Loading...
HomeMy WebLinkAboutMiscellaneous - Berry Street (4)Berry Street Info a 'r° APPLICATION FOR CERTIFICATE OF OCCUPANCY/INSPECTION BUILDING PERMIT #�� S$ACNt)5� ADDRESS/LOCATION OF PROPERTY:_ R rim Map /09 L) Parcel 3 :�, Lot Number_ _ �2_�. � SUBDIVISION: DATE REQUESTED FILED/READY FOR INSPECTION: CLOSING DATE ON PROPERTY:_ tai FIVE (5) DAYS NOTICE PRIOR TO CLOSING DATE IS REOUIRED ALL WORK AND SIGN -OFFS MUST BE COMPLETED WITHIN THIS TIME FRAME. A REINSPECTION FEE OF TWENTY DOLLARS ($20.00) WILL BE CHARGED IF THE STRUCTURE DOES NOT MEET ALL APPLICABLE CODES. APPLICANT SIGNATURE Permit Issued to: [ M, LL) l u r, C. Address: E CONSERVATION PLANNING DPW -WATER METER SEWER CONNECTION ROUTING DPW MUST INDICATE THAT THE WATER METER HAS BEEN INSTALLED PRIOR TO SUBMITTAL OF THE OCCUPANCY/INSPECTION REQUEST DPW SIGNATURE File: Application for OC form revised Jan 2007 Final Construction Control Document To be submitted at completion of construction by a Registered Design Professional for work per the P edition of the Massachusetts State Building Code, 780 CMR, Section 107 Project Title: Berry Farms — Clubhouse Date:4/12/2016 Permit No. 336-2016 Property Address: Berry Street, North Andover, MA Project: Check (x) one or both as applicable: X New construction Existing Construction Project description: Clubhouse I Jeffrey S. Nawrocki MA Registration Number: 34168 Expiration date: 6/30/16 , am a registered design professional, and I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning: Architectural X Structural Mechanical Fire Protection Electrical Other: Describe for the above named project. I, or my designee, have performed the necessary professional services and was present at the construction site on a regular and periodic basis. To the best of my knowledge, information, and belief the work proceeded in accordance with the requirements of 780 CMR and the design documents approved as part of the building permit and that I or my designee: 1. Have reviewed, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Have performed the duties for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Have been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 107. Enter in the space to the right a "wet" or electronic signature and seal: Phone number: 603-433-8639 Ex. 206 Official Name: Permit No.: Version 06 11 2013 Date: r Email: Jeff@jsneng.com Building Official Use Only JEFFREY S. NAWROCKI STRUCTURAL No. 34188 Initial Construction Control Document To be submitted with the building permit application by a Registered Design Professional for work per the 8a` edition of the Massachusetts State Building Code, 780 CMR, Section 107 Project Title: Berry Farms — Club House Property Address: Berry Street, North Andover MA Date:05/20/16 Project: Check (x) one or both as applicable: [XI New construction [] Existing Construction Project description: Construction of a single story Club House for a residential complex. I, Muzaffer Muctehitzade MA Registration Number: 32579 Expiration date: 6/30/2016 , am a registered design professional, and I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning': Architectural Structural Fire Protection X Electrical Mechanical Other: for the above named project and that to the best of my knowledge, information, and belief such plans, computations and specifications meet the applicable provisions of the Massachusetts State Building Code, (780 CMR), and accepted engineering practices for the proposed project. I understand and agree that I (or my designee) shall perform the necessary professional services and be present on the construction site on a regular and periodic basis to: 1. Review, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. Z Perform the duties for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work is being performed in a manner consistent with the approved construction documents and this code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 107. When required by the building official, I shall submit field/progress reports (see item 3.) together with pertinent comments, in a form acceptable to the building official. Upon completion of the work, I shall submit to the building official a `Final Construction Control Document'. Enter in the space to the right a "wet" or electronic signature and seal: Phone number: (617) 338-4406 Building Official Name: Permit No, Email: zadeco@aol.com Date: Building Official Use Only ote 1. Indicate with an `x' project design plans, computations and specifications that you prepared or directly supervised. If 'other' is chosen, provide a description. Version 06 11 2013 Initial Construction Control Document To be submitted with the building permit application by a Registered Design Professional for work per the 8ffi edition of the Massachusetts State Building Code, 780 CMR, Section 107 Project Title: Bevy Farms — Club House Property Address: Berry Street, North Andover MA Date:05/20/16 Project: Check (x) one or both as applicable: [X ] New construction [] Existing Construction Project description: Construction of a single story Club House for a residential complex. I, Mohammed Zade, MA Registration Number: 27233 Expiration date: 6/30/2016 , am a registered design professional, and I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning': Architectural Structural X Mechanical (HVAC) Fire Protection Electrical Other: for the above named project and that to the best of my knowledge, information, and belief such plans, computations and specifications meet the applicable provisions of the Massachusetts State Building Code, (780 CMR), and accepted engineering practices for the proposed project. I understand and agree that I (or my designee) shall perform the necessary professional services and be present on the construction site on a regular and periodic basis to: 1. Review, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Perform the duties for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work is being performed in a manner consistent with the approved construction documents and this code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 107. When required by the building official, I shall submit field/progress reports (see item 3.) together with pertinent comments, in a form acceptable to the building official. Upon completion of the work, I shall submit to the building official a `Final Construction Control Document'. Enter in the space to the right a "wet' or electronic signature and seal: Phone number: (617) 338-4406 Email: zade(a-)zadeeneQineerine.com Building Official Use Only Building Official Name: Permit No.: Date: 1 Note 1. Indicate with an `x' project design plans, computations and specifications that you prepared or directly supervised. If `other' is chosen, `.provide a description. Version 06 11.2013 Initial Construction Control Document To be submitted with the building permit application by a Registered Design Professional for work per the 8"' edition of the Massachusetts State Building Code, 780 CMR, Section 107 Project Title: Berry Farms — Club House Property Address: Berry Street, North Andover MA Date. -05/20/16 Project: Check (x) one or both as applicable: [X ] New construction [] Existing Construction Project description: Construction of a single story Club House for a residential complex. I, Mohammed Zade, MA Registration Number: 27233 Expiration date: 6/30/2016 , am a registered design professional, and I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning': Architectural Structural X Mechanical (PLUMBING) Fire Protection Electrical Other: for the above named project and that to the best of my knowledge, information, and belief such plans, computations and specifications meet the applicable provisions of the Massachusetts State Building Code, (780 CMR), and accepted engineering practices for the proposed project. I understand and agree that I (or my designee) shall perform the necessary professional services and be present on the construction site on a regular and periodic basis to: 1. Review, for conformance to this code and the design concept, shop drawings, samples and other submittals by the 0contractor in accordance with the requirements of the construction documents. 2. Perform the duties for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work is being performed in a manner consistent with the approved construction documents and this code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 107. When required by the building official, I shall submit field/progress reports (see item 3.) together with pertinent comments, in a form acceptable to the building official. Upon completion of the work, I shall submit to the building official a `Final Construction Control Document'. Enter in the space to the right a "wet" or electronic signature and seal: Phone number: (617) 338-4406 Building Official Name: Email: zade(Qa zadeengineering.com Permit No.: Date: Building Official Use Only tum 2 y Note 1. Indicate with an `x' project design plans, computations and specifications that you prepared or directly supervised. If `other' is chosen, provide a description. Version 06 11.2013 I - Initial Construction Control Document To be submitted with the building pennit application by a Registered Design Professional for work per the 8' edition of the Massachusetts State Building Code, 780 CMR, Section 107 Project Title: Berry Farms — Club House Property Address: Berry Street, North Andover MA Date:05/20/16 Project: Check (x) one or both as applicable: [X ] New construction [] Existing Construction Project description: Construction of a single story Club House for a residential complex. I, Muzaffer Muctehitzade MA Registration Number: 32579 Expiration date: 6/30/2016 , am a registered design professional, and I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning': Architectural Structural Fire Protection X Electrical (Fire Alarm) Mechanical Other: for the above named project and that to the best of my knowledge, information, and belief such plans, computations and specifications meet the applicable provisions of the Massachusetts State Building Code, (780 CMR), and accepted engineering practices for the proposed project. I understand and agree that I (or my designee) shall perform the necessary professional services and be present on the construction site on a regular and periodic basis to: 1. Review, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Perform the duties for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work is being performed in a manner consistent with the approved construction documents and this code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 107. When required by the building official, I shall submit field/progress reports (see item 3.) together with pertinent comments, in a form acceptable to the building official. Upon completion of the work, I shall submit to the building official a `Final Construction Control Document'. Enter in the space to the right a "wet" or electronic signature and seal: Phone number: (617) 338-4406 Building Official Name: Permit No.: Email: zadeco@aol.com Date: Building Official Use Only Note 1. Indicate with an `x' project design plans, computations and specifications that you prepared or directly supervised. If `other' is chosen, provide a description. Version 06 11. 2013 L• WATER LINE PRESSURE TEST UNDERGROUND TESTING AND SERVICES, INC. Client: Address Test Date: `t' J/11. Diameter of Main: Time Start: ? 30 Static Pressure: ") C.> Project Name: 04= ,z W y Loc2tion:4_4r:a �" 7 Water System: Length of Main: Time Finished: 3 v Diameter of Main: Length of Main: Test Requirements: (,0 PSI for . / Hrs. Allowable Leakage Loss: > OZ. for / Hrs. Actual Loss: `? OZ. for 1 Hrs. Inspector: Hydrostatic Pressure Test: _ r' 9 s , _ C 1e "7 Failed Approved by: Date: UTS Operator: , , Date: Chlorination Requirements: Gallons of . '='- % Solution. Results and Comments: ^"` 1_,•t ��r,_�'' OFFICE - White Copy CUSTOMER - Yellow Copy ENGINEER - Pink Copy • 809 Back Mountain Road Goffstown, NH 03045 Tel/Fax (603) 497-5549 Cell (603) 759-4088 L• WATER LINE PRESSURE TEST UNDERGROUND TESTING AND SERVICES, INC. Client: Address Test Date: `t' J/11. Diameter of Main: Time Start: ? 30 Static Pressure: ") C.> Project Name: 04= ,z W y Loc2tion:4_4r:a �" 7 Water System: Length of Main: Time Finished: 3 v Diameter of Main: Length of Main: Test Requirements: (,0 PSI for . / Hrs. Allowable Leakage Loss: > OZ. for / Hrs. Actual Loss: `? OZ. for 1 Hrs. Inspector: Hydrostatic Pressure Test: _ r' 9 s , _ C 1e "7 Failed Approved by: Date: UTS Operator: , , Date: Chlorination Requirements: Gallons of . '='- % Solution. Results and Comments: ^"` 1_,•t ��r,_�'' OFFICE - White Copy CUSTOMER - Yellow Copy ENGINEER - Pink Copy • 14, Lab ID No: Haverhill Water Treatment Plant 131 Amesbury Road Haverhill, MA 01830 978-374-2385 Lab ID# MA -M067 399 Frank DeLucia and Son, Inc Rocci DeLucia, Jr Sample: Berry Farms @ Clubhouse No. Andover, MA The Results for the analysis that you requested are as follows: Sample Date: 4/12/2016 Analysis Results MCL TOTAL COLIFORM (per 100 ml) Absent If you have any questions regarding these results please call the laboratory staff at the aforementioned number. ..very truly IVQur Ni L. D'Aoust Plant Chemist Absent Contractor's Material and Test Certificate for Aboveground Piping PROCEDURE Upon Completion of work, inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall be corrected and system left in service before contractor's personnel finally leave the job, ficate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and ractor_ It is understood the owners representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. Property name Berry Farms 7te Property address 1 211 4/2 0 1 6 16 Berry Street, North Andover, MA -Building #4 Accepted by approving authorities (names} North Andover Fire Department Address 124 Main Street, North Andover, MA WA Without Q.C.D. Installation conforms to accepted plans 1J Yes No Water pressure psi Equipment used is approved Yes No Trip point air pressure psi If no, explain deviations Has person in charge of fire equipment been instructed asYes Minutes to location of control valves and care and maintenance No Yes No of this new equipment? If no, explain Instructions Have copies of the following been left on the premises? 1. System components instructions Fx 'I Yes F_� No 2. Care and maintenance instructions xl Yes F7 No 3. NFPA 25 � Yes El ation of s stem Wet System Basement Year of Orifice Temperature Make Model size Quantity rating Tyco TY -B 2015 5.6 147 155°F Sprinklers Globe A-58 2015 5.6 5 155°F Pipe and Type of pipe Per NFPA 13 fittings Type of fittings Per NFPA 13 AlarmR."Mm Room valve or Maximum time to operate Alarm device flow through test connection Type Make Model Minutes Seconds indicator Flow Potter VSR-F Dry valve Q_O.D. Make Model Serial no. Make Model Serial no, pipe ating est WA Without Q.C.D. Time to trip through test connection Minutes Seconds Water pressure psi Air pressure psi Trip point air pressure psi Time water reached test outlet Alarm operated properly Minutes Seconds Yes No With Q.O.D. If no, explain Deluge and preaction valves Pressure reducing valve test Test description Tests Welding Cutouts (discs) Hydraulic data nameplate Remarks Signatures DPneumatic Electric Hydraulics Piping supervised Yes [—]No Detecting media supervised OYes ONo Does valve operate from the manual trip, remote, or both Yes QNo control stations? Is there an accessible facility in each circuit if no, explain 1 for testing? I Dyes ❑No Does each circuit operate Does each circuit operate Maximum time to Make Model supervision loss alarm? valve release? operate release Yes No Yes No Minutes Seconds N/A Location Make and Setting Static pressure. Residual pressure Flow rate and floor Model (flowing) NIA Inlet (psi) Outlet (psi)inlet (psi} Outlet (psi), Flow (gpm) Hydrostatic: Hydrostatic tests shall be made at not less than 200 psi (13.6 bar) for 2 hours or 50 psi (3.4 bar) above static pressure in excess of 150 psi (10.2 bar) for 2 hours, Differential dry -pipe valve.clappers shall be left open during the test to prevent damage" All aboveground piping leakage shall be stopped. Pneumatic: Establish 40 psi (2.7 bar) air pressure and measure drop, which shall not exceed 1, 5 psi (0.1 bar) in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop, which shall not exceed 1.5 psi (0.1 bar) in 24 hrs. All piping hydrostatically tested at 200 psi ( 10.2 bar) for 2 hours If no, state reason Dry piping pneumatically tested x�Yes F__jNo Equipment operates properly EDYes ONO Do you certify as the sprinkler contractor that additives and corrosive chemicals, sodium silicate or derivatives of sodium silicate, brine, or other corrosive chemicals were not used for testing systems or stopping leaks? x�Yes ❑ No Drain lReading o gage located nearwater Residual pressure with valve in test test supply test connection` psi ( bar) connection.open wider Psi( bar) Underground mains and lead-in connections tosystem risers flushed before connection made to sprinkler piping Other Explain Verified by copy of the Contractor's Material and Test Yes �No Certificate for Underground Piping. Flushed by installer of underground sprinkler piping Yes QIN If powder -driven fasteners are used in concrete, Yesx No if no, explain has representative sample testing been N/A satisfactorily completed? Number use ocati Mumber remove Welding piping xjYes DNo If yes.. . Do you certify as the sprinkler contractor that welding procedures complyx�Yes F --- No with the requirementsof at least AWS B2l1? Do you Certify that the welding was performed by welders qualified in x Yes No compliance with the requirements of at least AWS 82/1? Do you :certify that the welding was carried out in compliance with a Yes 1:1 No documented quality control procedure to ensure that all discs are retrieved , that openings in piping are smooth, that slag and other welding residue are removed, and that the internal diameters of piping are not penetrated"? Do you certify that you have a control feature to ensure that x�Yes F_�No all cutouts (discs) are retrieved,? Nameplate provided If no; explain IlYes No Date left in service with all control valves open Name or sprinkler contractor A & E Fire Protection, Inc. Test witnessed by For perty weer (si e 7 Date ''� y t e _ .�. J_2_1 LX bP1111nie1 ovi itional "explanations and notes 'It] Date Contractor's Material and Test Certificate for Aboveground Piping PROCEDURE Upon Completion of work, inspection and tests shall be made by the contractors representative and witnessed by an cwner'.s representative. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. ificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners sand con ractor. It is understood the owner's representative's signature in no way prejudices any claim against contractor for faulty matenal, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. Property name Berry Farms Date 12114/2016: Property address 16 Berry Street, North Andover; MA - Building #4 Accepted by approving authorities (names) North Andover Fire Department Address 124 Main Street, North Andover; MA Installation conforms to accepted plans rx-� Yes ❑ No Equipment used is approved Fx I Yes Q No. If no, explain deviations Has person in charge of fire equipment been instructed as Yes D No to location of control valves and care and maintenance of this new equipment? If no, explain Instructions Have copies of the following been left on the premises? 1. System components instructions fx-� Yes F-1 No 2. Care and maintenance instructions El Yes ❑ No 3. NFPA 25 x❑ Yes ❑ No cationof Wet System IF system Year of Orifice Temperature Make Model size Quantity i rating Tyco LFII 2015 42 166 155"F Sprinklers Tyco TY -FRB 2015 5.6 20 155'F Tyco CC2 1 2015 1 4.2 1 133 200°F Globe A-58 2015 5.6 24 1557 Pipe and Type of pipe Per NFPA 13 Type of fittings Per NFPA 13 fittings Alarm Maximum time to operate valve or Alarm device through test connection flow Type Make Model Minutes Seconds indicator Flow Potter VSR-F Dry valve Q.O.D. Make Model Serial no. Make Model Serial no. Time to trip Time water Alarm through test Water Air Trip point reached operated N/A connection pressure pressure air pressure test outletproperly Minutes Seconds psi psi psi Minutes I Seconds Yes No ry pipe perating test Without Q.O.D. With Q.O.D. If no, explain DPneumatic ElEiectric ❑Hydraulics Piping supervised OYes ElNo Detecting media supervised Yes �No Does valve operate from the manual trip, remote, or both O'luge and control stations? Yes El preaction Is there an accessible facility in each circuit valves for testing? If no, explain E]Yes [�]No Does each circuit operate Does each circuit operate Maximum time o Make Model supervision loss alarm? valve release? operate release N/A Yes No Yes No Minutes Second Pressure Location Make and Setting Static pressure Residual pressure flow rate and floor Model (flowing) reducing N/A valve test Inlet (psi) Outlet (psi) Inlet (psi) Outlet (psi) Flow (gpm) Hydrostatic: Hydrostatic tests shall be made at not less than 200 psi (13.6 bar) for 2 hours or 50 psi (3.4 bar) above static pressur in excess of 15Q psi (10.2 bar) for 2 hours. Differential dry -pipe valve clappers shall be left open during the test to prevent damage. Test All aboveground piping leakage shall be stopped. description Pneumatic: Establish 40 psi (2:7 bar) air pressure and measure drop, which shall not exceed 1.5 psi (0.1 bar) in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop, which shall not exceed 1.5 psi (0.1 bar) in 24 hrs. All piping hydrostatically tested at 200 psi ( 10.2 bar) for 2 hours If no, state reason Dry piping pneumatically tested oYes r_jNo Equipment operates properly oyes ONO Do you certify as the sprinkler contractor that additives and corrosive chemicals, sodium silicate or derivatives of sodium silicate, brine, or other corrosive chemicals were not used for testing systems or stopping leaks? oYes MNo rain ea ing o gage located near water Tests test supply test connection: Resi ual pressure wit valve in test • psi ( bar) connection open wide: psi ( bar) Underground mains and lead-in connections to system risers flushed before connection made to sprinkler piping Other Explain Verified by copy of the Contractor's Material and Test oyes �No Certificate for Underground Piping. Flushed by installer of underground sprinkler piping oyes 0 N If powder -driven fasteners are used in concrete, =Yes x�No has representative sample testing been If no, explain satisfactorily completed? N/A Welding piping Yes Do you certify as the sprinkler contractor that welding procedures comply with the requirements of at least AWS 62/1? Welding Do you certify that the welding was performed by welders qualified in compliance with the requirements of at least AWS B2/1? Do you certify that the welding was carried out in compliance with a documented quality control procedure to ensure that all dl5cs are retrieved , that openings in piping are smooth, that slag and other welding residue are removed, and that the internal diameters of.piping are not penetrated? Cutouts Do you certify that you have a control feature to ensure that (discs) all cutouts (discs) are retrieved'! data nameplate Remarks Date left in service with all c Name of sprinkler contractor A & E Fire Protection, Inc. Signatures For p� perty ow,,�(signed nal explanations and notes valves IT no, explain oyes EDNo Title IX I t'es "No x]Yes ❑No EDYes❑No x�Yes [__j No Date Date ` IL.I-I4 Contractor's Material and Test Certificate for Aboveground Piping PROCEDURE Upon Completion of work, inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall be corrected and system left in service before contractors personnel finally leave the job. Oificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and contractor. It is understood the owners representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. Property name Berry Farms Date 12114/2016 Property address 16 Berry Street, North Andover, MA - Building #4 Accepted by approving authorities (names) North Andover Fire Department Address 124 Main Street, North Andover, MA Installation conforms to accepted plans L^i Yes No Equipment used is approved x� Yes No If no, explain deviations Has person in charge of fire equipment been instructed as L^_I Yes F-� No to location of control valves and care and maintenance of this new equipment? If no, explain Instructions Have copies of the following been left on the premises? 1. System components instructions F-1 Yes F� No 2. Care and maintenance instructions rx-J Yes F� No 3. NFPA 25 x❑ Yes El No cation of system Wet System 2F Year of Orifice Temperature Make Model size Quantity rating Sprinklers Tyco LFII 2015 4.2 166 155°F Tyco TY -FRB 2015 5.6 20 155°F Tyco CC2 2015 4.2 133 200°F Globe A-55 2015 5.6 24 155°F Pipe and Type of pipe Per NFPA 13 fittings Type of fittings Per NFPA 13 Alarm valve or Alarm device Maximum time to operate through test connection flow Type Make Model Minutes Seconds indicator Flow Potter VSR-F Dry valve Q.O.D. Make Model Serial no Make Model Serial no. Time to trip Time water Alarm N/A through test connection Water pressure Air pressure Trip point air pressure reached test outlet operated properly Minutes Seconds psi psi psi Minutes Seconds Yes No pipe erating test Without Q.O.D. With Q.O.D. If no, explain Additional explanations and notes C : Operation ❑Pneumatic F1Electric Hydraulics Piping supervised EYes ENo Detecting media supervised E]Yes ❑No Does valve operate from the manual trip, remote, or both E]Yes L]No Deluge and control stations? preaction Is there an accessible facility in each circuit If no, explain valves for testing? E]Yes FINo Does each circuit operate Does each circuit operate Maximum time to Make Model supervision loss alarm? valve release? operate release Yes No Yes No Minutes Seconds N/A Pressure Location Make and Setting Static pressure Residual pressure Flow rate reducing and floor Model (flowing) valve test NIA Inlet (psi) Outlet,(psi) Inlet (psi) Outlet (psi) Flow (gpm) Hydrostatic: Hydrostatic tests shall be made at not less than 200 psi (13.6 bar) for 2 hours or 50 psi (3.4 bar) above static pressure in excess of 150 psi (10.2 bar) for 2 hours Differential dry -pipe valve clappers shall be left open during the test to prevent damage. Test All aboveground piping leakage shall be stopped_ description Pneumatic Establish 40 psi (2.7 bar) air pressure and measure drop, which shall not exceed 1.5 psi (0.1 bar) in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop, which shall not exceed 1,5 psi (0.1 bar) in 24 hrs. All piping hydrostatically tested at 200 psi { 10.2 bar) for 2 hours If no, state reason Dry piping pneumatically tested F-INo Equipment operates properly E]Yes oNo Do you certify as the sprinkler contractor that additives and corrosive chemicals, sodium silicate or derivatives of sodium silicate, brine, or other corrosive chemicals were not used for testing systems or stopping leaks? X Yes FjNo Drain Reading of gage located near water Residual pressure with -valve in test .Tests test supply test connection: psi( bar) connection open wide: psi( bar) Underground mains and lead-in connections to system risers flushed before connection made to sprinkler piping Other Explain Verified by copy of the Contractor's Material and Test Yes No Certificate for Underground Piping. Flushed by installer of underground sprinkler piping =Yes ONo If powder -driven fasteners are used in concrete, =Yes x 1No If no, explain has representative sample testing been IN/A satisfactorily completed? Blank testing Number used ins Number remove askets Welding piping xlYes [:]No If yes... Do you certify as the sprinkler contractor that welding procedures comply xlYes F_� No with the requirements of at least AWS 62/1? Welding Do you certify that the welding was performed by welders qualified in ]Yes �No compliance with the requirements of at least AWS 132/1? Do you certify that the welding was carried out in compliance with a ElYes No documented quality control procedure to ensure that all discs are retrieved , that openings in piping are smooth, that slag and other welding residue are removed, and that the internal diameters of piping are not penetrated? Cutouts (discs) Do you certify that you have a control feature to ensure that x�Yes �No all cutouts (discs) are retrieved? Hydraulic Nameplate provided If no, explain data DYes F-INo nameplate Remarks -Date left in service with all control valves open Name of sprinkler contractor A & E Fire Protection, Inc. Test witnessed by Signatures For owne (signed) Title Date 7proy Fors rinkler coni ctb 1(si ed) Tnea Dat Additional explanations and notes C : PROCEDURE Contractor's Material and Test Certificate for Aboveground Piping Upon Completion of work, inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall be corrected and system left in service before contractors personnel finally leave the job, ficate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and ractor. It is understood the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances Property name Da Berry Farms 12/1416 Property address 16 Berry Street, North Andover; MA - Building #4 Accepted by approving authorities (names) North Andover Fire Department Address 124 Main Street, North Andover, MA Installation conforms to accepted plans `!X I Yes F_� No f Equipment used is approved Yes No If no, explain deviations Has person in charge of fire equipment been instructed asYes No Fx -1 to location of control valves and care and maintenance of this new equipment? If no, explain Instructions Have copies of the following been left on the premises? 1. System components instructions !_J Yes ❑ No 2. Care and maintenance instructions EXI Yes ❑ No 3. NFPA 25 l Yes L� No tion of s stem Wet System 3F Year of Orifice Temperature Make Model size Quantity rating Tyco LFII 2015 4.2 166 155°F Sprinklers Tyco TY -FRB 2015 5.6 18 155°F Tyco CC2 2015 5.6 133 200`F Globe A-58 2015 5.6 24 155`F Pipe and Type of pipe Per NFPA 13 fittings Type of fittings Per NFPA 13 Alarm Maximum time to operate valve or Alarm device through test connection flow Type Make Model Minutes Seconds indicator Flow Potter VSR-F Dry valve Q.O.D. Make Model Serial no. Make Model Serial no. Time to trip Time water Alarm through test Water Air Trip point reached operated NIA connection pressure pressure air pressure test outlet properly pipe Minutes Seconds psi psi psi Minutes Seconds Yes No Without rating Q.O.D. test With Q.O.D. If no, explain Pneumatic F7Elecfric Hydraulics Piping supervised oYes DNo Detecting media supervised ❑Yes FjNo Does valve operate from the manual trip, remote, or both eluge and control stations? 17Yes QNo preaction Is there an accessible facility in each circuit valves for testing? If no, explain F]Yes ❑ No Does each circuit operate Does each circuit operate Maximum time to Make Model supervision loss alarm? valve release? operate release Yes No Yes No Minutes Seconds N/A Pressure and fltoor Make and Setting Static pressure Residual pressure Flow rate reducing Model (flowing) valve test NSA Inlet (psi) Outlet (psi) Inlet (psi) Outlet (psi) Flow (gpm) Hydrostatic: Hydrostatic tests shall be made at not less fnan 200 psi (13.6 bar) far 2 hours or 50 psi (3,4 bar) above static pressure in excess of 150 psi (10.2 bar) for 2 hours. Differential dry -pipe valve clappers shall be left open during the test to prevent damage. Test All aboveground piping leakage shall be stopped. description Pneumatic. Establish 40 psi (2.7 bar) air pressure and measure drop, which shall not exceed 1.5 psi (0.1 bar) in 24 hours. Test Pressure tanks at normal water level and air pressure and measure air pressure drop, which shall not exceed 1.5 psi (0.1 bar) in 24 hr's. All piping hydrostatically tested at 200 psi( 10-2 bar) for 2 hours If no, state reason Dry piping pneumatically Tested x�Yes �No Equipment operates properly x�Yes EDNo Do you certify as the sprinkler contractor that additives and corrosive chemicals, sodium silicate or derivatives of sodium silicate, brine, or other corrosive chemicals were not used for testing systems or stopping leaks? F-1Yes F-1No rain Reading o gagelocated near water Residua pressure with valve in test Tests test supply test connection: psi ( bar) I connection open wide: Psi( ( bar) Underground mains and lead-in connections to system risers flushed before connection made to sprinkler piping Other Explain Verified by copy of the Contractor`s Material and TestYes []No for Underground Piping, Flushed by installer of underground sprinkler piping x�Yes No If powder -driven fasteners are used in concrete, =Yesx�No `If no, explain has representative sample testing been satisfactorily completed? N/A Blank testing urn er use Welding piping xnYes (IN. Name of sprinkler contractor & E Fire.Protection, Inc. Signatures Fo pe owner i ned) Title � �Y Title Date or sprinkler contradt r ig d T 7' �, A Datrs �) c S u � ---(10 litional explanations and notes 1 Do you certify as the sprinkler contractor that welding procedures comply with the requirements of at least AWS 62/1? ElYes rlNo Welding Do you certify that the welding was performed by welders qualified in compliance with the requirements of at least AWS 132/1? xx �No Do you certify that the welding was carried out in compliance with a documented quality control procedure to ensure that all discs :]YeS No are retrieved , that openings openings in piping are smooth, that slag and other welding residue are removed, and that the internal diameters of piping are not penetrated? Cutouts (discs) Do you certify that you have a control feature to ensure that an cutouts (discs) are retrieved" Yes �No Hydraulic data Nameplate provided If no, explain lamepJate x�Yes �No Remarks Date left in service with all control valves open Name of sprinkler contractor & E Fire.Protection, Inc. Signatures Fo pe owner i ned) Title � �Y Title Date or sprinkler contradt r ig d T 7' �, A Datrs �) c S u � ---(10 litional explanations and notes 1 Contractor's Material and Test Certificate for Aboveground Piping Dry valve Q O.D PROCEDURE Model Serial no. Make Model Upon Completion of work, inspection and tests shall be made by the contractor's representative and witnessed by an owners representative. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. *ificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and Pc rating es t �'actor, It is understood the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor Time to trip through test connection Minutes Seconds workmanship, or failure to comply with approving authority's requirements or local ordinances. Air pressure psi Property name Berry Farms Date Property address 12/1416 Alarm operated properly 16 Berry Street, North Andover, MA - Building #4 Seconds Accepted by approving authorities (names) Nc North Andover Fire Department With Q.O.D. Address 124 Main Street, North Andover. MA Installation conforms to accepted plansYes ❑ No Equipment used is approved Fx Yes If � No no, explain deviations If no, explain Has person in charge of fire equipment been instructed as Yes Ex I No to location of control valves and care and maintenance of this new -equipment? If no, explain Instructions Have copies of the following been left on the premises? 1. System components instructions x� YeATemperature 2. Care and maintenance instructions x1 Ye3. NFPA 25 Yetion of s stem Wet System 4F Yearof Orifice Make Model size Quantity rating Sprinklers Tyco LFII 2015 4.2 185 155°F Tyco TY -FRB ! 2015 5.6 11 155°F Globe A-58 2015 5.6 11 155°F Pipe and Type of pipe Per NFPA 13 fittings Type of fittings Per NFPA 13 Alarm Maximum time to operate valve or Alarm device flow Type Make through test.connection indicator Minutes Seconds Flow Potter Model VSR-F Dry valve Q O.D Make Model Serial no. Make Model Serial no. Pc rating es t NSA Without Q.O.D. Time to trip through test connection Minutes Seconds Water pressure psi Air pressure psi Trip point airressure p psi Time water reached test outlet Alarm operated properly Minutes Seconds Yes Nc With Q.O.D. If no, explain 'Additional explanations and notes ' 'X tv ,t Operation ❑Pneumatic Electric Hydraulics 40eluge Piping supervised [::]Yes DN0-1Detecting media supervised oYes oNo Does valve operate from the manual trip, remote, or both and control stations? oyes No preaction Is there an accessible facility in each circuit If no, explain. valves for testing? oyes oNo Make Model Does each circuit operate Does each circuit operate Maximum time to supervision loss alarm? valve release? operate release N/A Yes Yes No Minutes seconds Pressure Location Make and Settingressure Residual pressure Flow rate and floor Madel t1nIet(psi) reducing (flowing) N/A valve test Outlet (psi)Inlet (psi) Outlet (psi) Flow (gprn) Hydrostatic: Hydrostatic tests shall be made at not less than 200 psi (13.5 bar)for 2 hours or 50 psi (3.4 bar) above static pressure Test in excess of 150 psi (10.2 bar) for 2 hours. Differential dry -pipe valve clappers shall be left open during the test to prevent damage. All aboveground piping leakage shall be stopped. description Pneumatic: Establish 40 psi (2,7 bar) air pressure and measure drop, which shall not exceed 1,5 psi (0.1 bar) in 24 hours. Test Pressure tanks at normal water level and air pressure and measure air pressure drop, which shall not exceed 1.5 psi (0.1 bar) in 24 hrs. All piping hydrostatically tested at 200 psi( 10.2 bar) for 2 hours If no, state reason Dry piping pneumatically tested xoYes ONo Equipment operates properly x�Yes =No Do you certify as the sprinkler contractor that additives and corrosive chemicals, sodium silicate or derivatives of sodium. silicate, brine, or other corrosive chemicals were not used for testing systems or stopping leaks? FjYes oNo Drain Reading o gage locate near water Residua pressure with valve in test test supplytest connection: bar) •Tests Psi( connection open wide: psi( bar) Underground mains and lead-in connections to system risers flushed before connection made to sprinkler piping Other Explain Verified by copy of the Contractor's Material and Test [X yes Certificate for Underground Piping. Flushed by installer of underground sprinkler piping =Yes ONo If powder -driven fasteners are used in concrete, oYesNo If no, explain 17X has representative sample testing been satisfactorily completed? N/A Blank testing um er use ovations askets Number remove Welding piping x]Yes oNo If yes... Do you certify as the sprinkler contractor that welding procedures comply xx Yes oNo with the requirements of at least AWS 8211? Welding Do you certify that the welding was performed by welders qualified in Dyes compliance with the requirements of at least AWS 82/1? oNo Do you certify that the welding was carried cut incompliance with a xoYes o No documented control quality procedure to ensure that all discs are retrieved , that openings in piping are smooth, that slag and other welding residue are removed, and that the internal diameters of piping are not penetrated? Cutouts (discs) Do you certify that you have a control feature to ensure that all cutouts (discs) are retneved'i xoYes oNo Hydraulic Nameplate provided If no, explain data 1X___1 Yes oNo nameplate Remarks Date left in service with all control valves open Name of sprinkler contractor A & E Fire Protection, Inc. Signatures Test witnessed by For prggiI y owner (signed . Title., Date cr/ Fo sprinkler contr orqNe Ti le (� p 1tc3-litiG Date i ,r.. 'Additional explanations and notes ' 'X tv ,t PROCEDURE Contractor's Material and Test Certificate for Aboveground Piping Upon Completion of work, inspection and tests shall be made by the contractors representative and witnessed by an owner's representative. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. rficate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and actor. It is understood the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. Property name Berry Farms Date 8/30/2016 Property address 16 Berry Street, North Andover, MA - Building #4 Accepted by approving authorities (names) North Andover Fire Department Address 124 Main Street, North Andover, MA Installation conforms to accepted plans o Yes ® No Equipment used is approved xl Yes No If no, explain deviations Has person in charge of fire equipment been instructed asYes FX No to location of control valves and care and maintenance of this new equipment? If no, explain Instructions Have copies of the following been left on the premises? 1. System components instructions 0 Yes No 2. Care and maintenance instructions 0 Yes No 3. NFPA 25 - x❑ Yes No tion of s stem Dry System Attic Year of Orifice Temperature Make Model size Quantity rating Tyco TY -FRB 2015 5.6 34 2002F Sprinklers Tyco B132 2015 8 31 200°F Tyco B132 2015 5.6 1 56 200°F Tyco TY -FRB 2015 5.6 28 200°F Pipe and Type of pipe Per NFPA 13 fittings Type of fittings Per NFPA 13 Alarm Maximum time to operate valve or Alarm device through test connection flow Type Make Model Minutes Seconds indicator Flow Potter PS10 Dry valve Q.O.D. Make Model. no. Make Model Serial no. Tyco DPV-1 Time to trip Time water Alarm through test Water Air Trip point reached operated N/A connection pressure pressure air pressure test outlet properly pipe Minutes Seconds psi psi psi Minutes Seconds Yes No Without �ry erating Q.O.D. test With Q_O.D. If no, explain ❑Pneumatic Electric QHydraulics Piping supervised EYes ONO Detecting media supervised ❑Yes DNo Does valve operate from the manual trip, remote, or both luge and 14 control stations? Yes oNo preaction Is there an accessible facility in each circuit valves for testing? Ifno, explain QYes ONo oes each circuit operate Does" each circuito perate Maximum time to Make Model supervision loss alarm? valve release? Yes No operate release N/A Yes No Minutes Seconds Location Make and Setting Pressure and floor rate Static pressure Residual pressure Flow reducing Model (flowing) valve test N/A Inlet (psi) Outlet (psi) Inlet (psi) Outlet (psi) Flow (gpm) Hydrostatic: Hydrostatic tests shall be made at not less than 200 psi (13.6 bar) for 2 hours or 50 psi (3.4 bar) above static pressure Test n excess of 150 psi (10.2 bar) for 2 hours. Differential dry -pipe valve clappers shall be left open during the test to prevent damage. description All aboveground piping leakage shall be stopped. Pneumatic: Establish 40 psi (2.7 bar) air pressure and measure drop, which shall not exceed 1.5 psi (0.1 bar) in 24 hours. test pressure tanks at normal water level and air pressure and measure air pressure drop, which shall not exceed 1.5 psi (0.1 bar) in 24 hrs. All piping hydrostatically tested at 200 psi ( 10.2 bar) for 2 hours If no, state reason Dry piping pneumatically tested aYes oNo Equipment operates properly x�` Yes No Do you Certify as the sprinkler contractor that additives and corrosive .chemicals, sodium silicate or derivatives of sodium silicate, brine, or other corrosive chemicals were not used for testing systems or stopping leaks? x�Yes F -]No .1—� y ui yage located near water _Tests test supply test connection 7=,s=n test psi ( bar) psi ( bar) Underground mains and lead-in connections to system risers 'feorecoion made to sprinkler piping Verified by copy of the Contractor's Material and Test Other Explain Certificate for Underground Piping. oyes DNo Flushed by installer of underground sprinkler piping QYes =No If powder -driven fasteners are used in concrete, has representative sample test ing been =Yes LI No If no, explain satisfactorily completed? N/A 3lank testing um er use nnnf—, Welding piping FYes F Remarks Date left in service with all control valves open • Name of sprinkler contractor A & E Fire Protection, Inc. Test witnessed by Signatures For!erty owner (si ne TitleateFor sler, contr t s ned rV O� T , 1J_l J"Date 1, ,dditional explanans t and notes tio�y��� ���. Do you certify as the sprinkler contractor that welding procedures comply with the requirements of at least AWS 92/19 xx Yes oNo Welding Do you certify that the welding was performed by welders qualified in compliance with the requirements xx of at least AWS B2/1? �No Do. you certify that the welding was carried out in compliance with a documented quality control procedure to ensure that all discs are retrieved ayes oNo , that openings in piping are smooth, that slag and other welding residue are removed, and that the internal diameters of piping are not penetrated'? Cutouts (discs) Do you certify that you have a control feature to ensure that ail cutouts (discs) are retrieved'? xoYes ONO Hydraulic data Nameplate provided If no, explain nameplate x�Yes ONO Remarks Date left in service with all control valves open • Name of sprinkler contractor A & E Fire Protection, Inc. Test witnessed by Signatures For!erty owner (si ne TitleateFor sler, contr t s ned rV O� T , 1J_l J"Date 1, ,dditional explanans t and notes tio�y��� ���. 0 December 14, 2016 Fire Prevention North Andover Fire Department 124 Main Street North Andover, MA. 01845 Re: Berry Farms - Building 4 16 Berry Street North Andover, MA 01845 Fire Sprinkler Final. Contractor's Affidavit The fire sprinkler system at the above referenced project was designed and installed per A&E Fire Protection's drawing FP8-FP9 dated 10/2/2015 and meets the requirements of NFPA 13, 2013, and the 8tr. Edition of the Massachusetts State Building Code. µOFfyys, . sy0 NATHANIEL Sincerely,PHILLF a O FIRE. PROTECTION 07 No. 39850 R �G/STER���a Nathaniel R. Phillips Registered Professional Fire Sprinkler Engineer :7 0 III C0NSP1TAkE-CT1 • 0 M ■ TRANSMITTAL COPIES , DATE N0, DESCRIPTION. 8/8/2016 'Bldg #1 Bldg Permit Card Bldg #1 Affidavits Bldg #1 C of O - 3 floors Bldg #1 Warranty Berry Farms, N. Andover, MA O: FROM: David M White Gerald Fransen COMPANY: DATE: David M White Architect August 8; 2016 WE ARE SENDING YOU: Shop Dwgs ©Prints Samples E Plans —]Spec's X ]Other HESE ARE TRANSMITTED FOR: Approval X❑use Review [:]Appv'd F-]Appv'd W/NoteQResubmit NUMBER. OUR SUBMITTAL NUMBER 200 COPIES , DATE N0, DESCRIPTION. 8/8/2016 'Bldg #1 Bldg Permit Card Bldg #1 Affidavits Bldg #1 C of O - 3 floors Bldg #1 Warranty `at I.: Wo • J O V z , Q� a z W a O z _� (.i W m C w r � m tj �.. W WZO 17 {L LL u LL VI LL K U LL -CC W LC l/1 IL tin O' LL m N M I.: Wo • a w CD �. Z O = cl -- IkK- �, Aq O •E t v m m z i O O co® _ s �� w .� :2 O �,d -goo UJ 0 y C _ 0co t ui G .v J t C Z O Q N A � a w �ac IF*q I— 0771f4 lie Project Title: Property Address: Final Construction Control Document To be submitted at completion of construction by a Registered Design Professional for work per the 8's edition of the Massachusetts State Building Code, 780 CMR, Section 107 -- M11fV_ Date: � Permit NO.�!JI Project: Check one or both as applicable: J%New construction U Existing Construction I yal,V QJ M. WW -6 MA Registration Number: _ Expiration date: am; a registered design professional, and I have prepared or directly supervised time preparation of all design plans, computations and specifications concerning: • N Architectural i [ ] Fire Protection [ ] Structural [ ] Mechanical [ } Electrical [ } Other: for the above named project. 1, or my designee, have performed the necessary professional services and was present at the construction site on a regular and periodic basis. To the best of my knowledge, information, and belief the work proceeded in accordance with the requirement of 780 CMR and the design documents approved as part of the building permit and that I or my designee: 1. Have reviewed, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Have performed the duties for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Have been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this code. Nothing in this document relieves the contractor of ibilty regarding the provisions of 780 CMR 107, ED Aoio? Q� X10 ►�• RYy C Enter in the space to the right a "wet" or electronic signature and seal: /xtiipJr�aE Phone number: A1OF*p Building Official Use Only Building Official Name: Permit No.. Date: Version 06 11 2013 Final Construction Control Document To be submitted at completion of construction by a Registered Design Professional for work per the 8t' edition of the Massachusetts State Building Code, 780 CMR, Section 107 Project Title: Berry Farms — Building 1 Date:5/10/2016 Permit No. 331-2016 Property Address: Berry Street, North Andover, MA Project: Check (x) one or both as applicable: X New construction Existing Construction Project description: Apartment Building I Jeffrey S. Nawrocki MA Registration Number: 34168 Expiration date: 6/30/16 , am a registered design professional, and I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning: Architectural X Structural Mechanical Fire Protection Electrical Other: Describe for the above named project. I, or my designee, have performed the necessary professional services and was present at the Onestruction site on a regular and periodic basis. To the best of my knowledge, information, and belief the work 0s ded in accordance with the requirements of 780 CMR and the design documents approved as part of the building permit and that I or my designee: 1. Have reviewed, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Have performed the duties for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Have been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 107. Enter in the space to the right a "wet" or electronic signature and seal: *,--- 4n2 All Q420'C- WIA JEFFREY S. NAWROCKI STRUCTURAL No. 34188 �d�OM1L Flm�ilTPffinlicnPna rnrn t111V�1V Jl W.1JUVl. VV✓ -T✓✓ -uv✓✓ .un. c.vv i+++w.+. Building Official Use Only Building Official Name: Permit No:: Date: Version 06 11 2013 ` Initial Construction Control Document To be submitted with the building permit application by a a Registered Design Professional for work per the 8t' edition of the Massachusetts State Building Code, 780 CMR, Section 107 Project Title: Berry Farms — Building 1 Property Address: Berry Street, North Andover MA Date:05/20/16 Project: Check (x) one or both as applicable: [X ] New construction [] Existing Construction Project description: Construction of a 3 story residential building. I, Mohammed Zade, MA Registration Number: 27233 Expiration date: 6/30/2016 , am a registered design professional, and I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning': Architectural Structural X Mechanical (PLUMBING) Fire Protection Electrical Other: for the above named project and that to the best of my knowledge, information, and belief such plans, computations and specifications meet the applicable provisions of the Massachusetts State Building Code, (780 CMR), and accepted � gineenng practices for the proposed project. I understand and agree that I (or my designee) shall perform the necessary ofessional services and be present on the construction site on a regular and periodic basis to: y l . Review, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Perform the duties for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Be present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work is being performed in a manner consistent with the approved construction documents and this code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 107. When required by the building official, I shall submit field/progress reports (see item 3.) together with pertinent comments, in a form acceptable to the building official. Upon completion of the work, I shall submit to the building official a `Final Construction Control Document'. Enter in the space to the right a "wet" or electronic signature and seal: Phone number: (617) 338-4406 Email: zade@zadeengineering.com Building Official Use Only Building Official Name: Permit No.: Date: Note 1. Indicate with an `x' project design plans, computations and specifications that you prepared or directly supervised. If `other' is chosen, provide a description. Version 06 11 2013 Initial Construction Control Document To be submitted with the building permit application by a 1 Registered Design Professional for work per the 8'h edition of the Massachusetts State Building Code, 780 CMR, Section 107 Project Title: Berry Farms — Building 1 Date:05/20/16 Property Address: Berry Street, North Andover MA Project: Check (x) one or both as applicable: [X ] New construction [] Existing Construction Project description: Construction of a 3 story residential building. I; Muzaffer Muctehitzade MA Registration Number: 32579 Expiration date: 6/30/2016 , am a registered design pro, fessiona4 and I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning': Architectural Structural Fire Protection X Electrical (Fire Alarm) Mechanical Other: for the above named project and that to the best ofmy knowledge, information, and belief such plans, computations and specifications meet the applicable provisions ofthe Massachusetts Stater Building Code, (780 CMR), and accepted engineering practices for the proposed project. I understand and agree that I (or my designee) shall perform the necessary 06tessional services and be present on the construction site'ort a regular and periodic basis to: 1. Review, for eonfornmee to this code and thedesign concept, shop drawings, samples and other submittals by the contractor in accordance with therequirements of the construction documents. 2. Perform the duties for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Be present at intervals appropriate to the stage of construction to become generally &Milian with the progress and quality of the work and to determine if the work is being performed in a, manner consistent_ with the approved construction documents and this code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 107. When required by the building official, I shall submit field/progress reports (see item 3.) together with pertinent comments, in a form acceptable to the building official. Upon completion of the work, I shall submit to the building official a `Final Construction Control Document'. Enter in the space to the right a "wet" or electronic signature and seal: Phone number: (617) 338-4406 Email: zadeco@aol.com Building Official Use Only riding Official Name: Permit No.: Date: i .�.0 "UU1LdWwain an x prosect aesign plans, computations and specifications that you prepared or directly supervised. If `other' is chosen, provide a description. July 22, 2016 Fire Prevention North Andover Fire Department 124 Main Street North Andover, MA. 01845 Re: Berry Farms - Building #1 10 Berry Street North Andover, MA 01845 Fire Sprinkler Final Contractor's Affidavit d The fire sprinkler system at the above referenced project was designed and installed per A&E Fire Protection's drawing FP2-FP3 dated 10/2/2015 and meets the requirements of NFPA 13, 2013, and the 8�' Edition of the Massachusetts State Building Code. A'9t MA' .�N OF I6lA Sincerely, ° NATHANIE1 PHILLIPS FIRE PR07 EG7ION tri NO. 3985D Nathaniel R. Phillips Registered Professional Fire Sprinkler Engineer • r Zade Associates, INC. Consulting Engineers 140 Beach St., Boston, MA 02111 Phone: (617) 338-4406 Fax: (617) 451-2540 Email: zade0zadeengineerinq com David White 54 Todd Street P.O. BOX 817 New London NH 03257 Attn: David Ref: Berry Farms, North Andover Mohammed Zade Ph.D., P.E. Muzaffer Muctehitzade M.Sc., P.E. July 28, 2016 We have checked the drawings. 1" drain pipe from drain pan to 1-112" riser Is sufficient for the relief valve discharge. If you need any further information, Please call us. Sincerely, Mohammed Zade Ph.D, RE Zade Associates LLC • 0 CERTIFICATE OF USE & OCCUPANCY TOWN OF NORTH ANDOVER Valid for Until September 6, 2016 Building Permit Number 331-2016 on 9/15/2015 Date: August 4, 2016 THIS CERTIFIES THAT THE BUILDING LOCATED ON 10 Berry Street — Building One- First Floor MAY BE OCCUPIED AS Building One — First Floor IN ACCORDANCE WITH THE PROVISIONS OF THE MASSACHUSETTS STATE BUILDING CODE AND SUCH OTHER REGULATIONS AS MAY APPLY. Certificate Issued to: North Andover Holdings, LLC Fee: $100.00 Receipt: 30704 Check: 226 16 Berry Street North Andover, MA 01845 o • r: CERTIFICATE OF USE & OCCUPANCY TOWN OF NORTH ANDOVER Valid for Until September 6, 2016 Building Permit Number 331-2016 on 9/15/2015 Date: August 4, 2016 THIS CERTIFIES THAT THE BUILDING LOCATED ON 10 Berry Street — Building One- Second Floor MAY BE OCCUPIED AS Building One — Second Floor IN ACCORDANCE WITH THE PROVISIONS OF THE MASSACHUSETTS STATE BUILDING CODE AND SUCH OTHER REGULATIONS AS MAY APPLY. Certificate Issued to: North Andover Holdings, LLC Fee: $100.00 Receipt: 30704 Check: 226 16 Berry Street North Andover, MA 01845 •g Inspector µowT1t TEMPORARY CERTIFICATE OF USE & OCCUPANCY TOWN OF NORTH ANDOVER Valid for Until September 6, 2016 Building Permit Number 331-2016 on 9/15/2015 Date: August 4, 2016 THIS CERTIFIES THAT THE BUILDING LOCATED ON 10 Berry Street— Building One- Third Floor MAY BE OCCUPIED AS Building One — Third Floor IN ACCORDANCE WITH THE PROVISIONS OF THE MASSACHUSETTS STATE BUILDING CODE AND SUCH OTHER REGULATIONS AS MAY APPLY. Certificate Issued to: North Andover Holdings, LLC • 16 Berry Street North Andover, MA 01845 Fee: $100.00 Receipt: 30704 Check: 226 0 r d 51' 11 Building Inspector • 0 PILOT CONSTRUCTION, INC. WARRANTY & PROCEDURE for Berry Farms - North Andover, Ma In accordance with the Contract Documents Pilot Construction, Inc., shall warranty all work for Building 10 (Berry Street) of the project known as Berry Farms for a period of one year starting on July 29, 2016, and ending on July 28, 2017. It is our preference that all warranty claims initiated by the Owner follow the following procedures after an evaluation by your on-site Maintenance: ,. Utilizing the Subcontractor Contact List attached, notify the trade determined to be responsible, in writing preferably. z If no response is received from the responsible trade within three working days, notify Pilot Construction, Inc. at their Portsmouth, New Hampshire office in writing at fax: (603-436-3946). 3 If there is any confusion regarding which trade may be responsible for a warranty item, notify Pilot Construction, Inc. for direction. If at any time there is a need of assistance with the execution of the repair of a warranty item, please do not hesitate to contact Pilot Construction, Inc., to facilitate the process. PILOT CONSTRUCTION, INC. Ger Id Fransen, Project Manager 7 - Date r -I L 0 I* E 0 � � _ r . .. .. � �.... . E . k § 2 $ ] 10■ m & \ 7 C,4 4 2 m 2 2 2 C-3& 2 2 ' ■ to S C"! O j ■ k t m ■ k ( ƒ ca k o i) � W Q Z 0 Q W LU 2 a / \ 6 W 2 7 ® o % a CIL k % / — k / \ £ I t E � k k m k . o... ..� ... . 9 . .......... . . .«- = .- m ... o \ k \ M § kk \ kco - k k \ k � ■ § k E R k % 2 � 5 k 2§ f 2 W Q � § U . � Q � 2 a k - & 00 k d Cl) ® 7\ k k G {# I /&\ 2 \ / f \ 0 2 � \ 2 = E c £ k § { & / o § R£ c t q @ 2 2 \ m@ $§$ m ■ m 3 « o% t� :01 I J 2 2 w 2 2 3 2�@ 2 CL § U) ® W _ t vi coal / mf.2 ....... .... .. . . . 11 0 , � < .. . « n n . . Q j \ § § \ 40 A 4 w* k ' k © & q R R & 0 1to k kP�- rl§ t i A $ § t -214. 2 W Q � § U W k � 2 (3 \ \ ] � / G 3 f Q) w I \ \ z \ \ / ° S ¢ o A / / \ , ƒ E � t c ) j 2 2 g i m » k /\Lo /§\ 2§ J k X § . 14 F 2 . . a...� .. . . ... • 0 a� c zs c Cl) N N M F OL6i O to N N M co t 14 d Cf d b ti ff d Zi O F r �p O Y — C LL h Co V p p J � cko a� �a � w ti 0 U F. w 0 a e ,o _ V O D O Orm U ? O O h c u o N C m o ,Q° ,ro a b aj o E C_ C m z 4 m Uzz, E. U) aLILI z �Q 0 • CJ 0 O N O O Ntf � cli O M QD M 0p i � M rO � � N � M M N n 00 U LO 00 N ` 12-1 r, .y w h 1r w @ m@ W @ C @ O df p ►� p °a magi U z 0 U F. W O a G � N �" QS U 'coU N U NO U ya 04 O y @ N O O N C3 in 'CK y` M `� @ -J v ai .M- Z b et oCDO ro o U �°pa2 a c �a.l N�ccLo ooa y QQ@1 m 0 0 ! � k 2 } / d � § \ j � /. 733 f 2 R 6 k a §2% k® k® § k B t B 0 � U � � w k � Q % 2 ■ � B ¥ 2 a � a v W, v � § / U . 2 � a ! k � B S � ® c r ' $ o f co 7 ® i ® Cl) k 2 k R k k § ©� # ■ , ■ @ e m( % o e e a m r« i t m < 2@ k® u\ Lo= }\ R# ¢ R» ?�\ � 0 � . .. . .. .. .... ..... e E 0 K m In k co m to \ in Cl \ a 7 m« 4_ w e S 2 &% q 2 r&. � SID C%j to e to 24 - W §<D% G g 3< 2 u a u & 1 3 * Q � v � 0 U , W % k I= � f k 2 0 & £ 0 R E n # Q m ,0 t\ o J o ] o m ] / § \Z @#§ } § cl \ ƒ & \ \ \ Lo to \ \ c / CL k \ / U \ \ ) m / / \ u v m e 2 2 ¥ 2 2/ a q $ \ k } § £ \ \ @ k Q 3 t Q ?I k o Ay �. . . ...... .�........� .. . 0 El k \ k § ? k k k k\ 04 N 2. 2 ƒ \ c �to k / / ■ k / CO u a F Q / v ; W � U � . § v v uj � . 4 2 2 � T@ 2 e ® q C3 a § § 7 5 2 t k 2\ p§# I % § k) � e L: ■ \ $ 3 tir •'� ,ayMOpi n + s a • 'b�swafi s,K CERTIFICATE OF USE & OCCUPANCY TOWN OF NORTH ANDOVER Valid for 30 Days from December 8, 2016 Building Permit Number 332-16 on 9/15/20.16 Date: December 8, 2016 THIS CERTIFIES THAT THE BUILDING LOCATED ON 16 Berry Street Building Two MAY BE OCCUPIED AS First Floor 16 Units - IN ACCORDANCE WITH THE PROVISIONS OF THE MASSACHUSETTS STATE BUILDING CODE AND SUCH OTHER REGULATIONS AS MAY APPLY. Certificate Issued to: North Andover Holdings LLC 16 Berry Street North Andover, MA 01845 . �• $100.00 Receipt: 31316 Check : 3S�l 0 Final Construction Control Document • To be submitted at completion of construction by a Registered Design Professional for work per the 8h edition of the a Massachusetts State Building Code, 780 CMR, Section 107 Project Title.- '01W — 1 Property Address: vlik Project: Check one or both as applicable: ,New construction U Existiniz Constructinn MA Registration Number: E re stored deli xpiration da#e: am a 9n professional, and I have prepared or directly supervise the preparation of all design Pans, computations and specifications concerning: Architectural [ j Structural Mechanical • [ ] Fire Protection [ j Electrical [ ] Other: for the above named project. L or my designee, have performed the necessary professional services and was present at the construction site on a regular and periodic basis. To the best of my knowledge, information, and belief the work proceeded in accordance with the requirements of 780 CMR and the design documents papproved as part of the building permit and that I or my designee: Have reviewed, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. Have performed the duties for registered design professionals in 780 CMR Chapter 17, as applicable. Have been present at intervals appropriate to the stage of construction to become generally familiar with the Progress and quality of the work and to determine if the work was performed m a manner consistent with the construction documents and this code. Noticing in this document relieves the contractor of its responsibility regarding theprovisions of 780 CMR 10 7. Enter in the space to the right a "wet" or electronic signature and seal: f, HANIM- Phone nwnber: to es ' U A Building Official Name: Version 06 11 2013 Building otpicai lrse only Permit No.: Date. Final Construction Control Document To be submitted at completion of construction by a Registered Design Professional for work per the Sth edition of the Massachusetts State Building Code, 780 CMR, Section 107.6.4 Project Title: Berry Farms- Building 2 Property Address: Berry Street, North Andover MA Project: Check (x) one or both as applicable: [X 1 New construction Date: 11/02/16 ] Existing Construction Project description: New construction of a 4 story residential building over garage 1, Muzaffer Muctehitzade MA Registration Number: 32579 Expiration date: 6/30/2018 , am a registered design professional, and I have prepared or directly supervised the preparation of all design plans, specifications concemingl: computations and Architectural Structural Fire Protection X Electrical Mechanical Other: for the above named project. I certify that I, or my designee, have performed the necessary professional services and was Present at the construction site on a regular and periodic basis to determine that the work proceeded in accordance with the requirements ne : CMR and the design documents prepared by me and approved as part of the building permit and ;�- that I or my designee: • I _ Have reviewed, for conformance to this code a nd the design concept, shop by the contractor in accordance with the requirements of the construction d cum tints samples and other submittals 2. Have performed the duties for registered design professionals in 780 CMR Chapter 17, as applicable. 3_ Have been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this.code. Enter in the space to the right a "wet" or electronic signature and seal: _:a>> - r � 11114"" Phone number: (617).338-4406 Email: zade azadeengineerin2.com Building Official Use Only Building Official Name: Permit No.: Date: y r �?Vote L a Indicate with an '�' project design pians_ computations and specifications that you prepared or directly Supervised. If'other is chosen. vidc a descrigtivn. Trial Version 10_09_2012 Final Construct' _ Ion Control Document • To be submitted at Completion of _ p canstrtictlon by a Registered Design Professional for work per the 8'h edition of the 5� Massachusetts State Building Code, 780 CMR, Section 107.6.4 Project Title: Berry Farms- Building 2 Date: 11/02/16 Property Address: Berry Street, North Andover MA Project: Check (x) one or both as applicable: [X ] New construction j ] Existing Construction Project description: New construction of a 4 story residential building over garage. I, Nluzaffer Muctehitzade MA Registration Number 32574 Expiration date: 6/30/2018, am a registered design professional, and I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning': Architectural Structural Mechanical Fire Protection X Electrical (Fire Alarm) pecr for the above named project I certify that 1, or my designee, have performed the necessary professional services and was present at the construction site on a regular and periodic basis to determine that the work proceeded in accordance with the requirements of 780 CMR and the design documents prepared by me and approved as part of the building permit and that I or my designee: • 1. Dave reviewed, for conformance to this code and the design concept, shop drawings, by the contractor in accordance with the requirements of the construction documents. samples and other submittals 2. Have performed the duties for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Have been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this code. Enter in the space to the right a "wef'or electronic signature and seal: Phone number (617) 338-4406 Email. zade@zadeengineering.com Buildin.- Oficial Use Only Building— Official Name: permit iNo.: Date: Note 1. Indicate with an `x° project design plans_ computations and specifications that you prepared or directly supervised. if `other' is chosen. provide a description. • Trial Version 10 09 20 l' Final Construction on Control Document • i To be submitted at completion of construction by a A Registered Design Professional for work per the 81h edition of the Massachusetts State Building Code, 780 CMR, Section 107.6.4 Project Title: Bent' Farms- Building Date: 11/02/16 Property Address: Berry Street, North Andover NTA Project, Check (x) one or both as applicable: [X ) New construction [) Existing Construction Project description: New construction of a 4 story residential building over garage. I, Muzaffer Muctehitzade NMA Registration Number: 39362 Expiration date: 6/30/2018 , am a registered design professional, and I have prepared or directly supervised the preparation of all design pians, computations and specifications concerning,: Architectural Structural X Fire Protection Electrical Mechanical Other: for the above named project. I certify that I, or my designee, have performed the necessary professional services and was Present at the construction site on a regular and periodic basis to determine that the work proceeded in accordance with the requirements of 780 CMR and the design documents prepared by me and approved as part of the building permit and �. that I or my designee: • 1. Have reviewed, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. p 2. Have performed the duties for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Have been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this code. Enter in the space to the right a =wet" or electronic signature and seal: Phone number: (617) 338-4406 Email: zadeC,zadeen2ineerin2.com Fluildin.0 Official Use Only Buildinu Official Name-. Permit No.: Date: g ---• provide adescription.•--• r• �.. ��.`.. p.-, wLAiPdLaiwns and specifications mat You prepared or directly supervised_ Ir `outer' is chosen. r� 0 Trial Version 10 09 ?01) Final Construction Contr©l Document To be submitted at completion of constnlction by a 1 Registered Design Professional for work "1 ,. .per the 8 edition of the Massachusetts State Building Code, 780 CMR, Section 107.6.4 Project Title: Berry Farms- Building 2 Date: 11/02/16 Property Address: Berry Street, North Andover MA Project: Check (x) one or both as applicable: [X ] New construction [ ] Existing Construction Project description: New construction of a 4 story residential building over garage. 1, Mohammed Zade, MA Registration Number: 27233 Expiration date: 6/30/2018 , am a registered desig7l Professional. and 1 have prepared or directly supervised the preparation of all design plans, computations and specifications concerning': Architectural structural X Mechanical (PLUMBING) Fire Protection Electrical Other: for the above named project_ I certify that 1, or my designee, have performed the necessary professional services and was present at the construction site on a regular and periodic basis to determine that the work proceeded in accordance with the requirements of 780 CMR and the design documents prepared by me and approved as part of the building permit and that I or my designee: is 1. Have reviewed, for conformance to this code and the design concept, e p ,shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2_ Have performed the duties for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Have been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this code. Enter in the space to the right a "wet" or electronic signature and seal.- Phone eal: Phone number. (617) 338-4406 )✓mail: zade@zadeengineering.com Building Official Use only Building Official Name. permit tiro.: Date: Note L Indicate with an 'X' project design plans, computations and specifications that you prepared or directly supervised if `other' is chosen. 4rovide a description. Trial version 10092012 Final Construction Control Document To be submitted at completion of construction by a t Registered Design Professional sv=' for work -per the 811 edition of the Massachusetts State Building Code, 780 CMR, Section 107.6.4 Project Title: Bevy Farms- Building 2 Date: 11102/16 Property Address: Berry Street, North Andover NIA Project: Check (x) one or both as applicable: [X ] New construction [ ] Existing Construction Project description: New construction of a 4 story residential building over garage. 1, Mohammed Zade, MA Registration Number: 27233 Expiration date: 6/30/2018 , am a registered desi II professional, and I have prepared or directly supervised the preparation of all design plans, computations and specifications concerningi: Architectural Structural X Mechanical (HVAC) Fire Protection Electrical Other: for the above named project. I certify that I, or my designee, have performed the necessary professional services and was present at the construction site on a regular and periodic basis to determine that the work proceeded in accordance with the requirements of 780 CMR and the design documents prepared by me and approved as part of the building permit and rte: that I or my designee: 1. Rave reviewed, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contactor in accordance with the requirements of the construction documents. 2. Have performed the duties for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Have been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this code. Enter in the space to the right a "wet" or electronic signature and Seal: Phone number: (617) 338-4406 Email: zade@zadeengineering_com Building= official Use Only Building Oficial Name_ Permit No.: Date: W te I'Indicate with an 's' project design plans. compttrttions and .peri Fwations that you prcparcd or directly supervised If'other' is chosen. Vide a description. Trial version to09201 2 r --, ITI Project Title: Berry Farms Final Construction Control Document To be submitted at completion of construction by a Registered Design professional for work per the 80' edition of the Massachusetts State Building Code, 780 CMR, Section 107 Date: October 25,2016 ,Permit No. Property Address: Banding #2 -BSM Farms 16 Bg Street North Andover MA Project: Check (x) one or both as applicable: X New construction Existing Construction Project description: Construction of an affordable housing rental community consisting of four apartment buildings (Buildings 1 through 4) containing a total of 196 units. These units will be served by a total of 321 parking spaces: 191 surface spaces and 130 spaces within Buildings 2, 3 and 4. The project will be served by municipal sewer and water along with site access available from Berry Street. Stormwater runoff will be collected and conveyed to one of various stormwatcr management areas at the perimeter of the development prior to its ultimate discharge into the existing ponds or wetlands.THIS CONTROL DOCUMENT FOR BUrvn NG #2 ONLY I Douglas E Miller MA Registration Number: 33965 Expiration date: 06/30/2018 , am a registered design professional, and I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning: • Architectural Structural Mechanical Fire Protection Electrical X Other. Describe Civil Site Design for the above named project. I, or my designee, have performed the necessary professional services and was present at the construction site on a regular and periodic basis. To the best of my knowledge, information, and belief the work proceeded in accordance with the requirements of 780 CMR and the design documents approved as part of the building permit and that I or my designee: l . Have reviewed, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Have performed the duties for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Have been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this code. Nothing in this doCUIllent relieves the c011tractor Of its responsibility regarding the prow W 107. a? DOUGLAS Enter in the space to the right a "wet" or E. electronic signature and seal:MILLEP, 1( -00 -CIVIL Phone number. 978-772-1509 tuilft Official Name: v�;o„ Od 11201.3 Email: dmiiler@gpr-inc.com Pemit No.: Date: Building official Use only 0 r o+<Moera.ya t My>4c * f CERTIFICATE OF USE & OCCUPANCY TOWN OF NORTH ANDOVER Valid for 30 Days from September 22, 2016 Building Permit Number 333-2016 on 9/15/2015 Date: September 22, 2016 THIS CERTIFIES THAT THE BUILDING LOCATED ON 1.6 Berry Street — Building Three MAY BE OCCUPIED AS First Floor —14 Units IN ACCORDANCE WITH THE PROVISIONS OF THE MASSACHUSETTS STATE BUILDING CODE AND SUCH OTHER REGULATIONS AS MAY APPLY. Certificate Issued to North Andover Holdings, LLC 16 Berry Street North Andover, MA 01.845. Fee: $100.00 Receipt: 30937 Check : 263 • W*-';Nwj' E� WORIN a YS 4ao r�.� S'I[NVr � TEMPORARY CERTIFICATE OF USE & OCCUPANCY TOWN OF NORTH ANDOVER Valid for 30 Days from Septembeir 22, 2016 Building Permit Number 333-2016 on 9/15/2015 Date: September 22, :2016 THIS CERTIFIES THAT THE BUILDING LOCATED ON 16 Berry Street — Building Three MAY BE OCCUPIED AS Second Floor —14 Units IN ACCORDANCE WITH THE PROVISIONS OF THE MASSACHUSETTS STATE BUILDING CODE AND SUCH OTHER REGULATIONS AS MAY APPLY. Certificate Issued to: North Andover Holdings, LLC 16 Berry Street North Andover, MA 01845 Fee: $100-00 Receipt: 30937 Check: 263 0 TEMPORARY CERTIFICATE OF USE & OCCUPANCY TOWN OF NORTH ANDOVER Valid for 30 Days from September 22, 2016 Building Permit Number 333-2016 on 9/15/2015 Date: September 22, 2016 THIS CERTIFIES THAT THE BUILDING LOCATED ON 16 Berry Street — Building Three MAY BE OCCUPIED AS Third Floor —14 Units M ACCORDANCE WITH THE PROVISIONS OF THE MASSACHUSETTS STATE BUILDING CODE AND SUCH OTHER REGULATIONS AS MAY APPLY. • Certificate Issued to: North Andover Holdings, LLC 16 Berry Street North Andover, MA 01845 Fee. $100.00 Receipt: 30937 Check: 263 0 Final Construction Control Document To be submitted at completion of construction by a Registered Design Professional for work per the 8s' edition of the Massachusetts State Building Code, 780 CMR, Section 107 Project Title:YGr—� Date: Permit No.? J Property Address: , {- / 13W, Project: Check one or both as applicable: KNew construction U Existing Construction Project description n Ic�il1C1�1'_L �vlt'� MA Registration Number: Expiration date: am a registered design professional, and I have prepared or directly supervised the preparation of all design plan , computations and specifications concerning: �. Architectural [ ] Structural [ ] Mechanical [ ] Fire Protection [ ] Electrical [ ] Other: for the above named project. I, or my designw, have performed the necessary professional services and was present at the construction site on a regular and periodic basis. To the best of my knowledge, information, and belief the work proceeded in accordance with the requirements of 780 CMR and the design documents approved as part of the building permit and that I or my designee: 1. Have reviewed, for conformance to this code and the design concept, shop drawings; samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Have performed the duties for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Have been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this code. Nothing in this document relieves the contractor of its Enter in the space to the right a "wet" or electronic signature and seal: Phone number: Building Official Name: Version 06112013 Budding Official Use Only Peranit No.: the provisions of 780 CMR 107. Im Final Construction Control Document ji To be submitted at completion of construction by a Registered Design Professional for work per the 8'edition of the Massachusetts State Building Code, 780 CMR, Section 107 Project Title: Berry Farms — Building 3 Date:6/1/2016 Permit No. 333-2016 Property Address: Berry Street, North Andover, MA Project: Check (x) one or both as applicable: X New construction Existing Construction Project description: Apartment Building I Jeffrey S. Nawrocki MA Registration Number: 34168 Expiration date: 6/30/16 , am a registered design professional, and I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning: Architectural X Structural Mechanical Fire Protection Electrical Other_ Describe for the above named project. I, or my designee, have performed the necessary professional services and was present at the construction site on a regular and periodic basis. To the best of my knowledge, information, and belief the work �• proceeded in accordance with the requirements of 780 CMR and the design documents approved as part of the building permit and that I or my designee: 1. Have reviewed, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Have performed the duties for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Have been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 107. Enter in the space to the right a "weC or electronic signature and seal: Phone number: 603-433-8639 Ex. 206 Building Official Name: Permit No.: Version 06 11 2013 Date: oma. JEFFREY S. R+ NAWROCKt STRUCTURAL No. 34168 Email: Jeff@jsneng.com Building Offioial Use Only Final Construction Control Document To be submitted at completion of construction by a ' Registered Design Professional for work per the 8"' edition of the Massachusetts State Building Code, 780 CMR, Section 107.6.4 Project Title: Berry Farms- Building 3 Date: 08/16/2016 Property Address: Betty Street, North Andover MA Project: Check (x) one or both as applicable: [X ] New construction [ J Existing Construction Project description: New construction of a 3 story residential building over garage. I, Muzaffer Muctehitzade MA Registration Number: 32579 Expiration date: 6/30/2018 , am a registered design professional, and I have prepared or directly supervised the preparation of all design plans; computations and specifications concerning': Architectural Structural Fire Protection X Electrical Mechanical Other: for the above named project. I certify that I, or my designee, have performed the necessary professional services and was present at the construction site on a regular and periodic basis to determine that the work proceeded in accordance with r - the requirements of 780 CMR and the design documents prepared by me and approved as part of the building permit and that I or my designee: 1- Have reviewed, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Have performed the duties for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Have been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this code. Enter in the space to the right a "wet" or electronic signature and seal: Phone number. (617) 338-4406 Email: zade(a�zadeengineering.com Building Official Use Only Building Official Name: Permit No.: Date: Note 1. Indicate'Mth an `x' project design plans, computations and specifications that you prepared or directly supervised. If `other' is chosen, provide a description. Trial Version 10 09 2012 Final Construction Control Document To be submitted at completion of construction by a ' Registered Design Professional Y for work per the 8' edition of the Massachusetts State Building Code, 780 CMR, Section 107.6.4 Project Title: Berry Farms- Building 3 Date: 08/16/2016 Property Address: Berry Street, North Andover MA Project: Check (x) one or both as applicable: [X ] New construction [ ] Existing Construction Project description: New construction of a 3 story residential building over garage. I, Muzaffer Muctehitzade MA Registration Number 32579 Expiration date: 6/3012018, am a registered design professional, and I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning: Architectural Structural Fire Protection X Electrical (Fire Alarm) Mechanical Other: for the above named project. I certify that I; or my designee, have performed the necessary professional services and was present at the construction site on a regular and periodic basis to determine that the work proceeded in accordance with the requirements of 780 CMR and the design documents prepared by me and approved as part of the building permit and ,khat I or my designee: 1. Have reviewed, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Have performed the duties for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Have been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this code. Enter in the space to the right a "wet" or electronic signature and seal: Phone number: (617) 338-4406 Email: zade@zadeengineering.com Building Official Use Only Building Official Name: NrmitNo.: Date: 1. Indicate with an `x' project design plans, computations and specifications that you prepared or directly supen-ised. if `other' is chosen, 3e a description. Trial Version 10 09 2012 Final Construction Control Document �r To be submitted at completion of construction by a Registered Design Professional for work per the 8a' edition of the Massachusetts State Building Code, 780 CMR, Section 107.6.4 Project Title: Berry Farms- Building 3 Date: 08/16/2016 Property Address: Berry Street, North Andover MA Project: Check (x) one or both as applicable: [X ] New construction [ ] Existing Construction Project description: New construction of a 3 story residential building over garage. I, Muzaffer Muctehitzade MA Registration Number: 39362 Expiration date: 6[30/2018, am a registered design professional, and I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning': Architectural Structural X Fire Protection Electrical Mechanical Other: for the above named project. I certify that 1, or my designee, have performed the necessary professional services and was present at the construction site on a regular and periodic basis to determine that the work proceeded in accordance with Watthe requirements of 780 CMR and the design documents prepared by me and approved as part of the building permit and I or my designee: 1. Have reviewed, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Have performed the duties forregistered design professionals in 780 CMR Chapter 17, as applicable. 3. Have been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this code. Enter in the space to the right a "wet" or electronic signature and seal: Phone number: (617) 338-4406 Email: zade*,zadeen gin eering.com Building Official Use Only Building Official Name: PesmitNo.: Date: ` Note 1. Indicate with an `s' project design plans, computations and specifications that -you prepared or directly supervised. If 'other' is chosen, Orovide a description. Trial Version 10 09 2012 Final Construction Control Document To be submitted at completion of construction by a Registered Design Professional .� for work per the 81 edition of the Massachusetts State Building Code, 780 CMR, Section 107.6.4 Project Title: Berry Farms- Building 3 Date: 08/16/2016 Property Address: Berry Street, North Andover MA Project: Check (x) one or both as applicable: [X ] New construction j ] Existing Construction Project description: New construction of a 3 story residential building over garage. I, Mohammed Zade, MA Registration Number: 27233 Expiration date: 6/30/2018 , am a registered design professional, and I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning': Architectural Structural X Mechanical (PLUMBING) Fire Protection Electrical Other: for the above named project. I certify that I, or my designee, have performed the necessary professional services and was present at the construction site on a regular and periodic basis to determine that the work proceeded in accordance with •the requirements of 780 CMR and the design documents prepared by me and approved as part of the building permit and that I or my designee: 1. Have reviewed, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Have performed.the duties for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Have been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this code. Enter in the space to the right a "wet' or electronic signature and seal: Phone number: (617) 338-4406 Email: zade@zadeengineering:com Building Official Use Only Building Official Name: PermitNo.: Date: 2 Note 1. Indicate with an `x' project design plans, computations and specifications that you prepared or directly supervised. If `other' is chosen, provide a description. Trial Version 10 09 2012 Final Construction Control Document To be submitted at completion of construction by a ° Registered Design Professional \\ for work per the 8a' edition of the Massachusetts State Building Code, 780 CMR, Section 107.6.4 Project Title: Berry Farms- Building 3 Date: 08/16/2016 Property Address: Berry Street, North Andover MA Project: Check (x) one or both as applicable: [X ] New construction [ ] Existing Construction Project description: New construction of a 3 story residential building over garage. I, Mohammed Zade, MA Registration Number: 27233 Expiration dater 6/30/2018 ,gin a registered design prgfessional, and I have prepared or directly supervised the preparation. of all design plans, computations and specifications concerning': Architectural Structural X Mechanical (HVAC) Fire Protection Electrical Other: for the above named project. I certify that 1, or my designee, have performed the necessary professional services and was present at the construction site on a regular and periodic basis to determine that the work proceeded in accordance with :— the requirements of 780 CMR and the design documents prepared by me and approved as part of the building permit and *at I or my designee: 1. Have reviewed, for conformance to this code and the design concept, shop drawings,, samples and other submittals by the contractor in accordance with the requirements of the construction documents. I Have performed the duties for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Have been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this code. Enter in the space to the right a "wet" or electronic signature and seal: Phone number: (617) 338-4406 Email: zade@zadeengineering.com Building Official Use Only Official Name: Permit No.: Date: ote 1. Indicate 1writh an Y project design plans, computations and specifications that you prepared or directly supervised. If `other' is chosen, provide a description. Trial Version 10 04 2012 Final Construction Control Document To be submitted at completion of construction by a Registered Design Professional for work per the 8a' edition of the J Massachusetts State Building Code, 780 CMR, Section 107 Project Title: Berry Farms Date: September 8, 2016 Permit No. Property Address: Building #3; Berry Farms, 16 Berry Street North Andover MA Project: Check (x) one orboth as applicable: X New construction Existing Construction Project description: Construction of an affordable housing rental community consisting of four apartment buildings (Buildings 1 through 4) containing a total of 196 units. These units will be served by a total of 321 parking spaces 191 surface spaces and 130 spaces within Buildings 2,3 and 4. The project will be served by municipal sewer and water along with site access available from Berry Street. Stormwater runoff will be collected and conveyed to one of various stormwater management areas at the perimeter of the development prior to its ultimate discharge into the existing ponds or wetlands.TMS CONTROL DOCUMENT FOR BUILDING #3 ONLY I Douglas E. Miller MA Registration Number: 33965 Expiration date: 06/30/2018 , am a registered design professional, and I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning: Architectural Structural Mechanical Fire Protection Electrical X Other: Describe Civil Site Design for the above named project. I, or my designee, have performed the necessary professional services and was present at the construction site on a regular and periodic basis. To the best of my knowledge, information, and belief the work proceeded in accordance with the requirements of 780 CMR and the design documents approved as part of the building permit and that I or my designee: 1. Have reviewed, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Have performed the duties for registered design professionals in 780 CMR Chapter 17; as applicable. 3. Have been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this code. Nothing in this document relieves the contractor of its responsibility regarding the pro ' * 7 0 CMR 107. �'ttk OF &t4,7�t, Enter in the space to the right a "wet' or a2 DO E U►5 �1P electronic signature and seal: 2 MILLER "4 U CIVIL c n� ��Nts.33CAS Q' f .G Phone number: 978-772-1509 Email: diniller@gpr-inc.com t� Building Official Name: Permit No.. Vcrsion 06 11 2013 Date: Building Official Use Only 24 Ladd Street, Portsmouth, NH 03801 PILOT CONSTRUCTION, INC. WARRANTY $ PROCEDURE for Berry Farm — North Andover, MA In accordance with the Contract Documents Pilot Construction, Inc., shall warranty all work for Building # 3 (30 Berry Street) of the project known as Berry Farm for a period of one-year starting on September-22ffi, 2016, and ending on September 21'", 2017. It is our preference that all warranty claims initiated by the Owner follow the following procedures after an evaluation by your on-site Maintenance: 9. Utilizing the Subcontractor Contact List, attached, notify the trade determined to be responsible, in writing preferably. Z. If no response is received from the responsible trade within three working days, notify Pilot Construction, Inc. at their Portsmouth, New Hampshire office in writing at fax: (603-436-3946). 3. If there is any confusion regarding which trade may be responsible for a warranty item, notify Pilot Construction, Inc. for direction. If at any time there is a need of assistance with the execution of the repair of a warranty item, please do not hesitate to contact Pilot Construction, Inc., to facilitate the process. PILOT CONSTRUCTION, INC. Gerald ransen, Project Manager Date .7 C7 • 0 E61i EOIi Cfl' ir+i iOi iOi Ef+')E im-i ErN sni iN iN ri:o; iW; :v iOli:Wi iN; ;Lr): ;h-: ter): iM� ir,: pry)j :(N Ni :N iM iE+, i.-fE iOi irii .n. ifr]C in i:fl �, �.; �, • :W: .._ . i i EVi i4}iNE 47Ec C i x'41 � U' C til : U: � E G�ii aj iO' iZtQi E�i�E i+E i� C. 0i Z. :tib U: i EQ 4' Q : CL: V! : •.ui Eu` �. .........................:.....5....5....5....5.... : ; w • �+ E ...... E ti -- ---- - ui ...... EE : o: o:.: ,�: ass : �: EWE _ E� EF,E 4 iU: ii VE LE THE itOEoE ' i4)i�i iGlE C, aX7 Ewi :ME iRi ERE ,Q; :N. Ni i 0E ilpi ibk Q1W Eli iNi i Li :1 io iCL:Q) i�.E :�: o:�z; rn 4 C' r te' LU: i :� �6 •x: a�ii�` : G3iiM`� , m?canis E�O;N i � EQi ;gE :ro: :>� "''z ° �: mi Z: !Ci�iv : of :C:oE� : min: ='• Ql�E :6 d:o Esty rts• iO: ro: • r � uii :�vs m: �: :`o •:, a i - :w;s�E a °' ~ o m Eu O .... - - :Nl�o:oE i ! E Eti .� •gyp '� '� W 0 0 0 UA; IM: uj Lu e.m:i 'u: U� i ko ro! m: holo: V �j! Oi ><i -------------- (31 n tn cl) Lf) i cLj !&:m: . : . . . .co . . : . "Q . .LO: co: rn: M: 00: r4: o;o1rn (A i M — ro! m: holo: V �j! Oi ><i -------------- ........... } } \� : } { :��� ' } (31 tn cl) Lf) i cLj i(Li ralcory) : i C: 04 i 00: r4: o;o1rn (A i M — : ;oi th -13 CQ 7;%\!2(Ei to:jul LL: ........... } } \� : } { :��� ' } Ot.µ0A7Jr �1 aFi CERTIFICATE OF USE & OCCUPANCY TOWN OF NORTH ANDOVER Valid for 30 Days from March 22, 2017 Building Permit Number 334-20.16 on 9/15/2015 Date: March 22, 2017 THIS CERTIFIES THAT THE BUILDING LOCATED ON 16 Berry Street MAY BE OCCUPIED AS Building 4, First Floor IN ACCORDANCE WITH THE PROVISIONS OF THE MASSACHUSETTS STATE BUILDING CODE AND SUCH OTHER REGULATIONS AS MAY APPLY. • Certificate Issued to: North Andover Holdings LLC 16 Berry Street North Andover, MA 01845 Fee: $100.00 Receipt: 31611 Check: 408 CJ TEMPORARY CERTIFICATE OF USE & OCCUPANCY TOWN OF NORTH ANDOVER Valid for 30 Days from March 22, 2017 Building Permit Number 334-2016 on 9/15/15 Date: March 22, 2017 THIS CERTIFIES THAT THE BUILDING LOCATED ON 16 Berry Street MAY BE OCCUPIED AS Building Four — Second Floor IN ACCORDANCE WITH THE PROVISIONS OF THE MASSACHUSETTS STATE BUILDING CODE AND SUCH OTHER REGULATIONS AS MAY APPLY. • Certificate Issued to: North Andover Holdings, LLC 16 Berry Street North Andover, MA 01845 s. VA 0", tee.— Aall Fee: $100.00 Receipt: 31611 Cheek: 408 TEMPORARY CERTIFICATE OF USE & OCCUPANCY TOWN OF NORTH ANDOVER Valid for 30 Days from 3/22/2017 Building Permit Number 334-2016 ON 9/15/15 Date: March 22, 2017 THIS CERTIFIES THAT THE BUILDING LOCATED ON 16 Berry Street MAY BE OCCUPIED AS Building 4, Third Floor IN ACCORDANCE WITH THE PROVISIONS OF THE MASSACHUSETTS STATE BUILDING CODE AND SUCH OTHER REGULATIONS AS MAY APPLY. Certificate Issued to: North Andover Holdings, LLC 16 Berry Street North Andover, MA 01845 Fee: $100.00 Receipt: 31611 Check: 408 0 TEMPORARY CERTIFICATE OF USE & OCCUPANCY TOWN OF NORTH ANDOVER Valid for 30 Days from March 22, 2017 Building Permit Number 334-2016 ON 9115115 Date: March 22, 2017 THIS CERTIFIES THAT THE BUILDING LOCATED ON 16 Berry Street MAY BE OCCUPIED AS Building 4, Fourth Floor IN ACCORDANCE WITH THE PROVISIONS OF THE MASSACHUSETTS STATE BUILDING CODE AND SUCH OTHER REGULATIONS AS MAY APPLY. Certificate Issued to: North Andover Holdings, LLC 16 Berry Street North Andover, MA 01845 Fee: $100.00 Receipt: 31611 Check: 408 0 s i � 1* •' i CERTIFICATE OF USE & OCCUPANCY TOWN OF NORTH ANDOVER Valid for 30 Days from January 20, 2017 Building Permit Number 334-2016 on 9/15/2015 Date: January 20, 2017 THIS CERTIFIES THAT THE BUILDING LOCATED ON 16 Berry Street MAY BE OCCUPIED AS Building 4, First Floor IN ACCORDANCE WITH THE PROVISIONS OF THE MASSACHUSETTS STATE BUILDING CODE AND SUCH OTHER REGULATIONS AS MAY APPLY. • Certificate Issued to: North Andover Holdings LLC 16 Berry Street North Andover, MA 01845 ' r ,11, IN w g Inspector Fee: $100.00 Receipt: 31466 Check: 363 Baal Construction Contr®i Document To be submitted at completion of construction by a Registered Design Professional for work per the 0 edition of the Massachusetts State Building Code, 780 CMR, Section 107 123 Project Tins: KYYLX C614 t nit Date- 1 1 t'i Penuit iso.J*,J t (e Property Address: c'GVYU c• # Mri (Jly Project: Check me or both as applicable: (' U New w constrLwtion U Existing Construction Project description Y"Jr— Y�►4�1aCe1 a A' t t _fit" n L irir�iA ill VI d MA Registration Number P�,. am a registered design professiorual and I have prepared or directly supervised the preparation of all design Plans, computations and specifications concerning: Architectural i Struck [ ] Mechanical [ j Fire Protection [ ] Electrical [ 1 Other: for the above named project L or my designee, have performed the necessary professional services and was preset at the construction tion sske on a regular and, periodic basis. To the best of my knowledge, infimn :iot4 and belief the work proceeded in accordance with the requirements of 780 CMR and the design documents approved as part of the building permit and that I or any designee: 1. Have reviewed, for conformance to this code and the design concept, shop Vis, samples and other submittals by the contractor in accordance with the requirements of the constriction documents. 2. Have performed the hies for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Have bee- present at intervals sMopriatae to the stage of construction to become gener&y familiar with the Frogre'ss and qualify of the work and to determine if the work was performed in a manner cwsistmi with the construction documents and this code. Nothing in this document relieves the contractor of its responsibility regarding the provisions of 780 CMR 107. Enter in the space to the right a "wet" or electronic signal and seal: Phone number: F�1 - .Fnnatk ai( .�• T BUMW ofrMCMdNMe Version 06 It 2013 $nig Offs iaiUx Only Penuit W. - Date: Final Construction Control Document To be submitted at completion of construction by a 1 d Registered Design Professional L for work per the 8' edition of the 5`t�v Massachusetts State Building Code, 780 CMR, Section 107.6.4 roject Title: Berry Farms- Building 4 Date: 12/16/16 roperty Address: Berry Street, North Andover MA roject: Check (x) one or both as applicable: [X ] New construction [ ] Existing Construction ?roject description: New construction of a 4 story residential building over garage. , Muzaffer Muctehitzade MA Registration Number: 32579 Expiration date: 6/30/2018 , aux a registered design professional, and I have prepared or directly supervised the preparation of all design plans, computations and pecifications concerning': Architectural Structural Fire Protection X Electrical Mechanical Other; br the above named project. I certify that I or my designee, have performed the necessary professional services and was ►resent at the construction site on a regular and periodic basis to determine that the work proceeded in accordance with he re uirements of 780 CMR and the design documents prepared by me and approved as part of the building permit and uir designee: 1. Have reviewed, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Have performed the duties for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Have been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this code. enter in the space to the right a "wet" or ;lectronic signature and seal: ?hone number: (617) 338-4406 Email: zade�zadeengineerin .ewer Building Official Use Only Name- Permit No.: Date: 'Iot 71ndicate with an `x' project design plans, computations and specifications that you prepared or directly supervised. If `other' is chosen, provide a description. Trial Version 10 09 2012 Final Construction Control Document To be submitted at completion of construction by a d Registered Design Professional for work per the 8' edWon of the Massachusetts State Building Code, 780 CMR, Section 107.6.4 -oject Title: Berry Farms- Building 4 Date: 12/16/16 -operty Address: Berry Street, North Andover MA ,-oject: Check (x) one or both as applicable: [X ] New construction [ ] Existing Construction 'roject description: New construction of a 4 story residential building over garage. Muzaffer Muctehitzade MA Registration Number: 39362 Expiration date: 6/30/2018 , am a registered design ,ofessional, and I have prepared or directly supervised the preparation of all design plans, computations and )ecifications concerning': Architectural Structural X Fire Protection Electrical Mechanical Other: ►r the above named project. I certify that I, or my designee, have performed the necessary professional services and was resent at the construction site on a regular and periodic basis to determine that the work proceeded in accordance with t�e requirements of 780 CMR and the design documents prepared by me and approved as part of the building permit and —*y designee: 1. Have reviewed, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Have performed the duties for registered design professionals in 780 CMR Chapter 17, as applicable. I Have been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this code_ iter in the space to the right a "wet" or ectronic signature and seal: lone number: (617) 338-4406 Email: zade@zadeengineering.com Building Official Use Only ulding Official Name: Permit No.: Date: icate w th an`X' project design plans, computations and specifications that you prepared or directly supervised. If `other' is chosen, V Wscription. ial Version t0 09 2012 :; Y3 Final Construction Control Document To be submitted at completion of construction by a Registered Design Professional h for work per the 8' edition of the Massachusetts State Building Code, 780 CMR, Section 107.6.4 -oject Title:- Berry Farms- Building 4 Date: 12/16116 roperty Address: Berry Street, North Andover MA roject: Check (x) one or both as applicable: [X 1 New construction [ ] Existing Construction 'roject description: New construction of a 4 story residential building over garage. Mohammed Zade, MA Registration Number: 27233 Expiration date: 6/3012018 , am a registered design rofessional, and I have prepared or directly supervised the preparation of all design plans, computations and )ecifications concerning': Architectural Structural X Mechanical (PLUMBING) Fire Protection Electrical Other: >r the above named project. I certify that I, or my designee, have performed the necessary professional services and was resent at the construction site on a regular and periodic basis to determine that the work proceeded in accordance with to .requirements of 780 CMR and the design documents prepared by me and approved as part of the building permit and --*y designee: 1- Have reviewed, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Have performed the dirties for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Have been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this code. Liter in the space to the right a "wet" or eetronie signature and seal: hone number: (617) 338-4406 Fanail: zade@zadeengineering.com Building Official Use Only Official Name: Permit No.: Date_ locate with an 'x' project design plans, computations and specifications that you prepared or directly supervised. If `other' is chosen, ovine a description iai Version 10092012 Final Construction Control Document To be submitted at completion of construction by a d Registered Design Professional for work per the 8' edition of the Massachusetts State Building Code, 780 CMR, Section 107.6.4 roject Title: Berry Farms-- Building 4 Date: 12/16/16 roperty Address: Berry Street, North Andover MA roject: Check (x) one or both as applicable: [X ] New construction [ ] Existing Construction 'roject description: New construction of a 4 story residential building over garage. Mohammed Zade, MA Registration Number: 27233 Expiration date: 6/30/2018 , am a registered design rofessional, and I have prepared or directly supervised the preparation of all design plans, computations and iccifications concerning': Architectural Structural X Mechanical (HVAC) Fire Protection Electrical Other: )r the above named project. I certify that I, or my designee, have performed the necessary professional services and was resent at the construction site on a regular and periodic basis to determine that the work proceeded in accordance with �e uirenments of 780 CMR and the design documents prepared by me and approved as part of the building permit and I _Wy designee: 1. Have reviewed, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Have performed the duties for registered design professionals in 780 CMR Chapter 17, as applicable. I Have been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this code. nter in the space to the right a "wet" or ectronic signature and seal: hone number: (617) 338-4406 Email: zade@,zadeenginecring.com Building Official Use Only Name: PemiitNo.: Date: MDRANWEP �?;pE ote ..indicate with an `x' project design plans, computations and specifications that you prepared or directly supervised. If `other' is chosen, ovide a description. iai Version 10 09 2012 Final Construction Control Document To be submitted at completion of construction by a W Registered Design Professional for work per the 8a' edition of the i M sYD V Massachusetts State Building Code, 780 CMR, Section 107 Project Title: Berry Farms Date:December 13, 2016 Permit N Property Address: Building #4 Berry Farms, 16 Berry Street, North Andover, MA Project: Check (x) one or both as applicable: X New construction Existing Construction Project description: Construction of an affordable housing rental community consisting of four apartment buildings (Buildings 1 through 4) containing a total of 196 units. These units will be served by a total of 321 parking spaces: 191 surface spaces and 130 spaces within Buildings 2, 3 and 4. The project will be served by municipal sewer and water along with site access available from Berry Street. Stormwater runoff will be collected and conveyed to one of various stormwater management areas at the perimeter of the development prior to its ultimate discharge into the existing ponds or wetlands.TFIIS CONTROL DOCUMENT FOR BUILDII 1G #4 ONLY I Douglas E. Miller MA Registration Number: 33965 Expiration date: 06/30/2018 , am a registered design professional, and I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning: Architectural Structural Mechanical Fire Protection Electrical X Other: Describe Civil Site Design for the above named project. I, or my designee, have performed the necessary professional services and was present at the construction site on a regular and periodic basis. To the best of my knowledge, information, and belief the work proceeded in accordance with the requirements of 780 CMR and the design documents approved as part of the building permit and that I or my designee: 1. Have reviewed, for conformance to this code and the design concept, shop drawings, samples and other submittals by the contractor in accordance with the requirements of the construction documents. 2. Have performed the duties for registered design professionals in 780 CMR Chapter 17, as applicable. 3. Have been present at intervals appropriate to the stage of construction to become generally familiar with the progress and quality of the work and to determine if the work was performed in a manner consistent with the construction documents and this code. Nothing in this document relieves the contractor of its responsibility regarding the pro ' , WR 107. Enter in the space to the right a "wet" or MILER aw electronic signature and seal: Phone number: 978-772-1509 Email: dmiller@gpr-inc.com Ilk Building Official Use Only Building Official Name: Permit No.: Date: Version 06 11 2013