HomeMy WebLinkAboutMiscellaneous - 59 ROCKY BROOK ROAD 4/30/2018 (25) 0 Page 5 of-11 OFFICIAL INSPECTION FORM -NOT FOR VOLUNTARY ASSESSMENTS SUBSURFACE SEWAGE DISPOSAL SYSTEM INSPECTION FORM PART B CHECKLIST Property Address: 59 Rocky Brook Road- - North Andover_ Owner:_Powell_ Date of Inspection:_9/27/2003_ Check if the following have been done.You must indicate"yes"or"no"as to each of the following: Yes No Yes_ _ Pumping information was provided by the owner,occupant, or Board of Health No Were any of the system components pumped out in the previous two weeks? Yes_ _ Has the system received normal flows in the previous two week period? _No_ Have large volumes of water been introduced to the system recently or as part of this inspection? Yes _ Were as built plans of the system obtained and examined?(If they were not available note as N/A) Yes_ _ Was the facility or dwelling inspected for signs of sewage back up? _Yes_ _ Was the site inspected for signs of break out? _Yes _ Were all system components,excluding the SAS,located on site? _Yes_ _ Were the septic tank manholes uncovered, opened,and the interior of the tank inspected for the condition of the'baffles or tees,material of construction,dimensions,depth of liquid,depth of sludge and depth of scum? _Yes_ _ Was the facility owner(and occupants if different from owner)provided with information on the proper maintenance of subsurface sewage disposal systems? The size and location of the Soil Absorption System(SAS)on the site has been determined based on: Yes no Yes— _ Existing information. _No_ Determined in the field(if any of the failure criteria related to Part C is at issue approximation of distance is unacceptable)[3 10 CMR 15.302(3)(b)] I i