Loading...
HomeMy WebLinkAboutMiscellaneous - 54A Woodcrest Drive I� +54A WOODCREST DRIVE i r40RTM °tq4° 3� BOARD OF HEALTH YA # 120 MAIN STREET TEL. 682-6483 7 ADAA TiD rTP"'�y 9isgCHUS�t NORTH ANDOVER, MASS. 0184 hh� Ext. 32 or 52 \v 8:00 P.M. TOM NEVE - 54A WOODCREST DRIVE - VARIANCE - 310 CMR 1503 (7) • Mr. Tom Neve, Engineer, and owner Robert Webster were present. Mr. Neve designed a septic system for Mr. Webster and is coming before the Board for a variance to Title V, allowing the use of a concrete barrier to cure the slope breakout re uirements. Mr. Neve stated that he received Mr. Rosati 's comments and he revised the plans to try and comply and tried to find the best solution. On a motion by Mr. Osgood, seconded by Dr. MacMillan, the Board voted unanimously to grant the variance with provisional approval with Mr. Rosati. Mr. Neve also stated that this system was designed on 150 gallons per bedroom per day. Mr. Neve wants the Boards a the size of the system based on 150 gallons approval to keep enlarge it accordinggallons to 165 g Per bedroom and not , he recently revised regulations Mr. Neve would bedroomper according ctodask foranofficial waiver to respect to that. Mr. Rosati asked Mr. Neve how much bigger does he think the system has to be? Mr. Neve stated it will probably take another 10 gallons. Mr. Rosati asked if there was any reason why this can not be done. Mr. Neve stated "No", there is never a reason why we can't put in a system bigger than we have. Dr. MacMillan asked Mr. Rosati if he thinks the Board is setting a precedence if the Board allows the waiver. Mr. Rosati responded affirmatively. Mr. Neve stated that it is a fairness question and this is all he is asking for. Mr. Osgood stated that he does not have a gallons vs. 165 gallons but he would have a problem problems giving blanket approval for everything because he does not know what the other issues are. Mr. Rosati stated there are other issues. For instance, the reserve areas are not separated by four feet, it is back to where 11 the wall was this is why Mr. Rosati suggested that the wall be placed further away from the system. i On a motion by Mr. Osgood, seconded by Dr. MacMillan, the Board voted unanimously to waive the new local regulation of 165 gallon per bedroom per day and to allow the system to be designed for 150 gallon per bedroom per day according to the old local regulations and further move all other differences between the new and old local regulations be worked out between Mr. Rosati and Mr. Neve. If they are unable to work them out, Mr. Neve will be requested to come before the Board.