS. VER,MA01845 D2.0 PV INVERTER DATA SHEET 02_1 G-0024 G.)ACCESS TO ELECTRICAL COMPONENTS OVER 150 VOLTS TO GROUND D3.0 50LAREDGE OPTIMZER DATA SHEET SHALL BE RESTRICTED TO QUALIFIED PERSONNEL. Protect Details: 7.)ALL CONDUCTORS SHALL BE COPPER,RATED FOR GOO VOLTS AND 10.791 kWstc, 10.00 kW AC SITE SPECIFICATIONS 90°C WET ENVIRONMENT,UNLESS OTHERWISE NOTED. PARTS LIST OCCUPANCY CATEGORY: II 8.)WHERE SIZES OF JUNCTION BOXES,RACEWAYS,AND CONDUITS ARE NOT SPECIFIED,CONTRACTOR SHALL SIZE THEM ACCORDING TO EngIneenng Approval: Quantity De5crlptlon DESIGN WIND SPEED: 100 MPH APPLICABLE CODES. EXPOSURE CATEGORY: 5 9.)PV MODULE FRAMES SHALL BE BONDED TO RACKING RAIL OR BARE 33 5olarEdge P400 GROUND SNOW LOAD: 50 P51' COPPER G.E.C.PER THE MODULE MANUFACTURER'S LISTED INSTRUCTION SHEET. 45 PV Module 10.)PV MODULE RACKING RAIL SHALL BE BONDED TO BARE COPPER 74 QMPV Classic Comp Flashing G.E.C.VIA WEEB LUG,IL5C0 GBL-4DBT LAY-IN LUG,OR EQUIVLENT LISTEDLUG. 74 Unirac L-Foot GOVERNING CODES 1 1.)GROUNDING ELECTRODE CONDUCTOR(G.E.C.)SHALL BE CONTINUOUS 2014 NATIONAL ELECTRICAL CODE AND/OR IRREVERSIBLY SPLICED/WELDED. 74,5/1 G"Lag Screw 780 CMR,8th EDITION 12.)ALL JUNCTION BOXES,COMBINER BOXES,AND DISCONNECTS SHALL BE INSTALLED IN AN ACCE551BLE LOCATION. 246 Feet of Unirac SunFrame Rad UNDERWRITERS LABORATORIES(UL)STANDARDS 13.)ROOF ACCE55 POINTS SHALL BE AT A STRONG POINT ON THE OSHA 29 CFR 19 1 0.209 BUILDING AND NOT REQUIRE THE PLACEMENT OF LADDER5 OVER EXTERIOR REVISIONS WALL OPENINGS. DE5CRIPPON DATE REV 14.)WORKING SPACE AROUND ELECTRIAL EQUIPMENT SHALL COMPLY WITH ORIGINAL 1121/20IG A NEC 110.26 EQUIP RELOCATE /20201G B yy LOUIPRELOCATE II 1/27/20IG C 13 13 IN _r,.„• �hcct Title: COVER hect Number: TI .0 • �� • •t Sheet 5¢e: ANSI B - 17"x I I" K s . �'�• E51GN F DRAFTING BY: /I/ w ,y, `�� ,'^.,+ �� • JOEL HORST � >• AYE • �' Ch10 PARCEL MAP Ll AERIAL MAP �� VICINITY MAP �� Rev,ewed k Approved by: PROJECT LOCATION J EH j� Contractor: tJ 200'TO CHP15TIAN WAY REVOLU(SUN a.erer.emvLar.ewer. I NORTH AVENUE BURLINGTON,MA 01803 P:(781)270-6555 215° www.Ma5wchu5dt5.Revolu5un.com Protect: DUNN PF51DENCE 5 CHRISTIAN WAY NORTH ANDOVER,MAO 1 845 JOB#:MA02 I G-0024 I---_ 70'-9" Protect Details: h 10.791 kWstc, 10.00 kW AG 3/4"EMT THROUGH ATTIC UTILITY METER DOWN CHASE TO BASEMENT En meerm MAIN SERVICE PANEL g g A pproval: AC DISCONNECT I I PV METER INVERTER W/DC DISCONNECT PV LOAD CENTER REVISIONS Dt5CKMON oATE REV URIGINAL 1/21/2016 A DRIVEWAY a a ——— — 48'-411 EQUIP RELOCATE I 1/2G2016 e PV ARRAY EQUIP RELOCATEIt Ii27i201e c OPTIMIZERS UNDER PV MODULES JUNCTION BOX 3G°PITCH TYP. Sheet T1tle: SITE PLAN Sheet N—ber: A I .O 51111 51ze: ANSI B — 17"x I I" DESIGN 6 DRAFTING 8Y: /) JOEL HORST G ft 12 ft 24 ft Reviewed 6 Approved by:_ SCALE: I"= 12- EH 15'-3" Contractor: RIDGE 4'MAX. 1.-4"TYF. ! I I I 1, I 1 I I 11 11 REVOLUCSI.UN I NORTH AVENUE ! I I ! ! ! I�' 2" ( I ! ! ! ! BURLINGTON,MAO 1803 ! - ( I P:(781)270-6555 11 I I! i! U I! II n v II II I! II Ii www.Ma5wehuwtt5.Revok5u.com -11 II II -trII II 11 I II p II II II I II p 11 =AY 24'-O411 11 ! CE I II 11 11 !! 11 III I ! �'-611 ITH 0024MAO 45 ! 11 II 11 II I II II it II II 11 11 II II II 11 II I II II !1 11 11 Project Detad, �I r II LT, 1 I! I! T I! I! T I! 1! �T i I! II T I II I Ili II 11 I jl 0.79I kWstc, 10.00 kW AC !! �I I it Il 11 11 I it 11 it II 11 I�„ 11 it II 11 11 I 11 II II 11 i II !1 II 1 I I 1 ! 1 I ! I IT—IT3O 4 1 i I I I I I II ! Engineering App—l: ! 1 II II 1! 11 II II 11 II 11 II II 11 ii II II II 1 11 II I1 11 I 11 11 II II 11 1 II II II it ! 11 11 p 11 11 3G°�FIT.CH it ii it II p ! II 11 11 11 I II !! 11 II II 11 II II I i ! L i! II L i! Il MAIN ROOT= SAVE II II I! !! ! " II II i! I! D I! I! I! ! II ! SCALE: I"=4' — - — — 1 — — - _{� —"� '� 441.41 _1 2 ft 4 ft 8 ft LEGEND � FLASFIING PAFTEP/TRU55 PV MODULE 23'-5" L 7 REVISIONS 14 TYP. 1 1 DESCRIPTION DATE REV 4 MAX ORIGINAL 1/21/2016 A _ j F__ —n RIDGE 1J 215" EQUIP RELOCATE 1/26/2016 D I ! I I 71 -17— EQUIP RELOCATE It 1/27/2016 C it Ii II i II it 11 I p II 11 11 p 11 11 11 11 I i I i 15'-4 1 I I i I I 11 Q 11 II ii 11 Ii Ii U i 11 411 I 11 II 11 11 Q II 11 11 p F IT i 11 ' T l I I! T i I! ! FIT',i 11 IT, 11 II 11 11 11 11 II II !! I! II I! h-t Title: ROOF Ii Il Ii I! I! I! Il ! Il I! II II Ii I! II I! II PV LAYOUTS 1 ( ! 1 ! ! I 1 I! II I! !! I! I! 14'G" Sheet Number: IT -iT 11 j1 -IT 11 11 11 11 -1T 11 11 11 II 11 11 A I . I Il !! I! I! I! Il !! ! I! I! II I! I! !! II !! I! Sheet 51ze: I! II II 11 11 11 II I 11 II p II I! I! I! I! I! ANSI B - 17"x I I" 41 I! II 11 11 11 11 DE51GN 6 DRAFTING BY: /) II II 11 II I I II 11 I !! 11 11 11 11 11 II 11 11 JOEL HORST 3GD°�PlTcrl T I! I T i 11 I! ITi I! ! 1 T I! ITi 11 11 1111 11 11 ie L SEPI GARAGE ROOF F71 I—2 ft+—4 ft 8 ft SAVE Reviewed d Approved by: SCALE: I"=4' EN i t I I I I I I I I I I i t I I Contractor: II II II II II II 11 II I I I I I I I I I I t l I I I I REVOLU(SUN I I I I I r--I—I--- I I I I r--I—I--- I I Gasnec.Tarter solar. . RAFTER'L 1' I-4"T.p�i I i i 1 1 I ( I I i I I i I I BURLINGOTON.MA 0 803 PV MODULE RTH AVENUE 1f 11 I I 11 11 I I P:(781)270-6555 -- — -- — — www.Miswchu5ctts.Revoki5un.com II II ` II it II II II i I G.MAY. I-4'MAX I I I I I I I i II II II II II II II i II II II II II II II I I I I I I I I I I I I I I I I Pr,ect: I I I I I I I I I I I I I I I DUNN RESIDENCE I I I I I I I I I I I I I I I 5 CHR15TIAN WAY I I I I I I I I I I I NOJOB NNMAA02R 45 1 6 0024 I I I I I I I I I I I I I I Project Details: II II II II II II II I I I I I I I I I I I I I I I I 10.791 kWstc, 10.00 kW AC II II II II II II II I STRUCTURAL CALCULATIONS I I I I I I I I I I I I I I I Engmee—,j Approval: QTY WEIGHT EA. TOTAL I I I I I I I I I I I I I I I II II II II II II II I PV MODULE 33 x 41.0 LBS = 1 353 LBS FLA51-1IN I I I I I I I I I I I I I I I RACKING RAIL 246 x 0.75 LB/FT = 185 LBS L-FOOT ATTACHMENT 74 x 4.0 LB5 = 296 LBS I I I I I I I I I I I I 1 1 I RACKING RAIL TOTAL WEIGHT: 1834 LBS I I I I I I I I I I I I I I ARRAY AREA: 579 5Q. FT. DEAD LOAD: 3.2 P5F POINT LOAD: 24.8 LBS I I I I I I I I I I I I I I I I I I I I I I REVISIONS f—bin 16 inQE5CLrloN Dare REv MOUNTING PLAN VIEW �� ORIGINAL 1126/2017 A SCALE: "= I G" .� EQUIP RELOCATE 1/27/201 G H EQUIP RELOCATE II I/27/2016 C 3 \ 1\ UNIRAC CAP STRIP UNIRAC SUNFRAME RAIL 6 . PV MODUIJ: Sheet Title: UNIRAC L FOOT MOUNTING \ PvQUICKME)i RACKING METHOD ----- CLA551C COMP Mg1NT Sheet Number: k A2.0 OQF - COMP05TTION ALUMINUM FLP5HING p5\S10N / ROOF sheet SI:e: '00? oG ANSI B - 17"x I I" \6 5/16'55 LAG SCREW DE51GN R DRAFTING I _ MIN 2-1/2'THREAD PENETRATION JOEL HORST SID 5EALED W/CHEMUNK M 1(OR EQUIVJ' v - - MOUNTING METHOD �� —'�� �' MOUNTING DETAIL _ - SCALE: I"= 12" .- ,;.-�'-� _ SCALE: I"=G" _ - 6 in��1 2 1n -- 24 m— — -_ ppr - n 6 in---�—1 2 m�_( Reviewed b A oved by: --EQUIP.GROUNDING CONDUCTOR -=CIRCUIT CONDUCTOR 'V, -FU5E CIRCUIT BREAKER (N)-NEW EQUIP. (E)-EXISTING EQUIP. L I -UNE I(BLACK) L2 -UNE 2(UD) N❑-NEUTRAL(,k411TE) G❑-GROUND(GREEN) -P051TIVE(RED) E-NEGATIVE(BIACK7 Contractor: Array Configuration PVModuleSpecifications Inverter Specifications Power Optimizer Specifications ACSystemSummary L�� System:10.791 kWstc,10 kW AC Model Number: SUNPOWERE20-327 Model Number:Solar EdgeSE10000A-US Model Number: SolarEd eP400 NOMINAL SYSTEM VOLTAGE: 240 Volts AC REVOLU(SUN Total PV Module Qty:33 Weight: 41.0 lbs Power Rating: 10.00 kW AC Max Input Power: 400 Watts MAX CURRENT PER 690.8(A): 42 Amps Inverter l.D.# Inv 111 Dimensions: 61.39 X 41.18 x 1.81 (in) Nominal Voltage: 240 Volts AC Max Voc: 80 Volts DC MAX CURRENT PER 690.8(8): 53 Amps I NORTH AVENUE Module Power @ STC: 327 Watts Max Output Current: 42.0 Amps Max Isc: 10.1 Amps DC BURLINGTON, 0 1803 Inverter AC Power(kW): 10.00 P:(781)270-G555 PV Power(kWstc): 10.79 Voc(open-circuit Voltage): 65 Volts DC CEC Weighted Efficiency:97.5% Output Current: 15 Amps www.Ma5sadusetts.Revolusun.com Module Total Qty: 33 Vmp(max-power Voltage): 54.7 Volts DC Maximum DC Voltage: 500 Output Voltage: 60 Volts DC Inverter DC:AC Ratio 1.08 Isc(short-circuit current): 6.5 Amps Inverter Quantity: 1 Min.String Length: 8 String Qty: 2 Imp(max-power current): 5.98 Amps Max.String Length: 25 Q String Length: 12 Mfr Voc Temp Coefficient: -0.27 %/`C Max.String Power: 5,250 Watts Max Open Circuit Voltage 500 Pr acct: DUNN RE5IDENCE 0• Operating Voltage: 350 5 01R15TIAN WAY Z NORTH ANDOVER,MAO 1845 Max Short Circuit Current 28.0 JOB#;MA02_I G-0024 Operating Current: 22.4 Protect Details: Stri ng Qty. 1 10.791 kWstc, 10.00 kW AC m String Length: 9 I- Max Open Circuit Voltage 500 d Englneering Approval: Operating Voltage: 350 TO UTILITY GRID Z Ma x Short Ci rcu it Curre nt 10.5 Operating Current: 8.4 ( O Unu,.!T0,RONAL i(N)AC D15CONNECT PnASE,240 v IPnrzex I (N)PV LOAD CENTER (N)PV ER MET129 - �x ROOrTDP I IN BASEMrN_ 1-5L T1 zG I r w -- rover oP n+rERcourrernon D 10 IG (N7 LINE oe TAP MwUm slI(N)INVERTER(QTY 1) I 55A r0 I ER NEC 240.21(B)(I)4 705.12(10 _IAC Ir LENGTH Of TAP CONDUCTOR5 W01_11� 1 BOX IOa I 51AU NOT EXCEED IO IT UN-P... O. , 200 A SERVICE 015CONNECT u 55A E L_ _ I 200 A.240 V.2-P REV15I0N5 DxD�xrR- P4Ax.�.4MNN ' xollmxD nrnrcR I -' DE5CPJPTIOH DATE REV • • • • E)BUS BnRS:200 AORIGINAL 1/21/2016 A 2 12 I 2 2EQUIP RELOCATE I 1/26/2016 B _ EQUIP RELOCATE II 1/27/2016 C (E)Maw seevlcE PANELSTRING I:(I)PV MODULE PER OPTIMIZER 5TRING 2:(1)N MODULE PER OPTIMIZER STRING 3:I I)PV MODL_- --- (12)OPTIMI2ER5 CONNECTED IN 5ERLr (12)OPTIMIZERS CONNECTED IN SERIES (9)OPTIMIZER5 CONNECTED IN SERIES DC3 3.924-TOTAL 3.924 kWstc TOTAL 2.943 k-TOTAL _--pN ROOFTOPI IN BASEMENT_ 1(E)GROUNDING 'ELECTRODE SYSTEM � heet Tltle: WIRE AND CONDUIT 5CHEOULE ELECTRICAL GOND COND GOND GND GNI) GND CONDUIT CONDUIT E5T. DIAGRAM PV System Maximum Voltage Calculation per NEC 690.7(A) TAG OTY 51ZF TYPE QTY SIZE TYPE 51ZE TYPE D15T. Sheet Number: Voc Temp Local Record Low Temp: -18°C Data Source: LAWRENCE MUNI E I •O Coefficient x 25°C- Voc Voc Number of Termperature DC I 2/5TRING AWG#1 0 PV-WIRE I AWG#G BARE CU N/A WA 10 Sheet 512e: Record +1 = Correction Correction x Voc x Modules in = Corrected Open DC2 2 AWG#8 Tt1WN-2 I AWG#I 0 TtiWN-2 3/4" EMT 50 Low Temp. Factor Factor Series Ci rcu1t Vol to ge DC3 2 AWG#10 THWN-2 ANSI 5 - 1711 X I III 0.27%/°C X 43°C +1 = 1.116 1 1.116 X 64.9 X 1 = 72.4 VOIYS DC AC 1 3 AWG#G TI1WN-2 I AWG#8 TI-IWN-2 3/4" EMT 50 DESIGN C DRAFTING BY: H+�- CONDUCTOR SPECIFICATIDNS REQUIRED CONDUCTOR AMPACITY AMPACITY CHECKEI CONDUCTORTEMPERATUREDERATING CONDUITFILLDERATING CORRECTEDAMPACITYCALCUTATION AMPACITYCHECKk2 VOLTAGEDROP JOEL NOR5T CIRC4N. C.-.NC CIRUIT TAG _ iY® DUROP T TING TfMP VOLTAGE "RATD UT ORIGESTINATION TERI = x = G PAOn ♦�" xMFxT Mv'YN MPI'0 3 DC] PVSTNCOPPER p90'CG AWG p10330m Amts 150001 Tp11xc5 - 15pOxNn 0125 = 1B80ampz i8.8P0an <d0.0AMos ROOROP Fp EG32 ooi In D.tSZa 3 TE 01500'63 a OUNUAROp mx1.000x °M� x DOp]6E x 01000=E30.d0 G1s.D4AmP•<3Dd Amps 01101�� 0.11% DOE COMNNINVE0.TER x COPPER JS'C AWGMB 50 Ams 15.00 0 2 • 30.0 am L25 = 3J.5 amps 3J.5 am <50.0 M 1x0000.5 b•AIR 32 N/A < 32 I 0.94 d I 0.80 a 50 x 0.90 x 0.80 - 32.6 30.0 Am <37.6 Amps SOO 0.71%DC3 COMRINCOPPER JS'C AWG K30 3s Am S 15.00 x 1 = L5.0 amps x L25 = SK8 Ampz 18.8-11 a 35.0 os 1N000u w•Q 32 - N A 32 0.9d d 0.80 35 x 0.90 x 0.80 = 26.4 15.0 Ames<26A Amps SOO 0.57% �C�I CONDFICTORSPEaFICATiONS REQUIRE➢CONDUCTDRAMPACm` ANNAtl1VCHECK#1 CONDUCTORTEMPERATVREDEFI CONDURFILLDERATNG�-ND.COF ECTEDAMPACITYCAICULA M EM 2 TAGEDROPAG tlRCUR tlRNRDEsmNAmON TENp tpusE ' of sue NR OluTap . Axs _ rtMPoDNou DERATROED dOFOPoGIN30YH0. OUTMNRRFMPE RR NT PEp NP0.Exi XP< OPNITENNRONMENi .NIGH DP[MnNG NRpERIOx UxGRwNOT. NNDUROPOANW �RT �.AR" =Nn4a AxTM'wr' -DQ 3RFrn 0 DIAT A ° Tr (STANAS INVERTER 65 a11020 wFl ER - 420 Mos x 1.25 =52S0Nms52.5 wz9s< 65 MpsooRs(wO T� so.s0.2 a Nx03Rav 3000R1100� 65 n D0.% x DLOD = 63.1 A, ros 050n1F 0.8616 EH Contractor. WARNING &WARNING ELECTRIC SHOCK HAZARD ELECTRIC SHOCK HAZARD R E VO LU(S-U N FAWAUNDFAULT ISMCATEDDO NOT TOUCH TERMINALS A BOTH THE LkE NORALLYOOMEOOONXCTORS AND I NORTH °RTH AVENUE Y� � BURLINGTON,MA 01803 P:(781)270-6555 REQ'D BY:NEC G90.5(C) �- REQ'D BY:NEC 690.13(13) �� REQ'D BY:NEC G90.13(5) �� REQ'D BY:NEC 690.17(E) �� REQ'D BY:NEC G90.3 I(G)(3) �� �,Ma55xtw—ttS.Revck,5un.com APPLY TO: APPLY TO: APPLY TO: APPLY TO: APPLY TO: INVERTER(S),IF NOT APPLIED BY MFR DC DISCONNECT SWITCHES AC DISCONNECT SWITCHES DI5CONNEC(5.PU5E5,CIRCUIT BREAKERS JUNCTION BOXES,RACEWAYS,CABLE TRAYS, CONDUIT BODIES WITH AVAILABLE OPENINGS, EVERY 10',WITHIN POP TURN5/PENETRATION5 PHOTOVOLTAIC POWER SOURCE ProJLLt: WARNING PHOTOVOLTAIC SYSTEM MIT W SPECIFICATIONS DUNN RESIDENCE THIS ELECTRIC SYSTEM ELECTRIC SHOCK HAZARD OPERATING CLFtRENT:22.4 ALPS S CHRISTIAN WAY iHEDCCONDUCTORSOFTHIS THISPHOTOVOLTAICSYSTEM AC DISCONNECT OPERATWGVOLTAGE:350YOLTS NORTH ANDOVER,G- 01845 IS ALSO SERVED BY A PHOTOVOLTAIC SYSTEM ARE EQUIPPED HATH RAPID SHUTDOWN � 'CURRENT' S3 ALPS MAX SYSTEM VOLTAGE 500 VOLTS JOB#:MA02_I G-0024 PHOTOVOLTAIC SYSTEM UMG4WWANDMAYBEE OPERA TNG VOLTAGE240VOITS MAXSYSTEMCUNW., 28 ALPS [-j-t DLtdli$: WIT"8"SPECPICATIONS 10.791 kW5tc, 10.00 kW AC REOV BY:NEC 705.12(D)(3) r REDD BY:NEC G90.35(F) REQ'D BY:NEC r90.12 REQ'D BY:NEC 690.54 OPERATINGCURRENT,8'4 ALPS APPLY TO: APPLY TO: APPLY TO: APPLY TO: OPERATING VOLTAGE:350 VOLTS MAX SYSTEM VOLTAGE 500H7LT5 eenn En Approval: ANY/ALL ELECTRICAL PANELS JUNCTION*COMBINERS BOXES, PV SYSTEM MAIN AC DISCONNECT POINT Of INTERCONNECTION MMXSYSTENCURRENT10 5AypS gIn g ppro CONNECTED TO MULTIPLE POWER SOURCES DC DISCONNECTS,OTHER SERVICEABLE DEVICES REQ'D BY:NEC G90.54 APPLY TO: INVERTER#I REVISIONS DE5CRIPTION DATE REV ORIGINAL 11211201G A EQUIP RELOCATE I /2G/2OI G B EQUIP RELOCATE W 1/27/2016 G Shed TItIL: SAFETY PLACARDS Sheet Number: E2.0 Sheet 5,— AN51 B - 17"x I I" J SIGNAGE REQUIREMENTS JOEL ELH DRAFTING by, HORST I.)RED BACKGROUND 2.)WHITE LETTERING 3.)MIN.3/8"LETTER HEIGHT 4.)ALL CAPITAL LETTERSSCI—PISO 5.)ARIAL OR 51MILAR FONT G.)WEATHER RESISTANT P——d 4 Approved by: MATERIAL,PER UL 9G9 SCALE: 1'=4" EH - Contractor: REVOLU(SUN ataeA.,rRerna e,»r. . RTH AVENUE SUN '• ' SOLAR SOLAR BURLINGTON,ON,MA 01803 P:(781)270-6555 ff www.Mas5achuwtt5.Revolu5un.com SUNPOWER OFFERS THE BEST COMBINED POWER AND PRODUCT WARRANTY G 1 POWER WARRANTY PRODUCT WARRAMY -- HIGH PERFORMANCE&EXCELLENT DURABUN Project: DUNN RESIDENCE 5 CHRISTIAN WAY NORTH ANDOVER,MA 01845 j SERIES xo a 1. N' c v o a to u w ss JOB N:MA02_I G-0024 Mae RusaiMd Pusan 93%for Le 5 yesx CoRbkwd Eorr.r and Product dated 25 yae,eewnYe ProjetDetails: • 20.4%efficiency OA%lyr.w yes 25.1 Ire1 wekAdss pate rpMnerM ones.• 10.791 kW5tc, 10.00 kW AC Ideal for Loots wirers space is at a preordain E LECTRIGIL DATA OPERATING CONDITION AND MECHANICAL DATA ar where burro expansion might be 00Imsw Ta.p.rakRa -40'C b 485C needed. Nomkrd Power's fPnaN 327W 320 W VMb 2100 Po21S kp/P frau b back En rn9 APPol •High psfoxnalRl E2D-327 PANEL Fair-r Title— 46/-0% 4S/-OX Mae led S—5400 Pa,550 kp/ws&.0 Dath.rs aecelerd part.In real world A.U.Panel EBRci.cya 20.11 19.8% imp-i rwlseanAs 25—drawer hall at 23 e1 coadiBons,such as high lemperahxes, HIGH EFFICIENCY' Rated Valteg.(Vnpp) 54-7 V 547V Appesona Class A clouds and ow tjgj s Gerlenala more meter Rawl Cum'finpirl __ 5.98 A_ 5.86 A Sds C b 96 Monocavea m Moxson Gera 1 e Proven value energy par square _ - -.R Voltage IV«1 - _-5.98A_ 64.9 V 64.8 V T Ddidgm i for resNerdfal aaakope,ESwws ESerias net 6%m parcels r par mora sun d 6 b ark"Or OP«hCk ui eupnd Gl.w P 45 hand Sian wryr.d Amie.f WM parents dolMor Tho feakxas,wLo and square o mon power par poral,)and 00'S mon anergy par Mce.sborSkoeB Cunad pscf 100 A 6.24 A C—eaJuncooBox Md5 Ibad ren far a home. squaha rtreer ower 25 years.M' Moa System Vdeape TODD V EC i dOD V tR Parew Mi Pdan1O any Mmdneah States Fuer _ 20 A - Fnwe Close 1 6Pxk anodized(rlBhesF MMA re1Bq) , HIGH ENERGY PRODUCTION' P—,Tatinto el. -0.30%/-C weigh 10,610 Produce more enargy,par rated wan Vdege Tamp Cael. -176A mif/C High year one per(ormarce delivers 74%more energy per toted Caren bop coal. 3.5 aA/C TESTS AND CERTIFICATIONS woes This advantage Increasss our Ran,producing 20%mon Alai'ml Wa IEC 61215,IK 61730,LL1703 WER94CE4 _ REVISIONS energy ar the flat 25 years to meet your needn s� l AB compoe4oen SP%J:40327 vie a rsonewsesa coma rdleel few IS0 9001 X008,150 14001:2004 cE50"171ON DATE REV pawl:2401 qw—1 d ma,15%el�ere�y. ENS Com area RoHS,CNiSAS 16001:2007,6W fn., 2 PYE Iuion Labe--W—ShOdktQ SluI Teo 2013. pR PY CyeM ORIGINAL 1121/2016 A 3 Typically 7.9%—wearily per,Wt,BE1WDPN EMkwafrp--.Pb— Amoral.tea IEC 62716 EQUIP RELOCATE 1/2G/201G e Merem•/s1erC�oPr.deerr4e1%k.r.. Yield Rpar.l 12013' so15 test IEC 61701 Ipassed R-it—snerRYi EQUIP RetocArE It 1/27/2016 c r>oar�kepssfano, desloRlf- ..L-w0.251c erpoddMnax l.OVyrrila pafft pop.syz -_. .war_ 20a� sat-sxrraw.Maai Dgmdaum Ra.,-saibR�.rwMw paper,hb ru tea ....rel.rdlaurdrxxd bpraaaronfres laoDV1O t2ox Mon EnaaY 2013:Jordory drk'beilbeerTae Rspon;NRL4 ORs 2012 h ail ble lissngs TIN.MCS,Ill,JET,KIEM O,CSA`CEC,FSK Engineered for peace d mind t lox ran Rand wan s-nrosnr Modute 404—ILA I Urn 3vdoeer whee paper,Feb Designed b deliver conelislsY,Inoublednare .@ toox ':,•.,••r-•%T 'It 2013•lteehl GM b 99 ad d 100 pa.M opweLte a mon ehon 70%d WOW oYsra velY Torg lfeliRla.i1'a $ 90% �_^~'-: •.. l 135%awn, 6Ouh d pomM Lead MMm-Mwnadael.Pala 2012. Designed for durabdily,Th.Sunk Sola Cd is in cox 1 '-- - 1 Year 25 n 2012(151 parM,102 eompankel,fir 1.lakwnn.9-A Mach 2013. Sheet Title: a*roll bulk an a solid copper foundation. •4:.12CY.1•J 0 C 2caDuprt2xed wah*.Prop is nwmrMa...su.rPbearw—*R.rMa, lam] 1046.. PV MODULE virtually impervious to de earalah and � 6ox 95oee .ire appk7.S---M Eerdwri Y � DATA SHEET ctim&ing 8wt degrade Comanlionai wx JOB leap 8 peel nnnlswe odaawherW by Am Iiii IM'PV peapts.0 o s to Is 20 u Mod le t1x"V Mille"Public Repan,'F.62013. Ywn 1 l eorreeedwith the peril.Alley 234 Om"k Sheet Number: •1 Rarkad in Fwater u+dw dulabMv est.1' gg lox �,r tea nal-L Fib 2011 are mm.�f« 1559 mm D I .O 100%pmak,kaked in Moa 25' 3 Mocctae Nish _ 125wrdrr�ar sd rereCo (1000 WAW kusdlses,AM 1.R 25•�. compnderri,io PVD)anahny WY.11 ex PanemKok rep. (:,- 13 sod al swaps dosed pawerwaluer duAkn oradealen Sheet Size: 6x � uo!".s�aaa ANSI B - 17"x I I" �{High Anr•p.Von ax H eaea.ta,a.whta,d l` ESIGN t DRAFTING BY: 5peaal Repro.15 zx .. AarH�.Raaw JOEL HORST Ser Jh...aneaersteaRVTaskrane—NLraseA. g ox hrA.a.AMws4serereelsibrdrrt...apaRww.r.lkw.W.Rl tetelsRen srexAdEeekAeulnKpedd. .eeIDtse.wwr6eaAr 'N 40rr71n AunpOwsmwILcNNn s npravamreorp.co SEPIS Reviewed 4 Approved by: Eli Contractor: REVOLU(SUN �aa�,.ertwrte<.aPlar. , I NORTH AVENUE BURLINGTON,MAO 1803 solar • • r Single Phase Inverters for North America P:(781)270-6555 solar • • T • SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-USI www.Ma5uchu5ctt5.Revolu5un.com SE7600A-US/SE10000A-US/SE11400A-US SE3000A-US I SE3800A-Us I SESIx10A-US I 5E6000A-US SE7600A-USSE16660M US SE11400a-U6 OUTPUT Nominal AC Power 01 3WU 38rx, 5000 6060 1600 vgN114P 21teV 11400 VA SolarEdge Single Phase Inverters . ......................................................................................... ...................... . =Q«............................. 54(x,W240V �� 1rL^lln m12(IRy Max.AC Power OVtnut 3300 4150 6000 8350 12000 VA For NOftll AfT12(IC8 s4so.a979ov...................................3o9so.k Qo.............................. ProJect: AC OVtPut WltaBe Min,Nen..Ma.... SE3000A-US/SE380OA-US/SE5000A-US/SE6000A-US/ 163-26u,.1.. ' ' 5 CH REBIDENAY ......................................................................................................................................................................... aeoutpmvoluFeNun:Nam:Max.»� 5 ChRISTIAN WAY I ♦ ♦ I SE760OA-US/SE10000A-US 1 SE1140OA-US zoo-zsavac NOJOB ANDOVER,G- 01445 .........................................................................59.3 ......-.....................................-.............................................. AC rre.)Pe yMln:Nom,MaxJ'i 59.3 60 GOS)vAth Hlcam[ry sattln65];6D 60.5) Ni JOB#:MA02 16-0024 nc 24 @ 20SV 40 @ 208V Max.[onnn.wus d.tput Current 1... .- .-16 ., 25 .,- ,3.. 47.5 A ........................ .........31.@.3Soy ........9b@xng.Y................................ ProJect Details: Gf01 Tl.resbuld 1 A unu Mnmtrxm,Isonal Irpeemnn,enunH conn amble mre4hnlAx vas vas 10.791 kWste, 10.00 kW AC INP ml term e 1 ss..l nlrroCndM.............4050.......,..SIOD...........6]50............8100..........]0250..........13500............15350.........H' F ..... _ -•�2, M 1 n Iv It+g 506 vAa ngin eernj Approval: ................................................................................................................. ............................................325 208V(350, 240V...........................-...................V...... 16.5 @ 208V 33 Ea 206V Max.InPut C.nn—'e' 9.5 I 13 itl I3 I 34.5 Ad, ...................................................................... ................................. P..:S AMY...........I........... ........ Max.Input Short Orcuit Current 45 Adc .................................................................................................................................................................... . ........... a ` Reverse-Polarity , ..Yes........ ........................ 9 .................. ... ........................................................ Y............................. .......... Grwnd�F,xNs Isdanon DetttHon (AHAa SensiHvi[ fF('.WeifhlM rlHrlenrY ..................97 "".""v"v..e............�.�....... .............................. .qy.A4.7.QQY....,.............................97:SJfl,�4?.Y............................... Ni hMme Pmver[om.rm tbn <2.S e4 W ADDITIONAL FEATURES ® SuPPorled CPmmunnatbn Interkces ft5485 0.5233 E h ZiQu (°�nO I'.. _ Revanue Grade Dam.AN51 C121 opo I .. ........................ ... .. .................................................... ... i ! 1,,Id Shutdown-NEC 201469012 Funcn..Ift er.ableewh,dSPlarEdg...Pid Onndown xit is mstalledn' STANDARD COMPLIANCE REV 151 ON5 Salety Ul]]41,UL1F940,041990,CSA 22.2 Dt5CRIPTION DATt REV G Id Connection Suntlards IEEE1547 ...1... ............................................................................................................................................................ ORIGINAL (IPI/1016 A + t Emissions FCCpe SclassB INSTALLATION SPECIFICATIONS EQUIP RLLOCATt l (/26/2016 A[outpN condultsbe/AWG ran 34"minimum/166 AWG S/4'mmlm.xn/b3 AWG COMP RELOCATE II 1/2]/2016 G .....................................6°............................../............................................................................. ............... oc moot[Pne�It sbe/xorsnm�/ - 3/4•mmimum/1-z:mn�/ .................................................................................. ...........3/4.-mrNm.xn/1,Z strm�/11i6 AWG aw,r..a9d^............. 73-.h,5.1.-.............in/ ................................. Dimensions with Safety Switch 30.5x 32.Sx 10.5/ In/ 3n.5x12.5x2.2/TI•ix3i5x184 ..lypwxnl................................................................ .. .. u5a."thha2M.4............!h!^.... ................................. Woi�ht with Snkty Switch.......................51.2/Z3:?..........I...................5+.7/24:?.... ...........88:4./40:1........ • • Netwal . -- e[nop C-ons Nnlur.A Car d.. and iniemal fans(n. n,Pincnablc) Sheet Title: The best choice for SolarEdge enabled systems Nae anwae[ PV INVERTER real45eeM4)................................................ �° d� DATA St1EET ...............................nnu.....................................<2.`5................................................................................................. Integrated arc fault protection(Type 1)for NEC 2011690.11 compliance Mln.Max.Operann{Temperature 13to+140/-ZSto+60(-401o+6pversionaval......) -F/-C Superiorefficiency(98'.6) ..Pan¢P........................................................................................................................................................................ Pmtecnm.wnns .....................................................NEMA3R .......... heat Number: Small,lightweight and easy to install on provided bracket ........................................... ......................................................... Built-in module-level monitoring =b2.0 D2.0 Wpe. �b w xµeM�F[romuost. -Internet connection through Ethernet or Wireless heet Size: Outdoor and indoor installation S Fixed voltage inverter,DC/AC conversion only ANS 1 5 — 17" x I III Pre-assembled Safety Switch for faster installation Optional-revenue rade data,ANSI C12.1 JOEL tDRAFTING BY: g (b`"_'�s;unscec • JOEL HORST USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredge.us 11 Reviewed 4 Approved by: _ Eli _ Contractor: REVOLASUN banar.amerter.solar. tg $ I NORTH AVENUE solar solar solarEdge Power Optimizer BURLINGTON,MA 01803 � � v P:(78 I)270-6555 Module Add-On for North America www.Maeeachu5ett5.Revokmun.com P300/ P320/ P400/ P405 SolarEdge Power Optimizer P300 P320 P400 P4D5 Iror(d4u11 motlules) IronN Ps,e—r (W72&%tell Irorthln flbn 60..x11 modules) maduks modules) Module Add-On For North America INPUT — - - — - Proect: Rated 1pput D[Power<'!,,,,,,,,,,,,,,,,,,,,,,,,,,,300„ ,-.,.,,,,,320 ,.,,,,,_,.400 ...405. ,,,,yV,,,,,, DUNN RESIDENCE ........... ............. .................... ............ Absolute Maximum input Voltage 48 80 125 Vdc 5 CHR15TIAN WAY P300 P320 P400 I P405 =f (Vx at lowesttemperature)...................................................................................... ......................................... NORTH ANDOVER,MA 01845 ........... -da MPPTOpe bngRange.........................................R ?8..................................x.:80..................12.5;105............Vdc..... JOB N:MA02_16-0024 Maximum Short Clrcult Current Ilscj SO ( 11 10 Adc ..............................................................._...................... .........Adc'... Pro-t Deta,l, MTxlmum OCl put,Current........ ...........12.5..... ....... ....13.75......... ......................12`'.... ..... ....Adc.... J ffi Maximum E.... 51'............ .......... ............99:`t............................................................°'�....... 1 0.79 I kW5tc, 10.00 kW AC .v Weighted Efficiency 98.8 % Overvolta a Cate o II OUTPUT DURING OPERATION POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Engineering Approval: r. Maximum Output Current ,.15 Adc, .......Output Voltage .......................................... .................... .................................. Maximum Output Voltage GO � 85 Vdc t'. OUTPUT DURING STANDBY JPOWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF_ (' Safety Output Voltage per Power 1 Vdc Optimizer STANDARD COMPLIANCE EMC FCC Par[75 Class B,IEC61000-6•Z,IEC63000-G-3 ,Safety-.......,,„....„..... IEC62109-3(class II safetyl;UL3741.............................................. RoHS Yes INSTALLATION SPECIFlCATIONS Maximum Allowed System Voltage,,,,,,,,,,,,, ............1000..........................................................Vdc ,,,. Compabble nverters All Solarkdge 5(ngle Phase and Three Phase ireerters L zH) Dlmenslons(W 128 is 152 x 27.5/ 128x 152x 35/ 128 x 152 x48/ ' zmm/in Sx5.97x1.08 5x597x1.37 Sx5.97x1.89 REVISIONS ............. .Welght.linduding Cables),._._........ ,,,___,,,,,,,,,,,770/1.7. .......__„_-_930/2.05,,,,,,,,,,,,,,,9 Rt/ . ...,.-...._gr/Ib.„ DE5CRIPTION DATE It, ........... N1C4Compatt!61c, .......................................... ............ ......... .................. ORIGINAL 1121/20 1 G A `' Out ut Wlre a Connector Double Insulated MCI Com atible „ ....p..........ryp.( ..................................... ........ ......... ..p......................................................... EQUIP RELOCATE I 1/26/2016 B Output Wve length . 0953.0 ' 1.2/ ............... , ,,,,,,,, , ................... ,,.,,,.,,,...,,.-,.-.-. 3.9.................. EQUIP RELOCATE 11 1127/2016 c Operating iomperature Range............... ... ............. ............................................ F. C(.. ... sd Protection Rating............ ......IP68.(.NEMA6P.............................................................. MIatIVq Humldlty........................ ..................................q:.100 %...... ne srccaw.rorm.mxem.,mmm.ar do m.sxwwrr rm.rxn<x xlw..a. PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTERIu 5heet Title: Minimum String Length 8 10 18 OPTIMIZER (Power Optimizers)_..,.. ............................................................................................................................................. PV owero timizationatthemodule-level ..(>RYrtumstringlengtn 25 25 50 DATASHEET p P (Power Op mlze s).......................................................... ............ ........................................................................................ Sheet Number: –Up to 25%more energy Maximum Power per,5tring-, ,,,•.,.,,,1250. ,,,•,,,,,,,,,6000 ,,,,•,.•.,,,.12750 W...... .............. Yes................. ...................... Paralle –Superior efficiency or Orientations nssofDiffereatLengths D3.0 ..rOri.ntati.............................................................................................................................................................. - Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading x..xwnww.du,-�.rdas,'.'rworvaaYramrv,00man.r.ixx Sheet Size: –Flexible system design for maximum spate utilization AN51 5 - 17”X I I - Fast installation with a single bolt – Next generation maintenance with module-level monitoring DE51GN t DRAFTING Br: /I s – Module-level voltage shutdown for installer and firefighter safety JOEL HORST J/(J �l'l;v��7E1hn USA GERMANY ITALY FRANCE - JAPAN CHINA ISRAEL AUSTRALIA WWW.SOIaredge.u5 .. .. .. ...,... SEPISOLAR Reviewed 8 Approved by: Ell Contractor: REVOLU(SUN I NORTH AVENUE ENIRLINGTON,MA 01803 P:(781)270-6555 215° www.Mjswbuxtts.Rtvohnw.com Protect: DUNN RE51DENCE 5 Cn R15TIAN WAY NORTn ANDOVER,MA OI 845 JOB#:MA02 16-0024 Protect Details: 1 0.79 1 kW5tc, 10.00 kW AC Engmeermg Approval: REVISIONS DESCRIPTION DATE REV ORIGINAL 1121/2016 A EQUIP RELOCATE I 1/26/201 6 b EQUIP RELOCATE II 1/27/2016 C Sheet T1tic: OPTIMIZER SHEET heet Number: Sheet 51zc: ANSI B - 17"x I I" ESIGN<DRAPLING BY: /) JOEL noRsr SEM Rcvlcwed 6 Approved by: _ Eh - PROJECT DESCRIPTION Contra°` THIS ROOF MOUNTED PHOTOVOLTAIC (PV) SYSTEM IS TO BE INSTALLED AT THE SINGLE-I'AMILY DWELLING IN NORTH ANDOVER, MASSACHUSETTS. REVOLU(SUN THE ENERGY PRODUCED BY THE PV SYSTEM SHALL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ON-SITE ELECTRICAL EQUIPMENT VIA .r'�„.'.o.' A SUPPLY SIDE CONNECTION IN THE MAIN SERVICE PANEL. THIS PROJECT DOES NOT INCLUDE STORAGE BATTERIES. I NORTH AVENUE BURLINGTON,MA 01803 SHEET INDEX SCOPE OF WORK CONSTRUCTION NOTES P:(781)270-6555 T I.0 COVER ( ) 33 FV MODULES(TOTAL: 580 50. ff.) 1.)CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO www'M�Ssachu5etts.Revo4rJun.com A1.0 SITE PLAN (1) 1 O.O kW INVERTER INITIATING CONSTRUCTION. 2.)CONTRACTOR SHALL REVIEW ALL MANUFACTURER INSTALLATION A I.I ROOF: PV LAYOUTS (33)50LAPEDGE POWER OPTIMIZERS DOCUMENTS PRIOR TO INITIATING CONSTRUCTION. A2.0 MOUNTING�RACKING METHOD (74)ATTACHMENT POINTS @ 48"O.C. MAX. 3.)ALL EQUIPMENT SHALL BE LISTED BY U.L.(OR EQUAL)AND LISTED FOR E I.O ELECTRICAL DIAGRAM (1)AC DISCONNECT, 240 VAC, NEMA 3R ITS SPECIFIC APPLICATION. 4.)ALL EQUIPMENT SHALL BE RATED FOR THE ENVIRONMENT IN WHICH IT [N:ORTH E2.0 SAFETY PLACARDS (1) LOAD CENTER, 240 VAC, NEMA 3R I5 INSTALLED. DUNN RESIDENCE D 1.0 PV MODULE DATA SHEET (1)PV METER, 240 VAC, NEMA 3K 5.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE 5 CHRISTIAN WAY MANUFACTURER'S INSTALLATION INSTRUCTIONS. ANDOVER,MAO 1645 D2.0 PV INVERTER DATA SHEET JOB u:MA02_1G-0024 G.)ACCE55 TO ELECTRICAL COMPONENTS OVER 150 VOLTS TO GROUND D3.0 SOLAREDGE OPTIMZER DATA SHEET SHALL BE RESTRICTED TO QUALIFIED PERSONNEL. [-j-t D&A, 7.)ALL CONDUCTORS SHALL BE COPPER,RATED FOR GOO VOLTS AND 10.791 kW5tc, 10.00 kW AC SITE SPECIFICATIONS 90°C WET ENVIRONMENT,UNLESS OTHERWISE NOTED. PARTS LIST OCCUPANCY CATEGORY: II 8)WHERE SIZES OF JUNCTION BOXES,RACEWAYS,AND CONDUITS ARE NOT SPECIFIED,CONTRACTOR SHALL 51ZE THEM ACCORDING TO Englneermg Approval: Quantity De5criptlon DESIGN WIND SPEED: 100 MPH APPLICABLE CODES. EXPOSURE CATEGORY: B 9.)PV MODULE FRAMES SHALL BE BONDED TO RACKING RAIL OR BARE 33 SolarEdge P400 GROUND SNOW LOAD: 50 1`51' COPPER G.E.C.PER THE MODULE MANUFACTURER'S LISTED INSTRUCTION SHEET. 45 PV Module 10.)PV MODULE RACKING RAIL SHALL BE BONDED TO BARE COPPER 74 QMPV Classic Comp Flashing G.E.C.VIA WEEB LUG,IL5CO GBL-4DBT LAY-IN LUG,OR EQUIVLENT L1 TED LUG. 74 Unirac L-Foot GOVERNING CODES 1 1.)GROUNDING ELECTRODE CONDUCTOR(G.E.C.)SHALL BE CONTINUOUS 2014 NATIONAL ELECTRICAL CODE AND/OR IRREVERSIBLY 5PLICED/WELDED. 74 5/1 G"Lag Screw 780 CMR, 8th EDITION 12.)ALL JUNCTION BOXE5,COMBINER BOXES,AND DISCONNECTS SHALL BE INSTALLED IN AN ACCESSIBLE LOCATION. 246 Feet of Unirac SunFrame Rail UNDERWRITER5 LABORATORIES(UL)STANDARDS 13.)ROOF ACCE55 POINTS SHALL BE AT A STRONG POINT ON THE 05HA 29 CFR 1910.269 BUILDING AND NOT REQUIRE THE PLACEMENT OF LADDERS OVER EXTERIOR PEV1510N5 WALL OPENINGS. "5""ff'ON DATE REV 14.)WORKING SPACE AROUND ELECTRIAL EQUIPMENT SHALL COMPLY WITH ORIGINAL 1/21/2016 A NEC 110.2G EQu1P RELOCATE 1 1/26/2016 e EQUIP RELOCATE It 1/27/2016 C l �• �+ ,.,,. Sheet Title: j --" -�• COVER # heel Number: / 5heet Size: _0 ANSI B - 17"x I I" T " �„ ru..""- c� ✓ DESIGN{DRAFTING BY: /1 c i , e !f `e-." Lr"' t''.. I` ,+� ,.� '^•.� . JOEL HORST SEPS Reviewed b Approved by: PARCEL MAP AERIAL MAPE VICINITY MAP PROJECT LOCATION n EH Contractor: 200'TO CHRISTIAN WAY REVOLUCSUN °er,.r—— I NORTH AVENUE BURLINGTON,MA 01803 P:(781)270-6555 215° www.Ma552chu5ed5.Revok5m.com Project: DUNN RE51DfNCE 5 Ct1R15TIAN WAY NORTYt ANDOVER,MAO 1845 JOB#:MA02 I G-0024 70'-9'' Project Deta 1, 10.791 kWstc, 10.00 kW AC 3/4"EMT THROUGH ATTIC UTILITY METER DOWN CHASE TO BASEMENT MAIN SERVICE PANEL Engineering Approval: AC DISCONNECT I PV METER //7I INVERTER W/OC DISCONNECT PV LOAD CENTER —— REVISIONS DE5CRIMON DATE REV ORIGINAL 1/21/2016 A DRIVEWAY --- — 48'-4" EOUIF RELOCATE 126i201G B PV ARRAY FOvIF RELOCATE II 1/27/2016 C OPTIMIZERS UNDER PV MODULES JUNCTION BOX 36°PITCH TYP. hcct T1tic: SITE PLAN Sheet N-1,— A1 .0 umber:A1 .O Sheet 5.— AN51 B - 17"x I I" ESIGN<DRAFTING BY: /I/ JOEL HORST �^1n G ft 12 ft 24 ft K—E-1<APP-1 by: SCALE: 1"= 12' EH 15-3" Contractor: RIDGE 4MAX. — —t1'-4"TYP. f I I i I I I I I 11 11 11 REVOLU(S—UN rIt II r II II r 1 II II F-P, II II F- �.�..ma„... .. . I NORTH AVENUE I I I I II I I I i I BURLINGTON,MAO 1 803 I 1,7-2" I I P:(781)270-6555 11 1 11 II 11 11 II 11' 11 II II II 11 11 1 11 II II II II II II II it II II 11 I II www.Massachumtts.RevoWm.com 1 II II II II II II 11 II it II II II I 11 I 11 II 11 II II II 11 11 II II it it 11 11 i II II It j I It i II II i 11 11 FIT, II II 1 IT II 11 1 fi I i It �� II II I II—II II II II II it IFI j1 11 it 11 ii 1 it it II ProJect: 1 24'-O I I DUNN Rf51DENCE II it II II I 11 II II II II 11 I 11 II it II II 1 1 II I II 174" s cr RISTIAN WAY 1 I I I (I 1 11 I NO TH OB#N MA02R I G-0024MA 0 45 11 II II I I 1 II II II II II 11 II II II it 11 II i II II I it - 1 II II i I _ 11 II II II II FLT, II II _Ii it 11 II I it II 11 11 Project Details: �l i II T II 11 11 II T II II II 11 T i 11 11 IT, I II IT 11 II I g 11 10.791 kWEitc. 10.00 kW AC 11 �l I II II 11 it I U II II II II 301.1 0311 II 11 11 II it I it it 11 II I II II ErNI—r-3 Approval: II I I I IF—IT 4 11 11 11 1 I I I I I II j II II �I �l I II 11 II 11 II II d p p II II II I II it II II I II II I II II II I II II II ii I II II II 11 II 3G.*PITCH II p p p p 1 11 II II II I II II II II II 11 _ II II i I L II II II D L II II L II II _I 11 p 11 I I II MAIN ROOF L II (I EAvE II 1_ II II it I II II II II II II II II I II I 1 11 i II II 11 II SCALE: I"=4' +_ —� 44'-411 _ 2f 4k 5f LEGEND FLA5111NG RAFTER/TRU55 PV MODULE 23'-5" L—1 I ? REVISIONS 4"TYP. I I DESCRIPTION OATS REV 4'MAX. ORIGINAL 112u201G A —, —, P , —, RIDGE IJ 215° EQUIP RELOCATE I 1/2G/201G e I 1 1 ( I I EQUIP RELOCATE II 1/27/201 G C II II II II 11 II II I II II 11 II 11 II II II it I I I I 115'-4111 1 I I I I II II II II II II II it II 11 11 411 I II 11 II p II II II it II T', I I FIT, I I I I IT I I I F T', I I IT i 11 11 II 11 11 11 11 II II II it 11 Sheet Title: it p p 11 11 11 II I II II II II II U II II II ROOF U II II p 11 p II I II 11 II II II II II p II PV LAYOUTS !>, IT, II II a, 11 11 II II IL 11 11 II II II II I '1 I I I I I I L I I 11 1 11 II II II 11 11 14'-G" beet Number: I I II II IT II II II II IT II II II II II II A I . I II 11 II II I1 II II I II 11 II II II II II 11 II 5hcet 5— il II II II II II II i 11 11 II II II II II II II AN51 B - 17"x I I" rl� 11 II r II II rtE i II f� rte II II II II II II II 11 II II 11 IIDESIGN t DRAFTING BY: /1 II j1 11 11 II 11 11 I II II II 11 it II II 11 II JOEL FIOR5T II II II II II II II 1 0 11 II II U 3G°jPITCIi _II ii _II it II _p II I _II 11 _II II II D U II p '�t»u, I Ti II ' Ti II II I Ti II 1 I Ti II 1 Ti II II II II 11 II . '�'�'""�;► 1� SEMI SOL GARAGE ROOF 2 k 4 It--}�8 ft SAVE Reviewed<Approved by: SCALE: I"=4' EI1 1 1 i t I I I I I I 1 1 1 1 i t Contractor: II it II II II it II II I I I I I I I I 1 1 1 1 i t I I REVOLU(SUN RAFTER 1 14- I I I 1 1 I NORTH AVENUE 1 1 j 1 1 1 1 1 1 1 1 1 I I 1 1 I I BURLINGTON.MAO 1503 TYP PV MODULE 1 I I I I 1 1 I I i t 1 1 I I P:(781)270-6555 -- — -- — -- — www.Missachusdt5.Revok".com II II II II it Ii II I 16"MAX. 4'MAX i i t 1 1 1 1 I it 11 II 11 II II it I II II II II II II ii I I 1 1 1 1 1 1 i t I i I I I Proecc: 1 1 I I 11 1 1 11 1 1 I I I DUNN RE5IDENCE 1 1 I I I I I I 11 I I I I I 5 CHP15TIAN WAY 11 1 1 1 1 i t 1 1 I NOJOB NNMA02R_16-0024 I I I I I I I I I I I I I I I Project Details: I I 1 1 I I 11 I I I I 1 1 I 10.791 kWstc, 10.00 kW AC I1 II II I1 it II II I I1 II 11 II 11 II II I STRUCTURAL CALCULATIONS i t I I I I I I I I I I I I I Enj,n-r,rj Approval: QTY WEIGHT EA. TOTAL II I1 II II II II I1 II 11 II II II II II I PV MODULE 33 x 41.O LBS = 1 353 LBS FLASHIN 11 I I i t 11 I I I I I I I RACKING PAILI 24G x 0.75 LB/FT = 185 LBS L-FOOT i I i 11 r 11 I I I I r--I—I I I I ATTACHMENT 74 x 4.0 LBS = 29G LBS RACKING RAIL I I 1 1 I I i 1 1 I I 1 1 I I 1 TOTAL WEIGHT: 1834 LBS I I I I 1 1 I I I I I I I I I ARRAY AREA: 579 5Q. FT. DEAD LOAD: 3.2 PSF POINT LOAD: 24.8 LBS I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I REVISIONS b nn+-I G In 32 In Dt5CRIPTION DATE REV MOUNTING PLAN VIEW ORIGINAL 121/2016 A SCALE: I"= 16" EQUIP RELOCATE 1/2G/201G e EQUIP RELOCATE II 1/27/2016 C UNIRAC CAP 5 PV MODULE NIRAC 5UNFRAME RAIL 51eet TRIC: UNIRAC LFOOT MOUNTING \ 't' I-V OUICKMO F RACKING ME 110D CLASSIC COMP MOUNT _ 5hcet Number: A2.0 O�\j\ON ROO i / y i COMP05� ALUMINUM PLASG NINheet Slze: OOM �6 00 --- ANSI B - 17"x I I �Cg " MW 55 UG SCREW_ DESIGN t DRAFTING BY: /L/5EALED W/CNEMUNKM (1 ORT EOUIV.) JOEL HORST --- ;�% MOUNTING METHOD MOUNTING DETAIL l SCALE: I"= 12 __ %' 3 �I L " _ '' - SCALE: I"=G" _ --G m--I 1 2 m —�= 24 In—� n 6 In—+ 12 In Reviewed S Approved by: — EH -=EQUIP.GROUNDING CONDUCTOR CIRCI CIRCUIT BREAKER (N)=NEW EQUIP.I(E)-EXISTING EQUIP. LI -LINE I(BLACK) L2 =LINE 2(RED) N�-NEUTRAL MT11TE) ©-GROUND(GREEN) -POSITIVE(RED) E-NEGATIVE(BLAC Contractor: Array Configuration PVMod uleSpecifications Inverter Specifications Power Optimizer Specifications AC System Summary System:10.791 kWstc,10 kW AC Model Number: SUNPOWEREZO-327 Model Number:Solar Edge SE1000OA-US Model Number: Sol arEd eP400 NOMINAL SYSTEM VOLTAGE: 240 VOII REVOLU(SUN Total PV Module :33 Weight: 41.0 lbs Power Rating: 10.00 kW AC Max Input Power: 400 Watts MAX CURRENT PER 690.8(A): 42 Amps Inverter l.D.# Inv#1 Dimensions: 61.39%41.18x1.81 (in) Nominal Voltage: 240 Volts AC Max Voc: 80 Volts DC MAX CURRENT PER 690.8(8): 53 Amps I NORTH AVENUE 0 1803 Inve ner AC Power(kW): 10.00 Module Power @ STC: 327 Watts Max Output Current: 42.0 Amps Max Isc: 10.1 Amps DC BURLINGTON, P:(781)270-0-6555555 PV Power(kWstc): 10.79 Voc(open-circuit Voltage): 65 Volts DC CEC Weighted Efficiency:97.5% Output Current: 15 Amps www.Massacbrcft5.Revok)5m.com Module Total Qty. 33 Vmp(max-power Voltage): 54.7 Volts DC Maximum DC Voltage: 500 Output Voltage: 60 Volts DC Inverter DC:ACRatio 1.08 Isc(short-circuit current): 6.5 Amps Inverter Quantity: 1 Min.String Length: 8 String Qty 2 Imp(max-power current): 5.98 Amps Max.String Length: 25 Q String Length: 12 Mfr Voc Temp Coefficient: -0.27 %PC Max.String Power: 5,250 Watts Max Open Circuit Voltage 500 Protect: DUNN RE51DENCE a Operating Voltage: 350 5 CHR15TIAN WAY 2 NORTH ANDOVER,MA 01845 Max Short G rcuit Current 28.0 JOB#:MA02_I G-0024 Operating Current: 22.4 Prgect Details: String Qty 1 10.791 kWstc, 10.00 kW AC m String Length: 9 H Max Open Circuit Voltage 500 C6 Operating Voltage: 350 TO UTILITY GRID Engineering Approval: 2 - Max Short Circuit Current, 10.5 (E)91-DIRECTIONAL Opera ting Current: 8.4 IBL0.;Gxl£RIOR WNL--- oO UTILITY MITER (N)AC 015CONNECT I-PFIA5E,240 V 'M1aR ( (N)EV LOAD CENTER (N)PV METER I MD jR uarep -" -ON RO""IIN BA-EMENr-- I r < 5 Lc 12o x' POINT OP IMERCOIJrvECTION OiA 3R U�ISTN ? I (N)LINE 51DE TAP Mopuie i(N)INVERTER(QTY I) I 55 A r0[ PER NEC 240.21(5)(1)A 705.12(A) 9pi-.E BE lwro N•EO M1 LENGTH OF TAP CONDUCTORS (N)Co.BINER BOX I°yN x SHALL IJOT EXCEED 10 PT l u - - l I 200 A I (E)MAIN SERVICE DiSCONNf[.T L ns Ep •55 A L - I 200 A,240 V,2-P REVISIONS Bo„BRO 11 � Flxlxc.lurnP[P. I I DESCRIPTION DATE REV • • • • • • ' z E)BUS BARS:200 A I ORIGINAL 1/21/2016 A I 2 12 2 12 2 9 - I -- EQUIP RELOCATE I 1/2G/201G B (E)MAIN SERVICE PANEL EQUIP RELOCATE 11 1/27/201 G G STRING 1:(1)PV MODULE PER OPTIMIZER 5TMNG 2:(1)EV MODULE PER OPTIMIZER STRING 3:(1)FV MODULE PER OPTIMIZER L_- --- (12)OPTIMI2ER5 CONNECTED IN SERIES (12)OPTIMIZERS CONNECTED IN 5ERIE5 (9)OEMWER5 CONNECTED IN 5ERIE5 DC3 3.924-1,TOTAL 3.924 xWatc TOTAL 2.943 kW1tc TOTAL -pN ROOFTOFI IN BASEMENT- 1(E)GROUNDING ELECTRODE 5Y TEM I Sheet Title: WIRE AND CONDUIT SCHEDULE ELECTRICAL COND COND COND GND GND GND CONDUIT CONDUIT E5T. DIAGRAM PV System Maximum Voltage Calculation per NEC 690.7(A) TAG QTY 512E TYPE QTY 51ZE TYPE SIZE TYPE D15T. Sheet Number: Local Record Low Temp: -18°C Data Source: LAWRENCE MUNI Voc Temp 25°C- Voc Voc Number of Termpera lure DC I 2/5TRING AWG#10 PV-WIRE I AWG#G BARE CU WA WA 10 E I .O Coefficient x Record +1 = Correction Correction x Voc x Modules in = Corrected Open DC2 2 AWG#8 THWN-2 I AWG# O THWN-2 3/4" EMT 50 Sheet 512e: Low Temp. Factor Factor Series Ci rcu it Vol tage DC3 2 AWG#10 THWN-2 ANSI B - 17"x I 111 0.27%/°C It 43°C +1 = 1.116 AC 1 3 AWG#G THWN-2 I 1.116 x 64.9 % 1 = 72.4 Volts DO AWG#8 THWN-2 3/4" EMT 50 E51cN<DRAFTING BY: CONOUCTOR SPECIFICATIONS REQUTAEDCONDUC'TORAMPACIW AMPACIIY CNECK tlI CONDUCTORTEMPERATUREDERATING CONDUITFILLDERATING CORRECTED AMPACM CALCULATION AMPACITY CHICK VOLTAGEOROP JOEL HOZ5T CIRCUR6CIRTAG TfMP.ING AOTY� CONBVRDft tlRN1i TING E VOITAGF ORIGIN rER1 = = PnOnDIIATED ro 1 OCI Pv5TN1NG COPPER R90'C AWGp10 Bsom Amss 15ROOT sral1 - 15.0 AT BL25 = SB.80"I 18.8% <40.0AT1pz ROOFTOPREENR TEM33'cx oolvl. o.ss21 54 o.oiOEb a OxN/AOR Nr1.00 ox AM4O rO00.T6fx 0100E=030.4 rr A15.OBNAm <30.4 A 011011 0.11%DC2 COMBINER BOXCOPPER TS'C AWGJIB 50 Amva 15.00 x 2 = 30.0 ATo x 1.25 = 37.5 Amps '37.5 Amvz <500 Amus 32 1 N A F 32 0.94 4 0.80 50 x 0.94 x 0.80 3T.6 s30.0 Amus<32.6 Ampz 50IF 0.21%DC3 COMBINER BO% COPPER )5'C AWGp10 35 Ams 15.00 x 1 = 15.0 Ams x 1.25 = 18.8 Amps 18.8 Amps <35.0 Amps INDOORS32 N A 32 0.94 4 0.80 35 x 0.94 x 0.80 = 264 Am 15.0 Ampz<2h.0 Amps 1.1, ^�I CONDUCTORSPECIR01IMONS REQUIRED CONDUMRAMPAOIT AMPACIT/[ME[K Nl CONDUCTORTEMPERATUREDERATING L-E` OUR FILL DERATING COMECTEDAMPAoWCALCUTATTON AMPACITT CNECKK2 V0 TAGg DROP OReun AAo RTER Neu Loeu:x ANPAG T. AOF AMPA Tr NNDu1T TAG CIRCUITDESBNATION � LRs%PER NNpDE1oP TING �� OEBUCTC N[swnv Reviewed S A OVed b ORIGIN MATERIAL TEM° TIRADE 30'CRR uiPUT r O •NRRENT PERT - RFN NT PER NRRx ORNITENVIRONMENT .R M NMERION ROUNDED RIO Eq� FILL NNDU NRR NTP <OxpuC[pR ACC PPr Y: ATNG SNE RT 600.8(e)(11Ia1-N 1 690 tlTv EMPYO 1)0,1 B0150 3 a A ERATE ADN 69pa 3 OTv DIBTANCF VDRD ACl INVERTER SPDCEwITNExISnNGCONDLx:T0R5 COPPER R75'C AWG PS Bl4se�Rs N420 WEIPER = 42.0Mips x 1.25 -E52.SONros 52.SOMps< 65PAAmps DDn5N0'O TfG32GN OTf 32 0941 a030oRs 1�Ril%1 X65 nR 00.94E x O1.CO = 6L3 42.OBNros< 61.lAAmpz SOn 0.8G% EH Contractor: WARNING AWARNING �- ELECTRIC SHOCK HAZARD ELECTRIC SHOCK HAZARD R E VO LU q SU N IF A GROUND FAULT IS INDICATED DO NOT TOUCH TERMINALS NORMALLY GROUNOEDOONDUCTORS TERMIN48 ON BOTH THE LINE MAYBEEMOMMANDAROUMEP AND LOAD S106MAY BEEIIFRGIZED I NORTH AVENUE BURLINGTON,MA 01803 REQ'D BY:NEC 690.5(C)��I�I REQ'D BY:NEC 690.13(3) 2 REQ'D BY:NEC 690.13(B) ��J�I REQ'0 BY:NEC 690.1 7(E) P:(781)270-6555 4 REQ'D BY:NEC 690.31(6)(3) g �,.N.MnSvchuxttS.Revo4nun.com APPLY TO: u APPLY TO: APPLY TO: u APPLY TO: APPLY TO: INVERTER(S),IF NOT APPLIED BY MFR DC DISCONNECT SWITCHES AC DISCONNECT SWITCHES DISCONNECTS,FUSES,CIRCUIT BREAKERS JUNCTION BOXES,RACEWAYS,CABLE TRAY5, CONDUIT BODIES WITH AVAILABLE OPENINGS. EVERY 10',WITHIN I'OF TURN5/PENETRATION5 WARNING PHOTOVOLTMCPOWERSOURCE P J-t PHOTOVOLTAIC SYSTEM IPUTWSPEGFICATIONS DUNN RESIDENCE THIS ELECTRIC SYSTEMELECTRIC SHOCK HAZARD AC DISCONNECT OPERATING CURRENT:22.4AMPS 5 CHRISTIAN WAY IS ALSO SERVED BYA THE DC CONDUCTORS OF THIS THIS PHOTOVOLTAIC SYSTEM �¶ � 53 AAPS OPERATBNGVOLTAGE:350Vt)LTS NORTTHAJOB ANDOVER'I6-002445 PHOTO TAN;SYSTEM PHOTOVOLTAIC SYSTEM ARE EOUPPED WITH RAPID SHUTDOWN OPERATWG VOLTAGE 240 MILTS MAX SYSTEM VOLTAGE:500 VOLTS – UNUNDE GRODANDMAYBEENERGDED MAX SYSTEM CURRENT 28 AAPS Protect Details: MPUT"8'SPECPICATIONS 10.791 kWst., 10.00 kW AC REQ'D BY:NEC 705.12(D)(3) REQ'D BY:NEC 690.35(F) REQ'D BY:NEC 690.12�(-�V I REQ'D BY:NEC G90.54 KERAT�CURRENT:8.4 AAPS APPLY TO: �� APPLY TO: 7 APPLY TO: u APPLY TO: u OPERATING VOLTAGE:350 VOLTS ANY/ALL ELECTRICAL PANELS JUNCTION 8 COMBINERS BOXES, PV 5Y5TEM MAIN AC DISCONNECT POINT OF INTERCONNECTION MAX SYSTEMVOLTAGE.50O VOLTS En Ineerin A oval: MAX SYSTEM CURRENT:J 0.5 AIDS 9 9 ppr CONNECTED TO MULTIPLE POWER SOURCES DC DISCONNECTS,OTHER SERVICEABLE DEVICES REQ'D BY:NEC 690.54 APPLY TO: INVERTER NI REV15ION5 Dt5CRIPTION DATE REV ORIGINAL 1/21/2016 A EQUIP RELOCATE 1/26/2016 5 EQUIP RELOCATE 11 1/27/2016 C Sheet Title: SAFETY PLACARDS Sheet Number: E2.0 heet 51— AN51 B - 17" x I I" 51GNAGE REQUIREMENTS JOELHOR5AF1NeeY: 1.)RED BACKGROUND 2.)WHITE LETTERING 3J MIN.3/8"LETTER HEIGHT 'v 4.)ALL CAPITAL LETTER5 5.)ATRIAL OR 51MILAP FONT G.)WEATHER RESI5TANT MATERIAL,PER UL 969 Reviewed 4 Approved by: SCALE: I"=4" EH Contractor: REVOLU�SUfV ban.r..m.nar..aar. •• • s•WE e I NORTH AVENUE SOLARSUN SOLAR f BURLINGTON,MA 01803 P:(781)270-6555 nn www.Ma55achu5ett5.Revolu5un.com Y SUNPOWER OFFERS THE BEST COMBINED POWER AND PRODUCT WARRANTY YY r POWER WARRANTY PRODUCT WARRANTY HIGH PERFORMANCE&EXCELLENT DURABILITY 00f �, 9 Protect OUNN Pf51DENCIf . u7� 5 WAY E O L NORTYi ANDON[)O VER,EP,,MA 01845 SERIES o a 10 x•.m 20 v o a 10�•a 20 2e JOB N:MA02_16-0024 Man W-A d power.93%her&W 5 y-, Cam66md Fberer and hodiq debd 25 yo c-age Project Deta115: •20.4%enktonq 4L42i/yr.b year 25.s ha lazed"Pa.N replounrnt mtls.' 10.791 kWstc, 10.00 kW AC Ideal for mobs whsle apace A of a prewurn ELECTRICAL DATA OPERATING GONIXr1ON AND MECHANICAL DATA or whale f viuns enponabn might be owv nwuo �� Tespnmlun -40'0 b♦BSC Nominal Paw-tel 327 W 320 W yWMd;2400 Pa,240 Wins froM3 bock Englneer,ng Approval: •High parfom ones Eta-327 PANEL Power 11011,00cs +5/-0% a3/-0% Mw low Swvr.SA00 Pa,350 kp/m•Tran Delivers woodent performance In red wart d Aq.Panel ERkNmy° 20.4% 19.8% hrlp d-kb- 25mm dbnrrw hot a 23 V. aordarons,such as high temperate es, HIGH EFFICIENCY' Rand Y.IVW(V.W) 54.7 v 5,47V clads and low IrgH.1=e Geoea�more,moerntrgy per sgjons motor Ral.d Current pmPp(,_ _ 5.98 A 5.86 A Sala GM 996 MMaweryNo94w Matra)Oen E •Proven value Op-CT-v V-11w.IV-) 64.9 V 64.6 V Tampered tike" High IronsmWbn mmp•nd AMMWodko Designed for Isadeneal raohops,E,%wIwpanels ESeries readennal prods convert toss sunlight b eleelncly dolivw am fookims,valuo and pnodueirng 36%more power per ponel,I and 60%more energy per ShatCkeu4 CwreM 04 6A6 A 6.24 A 1une8°n Bol IPAS Raid square wow s ^over 25 years." Mara BY-VaaoOe 1,000 V IEC a 600 V UL � _ C-leck m MC4 P°1bOf1^OAG° °°Y home, Mm itnum Serf"Fu" 20 A Fm- Class 1 black anodized(hlah"f AAMA mIleR) HIGH ENERGY PRODUCTION' p-,T.mPCad. -0.30%/ 'C We10M 16,6ko Produce mom energy per mind wan vdrope Temp Cod. -176A mV/•C . High year one performance delivers 74%more energy per noted Cun.nt Temp Cwt. 3.5 elA/•C TESTS AND CERTIFICATIONS wan."This advantage Increases over Time,producing 20%mom REFEREINICE& Slaldmd Irm IK 61215,IBC 61730,LR.1703 energy over the NM 25 years to meetyour needs! IAN copearboe ere SPR.QO 27 vera rep"r4NM a-wines) 4uo167 MY ISO 9001:2008,ISO 14001:2004 REV1510N5 m5CRIf T10N DATE REV panty:240W,oppnc 1.6 tot,15%eTadusy. RoMS OHS"I SWI:2007,I.ad Fres, an lab.--W- PVCycle ENS CorrltAlarree ORIGINAL 1/21/2016 A 2PA-101 Sle- Sludy,•Talo 3 Typkdly 7-9%mala enW�.PYx'NLft BEW/DNy bIQifYvire Rdllg'SeiP°Ymr EQUIP RELOCATE 1/26/2016 B �es^/NesC•ae Ari�Yyk✓r• 1610 Repan:Jan 2013. A.-d.hal [C 62716 EQUIP RELOCATE II 1/27/2016 C 6p45w11b.w O=Wdgod°eonval.Dlk/yr pa LCompeon,7 So05pmybw IEC 61701(passed rowel-aawlly�__ I2Q% Nal.--Pa Module Degmd°lore Roe,'7ualbwwvhft paper,Feb PD fad ...PaMdld7nduad Degrodallen Tore l000V- 120% w Report"M2 Engineered for pecan of mind \ 1 rox wmRaEroed�my �1' 3un MoJJordan, kuIs 40-Y TiiN1d � w4wr�wti�ilpapr.robJET,REMCO,CSA,CEC,FSEC, Designed b dekver corlstaleM,imubWnes loox °%"'""'s"`7 x20133.UsahA R is 99 cul f 100 pawb opRr A al-11-7016al AvaTlabls Balrips TIN,MCS,ul.,_.-----.. wmgy am a very long IAalims. - --- " 1 a vel of a 260,0 pans IYd in Ttcbn kilwrclTad.Pab 2012. Designed for duer -Wab* -R vox --_-`- .l y-25 7 8%m -rim,thm*A W Gf On tap 10 pwA compsL d" Nsd The SunPovPw AAmeon Solar Cell Is M 8 In 2012(151 p-*102 aw"Or"4,Phobn InlawMd,AMroh 2013. 5heet Titl Qtly cell bort an a wild wppwfoun dation. >'0% Pi A1C•1:F1 �Ce2m01p.%ed weh err up is manNaM..a.s.,Paw.rw.mdy n rT.w 1046.. PV MODULE Virtually lmpervbwbthe convelmand 60% 9S-adriwwapply.Smw nnry1wdNM4 aaddngthat degandecomreMToncl 50%L 105 d"a Pantyeen4oal.w.v %.w wR-dwfrlsE,w DATA SHEET 5 10 15 20 25 ModA•Daml.Fly k1ii011M PuhOR R.pM,•Wb 2,013. Y.O. 71 CmRzeedxMh he mrnNr�.7•.I•d mMd Prowl.Ath"23+O..bmy Sheet Number: ►1 Ranked ta Fraunhafw durobilly Md.'* Irl Rb 2013. 4a mm I« 1559 mm +I 100%pduw maintained In Arkie 25. � 10% ,f Mar,mio.wyh .d� _y� 1251o�drel C,ordeon ngODwAnakmdlsw,AM 1s,2Y G1. D 1 .0 amVIchonsha PVDI Dumisil y tow.'1 ax r.+r"1=•'m Hnyh 11-14. 3' (;l- 13 Bmsd an own"of mson.ed p°wervdu"duh18 p°duabn 6% �No DyhtMdec.d l mobR J Sh AN51 B - 17"x I I" Dey,vd•Nm •by�rt0 4- ) 5p.eml H5,-1R.ym and erpom. DESIGN f DRAFTING BY: 2% JOEL HOR5T TA" �1 HlahYorfwmoM. I Mna•fl.rx..clan .IryyAww,.npa.mlp..mAs w m.ntubae hlemra. > °% ver...drrt...rr4ddN.dwN�..w.e.9a.�p.err.v4N.nes+s.4.M•rarwhrr.Ir..alwwl.S,.wLv4erPmaM. ew.remarsv..as.wnMs..wasu"oweLrwmo.alwmwaftw rrocrwlw.rsRnwLlna..v.er....aNr.es 1i�;YY1n�iC�n ..r..errs.w..cr•+iw4+•r••rsr.lru.f.rr+w.y.+r+.•rwrfw.,� CnCCl1Cl sunpowercorpcom P) Reviewed 4 Approved by: Eti Contractor: REVOLU�SUN Wearier.artserter.solar. I NORTH AVENUE BURLINGTON,MA 01803 _ solar Single Phase InvertersS for North America P:(781)270-6555 solar @@ • SE760OA-US/SE3600A-US/S E1140OA-US 6000A-US/ www.Ma55acbu5dt5.RzvoiLrun.com SE7600A-USISEt0000A-US/SE17400A-US SE300(IA-US S93MA-US I SES000MUS SE6000A-US SE]fiWA-US SESOOOpA-US I SE11400A-US OUTPUT 49xn 4Y 7MV SolarEdge Single ase Inverters ............................. . :��.............................. Nominal AC Output 30W 3800 600D 60L'O ]600 11400 VA 541x1 HMV Inxsxl ml7mly Max AC Power Clutput 3300 4150 5450,m;COy,,,,,,6� 8350 10950�140y,,,-„I?�......,,....,,,, Project: For North America ,...........I....................... AC Wtput Voltage Min:Nan:Max�u 1s3-tog-zz9 vac - - - - - DUNN RESIDENCE SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ . . .................................................................................... AC Output voluge Min:Nan:Maim S CHRISTIAN WAY SE7600A-US/SE10000A-US/SEi1400A-US 2x1-zoo-z6avac .. NORTHANMA02 G- 01845 ACire�ucncy Mln.Nom,Max.I” 59.3,60,M.S.)with Hlcamtry semn657;ED-60.5) Hz JOB#:MA - ................................................................. ........ _ 24 20BV 40�a 200V Max.Continuous ditpllt Grrcent 1.5 --- •16 25 - -37 47.5 A ........................ ..�1.@.1!.Oy................... ........421.x4pY................................ Project Details: GF01 TlucshWd 1 .........................................................................................................................................................................A ....... um11v Mnmrabg.Running Prntemnn,calmo-y c9nnel�am4 mrnnnms re. vn 10.79 kWstc, 0.00 kW AC I�, INPUT Maximum OC Power)STC) 4050 5100 fi]50 8]00 10250 13500 15350 W ........................................................................................................... ............................................................. • .� tramtamnr-Ins,unpamnen, rn Engmeering Approval: ' •,. Max.into[volta9°.......................................................................................................................................................... _� .................... •�`�._3 Nom.OC Inpilt,witage....-..-„ 325(a 308V(3i0 2M1OV .,,., VJc r 16.5 @ 208V 33 208V jr'.' .....9.5............13...... lA ......23 34.5 Al - -�;, ..............Gurem'r'.............................. L.............I,14,5 f^244Y..L.. .........3Ef tm x913y.....,...... ....... Max.Input Shart Orcult Current ••..............45 .Adc ................................................................................... ............................................................. a �� Rsserse•PoRrit Protecdon YN ,....98:3.,.........98:3.............`x.8..............98.........,.....9.............y..... rFr W°Ightad FlXrlencY A>.5 911 4/Acro%IMV 97.5 97.5 9/m>IIXV 97.5 M ............................................................................4d.0..3.4M!....................................?"O.,24oy............................... NI httlme power Conwm Ibn a2.5 a M1 W ADDITIOAL FEATURES ___—._.N—___—_...._ ........__..._.—.- ..._.._..— __.� .....-..- SUPrated Communkatbnlnler(aces 85485.85232,Ethernet.ZlgUce(oP[bnall... Revenue Gradc Data,AN51 p2.1 OPHenallu ......-....1d..-.......0 201469............................................................... .d shutdo--......Ir%mIIed-.................................. !. Rapitl Shultlown-NEC 2014690.12 Funcdonallty enabled when SolarEdge rapid shultlown hit is lnstalledr' STANDARD COMPLIANCE REV I5ION 5 .....1W W: 5nfetY.................... ..............................UL1741_UL109�,.UL1998,CSA22:?...................._............................... D[SCRIPTION DATE REV ......................... .. L Grld ConnecXon Srondartls -..,,..,..ICEE154'i ........................................................................................ ................................................................... URIGINAL 1/11/2016 A + ! Emltsiom FCC'.rU'd—R _ INSTALLATION SPECIFICATIONS EQUIP RELOCATE 1 1/26/1016 B ------- - ------ "" EQUIP RELOCATE II Il27/2016 C ACRTM ..A1WHWaYWfirhYta0w.)gitc,hoSMa/ueltys,5nwei/tcMh.N...!.M...r.e.......................51..2/332.,..,,,...,..................W.,--. .................................. TICnP dt i /N f Ing) 3/."....—/12 1111n .SNg1xFi4 m,14h2u.(mp'v4x/y0<3.6 2101Wg .............. %4 ................................................ wth Safety Switch 0.5x12.1113518M1 .. . ................. . ............. . ........11.1... G..-/.- ....,...m..In..m :.... ...54.7/241 ../.. ..... , .mon Cooling Natural Co—v " °nil ntcrnal funs(userrePl""W) 5h-t T1tle: PV INVERTER repleteebit)................................................. The best choice for SolarEdge enabled systems ;p......... - ................... - --- -- --Integrated arc fault protection .........................................................................<ZS........................................................ ...........................� .... DATA St'1 EET g p (Type 1)for NEC 2011690.11 compliance Min:Max.OPeradng TemperaNre .13 to♦140/-25 to a60 p40ID♦60versbnawllable'"I -F/'C -Superior efficiency(98°.5) ..!Wnge....................................................................................................................................................................... PmM[Xon lGXng ...-.-..NFMA3X ............. Sheet Number: Small,lightweight and easy to install on provided bracket rwmn.elw,I,.�wnry.......n mx,ean,a D 2.0 a,.aaan..n.,9l ae«`..wno..im...w.nnw. -Built-In module-level monitoring MaK��.;;aa..:�u�ni9:s°e...Aumoonnnx lwrli`°"wolwm,.I.:sen4o4us4oxnnnxi. -Internet connection through Ethernet or Wireless ° . i9: 'w:rr++>aIxt°a na xaou'.,.r..nmaausamxw.r. Sheet Sae: -Outdoor and indoor Installation -Fixed voltage inverter,DC/AC conversion only ANS 1 5 - 1 7"x I I" -Pre-assembled Safety Switch for faster installation DE516N<DRAPTING BY: -Optional-revenue grade data,ANSI C12.1 unsxc • JOEL HORST USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredge.us �Y.1 Reviewed L Approved by: _ EH Contractor: REVOLU(SUN "lea"..emarrer.,olar. , I NORTH AVENUE �s1 }{ solar" SolarEdge Power Optimizer BURLINGTON,MA 01803 solarZ@ ® oar 8 ® ® P:(781)270-6555 Module Add On for North America www.Ma5sachusetts.Revolu9un.com P300/ P320 I P400/ P405 SolarEdge Power Optimizer PAoo P320 P400 Pans Ilor 60tell medW�sl (brhlaMpavttr Ibr728%tell Iter thin flan 66rell maaWesl_ modules modules) Module Add-On For North America INPUT .Rated Input OC Power<:1............................300.......................320.......................4 ......................405........... W DUNN RE51DENCF P300 / P320 P400 / P405 ® Absolute Maximum input Voltage ��. 49 80 125 Vdc 5 CFI RISTIAN WAY / ,n: „(Vpc at(owesttemperaturel, ............. NORTH ANDOVER,MA 01845 ..........................................................................................................0......... 9..80......... 12.5.105 ,VdcJOB#:MA02_16-0024 " ro 1t4:,,, Maxlmum Short Clrcult Current hscl 10 I 3 ................. _.......................... ................................................................................................................... ........... .� Maxlmum DC Input Current,,,, 32.5 13.75 12.5 Adc Protect Details: ® Maxlmum Ef9den.S/........................................................................99:$.............................................................°'5...... 10.791 kW5tc, 1 0.00 kW AC Wel�hted Efficiency...........................................................................98:R .........................76 ................................... ....... Overvolta a Cate o II OUTPUT DURING OPERATION POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Engmeenng Approval: Maxlmum Output Curren[ Maximum Output Voltage 60 Vdc A OUTPUT DURING STANDBY POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER Satrty0utput Voltage per Power 1 Vdc "d ® Optimizer STANDARD COMPLIANCE EMC. FCC Part15 Class B,IEC63000-6-2,IEC61000-6-3 ,ya .... .................................................................................................................................................... Saf.................... e ........................................IEC621119.1 class II safer I.UL3741 ; RoHS Yes INSTALLATION SPECIFICATIONS '"`, ;,,' .Maximum Allowed SYstem Volta&e,,,,,,,,,,,,,,,,,,I.......,,,,,,,,,,,,,,,,,,, 1000 Vdc ' Companble nverters, ,,. ,, All SolarEdge 5ingle Phase and Three Phase inverters .......................... ..........................................................,....... 12Ax 152 x 27.5/ 1282152x35/ 126x152 x49/ Dl...... nz(W x L H) mm..In .I Sz5.97x1.08 Sx5.97x1.37 I Sx5.97x1.89 REVI`JIONS ,Weight hnduding cables)......................................77017 .......930/,2A5 ... _930/205.........,.gr,/Ib,.,, 0E5CR1PT1oN DATE REV ORIGINAL u2 u2o15 A Output Wlre'fYpe[Connecter Dnuhk Ins llaMd MC4 Cnmpadhle /26 ,,, e4ulP RerocA7el 1 /2016 e OutputW eleng[h.. ......... ........ 095 30, ..........,I ...... 12/3A ................m/h... Eou1P RELOCATE 11 1/27/2015 c .Operat(ny Temperature Range „ `C%'F ....... ................. ........................... ......... .......... Pro[ecdon Radn ,„, „IP68. NEMA6P Rclanvc HumIAItY......................... ................................fr:.300 ....%...... PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V 10 A SOLAREDGE INVERTERIrI SheeC T1tle: Minimum String Length 8 10 18 OPTIMIZER (Power mString Ler.._. ................... DATA SHEET ................. ......................................................................................................... PV ower optimization at the module-level "Maximum String 25 25 50 P P (Power opt[mlzers)................................................................................................................................................... ”""" Sheet Number: —Up to 25%more energy Maxlmum Power per,5tring,,,,,,,,,,,,,,,,,,,,,,,,,,,5250 ,,,,,,,,,,,,,,6000 ,,,,,,,,,,,,12750 W,,,,,, Strings f ................ Ycs................ ....................... —Superior efficiency(99.5%) ParallelStrngsofl)iHereniLengths D3.0 I ,or Odent,dons .............................................................................................................................. -Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading Sheet Sae: —Flexible system design for maximum space utilization ANSI B - 17" x I I u —fast Installation with a single bolt -Next generation maintenance with module-level monitoring JOEL t10R5T o DRAFTING Br: —Module-level voltage shutdown for installer and firefighter safety USA GERMANY ITALY FRANCE JAPAN CHINA ISRAEL AUSTRALIA www.solaredge.us SEPISOLAR Reviewed E Approved by: EH Contractor: REVOLU�SUN I NORTH AVENUE BURLINGTON,MAO 1803 P:(781)270-6555 215° www.Ma55achusdt5.Rzvok)5Ljn.com Protect: DUNN RESIDENCE 5 CHR15TIAN WAY NORTH ANDOVER,MA 01 845 JOB#:MA02 I G-0024 Protect Details: 1 0.791 kWstc, 1 0.00 kW AC Fngmcering Approval: REV1510N5 Dt5CKIPTION DATE REV ORIGINAL 1/21/2016 A LQUIP RELOCATE 1 1/26/2016 b LQUIP RELOCATE It 1/27/201 E C Shect Titic: OPTIMIZER 5t EET Shect Number: � Sheet Sae: AN51 B - 17"x I I" DE51GN<DRAFTING BY: /1 JOEL HOR5T C•^,1 SEPIS R——f i Approved by: _ E4 The Conimoitivettlth of Massachusetts Department of Luhistrial Accidents Office ofinvestigations I Congress Sit-eel,Srtite 100 Boston, MA 02114-2017 s ivtvlv.iitass.gov/tlia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name(Business/Organizatio»/Individtial): Northeast Solar Services Inc Address: l North Ave Suite A City/State/Zip:Burlington/MA/01803 Phone#:781 -270-6555 Are you an entpioyer?Checic the appropriate box: Type of project(required): 1. ✓� I am a employer with 12 4. [ I am a general contractor and 1 b E]New construction employees(full and/or part-time).' have hired the sub-contractors 2.❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. ❑Remodeling ship and have no employees These sub-contractors have 8. E]Demolition working for me in any capacity. employees and have workers' 9. E]Building addition [ workers comp. insurance.1 eq �comp. insurance 10,[]Electrical repairs or additions required.] S. We are a corporation and its 3.❑ I am a homeowner doing all work officers have exercised their I LF1 Plumbing repairs or additions myself.[No workers'comp. right of exemption per MGL c. repairs insurance required.)t c. 152,§1(4),and we have no Solar PV employees. [No workers' 13.E Other comp. insurance required.] •Any applicant that checks box#I must also fill out the section below showing their workers'compensation policy infomkltion. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit anew affidavit indicating such. tContractors that check this box must attached an additional sheet showing the name of the subcontractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I ant tui enyloyer that is providing nvorkets'compensation insurance for my employees. Below is lite policy and job site int foruration. Insurance Company Name: Federated Mutual Insurance Company IL Policy#or Self-ins.Lic.ii:9884086 Expiration Date:'12/31/2016 Job Site Address: 5 C4F-16'T1At•l WAY City/State/Zip: 0 ,AQPOId�MA t45 Attach a copy of the workers' compensation policy declaration page(showing(lie policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine tip to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. 1 do herebcerci under t airs and enalties o er iet that the ht orinatiot provided above is true and t. id correc Si nature: - - Date: 02 I 10 t to Phone#•781-270-489 Official tise only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of]Health 2.Building Department 3.City/Town Clerk 4.Elech•ical Inspector 5.Plumbing Inspector 6:Otifcr Contact Person: Phone#: '4�� CERTIFICATE OF LIABILITY INSURANCE 0 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW,THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORI2ED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed.If SUBROGATION IS WAIVED,subject to the tet.. and conditions of the policy,certain policies may require an erAorsemPnl.A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsements. PRODUCER OONTACT FEDERATED MUTUAL INSURANCE COMPANY HOME OFFICE:P.O.BOX 328 CENTER--- PHONE st• 4%9 F�No);6074404664 OWATONNA,MN 55060 qo Ais: ENT E R r :DINS.COM INSURERS AFFOROINO COVERAGE MAIC# INSURER A.FEDERATED MUTUAL INSURANCE COMPANY 13935 INSURED 291.67M INSURER S. NORTHEAST ELECTRICAL INC,NORTHEAST SOLAR SERVICES INC EISURERC: 1 NORTH AVE INSURER 0: BURLINGTON,MA 01803 INSURER E: INSURER F. COVERAGES CERTIFICATE NUMBER:64 REVISION NUMBER:2 THIS 13 TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ILIR NSR TYPE OF INSURANCE DL UBR POLICY HUMBER POLICY EFF POLICY EXP LIMBS BF ERAL LIABILITY EACH OCCURRENCE $1,000,0DO X CYMMERCIALTp RENTED OtNERALUABIUD TY AMAGE[SiE�oea $100,000 CLAIMS•MADE X❑OCCUR MED EXP(Any one Penes) EXCLUDED A Y N 9884084 12/31/2015 12/3112016 PERSONALSADVINJURY S1,000,000 OENERALAOOREOA7E $2,000,000 OEN'LAOOREOATELIMITAPPLIESPER: PRODUCTS-COMPIOPADD $2,000,000 X POLICY dECT LOC AUTOMOBILE LIABILITY fi M D BINDLE LIMIT_ 51,0001000 X ANYAUTO BODILY INJURY(Per renon) ALL OWNED SCHEDULED A AUTOS AUTOS Y N 9884085 12/31/2015 12/3112016 BODILY INJURY(Per sedderlp HIRED AUTOS RON•OWNED ROPE AMAGE AUTOS X UMBRELLA LLAB X occult EACH OCCURRENCE $5,000,000 A EXCESS LIAR CLAIMs•MADE N N 9884087 12/312015 1213112018 AOOREOATE $50001000 DEO I IRETINTION WORKERS COMPENSATION X TORYl1%TU ER AND EMPLOYERS'LIABILITY ANY PROPRIETORIPARTNERIEXECUTNE E.L EACH ACCIDENT $1,000,000 A OFFICERIMEMBEREXCLUDED? NIA N 1 9684066 12/31/2015 12/31/2016 (Mandatoryln NH) E.LDISEASE-EAIMPLOYEE $1,000,000 Ityu.4esarlttle Maar DESCRIPTION Olt OPERATIONS EIIow 11 DISEASE-POLICY UMrr $1,000,0DO OESCRIPTIONOF OPERATIONS I LOCATIONS I VEHICLES IIUOAI ACORD tel.AddtEeeol Remorys SdeddejI mete IPeeo Is regdle4 THE CERTIFICATE HOLDER IS AN ADDITIONAL INSURED SUBJECT TO THE CONDITIONS OF THE ADDITIONAL INSURED BY CONTRACT ENDORSEMENT FOR GENERAL LIABILITY. THE CERTIFICATE HOLDER IS AN ADDITIONAL INSURED SUBJECT TO THE CONDITIONS OF THE ADDITIONAL INSURED BY CONTRACT ENDORSEMENT FOR BUSINESS AUTO LIABILITY. CERTIFICATE HOLDER CANCELLATION 542 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE D(PIRAT(ON DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE 0 1968.2010 ACORD CORPORATION.AN rights reserved. ACORD 2S(2010105) The ACORD name and logo are registered marks of ACORD Massachusetts Department of Public Safety i � tBoard of`Building Regulations and Standards � License:CS-062112 -6onstruction Supervisor `' JOSEPH W VACCARO 18 SUNNYSIDE AVE 1NINTHROP MA 02152 I C:. Expiration: 4 Commissioner 0112312018 • r Office of Consumer Affairs d Business Regulation - 10 Park Plaza.- Suite 5170 Boston, Massachusetts 02116 Home Improvemeat Gontractor Registration Registration: 178137 Type: Supplement Card Expiration: 3/17/2016 NORTHEAST SOLAR SERVICES JOE VACCARO • �== !_ 1 NORTH AVE. �- BURLINGTON, MA 01803 Update Address and return card.Mark reason for change. SCA 1 0 20M-05fii -� Address C) Renewal E] Employment Lost Card �ia�poon�noouu�o�C?/�laasae/zusoltd ice of Consum;r Affairs&Business Regulation License or registration valid for individul use only ME IMPROVEMENT CONTRACTOR before the expiration date. If found return to: Office of Consumer Affairs and Business Regulation WR,egistratio=�E.-j�7&37�; Type: 10 park Plaza-Suite 5170 Expirqlt!oh= p-ZC16'_' Supplement Card Boston,MA 02116 E•� :w : NORTHEAST SOLAR`SEWCES' :. REVOLUSUN JOE VACCARO '' `'' 1 NORTH AVE. BURLINGTON,MA 01803 Undersecretary Not v id without signature t