Miscellaneous - 500 BOXFORD STREET 4/30/2018 (3)
Bic{oRD Id x 1 _ _ _ _ i i DK ENGINEERING ASSOCIATES, INC. Woodland Ridge Phone: (603) 898-8516 47 Enterprise Drive,#7 E-mail:dan@dkengineering.net P.O.Box 4260 www.dkengr.net s s Windham,NH 03087-4260 RECEIVED AUG 18 2016 August 17, 2016 TOWN OF NORTH ANDOVER HEALTH DEPARTMENT Town of North Andover 4�y Health Department 1600 Osgood Street, Suite 2035 North Andover, MA 01845 Attn: Mr. Brian J. LaGrasse, CEHT—Director of Public Health RE: Design Analysis for Siting Subsurface Sewage Disposal System on 500 Boxford Street- Lot 1 & 2 (Map 105C, Lot 42) Dear Mr. LaGrasse: The following discussion intended to illustrate our analysis in siting the proposed subsurface sewage disposal systems and buildings on Lot 1 and 2 at 500 Boxford Street. 310 CMR 15.232 (6), states, "Absorption trenches should be used whenever possible." It is our opinion that alternative systems have their place where absorption trenches are not practical or possible, such as replacement of failed systems. With this in rnind, the houses and septic systems were moved around the lots and resized to accommodate the Title V setbacks and to the maximum extent possible, the North Andover Board of Health and Conservation setbacks. Specifically, Lot 1 The house was designed to accommodate the building setback requirements. As shown, the footprint of the dwelling minus the garage is approximately 1,300 s.f. The septic system was placed at the rear of the building and approximately 63 feet from the wetlands. Moving the septic system to the front of the lot as close to the lot line setbacks as possible, still required a variance for the setback to the wetlands. Another problem is that the building will not fit within the building setbacks as shown on the accompanying sketch. Additionally, construction of the driveway to the building would require work within the Conservation "25 foot no disturb zone". Lot 2 A similar analysis was performed on Lot 2. Moving the septic system in front of the proposed dwelling, would require the house to be set back 44 feet from the front lot line in order to meet the Title V setback requirements. This would move the building within the 50 foot building setback from the wetlands. Also, the system would be within 100 feet of the existing well. However, we were able to move the system closer to the front lot line providing a greater setback from the wetlands of approximately 74 feet. I 41607 Letter re Design Analysis 2016-08-17.docx JN: 41607 Mr. Brian LaGrasse August 17, 2016 Page 2 of 2 I i The septic systems shown on these two lots meet all the requirements of Title V as required. The relief requested is for the setback to the wetlands. We believe the building and septic system configurations provide the least environmental impact to the area. Accompanying this letter, please find the revised Subsurface Sewage Disposal Plan for Lot 2 dated August 17, 2016. As stated above, the system was moved closer to the front lot line to provide more of a separation from the wetlands. Since the system on Lot 1 as shown on the plans dated July 7, 2016 remained the same, the plans were not resubmitted. Should you have any questions regarding the siting of the construction elements of the site, please do not hesitate to contact me. Yours truly, DK ENGINEERING ASSOCIATES,INC. L/cR/vy�G. Daniel Koravos, P.E. President cc: Mr. William MacLeod,Andover Consultants, Inc. DK ENGINEERING ASSOCIATES, INC. )N: 41607 DK ENGINEERING ASSOCIATES, INC. Woodland Ridge Phone: (603) 898-8516 Sim47 Enterprise Drive,#7 E-mail:dan@dkengineering.net P.O.Box 4260 www.dkengr.net Windham,NH 03087-4260 July 7, 2016 RECEIVED Town of North Andover JUL 12 2.016 Health Department TOWN OF NORTH ANDOVER 1600 Osgood Street, Suite 2035 HEA TH DEPARTMENT North Andover, MA 01845 Attn: Mr. Brian J. LaGrasse, CEHT—Director of Public Health �L RE: Subsurface Sewage Disposal System Plan for 500 Boxford Street-Lot 2 (Map 105C,Lot 42) Dear Mr. LaGrasse: The following is in response to the review comment as outlined in your letter dated June 27, 2016: , 1. The existing and proposed lot lines should be depicted on the design plan. On page two of three,please depict the original three lots and overlay the proposed two lots being created with the proposed dwellings,proposed yslems and all lot line setbacks, the 100'wetland buffer done, 50'no build done and 25'no disturbance Zone. Response: Sheet two of three has been updated with the information requested. 2. Indicate why the soil absorption ystem cannot be proposedgreater than 100 feet from the wetland resource area and whyyou cannot comply with section 3.9 of the North Andover Septic Regulations. There is an area in the southwest corner of the proposed lot that is greater than 100 feet from the wetland resource area. Please research alternative designs and site layouts that keep the ystems out of the 100'bu&r done or designs that achieve maximum feasible compliance. Please also note that Section 3.8 of the North Andover Septic Regulations state that a DEP approved device or alternative technology which reduces wastewater to levels below 30 mgt L BOD and 30mgl L TSS can be approved by the department without a hearing before the Board of Health. I have attached a rough sketch that shows 100 linear feet of primary and reserve trenches that are out of the 100'as a rough demonstration. (NA 3.9) Response: The layout of the trenches provided is not feasible. 310 CMR 15.232 (1) states "For all gravity flow distribution systems, a water tight distribution box designed to provide equal distribution of septic tank effluent to the distribution lines of the soil absorption system shall be provided between the septic tank and soil absorption system." With the varying lengths of the trenches as shown on the sketch, the trenches will not receive equal distribution per linear feet of trench. Even if the trenches could be as shown, the house would not meet the required setback from the trenches and building setback from the wetlands. In addition, the trenches are within 100 feet of the existing well within not permitted under Title V. r 41607 Response Letter re Lot 2 SSDS Comments 2016-07-07.docx JN: 41607 Mr. Brian LaGrasse July 7, 2016 Page 2of2 3. The wetland lines have not been confirmed or approved by the North Andover Conservation Commission and may be subject to change.A preliminary site walk by the Conservation Department may be beneficial and reduce additional revisions. Response: The variance requested is required to file with the Conservation Commission. The Notice of Intent filing will verify the wetland lines. 4. On sheet 3 of 3, remove the "untreated building paper"above the peastone layer in the soil absorption ystem. You may change this and use pe 1 meable landscaping fabric. The use of the untreated building paper is not in compliance with Title 5 regulations and will deteriorate rapidly once installed. This does not appear to accomplish the intended outcome stated in your letter dated June 15, 2016. Response: The "untreated building paper" has been removed from the detail. 5. Please submit an additional review fee of$125 with revised plans. Response: The additional fee accompanies this letter. I believe all you concerns have been addressed. Should you have any question or require additional information, please do not hesitate to contact me. Yours truly, DK ENGINEERING ASSOCIATES,INC. (f---Vav�n Daniel Koravos, P.E. President cc: Mr. William MacLeod,Andover Consultants, Inc. i DK ENGINEERING ASSOCIATES, INC. JN: 41607 I p� S�.STL`ED'76y6 • North Andover Health Department (ommunity and Economic Development Division June 27, 2016 Daniel Koravos, P.E. DK Engineering Associates, Inc. 47 Enterprise Drive, #7 P.O. Box 4260 Windham,NH 03087-4260 Re:Subsurface Sewage Disposal System Plan for 500 Boxford Street-Lot 2 (Map 105C,Lot 42) Dear Mr. Koravos, Thero osed wastewaters n stem design plan for the above site dated May 24 2016 Revised on p p Y g p Y > June 15, 2016 and received on June 21, 2016 has been reviewed. Unfortunately, the plan cannot be approved until the following items are corrected. The specific section in Title 5: 310 CMR 15.000, or North Andover regulation that is not met by this design follows each item where applicable. 1. The existing and proposed lot lines should be depicted on the design plan. On page two of three,please depict the original three lots and overlay the proposed two lots being created with the proposed dwellings, proposed systems and all lot line setbacks,the 100' wetland buffer zone, 50' no build zone and 25' no disturbance zone. 2. Indicate why the soil absorption system cannot be proposed greater than 100 feet from the wetland resource area and why you cannot comply with section 3.9 of the North Andover Septic Regulations. There is an area in the southwest corner of the proposed lot that is greater than 100 feet from the wetland resource area. Please research alternative designs and site layouts that keep the systems out of the 100'buffer zone or designs that achieve maximum feasible compliance. Please also note that Section 3.8 of the North Andover Septic Regulations state that a DEP approved device or alternative technology which reduces wastewater to levels below 30 mg/L BOD and 30mg/L TSS can be approved by the department without a hearing before the Board of Health. I have Page 1 of 2 North Andover Health Department, 1600 Osgood Street, Suite 2035, North Andover, MA 01845 Phone: 978.688.9540 Fax: 978.688.8476 attached a rough sketch that shows 100 linear feet of primary and reserve trenches that are out of the 100' as a rough demonstration. (NA 3.9) 3. The wetland lines have not been confirmed or approved by the North Andover Conservation Commission and may be subject to change. A preliminary site walk by the Conservation Department may be beneficial and reduce additional revisions. 4. On sheet 3 of 3,remove the "untreated building paper" above the peastone layer in the soil absorption system. You may change this and use permeable landscaping fabric. The use of the untreated building paper is not in compliance with Title 5 regulations and will deteriorate rapidly once installed. This does not appear to accomplish the intended outcome stated in your letter dated June 15, 2016. 5. Please submit an additional review fee of$125 with revised plans. Please feel free to contact me at 978-688-9540 or Mill River Consulting at 978-282-0014 with any questions you may have. We look forward to working with you to obtain a wastewater treatment and dispersal system which will be in compliance with all regulations and assure protection of public health and the environment of North Andover. Sincerely, / 11 1�41/-,/ - rian J. LaGrasse, CEHT Director of Public Health cc: Michael Donovan Thomas Donovan Cornelius Donovan Andover Consultants, Inc. File Page 2 of 2 North Andover Health Department, 1600 Osgood Street, Suite 2035, North Andover, MA 01845 Phone: 978.688.9540 Fax: 978.688.8476 i(( i. (TO BE �i 28, -' �� �, RAZED) \ 38D APPROX. LOCATION------, 0 OF EXISTING SEPTIC p 22 \ pp SYSTEM (TO BE ABANDONED) 14' ` Lot 1 111 -t DECK ��\ 46' 1 t 1 iv+ i111177111 12, 122.5—;— ► , 40' FG � 'v• PROP. Itt1 �1 IQ r^ 1 ,� D WELLING N 123.5` ` c°w T.F.=131.4 FG PROP. 0' SO t �� ' 7 aj DRIVEWAY }(ON. Z 1 12$ T 1 ;, It + B.F.-123 Al /zzz t ti '� 1 } 1 Jt CLEAR ALL TOP i f '6 t 101.1' 8 t Wr }t jl AND SUBSOIL 11 w , —T FOR 5 FEET ALL - jNi tIto AROUND I <\?\ /, r PRC WAI SER FG f, ,P 123.5 ` r ~ I'FG -------------------------------------------- -- ------ ------------- --- --- E.P. EX. DWELLING .-1`�6 (TQ BE RAZED) BOXFORD STREET ,,.- ' =----- E.P.--------------- ------ ----- ---- w DK ENGINEERING ASSOCIATES INC. Woodland Ridge Phone: (603) 898-8516 47 Enterprise Drive,#7 E-mail:dan@dkengineering.net P.O.Box 4260 www.dkengr.net Windham,NH 03087-4260 June 15, 2016 RECEIVED Town of North Andover JUN 21 2016 Health Department 1600 Osgood Street, Suite 2035 ® (�1 pF NORTH ANDOVER North Andover, MA 01845 �EA[.TH DEPARTMENT Attn: Mr. Brian J. LaGrasse, CEHT—Director of Public Health RE: Subsurface Sewage Disposal System Plan for 500 Boxford Street-Lot 2 (Map 105C,Lot 42) Dear Mr. LaGrasse: The followingis in response to the review comment as outlined in your letter p yo ette dated June 9, 2016: /1. The Assessor's map and lot numbers are not indicated on the design plan (NA 3.2). Response: The Assessor's Map and Lot numbers have been added to the title block and on sheet 2. 2. The existing and proposed lot lines should be depicted on the design plan. ` Response: The existing and proposed lots lines have been added to sheet 2. 3. TI-1-6 was not depicted on the design plan (310 CMA 15.220(4)(h)). Response: TP-6 has been added to the design plan (sheet 1). 4. On sheet 1 of 3, the depths of the test pits and the color of C horitons are incorrect. Response: The discrepancy has been corrected and calculations adjusted. 5. On sheet 1 of 3, the depth of the ESHWT in TI-14 is incorrect. The soil absorption gstem design is based on this elevation and needs to be revised to maintain the 5'separation from the bottom of the trenches to the ESHWT. Response: The discrepancy has been corrected and calculations ad�'usted. / 6. The ercolation test results should indicate a ercolation rate o <2 minsl inch. p p f Response: The less than symbol has been added to the percolation rates. /7. On sheet 1 of 3, the graphical representation of the test pits should be shown as they were excavated instead of circles as depicted in the site plan view. Response: The rectangular test pit symbols have been added to the plan. 41607 Response Letter re Lot 2 SSDS Comments 2016-06-15.docx JN: 41607 I Mr. Brian LaGrasse June 15, 2016 Page 2of3 8. Indicate why the roil absorption ystem cannot be proposed greater than 100 feet from the wetland resource area and maintain compliance with section 3.9 of the North Andover regulation. There is an area in the southwest corner of the proposed lot that isgreater than 100 feet from the wetland resource area. Response: Considering the requited setbacks from the property lines and the requited size of the proposed septic system, the area outside the 100 foot wetland buffer zone in the southwest corner of the lot is insufficient to contain the system. 9. No benchmarks were depicted on the design plan (3 10 CMB 220(4)(8)). Response: A benchmark has been added to the plan and a note stating additional benchmarks will be set prior to construction. / 10. The foundation drain location and elevation were not depicted on the design plan (NA 3.2). •/ Response: The foundation drain has been added to the plan on sheet 1. Also on sheet 1 note 17 was added indicating the setback requirements. 11. Depict the setback distance from the proposed well to abutting soil absorption ystems to ensure compliance with 310 CMR 15.211. Response: The well is existing. To the south of the existing well, a 100 foot offset extends approximately two feet outside of the right-of-way of Boxford Street. The 100 foot offset from the existing well to the north, east and west is totally contained within / the lot. J12. On sheet 1 of 3, the building sewer line proposed will likely need a bend either exiting the dwelling or upon entering the septic tank Please review and propose bends as needed to ensure the inlet tee is located below the manhole access port(3 10 CMB 15.227(1)). Response: The septic tank has been relocated to provide for the pipe from the house to the tank to be perpendicular to both. �13. On sheet 1 of 3, the septic tank appears to be less than 10'to the proposed dwelling(310CMB 15.211). / Response: The septic tank has been relocated. / 14. On sheet 3 of 3, the loading (H-10 or H-20) of the septic tank was not depicted on the design plan (310 CMB 15.226(3)). Response: Note 3 on sheet 3 has been added stating that the septic tank shall meet H10 loading requirements. 15. 6"of crushed stone is required beneath the distribution box(310 CMB 15.221(2)). Response: In the Concrete Distribution Box on sheet 3, note 3 was added stating that 6 inches of crushed store is required beneath the distribution box. 16. On sheet 3 of 3, explain the purpose for the 'untreated building paper" above the peastone layer in the soil absorption s stem. Also explain how the use o the untreated buildin paper is in compliance with Title 5 re ulations. y f gp p p g DK ENGINEERING ASSOCIATES INC. JN: 41607 t '1 Mr. Brian LaGrasse June 15, 2016 Page 3 of 3 Response: The "untreated building paper" is provided to assist in preventing fines from entering the stone trenches and help minimize surface water from inundating the system. I believe all you concerns have been addressed. Should you have any question or require additional information, please do not hesitate to contact me. Yours truly, DK ENGINEERING ASSOCIATES,INC. G Danie �oravos, P.E. President cc: Mr. William MacLeod,Andover Consultants, Inc. DK ENGINEERING ASSOCIATES, INC. JN: 41607 • ��gTG'ED"j�6' • • North Andover Health Department Community and Economic Development Division June 9, 2016 Daniel Koravos, P.E. DK Engineering Associates, Inc. 47 Enterprise Drive, #7 P.O. Box 4260 Windham,NH 03087-4260 Re: Subsurface Sewage Disposal System Plan for 500 Boxford Street-Lot 2 (Map 105C, Lot 42) Dear Mr. Koravos, The proposed wastewater system design plan for the above site dated May 24, 2016 and received on June 1, 2016 has been reviewed. Unfortunately, the plan cannot be approved until the following items are corrected. The specific section in Title 5: 310 CMR 15.000, or North Andover regulation that is not met by this design follows each item where applicable. 1. The Assessor's map and lot numbers are not indicated on the design plan(NA 3.2). 2. The existing and proposed lot lines should be depicted on the design plan. 3. TP-6 was not depicted on the design plan(3 10 CMR 15.220(4)(h)). 4. On sheet 1 of 3, the depths of the test pits and the color of C horizons are incorrect. 5. On sheet 1 of 3,the depth of the ESHWT in TP-4 is incorrect. The soil absorption system design is based on this elevation and needs to be revised to maintain the 5' separation from the bottom of the trenches to the ESHWT. 6. The percolation test results should indicate a percolation rate of<2 mins/inch. 7. On sheet 1 of 3, the graphical representation of the test pits should be shown as they were excavated instead of circles as depicted in the site plan view. 8. Indicate why the soil absorption system cannot be proposed greater than 100 feet from the wetland resource area and maintain compliance with section 3.9 of the North Andover Page 1 of 2 North Andover Health Department, 1600 Osgood Street, Suite 2035, North Andover, MA 01845 Phone: 978.688.9540 Fax: 978.688.8476 regulation. There is an area in the southwest corner of the proposed lot that is greater than 100 feet from the wetland resource area. 9. No benchmarks were depicted on the design plan (310 CMR 220(4)(q)). 10. The foundation drain location and elevation were not depicted on the design plan (NA 3.2). 11. Depict the setback distance from the proposed well to abutting soil absorption systems to ensure compliance with 310 CMR 15.211. 12. On sheet 1 of 3,the building sewer line proposed will likely need a bend either exiting the dwelling or upon entering the septic tank. Please review and propose bends as needed to ensure the inlet tee is located below the manhole access port (3 10 CMR 15.227(1)). 13. On sheet 1 of 3,the septic tank appears to be less than 10' to the proposed dwelling (3 10 CMR 15.211). 14. On sheet 3 of 3,the loading (H-10 or H-20) of the septic tank was not depicted on the design plan (3 10 CMR 15.226(3)). 15. 6" of crushed stone is required beneath the distribution box (3 10 CMR 15.221(2)). 16. On sheet 3 of 3, explain the purpose for the "untreated building paper" above the peastone layer in the soil absorption system. Also explain how the use of the untreated building paper is in compliance with Title 5 regulations. Please feel free to contact the office or Mill River Consulting at 978-282-0014 with any questions you may have. We look forward to working with you to obtain a wastewater treatment and dispersal system which will be in compliance with all regulations and assure protection of public health and the environment of North Andover. Sincerely, B ian J. LaGrasse, CEHT Director of Public Health cc: Michael Donovan Thomas Donovan Cornelius Donovan Andover Consultants, Inc. File Page 2 of 2 North Andover Health Department, 1600 Osgood Street, Suite 2035, North Andover, MA 01845 Phone: 978.688.9540 Fax: 978.688.8476 andover 1 East River Place consultants Methuen, Massachusetts 01844 inc. Tel. (978) 687-3828 Fax (978) 686-5100 www.andoverconsultants.com May 31, 2016 Town of North Andover Board of Health 1600 Osgood St. North Andover, MA 01845 RE: Request for Variance Lot 1 and Lot 2 at 500 Boxford St. North Andover, Mass. Dear Members of the Board: This office represents the three individual owners of three lots at and adjacent to 500 Boxford Street. The owners are listed below: Michael Donovan RECEWED 12 Johnson Street J00 ,11 North Andover, MA 01845LU16 TOWN CF NORTH ANDOVER Thomas Donovan HEALTH DEPARTMENT 5000 Wheatridge Drive Fuquay-Varina, NC 27526 1�— Cornelius J. Donovan 12 Trolley Car Lane Londonderry, NH 03053 The property in question has been in the Donovan family since 1946, when Cornelius and Catherine Donovan, parents of the current owners, purchased this site containing 5.24 Acres, more or less. In December of 1970, Catherine Donovan hired Stowers Associates to survey the land and subdivide it into 4 lots. The subdivision plan was endorsed by the Planning Board on April 4, 1977 and recorded at the Registry of Deeds on April 8, 1977. The plan showed Lots A, B, C and D and a copy of the plan is attached. Bill/Letters/Town of North Andover—500Boxford.doc Civil Engineers • Land Surveyors 9 Land Planners andover consultants inc. Page 2 Town of North Andover On January 5, 1992, Catherine Donovan conveyed the lots to her children. Her daughter, Kathleen Garon, was deeded Lot A. Her sons, Michael Donovan, Thomas Donovan and Cornelius Donovan were deeded Lots B, C and D respectively. Each child had expectations of building a house on each of the lots. In fact, Kathleen built a house on Lot A. Over the years, since the land was subdivided in 1970, regulations have changed and become more restrictive. It is now impossible for any of the three brothers to build on their lot, primarily due to the North Andover Minimum Requirements for Onsite Wastewater Disposal Systems. Michael, Thomas and Cornelius Donovan are proposing to reconfigure their three individually owned lots into two new lots. Based on this new configuration we have completed percolation tests and test pits for the two lots and have designed subsurface sewage disposal systems. The designs comply with all of the requirements of Title 5 and also comply with the North Andover Minimum Requirements with the exception of the distance to a wetland resource area. Title 5 requires a 50 ft. setback from a wetland, for which we comply, but North Andover requires 100 ft. It is this section of the regulations that we request a variance. The applicants believe they qualify as seriously aggrieved parties and are eligible for a variance. Enforcement of the setback distance provisions in the local requirements would be manifestly unjust since it would render lot B, owned by Michael Donovan, and lot D, owned by Cornelius Donovan unbuildable. Lot C contains an abandoned dwelling and is owned by Thomas Donovan. Testing has been completed for two newly configured lots. During our field surveys and testing no soils or site conditions were noted that would be unique to the Town of North Andover. The conditions observe I� dare similar to those we have seen in surrounding towns in the Merrimack Valley. Two systems have been designed to comply with Title 5 and all of the provisions of the North Andover Requirements with the exception of the distance to wetlands. On lot 1 we can provide 63 ft. and on lot 2 we can provide 65 ft. Enforcement of the 100 ft. setback distance would render lots B and D unbuildable and deprive Michael Donovan and Cornelius Donovan of all beneficial use of their property. i andover consultants inc. Page 3 Town of North Andover By allowing the variance, the brothers can eliminate the existing abandoned house and it ancient septic system and only two dwellings will be built, with modern sewage disposal systems. We appreciate the consideration of the board in this variance request. Sincerely, ANDOVER CONSULTANTS I C. William S. MacLeod, P.E., P.L.S. President WSM/an 0r7— pgy° /�L �7N p� LANO NORTH ANpOVER, MASS. t- � Scab 1°•i/Osrovs.os Fssocigrrs r.+c. Rrc. tq>..n Su or+s OECE HBER /97D MEr..•r�r N, Mgss.v 3 MpRcr, /9Yy 0 9 O 5 HO O SO ioo 5'O P Ado , pian M,>vP w Ru ley �� pr,a pr°O viq r,e sis er r"rr Rrc,srrc vs o/ ordns r >uur Ce.,ne�vrp.r✓ i O R lq 5 PLANNING°01:0 n CONiROt ArML ' [ � O PLANNING 6CAiJ - '- J. Do 4 G o 4by pp d4 °.53Po SIC) CCT:.'., SOAR[i 1'--... . I. Qf J5 1.SSS r S° 5 ARIA* N m lar C m �a ARIa= •!G,030 ¢' o Ns ... - ARRA• yr 7i'O o � '.av' q99 / / N J'9' SY 2io-OW \t---F - 225.00 S/Q./2.yQ.1✓�.'ONlr CNP R1 orT 2 4 � 0 Qa'�a e Bo List of Abutters for Notification of Hearing before the North Andover Board of Health for a variance on 2 lots at 500 Boxford Street. (This list is a consolidation of 3 lists certified by the Assessor, eliminating duplicates and the applicants.) Page 1 of 2 MAP LOT# Name&Address 105.C/5 Brett Rodden 10 Duncan Drive North Andover, MA 01845 104.B/19 Seon Tae Jeong 50 Duncan Drive North Andover, MA 01845 104.B/56 Karen Mello 40 Duncan Drive North Andover, MA 01845 104.B/139 George Adams 1634 Salem Street North Andover, MA 01845 104.B/171 Paul Schmitt 28 Duncan Drive North Andover, MA 01845 104.B/174 Gary Wieman 88 Duncan Drive North Andover, MA 01845 104.B/188 Edward McGetrick 89 Duncan Drive North Andover, MA 01845 104.B/189 Paul Rabbit 75 Duncan Drive North Andover, MA 01845 105.C/9 &49 Elsie Pouliot 465 Boxford Street North Andover, MA 01845 List of Abutters for Notification of Hearing before the North Andover Board of Health for a variance on 2 lots at 500 Boxford Street. (This list is a consolidation of 3 lists certified by the Assessor, eliminating duplicates and the applicants.) Page 2 of 2 MAP LOT# Name&Address 105.C/22 Messina Development Co. Inc. 277 Washington Street Groveland, MA 01834 105.C/25 Lauren Cramer 537 Boxford Street North Andover, MA 01845 105.C/40 Linda Dean 7 Duncan Drive North Andover, MA 01845 105.C/80 Michelle Pouliot 525 Boxford Street North Andover, MA 01845 105.C/82 S&L Homes LLC 10-1 Middlesex Avenue Wilmington, MA 01887 105.C/26 Alexandre Klimenko 545 Boxford Street North Andover, MA 01845 105.C/27 Justin Motta 577 Boxford Street North Andover, MA 01845 Abutter to Abutter( ) Building Dept. ( ) Conservation ( ) Zoning If ) Town of North Andover Abutters Listing REQUIREMENT. MGL 40A,Section 11 states in part"Parties in Interest as used in this chapter shall mean the petitioner, abutters,owners of land directly oppositeon any public or private way,and abutters to abutters within three hundred(300)feet of the property line of the petitioner as they appear on the most recent applicable tax list,not withstanding that the land of any such owner is located in another city or town,the planning board of the city or town,and the planning board of every abutting city or town." Subiect Property: MAP PARCEL Name Address 105.0 41 Michael Donovan 12 Johnson Street,North Andover,MA 01845 Abutters Properties (Boxford Street) Map Parcel Name Address 104.6 19 Seon Tae Jeong 50 Duncan Drive,North Andover,MA 01845 104.8 56 Karen Mello 40 Duncan Drive,North Andover,MA 01845 104.B 139 George Adams 1634 Salem Street,North Andover,MA 01845 104.6 171 Paul Schmitt 28 Duncan Drive,North Andover,MA 01845 104.B 174 Gary Wieman 88 Duncan Drive,North Andover,MA 01845 104.6 189 Paul Rabbitt 75 Duncan Drive,North Andover,MA 01845 105.0 5 Brett Rodden 10 Duncan Drive,North Andover,MA 01845 105.0 9&49 Elsie Pouliot 465 Boxford Street,North Andover,MA 01845 105.0 22 Messina Development Co.lnc 277 Washington Street,Groveland,MA 01834 105.0 40 Linda Dean 7 Duncan Drive,North Andover,MA 01845 105.0 42 Thomas Donovan 5000 Wheatridge Drive,Fuquay-Varina,NC 27526 105.0 43 Cornelius Donovan 12 Trolly Car Lane,Londonderry,NH 03053 105.0 80 Michelle Pouliot 525 Boxford Street,North Andover,MA 01845 105.0 82 S&L Homes LLC 10-1 Middlesex Avenue,Wilmington,MA 01887 This certifies that the names appearing on records of the Assessofrp ce as of -l� Certifier Date -5- a%� Abutter to Abutter( ) Building Dept. ( ) Conservation ( ) Zoning ( 1 Town of North Andover Abutters Listing REQUIREMENT: MGI-40A,Section 11 states in part"Parties in Interest as used in this chapter shall mean the petitioner, abutters,owners of land directly oppositeon any public or private way,and abutters to abutters within three hundred(300)feet of the property line of the petitioner as they appear on the most recent applicable tax list,not withstanding that the land of any such owner is located in another city or town,the planning board of the city or town,and the planning board of every abutting city or town." Subiect Property: MAP PARCEL Name Address 105.0 42 Thomas Donovan 5000 Wheatridge Drive,Fuquay-Varina,NC 27526 Abutters Properties (Boxford Street) Map Parcel Name Address 104.6 19 Seon Tae Jeong 50 Duncan Drive,North Andover,MA 01845 104.6 56 Karen Mello 40 Duncan Drive,North Andover,MA 01845 104.6 139 George Adams 1634 Salem Street,North Andover,MA 01845 104.6 171 Paul Schmitt 28 Duncan Drive,North Andover,MA 01845 104.6 174 Gary Wieman 88 Duncan Drive,North Andover,MA 01845 104.6 188 Edward McGetrick 89 Duncan Drive,North Andover,MA 01845 104.6 189 Paul Rabbitt 75 Duncan Drive,North Andover,MA 01845 105.0 9&49 Elsie Pouliot 465 Boxford Street,North Andover,MA 01845 105.0 22 Messina Development Co.lnc 277 Washington Street,Groveland,MA 01834 105.0 25 Lauren Cramer 537 Boxford Street,North Andover,MA 01845 105.0 40 Linda Dean 7 Duncan Drive,North Andover,MA 01845 105.0 41 Michael Donovan 12 Johnson Street,North Andover,MA 01845 105.0 43 Cornelius Donovan 12 Trolly Car Lane,Londonderry,NH 03053 105.0 80 Michelle Pouliot 525 Boxford Street,North Andover, MA 01845 105.0 82 S&L Homes LLC 10-1 Middlesex Avenue,Wilmington,MA 01887 This certifies that the name app aring on record.s Of the SSe rs 4d Of Certified b , _ .._ ,Cute �� Abutter to Abutter( ) Building Dept. ( ) Conservation ( ) Zoning ( ) Town of North Andover Abutters Listing REQUIREMENT: MGL 40A,Section 11 states in part"Parties in Interest as used in this chapter shall mean the petitioner, abutters,owners of land directly oppositeon any public or private way,and abutters to abutters within three hundred(300)feet of the property line of the petitioner as they appear on the most recent applicable tax list,not withstanding that the land of any such owner is located in another city or town,the planning board of the city or town,and the planning board of every abutting city or town." Subiect Property: MAP PARCEL Name Address 105.0 43 Cornelius Donovan 12 Trolly Car Lane,Londonderry,NH 03053 Abutters Properties (Boxford Street) Map Parcel Name Address 104.13 189 Paul Rabbitt 75 Duncan Drive,North Andover,MA 01845 105.0 9 Elsie Pouliot 465 Boxford Street,North Andover,MA 01845 105.0 22 Messina Development Co.lnc 277 Washington Street,Groveland,MA 01834 105.0 25 Lauren Cramer 537 Boxford Street,North Andover,MA 01845 105.0 26 Alexandre Klimenko 545 Boxford Street,North Andover,MA 01845 105.0 27 Justin Motta 577 Boxford Street,North Andover,MA 01845 105.0 40 Linda Dean 7 Duncan Drive,North Andover,MA 01845 105.0 41 Michael Donovan 12 Johnson Street,North Andover,MA 01845 105.0 22 Tohmas Donovan 5000 Wheatridge Drive,Fuquay-Varina,NC 27526 105.0 80 Michelle Pouliot 525 Boxford Street,North Andover,MA 01845 105.0 82 S&L Homes LLC 10-1 Middlesex Avenue,Wilmington,MA 01887 105.0 83 James Santoianni 550 Boxford Street,North Andover,MA 01845 This certifies that the naMOU ParinG On WW records of the A ess as of gate 2 /6 Certified b TOWN OF NORTH ANDOVER 3u > Office of COMMUNITY DEVELOPMENT AND SERVICES HEALTH DEPARTMENT 1600 OSGOOD STREET; SUITE 2035 NORTH ANDOVER, MASSACHUSETTS 01845 978.688.9540- Phone 978.688.8476-FAX E-MAIL: healthdept@northandoverma.gov WEBSITE: http:/�`www.northandovermagov SEPTIC PLAN SUBMITTAL FORM Date of Submission: Site Location: Engineer: C l-► / ,CJ�'� /,v �„� New Plans? st Yes / 275 2 $ /Plan Check# � (includes 1 submission and one re- review only) Revised Plans?Yes $125/Plan Check# Site Evaluation Forms Included? Yes 4'000"' No RECEIVED JUN 0 " 2016 Local Upgrade Form Included? Yes No TOWN OF NORTHANDp ,3/c L .t fifc LCDV HEALTH DEPARTMENT Telephone#: 9'7T-!r$7 -,3 0 2 8 Fax #: � I� E-mail: �45"92-4 4? ls`:'�+ � �146 r/ SDS . lcle7- Homeowner Name: /'�J/� �E� �!>4/4/11 Gt vt o� ,�,+ �lr de s-s OFFICE USE ONLY When the submission is complete (including check): Date stamp plans and letter Complete and attach Receipt ➢ Copy File; Forward to Consultant ➢ Enter on Log Sheet and Database � r Commonwealth of Massachusetts City/Town of North Andover. Percolation Test Form 12 Percolation test results must be.submitted with the Soil Suitability.Assessment for On-site Sewage. Disposal: DEPhas provided this.form:W use by local Boards.of Health.. other forms maybe used but .the information must be substantially the same as that provided here, Before using this f©rm. check with the local Board.of Health to determine the form they,use. fiNing,aut forms tmng,out `"`'1e" A. Site Information i on the computer;. Jse.only the tats Michael Donovan Thomas&CatherinB Donovan, key to move your Owner Nato cursor=do not 500 Boxford Street,Map 10SC Lots41 &42 5'!x/3 D Lv?" use the return key: Street Addreett or Lot "7Ii1 North Andover MA Q1845 �--� C'�'Ffown: State Zip Code Contact Person(if different from.Owner): Telephone Number B Test Res u Its 1212f15 1110,0 an 1212115 11:00 a:m_ Date_ Time Date Time _ _.._ _ Observation Hole# Pere Perc 4-- - _ depth.of Perc: 50" ,� Start Pre-Soak 1t:45 12:29'_'_.___ End Pte-Soak 12`00 12.44.. Time at 12:" --2:Oa _�_ _. ___ 12:44 Time at V 12:04 . . 12:46_ Time at 6° ...: 12:48- Time(9"-6"); 4 Minn 2 Mlns Rate:.(Min./inch) <2 MiftAnch a Z.Miit.11nch Test Passed; Test Passed; Test Failed.- ❑ Test Failed; El I Steve Eriksen. Tegt Performed By: -spat.ROwe-North Andover Board of Health: _._ Baartt of Healih Witnose _ Comments., t5form12.doc•08.115 Perc Test•Page 1 of 1 Commons ealth:of.Massachusetts Cltyfrown of Noah Andover .Form 11 - Sgit Suitability Assessment:for. On-Site. Sewage Disposal A. Fa0lcty Information Thomas& Catherine Donovan Owner Name 500 Boxford Road ,Lot 42 Add Street Ad - T,... . Map1wro North.Andover Ma, 0184.5 Ply -- State Zip Code B. Site Information 1. (Check one) New Construc#on. L�:alpgrade [] Repair 2. Soil Survey.Available? 0 Yes: CI :No If yes: Web Soil.Survey 2538 Scuroe $pit A11ap Uru! Hinckley Loamy.Sand .Slope& Draughtiness Soil Name Sal Lmaations _Glacial Outwash Outwash Plain. Geologic/Parent Material Landform 3.1. Surficral CGeological.Report;Ava fable?:[] ye4 ®:No if yes: _ Y%ar Publ44eW-50tace Publication Scale -map,wrilt a. Flood Rate`lnsurance.Map Above the 500-year-flood boundary? Yes ❑ No Within;the.100-year:flood'boundary? [] Yes. NQ Yes,continueao fib: 5.. Within a velocity.zona? (� Yes. No & Within.a<Ma.pped Wetland.Area? M44SOIS Wetlan.O Data Layer.: Q Yes � No _.._ W004 Type. 7. Current Water Resource C-ondttions(USES): 1211.5 Range: ] Above Normal Normal Relow Normal MontNY.ear 6. Other references reviewed: t5formt 1 test 3 and,4•rev:811.5 Form 1.1—1501:44444 A*#ownent W., n, toSowag-Disposal •Paq�1 of.8 T Commonwealth of Massachusetts. CitylTown of North Andover Form 11 Soil $:u tabili A'ss $*nnnt for On...-Site Sewage Disposal C. On-Site Review (minimum:of two holes required at every:proposed l#nkq y and resanca disposal oreq) Deep Observation:Hole Number: DH-3 12015 11:00 am., Rain, Qatg Tirne� weather .. . . _ T. Location GrpuncJ Elevation:at Surface of Hole: See Plan Latitudell.ongitude 42:4Q 04N ./ 71:03 0 68W. feet Description of Location: Existing.single-family lot: shown on the plan as Lot 2 Test;:3 2. Land Use Cleared backyard area fag.woodland,:agncultura(,fieIcL —W—vacetc:). None 0-3% Sufiro 5�ones{a_g,.copbi�;$tongcbppltt�tf;4ic.} �op�{94) Grass rubus and multiflora rose Outwasft-plain Toeslope V�atatton tandfoml P..osiUon ofi.,�a<tS41. I' 3. Distances from: Open•1aterBody ?50 ft. �BS.FS* TS) gWy >50t Uads 0feet fe . ' few property Line >10 ft Dc1n. In Water Well > 1 Other f � feet. 4. Parent Material. Glacial eet fes''Outwash Unsuitable Materials present: ❑ Yes No 1 If Yes: ❑ Disturbed Soil ❑ Fig Material ❑ Impervious Layer(s) [] VYeathradlFracturedRock CJ 500rock; 5. Groundwattrr Observed_ ❑ 'Yes Depth V1lpi09 foam Fit D Estimated Depth,tq Hi9h.Groun0water 73" c3pth Staltding WOW in Iola, inches elevation Worm 11 test Sand d rev.&95 Four1.1 t soil.$uitabil' ttY:Asset€rrwnt,fgr Onto:Sewa�@ Di�pgsal *.Page>2 of I _ I Commonwealth of Massachusetts_ CityTTown of North Andover k Form, 11. - $9. 11 Suitability Ass ssm of for On-Site _-Wags Q sposai C. On-Sita Review(continues) Deep Observab.on Hole N4m0er DH-3 . tisoximorhic Features C =eDepth00 Sail HcriroM.Sod Matrix:Color. awl Texture y i Layer JUSDA►, .004tructure Consistence; Other Depth Cob4ie¢,. Color Percent Gavel {Haat! Atones AP 10.,yr212 FS4 evanulat Friable BW 10 yr414. FS.LeakBlocky Friable 18-84Med-Coarse, a ' C1 2.5y 514: 73" T5`yr:616, 15 0: S ?JQ On&Grt i,n, Lo de i i Additional:Notes, t5forrnt l test 3 ano:4•_reV.:8/15 Form 11 SaikSuitabiGtk.AssegsrnetitfQrQn Sid S..e+�age Dispogal •Paige a cf 8 Commonwealth of Ms*e achu* City/Town Of Notth Andover Form 11 - Soil;S.uitability Assessment for On-Site $eyyra.94. Disposal C, On-Site Review (continued 040P Observation Hole-Number.: DH-4, 12/2115 Y1:OO am. Rain `. Date Time Weather 1. Location, GrQPnd.Elevation at Surface.of Hole. See Plan Latitude/Ldude; het qn 9 42:40 04 N t.'7103 068 W 2. Land Use Cleared backyard area. None (e.9•.wa4dland,agciculWrarfiald,vacant.iQt etc f: 0-3% -%4d4 @ Wines(Q•�.,cobbles stones;bould �qac &IpPa c'�I: Grass, Tubus and:multiflora rose Qutwash plain Taeslope vegetation... . tan�tortn _ 3. Distances.from: Open Water Body �.50.ft. D +nae > +n' l.aAclscsaRe-GSU,sH',H.%FS, teen 1Nay 50 ft. Wetlands >50 ft. � feet j property Line >.101L Drinking Water Welf , 10 _ (Jtktar' feee Feet f _ 4.. Parent.Material: Glacial outwasb Unsuitablevatedais:Present, [Q Yes No If Yes_ [] Disturbed`Soil. 0 FSI Material L7 Impenlious l.ager(s) We_-Oer_edlFraqurscl;R4okC7 4edracic 5: Groundwater Odserved::. [] Yes, NQ if yes; 6;plh Weep'n front p p Estimated Depth to High Groundwater .78, eetn Stangln9•Water in Hole inches elevation i t5form.l l:test 3 and 4•rev.8115 Form 11 Solt S4bbi ity Assessment for Qn-Sitp, ge Disposal -Page 4 of 8 Commonwealth of Marsachusstts City/Townof North Andoy.or Firm 1111 - Soil. i litability Assessment for On-Si�0.�Q�+ra0a Di POsal C. On-Site Rqv w (contin iad} Deep Qbse.rvation:Hote N.umber' DH-4 Radoximarphic FeaturespoarmEra amen Depth(in;) soil Hori;w Soil matrix.Golor• Soii Text4m, byVoWma: Soil —�..-. L ager ifipuit,(iiAunselt►. l :SuuGflua` Canslstai►Ge ather pth Color orcent (USDA obbles zfzR4nes 0-8" Ap 10 yr 212 FSL GranulaF Fria��e Sw 10 yr 414 FSL Weak 41ockcy Friabifa 18-90" G1 2:5y5/4. 79,: 7..5yr 616 GS& 30'Yo Single'Grain Loose Stratified 1 't Additional Notes: t5form1 l test 3 anci A rev:a15 Form 11:--Soil Suitability Assessment for Ott,S4ta Sewage pispospi •psgq 5 of$ Commonwealth of Massachusetts. City/town of North Andover. - Form 11 - S U SUU40ity Assess:ment for On-Site S Wade Disposal D. Determination of High Groundwater Elevation 1, Method Used Qt?s HOIe:_{ DH-3 la04; He1e#AH-4 D Depth observed standing water in 9b4ervation hole, ipches inches: ❑ Depth.weeping;fromside of observation,hole Inches Inches:. Dept!~to-soil:redoximorphic features (.mottles) 73 78 ! inches; ! ❑ Depth to adjusted seasanaI.higb groWpdwate..r (USps", ho:dolagY) Inches ,riches' Index•Wg�Nurntae — Reading Qate Sh=Sq—.IS,x(OW. OW'W)tP Nrj Qbs..Hole# S'. sr QWC ...._ QwnW Owr Sri Obs. Hole# Sc. Sr O.We own= OW: Sn E. Depth of Pervious Material; 1. Deptti of Naturally Occurring PerviousMateriai a. Does at least four feet of,naturally occurring pervious material exist in all areas observed thmughout:the,area proposed for the soil absorption system? Z Yes [] No b. If yes,at what,depth was�t observed? UPRer b4uindary;, 18" Lower;bpundary: BA" inches inches c. if no, at�whatdepth.was.impervious inaterial.observed? Upperboundary: Lowerbour.Wary: inches Inches. Wormi 1 test 3 and 4•rer.$/15 F4.m —$oil Su . 11 ¢ably:Assessment fcr.Qn•Site,•Sgwaae;Disposal Paga 6 oP8 Commonwealth of"Massachusetts. City/Town of North Andover' Form I I - Soil SuitabilityAsssssrnant for Qn-StateS�wa,9 Disposal nS C. On-Site. Review (continued) Deep Observation Hole,Number: DH-6 .1212/15 11.:00a.m. Rain Date Time, Weather 1.. Location Ground Elevabon.at Surface of Hole: between test Latitude/Longitude:. 42'40'114"N, / 71'02' 0.68"W 3 and 4 2: Land Use Cleared backyard area . ,None 0-3% (e.g.,`woodland,.e9riculturaifieki,vacant io,:etc.) Srurface:Stones te.g,cobbles,stones,boulders.etc,): Sopa(Yoj Grass, rubus:and multiflora rose Outwash Plain Toesoe, vegetation w. iarorr►, . _. Posmw an L3r�1> ataacsu sN,as,M 3. Distances from Open Water Body > 50 ft Drainage Way >50 ft. Wetlands >604t feet- fQet feat, Property Line, > 1.0 ft Drinking WaterWeil > 10t1 ft Other feet feet".. . feat 4. Parent Material: Glacial`Outwash Unsuitable Materials Pre$ent: [] Yes No If Yes: ❑ Disturbed Soil. (] Fill Material. ❑ Impervious Layers) Q WeatheredLFractured.Rock (] Bedrock 5,. Groundwater Observed:, Yes []. No; If,yes: Depth'Weeping.fromPit Depth Standing.Water in Hole Estimated Depth to.High.Groundwater: 90- inches, elevation 45forrntl.test 5 and 6-re 8115 Foan'1 t.-Soit Subbilty.Assessmeafor on.Site Sawage.Disposal...page.4 cf•a Commonwealth of Massachusetts City/TQwn of North Andover Form. 11 - Soii Suitability Assessment for On-Site Sewage Qi$ osa[ C. On-SKe Review (continued) Deep.Observation Hole Number:. DH-6 Redoximorptuc Features Coarse Fragments Depth(in.) Soy Horizory.soil Matrix.Col Pr• Sgil:Texture.; �°by Volume Soil i i-aYQr Moist(Munsell) S:t>it.Sk�wwre:.conslrtonce Other D,ep (USDA} th, Co19,r ef�nt Cavell, es (Hard 0-81' Ap 10 yr.2/2 FSL Grartyiar Friable. 8-18" Bw 10 yr 4/4 i=SL Weak Blocky Friable 18-11050 C1 2,5y 514 go." 7.5yr 6/6 15% GS&G 3o°/a 150k Single grain Loose i Additional Notes: t5form 11'test 5 and 6•rev.8/15 Form 11—Soil Suitab�lRy Assessrt�s}�t:fot on Sife Swage D�Sppsal •Page 5_of 8 Commonwealth.of Massachusetts r Cityfrown of North Andover _ Form 11 - Soil Suitability Assessment.for On-Site $gwaqe D D. Determination of Hiq.h Groundwater Wavat on. 1.. Method Used. Ohs. Hole# H- Q-� obs,NglrY#DH-6 Depth observed standing water in observation hole ,nches �� ® Depth weeping from side:gfobsryation hie 80" inches u►chas ®: Depth t4 soil redoximorphic.features_ (mottles) 54" „ ulchos Q Depth to adjusted seasonal high,groundwater(S„) (USGS methodology) inks inches Inclax..well.Number _ Reaping,eta Sn=Sc—(Sr X(Q1Nr-QWM'UY0.Wrj Obs. Hale# Sc Sr OW'c oWm'" owr. Sa 00§. Hole,# Sc Sr Owl ow. QWr Sp E. Depth of Pervious Material 1. Depth of Naturally occuxring,.PeCYiaus Mateciall. a: Does at least four feet of naturally occurring pervious material exist in all areas observed throughout the area prpp944 for the ugil absorption system? 12 Yes ❑ No b. If y@§, at what depth was it 04sarved? Upper baupgwy. 18:' Lower boundary; 105" �oFtwc o- If no,at what depth was impervious:Material.Qbsaryed? Upper boundary: Lowerboundary: 00" lnrhas inches t5formi�test 5 and 6•rev.811.5 Fommr 11 ►ataldy.A65@S¢li►erK for 9".9 SQws9a aispospl Rage 6 8 Commonwealth of Massachusetts _ C4frown of North Andover Form 11 - Soil Suitability sesIma_nt for On-Site.:So-cage Disposw F. Board of Health Witness lssac Rowe North Andover . Name of Board Pf""Ith Witne*-* wwd of I G. Soil Evaluator Certifigeton I certify that i am currently approved 4y the Depen Ment of Environmental:ProtectlRn laurauaat to 310 CMR 15.0.17 to conduct soil evaluations and Mgt the above> talysis has b>aen p�atfiormecl.by me cansiatenYvh ttt+e r4Hrd°tridtFlln�,expertise and�xReaance described in MR 3�0 C1�017_ 'I furkhercerkify tttat.ttfe rasults of"my sal"evan,a$lntcatejl.in'tktQ; aohe¢<So�I:Exaluatian Fcurn, are,aceurate and in accArdanca wtth' 1,0 l✓MR 15.100 thtYwgh 15,1,0.3: 1.2/3/15 Signature or:. at Fvaluator Date Steven Eriksen W0/16 Typed or Printed Name of soil:Evaluator 1 Licw t"A Expiration Date of Liw Note:,ln accordance with_310 CMR tS..Qt a(2?.ttus forrtl,must be stab.muted to:the eiPP(OYinQ autW(Ity wiih►rt t days of ow 0"of testing,and to the designer and the,property owner with•Percalation Tess Form:12. t.5lcrm 11 test 5 and 6•ray.8115 Farm 11—Spil$ui tabiWy:Aacess ent(cr.Qa Site Smirage Dlspgsal •NGa 7 of 8 � _ Commonwealth of Massachusetts City/Town of North Andover ' Y Farm 11 Sail. Suitability Assessment torOn-.S to Sewage: Disposal Field Diagrams Ilse this sheet for field diagfams:. t5form11 test 3 and d•row.8/15. Form 11—49ii,S40404. !tY Assessment for Qn-Stt@ Sewage P40541. No a 0f 8 Hadge, Lisa From• Isaac Rowe <irowe@millriverconsulting.com> Sent: Wednesday, December 02, 2015 3:14 PM To• Hadge, Lisa; 'Pam Lally' Cc• Grant, Michele;Isaac Rowe Subject: RE: 500 Boxford Attachments: 500 Boxford St(2 lots) - Soil testing results 12-2-15.PDF Lisa/Michele, Attached are the soil testing results for the above referenced property. Your office should confirm the applicant has paid the correct fee for(2) new construction lots.The application indicates an addition to the existing dwelling.The soil evaluator, Steve Erickson, indicated we were testing for (2) new lots. MRC will be invoicing appropriately. These projects will likely be seeking variances from the BOH regulations to site a leaching facility less than 100'to a BVW for new construction. Please let me know if you have any questions. Thanks, Isaac M. Rowe, R.S. Project Manager Mill River Consulting 6 Sargent Street Gloucester, MA 01930-2719 Phone: 978-282-0014 ext.804 Fax:978-282-1318 irowe@miliriverconsulting.com www.miI[riverconsulting.com -----Original Message----- From: Hadge, Lisa [ma iIto:Ihadge@townofnorthandover.com] l Sent:Tuesday, November 17, 2015 9:32 AM To: Dan Ottenheimer; Isaac Rowe; Pam Lally Cc: Grant, Michele Subject: 500 Boxford Good Morning, Andover Consultants are taking this off hold. I am sending the applications to you again. Please read the attached email from Jen Hughes of Conservation. I will have Heidi from Conservation update the Application for Soil Testing when she gets back in the office. Please call Norse Environmental, either Steve Ericson or Maureen Herald (both certified soil evaluators) at 978-649-9932 to set up the soil testing.Thanks. -----Original Message----- From: noreply@townofnorthandover.com [m aiIto:noreply townofnorthandover.com] 1 : Z 3 �' J — - I ; 7 Q/=o7 ! X14 Q dl 1= .r • � it ! i ° i - ' ---- - -- --- --------- coi tI ' IT" 'VL n - ` TOWN OF NORTH ANDOVER Office of COMMUNITY DEVELOPMENT AND SERVICES HEALTH DEPARTMENT 1600 OSGOOD STREET; SUITE 2035 NORTH ANDOVER,MASSACHUSETTS 01845 RE Susan Y.Sawyer,RENS,RS 978.688.9540—PhoneAAUG 13 2015 y Public Health Director 978.688.8476—FAX healthdept(a)townofnorthayerr.9om . M)RTH ANDOVE �(�� fn�handover.co �;Ri Mw (In 20n5U APPLICATION FOR SOIL TESTS DATE: August 3,2015 MAP&PARCEL: 105C 42 LOCATION OF SOIL TESTS: 135'northwest of existing dwelling(see sketch) �w ' rL OWNER: Thomas Donovan Contact#: APPLICANT. Andover Consultants,Inc Contact#: 978-687-3828 ADDRESS: 1 East River Place,Methuen,MA 01844 ENGINEER: Andover Consultants,Inc Contact#: 978-687-3828 CERTIFIED SOIL EVALUATOR: James Fairweather �Kg wl r� Ys�' UI r{)nw.r, (i RlE�lc Intended Use of Land: Residential Subdivision Single Family Home Commercial Is This: Repair Testing: Undeveloped Lot Testing: ✓ Upgrade for Addition: In the Lake Cochichewick Watershed? Yes No ✓ l Q THE FOLLOWING MUST BE INCLUDED WITH THIS FORM ➢ Proof of land ownership(Tax bill,or letter from owner permitting test) ➢ 8.5"x 11"Plot plan&Location of Testing(please indicate test nit sites on the plan) ➢ Fee of$425.00 per lot for new construction. This covers the minimum two deep holes and two percolation tests required for each disposal area. Fee of$360.00 per lot for repairs or upgrades. GENERAL INFORMATION ➢ Only Certified Soil Evaluators may perform deep hole inspections. ➢ Only Mass.Registered Sanitarians and Professional Engineers can design septic plans. ➢ At least two deep holes and two percolation tests are required for each septic system disposal area. ➢ Repairs require at least two deep holes and at least one percolation test,at the discretion of the BOH representative. ➢ Full payment will be required for all additional tests within two weeks of testing. ➢ Within 45 days of testing,a scaled plan(no smaller than 1"-100')shall be submitted to the Board of Health showing the location of all tests(including aborted tests). ➢ Within 60 days of testing soil evaluation forms shall be submitted. Please Do Not Write Below This Line �lJO N.A. Conservation Commission Approval Date: r�� Signature of Conservation Agent. C— 4S'�-o fv"o Date back to Health Department: (stamp in): ` {� o�- b