Loading...
HomeMy WebLinkAboutMiscellaneous - 65 BOSTON STREET 4/30/2018 (2) 65 BOSTON STREET / 210/107.6-0057-0000.0 I I i I Date... TOWN OF NORTH ANDOVER PERMIT FOR WIRING �Ss�CHUSf This certifies that ..................... ..................... has permission to perform ...... wiring in the building of...................... . � ....................................... at. zra.;'r.....5;. .... ........ ... ,North Andover,Mass. Fee..-R. " ' .No.-3W211............. 4LECTRICAL IiNSPEcrOR Check # 10436 Commonwealth of Massachusetts Official Use Only Department of Fire Services Permit No. t�9 3 Occupancy and Fee Checked BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] leave blank APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code( C) 527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: #/j 1 19 City or Town of: NOR'T'H ANDOVER To the Inspec or of Wires: By this application the undersigned gives no ice of his o her intention to perform the electrical work described below. Location(Street&Number) O5 Owner or Tenant "At ,� Telephone No. Owner's Address Is this permit in conjunction with a buil ing permit? Yes ❑ No (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead ❑ Undgrd ❑ No.of Meters New Service Amps / Volts Overhead ❑ Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work lit( I u 70 DAWe q1 X/& Completion of the ollowing table may be waived by the Inspector o Wires. No.of Recessed Luminaires No.of Ceil:Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA Above In- No.—Of Emergency Lighting No.of Luminaires Swimming Pool rnd. ❑ rnd. El Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Total No.of Alerting Devices Tons No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: Detection/Alerting Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other Connection No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No. of Water KW No.of No.of Data Wiring: r Heaters Signs Ballasts No.of Devices or Equivalent iio.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring: No.of Devices or E uivalent OTHER: Attach additional detail if desired, or as required by the Inspector of Wires. Estimated Value of Electrical Work: `�- (When required by municipal policy.) Work to Start: -' Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in fo ce,and has exhibited proof of same to the perm' iss mg o]f e. CHECK ONE: INSURANCE [ BOND ❑ OTHER ❑ (Specify:) / I certify,under the paid d penaltd XT4-171( f pe jury,tha5ghe ration on this application is true and complete. FIRM NAME: <1 I/10A CIO 4w LIC.NO.: Licensee: `j kJ �Cl 4 Signature LIC.NO.: (If applicable, enter,exe7t"i h�jlicen�,e number line. u � 4g Bus.Tel.No.: Address: �a- �1 tC/( *- 0tAlt.Tel.No.: *Per M.G.L c. 147,s. 57-61, security work re fres Department o Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑ owner's Owner/Agent Signature Telephone No. PERMIT FEE: $ - ,17 —7 Date......1.2 --�* ........................... 4oRTpf , '.. 1. TOWN OF NORTH ANDOVER PERMIT FOR WIRING This certifies that ....... ......'s..C-.. has permission to perform ...........I ........... wiring in the building of............... ......................................... at................ North Andover,Mass. Fee... Lic.No..I.Irl�................... ]KEMICAL INSPECTOR Check # OV 7207 r T Commonwealth of Massachusetts official Use Only Permit No. ?7-e Department of Fire .services Occupancy and Fee Checked _ BOARD OF FIRE PREVENTION REGULATIONS [Rev-9/05] leave blank APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CtMR 12.00 (PLEASE PRINTW INK OR TYPE'ALL INFORMATI019 Date: � City or Town of: Ne 2 i lf- Axj�,->o vel To the Inspector of Wires. By this application the undersigned gives notice of his orher intention to perform the electrical work described below. Location(Street&Number) s 5 OS-7-d7) -SL-7, Owner or Tenant P14/L S-�4,e_c_•S Telephone No. g 7 e--�,000_1f51o/ Owner's Address Is this permit in conjunction with a building permit? Yes ❑ No (Check Appropriate Boz) Purpose of Building Utility Authorization No. Existing Service Amns / _Volts Overhead ❑ U.ndgrd ❑ No. of.Meters _ New Service Amps / Volts Overhead ❑ Undgrd ❑ No.of Meters Number of Feeders and Ampacity 71 Location and Nature of Proposed Electrical Work: O S--.tt e_-F i dr, 2 r^ =N Completion o the followingtable may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of CeilSusp.(Paddle)Fans o.of Total : t1 Transformers KVA t No.of Luminaire Outlets No.of Hot Tubs Generators KVA Above In- o.o mergency Lighting No.of Luminaires Swimming Pool' rnd. � rnd. � Batte Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners o.o Detection and Initiating Devices Tot No.of Ranges No.of Air Cond. Tons No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons o.o elf- ontatned P Totals: - Detection/AlertinDevices ' mal No.of Dishwashers Space/Area Heating KW Connectioft El Other Heating Appliancesuri S No.of Dryers y evices or Equivalent o.of Water. inx, No.o o.of Data Wiring: Heaters Signs Baliasts I No.of Devices or r uivalent No.Hydromassage Bathtubs No.of Motors Total HP el No of Deviceio r Wiring: No.of Devices or Equivalent _ OTHER: i Q 7- e9 D Ga 7/ Attach additional detail if desired,or as required by the Inspector of Wires. ma t` Estited Value of Electrical Work 1 (45-. (When required by municipal policy.) Work to Start: Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office: CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:) I certify, under the pains and penalties ofperjury,that the information on this application is true and complete. _ FIRM NAIVE: ADT Security Services,Inc. LIC.NO.:�5 .:�3 Licensee. TAY/02_Tk— _ SignaturLIC.NO.:_LCw (Ifapplicable,enter "exempt"in the license number line) Bus. fel.No.-(� 0:; TN-15 R0 Address: Alt.Tel.No.:-1- 3 S��/56tid *Security Svstem Contractor License required for this work; if applicable, enter the license nu-tuber here:ss C,6 jOL OWNER'i INSURANCE WAIVER: I am aware that the Licensee does no:have the liability insurance coverage normally required by law. By my signavare below,I hereby waive this requirement. I am the(check one) ❑ owner ❑ owner's agent Owner/AgentPF p, ,,llz're'.E; Q Signature Telephone No. &ommww� Department of Public Safety t One Ashburton Place, Rm 1301 Boston, Ma 02108-1618 License: SEC SYS CERT. CLEARANCE Birthdate: 12/23/1974 Number: SS CC 002577 Expires: 12/23/2007 Restricted To: 00 WILLIAM M TAYLOR JR 18 CUNTON DR HOLLIS, NH 03049 Tr.no: 67.0 Keep top for receipt and change of address notification. DPS-CA1 a 50M-05108-PC8490 f ✓!e TDommovuueczll�i a�✓f�laaaacleuvell` DEPARTMENT OF PUBLIC SAFETY License: SEC SYS CERT.CLEARANCE Number: SS CC 002577 Birthdate:,12/23/1974 Expires: 12/23/2007 Tr.no: 67.0 - Commonwealth of Massachusetts Restricted: 00 Division of Registration_ WILLIAM M TAYLOR.JR'= _ Board of Electrical Exaafin €M— 18 C_NTON DR HOLLIS, NH 03049 DIG SAFE CALL CENTER: (888)344-7233 T Y91 :_ Commissioner WILLIAMlV11 j 27 STONC_H ;4 APT 6 ! - LONDONDERF� X33218290 Systems Technicrart= 10099-D 07/31/200 7 \�'—' 003217 t License No. Expiration Date. Serial No, is i< r _ ti NORTH O?p1`,..0 ,s1ti0� TOWN OF N RTH AtbOVER • - PERMIT FOR G S INSTALLATION • �a O� SACeHUSEtS This certifies that . . !!l . fl. . . . . . . . 'll:V !!'a• • • •� � has permission for gas installation . . .F �f!a . . . �-�. . . . . . . . . . in the buildings of . . . . . l . !. . . . . . . . . . . . . . . . . at .Pr C . . . ./,,err ���,�. . . .< :1� . . . . . ., North/Andover Mass. :X Fee b! ..�� Lic. No..!3f.0 k), . i'-��� Al-. /�-:�-:. . . . . . . GAS INSPECTOR Check# 6.1 03 MASSACHUSETTS UNIFORM APPUCATON FORPERIVIlTTO DO GAS FITTING (Type or print) Date 02"7 NORTH ANDOVER, MASSACHUSETTS Building Locations S� �� �"°"" Sc� Permit# Amount$ ,..,,, / Owner's Name �� ��'�W C New'C� Renovation 0 Replacement Plans Submitted D v, U a vi o z z Z x I T a x v, [� w p o p Z N w x �- y a a > e C7 F Z F z [�" C7 p > Gr. H U W z w > `� z a Q m z o z a o x ° oa > SUB -BASEMENT B A S E M ENT 1 t 1ST. FLOOR 2ND . FLOOR 1 3RD . FLOOR 4TH . FLOOR 5TH . FLOOR 6TH . FLOOR 7TH . FLOOR 8TH . FLOOR —iE— (Print or f _ p Che Corp.Certificake �Installing Company Name Cti�-t�\\`Y\ ► ea \v 'T 'yT� .-2 Address `C-- Partner. � Business Telephone D'� '� Firm/Co. Name of Licensed Plumber or Gas Fitter "A INSURANCE COVERAGE Check on 1 have a current liability insurance policy or it's substantial equivalent. Yes �_ No If you have checked es please indicate the type coverage by checking theappropriate box. D Liability insurance policy 0_ Other type of indemnity Bond Owner's Insurance Waiver: I am aware that the licensee does not have the Insurance coverage required by Chapter 142 of the Mass.General Laws,and that my signature on this permit application waives this requirement. Check one: Signature of Owner or Owner's Agent Owner 13 Agent 13 I hereby certify that all of the details and information 1 have submitted(or entered)in above application are nd accurate to the best of my knowledge and that all plumbing work and installations performed under Permit Issued forgri's-applipAtion will be in compliance with all pertinent provisions of the Massachusetts St to Code and Chapt r 1 of a Ge By: gnature of Licensed PI er Or as Fitter Title Plumber �3 d cy C,) City/Town D Gas Fitter icense Number ®aster APPROVED(OFFICE USE ONLY) D Journeyman Location , . No. o� _ Date 5 * � o 2E MOR7M TOWN OF NORTH ANDOVER, O? •' • Oow N p Certificate of Occupancy $ Building/Frame Permit Fee $ cwuSEt Foundation Permit Fee $ `~ "WV ermit Fee $ tt'�' Sewer Connection Fee $ �o Water Connection Fee $ TOTAL $ �S • r� Ods c:) Building Insp or ' - n v Div. Public Works Location 7 No. 5z:3 Date t Z 1 fi 14ORTN TOWN OF NORTH ANDOVER 0 "ISO A Certificate of Occupancy $ 4 ; : Building/Frame Permit Fee Foundation Permit Fee $ s�CMusa Other Permit Fee $ `— 't Sewer Connection Fee $ Water Connection Fee $ i TOTAL $ � 4 t ' ( �C Building Inspector w . 12/11/95 13:41 1,044.00 PAID - 9284 Div. Public Works Loction (422 :3C 5S ,. ST No � �Z� Date S NORTq TOWN OF 'NORTH ANDOVER O:tt a o 1h00L ` p Certificate of Occupancy $ # o Building/Frame Permit Fee $ ,SSACNUSEt� Foundation Permit Fee $ Other Permit Fee $ Sewer Connection Fee $ Water Connection Fee $ TOTAL $ Building Inspector 14/24/95 12:00 154.00 PAID 9233 Div. Public Works t _ _ F / Location i oNo. Date 0-1�- �aRTM -TOWN OF NORTH ANDOVER 3?0�,,,.° oL I p Certificate of Occupancy $ Building/Frame Permit Fee $ Foundation Permit Fee $ 1 SACMusE f Other Permit Fee $ 6 Sewer Connection Fee $ q � - 53Z Water Connection Fee $ 7, D a TOTAL $ (cy l 3 � �3 �ui ing 1 e or v J D' . blic Works - PER]HIT NO. J�Z, t APPLICATION FOR PERMIT TO BUILD - NORTH ANDOVER, MASS. PAGE I MAP 4d0. LOT NO. 16 2 RECORD OF OWNERSHIP DATE (BOOK PAGE ZONE R�Z SUB DIV. LOT NO. um �p I (q t� LOCATION to 5 •-Ba SL , PURPOSE OF BUILDING 7f-lm .lW �45�c V /C • - OWNER'S NAME kA D n� � UK/`_C� �i -- NO. OF STORIES Z - SIZE 2-?)c3 y' IbK2© OWNER'S ADDRESS S�m BASEMENT OR SLAB ► ARCHITECT'S NAME 'fit SIZE OF FLOOR TIMBERS IST `fv 2ND 3RD BUILDER'S NAME ,VV J/, ogeW `C/S SPAN i- C C� ( --- DISTANCE TO NEAREST BUILDING DIMENSIONS OF SILLS --- DISTANCE FROM STREET Y O["O�l°'P''1 .. 3 h: POSTS L4-11 LC (a DISTANCE FROM LOT LINES-SIDES 1 30-+ REAR "{� "/_x l r-71 GIRDERS �7 AREA OF LOT � Vy FRONTAGE)/ © HEIGHT OF FOUNDATION p r THICKNESS IS BUILDING NEW y +C SIZE OF FOOTING Q2 X 1 IS BUILDING ADDITION jj /-/a MATERIAL OF CHIMNEY I/S` /ly IS BUILDING ALTERATION 41 IS BUILDING ON SOLID OR FILLED LAND WILL BUILDING CONFORM TO REQUIREMENTS OF CODE y'CS IS BUILDING CONNECTED TO TOWN WATER BOARD OF APPEALS ACTION. IF ANY IS BUILDING CONNECTED TO TOWN SEWER MCI IS BUILDING CONNECTED TO NATURAL GAS LINE 3 PROPERTY INFORMATION • INSTRUCTIONS PERMIT FOR FOUNDATION ONLY p B.C. LAND COST 9,f jOQO �+ SEE BOTH SIDES REGULATED BY PARA. 114.0'. C _EST. BLDG. COST ly�0 7 EST. BLDG. COST PER SQ. FT. Y L�� OQ PAGE 1 FILL OUT SECTIONS 1 - 3 EST. BLDG. COST PER ROOM PAGE 2 FILL OUT SECTIONS 1 - 12 DATE Lb FEE PAID too -SEPTIC PERMIT NO. + ELECTRIC METEPS MUST BE ON OUTSIDE OF BUILDING 4 APPROVED BY ATTACHED GARAGES MUST CONFORM TO STATE FIRE REGULATIONS _. PLANS MUST BE FILED tACN�D APPROVED BY BUILDING INSPECTOR ATE FLED +0 ` ` ` BUILDING INSPECTOR SIGNATURE OF OWNAA OR AUTHORIZED AGENT -'7 u FEE l PERMIT E ING OWNER TEL.# l(1 PERMIT GRANTED EEE PAID- CONTR. i CONTR.TEL.# Cx 1ALL - _ DATE: ok 057/CONTR.LIC.# �+ H.I.C.# OCT 10 $qcb(p L'I M3 31x3 a BUILDING RECORD 1 OCCUPANCY 12 SINGLE FAMILY RIES THIS SECTION MUST SHOW EXACT DIMENSIONS OF LOT AND DISTANCE FROM MULTI. FAMILY _ OFFICES LOT LINES AND EXACT DIMENSIONS OF BUILDINGS. WITH PORCHES. GA- APARTMENTS RAGES. ETC. SUPERIMPOSED. THIS REPLACES PLOT PLAN. CONSTRUCTION 2 FOUNDATION _ 8 INTERIOR FINISH CONCRETE 00, d 1 2 13 CONCRETE BL K. PINE _ BRICK OR STONE HARDW D PIERS PLASTER _ DRY WALL _ UNFIN. 3 BASEMENT Lol AREA FULL FIN. B'M'T' AREA _ 1/1 1/I '/ FIN. ATTIC AREA _ NO BMT FIRE PLACES HEAD ROOM MODERN KITCHEN 4 WALLS I 9 FLOORS CLAPBOARDS B 1 2 3 DROP SIDING CONCRETE �_ WOOD SHINGLES EARTH _ ASPHALT SIDING HARDW'D _ ASBESTOS SIDING COMMON _ VERT. SIDING ASPH. TILE _ STUCCO ON MASONRY STUCCO ON FRAME BRICK N MASONRY ATTIC STRS. & FLOOR _ BRICK ON FRAME CONC. OR CINDER BLK. STONE ON MASONRY WIRING STONE ON FRAME / SUPERIORPOOR _ ADEQUATE NONE 5 ROOF 10 PLUMBING GABLE I HIP BATH (3 FIX.) GAMBREL MANSARD TOILET RM. 12 FIX.) FLAT SHED WATER CLOSET _ ASPHALT SHINGLES Loe LAVATORY _ WOOD SHINGES KITCHEN SINK SLATE NO PLUMBING _ TAR 8 GRAVEL STALL SHOWER _ ROLL ROOFING I MODERN FIXTURES ' TILE FLOOR TILE DADO 6 FRAMING 11 HEATING WOOD JOIST PIPELESS FURNACE FORCED HOT AIR FURN. TIMBER BMS. &COLS. STEAM STEEL BMS. & COLS. HOT W'T'R OR VAPOR - - -. WOOD RAFTERS AIR CONDITIONING RADIANT H'T'G UNIT HEATERS 7 NO. OF ROOMS GAS OIL •`�"a� '�-' ."r"",r..'•,:.Af L:.,...,d1J r'_., B'M'T 12nd I ELECTRIC }y} 3rd NO HEATING NORTI-r T0VM of over 'f .r No. 5V 0 '' Qsinem W 1911s- � o - ,�1`�r dower, Mass., coc„C�E11 CK a ADRATED 1 15 BOARD OF HEALTH Food/Kitchen PERMIT T Septic System BUILDING INSPECTOR THIS CERTIFIES THAT.A'.'��..4.... 1A tatVD 22 .. .......................................................... Foundation has permission to erectO.CM...FV A,h1E, buildings on Cpm..."R ......�.............••............•.......... ROLIgh to be occupied asS�.tt` t ...�7�1fisll!rl- S ew. a. ..... Z 4 .AQ,+...`��Q��........................ Chimney shallhi eve res ectdonform to the terms of thea lication on fileinprovided that the personacceptingtevery p PP Final this office, and to the provisions of the Codes and By-Laws relating to the Inspection, Alteration and Construction of Buildings In the Town of North Andover. PERMIT FOR FOUNDATION ONLY PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. REGULATED BY PARA. 114.8-S. B.C. Rough • PERMIT EXPIRES IN 6 M�1� Final FEE PAID______ UNLESS CONS U ST RT ELECTRICAL INSPECTOR Rough ..... ........ ............. ............ Service BUILDING 1 ECTOR Final Occupancy Permit Required to Occupy Building AS INSPE oR — . <C h Q`O Display in a Conspicuous Place on the Premises Do Not Remove Q �,§" Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building Inspector. �;. Burner Street No. Smoke Det. eR4Z -- q.2£_�3 FORM U - LOT RELEASE FORM INSTRUCTIONS: This form is used to verify that all necessary approvals/permits from Boards and Departments having jurisdiction have been obtained. This does not relieve the applicant and/or landowner from compliance with any applicable local or state law, regulations or requirements. ****************Applicant fills �+out / this section***************** APPLICANT: ,���, A(L"A ,oL4 I �1, Phone LOCATION: Assessor's Map Number Parcel 10 Subdivision m,►� A Lots) � !o Street Z75-k.'+'l �" St. Number 4P5 ************************Official Use Only************************ RECOMMENDATYOF TO AGENTS: Date Approved A//1 JS' Conservation Admin strat r (' LDate eje ed Gr1f -f W F�kw �1 • J SComments 1100 k. � �,v 4 � 721tr,�A 41 ell S NI W0*4s W144 - Date Approved C) Town Planner Date Rejected Comments Date Approved Food Inspector-Health Date Rejected _LJ �2 A_.) Date Approved Septic Inspector-Health Date Rejected Comments Public Works - sewer/water connections -Z-� /D- - driveway permit (Tl c) fp-/Q Fire Department G �O�X�✓ d eceived by Building Inspector Date OCT i 9 CERTIFIeV PLOT PLAN ; LOCATED IN NORTH ANDOVER, MA. SCALE:1"=40' DATE:11/25/95 Scott L. Giles, R.P.L.S. 50 Deer Meadow Road .North Andover, Mass. 150 Ods r LOT 16 44,992 S.F. (3 o_ 64 _ -- �,O V�:107.9 94 SN Res-, SO p,0 ON S I CERTIFY THAT OFFSETS SHOWN ARE FOR THE USE THE OFFSETS OF THE BU%DING INSPECTOR ONLY SHOWN COMPLY AND SUCH USI=IS FOR THE 8 1 ES H WITH THE ZONINGc,�, • 139BY LAWS OF 72 0 DETERMINATION OF ZONING `� �F6/StEREo � NORTH ANDOVER, MA. CONFORMITY OR NON-CONFO .ITY �4t tAIM WHEN BUILT WHEN OONSTRUCTED: 11/2 5 ORT o 120 Main Street 01845 Director Town of NORTH ANDOVER BUILDING CONSERVATION se�c.09c4 DIVISION OF PLANNING PLANNING & COMMUNITY DEVELOPMENT CHIMNEY APPLICATION AND PERMIT ' DATE - _-z �� PERMIT # a �� LOCATION 6-5-- /3 6�(p/i- S OWNER'S NAME BUILDER'S NAME tri d rG /Q1 l2 2 d- MASON'S NAME �z /If/a/C,/C/-)`�2 Z<, MASON'S ADDRESS /5- 3 MASON'S TELEPHONE ?1Z-)7 MATERIAL OF CHIMNEY / ) , INTERIOR CHIMNEYZ:� EXTERIOR CHIMNEY NUMBER AND SIZE OF FLUES THICKNESS OF HEARTH will chimney or fireplace conform to requirements of the code and have rules and regulations been received: DATE. A— �k- SIGNATURE OF MASON � CONTR. LIC. # �S o�zSzl EST. CONSTRUCTION COST/CONT//RACT PRICE PERMIT GRANTED d _UZ"-gb FEE 2-5 e' ) ROBERT NICETTA, BUILDING INSPECTOR INSPECTED REMARKS SOLID BRICK REQUIRED THIS PERMIT MUST BE DISPLAYED ON THE PREMISES F i S77 CERTIFICATE OF USE & OCCUPANCY Town of North Andover Building Permit Number 527 (1995) Date OCTOBER 29,_1996 THIS CERTIFIES THAT THE BUILDING LOCATED ON 65 BOSTON STRFF P MAY BE OCCUPIED AS S.F. DWM, JNG W/2 CAR GARAGE IN ACCORDANCE WITH THE PROVISIONS OF THE MASSACHUSETTS STATE BUILDING CODE AND SUCH OTHER REGULATIONS AS MAY APPLY. CERTIFICATE ISSUED TO Andrew & Maurice Bldrs. 369 Merrimack St. ADDRESS _ Methuen, MA jP `"use Building Inspector r NORTH F Town of--- dover r zi No. 5 2.'T O ¢_ dover, Mass.,©ate—M ?A 19,R5 l COCMICMEwKK ORATED P9�`�.(5 BOARD OF HEALTH PERMIT TFood/Kitchen /) Septic System-J> a/L6 A BUILDING INSPECTOR THIS CERTIFIES THAT./ ..4.... t�ILD ¢. .. :........................................................ Eounjdadohas permission to erect ?...�Q)E. buildings on �p, ................ 1` ......•�..................................... to be occupied as�t Cl .. 4.ty1.l. . ft"a..... , ..CIS....64P*6�........................ Chimney ey provided that the person accepting this permit shall in every respect onform to the terms of the application on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection, Alteration and Construction of l l� Buildings in the Town of North Andover. PERMIT FOR FOUNDATION ONLY PLUMB G INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. REGULATED BY PARA. 114.8-S. B.C. . EXPIRES IN 6 M PERMIT E FEE PAID m — ELEC CAL INSP R ui�olNc CONS U T T PERMIT FOR FRAME/BUILDING ............... rice- t "-FEE PAID' t0�44 ^ BUILDING ECTOR ;t;n-v �� 'y DATE.—? - Occupancy Permit Required to Occupy Building GAS INSPECTOR Display in a Conspicuous Place on the Premises — Do Not Remove Rough IVIA P Y P Final No Lathing or Dry Wall To Be Done FIRE DEPARX' ) Until Inspected and Approved b the Building Inspector.p P P Y 9 P Burner a Street No. ` � '� G"l 1 Smoke Det. l AZ t-i�--CD.t� �i 2�f���L+ C fir' l� -r � • 4=' ���- �.-�-�'� � i i I i _ � r s �kORTF1 Ot, 1O ' 1'ti0 N p NORTH ANDOVER BUILDING DEPARTMENT �,S•..o �;� 400 Osgood Street SwCHUs Tel: 978-688-9545 Fax: 978-688-9542 BUSINESS FORM FOR TOWN CLERK DATE: FFO NAME: ER L T K/U ES-- 7 ' ADDRESS: �� r TO ST A)06 / ZONING DISTRICT: 2 TYPE OF BUSINESS: N S TAN C� BUILDING LAYOUT PROVIDED: YES NO ` AVAILABLE PARKING SPACES: ZONING BY LAW USAGE: YES NO T BUILDING INSPECTOR SIGNATURE Revised 11.5.04 BUSMSS FORM FOR TOWN CLERK .INSTALLATION U �. ® L MANUAL W U@ L for the MAJESTIC. c MODELS: R36A/RC36A M R42A/M RC 42A Factory Built Fireplaces Non-Circulating Circulating I IMPORTANT: Read all instructions carefully before starting installation. Failure to follow F' these installation instructions may result in a possible fire hazard and will void the MAJESTIC warranty. Save this manual for future reference. For Use In ' U � W M�1 ESTIC Copyright Majestic 1995 NON-CIRCULATING FLUE COLLAR OUTER COLLAR FLUE DAMPE STANDOFFS SCREEN (2 PROVIDED BRICK SIDES AND BACK AIR INLET(EACH SIDE) SURROUND—, -OUTSIDE AIR ACCESS COVER (RIGHT SIDE ONLY--MR Series) NAILING FLANG (LEFT SIDE ONLY--R Series) (2 PROVIDED) FLUE DAMPER CONTROL GAS LINE ACCESS HOLE HEARTH (BOTH SIDES) FIREBOX GRATE METAL SAFETY STRIP(S) NOTE: Nailing flanges are provided SHOWN NOT IN PLACE on hearth for optional use. (1,2,OR 3 PIECES) 616-1 a CIRCULATING FLUE COLLAR OUTER COLLAR FLUE DAMPER SCREEN STANDOFFS (2 PROVIDED) /BRICK SIDES AND BACK ELECTRICAL ACCESS /(RIGHT SIDE ONLY) SURROUND AIR INLET(EACH SIDE) _OUTSIDE AIR ACCESS COVER NAILING FLANGE---go, (RIGHT SIDE ONLY--MR Series) (2 PROVIDED) (LEFT SIDE ONLY--R Series) FLUE DAMPER CONTROL GAS LINE ACCESS HOLE HEARTH (BOTH SIDES) FIREBOX GRATE METAL SAFETY STRIP(S) NOTE: Nailing-flanges are provided SHOWN NOT IN PLACE on hearth for optional use. (1,2,OR 3 PIECES) 616-1b Fig. 1. Parts of the MAJESTIC Non-Circulating and Circulating Models. Table of Contents Page Identification of Parts 2 Installation Precautions 3 Installation Instructions 3 Reference Data 14 Accessory Parts 16 2 INSTALLATION PRECAUTIONS A-2. DETERMINE FIREPLACE LOCATION. This MAJESTIC Fireplace and its components have been The fireplace can be mounted on any of the following tested and will operate safely when installed in accordance surfaces: with this Installation Manual. Read all instructions before 1) A fiat combustible (burnable)surface. starting installation,then follow these instructions carefully 2) A raised wooden platform. during installation to insure maximum fireplace benefit and 3) n four l 4)Fo corners (4) of thconce fireplace. te asonry blocks.) safety. Report to your dealer any parts damaged in shipment. These supports must be positioned so they contact the Since this fireplace and chimney assembly is a highly perimeter edges on the bottom of the unit. engineered system,unless you use components which have The fireplace must be spaced 3/4 inch from a combustible been designed for the system,you may possibly cause a fire back wall and 7/16 inch from a combustible side wall. - hazard. Nearby combustible floors and walls must be protected as The MAJESTIC warranty will be voided by,and detailed in Section H. MAJESTIC disclaims any responsibility for the following Refer to Air Space Data and Dimensions on pages 14 and 15 actions: to be sure that the location which you have selected for your • Installation of any damaged fireplace or chimney fireplace provides for clearance and framing restrictions. component; At this point you should have decided what components to • modification of the fireplace,chimney assembly or include in your installation,where the fireplace is to be any of the component parts thereof; (except for chase located, and how the chimney will be routed to the roof flashings as detailed in Majestic Chimney Top installation (straight-up,offset,or chase*). If this has not been done,stop instructions). and consult your Majestic Dealer for assistance with this • Installation other than as instructed by MAJESTIC; planning. or *A chase is a vertical box-like structure which encloses the • Installation and/or use of any component part not fireplace and/or its chimney,typically built on the outside of manufactured or approved by MAJESTIC in combina- the house with the fireplace opening cut in the outer wall of tion or assembly with a MAJESTIC fireplace system, the home. notwithstanding any independent testing laboratory or other third party approval of such component parts or accessory. LT MODEL SK8 DIMENSIONS Any such action may possibly cause a fire hazard. „ 2 WALL CHIMNEY IN INCHES MODEL TOTAL iINSTALLED Consult your local building codes. L NO. LENGTH(LTA LENGTH(LI) Ll ............................................. This fireplace and chimney system must be vented out-of- SK81��������;� 11-1/2 10-1/2 doors. ......s 17-1/2 16-1/2 SK83 L 35.1/2 34-1/2 Do not obstruct or modify air inlets/outlets in any I SK84 ? 47-1/2 i 46-1/2 manner.(See page 11.) Do not install combustible materials onto the black fireplace surround. Fig. 2. Installed lengths of chimney sections. Burn solid wood fuel only. Note that the installed length of any chimney section is less Do not install a fireplace insert or other products not than its s total length (except ifor the last section installed), specified for use with this fireplace. The MR42AIR36A and MRC42A/RC36A units are not A-3. INSTALL METAL SAFETY STRIPS approved for installation in mobile homes UNDER FIREPLACE. When installing Model SK8,2-Wall Chimney System,a 1 See Step G, Insulating Fireplace Enclosure for Cold inch minimum thickness of Majestic EH2416 Hearth Climates, before completing Step A-3. Extension Material or equivalent , MUST be used(see Thoroughly clean intended fireplace location area. Move Step H-5). fireplace to the location where it is going to be installed. Lift When installing Model S,3-Wall.Chimney System,a 1/2 fireplace front slightly to slide metal safety strip(s)under front inch minimum thickness of Majestic EH2416 Hearth bottom edge about 1-1/2 inches, allowing the remainder to Extension Material or equivalent,can be used(see Step extend out in front of the fireplace.Overlap the strips at least H-5) 1/2 inch to provide a positive joint. (See Fig.3.) (Flat safety ' Manual for operating strips are packed with fireplace.)_ _ Prior to first firing, read Owners Man p 9 I In the event the fireplace is elevated above the floor, a"Z"- instructions. shaped metal safety strip should be fabricated and used to INSTALLATION INSTRUCTIONS protect combustible surfaces in front of the fireplace.This 7'- A. Installing the Fireplace shaped safety strip is not provided,but must be fabricated of metal with each horizontal leg at least 1-1/2 inches wide— A-1. CHECK HOW ACCESSORIES ARE equal in length to the metal strips provided with each INSTALLED. fireplace. Determine where selected accessories fit into this fireplace When positioning the fireplace on all mounting surfaces(see installation procedure by checking the installation Step A-2),the metal safety strips must be installed as instructions provided with each accessory. See Accessory described above to provide protection to combustibles Parts, page 16. (burnable)surfaces in front of the fireplace. NOTE:The outside air system or electrical junction box NOTE: Safety strip is not required over non-combustible wiring for circulating models cannot be installed after the floors where all supports at the base of the fireplace are non- fireplace is installed. combustible. 3 from that wall and make a mark on the ceiling above the fireplace. Draw a line through this mark parallel to the back / wall,defining the centerline of the chimney. (See Fig.5.)Then, ,✓vz" MIN. using a plumb bob positioned directly over the center point of rthe fireplace flue collar, mark the ceiling to establish the chimney centerpoint. (See Fig. 5.) B-2. LOCATE CENTERPOINT OF CHIMNEY- ,� METAL SAFETY STRIPS OFFSET INSTALLATION. - �11h1, (1, 2 or 3 PIECES) In order to clear an obstruction, it may be necessary to offset 11/2" the chimney from the vertical plane.This is done by using SPECIAL'2" Majestic Chimney Elbows: Model SK830(300). Each offset METAL requires a pair of elbows. Use Table 1 and Fig. 6 to determine SAFETY STRIP the offset that may be obtained using the various elbows. 11/z" I Table 1:Offset dimensions. Fig. 3. Install metal strip(s) under front of fireplace. DIMENSIONS A-4. ANCHOR FIREPLACE IN POSITION. T S SK830 SK830 To prevent shifting of fireplace and maintain sealing(described No Intermediate Section 0'3" 0111" later),anchor the fireplace. Use side nailing flanges shipped on fireplace hearth to secure fireplace to vertical framing One 1'Section 0'8-1/4 118" members. (See Fig.4.) Refer to Framing and Finishing Section One 1-1/2'Section 0' 11-1/4" 2' 1-1/4" H. Nialing flanges are installed by loosening surround side screws, inserting flanges and tightening to secure to fireplace. Two 1'Sections 1' 1-1/2" 2'5-1/4" One 1'and 1'4-1/2" 2' 10-1/4" One 1-1/2' Section One 3' Section 1'8-1/4" 3'4-3/4" LING Two 1'and LANGES One 1-1/2'Sections 1'9-3/4!' 3'7-1/2" One 4'Section 2'2-1/4" 4'3-1/4" NAILS OR OTHER SUITABLE One 3' and 2'4-1/4" 4'7-1/4" FASTENERS One 1-1/2' Section One 1'and 2'7-1/2" 5'0-1/4" �7/1\ One 4'Section One 1-1/2'and 2' 10-1/2" 5'5-1/2" One 4'Section Two 3' Sections 3' 1-1/2" 5' 10-3/4" NAIL SIDE CENTERLINE OF N CHIMNEY AILING FLANGES ACTUAL CENTERPOINT Fig. 4. Fasten fireplace in position using the nailing 10-3/4" flanges or top standoffs. ` (MR Series) B. Installing the Chimney 10" CAUTION: REPORT TO YOUR DEALER ANY PARTS _ (R Series) DAMAGED IN SHIPMENT, SPECIFICALLY, CHECK THE PLUMB LINE END CONNECTIONS OF CHIMNEY SECTIONS AND - - ELBOWS. NOTE:The MR42A/MRC42A Series fireplace may use Majestic Model SK8 or Majestic Model S, 3-wall chimney PLUMB BOB system.The fireplace accepts the SKS chimney system.A chimney adapter is necessary to attach"S"chimney system. The installation procedure described in Section B(Installing the IMAGINARY Chimney), applies to the SK8 system only. Either system may CENTERPOI be used,but SK8, CF8 and S components may not be mixed. For clarification, refer to the Accessory Secion of this manual beginning on page 16. B-1. LOCATE CENTERPOINT OF CHIMNEY— STRAIGHT UP INSTALLATION. If the fireplace rear spacer is positioned against the wall behind it, measure out 10-3/4 inches for MR Series, 10 for R Series Fig. 5. Locate centerpoint of chimney with plumb line. I 4 FLUE FLUE OUTLET OUTLET b DETAIL 1 CHIMNEY EXIT SUPPORT STRUCTURE ELBOW STRAP cHIMNEI (MUST BE TIGHT) SECTION ELBOW 4 CEILING HOLE FRAMING ETAL 2 MEMBER ANGLE, FIRESTOP CHIMNEY SUPPORT STRAP TRADITIONAL CONTEMPORARY (MUST BE TIGHn CHIMNEY TOP CHIMNEY TOP CHIMNEY DETAIL Z SUPPORT NOTE:X-1-111'MIN.AIR SPACE DETAIL TO COMBUSTIBLES SEE ELBOW OFFSETS CHIMNEY EXIT DETAIL 1 SEE SEE 1' }1R r r dira N. DETAIL 1 DETAI0 0 0 0 0 31 1t' t 0 0 0 0 8-1/t 20' 0 1 0 0 0 11-1/4' 25-t/4' 2 0 0 0 0 13-12' 29-1/4' 1 1 0 0 0 16-12' 34-IW 0 0 1 0 0 20-1/4' 40-3/4' 2 1 0 0 0 21-314' 4312' 0 0 0 1 0 26.1/4' 51-1/4' CHIMNEY 0 1 1 0 0 2812' ss trr SECTION 1 0 0 1 0 31-12- 60-tAr ELBOW g• 0 1 0 1 0 34-12' 65.12' B` 0 0 2 0 0 37-12' 70-3W 1 1 0 1 1 41-12' 77-3N B` C 0 0 1 1 1 4S 8:-314' 0 1 2 0 1 47-1/4' 87-12' G 0 0 0 2 1 51' W ••B G 0 1. 1 1 1 531/4' 98- A 0 0 3 0 1 56-1/4' 1031/4' T 0 1 0 2 1 59-1/4' 108-12' D "B 0 0 2 1 1 82-1/4' 11312' 0 1 3 0 1 64-12' 11712' S 0 0 1 2 1 68.1/4' 124 6 FT 0 1 2 1 1 70-12' 126' C, T 0 0 0 3 1 71-1/4' 134-12' 0. 1 1 2 2 78' 140-3/4' S .B C 0 0 3 1 2 81' 146' T H 0 1 0 3 2 84' 151-1/4' 0 0 2 2 2 8T 156-72- B- S 0 1 3 1 2 89-1/4' 160-1/4' _[� H 0 0 1 3 2 93' 166-314' B» B.. 0 1 2 2 2 95.1/4' 170.314' 0 0 0 4 2 99-1/4' 177-3/1' 0 1 1 3 2 101-1/4' 181-3/4- 0 0 3 2 2 104.1/4' 186-1/4' 0 1 0 4 2 107-1/4' 191-W HEARTH 0 0 2 3 2 110-1/4' 196 34' 0 1 3 2 3 114' 2031/4' FLOOR 0 0 1 4 3 117-314' 209-314 I ]j 0 1 2 3 3 120' 21312' NOTE:G+H CANNOT EXCEED 20' 0 0 o s 3 1233/a- 220' Fig. 6. Typical offset installations. The following safety rules apply to offset installations. (The B. D not use the more than four aps of the top elbows p r ahimne structural letters below match the letters in Fig. 6.) A. Height of the chimney measured from the hearth to the framing member. chimney exit at top. ''"'The first elbow of any pair does not have straps. R36A/RC36A C. The chimney cannot be more than 300 from the vertical plane. Maximum: 90 Feet D. The maximum length of the angled run of the total Minimum: chimney system is 20 feet. (G plus H cannot exceed 20 Without Elbows 12 Ft. 6 In. feet.) With 2 Elbows 12 Ft. 6 In. E. A chimney support(Model SKCS8)is required every 6 feet of angled run of chimney.Chimney supports are With 4 Elbows 16 Ft. 0 In. required at 30 foot and 60 foot of chimney heights MR42A/MRC42A measured from the hearth. Maximum: 90 Feet Determine the offset distance of your chimney arrangement from the centerline of the fireplace to the centerline of the Minimum: chimney where it is to pass through the first ceiling. NOTE: Without Elbows 14 Ft.0 In. This offset distance may not be your full offset distance (T). With 2 Elbows 15 Ft. 6 In. (See above.) With 4 Elbows 21 Ft. 0 In. 5 Locate on the ceiling the centerpoint of the chimney, as 14-1/2^ I 14-1/2^ though a straight up chimney arrangement is to be used,by l dure outlined in -1.Then measure ''` followingthe proce Step B your offset dimension from the straight up chimney "<::,I CHIMNEY HOLE centerpoint on the ceiling. (See Fig.7.) OFFSET CENTERPOINT OFFSET CENTERLINE / STRAIGHT UP CENTERPOINT CHIMNEY CENTERLINE CEILING I OFFSET NEW FRAMING 10-3141' DIMENSION MEMBERS (MRSries) ` 10" r EXISTING CEILING JOISTS— . (R Seles) Fig. 8. Typical frame for ceiling chimney hole. B-6. INSTALL FIRESTOP SPACER. . Firestop spacers are required for safety.The hole sizes listed in Table 2 for angled Firestop spacers provide the minimum required air space to the chimney pipe for ceiling thicknesses up to 8 inches.When the combined thickness of the ceiling material,ceiling joists and flooring material exceeds 8 inches, adjustments must be made in the framing to assure that the minimum air spaces to the chimney are maintained. If the area above the ceiling is not an attic, position the firestop spacer with the flange on the ceiling side and the Fig. 7. Measure first ceiling offset distance from straight angled portion extending up into the hole. In the US, if the area above the ceiling is an attic, position the firestop spacer up centerpoint. with the flange on the top of the framed hole and the angled B-3. MARK AREA OF CEILING CHIMNEY portion extending down into the hole. (See Figs. 9 &10.) In HOLE. Canada an attic insulation shield MUST be installed if the area above the ceiling is an attic. Use Majestic Attic with the angle The size of the ceiling chimney hole will vary g Insulation Shield Model AIS-SK. the chimney at which y passes through the ceiling. Refer to Table 2: Nail each corner of the Firestop spacer to the framing Drive a nail up through the ceiling at the marked chimney members of the ceiling hole. NOTE:A firestop spacer is not centerpoint. Go to the floor above and check where the hole required at the roof. will be cut, relative to the ceiling joists and any obstructions Table 3: Firestop model numbers. such as wiring or plumbing runs. If necessary,re-position the TYPE FLUE TYPE OF SPACER MODEL NO. chimney and/or the fireplace to better accommodate these joists and/or obstructions. 8"Straight Dished SKFS2A B-4. CUT CEILING CHIMNEY HOLE. 8"30°Inclined Angled SKFS6A After covering the opening of the fireplace collar, cut the JOIST chimney hole through the ceiling. Recheck the hole to be sure that it measures the hole size selected from Table 2. The"SK8"chimney allows for framing the chimney hole in a typical 16"on center joist condition without cutting joists. (See Fig. 8.) N�\ B-5. FRAME CEILING CHIMNEY HOLE. Frame the ceiling chimney hole as shown in Fig.8.It is good practice to use framing lumber that is the same size as the ceiling joists. (This is a requirement at the attic level.) The inside dimension of the frame must be the same as the hole size selected from Table 2 in order to provide the CEILING required 11/2 inch air space between the outside diameter of the chimney and the edges of the framed ceiling hole. DISHED FIRESTOP (FIRESTOP SPACER) Table 2: Sizes of ceiling chimney hole. Size of Angle of chimney at ceiling NAILS 4 R ui Chimney Vertical 30° 8"Flue 141/2 x 14112 141/2 x 251/2 Fig. 9: Position of firestop when area above ceiling is not an attic. 6 NAILS(4 Required) JOIST _ HEM PIPE SECTION] BUILT-IN SNAP-LOCK FASTENER uP LANCE FIRESTOP SPACER ~ Fig. 10. Position of firestop when area above ceiling is an attic. B-6-1.INSTALLING ATTIC INSULATION SHIELD. (CANADA) The attic insulation shield is required for safety to prevent attic insulation from contacting the chimney section.The framing dimensions for the chimney hole should measure Fig. 11. Use built-in snap-lock fasteners to attach 14-1/2"x 14-1/2".The attic insulation shield MUST be installed on top of the attic joists(above floor joist level). (See chimney pipe sections. Fig. 10a.) Install the attic insulation shield with the flanges on its base extending down into the framing hole. (See Fig. 10a.) Nail each corner of the attic insulation shield to the framing CHIMNEY SECTION BEAD MUST MAKE members of the ceiling hole using 8d nails. CONTACT WITH FRAMING MEMBER NOTE:A firestop or attic insulation shield are not required at AHAMMEPROALL the roof. STRAPS INTO WOOD BEFOREINSTALLING FIRESTOP ANGLE ATTIC INSULATION SHIELD CEILING HOLE FIRESTOP FRAMING NAILS MEMBER (4 REQUIRED) ~ '� I I I I I X CHIMNEY SUPPORT SMUST Bt TIGHT) I I T I I CHIMNEYSUPPORT ASE FLANGE CEILING ATTIC JOIST ATTIC ABOVE 488-10.dxf CHIMNEY SECTIO Fig. 10a. Installing attic insulation shield. (CANADA) PROVIDE SLOTTED B-7. ATTACH CHIMNEY SECTIONS HOLE FOR STRAP ENTRY-DO NOT Attach the first straight chimney section to the fireplace collar, CUT F RE8TOP IN or elbow if offset installation. (Refer to Step B-8.) Mount the CEILING HOLE 1 � FRAMING flue pipe first, using the built-in snap-lock fasteners. (See Fig. MEMBER 11.)Then mount the additional pipe. Position each pipe X section so the direction arrow is pointing UP. Make sure each pipe is firmly snapped and locked " r together as it is mounted. Continue installing chimney sections until ONE SECTION (all BEAD-MUST MAKE i es extends u through the ceiling hole.To extend through CONTACT WITH pipes) P 9 9 g CEILINGATALL the ceiling, it may be necessary to assemble all pipes, push POINTS them up through the ceiling hole and then slide them down ANGLE FIRESTOP one at a time to connect them. S IIMMPE((/YYSL PPORT B-8. ATTACH FIRST ELBOW- OFFSET MUSTBETIGHT) INSTALLATION. NOTE:-1-1R-MIN.AIR SPACE CHIMNEY SUPPORT If the first elbow is not to be attached to the fireplace, install TO COMBUSTIBLES chimney sections as required. NO ATTIC ABOVE Attach first elbow where required. Note that only the outer pipe snap-locks. Fig. 12. Mount chimney supports at ceiling hole frames Attach the straps of all upper elbows to a structural framing or other structural framing. member. (See Fig. 6.) 7 B-9. DETERMINE HOW MANY CHIMNEY WARNING: DO NOT PACK REQUIRED AIR SPACES SUPPORTS ARE NEEDED. WITH INSULATION OR OTHER MATERIALS. The chimney system is supported by the fireplace for (Combustible surfaces include such things as ceiling chimney heights less than 30 feet of vertical height above the members,joists,flooring,combustible insulation and roof hearth. Chimney supports are required if the chimney height structures.) exceeds 30 feet. Locate chimney supports at ceiling holes or Mark the outline of the roof hole around the centerpoint nail. other structural framing at 30 foot heights. Spacing between Note:The hole dimensions given in the chimney top chimney supports must not exceed 30 feet. Use Majestic installation instructions are horizontal dimensions;therefore, Chimney Support Model SKCS8. (NOTE:The SKCS8 can the hole size must be marked on the roof accordingly. not be mounted directly to the fireplace.)Support provided Cover the opening of the installed chimney. by elbow straps fulfills the support requirement only if they Cut and frame the hole. It is good practice to use framing are spaced as required above. lumber that is the same size as the rafters. Install frame Angled chimney runs require support every 6 feet in addition securely. Chimney top and flashing anchored to frame to the elbow straps. Majestic Chimney Supports are used for .this function. must withstand heavy winds. Refer to Step B-2 to determine how many chimney supports C-3. DETERMINE MINIMUM CHIMNEY HEIGHT are needed and where they will be placed in the chimney run. ABOVE ROOF. NOTE:A chimney support is 2-1/2 inches Ion when Major U.S. building codes specify minimum chimney height installed.This dimension must be considered when above the roof top.These specifications are summarized in determining how many straight chimney sections are needed the Ten Foot Rule. (See Fig. 13.)The key points of this rule to provide the desired offset. are: B-10. INSTALL CHIMNEY SUPPORTS 1. If the horizontal distance from the center of the chimney to the peak of the roof is 10 feet or less,the top of the Chimney supports are attached to chimney sections the chimney must be at least 2 feet above the peak of the roof, same way elbows are attached. Refer to Step B-8.Nail the but never less than 3 feet in height above the highest point chimney support straps to adjacent structural framing, as where it passes through the roof. shown in Fig. 12. Bend the straps as necessary and make 2. If a horizontal distance from the center of the chimney to sure they are tight so they will be able to support the weight the peak of the roof is more than 10 feet, a chimney height of the chimney. reference point is established that is on the surface of the B-11. LOCATE CENTERPOINT OF NEXT CEILING roof a distance of 10 feet from the center of the chimney in a HOLE. horizontal plane. (See Fig. 13.)The top of the chimney must NOTE: If there is no other ceiling,you have completed be at least 2 feet above this reference point, but never less Section B. Proceed to Section C, Penetrating the Roof. than 3 feet in height above the highest point where it passes In a manner similar to that used in Steps B-1 and B-2, mark through the roof. the centerpoint of the next ceiling hole. These chimney heights are necessary in the interest of B-12. PREPARE SECOND CEILING HOLE. safety and do not assure a smoke-free operation. Repeat Step B-3. Mark area of ceiling chimney hole; B-4,Cut C-4. INSTALL REMAINDER OF CHIMNEY ceiling chimney hole; B-5, Frame ceiling chimney hole; and SECTIONS. B-6, Install firestop spacer. Continue installing chimney sections-up'through the roof B-13. CONTINUE INSTALLING CHIMNEY hole.Check your chimney top installation instructions for data SECTIONS. on how high above the roof top the CHIMNEY SECTIONS(all Continue installing chimney sections and chimney supports pipes)should go: (as required), until the chimney passes through the second ceiling hole. *-o'TO 10' NOTE: Repeat Steps B-11 through B-13 as many times as necessary to pass through all the ceilings in the building and bring the chimney just short of the roof. 2'MIN 3'MIN C. Penetrating the Roof The chimney system must be vented out-of-doors and must 2'MIN be terminated with an approved Majestic top termination. _ _ �3'MI N NOTE: If you are using a chase, go to Section D. C-1. LOCATE CHIMNEY CENTERPOINT AT ROOF. Use the same procedure detailed in Steps B-1 and B-2. REFERENCE POINT Drive a nail up through the roof at the marked centerpoint. This will make the centerpoint on the outside of the roof. C-2. CUT AND FRAME ROOF HOLE. Fig. 13.Ten foot rule for chimney height. The size of the roof hole varies with the type of chimney top C-5. INSTALL CHIMNEY TOP HOUSING OR that will be installed. Refer to the installation instructions TERMINATION. provided with your Majestic chimney top termination to find Follow the installation instruction provided with the Majestic the correct size of roof hole for this installation.There must chimney top you have selected. be at least 1-1/2 inch air space between the outermost portion of the chimney sections and any adjacent combustible (burnable)surfaces. 8 D. Installing Chimney in a Chase JUNCTION BOX(JB) WHITE A chase is a vertical box-like structure built to enclose the fireplace and/or its chimney. o ST GROUND o STUD CAUTION:Treatment of firestop spacers and construction of the chase may vary with the type of building. These instruction are not substitutes for the requirements of local building codes.Therefore,your local building codes must be checked to determine the requirements for these steps. BLACK _— NOTE:Other material may be required in addition to Majestic 120 VAC HOUSE WIRIN Firestop Spacers. WIRE NUT 6316-14.dxr When installing a MR42A/MRC42A or R36A/RC36A Series Fig. 14. Wiring diagram. fireplace and chimney in a chase, it is always good building F. Installing Outside Air System 1 practice to insulate the chimney chase as you would an outside wall of your home.See Section G,which describes F-1. INSTALL OUTSIDE AIR KIT. insulation methods Install outside air kit if desired or required by local code. Refer to Framing and Finishing on page 10. Upon completion Refer to AK-MST installation instructions for field installation. of building your chase frame, install the chimney system. This kit MUST be installed before the fireplace is enclosed. Follow the instruction for Installing the Chimney starting on G. Insulating Fireplace Enclosure For Cold page 4.Then proceed to Step D-1. Climates D-1. INSTALL FLASHING AND CHIMNEY TOP. In cold climates, insulation of the enclosure around the Follow the installation instructions provided with the Majestic fireplace is critical to avoid future problems with cold air.The chimney top you have selected. following steps are suggested to eliminate potential cold air E. Install the Electrical Connection (MRC42A problems. or RC36A) G-1. INSULATE BASE OF FIREPLACE. E-1. ELECTRICAL CONNECTION. Insulate the base of the fireplace with a non-combustible CAUTION: ALL WIRING SHALL BE DONE BY A insulation rated for a minimum of 300°F.This step is QUALIFIED ELECTRICIAN AND SHALL BE IN particularly important for outside wall installations over COMPLIANCE WITH ALL LOCAL, CITY AND STATE concrete slab floor construction. If a platform is used to raise BUILDING CODES. the fireplace,the insulation should be placed on top of the platform before the fireplace is set. (See Fig. 15.) IMPORTANT:To prevent electrical shock,the house power must be disabled.This can be accomplished by positioning FLAT,HARD the circuit breaker to off. SURFACE E-2. INSTALLATION OF FIELD WIRING. The fans require 120VAC, 60 Hz power which may be connected to the right side of the fireplace at the electrical junction box which is factory installed in the unit.This power should be provided at initial installation,since access to the / L outer casing is normally not practical at a later date. i Before wiring power to the junction box in the fireplace, remove the cover plate and two (2)mounting screws from the lower right side of the fireplace and set aside. Remove the knockout in'the center of the cover plate. Install Q\ the house power connection to the cover plate using listed ° cable clamps. Feed the house wire through the listed cable clamp leaving approximately 6 inches of wire exposed through the cover plate.Secure the listed cable clamp to the Using pliers, remove the nut from the grounding stud in the - - , junction box and attach the green ground wire from the house i power. Reinstall the nut securely. (See Fig. 14.) INSULATION �r Attach the white wire from house power to one(1)wire of the �Y receptacle and secure within a wire nut.Attach the black wire from the house power to the other wire of the receptacle and PLATFORM secure within a wire nut. (See Fig.14.) IMPORTANT.The wire nuts must be tight. Fig. 15. Insulation between platform and fireplace. Reinstall the cover plate being careful to position the excess G-2. INSPECT JOINTS. wire within the electrical box. Inspect joints of the fireplace as well as the points of sealing NOTE: Refer to optional model SCVS speed control between the fireplace and the finishing materials.Any cracks installation instructions for field installation. should be sealed with non-combustible caulking or insulation. E-3. BLOWER ASSEMBLY. See Fig. 16 for details of sealing spaces between the Refer to optional blower assembly installation instructions for fireplace and finishing materials. field installation. I 9 G-3. INSULATION OF ENCLOSURE. H. Framing and Finishing When a fireplace is installed in a chase or on an outside wall, H-1. DETERMINE WHEN TO INSTALL FRAMING. the enclosure should be insulated like any other wall of the home. Insulation should be installed on the inside wall as Fireplace framing can be built before or after the fireplace is well as the outside wall(s). In a chase, it is also a good idea set in place. Fig. 18 shows the minimum framing dimensions. to install a firestop at the first ceiling level above the fireplace H-2. BUILD FRAMING. and close the chase with sheeting material. Insulation may The fireplace framing should be constructed of 2 x 4 lumber then be installed above the sheeting material to assure the or heavier. Refer to Dimensions on page 15 for basic w space around the fireplace is totally protected.See Fig. 17 fireplace dimensions that will affect the framing dimensions. for additional details of suggested insulating methods. The header may rest on the fireplace standoffs. CAUTION: WHILE INSTALLING A FIREPLACE IN AN Framing should be positioned to accommodate wall covering i INSULATED ENCLOSURE, BE SURE ALL MARKED AIR and fireplace facing material. (See Figs. 19, 20 and 21 for SPACES ARE MAINTAINED. typical arrangements.)Nailing flanges provided on the side of the fireplace can be used to anchor the fireplace. Nail through the flanges into the vertical framing members. (See Fig. 4.) NON-COMBUSTIBLE CAULKING OR INSULATION MODEL MR Series R Series 2 X 4 DIM."A" 48-5/8" 41-7/8" DIM."B" 41-1/4" 37-3/4" DIM."C" 48-5/8" 41-7/8" 2 x 4'S DIM."D" 25-1/4" 22-3/4" •••�" DIM."E" 25-1/4" 22-3/4" STANDOFF FINISHING MATERIAL 7/16' TOP VIEW(RIGHT SIDE) 2 x 4 HEADER Fig. 16. Sealing spaces between fireplace and finishing NAIL SIDE FLANGES materials. INSULATION "B" T INSULATION "A"MIN. "D"MIN. MIN. INSIDE \:2 x 4'S „C„�f FRONT VIEW I TOP VIEW SHEETING MATERIA - Fig. 18. Minimum fireplace enclosure dimensions. CAUTION: All joints between the finished wall and the fireplace surround(top and sides) must be sealed with non-combustible material.Only non-combustible material may be applied as facing to the fireplace surround. I , H-3. FINISH WALL Finish the wall with material of your choice. Do not install a combustible mantel less than 12 inches above the fireplace opening for MR42A and R36A or 12 inches : above grille opening for MRC42A and RC36A. If a combustible material is used below a flat mantel shelf,consult your local building codes for the minimum clearance from the top of the fireplace opening to the bottom of the mantel shelf. All joints(top,bottom and sides),where the wall or decorative facing material meets the fireplace surround must be completely sealed with a non-combustible material. (See Fig. 17. Additional insulating methods. Figs. 19 and 20.) 10 FLAT MANTEL SHELF MRC42A SEEK 2 HEADER HED FOR DIMENSION A, STANDOFFS FINISHED WALL CAUTION: NON-COMBUSTIBLE TOP GRILLE DO NOT PLACE FINISHING DECORATIVE —MATERIAL BEYOND THESE FACING HEARTH EDGES OR COVER GRILLES BOTTOM ON MRC42A FIREPLACE UST BE SEALED GRILLE WITH NON-COMBUSTIBLE MATERIAL 7116" 2 X 4 STUDFINISHED �OQ SIDES SURROUND ALL MR42A CAUTION: MUST BE SEALED DO NOT PLACE FINISHING WITH NON-COMBUSTIBLE MATERIAL BEYOND THESE HEARTH MATERIAL EDGES OR COVER AIR INLETS ON MR42A FIREPLACE Fig. 21. Finishing front of fireplace. FINISHED WALL 40" MIN. Fig. 19. Fireplace surround flush with finished wall. When finishing the fireplace, never obstruct or modify �. the air inlet/outlet grilles in any manner. (See Figs.21.) NOTE: For fireplace installed at 451 to two (2) side walls (corner installation), no side wall protection is required. I �' I I 2 X 4 HEADER I FINISHED WALL FINISHED 40" MIN. UST BE SEALED i WITH NON-COMBUSTIBLE ` MATERIAL STANDOFF NON-COMBUSTIBLE DECORATIV FACING SURROUND FACING NON-COMBUSTIBLE SEALED WITH Z RATIVE INSULATION NON-COMBUSTIBLE NON-COMBUSTIBLE R = 1.85 MIN. MATERIAL RIGID COVERING 'MANVILLE BUILDING SPECIALTIES-EH2416 1 SIDE VIEW THICK) Fig. 20. Facing on fireplace surround flush with finished wall. Fig. 22. Non-combustible wall shield dimensions. H-4. ADD PROTECTION TO SIDE WALLS. H-5. INSTALL HEARTH EXTENSION. Adjacent combustible side walls that are within 21-1/2"of the A hearth extension is required to protect combustible floor ` fireplace openings must be protected with Majestic Wall construction in front of the fireplace. See Fig.23 for minimum Shield Model SP40 or a built up wall shield described in Fig. dimensions and mounting detail. 22. (See Figs. 22 and 23.) (NOTE: Hearth Extension must not cover the grille The built-up wall shield design described in Fig. 22 is an opening of the MRC42A or RC36A.) alternate method for adding protection to side walls and can The hearth extension described in Fig. 23 must be a durable be used in place of the SP40 with the same wall clearances non-combustible material with a minimum(total) RT value of specified for the SP40. RT must= 1.85 minimum. 2.18 when used with Model SK8, 2-Wall Chimney System EXAMPLES OF INSULATION: and the minimum (total) RT value for Model S,3-Wall 1. Manville-CERAFORM 126, K=.27, 1/2"thick Chimeny systems is 1.09 for MR42/MRC42A units. (See required. Table 4 for examples.)The overall height(above combustible 2. Majestic- EH2416, K=.458, 1"thick floor),depth and width must be as indicated,with it centered required. to the fireplace opening. (See Fig. 23.) 11 When installing Model SK8,2-Wall Chimney System,a 1 inch minimum thickness of Majestic EH2416 Hearth COMBUSTIBLE Extensions material or equivalent, MUST be used(see 4"NON-COMBUSTIBL^TOPVIEW MATERIAL Ste H-5 . MATERIALTHIN SHADED PER Step ) EA NOTE:When installing Model CF8,2-Wall chimney or Model S,3-Wall Chimney System,a 1/2 inch minimum thickness of Majestic EH2416 Hearth Extension material � D or equivalent,can be used(see Step H-5). E MINIMUM F C MATERIAL K* R THICKNESS y Majestic 'A A EH2416 0.458 2.18 1.00 in.** MINIMUM _.; g SIDEWALL WITH Common Brick 5.0 0.20 5.46 in. WALL SHIELD COMBUSTIB E SIDEWALL R Value is for one(1)inch PROPOSED * Units of K=BTU/SQ FT/HR/°F/IN PERPENDICULAR SIDE WALLS ** Thickness of Listed Material Table 4: Common materials and their factors. MODEL, A Li c D E F G H 4 A 21-1/2" 18" 40° 33° MR 2 The top Of the insulation must be covered with anon- MRC42A 21-1/2'• 18" a0° 33° 18" 14" 12" 20" 61-1/2" combustible decorative covering or a piece of.018"minimum R3 AA 21-1/2" 12" 40° 33° 18'• 1a" 8" 16 • 48" sheet metal,to protect the hearth extension material. (See RC36A 21.1/2" 12" 40° 33° 18" 14" 8" 16'• 48" Fig. 23.) Secure the hearth extension to the floor to prevent shifting, ---------, using trim molding or other similar means at the three (3) MINIMUM HEARTH O outer edges.Seal the crack between the fireplace hearth and EXTENSION 1 11 the hearth extension with a non-combustible material. (See DIMENSIONS FORrrn ON-SITE G Figs. 23, 24 and 25.) CONSTRUCTION G r� WARNING: HEARTH EXTENSION MUST BE INSTALLED H IN ACCORDANCE WITH FIGS.23,24 AND 25. 1— Alternate, non-combustible materials may be used providing the (total)thermal resistance (RT value) of the alternate SEAL CRACKS BETWEEN material employed is greater than or equal to an R=2.18(SK8 FIREPLACE AND SION WITH EARTH chimney).The thermal resistance (R) or the thermal EXTNON-COMBUSTIBLE MATERIAL conductivity (K) may be obtained from the manufacturer of the material.The factors are related by the formula K=1/R. T=given thickness NON-COMBUSTIBLE DECORATIVE COVERING R=thermal resistance for a given thickness (T) MAY BE INSTALLED OR \SURROUN ER K=thermal conductivity 018"MINIMUM D (FIREPLACE)Non-combustible material with a lower R value may be used, SHEET METALFIREPLACE provided the thickness of the material is sufficiently greater to HEARTH maintain an equivalent total thermal resistance(RT). COMBUSTIBLE EXAMPLE OF DETERMINING HEARTH EXTENSION FLOOR ; EQUIVALENT j To determine the thickness required for any new material: NEW K of new material (per inch) thickness MAJESTIC SAFETY required = x of listed STRIPS MUST BE thickness K of listed material(per inch) material OVERLAPPED 1/2" MIN.•SEE FIG.& it EXAMPLE FOR COMMON BRICK MINIMUM INSULATION T(new)=5.0/0.458 x 1.00 in.= 10.92 in. (new required VALUE RT=2.18 thickness) (SEE TABLE 4) NOTE:These units are not to be installed in a recessed NOTE: Do not cover grilles on MRC42A and RC36A. combustible floor material so that the extended hearth is flush with the opening.A flush hearth application is acceptable if installed according to Fig. 23. Fig. 23. Protection of adjacent combustible side walls and hearth extension dimensions. H-6. INSTALL DECORATIVE GAS APPLIANCE. The Majestic MR42A/MRC42A Series fireplace is designed to accept a 1/2 inch gas line for an approved gas appliance. Have the appliance installed in accordance with all building codes.The gas connection may enter from either left or right side of the fireplace. 12 Locate the appropriate gas line hole in the outer casing of the Reference Data fireplace and remove the insulation from the gas line tube. AIR SPACE DATA (Refer to Fig. 24.) Any Majestic MR42A/MRC42A Series fireplace can be Next,insert a 1/2 inch gas pipe through the gas line tube from located directly on a flat hard-surfaced combustible floor or the outside of the fireplace and forcibly punch out the ceramic on a wooden platform without air space from combustible knockout on the inside of fireplace. construction. Some protection, however,is required for Now, install the 1/2 inch gas pipe through the opening. After adjacent surfaces as detailed in Fig.25. the gas pipe installation is complete, use the insulation that The minimum air space-to-combustibles requirements for was removed from the gas line tube to repack the space chimney sections and dome are detailed in Fig.25. around the pipe.This should be inserted from the outside of WARNING: DO NOT PACK REQUIRED AIR SPACES the fireplace and packed tightly to totally seal between the WITH INSULATION OR OTHER MATERIALS. pipe and the tube. NOTE:The gas pipe should not come in contact with any wood structures until it has reached a point at least one 1-1/2"AIR SPACE TO COMBUSTIBLE MATERIALS (1)inch away from the fireplace side.(See Fig.24 for COMBUSTIBLE FRAMING installation clarification.) MATERIAL CANNOT NOTE:Local codes may require removal of the flue damper PENETRATE SHADED when installing any type of gas appliance in a fireplace. For AREAS instructions on damper removal, refer to Majestic Instruction BF151. Heat output of a gas appliance installed in the fireplace should be rated less than 100,000 BTU/Hr. The gas pipe installation is intended for connection to a ♦— COM AIR SPACE TO COMBUSTIBLE decorative gas appliance only(1) incorporating an automatic MATERIALS shutoff device and (2)complying with the Standard for Decorative Gas Appliances for Installation in Vented Fireplaces, ANSI Z21.60. The decorative gas appliance should be installed in accordance with the National Fuel Gas Code, ANSI Z223.1 (latest edition). CAUTION:WHEN USING DECORATIVE GAS APPLIANCE, ONLY NON-COMBUSTIBLE THE FLUE DAMPER MUST BE SET IN THE FULLY OPEN FRONT VIEW MATERIAL MAY BE POSITION. APPLIED AS FACING TO THE BLACK HOLE IN FIREPLACE SURROUND OUTER CASING STANDOFF SIDE VIEW CERAMIC KNOCKOUT 3/4" GAS LINE TUBE SUPPLY NOTE:SHADED AREAS INDICATE NECESSARY LINE AIR SPACE TO COMBUSTIBLE MATERIALS CERAMIC REPACK Fig. 25. Minimum air spaces to combustible materials. KNOCKOUT INSULATION HOLE IN (EACH SIDE) OUTER CASING Fig. 24. Install iron pipe gas line through hole provided in either side of fireplace. 13 57-15/16" 7/16" rl i 30-3/16" 3/4" 7/16"— _T_ 40-15/ " 11"DIA. 10-3/4" 8"DIA. 25-1/4" 57-15/16" 81-15/16" 5/8" 41" 41" 34-5/8" 19-1/2" 21-7/16" 38-9/16" 1-1/2" 11-5/8" 8-3/4" . 7 1/4" ��— a2 --� - 47-23/32" --� OUTSIDE AIR i3" GAS LINE COVER ACCESS ACCESS HOLE (MR42A FIREPLACE DOES NOT HAVE GRILLES) ACC ss(MBCA) `16-9/16" Fig. 26. Dimensions of MR42A/MRC42A. 14 51'/6° i 7/16 3/4 n � 26'/32' 11" DIA. / 10 7/1611 23„ r 7?72 e 51'/e 1/a' IA. OUTSIDE AIR COLLAR 342 371/2 3 /16 " 36" I 191/2" 217/16" 11 1/16r' 71/4" 53/4" 11'/2" GAS LINE41 —►� ACCESS HOLE 1411/16' Fig. 27 Dimensions of R36A. 51'/6' 7/16 r 3/4" �261/32,r 11"DIA. 10 23" 36'/1 721/4" 4" DIA.OUTSIDE AIR COLLAR 371/2" I I 36 I 3427/32' ' 3471/16" 32" 191/2" 217/16" I 34'/6" 7'/4' 53/4" GAS LINE ---►� 111/2" ACCESS HOLE 41 1411/16' Fig. 28 Dimensions of RC36A. 15 Accessory Parts The following accessory parts can be obtained from your Majestic Dealer.Should you need additional information beyond what your dealer can furnish, contact the Majestic Company, Huntington, Indiana 46750, Attention: Director of Technical Service. CAUTION:This fireplace and chimney assembly is a highly engineered system and,as such, must be operated only with Majestic products approved components that have been designed as parts of the system.If you use an unapproved component or make any modifications,you may possibly cause afire hazard and will void the Majestic warranty.In addition, such action may void the coverage provided by the owner's home insurance. +' USA Accessories Accessory Description Model Number Glass Enclosure Kit Standard clear-view,bi-fold door set. GBD36 (R36A/RC36A) GBD42(MR42A/MRC42A) Glass Enclosure Kit ImageTM Series glass doors. Upgrade DE36 (R36A/RC36A) style with track and bi-fold glass doors. DE42(MR42A/MRC42A) Glass Enclosure Kit ImageTM Series glass doors. Upgrade DF36 (R36A/RC36A) style with flush fit,full frame,trackless DF42 (MR42A/MRC42A) bi-fold glass doors. Glass Enclosure Kit ImageTM Series glass doors. Upgrade DG36 (R36A/RC36A) style with frame that overlaps fireplace DG42 (MR42A/MRC42A) opening and trackless bi-fold glass doors. Glass Enclosure Kit ImageTM Series glass doors. Upgrade DH36 (R36A/RC36A) style with designer frame that overlaps DH42(MR42A/MRC42A) fireplace opening and trackless bi-fold glass doors. Outside Air Kit Designed to provide outside air for fuel AK-MST combustion in the firebox. This accessory MUST be installed before the fireplace is installed. 6"diameter kit where required by MAK-6 Code. Blower System Designed for use with RC36A fireplace RCFK(RC36A Only) to provide forced air flow. Blower System Designed for use with MRC42A FKSX-A(MRC42A Only) fireplace to provide forced air flow. Blower Speed Control Optional wall mounted variable speed SCVS blower control Replacement Basket Used in firebox to hold firewood. RBG36 (R36A/RC36A Only) Grate RBG42(MR42A/MRC42A Only) Optional Designer Grilles Used to enhance the appearance of OG42BK(Black) your fireplace. OG42PB (Polished Brass) For MRC42A units only Optional Herringbone Designer refractory brick used to OHB42(MR42A/MRC42A Only) Refractory Panel replace the standard brick. 16 Canadian Accessories With Standard SK8 With Optional "S", e Accessory Two-Wall Pipe S"Three-Wall Pipe Chimney Collar Enclosure— This enclosure kit is installed to the outer top of the fireplace and provides outside CCE-SK NONE NEEDED air to assist in cooling the chimney system during fireplace operation. Attic Insulation Shield— Used to prevent attic insulation from AIS-SK FS2100HT contacting the chimney system. Chimney Sections— SK818CAN (1-1/2'Long) 818CAN (1-1/2'Long) Used to build chimney systems exposed SK84CAN (4' Long) 84CAN (4' Long) outdoors above roof. 45° Chimney Elbows— Provides 450 offsets for Canadian SK845/2 NONE NEEDED installation only. (Maximum of 2.) For use ONLY with SK8 chimney. I i 17. tr 18 r i �a t R 1 L l' i� 19 r i r 1 ' t LISTED FOR RESIDENTIAL CONSTRUCTION: R36A/RC36A and MR42A/MRC42 • UNDERWRITERS LABORATORIES REPORT NO. MH6018 Underwriters Laboratories, Inc. i ® C ® L (UNITED STATES) (CANADA) R and MR-Series Fireplaces are covered by Mechanical Patent No.4,519,376 THE W MAJESTIC PRODUCTS COMPANY 1000 East Market St.•Huntington,IN 46750-2579.219.356.8000 74-12-750 RII/1095