Loading...
HomeMy WebLinkAboutMiscellaneous - 657 SALEM STREET 4/30/2018 657 SALEM STREET 210/065.0-0050-0000.0 0 Burgess trightm.an &Y2__ Salem St. APPLICATION FOR SEWAGE DISPOSAL IffiTALIATI HEALTH DEPARTMENT - NORTH ANDOVER, MASS. I hereby make application for a permit for a sewage disposal installation at — __alem St. . I will install this system in ac- cordance with all the laws of the Commonwealth of Massachusetts and regulations of the Board of Health of the Town of North Andover. Further, I will construct the house sewer of bell and spigot pipe, the minimum diameter being 4 inches, and will maintain a minimum grade of 1% until 10 feet pre- ceding the septic tank, where the grade shall not exceed 2%. I will install a con- crete septic tank of 750 Gal. in size. A manhole (s) permitting easy cleaning will be provided with removable cover (s) of iron or concrete within 12 inches of the ground surface. I will provide subsurface disposal field with 4 inch perforated or open jointed pipe and laid in a series of trenches, the bottom of which will pro- vide a minimum of 160 lineal (14bdW feet of effective absorption area. The pipes will be laid on a 6 inch layer of washed gravel or crushed stone ranging in size from 3/4 to 1-1/2 inches (dia. ) and the pipes will be surrounded by similar material to a height of 2 inches above the crown of the pipe. The joints of these pipes will be protected from clogging and before filling the trench, 2 inches of gravel or stone 1/8" to 1/4" (dia. ) will be placed over the course gravel or stone. The disposal field will be installed at a grade of 4 to 6 inches/100 feet. No single tile line will exceed 100 feet in length and in any case, two lines of tile will be installed. A minimum of 6 feet will be maintained between the center lines of the disposal field trenches and the average depth of trench shall not exceed 36 inches. No part of the installation will be less than 100 feet from any private water supply, 25 feet from any stream, 20 feet from any dwelling or 10 feet from any property line. I further agree not to cover any portion of this installation until approved by the inspection officer, as provided below, and to incorporate any additional requirements that may be attached to the permit. Plot Plans must be submitted with application. DA TE /4 Z� Signature of Applicant I hereby issue the above permit for the Board of Health of the Town of North Andover, Massachusetts. DATE / G1066 — J Signature of Health Agent I have inspected ,the uncovered system indicated above and find everything done as describe . DATE Z b Signature o nspecting Officer Percolation Test7 min. Gravel Garbage Grinder i10 October 31, 1959 Miss Mary Sheridan R. N. Health Agent Board of Health North Andover, Mass, Dear Miss Sheridan: : An examination was made as requested in order to determine the suitability of the soil for the subsurface .disposal of sewage on the proposed Salem Street building site of Burgess M. Brightman. The subsoil in the area was of a gravel content and a. 7-minute percolation test was conducted. The land in general is high. It is recommended that a 750 gallon concrete septi: tank be installed together with 160 lineal feet of drain pipe. Very truly yours, William J*D \ll 4 � . gala/ z ,n Trr? BOARD OF HI; .��.i T OWN OF NOR.`H APr O ti'E3� MASS. 7 J tz- d° � f W 7CC) �'�t. Gea na c, �r _ t, u� e ti � - �3►,ter: �o� ,. , _a C/ ell 1 NAME �.,rl��� � .� s DATE ` 2. ADDRESS LOFNO. TEL* . . . . . 3. NO. OF BEDROOIU,S .1% . DEN YES N0, !v`r. . /�. GARBAGE GRINDER YES NO. . 5. SHOW DIh EATS IONS OF HOUSE b. SHOW DISTANCES OF HOUSE TO ALL PROPERTY LINES 7,, SHOW DILENSIOALS OF LOT 8, SHOW LOCATION AND SIZE OF SEPTIC TANK OR CESSPOOL 9, NOTE LOCATION AND DISTANCE OF WELL FROM SEWERAGE SYSTEM 10. SHGW LOCATION OF BROOKS., STREAMS., DITCHES, LEDGE OUTCROP, ETC. 11, SHOW DISTANCE OF SEPTIC TANK OR CESSPOOL FROM HOUSE NOTE: LOCAL REGULAT IOl\JS SHOULD BE, READ CAREFULLY. ����,,,,�,,z.�� 'C�,� ���t,p..e,c,�..� ��trz� C- Eer,��rG[�t Gt,� :iv � � :Zl x y f ..