Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Miscellaneous - Exception (30)
Kanayo Lala, P.E. .............03/03/2014 PROJECT: Merrimack Condominiums F -TYPE EE -Compass Point, N Andover, MA DESIGN FOR - GIRDERS/JOISTS /RAFTERS Attic Beam A2 MOMENT2= 0 LB -FT 49.91 =S provided Supporting Attic Floor S= 34.36 IN^3 230.84 = I Deflection = 0.466 IN = U 309 For Total Load Required U240 Deflection2 = LOADS: DEAD LOAD 15.00 PSF 153.75 PLF Ce= 1 CF= 1.00 SNOW LOAD PSF 0.00 PLF Cq= 1 Cs= LIVE LOAD 30.00 PSF 307.50 PLF qs= 29.10 Cd= 1 TOTAL LOAD 461 PLF 1= 1 Cm= 1 WIND SPEED 100 MPH 29.10 PSF POINT LOAD LBS FT Ra= 0 LBS 2768 LB =TOTAL REACTION TRIBUTARY WIDTH 10.25 LF E= 2000000 PSI JOIST/GIRDER SPAN 12 LF Fb= 2900 PSI WIDTH- IN 3.50 PSULVL 9.25 IN = d Fv= 285 PSI ROOF PITCH - N:12 = Fc-- 2700 PSI Fcp= 750 PSI MOMENT= 8303 LB -FT MOMENT2= 0 LB -FT 49.91 =S provided OK S= 34.36 IN^3 230.84 = I Deflection = 0.466 IN = U 309 For Total Load Required U240 Deflection2 = 0.000 IN = U 463 For Live Load Required 0360 Fcp'= 527 PSI OK 1.50 In Bearing Length Fv'= 128 PSI OK KANAYa gnu No. 337160