HomeMy WebLinkAboutMiscellaneous - 59 ROCKY BROOK ROAD 4/30/2018 (5) Commonwealth of Massachusetts
Title 5 Official Inspection Form
a Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
wM 59 Rocky Brook Road
Property Address
Russell Norris
Owner Owner's Name
information is
required for North Andover MA 01845 11/16/2009
every page. Citylrown State Zip Code Date of Inspection
B. Certification (cont.)
2. System will fail unless the Board of Health (and Public Water Supplier, if any)
determines that the system is functioning in a manner that protects the public health,
safety and environment:
❑ The system has a septic tank and soil absorption system (SAS) and the SAS is within
100 feet of a surface water supply or tributary to a surface water supply.
❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water
supply.
❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water
supply well.
❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or
more from a private water supply well**.
Method used to determine distance:
**This system passes if the well water analysis, performed at a DEP certified laboratory, for coliform
bacteria indicates absent.and the presence of ammonia nitrogen and nitrate nitrogen is equal to or
less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis must be
attached to this form.
3. Other:
i
D) System Failure Criteria Applicable to AII'Systems:
You must indicate"Yes"or"No"to each of the following for all inspections:
Yes No
❑ ® Backup of sewage into facility or system component due to overloaded or
clogged SAS or cesspool
❑ ® Discharge or ponding of effluent to the surface of the ground or surface waters
due to an overloaded or clogged SAS or cesspool
❑ ® Static liquid level in the distribution box above outlet invert due to an overloaded
or clogged SAS or cesspool
❑ ® Liquid depth in cesspool is less than 6" below invert or available volume is less
than 1/2 day flow
l5ins•09/08 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 4 of 17