Loading...
HomeMy WebLinkAboutMiscellaneous - 543 MASSACHUSETTS AVENUE 4/30/2018 543 MASSACHUSETTS AVENUE 210/045.6-00140000.0 l' 4/27/2016 Date:April 26,2016 20088 This is an e-permit.To learn more,scan this barcode or visit northandoverma.viewpointcloud.comfit/recordsl20088 TOWN OF NORTH ANDOVER ' PERMIT FOR WIRING p " "Wd7BY1 kiK This certifies that Matthew T Markham has permission to perform Install solar electric photovoltaic system 18 panels rated at 4.59 kW an STC Grid Tied On roof of existing home. wiring in the buildings of RINGDAHL JR, RICHARD E at 543 MASSACHUSETTS AVENUE, North Andover, Mass. Lic.No. 1136 1/1 _ ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES c w A -".I-AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONIC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT VICINITY MAP INDEX CIRCUIT W WATT - 3R NEMA 3R, RAINTIGHT 1 COVER SHEET JPvPV2 SITE PLAN 3 STRUCTURAL VIEWS • UPLIFT CALCULATIONS LICENCE GENERAL NOTES PV5 THREE LINE DIAGRAM J J Cutsheets Attached 1. ALL WORK TO BE DONE TO THE 8TH EDITION GEN #168572 - ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING ° MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: ZEP SOLAR I AHJ: North Andover i ly r11J I� ' REV BY DATE COMMENTS REV A NAME DATE COMMENTS UTILITY: National Grid USA (Massachusetts Electric) 40 4*0 • JB-0183662 0 0 SSE OWNER: DESCRIPTION: DESIM- CONFIDENTIAL A THE INFORMATION HEREIN JOB NUMBERCliff Williams `\/,`SolarCit CONTAINED SHALL NOT E USED FOR THE WENDY RINGDAHL Wendy Ringdahl RESIDENCE �. " BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNRNG SYSTEM: �.,, r NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 543 MASSACHUSETTS AVE 4.59 KW PV ARRAY - PART TO OTHERS OUTSIDE THE REgPIENTS MODULES: NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH ' 24 St Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (18) TRINA SOLAR # TSM-255PDO5.18 PAGE NAME: SHEET: REV DATE cutin Dive, MA ing 2, SOLARgTY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PV 1 4/12/2016 T.- (650)C630-1028 F:ITY(765-2489)6 wsol-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE380OA—USOOOSNR2 COVER SHEET PITCH: 42 ARRAY PITCH:42 MP1 AZIMUTH: 168 ARRAY AZIMUTH: 168 2 F MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 26 ARRAY PITCH:26 MP2 AZIMUTH: 168 ARRAY AZIMUTH: 168 K. U'cn MATERIAL: Comp Shingle STORY: 2 Stories o CTUFtAL Uxt PITCH: 26 ARRAY PITCH:26 u ST UC � _ No.51933 MP3 AZIMUTH:348 ARRAY AZIMUTH:348 _O0 10 ��1srMATERIAL: Comp Shingle STORY: 2 Stories � �.� SS/pNg4, STAMPED etc SIGNED FOR STRUCTURAL ONLY Digitally' signed by Front Of House Humphrey Kariuki ---- Date: 2016.04.12 LEGEND °_-_' 0 15:21 :48 -04'00' (E) UTILITY METER & WARNING LABEL INVERTER W/ INTEGRATED DC DISCO AC & WARNING LABELS © DC DISCONNECT & WARNING LABELS FAC-1 AC DISCONNECT & WARNING LABELS DC JUNCTION/COMBINER BOX & LABELS Pit 6/1 D DISTRIBUTION PANEL & LABELS 3 � zT�9 Lc LOAD CENTER & WARNING LABELS C B O DEDICATED PV SYSTEM METER Q STANDOFF LOCATIONS ® CONDUIT RUN ON EXTERIOR -- CONDUIT RUN ON INTERIOR GATE/FENCE Q HEAT PRODUCING VENTS ARE RED i. INTERIOR EQUIPMENT IS DASHED L.J SITE PLAN Scale: 1/8" = 1' a O 1' 8' 16' 3 CON — THE INFORMATION HEREIN JOB NUMBER J B-018 3 6 6 2 00 PR�uSE OWNER: DESCRIPTION: DESIGN: CONTTAINEDAINEDAL \\,SHALL NOT BE USED FOR THE WENDY RINGDAHL Wendy Ringdahl RESIDENCE Cliff Williams ' BENEFIT OF ANYONE EXCEPT SOLARCITY INC.. MOUNTING SYSTEM: i..a ,`�OI���I�� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 543 MASSACHUSETTS AVE 4.59 KW PV ARRAY r PART TO OTHERS OUTSIDE THE RECIPIENTS ORGh's:ZATION, EXCEPT IN CONNECTION WITH [MODULES' NORTH ANDOVER, MA 01845 24 St. Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (18) TRINA SOLAR # TSM-255PD05.18 PAGE NAME: SHEET. - �v DAIS Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T. (650)638-1026 F: (650)638-1029 PERMISSION of SOLARCITY INC. SOLAREDGE SE3800A—USOOOSNR2 SITE PLAN 4/12/2016 (BBB)-SCI-CITY(765-2489) www.solarcity.com w �.y S1 K Zi RILIKI v ST UCTURAL NO.51933 4» -0 RFGIST �o 9'—7„ 70, 1'— (E) LBW STAMPED & SIGNET FOR STRUCTURALONLY SIDE VIEW OF MP2 NTS 6 MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 64" 2411 STAGGERED PORTRAIT 32" 15" RAFTER 2x6 @ 16" OC ROOF AZI 168 PITCH 26 STORIES: 2 ARRAY AZI 168 PITCH 26 C.J. 2x6 @16" OC Comp Shingle PV MODULE 5/16" BOLT WITH INSTALLATION ORDER S 1 FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. SEAL PILOT HOLE WITH » ZEP COMP MOUNT C (4) (2) POLYURETHANE SEALANT. 4 9,_6» 70, lam ZEP FLASHING C (3) C3)1 INSERT FLASHING. (E) COMP. SHINGLE 1'— (E) LBW TLOW.EST PLACE MOUNT. (E) ROOF DECKING (5) INSTALL LAG BOLT WITH SIDE VIEW OF MP3 NTS5/16" DIA STAINLESS SEALING WASH R.STEEL LAG BOLT SUBSEQUENT MODULESINSTALL LEVELING FOOT WIWITH SEALING WASHER (6) BOLT & WASHERS. MP3 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES (2-1/2" EMBED, MIN) LANDSCAPE 64 24 STAGGERED „ „(E) RAFTER1 STANDOFF PORTRAIT 32” 15" 1' - ROOF AZI 348 PITCH 26 RAFTER 2X6 @ 16 OC ARRAY AZI 348 PITCH 26 STORIES: 2 C.I. 2x6 @16" OC Comp Shingle PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL A THE INFORMATION HEREIN JOB NUMBER: J B-0183662 00 Cliff Williams SolarCity.CONTAINED SHALL NOT E USED FOR THE WENDY RINGDAHL Wendy Ringdahl RESIDENCE BENEFlT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �,,` NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 543 MASSACHUSETTS AVE 4.59 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: NORTH ANDOVER, MA 01845 24 St. Martin D.,�e,Building 2 Unit 11 THE SALE AND USE OF THE RESPECTIVE (18) TRINA SOLAR # TSM-255PDO5.18 PAGE NAME SHEET: REV. DAIS Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T: (650)638-1028 F: (617 638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE3800A-USOOOSNR2 STRUCTURAL VIEWS PV 3 4/12/2016 (BaB�SOL-CITY(765-2489) www.solarcity.com UPLIFT CALCULATIONS SEE SEPARATE PACKET FOR STRUCTURAL CALCULATIONS. CONFIDENTIAL THE INFORMATION HEREIN JOB NUMBER: JB-0183662 0 0 PREMISE OWNER DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE WENDY RINGDAHL Wendy Ringdahl RESIDENCE Cliff WilliamsBEN NOREFIT OF SHALL ITYONE EXCEPT BE DISCLOSED IN WHOLE ORCITY CINISOLAREDGE MOUNT9IG SMou WI�\SolarCity. Com Mount Type C 543 MASSACHUSETTS AVE 4.59 KW PV ARRAY t PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES- NORTH ANDOVER M A 01845 ORGAN)ZATION, IXCEPT IN CONNECTION WITH 24 St. Martin Drive, Building 2 Unit 11 THE SAL£ AND USE OF THE RESPECTIVE (18) TRINA SOLAR # TSM-255PD05.18 PAGE NAME SHEdT: DATE Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T: (650)638-1028 F: (650)638-1029 PERMISSION OF SOLARCITY INC. # SE380OA—USOOOSNR2 UPLIFT CALCULATIONS PV 4 4/12/2016 (BBB)—SOL—CITY(765-2489) www.8darcity.con e GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (,N) #8 GEC TO TWO (N) GROUND Panel Number:NoMatch Inv 1: DC Ungrounded INV 1 —(1)SOLAREDGE# SE3800A—USOOOSNR2 LABEL: A —(18)TRINA SOLAR TSM-255PDO5.18 GEN #168572 RODS-,AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:13815942 Inverter; 38GOW, 240V, 97.57; w/Unifed Disco and ZB,RGM,AFCI PV Module; 5W, 232.2W PTC, 40MM, Black Frame, MC4, ZEP, 1000V ELEC 1136 MR Underground Service Entrance INV 2 Voc: 38.1 Vpmax: 30.5 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 150A MAIN SERVICE PANEL E 10OA/2P MAIN CIRCUIT BREAKER (E) WIRING Inverter1 CUTLER—HAMMER 10OA/2P Disconnect 2 SOLAREDGE SE380OA—USOOOSNR2 0 (E) LOADS A L1 240V ~ L2 •— N 1 20A/2P ___ GND EGC/ DC+ DC+ ------- A - ------------------------ ------ - GEC ---TN Da Dc- MP2,MP3: 1x18 GNDEGC--------------------------------------- EGC-----------------tJ I I �- N o EGC/GEC_ z � � I I I I I - GEC-r— 1 TO 120/240V SINGLE PHASE I I I I UTILITY SERVICE I I I I I I I I I I I I PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP POI (1)MURRAY#MP2z0 p PV BACKFEED BREAKER A (1)CUTLER—HAMMER #DG221URB /tr PV (18)SOLAREDGE 1�300-2NA4AZS D Breaker, 20A 2P, 2 Spaces Disconnect; 30A, 24OVac, Non—Fusible, NEMA 3R A PowerBox 0 timizer, 300W, H4, DC to DC, ZEP —(2)Gro rid Roo —(1)CU (1)CUTLER—�IAMMER DG03ONB 5r8 x 8, Copper Ground, eutral A; 30A, General Duty(DG) nd (1)AWG#6, Solid Bare Copper —(1)Ground Rod; 5/8 x 8', Copper (N) ARRAY GROUND PER 690.47(D). NOTE: PER EXCEPTION NO. 2, ADDITIONAL ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF (E) ELECTRODE 2O 1 AWG#10, THWN-2, Black (2)AWG#10, PV Wire, 60OV, Black Voc* =500 VDC Isc =15 ADC (1)AWG#10, THWN-2, Red O�(1)AWG#6, Solid Bare Copper EGC Vmp =350 VDC Imp=12.94 ADC (1)AWG X110, THWN-2, White NEUTRAL Vmp =240 VAC Imp=16 AAC (1)Cond4it Kit;.3/4'.EMT .. . . . . . . . . . . . . . . . .. . . .. . . . . . . .. .. . . .. . . .. . . . . . _ .-(1)AWG$8,.THWN72,.Green . . f9PAIEC.7(1)Conduit.Kit;.3/4'.EMT. . . . . , . , . . JB —0183662 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: CONTAINED SHALL NOT BE USED FOR THE WENDY RINGDAHL Wendy Ringdahl RESIDENCE Cliff Williams " BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYMSTEM: W;iSolarCit ® NOR ALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 543 MASSACHUSETTS AVE 4.59 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS Mooul�P NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH �. r 24 St.Martin Drive,Building 2,Unit 11 THE SALE AND USE OF THE RESPECTIVE (18) TRINA SOLAR # TSM-255PDO5.18 PAGE NAME SHEET: REV DAZE Marlborough,MA 01752 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: L (650)638-1028 F. (650)638-1029 PERMISSION of soIARCITY INc. SOLAREDGE SE3800A-US000SNR2 THREE LINE DIAGRAM PV 5 4/12/2016 (886)-SCI-CITY(765-2489) www.solarcityaam A CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 543 Massachusetts Ave AC DISCONNECT r- -------- I L---------- I I I I L----J INVERTER AND UTILITY DC DISCONNECT SERVICE r-------------------- ---- --� l SOLAR PHOTOVOLTAIC ARRAYS) l L--------------------------J ' PHOTOVIOLTAIC BACK-FED gRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V JB-0183662-00 CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-01 83662 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: . CONTAINED SHALL NOT BE USED FOR THE Cliff WIIIIOmS BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: WENDY RINGDAHL Wendy Ringdahl RESIDENCE �`,!�Solt�rCity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 543 MASSACHUSETTS AVE • 4.59 KW PV ARRAY Ilk PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: NORTH ANDOVER MA 01845 ORGANIZATION, EXCEPT IN CONNECTION WITH r 24 St. Martin Drive,Building2,Unit 11 THETtLE AND USE OF THE RESPECTIVE (18) TRINA SOLAR # TSM-255PDO5.18 PAGE NAME: MEET: REV. DATE: Marlborough,MA 0152 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T: (650)638-1028 F: (650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE SE380OA—USOOOSNR2 SITE PLAN PLACARD PV 6 4/12/2016 (88B)-SOL-CITY(765-24889) www.solarcitya«n Label Location: Label Location: Label Location: (C)(CB) f (AC)(POI) ® (DC) (INV) Per Code: - • _• Per Code: _ ® •_• Per Code: NEC 690.31.G.3 •• • o NEC 690.17.E • ° • o_ �• NEC 690.35(F) Label Location: • '• - • • • • TO BE USED WHEN (DC) (INV) , •'o o s o `• • • • • • INVERTER IS Per Code: ' UNGROUNDED NEC 690.14.C.2 Label Location: Label Location: - • • • -• • (POI) (DC) (INV) - o • ® Per Code: • _ Per Code: .-® .° o • NEC 690.17.4; NEC 690.54 -O NEC 690.53 • �II Label Location: •- • ® (DC) (INV) Per Code: .® o ° • .• ° ® NEC 690.5(C) •` `• • • Label Location: • • •- (POI) on Per Code:NEC 690.64.B.4 Label Location: r (DC) (CB) Per Code: Label Location: •® ® ® NEC 690.17(4) (D) (POI) • =• • Per Code: ®-• '-® ® . NEC 690.64.B.4 • o0 Label Location: (POI) Per Code: ysy° Label Location: ° ® ° NEC 690.64.B.7 ® (AC) (POI) •• • - • • (AC):AC Disconnect ® Per Code: °! - (C): Conduit NEC 690.14.C.2 (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit iu pi � I„ij Label Location: (INV): Inverter With Integrated DC Disconnect (AC) (POI) (LC): Load Center °- Per Code: (M): Utility Meter °. • NEC 690.54 (POI): Point of Interconnection CONFIDENTIAL— THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR >M j 3055 Clearview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED ��• San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, Label Set �•�.�` T:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION WI1H THE SALE AND USE OF THE RESPECTIVE I1�S�Dh1"CI (888}SOL-CIfYp65-2489)wwwsolarcty.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. o 1�1 " SolarCity ®pSolar Next-Level PV Mounting Technology i',SOlarCity ®pSolar Next-Level PV Mounting Technology Zep System Components for composition shingle roofs r i s roof } Leveling Foot Intertoek c�"°„edze� t'�s`�°� +`r' Part No.850-1172 Levclkv Foot , ETL listed to UL 467 Z¢D CompatEtle irlt Modulo _�.,,n:,_�.—�•. - �x a4L _ e .. hoot Attachment Array sWrl 4= - Comp Mount Part No.850-1382 Listed to UL 2582 Mounting Block Listed to UL 2703 ~� of Description , PV mounting solution for composition shingle roofs ` FA a Works with all Zep Compatible Modules REIM] aMPPI Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" Interlock Ground Zep V2 DC Wire Clip UL LISTED Specifications Pad No.850-1388 Part No.850-1511 Part No.850-1448 Listed to UL 2703 Listed to UL 467 and UL 2703 Listed to UL 1565 • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards kv= • Zep System grounding products are UL listed to UL 2703 and UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72"and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Array Skirt,Grip, End Caps Part Nos.850-0113,850-1421, 850-1460,850-1467 zepsolar.com zepsolar.com Listed to UL 1565 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation.shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM Document#800-1890-001 Rev A Date last exported: November 13,2015 2:23 PM c� p soar=20 solar+ o SolarEdge Power Optimizer Module Add-On for North America P300 / P350 / P400 SolarEdge Power Optimizer _ Module Add-On For North America P3D0 Pisa Paoo (fpr 60-cell PV (for 72-cell PV (for 9PV modules) modules) modduulele s) P300 / P350 / P400 ® INPUT _ Rated Input DC Power') 300 350 400 ....... .. W .. ............. Absolute Maximum Input Voltage(voc at lowest temperature), 4860 80 Vdc E MPPT Operating Range848 860 8 80 Vdc - - ® Maximum Short Circuit Current(Isc) 10 Mi ... ........_.. ....... ..... .... .............. 8 . A�d c .. - . . . MaxmumDCInputCurentAdc .. . . .. 12.5 ....... aximum Efficiency 9. 9.5. .. ... % ........ 98Weighted Efficiency .. `+ Overvoltage Category II V. r -r -_ r 'I OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) ' R — — — — Maxium tput Current mOu35 Adc r Maximum Output Voltage 60 Vdc - OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE ... .� -"", _ ._.,_ ..._ ' EMC FCC Part15 Class B IEC61000 6 2 IEC61000 6 3 k .; ... .. .... ..... ..... ... .... ... ... .. .... ..... .... $: ! t Safety I IEC62109-1(class II safety),UL1741 . n . ... ..... ... .. ..... ....-... .. .......... RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions x L x H) 141 x212x40.S/5.S5x834xl.59 mm/in ,a. r .... ..... ... .......... .... .... ...._. .................... Weight(including cables) 950/2.1 ,. Input Connector MC4/Amphenol/Tyco .... ... ....... ...... .. ..... .. ...... ................. ......... F` Output Wire Type/C nnector Double Insulated,Amphenol - - Output Wire length �. 0.95/30 1.2/3.9 m/ft .. ......... .... .... ..� .... .. .. .. . . ..... ... Operating Temperature Range 40-+85/-40-+185 'C/" ......... .. .. ......._.. ........ _..... ..-................ .._..-..................... ......._... $ Protection RatingIP65 NEMA4 - '- Relative Humidity 0-100 I % ..... ................ .. .... . ..... ............ Rand sre eowc,ef dm d. __....._... .... ............... „ - .......,-._ ...._........... ......._ ......... -. .. A, PV SYSTEM DESIGN USING A SOLAREDGE SINGLE PHASE THREE PHASE THREE PHASE INVERTER 208V 480V ,PV power optirraiZatiorl-at the hTpClG1E+.„l ..�(E!I ” "K 41 Minimum String Length(Power Optimizers) 8 10 18 UA to 25%more energy Maximum Stnng Length(Power Opti .............. . 25, ..... ,.. .25 .,50„ �-a _ - '- _ Maximum Power per String 5250 6000 12750 W SuperwreNlcl@ncy(99.5%) ( ..................... ..... ...... ..... ..... Mitigates all types of module mismatch losses,from manufacturing tolerance to artial shading Parallel Strings of Different Lengths or Onentations yes YP g ,z ?., g. ., ...... .. .. .ren.......... ..t .. ... .... .. _ x e Fle>29blesystemdesign for maximum spaCeutilization Fast installation,-with asingle..bolt . - - - ..... , - ,�_._... _ _. —. .........._.. - Next generation maintenance with module-level monitoringx — Module-level voltage shutdown for installer and firefighter safety s i USA - GERMANY - ITALY - PRANCE. - JAPAN CHINA - ISRAEL - AUSTRALIA WWW.SOlared.-e.US THE Trinximount MODULE TSM-PD05.18 Mono Multi Solutions DIMENSIONS OF PV MODULE ELECTRICAL DATA 0 STC unli:mm Peak Power Watts-Pmnx(Wp) 245 250 255 260 --- - Power Output Tolerance-P-x(%) - - _ 0- 3 E VUTHE /+� 941 f \ MaximumPower Curree-I (V) 29.9 30.3 30,5 30.6 THE `�// macTioN nt 'j maximum Power CurrentamrE(A) 8.20 8.27 8.37 8,50 ;T N_lp EE - c Open Circuit Voltage-Voc(V) 37.8 38.0 38.1. 38.2 Short Circuit Current-.lsc(A) 8.75 8,79 8.88 9Q0 i . grr..•. wsuuwc NorE � ( - E 3 MODULE Module Efficiency qm(%) 15.0 I Icor 0 05.6 15.9 STC:Irradiance 1000 W/m',Cell Temperature 250C.Air Mass AM1.5 according to EN 60904-3. Typical efficiency reduction of 4.5%at 200 W/m2 according to EN 60904-1. 0 0 1 ELECTRICAL DATA CN NOCT - ■ Maximum Power-P-(W p) _ 182 186 190 : 193 a L i :Maximum Power Voltage-Vax(V} 27.6 28.0 28.1 28.3 3 MULTICRY.STAI.LINE MODULE e-m..scaouNDING-E Maximum Power Current-IMPP(A) 6.59 6.65 6.74 6.84 WITH TRINAMOUNT FRAME 11' a-0xaNNorE g A Open Circuit Voltage(VJ-Voc IV) 35.1 35.2 , 35.3 35.4 -- - __ _ ` Short Circuit Current(A)-Isc(A) 7.07 7.10 7.17 7.27 if NOCT:Irradiance at 800 W/m',Ambient Temperature 20°C.Wind Speed I m/s. PD05.18 � 812 iso �f , Back View POKER OUTPUT RANGE 1 MECHANICAL DATA Solor cells Multicrystalline 156 x 156 mm(6 inches) s d ' Fast and simple to Cell orientation cells(6 x 10 instal[through drop in mounting solution ) tE � tl � - t Module dimensions 1650 x 992 x 40 mm(64.95 x 39.05 x 1.57 inches) Weight 21.3 kg(47.0 lbs) - MAXIMUM EFFICIENCY I Glass 3.2 mm(0.13 inches).High Transmission,AR Coated Tempered Glass A-A Backsheet.. White Good aesthetics for residential applications Frame Black Anodized Aluminium Alloy with Trinamount Groove J-Box IP 65 or IP 67 rated 0--+317o ; FV CURVES OF PV MODULE(245W) Photovoltaic Technology cable 4.0 mm2(0.006 inches2), 0 I - Cables ._.... ....___. .__.--- -..__.... ......... ......_..- ......... 180 1200 mm(47.2 inches) POWER OUTPUT GUARANTEE Fire Rating Type 2 -- -- - 7m 800W/m2 _ Highly reliable due to stringent quality control _ W I`6DOWlin- • Over 30 ir,-hcas<:tests(JV,Tom,Hl=,arid many more) _-- .s a lecid:ng global manufacturer i-1-house testing goes`%Jell bcycnd ce tificaiion recuirennei is U a.� 00Wlm2 TEMPERATURE RATINGS MAXIMUM RATINGS of next generation photoelta"te �.__._ am pr 2°p 20oW/m2 Nominal Operating Cell 44°C +2° Operational Temperature -40-+85°C Oaxt g ne L`ellnVe CI056 -, (- C) COaperatia:✓•rtfh Oi!r oa"'rets '"-.\ Temperature(NOCT) Maximum System 1000V DC(IEC) is Critical to Success. `:'+`ith local0fO !Temperature Coefficient of P- -0'.41%/°C Voltage 1000V DCIUL) o.m to.- 20F° 30m 40.. presence CrOUnd the globes Trina is Temperature Coefficient of Voc -0.32%/°C Max Series Fuse Rating 15A Voltagev) _ able to provide eyce r;nal service Temperature Coefficient of Isc 0.05%/°C tz.each mel m each Irlarkct r Certified to withstand challenging environmental and ole nt our In: oval ve, conditions el abic products r ith the backing 2.00 Pa Wind load or Mina JS a Orong,bankable �^^'� WARRANTY I partner. We are committed 54G0 Pa snow lord � 10 year Product Workmanship Warranty to building strategic,mutually beneficial collaboration with 25 year Linear Power Warranty installers,developers,distributors (Please refer to product warranty for details) a and other partners as the II backbone of our Shared Success in - - CERTIFICATION - drivingsmartEnergyTagether. LINEAR PERFORMANCE WARRANTYPACKAGING CONFIGURATION T (S I) 10 Year Product Warranty•25 Year Linear Power Warranty � `, ��� Modules per box:26 pieces �z Trina Solar Limited Modules per 40 container:728 pieces W Y/W.t'ir:CSOICCCCr':"i m100% � 1 m ..____....__Aatlitia __.....f.ro....nopolsluve r.. .. w Ecov8.EuEnENEr 9o% o rin4SOlor SWarrant CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. Na ptkPA r,0 0 02014 Trino Solar Limited.All rights reserved.Specifications included in this datasheet are subject to 2 80% ichangewithout notice.�ryrwgJ( a^ Tynn-ascil ^ / v Smart Energy Together rears s to is 20 25 Smart Energy Together A°aerrnca ' Tri€'iastandard Ind_s¢f't-d"re ey fi so o single Phase Inverters for North America solar ® m © ® SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ _ SE7600A-US/SE10000A-US/SE11400A-US _ SE3000A-US 800A-USS SE5000A-US LSE6000A-USI SE7600A-USI SE10000A-US SE1140OA-US OUTPUT _ __-._.... .... .- Nomin 9980 @ VA SolarEdge Single Phase Inverters 208Val AC Power Output 3000 3800 5000 6000 7600 11400 - .., - ......... i � 10000 240V . 5400 @ 208V 10800 @ 208V • - " Max.AC Power Output 3300 4150 5450"�240V 6000 8350 10950�240V 12000 VA For North America . ... ." . .. .. AC Output Voltage Min.-Nom.-Max.(') i 183-208-229 Vac - . . . ......... ...... .. �.... ...... - ✓ - SE3000A-US/SE380OA-US/SE500OA-US/SE600OA-US/ Min.-Nom.-Max.(')- <r , r. . AC Output Voltage ✓ ✓ ✓ ✓ ✓ ✓ ✓ SE760OA-US/SE10000A-US/SE1140OA-US 211 240-264 Vac ..... ...... ...... . ( ... ... ... . .... AC Frequency Min:Nom.Max.i') 59.3-60 60.5(with HI country setting 57-60-60.5) Hz ......... ....... ... .... ... ......... .... .. ... .. .. ......, .......�- 48 @ 208V Max.Continuous Output Current 12.5 ( 16 25 32 47.5 A .,........21,e7a,240V.......... .. ..!. .. ........ .4�.@.240V... . ^t e• ��.,,:; -_^. .; _ GFDI Threshold. ...... .......... ..... ...... ..... .............. .. .1..... . . ... ... ......................... ....._...... .A..... Utility Monitoring,Islanding Protection,Country Configurable Thresholds Yes Yes a s, INPUT Maximum DC Power(STC) 4050 5100 —, 6750 8100 1025013500 15350 W Transformer-less,Ungrounded Yes i412. c . ... ..... .... ......... .. . ... . ... .... ...... . .... .. m - M ... . . . . . ... . ........ .. .... .. . . ..... ..... ... .... . . ... . ... .. Wa¢a Nom. InputtVoltage 325 @ 208V/350 @ 240V Vdc" �Yf ..... .. ... .. ..... .i ... ... ... ......... 16.. .SV ..... . .... .. x +a.12aN�� ' - Max.Input Currents') 9.S 13 .5 20 18 23 33 @208V � 34.5- Adc -. .` ..... ..... ........... .. . . , . . -........ .. .. ..15;5. 240V. .. . ........�. . . .; .305, ,240V .. . . . . . . . . .. ...... itCurrent. ... . .. ... .. .. .................... .. .. 45.... ..... ... .... . .. . . . . . . . i...Adc.... . I ` Reverse Polarity Protection. . ... .. ..... .. .. .......... ....... . . eS ... .., . . . .. ... ......... f Ground Fault Isolation Detection 600kn Sensitivity Maximum Inverter Efficiency." . ..- ..97.7- .98.2. - 98.3. - 98.3. t ..... ... .ri. e ... ,". .. . . . I 1 97.5 @ 208V I 97 @ 208V " CEC weighted Efficiency 97.5 98 1 97.5 97.597.5 F - ..... ..., .,• Nighttime Power Consumption <2.5 <4 W ADDITIONAL FEATURES _. _a_. J Supported Communication Interface RS485,RS.... Ethernet,2igBee(optional) UIUi', . . . . .... . ... . ... . .. Revenue Grade Data ANSI C12.1 Optionalia) ..... . . . .. . ... .. .. . .. ... .. . .. .. . . .. " Rapid Shutdown-NEC 2014 690 12 Functionality enabled when SolarEdge rapid shutdown kit is installed(4) STANDARD COMPLIANCE _ Safety UL1741,UL1 i? y CSA 22.2 Gnd Connection Standards.... ..... ....... ..... ....... .. ....... ...............IEEE1547 ..... ............... . . ........... . ...... .. . ..,.. ... ,.. d. ......t ... ... .. .. ....... . .. .... ... .... .. .. .... . . ..... ......... Emissions FCC partly class B INSTALLATION SPECIFICATIONS i ...._... _ AC output conduit size./AWG range 3/4"minimum/16-6 AWG 3/4"minimum/8-3 AWG DC input conduit size/#of strings/ 3/4"minimum/1-2 strings 3/4"minimum/1-2 strings/16-6 AWG - m "AWG range. . . . . < ... ... 14-6 AWG Dimensions with Safety Switch 30.5 x 12.5 x 10.5/ in/ - """ 305 x 12.5 x 7.2/775 x 315 x 184 ----, - „- „ " 775x315x260 Weight with Safety Switch ..... .. 51.2/232 .�. ... ...... ... 54,7/24.7. I ....._...-88..4./40.1. .... _...,...,...........-Ib/k .. Natural convection Cooling g N u I Convection and sfan(user Fan ( replaceable) in at ra suser re laceable The best choice for SolarEdge enabled systems ) - Noise. ... . .. . .,. ..... ... . ........ <25 ..<50.... ...... .. dBA -" Integrated arc fault protection(-type 1)for NEC 2011 690.11 Compliance" Min:Max.Operating Temperature 13 to+140/ 25 to+60(40 to+60 version availableis)) -F r. .: .;; "Rang?...... ..... ... ....... . ......... . ... 3 -":SDperiorQfficiency198%), t «. � r. � ........ ...... .... Protection Rating I NEMA 3R ..... ... ... . ........... .... . . ...... .. ... ............ ..... .. .. .. ... ... ... ..... .. .. .. ... .......... Small,lightweight and easy,to Install on provided bracket For other regional settings please contact SolarEdge support. A higher current source may be used;the inverter will limit its input current to the values stated. Built-In module-level monitoring is)Revenue grade Inverter P/N:SExxxxAUS000NNR2(for 760OW'nvert—SE7600A-US002NNU). Rapid shutdown kit P/N SE1000-RSD-Sl. Internet connection through Ethernet Or Wireless 14 AO version P/N SExxxrA-USOOONNU4(for 760OW mverter:5E7600A-US002NNU4). Outdoor and indoor installation 4 Fixed voltage inverter,DC/AC conversion only Pre-assembled Safety Switch for faster installation Optional—revenue grade data,ANSI C12.1 USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-1HE NETHERLANDS-ISRAEL www.solaredge.us Date... . .� O. 3.... pORTM °�<"`°;•�"� TOWN OF NORTH ANDOVER p PERMIT FOR WIRING SSACHU 4 C rThsrtifes that .. ............................ . 4 ......1.............................. has permission to perform C. Gom O up A W� .. !uh °r� aQ ..... ......... wiring in the building of......... .....W`.. .................................................... 5 `x.3 W1ASS Au at................ .......................................................,N Andover,Mass. Fee..................... Lic.No. a.l.q.aI ...... - ... .. ELECTRICAL INSPECTOR Check # 4436 � THEC0jW0NWE4LTH0FM4YS4CffUSE77N Office Use only DEPARTMFVTOMBLICS4MY Permit No. BOARD OFFIREPREVENI70NREGUL4H0 N527CMR 12.00 WAPPERMITCATIONFOR Occupancy&Fees CheckedPLITO PERFORMELECTRICAL WORK ALL WORK TO BE PERFORMED IN ACCORDANCE WITH THE MASSACHUSSTS ELECTRICAL CODE,527 CMR 12:00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date 4-i r03 Town of North Andover To the Inspector of Wires: The undersigned applies for a permit to perform the electrical work described below. Location(Street&Number) 541 M ctss Ave Owner or Tenant 1-RIr.hnrd. E wQdah 3"K Owner's Address /'14S,SVF— No. Ar000I/e2_ t , ..,.�� Is this permit in conjunction with a building permit: Yes M No (Check Appropriate Box) Purpose of Building 61AIC-LF hAtolid llYyM Utility Authorization.No. Existing Service )UO Amps Za /Z4D Volts Overhead E] Underground Q No,of Meters New Service IDO Amps)20/240 Volts Overhead r--J Underground No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work (J'd%e oar-Sloe OVeewmp 7a uAEC-z around No.of Lighting Outlets No.of Hot Tubs No.of Transformers Total KVA No.of Lighting Fixtures Swimming Pool Above Below eneratots KVA eround ground No.of Receptacle Outlets No.of Oil Burners No.of Emergency Lighting Battery Units No.of Switch Outlets No.of Gas Burners No.of Ranges No.of Air Cond. Total FIRE ALARMS No.of Zones Tons No.of Disposals No.of Heat Total Total No.of Detection and Pumps Tons KW Initiating Devices No.of Dishwashers Space Area Heating KW No.of Sounding Devices No.of Self Contained . Detection/Sounding Devices No.of Dryers Heating Devices KW Local Municipal Other Connections �. No.of Water Heaters KW No.of No.of Signs Bailasis No.Hydro Massage Tubs No.of Motors Total HP OTHE • r IrtstrartoeC.aa�e Putsuat�tbthetegt>Qerr>Ier��GaxialLxw+s (j�� Iha%eaa�nettIiatnldyTimratoePbbtyerh>cfmgCa a m Cosubstat#ialegtdvalatt YES M NO 2 IhMe%bniaedNaWpta(afsame1othe0ffioe.YES NO Ifjcuhmdw*c dYES,PImetdic*thetypeofwma@ebydwckwgthe NaROCE ca BOND o 0`11.IER o_. W11,L CAS Rtan*dVakrdMeeliifalWcak.$. . WadcbSta;t / hWaidmDtdeRa4)esed Rough Fs>al �®® Si&W Ulkr7FC%MtiM*ajtey. FIRM NAME liarseNa t1ie�14r� �In�ja�t�l� Uig Signatiae .21427 E Bt t srrlessTeLNa GQ+°j3-2'13 2x905,13 x90 Arklrr c j 13 A cfw; Ave /V0, Aln"'ve't- Ak.Tel.Na �� -rte, -.q0 f g OWNER'SI1VS<JRANCEWAIVER;Iamawat dAtheLi=wdmndtheuntran ahemgp ssksbnialepwAutasm medbyNtsmdxsettsCamidLa aod�mysigtr�taemilaspamitappliratiattwait�sthis tetluaertag. (Please check one) Owner Agent Telephone No. /*LRJ- '018 PERMIT FEE$ The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations :. Ff Boston, Mass. 02111 �o�M s�.y Workers'Compensation Insurance Affl-davit Name Please Print yy , Name ��rr�uc� E ►ty c � ' c�rL, Location: 5,43 /1 A� City h o, Aly oyE 2 Phone # I am a homeowner performing all work myself. I am a sole proprietor and have no one working in any capacity I am an employer providing workers'compensation for my employees wiorking on this job. Company name: Address cihc. Phone#. Insurance.Co. Policv# Company name: , Address City: Phone* Insurance Co. Policy#' Failure to secure coverage as required.under Section 25A or MGL 152 can lead to the imposition cf criminal penalties or,a file up to$1,500.t>D m and/or one years'imprisonents weiLas_civil4wnaliminlhelarm-dA DPlr1t_'ORK_o�R zodafm-_dA$1110_Ma�al► mp- understand that a copy of this statement may be forwarded to the Office of Investigations of the DIA for coverage verification. I do hereby certify under Me pains and penalties of perjury that the information provided above is true and correct. Signature Print name / a r d 1!v Ct h JR Official use only do not write in this area to be completed by city or town official' City or Town p Building Dept []Check if immediate response is required ❑ • Lkensigg;Board\ E! Selechmn's Office Contact person: Pune#: Health Department Other