HomeMy WebLinkAboutMiscellaneous - 67 COLGATE DRIVE 4/30/2018 67 COLGATE DRIVE ` 210/091.0-0010-0000.0 i i 6/28/2016 Date: June 28, 2016 20735 This is an e-permit.To learn more,scan this barcode or visit northandoverma.viewpointcloud.com/#/records/20735 TOWN OF NORTH ANDOVER PERMIT FOR WIRING D This certifies that SUNRUN INSTALLATION SERVICES INC. has permission to perform Installation of an interconnected rooftop PV system-38 panels (9.1 kffl wiring in the buildings of CONRAD, J RICHARD at 67 COLGATE DRIVE , North Andover, Mass. Lic. No. 180120 1/1 d J`�MipsifnOrNiagdovzrma.•newpouRcloudsom:�racwd.12973`Q fi !Z1'Electdcal Cermit"20735-...x Town of North Andover,MA CL ' 20735 i Add;u ap o,ett *Electrical Permit-IN Conjunction with a Building Permit(Commercial or Residential) TIMELINE n C.p— Submission Submission received jun 27,2016 at 1:30p. •. GElectrical Review z o Ca9a1��t. Inpregrrss L! " Applicant locanan Permit pee Nate Ashe 67 COLGATE DRIVE,NORTH ANDOVER, C3 0 payvnem 6 978-793-7227 MA Cb nate.ashe@sunrunhor 0— ,rte Permit Issuance CONRAD,j RICHARD (� Dncm em Attachments up oad F;;e 1,4,`J Res- Primary Contractor rna ge_, htt1lnorth.ndoverma.view oiMcloudcomWrecords/20735 - V ps p Search for contractor using the search bar below.Either the Firm's Name or license 8 is r Monday,Jun 27,2016 01:57 PM 2-o-735' Commonwealth of Massachusetts Official Use Only Department of Fire Services Permit No. Occupancy and Fee Checked BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 CMR 12.00 (PLEASE PRINT ININK OR TYPE ALL INFORMATION) Date: 4/25/16 City or Town of. NORTH ANDOVER To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 67 Colgate Dr Owner or Tenant J Richard Conrad Telephone No. 978-609-2532 Owner's Address 67 Colgate Dr,North Andover MA 01845 Is this permit in conjunction with a building permit? Yes W No ❑ (Check Appropriate Box) Purpose of Building Solar Installation Utility Authorization No. Existing Service Amps / Volts Overhead ❑ Undgrd❑ No.of Meters New Service Amps / Volts Overhead❑ Undgrd ❑ No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of an interconnected rooftop PV system-38 panels(9.1 kw) Completion of the followingtable may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceff.Susp.(Paddle)Fans No.of Total Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ o.o mergency Lighting rnd. rnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS I No.of Zones No.of Switches No.of Gas Burners No.of Detection an Initiating Devices No.of Ranges No.of Air Cond. Total Tons No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained Totals: "" .......... ' '' Detection/Alertin Devices No.of Dishwashers Space/Area Heating KW Local❑ Municipal ❑ Other Connection No.of Dryers Heating Appliances KW Security Systems: No.of Devices or Equivalent No.of Water KW No.of No.of Data Wiring: Heaters Signs Ballasts No.of Devices or Equivalent No.Hydromassage Bathtubs No.of Motors Total HP Telecommunications Wiring.• No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. Estimated Value of Electrical Work: $14732.41 (When required by municipal policy.) Work to Start: Inspections to be requested in accordance with NEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coy age is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE Nr BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Sunrun Installation Services Inc. LIC.NO.: 21136A Licensee: Nathan A Ashe Signature LIC.NO.: 11361 B (If applicable,enter "exempt"in the license number line) Bus.Tel.No.;978-793-7227 Address: 200 Research Dr,Wilmington MA 01887 Alt.Tel.No.: *Per M.G.L c. 147,s.57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's a ent. Owner/Agent PERMIT FEE: $ Signature Telephone No. s f ���IA�SS, HFITSETTS$ — y„1 LICENSE :,Sp 1 r !a t _ as 6S 9aElD 4d NUMBER NONE 596911 4b EXP . Q8 30.2819 3 t class . 12 REST is sFx M t�ttcr 5 6 5 UM _ NONE _ _. _..... ” I. a Iv4MAWA { a 241 RIVER ST EXT 3at993 i BILLERICA,MA 01821 5 DD 0618-2015 Rev 07.152109 / d 11lllllllflillllilllllllllllll(111111111111111111 �� MA I<, www.mass.gaovlrmv MA0616 t t 0630-1903 ' CLASS- + 0: Strep vehicle less than 26,001 Ihs,eXcept school bus. F?1QO[iSHNTS-`� RESTRICTIONS- NOFff' NONE CHANGE OF ADDRESS.PRINT BELOW.PERMANENEINC y►J J i j ::«` ::+COMMONWEALTH OF M � 4HISETT ; ">;` Mom ;6f A ..: `QfF L -tT'RICIANS _ -:: S S U E:.S. THE; }F O L L OW I N G .a"f C E N S E A S< :.:::.: ... R-`E`.`a:>STE WED MAST��2' ;E L E CTR I-C -AN °S€ 00N INSTALLATION SERV I CES INC :: 2 41 R I VER;;:.>ST EXT '<::`'::.'>` ',w_ .'B#-LL ER I G:A >`>'> `'':; A 01821' 344 ':.: 445 4 21136: Q7 R tl I: o s �.� s ACC)R O10/01//20152015® CERTIFICATE OF LIABILITY INSURANCE DATE /YYYY) THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies) must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT MARSH RISK&INSURANCE SERVICES NAME: PHOE FA 345 CALIFORNIA STREET,SUITE 1300 IAICN. No Exit: A/C No): CALIFORNIA LICENSE NO.0437153 E-MAIL SAN FRANCISCO,CA 94104 ADDRESS: INSURER(S)AFFORDING COVERAGE NAIC# 104960339-STND-GAX-15-16 INSURER A:James River Insurance Company 12203 INSURED INSURER B:N/A N/A Sunrun Installation Services,Inc. and REC Solar,Inc. I INSURER C:Houston Casualty Company 42374 775 Fiero Lane,Suite 200 INSURER D San Luis Obispo,CA 93401 INSURER E INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-002994222-03 REVISION NUMBER:5 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP LIMITS LTR POLICY NUMBER MM/DD/YYYY MM/DDIYYYY A X COMMERCIAL GENERAL LIABILITY 000641241 10/0112015 10/01/2016 EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE a OCCUR IMAGE PREMISES TO S(REa ENTED occurrence) ccurrence) $ 300,000 MED EXP(Any one person) $ 10,000 PERSONAL&ADV INJURY $ 1,000,000 GEN-L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 XPOLICY PRO- ❑ JECT LOC PRODUCTS-COMP/OP AGG $ 2,000,000 X OTHER: Host Liquor Liability TOTAL POLICY LIMIT $ 10,000,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Ea accident ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED AUTOS AUTOS BODILY INJURY(Per accident) $ HIRED AUTOS NON-OWNED PROPERTY DAMAGE $ AUTOS Per accident $ C UMBRELLA LIAB X OCCUR H15XC5023203 10/01/2015 10/01/2016 EACH OCCURRENCE $ 10,000,000 X EXCESS LIAB CLAIMS-MADE AGGREGATE $ 10,000,000 DED I I RETENTION$ $ WORKERS COMPENSATIONPER OTH- AND EMPLOYERS'LIABILITY YIN STATUTE I ER ANY PROPRIETOR/PARTNER/EXECUTIVEE.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? ❑ N 1 A (Mandatory in NH) E.L.DISEASE-EA EMPLOYE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT 1$ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space Is required) Re:Permitting within jurisdiction. CERTIFICATE HOLDER CANCELLATION Town of North Andover SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 120 Main Street THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN North Andover,MA 01845 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh Risk&Insurance Services Stefan Szulc �- ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD AC f a CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DDIYYYY) 10/8/2015 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS I CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies) must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: Arthur J. Gallagher&Co. Insurance Brokers of CA. PHONE 415-546-9300 FAx 415-536-8499 1255 Battery Street#450 E-MAIL San Francisco CA 94111 INSURERS AFFORDING COVERAGE NAIC# INSURER A:Zurich American Insurance Company 16535 INSURED SUNRINC-01 INSURER B: Sunrun Installation Services Inc. INSURER C: 775 Fiero Lane, Suite 200 San Luis Obispo, CA 93401 INSURER D INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:944362624 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS 1 CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ` INSR I ADDL SUBR POLICY EFF POLICY EXP I LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER MMIDDIYYYY MMIDDIYYYY LIMITS COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ CLAIMS-MADE OCCUR DAMAGE TO RENTEDPREMISES Ea occurrence $ MED EXP(Any one person) $ PERSONAL&ADV INJURY $ GENT AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ POLICY PRO- JECT LOC PRODUCTS-COMP/OP AGG $ OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ Ea accident ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED AUTOS BODILY INJURY(Per accident) $ HIRED AUTOS NON-OWNED PR PERTY DA AG AUTOS Per accident $ $ UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTION$ $ A WORKERS COMPENSATION PER OTH- A WORKERS COMP NA TION Y WC013696001 10/1/2015 10/1/2016 X STATUTE ER AND y/N WC013696101 0/1/2015 10/1/2016 ANY PROPRIETOR/PARTNER/EXECUTIVE ❑ E.L.EACH ACCIDENT $1,000,000 OFFICER/MEMBER EXCLUDED? N I A (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE1$1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $1,000,000 DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space Is required) WC013696001 -$25,000 Deductible;WC013696101 -FL, HI, MA, NJ, NY, OR,VA,WI only. Evidence of Insurance CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town of North Andover ACCORDANCE WITH THE POLICY PROVISIONS. 120 Main St North Andover MA 01845 USA AUTHORIZED REPRESENTATIVE ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS PAGE# DESCRIPTION • SYSTEM SIZE: 10070W DC, 912OW AC • ALL WORK SHALL COMPLY WITH 2014 NEC, 2009 IBC, MUNICIPAL CODE,AND SE SERVICE ENTRANCE SOLAR MODULES PV-1.0 COVER SHEET • MODULES: (38)CANADIAN SOLAR: CS6P-265P ALL RAIL PV-2.0 SITE PLAN • INVERTER(S): MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. (38) ENPHASE ENERGY: M250-60-2LL-S2X • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2014 NEC. Mp MAIN PANEL 8 e PV-3.0 LAYOUT • RACKING: SNAPNRACK SERIES 100 UL; FLASHED L FOOT. • ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2014 NEC. PV-3.1 STRUCTURAL SEE PEN D01. • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. SP SUB-PANEL PV-4.0 ELECTRICAL • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. STANDOFFS & FOOTINGS PV-5.0 SIGNAGE • INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. LC PV LOAD CENTER • MAIN PANEL REPLACEMENT: EXISTING 100 AMP MAIN . CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(E)AND 2012 CHIMNEY PANEL WITH 100 AMP MAIN BREAKER TO BE REPLACED IFC 605.11.2. -WITH NEW 125 AMP MAIN PANEL WITH 100 AMP MAIN • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. SM SUNRUN METER 0 ATTIC VENT BREAKER. • 9.23 AMPS MODULE SHORT CIRCUIT CURRENT. • 14.42 AMPS DERATED SHORT CIRCUIT CURRENT(690.8 (a) &690.8 (b)). FLUSH ATTIC VENT • STRUCTURAL UPGRADES REQUIRED: CARPORT NEEDS PM DEDICATED PV METER ,��,(N OFiyysSq UPGRADES. SEE SHEET PV-3.0 AND PV-3.1 FOR DETAILS. o PVC PIPE VENT PAUL K. INVERTER(S) WITH ZACHER u'n [INV] INTEGRATED DC ® METAL PIPE VENT o DISCONNECT AND AFCI STRUCTURAL ® T-VENT No. 50100 AC o6/so/2�g � AC DISCONNECT(S) � o�SS/ONAL�G\ SATELLITE DISH DC DC DISCONNECT(S) FIRE SETBACKS D For Structural Only CB COMBINER BOX HARDSCAPE INTERIOR EQUIPMENT —PL— PROPERTY LINE sunrunLE a SHOWN AS DASHED SCALE: NTS A AMPERE AC ALTERNATING CURRENT #180120 AFCI ARC FAULT CIRCUIT INTERRUPTER AZIM AZIMUTH VICINITY MAP COMP COMPOSITION 200 RESEARCH DR,WILMINGTON,MA 01887 DC DIRECT CURRENT PHONE 888.657.6527 (E) EXISTING FAX 805.528.9701 EXT EXTERIOR CUSTOMER RESIDENCE: J FRM FRAMING J RICHARD CONRAD INT INTERIOR en 125 LBW LOAD BEARING WALL 67 COLLATE , 01845 NORTH ANDOVER, MA, 0 MAG MAGNETIC T67 MSP MAIN SERVICE PANEL TEL.(978)609-2532 APN#:091.0-0010 (N) NEW NTS NOT TO SCALE PROJECT NUMBER: Lawrence Colgate Dr OC ON CENTER 222R-067CONR PRE-FAB PRE-FABRICATED f PSF POUNDS PER SQUARE FOOT DESIGNER: PV PHOTOVOLTAIC NICOLE THOMPSON 415.342.3123 TL TRANSFORMERLESS DRAFTER: TYP TYPICAL V VOLTS DIMENSION I W WATTS SHEET REV NAME DATE COMMENTS COVER SHEET REV: A 4/1/2016 133 Andover 11d PAGE PV-1.0 I SITE PLAN-SCALE=3/64"=1'0" PITCH TRUE MAG PV AREA AZIM AZIM (SQFT) ® AR-01 12° 1670 181° 658.7 p� PL v r N OFIyq�9 PAUL K. ZACHER m STRUCTURAL r; No.50100 O O �SS/pNAIL (E) RESIDENCE sunrun (N)ARRAY AR-01 n Q. v #180120 G� 1 4 a 200 RESEARCHDR,WILMINGTON,MA 01887 m PHONE 888.657.6527 FAX 805.528.9701 CUSTOMER RESIDENCE: J RICHARD CONRAD 67 COLGATE DR, NORTH 1 ANDOVER, MA, 01845 TEL.(978)609-2532 APN#:091.0-0010 P� PROJECT NUMBER: PL 222R-067CONR P� DESIGNER: PL NICOLE THOMPSON 415.342.3123 DRAFTER: - - - - - - - - - - - — F/ DIMENSION SE `AC SHEET SITE PLAN REV:A 4%1/2016 _ PAGE PV-2.0 ROOF TYPE ATTACHMENT ROOF HEIGHT ROOF FRAME FRAME TYPE FRAME MAX FRAME OC ROOF EDGE MAX RAIL MAX RAIL DESIGN CRITERIA EXPOSURE MATERIAL SIZE SPAN SPACING ZONE SPAN OVERHANGMODULES: AR-01 COMP SHINGLE FLASHED L FOOT. SEE PEN D01. SINGLE STORY VAULTED WOOD RAFTER 2 X 6 12'-0" 16" N/A 4'-0" 11-8.1 CANADIAN SOLAR: CS6P-265P MODULE DIMS: D1 -AR-01 -SCALE: 3/16"= 1'-0" 64.5"x 38.7"x 1.57" PITCH: 12° MODULE CLAMPS: AZIM: 167° ��(N OFMg9 Portrait: 13.39"- 16.14" PAUL® K. SSG Landscape: 7.87"-9.84" CHER U, MAX DISTRIBUTED LOAD: 3 PSF ZArn -+ SNOW LOAD: 50 PSF 22'-10" ov NSTRUCTURAL 00 co WIND SPEED: 0°65 0/ 100 MPH 3-SEC GUST. - o LAG SCREWS: SSS/ONA�� 5/16"x4.0": 2.5" MIN EMBEDMENT NOTE: - _ INSTALLERS TO VERIFY RAFTER 6- �- SIZE, SPACING AND SLOPED SPANS,AND NOTIFY E.O.R. OF ANY DISCREPANCIES BEFORE 6- -0--4'TYP-4�- PROCEEDING. PENETRATION SPACING: STAGGERED -� D. _ UPGRADES REQUIRED IN CARPORT: 4x6 CROSS BEAM MAXIMUM HORIZONTAL SPAN LENGTH EXCEEDS THE ALLOWABLE MAXIMUM LENGTH OF 6'-6"THUS AN UPGRADE IS REQUIRED. F0— -e -e UPGRADE WITH 4X4 KNEE 6'-6" BRACES . SEE SHEET PV-3.1 9'-9" & PV-3.2 FOR DETAILS. O— — -e -e 32'-5" sunrun -e- #180120 200 RESEARCHOR,WILMINGTON,MA 01887 PHONE 888.657.6527 FAX 805.528.9701 CUSTOMER RESIDENCE: �- 6-- $- J RICHARD CONRAD 67 COLGATE DR, NORTH ANDOVER, MA, 01845 — —O --0 4X6 CROSS BRACE LOCATION SPANNING 8'-6" TEL.(978)609-2532 APN#:091.0-0010 PROJECT NUMBER: [-El- 222R-067CONR 5" DESIGNER: NICOLE THOMPSON 415.342.3123 DRAFTER: DIMENSION - - - -- -- - - - SHEET LAYOUT REV:A 4/4/2016 PAGE PV-3.0 DESIGN CRITERIA MODULES: CANADIAN SOLAR: CS6P-265P IH OFAfq MODULE DIMS: y 64.5"x 38.7"x 1.57" PAUL K. MODULE CLAMPS: ZACHER Portrait: 13.39"- 16.14" 00 STRUCTURAL Landscape: 7.87"-9.84" co No. 50100 MAX DISTRIBUTED LOAD: 3 PSF 061ao1a <c.� SNOW LOAD: 50 PSF 1'_6" o�`SS/ONAL�G\ WIND SPEED: 100 MPH 3-SEC GUST. LAG SCREWS: EXISTING-FRAMING 5/16"x4.0": 2.5" MIN EMBEDMENT NOT SHOWN NOTE: INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND SLOPED SPANS, AND NOTIFY E.O.R. OF ANY DISCREPANCIES BEFORE 'SIMPSON' ACE PROCEEDING. PENETRATION SPACING: POST CAP STAGGERED UPGRADES REQUIRED IN CARPORT: 4x6 CROSS BEAM MAXIMUM EXISTING BEAM HORIZONTAL SPAN LENGTH EXCEEDS THE ALLOWABLE MAXIMUM LENGTH OF 6'-6"THUS AN UPGRADE IS REQUIRED. 5/8"0 LAG SCREW W/ 3" MIN. EMBED UPGRADE WITH 4X4 KNEE 1 INTO BEAM, CENTER ON BEAM, BRACES . SEE SHEET PV-3.1 1 COUNTERSINK AS REQUIRED FOR DETAILS. 4x4 KNEE BRACE sunrun O #180120 5/8"0 LAG SCREW W/ 3" MIN. EMBED 200 RESEARCH DR,WILMINGTON,MA 01887 PHONE 888.657.6527 INTO POST, CENTER ON BEAM (POST), FAX 805.528.9701 COUNTERSINK AS REQUIRED CUSTOMER RESIDENCE: J RICHARD CONRAD EXISTING POST 67 COLGATE DR, NORTH ANDOVER, MA, 01845 TEL.(978)609-2532 APN#:091.0-0010 PROJECT NUMBER: 222R-067CONR DESIGNER: KNEE BRACE DETAIL NICOLE THOMPSON 415.342.3123 SCCtl2: V = l'-O" O DRAFTER: _. DIMENSION SHEET STRUCTURAL REV:A 4/4/2016 PAGE PV-3.1 DESIGN CRITERIA MODULES: CANADIAN SOLAR: CS6P-265P MODULE DIMS: �yjN OFM46��� 64.5"x 38.7"x 1.57" PAUL K. oy MODULE CLAMPS: ZACHER m Portrait: 13.39"- 16.14" -+ Landscape: 7.87"-9.84" STRUCTURAL ��„ No. 50100 MAX DISTRIBUTED LOAD: 3 PSF 06/30/2fd �� SNOW LOAD: 50 PSF �i� WIND SPEED: o�sS�ONAL� 100 MPH 3-SEC GUST. SYMMETRICAL 1'-6" LAG SCREWS: 5/16"x4.0": 2.5" MIN EMBEDMENT ABOUT CENTERLINE EXISTING FRAMING NOTE: INSTALLERS TO VERIFY RAFTER NOT SHOWN SIZE, SPACING AND SLOPED SPANS, AND NOTIFY E.O.R. OF ANY DISCREPANCIES BEFORE PROCEEDING. PENETRATION SPACING: '.SIMPSON' AC STAGGERED POST CAP UPGRADES REQUIRED IN CARPORT: • 4x6 CROSS BEAM MAXIMUM HORIZONTAL SPAN LENGTH ° EXCEEDS THE ALLOWABLE EXISTING BEAM MAXIMUM LENGTH OF 6'-6"THUS AN UPGRADE IS REQUIRED. UPGRADE WITH 4X4 KNEE 5/8"0 LAG SCREW W/ 3" MIN. EMBED BRACES . SEE SHEET PV-3.1 1 INTO BEAM, CENTER ON BEAM, FOR DETAILS. 1� COUNTERSINK AS REQUIRED sunrun 4x4 KNEE BRACE #180120 200 RESEARCHDR,WILMINGTON,MA 01887 PHONE 888.657.6527 FAX 805.528.9701 5/8"0 LAG SCREW W/ 3" MIN. EMBED CUSTOMER RESIDENCE: 5/8"0 LAG SCREW W/ 3" MIN. EMBED INTO POST, CENTER ON BEAM (POST), J RICHARD CONRAD INTO POST, CENTER ON BEAM (POST), COUNTERSINK AS REQUIRED 67 COLGATE DR, NORTH COUNTERSINK AS REQUIRED ANDOVER, MA, 01845 EXISTING POST TEL.(978)609-2532 APN#:091.0-0010 NOTE: PROJECT NUMBER: OFFSET LAG SCREWS INTO POST, 222R-067CONR MIN. OF 1%2", SO AS NOT TO INTERSECT DESIGNER: KNEE BRACE DETAIL "'�°LET"°MPS°" 2 415.342.3123 Scale: 1" = 1�-0" -CD DRAFTER: 2 DIMENSION - — - SHEET -- - - - - - _ STRUCTURAL REV:A 4/4/2016 PAGE PV-3.1 120/240 VAC (N)60A ENPHASE SINGLE PHASE AC COMBINER BOX .MAX 16 MICRO-INVERTERS PER BRANCH CIRCUIT SERVICE [WITH (3) PRE-INSTALLED •MULTIPLE BRANCH CIRCUITS IN PARALLEL 20A PV BREAKERS AND •ENPHASE MULTI-PIN CONNECTORS-- 1 ST AC CONNECTOR AT OMETER#: ENVOY COMMUNICATION EACH BRANCH CIRCUIT IS A SUITABLE DISCONNECTING MEANS. NATIONAL GRID 12853852 GATEWAY] •DO NOT DISCONNECT/CONNECT UNDER LOAD UTILITY CANADIAN SOLAR: CS6P-265P GRID MNEW AN 100A + �ff + 1ff ENPHASE ENERGY: + ff1 MODULES CBREAKER - _� _� M250-60M250 -S2X 1 (END FED) (38) CANADIAN SOLAR: CS6P-265P AND NEW MICRO-INVERTER PAIRS - �� 125A - - _ (1) BRANCH OF MAIN (N) LOCKABLE --- (14) MICRO-INVERTERS PANEL BLADE TYPE (N) SUN RUN (1) BRANCH OF FACILITY AC DISCONNECT METER JUNCTION BOX ✓� s �. LOADS OR EQUIVALENT (14) MICRO-INVERTERS 3 3 3 2 1 (1) BRANCH OF O (10) MICRO-INVERTERS FACILITY 50A PV _ GROUND SQUARE D 250V METER BREAKER AT DU222RB SOCKET 20A BREAKER (A) OPPOSITE END 3R, 60A,2P 125A CONTINUOUS 20A BREAKER (B) OF BUSBAR 120/240VAC & 20A BREAKER (C) 240V METER 200A, FORM 2S CONDUIT SCHEDULE NOTES TO INSTALLER: 1. INSTALL NEW 60 AMP ENPHASE AC COMBINER BOX WITH (3) PRE-INSTALLED # CONDUIT CONDUCTOR NEUTRAL GROUND 20A BREAKERS. sunrun 1 NONE (2) 12 AWG ENGAGE CABLE (1) 12 AWG ENGAGE CABLE (1) 12 AWG ENGAGE CABLE 3. MAIN PANEL REPLACEMENT: EXISTING 100 AMP MAIN PANEL WITH 100 AMP PER BRANCH CIRCUIT PER BRANCH CIRCUIT PER BRANCH CIRCUIT MAIN BREAKER TO BE REPLACED WITH NEW 125AMP MAIN PANEL WITH 100AMP MAIN BREAKER 2 3/4" EMT OR EQUIV. (6) 10 AWG THHN/THWN-2 (3) 10 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 #180120 3 3/4"EMT OR EQUIV. I (2)6 AWG THHN/THWN-2 (1)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 200 RESEARCHDR,WILMINGTON,MA 01887 PHONE 888.657.6527 FAX 805.528.9701 CUSTOMER RESIDENCE: J RICHARD CONRAD MODULE CHARACTERISTICS 67 COLGATE DR, NORTH ANDOVER, MA, 01845 CANADIAN SOLAR: 265 W TEL.(978)609-2532 APN#:091.0-0010 CS6P-265P OPEN CIRCUIT VOLTAGE 37.7 V PROJECT NUMBER: 222 R-067CON R MAX POWER VOLTAGE 30.6 V SHORT CIRCUIT CURRENT 9.23 A DESIGNER: NICOLE THOMPSON 415.342.3123 DRAFTER: DIMENSION - -- --- -- - - - -- - SHEET - - ELECTRICAL REV: A 4/1/2016 PAGE PV-4.0 • • • LABEL LOCATION: POWER • PER CODE:NEC690.13.G.3&NEC V MAIN, • LABEL LOCATION: AWARNING 690.13.G.4 SYSTEM � (AC)(POI) PER CODE:NEC690.13.B THIS EQUIPMENT FED BY MULTIPLE SOURCE PER CODE:705.12(D)(2) TOTAL RATING OF OVER CURRENT • DEVICES,EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED PHOTOVOLTAIC AMPACITY OF BUSBAR EQUIPPEDPER CODE:NEC690.56(C) I WARNING:SHUTDOWN PHOTOVOLTAIC LABEL LOCATION: POWER • (UNDER ROOFING MATERIAL) DO NOT REMOVE UNLESS REPLACED IN EXACT LOCA"nOw"OTOVOLTAIci PER CODE:NEC690.13.G.1 POWER SOURCE DIFIECTLY BELOW AWARNING LABEL LOCATION: - LABEL LOCATION: ELECTRIC SHOCK HAZARD � - • • • (DC)(INV) (DC)(INV) LABEL LOCATION: THE DC CONDUCTORS OF THIS PER CODE:NEC 690.35(F)TO BE USED DISCONNECT PER CODE:NEC690.13.6 SOLAR DISCONNECT: ON POWERONE INVERTER PHOTOVOLTAIC SYSTEM ARE WHEN INVERTER IS UNGROUNDED PER CODE:NEC 690.15 AND NEC 690.13(B) UNGROUNDED AND MAY BE ENERGIZED CAUTION:SOLAR ELECTRIC AC- • LABEL LOCATION: SYSTEM CONNECTED A WARN I N G (AC)(POI) — DISCONNECT PER CODE:NEC690.13.6 LABEL LOCATION: • • • , • , LABEL LOCATION: TURN OFF PHOTOVOLTAIC pER CODEBNEC110.27(C) (AC)(POI) AC DISCONNECT PRIOR TO PER CODE:NEC690.16.13 WORKING INSIDE PANEL PHOTOVOLTAIC AC DIS •NNECT t • • • LABEL LOCATION: MAXIMUM-AC- FLABEL LOCATION: (AC) OPERATING (AC)(POI) • PER CODE:NEC690.33.E.2 PER CODE:NEC690.54 A WA R N I N G OPERATING VOLTAGE ELECTRIC SHOCK HAZARD LABEL LOCATION: LABEL LOCATION: DO NOT TOUCH TERMINALS PER(POI) CAUTION (INDIVIDUAL BREAKERS) TERMINALS ON BOTH LINE AND PER CODE: NEC 690.17.E PHOTOVOLTAIC SYSTEM CIRCUIT IS BACIFED PER CODE:NEC705.12.D.3.4 LOAD SIDES MAY BE ENERGIZED POWER- sunrun RATED MAXIMUM IN THE OPEN POSITION • • DC VOLTAGE IS ALWAYS PRESENT RATED MAXIMUM POWER- • LABEL LOCATION: WHEN SOLAR MODULES ARE #180120 POINT VOLTAGE (DC)(INV) PHOTOVOLTAIC LABEL LOCATION: EXPOSED TO SUNLIGHT MAXIMUM SYSTEM PER CODE:NEC690.53 (DC)(INV) VOLTAGE • PER CODE:IFC.60.11.3 IFC 605.11.1.4 200 RESEARCH D R,WILMINGTON,MA 01887 PHONE 888.657.6527 MAXIMUM CIRCUIT NEC 690.15,NEC 690.13(B)&NEC FAX805.528.9701 690.14C.2. A WARNING INVERTER OUTPUT CONNECTION LABEL LOCATION: CUSTOMER RESIDENCE: DO NOT RELOCATE THIS PER CODE:NEC 705.12.D.2 J RICHARD CONRAD OVERCURRENT DEVICE 67 COLGATE DR, NORTH ANDOVER, MA, 01845 ® ® ® TEL.(978)609-2532 APN#:091.0-0010 LABEL LOCATION: A WARN I N G LEGEND (AC) PER CODE:690.13.6 PROJECT NUMBER: (AC):AC Disconnect222R-067CONR (C):Conduit ELECTRIC SHOCK HAZARD LABEL LOCATION: (CB)Combiner Box DO NOT TOUCH TERMINALS (POI) PER DESIGNER: (D)Distribution Panel TERMINALS ON BOTH LINE AND PER CODE:NEC 690.17.E (DC):DC Disconnect ® ® LOAD SIDES MAY BE ENERGIZED NICOLE THOMPSON 415.342.3123 (IC):Interior Run Conduit IN THE OPEN POSITION (INV):Inverter with integrated DC disconnect DRAFTER: (LC):Load Center DIMENSION I (M):Utility Meter - -(P01):Point of interconnection - _ SHEET - -- - - - - - - SIGNAGE REV:A 4/1/2016 PAGE PV-5.0