° `March 20, 2003
Mr: D..RobertNicetta
Town "of North Andover ,' .
Building Commissioner.
27 -Charles St
North Andover,. .
Kittredge Crossing
Building #2 &. 3,Plan Review Concerns _
D,e r. Nicetta: ,
We: are'in receipt of your list of questions afteryour'review of Buildings .2 and 3 and we offer.the'following in
response:
1. Your concern with the adaptability of•each unit:
a." Blocking:,will be installed within, the walls of each bathroom for future adaptability. We have'
enclosed a detaile&ske,tch of the locations of this.blocking for your use: (Attachment #l)'
b'.:Our engiineer,'.Bob Jennings"of Mechanical Innovations, Inc., has "spoken`with Thomas Hopkins .
' of the Mass. Architectural,Access"Board. As a result,"`we have revised Bathroom Details 3;.4; &:
6.on Drawing A8'to provide the proper clearance and adaptability in .those bathrooms. Sketches
of the revised.bathroonis are enclosed for your record. (Attachment #2)
2.. We have enclosed -a copy,of the. Mass: EnergyCode,"for Buildings 2'& 3'.' (Attachment #3)
3. The demising wall between units (Type 3) is a 3 5/8" 25 GA metal studs'24" OC with resilient furring
and l ,layer of 5/8" GWR on one side and 2.layers of 5/8" GWB on the other side. It also has sound,
insulation and is a full height partition, providing a STC. rating. of 55. This Wallis designed under UL' > -
AssemblyU419. ,
-4. The attachment of the false chimney has been submitted to our structural engineer (JSN Associates) and '
revised:. We have.included a sketch.of the revision for your,reference: (Attachment. #4)
5. `Kitchen wall cabinets -will be supported with in -wall blocking as shown on the sketch enclosed herein.'
:(Attachment"#1) Base cabinets will ;be secured to the wall with.blockirig as "described ori Detail3 -on-
drawing
ndrawing A-20:
6..: We offer the following to address your structural concerns: .
"a. John Turner Consulting has been engaged to, perform torque and weld te'sti4 We will. forward
Y
'those reports upon receipt.'
,b. 7Welder Certifications are enclosed herein for your reference. (Attachment #5),
c: Control Construction 'reports will continue to:be delivered for'your review on the .Tuesday
following the inspection:
,d: W,e have enclosed a copy of the joist and bridging information. (Attachment #6)
7.I We' have enclosed the stamped roof truss design inforniation,as requested. Truss T3 shows the framed
'67
opening for the elevator shaft. (Attachment #7)
8.All-Simpson hold-down clips will be attached per manufacturer's recommendations