Loading...
HomeMy WebLinkAboutMiscellaneous - Exception (204)Riverbend Crossing North Andover, MA Automatic Fire Sprinkler System Installation Xcel Fire Protection, Inc. j_a r 00 ROSEWOOD CONSTRUCTION CORPORATION 259 Turnpike Road Suite 106 Southborough, MA 01772 Phone: (508) 485-5333 Fax: (508) 485-9299 TO VB 129'7erlAA i41 WE ARE SENDING YOU Attached ❑ Under- separate cover via ❑ Shop drawings ❑ Prints ❑ Plans ❑ Copy of letter ❑ Change order ❑ ❑ Samples the following items: ❑ Specifications DESCRIPTION FARi _:/J" /, •/mss_. W Pr ow �-.t-.1►/►- ----MM THESE ARE TRANSMITTED as checked below: ❑ For approval ❑ Approved as submitted ❑ For your use ❑ Approved as noted XAs requested ❑ Returned for corrections ❑ For review and comment ❑ ❑ FORBIDS DUE REMARKS COPY TO ❑ Resubmit copies for approval ❑ Submit copies for distribution ❑ Return corrected prints ❑ PRINTS RETURNED AFTER LOAN TO US SIGNED: 7izo_ �' — if enclosures are not as noted, kindly notify us at one . X cel F ire P rotection, I nc. Fire Sprinkler Installation, Sales and Service Riverbend Crossing Green Street North Andover, MA Fire Protection Sprinkler Installation Table of Contents t(D, XFP Project #2003-008 1.) Hydraulic Calculations............................................................. Section 1 2.) Material Design Data Sheets.............................................................. Section 2 T P 11 A Industrial Way, Unit 1, Salem, NH 03079 •1-603-890-3331 • 1-800-537-3331 ' Fax: 1-603-898-9999 X cel I` ire P rotection, I nc. Fire Sprinkler Installation, Sales and Service Hydraulic Calculations 0 X 11 A Industrial Way, Unit 1, Salem, NH 03079 •1-603-890-3331 01-800-537-3331 ' Fax: 1-603-898-9999 101 L _ . _ Fire Protection by Computer Design Xcel Fire Protection Inc. 11A Industrial Way Salem Nh 03079 800-537-3331 Job Name RIVERBEND DRY Building RIVERBEND HOUSING Location GREENE STREET, NORTH ANDOVER System 1 OF 5 Contract 2003-008 Data File RIVER.WXD Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Xcel Fire Protection Inc. Page 1 RIVERBEND DRY Date 031203 Hydraulic Desiqn Information Sheet Name - RIVERBEND Date - 03/14/03 Location - GREENE STREET, NORTH ANDOVER 0 Building - RIVERBEND HOUSING System No. - 1 OF 5 Contractor- XCEL FIRE PROTECTION Contract No. - 2003-008 Calculated By - XCEL FIRE PROTECTION Drawing No. - 1 OF 5 Construction: ( ) Combustible (X) Non -Combustible Ceiling Height - 8'-6" Occupancy - PARKING GARAGE S (X) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. (X) 1 ( ) 2 ( ) 3 ( ) Ex. Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Rul pg � ,,�, f Made By Date E M Area of.,Sprn-kler-Operat ion - 1968 System Type Sprinkler/Nozzle Densityh �'�C`, 1 - .15 ( ) We t Make CENTRAL � cd •" " j D Area Per^SpYinkl' r t _-,r - 120 MAX (X) Dr y Model BV -QR E Elevation �at��Highe s� 0,11et- 8'-3" ( ) De luge Size 1/2" S Hose Allowance'y Inside )�' - 0 ( ) Pr eaction K -Factor 5.6 I Rack Spr:inkl'er Allowance - 0 ( ) Ot her Temp.Rat.155 G Hose Alhowance_rr0utside - 250 Na+""f3:A1'et'� t Note Calculation Flow Required - 679.99 Press Required - 62.874 At Test Summary C -Factor Used: 100 Overhead 140 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Cap. - T Time of Test - Rated Cap.- Elev.- O E Static Press - 86 @ Press - R Residual Press - 62 Elev. - Well Flow - 1040 Proof Flow S Elevation - 0 U P Location - GREENE STREET P L Source of Information - Y C Commodity Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled o Pallet ized o Rack M ( ) Single Row ( ) C onven. Pallet ( ) Au to. Storage ( ) Enca p. S R ( ) Double Row ( ) S lave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) 0 pen Shelf 0 C R K Flue Spacing Clearanc e: Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 .J _T Q 7 n U c O Q d Z wN L_ W LL � w X0� I- 00 O Cl) O Q U) D 2 Z E m c ac9n-��c�a CL 0) OO O 00 M N N N �O NCO .. .. .. .. .. .. .. C co f6 co O L n� O 00 Qi cLLd>, c0 c oE EU E E•� a� �>>,¢�a� w (n U) "' ' Cl) w c �,a - CV N-0 O M (p (n O O O O 0 v O O O < >Z O N :i J LL O O O a o CD ddo w (O N O 00 (0 r- .. M O (=p O 0 in 03 (O Na LL LInR'� 4 o O i N fpNN :U Y 0 LO 0 0 0 0 0 V co N — O O O O O O O o O O U — — r — — O M I-- (0 In �t M N �- m w (n (n Er w I- 00 O Cl) O Q U) D 2 Z E m c Fittings Summary Xcel Fire Protection Inc. RIVERBEND DRY Fitting Legend Page 3 Date 031203 Name A Generic Alarm Va B Generic Butterfly Valve C Roll Groove Coupling D Dry Pipe Valve E 90' Standard Elbow F 45' Elbow G Gate Valve H 45' Grvd-Vic Elbow I 90' Grvd=Vic Elbow J 90' Grvd-Vic Tee K Detector Check Valve L Long Turn Elbow M Medium Turn Elbow N PVC Standard Elbow O PVC Tee Branch P PVC 45' Elbow Q Flow Control Valve R PVC Coupling/Run Tee S Swing Check Valve T 90' Flow thru Tee U 45' Firelock Elbow V 90' Firelock Elbow W Wafer Check Valve X 90' Firelock Tee Y Mechanical Tee Z Flow Switch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Summary Xcel Fire Protection Inc. RIVERBEND DRY Page 4 Date 031203 Unadjusted Fittings Table 27.0 29.0 1/2 3/4 1 1 1/4 1 1/2 2 21/2 3 31/2 4 C 1.0 1.0 1.0 1.0 1.0 1.0 A 1.0 1.0 1.0 D 7.7 21.5 17.0 B 7.0 10.0 18.0 12.0 C 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 D 13.0 17.0 19.0 21.0 9.5 17.0 G 2.0 28.0 E 2.0 2.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 F 1.0 1.0 1.0 1.0 2.0 2.0 3.0 3.0 3.0 4.0 G 10.0 13.0 17.0 1.0 1.0 1.0 1.0 2.0 H 1.0 1.5 2.0 2.0 3.0 3.0 3.5 3.5 1 2.0 3.0 4.0 3.5 6.0 5.0 8.0 7.0 J 4.5 6.0 8.0 8.5 10.8 13.0 17.0 16.0 K 30.0 34.0 40.0 M 10.0 12.0 14.0 19.0 14.0 L 1.0 1.0 2.0 2.0 2.0 3.0 4.0 5.0 5.0 6.0 M 2.0 2.0 3.0 3.0 4.0 5.0 6.0 6.0 8.0 N 7.0 7.0 7.0 8.0 9.0 11.0 12.0 13.0 P O 3.0 3.0 5.0 6.0 8.0 10.0 12.0 15.0 Q P 1.0 1.0 1.0 2.0 2.0 2.0 3.0 4.0 Q 18.0 29.0 35.0 R 1.0 1.0 1.0 1.0 1.0 1.0 2.0 2.0 87.0 98.0 S 4.0 5.0 5.0 7.0 9.0 11.0 14.0 16.0 19.0 22.0 T 3.0 4.0 5.0 6.0 8.0 10.0 12.0 15.0 17.0 20.0 U 1.8 2.2 2.6 3.4 V 3.5 4.3 5.0 - 31.8 6.8 W X 21.0 25.0 10.3 X 8.5 10.8 13.0 Y 16.0 Y 2.0 4.0 5.0 6.0 8.0 10.5 12.5 15.5 22.0 Z 2.0 2.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 5 6 8 10 12 14 16 18 20 24 A 17.0 27.0 29.0 B 9.0 10.0 12.0 19.0 21.0 C 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 D 47.0 E 12.0 14.0 18.0 22.0 27.0 35.0 40.0 45.0 50.0 61.0 F 5.0 7.0 9.0 11.0 13.0 17.0 19.0 21.0 24.0 28.0 G 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 11.0 13.0 H 4.5 5.0 6.5 8.5 10.0 18.0 20.0 23.0 25.0 30.0 1 8.5 10.0 13.0 17.0 20.0 23.0 25.0 33.0 36.0 40.0 J 21.0 25.0 33.0 41.0 50.0 65.0 78.0 88.0 98.0 120.0 K 36.0 55.0 45.0 L 8.0 9.0 13.0 16.0 18.0 24.0 27.0 30.0 34.0 40.0 M 10.0 12.0 16.0 19.0 22.0 N O P Q 33.0 R S 27.0 32.0 45.0 55.0 65.0 76.0 87.0 98.0 109.0 130.0 T 25.0 30.0 35.0 50.0 60.0 71.0 81.0 91.0 101.0 121.0 U 4.2 5.0 5.0 V 8.5 10.0 13.0 W 13.1 31.8 35.8 27.4 X 21.0 25.0 33.0 Y Z 12.0 14.0 18.0 22.0 27.0 35.0 40.0 45.0 50.0 61.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD Xcel Fire Protection Inc. Page 5 RIVERBEND DRY Date 031203 Node Elevation K -Fact Pt Pn Flow Density Area Press No. Actual Actual Req. S001 8.5 5.6 10.33 na 18.0 .1500 120 7.000 S002 8.5 5.6 10.33 na 18.0 .1500 120.00 7.000 S003 8.5 5.6 7.0 na 14.82 .1500 98 7.000 S004 8.5 5.6 7.0 na 14.82 .1500 98 7.000 S005 8.5 5.6 8.84 na 16.65 .1500 111 7.000 S006 8.5 5.6 7.61 na 15.45 .1500 103 7.000 129 8.5 5.6 17.54 na 23.45 .10 25 7.000 125 8.5 K = K @ E005 9.53 na 17.08 126 8.5 K = K @ EQ03 10.89 na 17.98 127 8.5 K = K @ EQ06 16.04 na 21.82 128 8.5 K = K @ EQ03 18.36 na 23.34 121 8.5 K = K @ EQ05 9.54 na 17.09 122 8.5 K = K @ EQ02 10.9 na 18.0 123 8.5 K = K @ EQ06 16.06 na 21.83 124 8.5 K = K @ EQ03 18.39 na 23.36 120 8.5 5.6 19.5 na 24.73 .10 25 7.000 113 8.5 K = K @ EQ04 9.3 na 16.87 114 8.5 K = K @ EQ03 10.63 na 17.76 115 8.5 K = K @ E003 15.67 na 21.56 116 8.5 K = K @ EQ03 17.94 na 23.07 117 8.5 20.13 na 118 8.5 20.19 na 119 8.5 20.6 na 109 8.5 K = K @ EQ05 11.48 na 18.75 110 8.5 K = K @ EQ02 13.1 na 19.73 111 8.5 K = K @ EQ02 19.22 na 23.89 112 8.5 23.15 na 100 8.5 K = K @ EQ03 9.41 na 16.71 101 8.5 K = K @ EQ04 10.72 na 18.11 102 8.5 K = K @ EQ02 15.81 na 21.67 103 8.5 K = K @ EQ02 18.1 na 23.19 104 8.5 20.31 na 105 8.5 20.63 na 106 8.5 20.96 na 107 8.5 24.6 na 108 8.5 25.14 na 200 8.5 41.72 na DPV 8.5 50.89 na BOR 2.0 56.05 na TOU 2.0 61.05 na HOSE 0.0 62.27 na 250.0 TEST 0.0 62.87 na The maximum velocity is 16.53 and it occurs in the pipe between nodes 108 and 200 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 E* M Final Calculations - Standard 15.45 1.049 1T 3.568 0.250 Xcel Fire Protection Inc. K Factor = 5.60 to 100 Page 6 RIVERBEND DRY 0.0 EQ06 15.45 0.1131 Date 031203 Hyd. Qa Dia. Fitting Pipe Pt Pt "C" or Ftng's Pe Pv *" '*` Notes t Qt Pf/UL Eqv. Ln. Total Pf Pn SOW 18.00 1.049 1E 1.427 0.250 10.332 K Factor = 5.60 to 100 100 1.428 0.0 4.998 EQ01 18.0 0.1502 118 23.45 1.678 0.252 Vel = 6.682 0.0 2.650 Vel = 8.705 0.0 18.00 10.584 K Factor= 5.53 S002 18.00 1.049 1T 3.568 0.250 10.332 K Factor = 5.60 to 100 10.000 3.570 0.0 to EQ02 18.0 0.1500 3.820 0.573 Vel = 6.682 0.0 17.08 0.1362 10.000 1.362 18.00 126 17.98 1.049 10.905 K Factor= 5.45 S003 14.82 1.049 1T 3.568 0.250 7.000 K Factor = 5.60 to 100 127 3.570 0.0 EQ03 14.82 0.1047 5.151 Vel = 13.015 3.820 0.400 Vel = 5.502 0.0 7.000 16.042 K Factor @ node EQ06 to 14.82 0.0 0.0 7.400 K Factor= 5.45 S004 14.82 1.049 1 E 1.427 0.250 7.000 K Factor = 5.60 to 100 1.61 1T 1.428 0.0 18.362 EQ04 14.82 0.1049 100 1.678 0.176 Vel = 5.502 0.0 14.82 7.176 S005 16.65 1.049 1 E 1.427 0.250 8.840 to 100 1.428 C0.0 5 16.65 0.1299 1.678 0.218 0.0 16.65 9.058 K Factor = 5.53 K Factor = 5.60 Vel = 6.181 K Factor = 5.53 S006 15.45 1.049 1T 3.568 0.250 7.612 K Factor = 5.60 to 100 3.570 0.0 EQ06 15.45 0.1131 3.820 0.432 Vel = 5.735 0.0 15.45 8.044 K Factor= 5.45 129 23.45 1.049 1 E 1.427 5.830 17.540 K Factor = 5.60 to 100 IT 3.568 4.998 0.0 118 23.45 0.2447 10.828 2.650 Vel = 8.705 0.0 23.45 20.190 K Factor= 5.22 125 17.08 1.049 10.000 9.531 K Factor @ node EQ05 to 100 0.0 0.0 126 17.08 0.1362 10.000 1.362 Vel = 6.341 126 17.98 1.049 10.000 10.892 K Factor @ node EQ03 to 100 0.0 0.0 127 35.06 0.5151 10.000 5.151 Vel = 13.015 127 21.81 1.38 7.000 16.042 K Factor @ node EQ06 to 100 0.0 0.0 128 56.87 0.3314 7.000 2.320 Vel = 12.199 128 23.34 1.61 1T 5.710 1.870 18.362 K Factor @ node EQ03 to 100 5.712 0.0 119 80.21 0.2956 7.582 2.241 Vel = 12.641 0.0 80.21 20.603 K Factor = 17.67 121 17.09 1.049 10.000 9.542 K Factor @node EQ05 to 100 0.0 0.0 122 17.09 0.1363 10.000 1.363 Vel = 6.344 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard : Xcel Fire Protection Inc. Page 7 RIVERBEND DRY Date 031203 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. C. or Ftng's Pe Pv **'*""" Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 122 18.00 1.049 10.000 10.905 K Factor @ node EQ02 to 100 0.0 0.0 123 35.09 0.5159 10.000 5.159 Vel = 13.026 123 21.83 1.38 7.000 16.063 K Factor @ node EQ06 to 100 0.0 0.0 124 56.92 0.3320 7.000 2.324 Vel = 12.209 124 23.36 1.61 1T 5.710 1.870 18.388 K Factor @ node EQ03 to 100 5.712 0.0 105 80.28 0.2961 7.582 2.245 Vel = 12.652 0.0 80.28 20.633 K Factor= 17.67 120 24.73 1.049 IT, 3.568 1.830 19.499 K Factor = 5.60 to 100 3.570 0.0 106 24.73 0.2700 5.400 1.458 Vel = 9.180 0.0 24.73 20.957 K Factor = 5.40 113 16.87 1.049 10.000 9.303 K Factor @ node EQ04 to 100 0.0 0.0 114 16.87 0.1331 10.000 1.331 Vel = 6.263 114 17.76 1.049 10.000 10.634 K Factor @ node EQ03 to 100 0.0 0.0 115 34.63 0.5034 10.000 5.034 Vel = 12.856 115 21.56 1.38 7.000 15.669 K Factor @ node EQ03 to 100 0.0 0.0 116 56.19 0.3241 7.000 2.269 Vel = 12.0.53 116 23.07 1.61 1T 5.710 1.870 17.939 K Factor @ node EQ03 to 100 5.712 0.0 117 79.26 0.2891 7.582 2.192 Vel = 12.491 117 0.0 2.635 2.250 20.131 to 100 0.0 0.0 118 79.26 0.0262 2.250 0.059 Vel = 4.663 118 23.45 2.635 9.750 20.190 to 100 0.0 0.0 119 102.71 0.0424 9.750 0.413 Vel = 6.043 119 80.22 2.635 1 E 5.879 14.750 20.604 to 100 IT 11.758 17.644 0.0 107 182.93 0.1234 32.394 3.996 Vel = 10.763 0.0 182.93 24.600 K Factor= 36.88 109 18.75 1.049 10.000 11.482 K Factor @ node EQ05 to 100 0.0 0.0 110 18.75 0.1618 10.000 1.618 Vel = 6.960 110 19.72 1.049 10.000 13.099 K Factor @ node EQ02 to 100 0.0 0.0 111 38.47 0.6116 10.000 6.116 Vel = 14.281 111 23.90 1.38 10.000 19.216 K Factor @ node EQ02 to 100 0.0 0.0 112 62.37 0.3932 10.000 3.932 Vel = 13.378 112 0.0 1.61 IT 5.710 5.000 23.148 to 100 5.712 0.0 108 62.37 0.1856 10.712 1.988 Vel = 9.829 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 ,Final Calculations - Standard Xcel Fire Protection Inc. Page 8 RIVERBEND DRY Date 031203 Hyd. Qa Dia. Fitting Pipe Pt Pt Ct Qt "C" Pf/UL or Eqv. Ln. Ftng's Total Pe Pf Pv *'" *'" Notes **"* Pn 0.0 62.37 25.136 K Factor= 12.44 100 16.71 1.049 10.000 9.414 K Factor @ node EQ03 to 100 0.0 0.0 101 16.71 0.1308 10.000 1.308 Vel = 6.203 101 18.11 1.049 10.000 10.722 K Factor @ node EQ04 to 100 0.0 0.0 102 34.82 0.5086 10.000 5.086 Vel = 12.926 102 21.67 1.38 7.000 15.808 K Factor @ node EQ02 to 100 0.0 0.0 103 56.49 0.3274 7.000 2.292 Vel = 12.117 103 23.19 1.61 1T 5.710 1.870 18.100 K Factor @ node EQ02 to 100 5.712 0.0 104 79.68 0.2920 7.582 2.214 Vel = 12.557 104 0.0 2.635 12.000 20.314 to 100 0.0 0.0 105 79.68 0.0265 12.000 0.318 Vel = 4.688 105 80.28 2.635 3.370 20.632 to 100 0.0 0.0 106 159.96 0.0961 3.370 0.324 Vel = 9.411 106 24.73 2.635 1 E 5.879 11.370 20.957 t . 100 1T 11.758 17.644 0.0 184.69 0.1256 29.014 3.643 Vel = 10.866 6-771 182.93 3.26 3.370 24.600 to 100 0.0 0.0 108 367.62 0.1591 3.370 0.536 Vel = 14.130 108 62.36 3.26 78.000 25.136 to 100 0.0 0.0 200 429.98 0.2126 78.000 16.586 Vel = 16.527 200 0.0 4.26 1T 18.795 111.660 41.722 to 100 3E 9.397 47.007 0.0 DPV 429.98 0.0578 158.667 9.168 Vel = 9.679 DPV 0.01 4.260 1T 26.334 6.250 50.891 to 120 26.334 3.815 Fixed loss = 1 BOR 429.99 0.0412 32.584 1.344 Vel = 9.679 BOR 0.0 4.26 1E 13.167 11.000 56.050 to 120 13.167 4.000 Fixed loss = 4 TOU 429.99 0.0413 24.167 0.997 Vel = 9.679 TOU 0.0 6.16 1 E 20.084 50.000 61.046 to 140 20.084 0.866 HOSE 429.99 0.0052 70.084 0.361 Vel = 4.629 HOSE 250.00 6.16 50.000 62.273 Qa = 250 to 140 0.0 0.0 TEST 679.99 0.0120 50.000 0.601 Vel = 7.320 .0 679.99 62.874 K Factor= 85.76 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 AL _ _ _ Fire Protection by Computer Design Xcel Fire Protection Inc. 11A Industrial Way Salem Nh 03079 800-537-3331 Job Name RIVERBEND RESIDENTAL Building RIVERBEND HOUSING Location GREENE STREET, NORTH ANDOVER System 5 OF 5 Contract 2003-008 Data File RIVER.WX4 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Xcel Fire Protection Inc. Page 1 RIVERBEND RESIDENTAL A Date of Test - Date 031103 HYDRAULIC DESIGN INFORMATION SHEET T Time of Test - Name - RIVERBEND Date - 03/14/03 0 Location - GREENE STREET, NORTH ANDOVER 86 Building - RIVERBEND HOUSING System No. - 5 OF 5 R Residual (Psi) - Contractor - XCEL FIRE PROTECTION Contract No. - 2003-008 Well O Calculated By - XCEL FIRE PROTECTION Drawing No. - 5 OF 5 Construction: ( ) Combustible (X) Non -Combustible Ceiling Height VARIES 0 OCCUPANCY - SENIOR HOUSING S Type of Calculation: ( )NFPA 13 Residential (X)NFPA 13R ( )NFPA 13D Y Number of Sprinklers Flowing: ( )l ( )2 (X)4 ( ) S ( ) Other T ( )Spec ific`'Rul,ing4,: Made by Date Err: M ListedlFloiiva't'iS'tart\Po nt - 16 Gpm System Type ListedliP,res. at)Start, Rolnt - 14.5 Psi (X) Wet ( ) Dry D MAXIMUM LISTED -48P, G4' f 16 x 16 ( ) Deluge ( ) PreAction E Domestic ElowrA14 dded�`� - 0 Gpm Sprinkler or Nozzle S Additional°F1ow�Added"/� - 100 Gpm Make CENTRAL Model LFII CONC I ElevationatryHghestEOutlet - 51 6'Feet Size 1/2 K -Factor 9.2 G Note: Temperature Rating 155 N Calculation Gpm Required 168.50 Psi Required 61.815 At Test Summary C -Factor Used: Overhead 150 Underground 100 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 86 R Residual (Psi) - 62 Other Other Well O Flow (Gpm) - 1040 Proof Flow Gpm S Elevation - 0 P Location: GREENE STREET P L Source of Information: Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 MI U_ a� a ::3cz U '� Q � " O Q aw L � m W ca N > x 0 0 Q 2 Z E to t r r r a� _ O U C U O T 2 T w E m D1 O d a> CL a�aO�n.a v, ,n a? o�c� NICD OON (Q r r N � O O00 o � EU � �•� C U) (6 co r � C LL 6- O T TQ T� W fn fn " "(n 0 w N w rNN O OM (Dco ��022�fn N U O 0 o r 0 0 r N cq O r O < N r Z O J LL 0 0 0 r W CD O cn C� co 000o .. o a- LL o O-aoo v 3 'v, @ N N (n0'Q' O O i i i r N N N >UUU 7 V M N O O O O O O Co O O O r r r r r r O M r- O U') co N r 0 0 Q 2 Z E to t r r r a� _ O U C U O T 2 T w E m D1 O d a> CL o � EU � �•� � O T TQ T� W fn fn " "(n w N w rNN O OM (Dco ��022�fn N U N E 0 U Fittings Summary Xcel Fire Protection Inc. RIVERBEND RESIDENTAL Page 3 Date 031103 Fitting Legend Abbrev. Name A Generic Alarm Va B Generic Butterfly Valve C Roll Groove Coupling D Dry Pipe Valve E 90' Standard Elbow F 45' Elbow G Gate Valve H 45' Grvd-Vic Elbow I 90' Grvd-Vic Elbow J 90' Grvd-Vic Tee K Detector Check Valve L Long Turn Elbow M Medium Tum Elbow N PVC Standard Elbow O PVC Tee Branch P PVC 45' Elbow Q Flow Control Valve R PVC Coupling/Run Tee S Swing Check Valve T 90' Flow thru Tee U 45' Firelock Elbow V 90' Firelock Elbow W Wafer Check Valve X 90' Firelock Tee Y Mechanical Tee Z Flow Switch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 0 N Fittings Summary Xcel Fire Protection Inc. RIVERBEND RESIDENTAL Unadjusted Fittings Table �1/2 3 1.0 2.0 1.0 1.0 7.0 3.0 1.0 1.0 4.0 3.0 2.0 2.0 1.0 2.0 1.0 1.0 2.0 7.0 3.0 1.0 1.0 5.0 4.0 4.0 2.0 1 1/2 2 21/2 Page 4 Date 031103 1/2 4 5 6 8 10 7.7 21.5 16 17.0 20 24 17.0 27.0 7.0 10.0 12.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 21.0 9.5 17.0 1.0 28.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 1.0 1.0 2.0 2.0 3.0 3.0 3.0 4.0 12.0 1.0 1.0 1.0 1.0 2.0 1.0 1.5 2.0 2.0 3.0 3.0 3.5 3.5 2.0 3.0 4.0 3.5 6.0 5.0 8.0 7.0 4.5 6.0 8.0 8.5 10.8 13.0 17.0 16.0 4.5 5.0 6.5 8.5 10.0 14.0 20.0 14.0 2.0 2.0 2.0 3.0 4.0 5.0 5.0 6.0 2.0 3.0 3.0 4.0 5.0 6.0 6.0 8.0 7.0 8.0 9.0 11.0 12.0 13.0 36.0 5.0 6.0 8.0 10.0 12.0 15.0 1.0 2.0 2.0 2.0 3.0 4.0 27.0 30.0 34.0 40.0 10.0 18.0 16.0 29.0 22.0 35.0 1.0 1.0 1.0 1.0 2.0 2.0 5.0 7.0 9.0 11.0 14.0 16.0 19.0 22.0 5.0 6.0 8.0 10.0 12.0 15.0 17.0 20.0 25.0 30.0 35.0 1.8 2.2 2.6 81.0 3.4 101.0 121.0 4.2 3.5 4.3 5.0 6.8 8.5 10.0 13.0 10.3 8.5 10.8 13.0 16.0 5.0 6.0 8.0 10.5 12.5 15.5 22.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 5 6 8 10 12 14 16 18 20 24 17.0 27.0 29.0 9.0 10.0 12.0 19.0 21.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 47.0 12.0 14.0 18.0 22.0 27.0 35.0 40.0 45.0 50.0 61.0 5.0 7.0 9.0 11.0 13.0 17.0 19.0 21.0 24.0 28.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0 11.0 13.0 4.5 5.0 6.5 8.5 10.0 18.0 20.0 23.0 25.0 30.0 8.5 10.0 13.0 17.0 20.0 23.0 25.0 33.0 36.0 40.0 21.0 25.0 33.0 41.0 50.0 65.0 78.0 88.0 98.0 120.0 36.0 55.0 45.0 8.0 9.0 13.0 16.0 18.0 24.0 27.0 30.0 34.0 40.0 10.0 12.0 16.0 19.0 22.0 33.0 27.0 32.0 45.0 55.0 65.0 76.0 87.0 98.0 109.0 130.0 25.0 30.0 35.0 50.0 60.0 71.0 81.0 91.0 101.0 121.0 4.2 5.0 5.0 8.5 10.0 13.0 13.1 31.8 35.8 27.4 21.0 25.0 33.0 12.0 14.0 18.0 22.0 27.0 35.0 40.0 45.0 50.0 61.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD Xcel Fire Protection Inc. Page 5 RIVERBEND RESIDENTAL Date 031103 Node Elevation K -Fact Pt Pn Flow Density Area Press No. Actual Actual Rea. - D301 51.75 4.2 14.51 na 16.0 D302 51.75 4.2 14.51 na 16.0 16 51.75 K = K @ EQ01 14.73 na 16.0 17 51.75 K = K @ EQ02 15.32 na 16.17 18 51.75 16.06 na 14 51.75 K = K @ EQ01 20.66 na 18.95 15 51.75 21.13 na 8 51.75 26.32 na RSP 51.75 33.54 na RCV 51.75 34.73 na RLT 31.0 43.73 na 1 51.75 K = K @ EQ01 17.37 na 17.38 2 51.75 18.74 na 3 51.75 18.93 na 4 51.75 20.6 na 5 51.75 22.21 na LSP 51.75 34.02 na LCV 51.75 34.89 na LLT 31.0 43.89 na TOR 6.25 54.89 na BOR 2.0 56.83 na TOU 2.0 60.87 na HOSE 0.0 61.76 na 100.0 TEST 0.0 61.81 na The maximum velocity is 16:46 and it occurs in the pipe between nodes 3 and 4 .0500 100.00 14.51 .0500 100.00 14.51 M Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations -Standard Xcel Fire Protection Inc. Page 6 RIVERBEND RESIDENTAL Date 031103 Hyd. Qa Dia. Fitting Pipe Pt Pt I.C. or Ftng's Pe Pv Notes 0 Qt Pf/UL Eqv. Ln. Total Pf Pn D301 16.00 1.109 1E 3.962 1.000 14.510 K Factor = 4.20 to 16.00 150 3.962 0.0 K Factor @ node EQ01 EQ01 16.0 0.0435 4.962 0.216 Vel = 5.314 17 0.0 0.0434 13.582 0.590 Vel = 5.314 17 16.00 1.109 4.700 14.726 K Factor= 4.17 D302 16.00 1.109 1T 9.906 1.000 14.510 K Factor = 4.20 to 32.17 150 9.905 0.0 Vel = 10.685 EQ02 16.0 0.0435 10.905 0.474 Vel = 5.314 18 0.0 1.109 IT 9.906 8.200 16.060 to 16.00 1.109 IT 9.906 8.160 14.984 K Factor = 4.13 16 16.00 1.109 1 E 3.962 9.620 14.726 K Factor @ node EQ01 to 18.065 150 3.962 0.0 1.109 17 16.0 0.0434 13.582 0.590 Vel = 5.314 17 16.17 1.109 4.700 15.316 K Factor @ node EQ02 to 37.67 150 0.0 0.0 is 18 32.17 0.1583 4.700 0.744 Vel = 10.685 0.0521 1Z 4.000 22.820 1.189 Vel = 5.937 18 0.0 1.109 IT 9.906 8.200 16.060 to 150 9.905 0.0 3 32.17 0.1582 18.105 2.865 Vel = 10.685 120 0.0 8.987 RLT 0.0 0.0004 24.750 0.011 32.17 RLT 0.0 18.925 K Factor= 7.39 14 18.95 1.109 7.910 20.664 K Factor @ node EQ01 to 7E 150 0.0 0.0 �1 18.95 0.0594 7.910 0.470 Vel = 6.294 to 0.0 1.109 IT 9.906 8.160 21.135 to 0.0 150 9.905 0.0 5 18.95 0.0595 18.065 1.074 Vel = 6.294 Vel = 7.851 0.0 1.109 4.580 20.597 to 0.0 150 0.0 RSP 0.0 18.95 1B 0.0 22.209 K Factor = 4.02 8 37.67 1.4 2E 4.862 96.280 26.323 to 32.17 150 4.750 18.926 9.724 0.0 150 RSP 37.67 0.0681 49.55 0.3518 106.004 7.222 Vel = 7.851 0.0 1.109 4.580 20.597 to 150 0.0 RSP 0.0 1.61 1B 0.0 1.820 33.543 to 120 is 9.000 21.000 0.0 RCV 37.67 0.0521 1Z 4.000 22.820 1.189 Vel = 5.937 IT 8.000 RCV 0.0 4.26 24.750 34.732 to 120 0.0 8.987 RLT 37.67 0.0004 24.750 0.011 Vel = 0.848 RLT 0.0 4.26 IT 26.334 223.583 43.730 to 120 7E 13.167 118.504 0.0 LLT 37.67 0.0005 342.087 0.156 Vel = 0.848 0.0 37.67 43.886 K Factor = 5.69 1 17.38 1.109 1T 9.906 17.090 17.374 K Factor @ node EQ01 to 150 9.905 0.0 2 17.38 0.0507 26.995 1.368 Vel = 5.773 2 0.0 1.109 3.640 18.741 to 150 0.0 0.0 3 17.38 0.0505 3.640 0.184 Vel = 5.773 Computer Programs by Hydratec Inc. Route -1 11 Windham N.H. USA 03087 32.17 1.109 4.750 18.926 0 150 0.0 0.0 4 49.55 0.3518 4.750 1.671 Vel = 16.458 4 0.0 1.109 4.580 20.597 to 150 0.0 0.0 5 49.55 0.3520 4.580 1.612 Vel = 16.458 Computer Programs by Hydratec Inc. Route -1 11 Windham N.H. USA 03087 Final Calculations - Standard Xcel Fire Protection Inc. RIVERBEND RESIDENTAL Page 7 Date 031103 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv *"' *** Notes*f"` Point Qt Pf/UL Eqv. Ln. Total Pf Pn [`,�./j 5 18.95 1.4 1T 9.724 10.250 22.209 to to 150 120 1T 9.724 0.0 8 68.5 0.2060 68.5 0.0014 19.974 4.114 Vel = 14.277 8 -37.66 1.4 1T 6.436 101.840 26.323 to 9.333 120 to 6.436 0.0 LSP 30.84 0.0711 1.841 108.276 7.698 Vel = 6.428 LSP 0.0 1.61 1T 8.000 3.230 34.020 to 4.26 120 1B 0.0 21.000 0.0 LCV 30.84 0.0360 is 9.000 24.230 0.872 Vel = 4.860 Fixed loss = 4 TOU 68.5 1Z 4.000 30.334 LCV 0.0 4.26 24.750 34.892 to 120 0.0 8.987 LLT 30.84 0.0003 24.750 0.008 Vel = 0.694 LLT 37.66 4.26 6E 13.167 103.083 43.886 to 120 1T 26.334 105.336 10.719 TOR 68.5 0.0014 208.419 0.287 Vel = 1.542 TOR 0.0 4.26 IS 28.968 9.333 54.893 to 120 1 E 13.167 57.935 1.841 BOR 68.5 0.0014 1B 15.800 67.268 0.093 Vel = 1.542 BOR 0.0 4.26 1 E 13.167 4.000 56.826 to 120 1Z 13.167 26.334 4.000 Fixed loss = 4 TOU 68.5 0.0014 30.334 0.042 Vel = 1.542 TOU 0.0 6.16 1T 43.037 50.000 60.868 to 140 1 G 4.304 77.467 0.866 HOSE 68.5 0.0002 1F 10.042 127.467 0.022 Vel = 0.737 0 1 E 20.084 HOSE 100.00 6.16 1 G 4.304 50.000 61.756 Qa = 100.00 to 140 1 F 10.042 14.346 0.0 TEST 168.5 0.0009 64.346 0.059 Vel = 1.814 .0 168.50 61.815 K Factor= 21.43 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 O x X cel F ire P rotection, I nc. Fire Sprinkler Installation, Sales and Service Material Design Data Sheets 11 A Industrial Way, Unit 1, Salem, NH 03079 •1-603-890-3331 ' 1-800-537-3331 ' Fax: 1-603-898-9999 Submittal Data Sheet Schedule-10o/Schedule-40@ 0 Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-10/Schedule-40 sprinkler pipe you get UL listed and FM approved product. Although these products do not require separate approvals, Schedule-10/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10 (1'/a" - 8") pipe and Sch-40 (I" - 2'/z") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality Galvanized Pipe Schedule-10/Schedule-40 product can be "hot -dip" galvanized to meet FM. Superior Coating Our advanced formula mill coating offers a clean, durable surface. It is also paint - ready for custom color applications without special preparation. The internal surface of all black Fire Sprinkler pipe up to 4.5000" in diameter shall be coated with Allied Tube & Conduit Antibacterial Formula "ABF'. American Made Meets `Buy American" requirement and is available through distributors in the USA, Canada and Mexico. Specifications & Approvals Schedule-10/Schedule-40 pipe are in compliance with the following: ASTM A135 and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: Welded Outlets, Hydrostatic Pressure, Side Wall Rupture, Vibration Test. 4 Riverbend Housing Project: Stamp Here American Tube and Pipe was acquired by Allied Tube and Conduit on February 1, 1997. The engineered lightwall and standard wall family of products . although they have different names are the same in all respects with regard to strength, weight, bundle count, listings and approvals. For example, Dyna -Flow and Super Flo are the same product as are Dyna Thread and Super 40. XL is manufactured with Exterior galvanized coating. BLT is manufactured with Black lacquer coating. Xcel Fire Protection Sprinkler Contractor: 0 Xcel Fire Protection Engineer: Specification Reference: Design - Build Project Locations: Comments: S5-4 UL FM ULC Listed Approved Listed 03/19/03 Date: 13,13R, 14 System Type: NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ WI/Lift (21') WI/Lift (24') WI/Lift (25') In; mm In; mm Lbs/Ft; Kg/m Lbs/Ft; Kg/m Lift Lbs; Kg Lbs; Kg Lbs; Kg 1" 1.049 1.680 2.05 70 2,470 2,822 2,940 25 26.6 2.5 3.05 70 1,120 1,280 1,334 1'/a" 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 11/2" 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 2" 2.067 3.650 5.13 30 2,300 2,628 2,738 50 52.5 5.4 7.63 30 1,043 1,192 1,242 21/2' 2.469 5.790 7.86 19 2,310 2,640 2,750 65 62.7 8.6 11.73 19 1,048 1,197 1,247 NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ WKift (21') W111ift (24') Wt/Lift (25' In; mm In; mm Lbs/Ft; Kg1m Lbs/Ft, Kg/m Lift Lbs; Kg Lbs; Kg Lbs; Kg 1" 1.097 1.400 1.81 91 2,675 3,053 3,185 25 27.9 2.1 2.70 91 1,213 1,385 1,445 11/4° 1.442 1.810 2.52 61 2,319 2,664 2,760 32 36.6 -2.7 3.75 61 1,052 1,208 1,252 11/2' 1.682 2.080 3.04 61 2,664 3,045 3,172 40 42.7 3.1 4.52 61 1,208 1,381 1,439 2" 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 21/2" 2.635 3.530 5.89 30 2,224 2,542 2,648 65 66.9 5.3 8.77 30 1,009 1,153 1,201 3" 3.260 4.330 7.94 19 1,728 1,975 2,057 80 82.8 6.4 11.82 19 784 896 933 4" 4.260 5.610 11.78 _ 19 2,238 2,558 2,665 90 108.2 8.3 17.53 19 1,015 1,160 1,209 5" 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 6" 6.357 9.290 23.03 10 1,951 2,230 2,322 150 161.5 13.8 34.27 10 885 1,012 1,053 8" 8.249 16.490 40.15 7 2,424 2,770 2,885 200 209.5 24.5 59.75 7 1,100 1,256 1,309 Riverbend Housing Project: Stamp Here American Tube and Pipe was acquired by Allied Tube and Conduit on February 1, 1997. The engineered lightwall and standard wall family of products . although they have different names are the same in all respects with regard to strength, weight, bundle count, listings and approvals. For example, Dyna -Flow and Super Flo are the same product as are Dyna Thread and Super 40. XL is manufactured with Exterior galvanized coating. BLT is manufactured with Black lacquer coating. Xcel Fire Protection Sprinkler Contractor: 0 Xcel Fire Protection Engineer: Specification Reference: Design - Build Project Locations: Comments: S5-4 UL FM ULC Listed Approved Listed 03/19/03 Date: 13,13R, 14 System Type: r MALLEABLE IRON 90' ELLS CLASS 150 �i NPS Center to End A Outside Dia. of Band H (min) Take Out Dimension Length of Threads B (min) 1/8" 0.690 0.690 0.440 0.250 1/4" 0.810 0.840 0.435 0.320 3/8" 0.950 1.010 0.575 0.360 1/2" 1.1.20 1.200 0.620 1 0.430 3/4" 1.310 1.460 0.748 0.500 1" 1.500 1.770 0.813 0.580 1 1/4" 1.750 2.150 1.063 0.670 11/2" 1.940 2.430 1.253 0.700 2" 2.250 2.960 1.500 0.750 21/2" 2.270 3.590 1.333 0.920 3" 3.080 4.280 2.080 0.980 4" 3.790 5.400 2.665 1.080 FIGURE 47 MALLEABLE IRON REDUCING 900 ELLS CLASS 150 0 FIGURE 47 NPS Center to End X Center to End Z Outside Dia. of Band C min Outside Dia. of Band H min Length of Thread B min Length of Thread F min Take Out Take Out 1/4 x 1/8" 0.740 0.760 0.840 0.690 0.320 0.250 0.365 0.510 3/8 x 1/4" 0.880 0.900 1.010 0.840 0.360 0.320 0.505 0.385 1/2 x 3/8" 1.040 1.030 1.200 1.010 0.430 0.360 0.540 0.655 1/2 x 1/4" 0.970 0.980 1.200 0.840 0.430 0.320 0.470 0.605 3/4 x 1/2" 1.200 1.220- 1.460 1.200 0.500 0.430 0.638 0.720 3/4 x 3/8" 1.120 1.130 1.460 1.010 0.500 0.360 0.558 0.755 1 x 3/4" 1.370 1.450 1.770 1.460 0.580 0.500 0.683 0.888 1 x 1/2" 1.260 1.360 1.770 1.200 0.580 0.430 0.573 0.860 1 x 3/8" 1.180 1.270 1.770 1.010 0.580 0.360 0.492 0.895 1 1/4 x 1" 1.580 1.670 2.150 1.770 0.670 0.580 0.893 0.983 1 1/4 x 3/4" 1.450 1.620 2.150 1.460' 0.670 0.500 0.763 1.058 1 1/4 x 1/2" 1.340 1.530 2.150 1.200 0.670 0.430 0.653 1.030 1 1/2 x 1 1/4" 1.820 1.880 2.430 2.150 0.700 1 0.670 1.133 1.193 1 1/2 x 1" 1.650 1.800 2.430 1.770 0.700 0.580 0.963 1.113 1` /2 x 3/4" 1.520 1.750 2.430 1.460 0.700 0.500 0.833 1.188 j2 x 1/2" 1.410 1.660 2.430 1.200 0.700 0.430 0.723 1.160 -,,f 1 1/2 " 2.020 1 2.160 2.960 2.430 0.750 0.700 1.270 1.473 2 x 1 1/4" 1.900 2.100 2.960 2.150 0.750 0.670 1.150 1.413 2 x 1" 1.730 2.020 2.960 1.770 1 0.750 0.580 0.980 1.333 2 x 3/4" 1.600 1.970 2.960 1.460 0.750 0.500 0.850 1.408 2 x 1/2" 1.490 1.880 2.960 1.200 0.750 0.430 0.740 1.380 2 1/2 x 2" 1 2.390 2.600 3.590 2.960 0.920 0.750 1.453 1.850 2 1/2 x 1 1/2" 2.160 2.510 3.590' 2.430 0.920 0.700 1.223 1.823 2.520 2.890 4.280 1 2.960 0.980 0.750 1.520 2.140 MALLEABLE IRON STREET 45c' ELLS CLASS 150 1 W] NPS Center to End C Center to Male End K Take Out Female End Take Out Male End Length of Internal Thread B min Length of External Thread L min Max Port Dia. of Male End N Outside Dia. of Band H min 1/81, 0.690 0.800 0.440 0.550 0.250 0.260 0.200 0.690 3/8" 0.800 1.030 0.425 0.655 0.360 0.410 0.370 1.010 1/2" 0.880 1.150 0.380 0.650 0.430 0.530 0.510 1.200 3/4" 0.980 1.290 0.418 0.728 0.500 0.550 0.690 1.460 1 " 1.120 1.470 0.433 0.783 0.580 0.680 0.910 1.770 11/4" 1.290 1.710 0.603 1.023 0.670 0.710 1 1.190 2.150 11/2" 1.430 1.880 0.743 1.193 1 0.700 0.720 1.390 2.430 2" 1.680 2.220 0.930 1.470 0.750 0.760 79 1.0 2.960 MALLEABLE IRON TEES STRAIGHT CLASS 150 FIGURE 52 NPS Center to End A Length of Threads B min Take Out Outside Dia. of Band H min 1/8" 0.690 0.250 0.565 0.690 1/4"_ 1 0.810 0.320 0.435 0.840 3/8" 0.950 0.360 0.575 1.010 1/2" 1.120 0.430 0.620 1.200 3/4" 1.310 0.500 0.748 1.460 V. 1.500 0.580 0.813 1.770 1 1/4" 1.750 0.670 1 1.063 2.150 1 1/2" 1.940 0.700 1.253 1 2.430 2" 2.250 0.750 1.500 2.960 21/2" 2.700 0.920 1.763 3.590 3" 3.080 0.980 2.080 ' 4.280 4" 3.790 1.080 2.665 5.400 t B lei i L -H -A 47 61 MALLEABLE IRON REDUCING TEES CLASS 1 5 0 I I FIGURE 52 NPS Center to End X Center to End Y Center to End Z Length of Thread B Length of Thread B2 Length of Thread B3 Take Out Take Out Take Out Outside Dia. of Band H (min) Outside Dia. of Band H2 (min) Outside Dia. of Band H3 (min) 3/8 x 3/8 x 1/2" 1.030 1.030 1.040 0.360 0.360 0.430 0.655 0.655 0.540 1.010 1.010 1200 1/2 x 1/2 x 3/4" 1.220 1.220 1.200 0.430 0.430 0.500 0.720 0.720 0.638 1.200 1.200 1.460 1/2 x 1/2 x 3/8" 1 040 1.040 1.030 0.430 0.430 0.360 0.540 0.540 0.655 1.200 1.200 1.010 1/2 x 1/2 x 1/4" 0.970 0.970 0.980 0.430 0.430 0.320 0.470 0.470 0.605 1.200 1.200 0.840 1/2 x 3/8 x 1/2" 1.120 1.030 1.120 0.430 0.360 0.430 0.620 0.655 0.620 1.200 1.010 1.197 1/2 x 3/8 x 3/8" 1.040 0.950 1.030 0.430 0.360 0.360 0.540 0.575 0.655 1200 1.010 1.010 3/4 x 3/4 x 1" 1.450 1.450 1.370 0.500 0.5Q0 0.580 0.888 0.888 0.808 1.460 1.460 1.770 3/4 x 3/4 x 1 /2" 1.200 1.200 1.220 0.500 0.500 0.430 0.638 0.638 0.720 1.460 1.460 1.200 ABX 3/4 X 3/8" 1.120 1.120 1.130 0.500 0.500 0.360 0.558 0.558 0.755 1.460 1.460 1.010 ;i 1/2 X 3/4" 1.310 1.220 1.310 0.500 0.430 0.500 0.748 0.720 0.748 1.460 1.200 1.460 rX 1/2 X 1/2" 1200 1.120 1.220 0.500 0.430 0.430 0.638 0.620 0.720 1.460 1200 1.200 3/4 X 3/8 X 3/4" 1.310 1.130 1.310 0.500 0.360 0.500 0.935 0.755 0.935 1.460 1.010 1.460 1 X 1 X 1 1/4" 1.670 1.670 1.580 0.580 0.580 0.670 0.983 0.983 0.893 1.770 1.770 2.150 1 X 1 X 3/4" 1.370 1.370 1.450 0.580 0.580 0.500 0.683 0.683 0.888 1.770 1.770 1.460 1 X 1 X 112" 1.260 1.260 1.360 0.580 0.580 0.430 0.573 0.573 0.860 1.770 1.770 1.200 1 X 1 X 3/8" 1.180 1.180 1270 0.580 0.580 0.360 '0.492 0.492 0.895 1.770 1.770 1.010 1 X 3/4 X 1" 1.500 1.450 1.500 0.580 0.500 0.580 0.813 0.888 0.813 1.770 1.460 1.770 1 X 3/4 X 3/4" 1.370 1.310 1.450 0.580 0.500 0.500 0.683 0.748 0.888 1.770 1.460 1.460 1 X 3/4 X 1/2" 1.260 1.200 1.360 0.580 0.500 0.430 0.573 0.638 0.860 1.770 1.460 1.200 1 X 1/2 X 1" 1.500 1.360 1.500 0.580 0.430 0.580 0.813 0.860 0.813 1.770 1.200 1.770 1 X 1/2 X 3/4" 1.370 1.220 1.450 0.580 0.430 0.500 0.683 0.720 0.888 1.770 1.200 1.460 1 X 1/2 X 1/2" 1.26.0 1.120 1.360 0.580 0.430 0.430 0.573 0.620 0.860, 1.770 1.200 1.200 1 X 1/4 X 1" 1.500 1.200 1.500 0.580 0.320 0.580 0.813 0.825 0.813 1.770 0.840 1.770 1 X 1/8 X 1" 1.500 1.100 1.500 0.580 0 550 0.580 0.813 0.850 0.813 1.770 0.690 1.770 1 1/4 X 1 1/4 X 1" 1.580 1.580 1.670 0.670 0.670 0.580 0.893 0.893 0.983 2.150 2.150 1.770 1 1 /4 X 1 1 /4 X 3/4" 1.450 1.450 1.620 0.670 0.670 0.500 0.763 0.763 1.058 2.150 2.150 1.460 1 1/4 X 1 1/4 X 1/2" 1.340 1.340 1.530 0.670 0.670 0.430 0.653 1 0.653 1.030 2.150 2.150 1.200 1 1/4 X 1 X 1 1/4" 1.750 1.670 1.750 0.670 0.580 0.670 1.063 0.983 1.063 2.150 1 1.770 2.150 1 1/4 X 1 X 1" 1.580 1.500 1.670 0.670 0.580 0.580 0.893 0.813 0.983 2.150 1.770 1.770 1 1 /4 X 1 X 3/4" 1.450 1.370 1.620 0.670 0.580 0.500 0.763 0.683 1.058 2.150 1.770 1.460 1 1 /4 x 3/4 x 1 1 /4" 1.750 1.620 1.750 0.670 0.500 0.670 1.063 1.058 1.063 2.150 1.460 2.150 CONTINUED ON NEXT PAGE I IN An - LM MALLEABLE IRON REDUCING TEES I 7 n n n � r- J !- !"1 A I -T- NPS H denotes Heel Ell Center Center to End X Center to End Y Center to End Z Length of Thread B Length of Thread B2 Length of Thread B3 Take Out Take Out Take Out Outside Dia. of Bard H (min) Outside Dia. of Band H2 (min) Outside Dia. of Band H3 (min) 1 1/4 x 3/4 x 1" 1.580 1 1.450 1.670 0.670 1 0.500 0.580 0.893 1 0.888 0.983 2.150 1 1.460 1.770 1 1/4 x 3/4 x 3/4" 1.450 11310 1.620 0.670 0.500 0.500 0.763 0.748 1.058 2.150 1 1.460 1.460 1 1/4 x 1/2 x 1 1/4" H 1.750 1.530 1.750 0.670 0.430 0.670 1.063 1.030 1.063 2.150 1.200 2.150 1 1/2 x 1 1/2 x 1 1/4" 1.820 1.820 1.880 0.700 0.700 0.670 1.133 1.133 1.193 2.430 2.430 2.150 1 1/2 x 1 1/2 x 1" 1.650 1.650 1.800 0.700 0.700 0.580 0.963 0.963 1.113 2.430 2.430 1.770 1 1/2 x 1 1/2 x 3/4" 1.520 1.520 1.750 0.700 0.700 0.500 10.833 0.833 1 1.188 2.430 2.430 1.460 1 1/2 x 1 1/2 x 1/2" 1.410 1.410 1.660 0.700 0.700 0.430 10.723 0.723 1.160 2.430 2.430 1.200 1 1/2 x 1 1/4 x 1 1/2" 1.940 1.880 1.940 0.700 0.670 0.700 1.253 1.193 1.253 2.430 2.150 2.430 1 1/2 x 1 1/4 x 1 1/4" 1.820 1.750 1.880 0.700 0.670 0.670 1.133 1.063 1.193 2.430 2.150 2.150 1 1/2 x 1 1/4 x 1 " 1.650 1.580 1.800 0.700 0.670 0.580 0.963 0.893 1.113 2.430 2.150 1.770 1 1/2 x 1 1/4 x 3/4" 1.520 1.450 1.750 0.700 0.670 0.500 0.833 0.763 1.188 2.430 2.150 1.460 1 1/2 x 1 x 1 1/2" 1.940 1.800 1.940 0.700 0.580 0.700 1.253 1.113 1 1.253 2.430 1.770 2.430 1 1/2 x 1 x 1" 1.650 1.500 1:800 0.700 0.580 0.580 10.963 0.813 1 1.113 2.430 1.770 2.430 1 1/2 x 3/4 x 1 1/2" H 1.940 1.750 1.940 0.700 0.500 0.700 1.253 1.188 1.253 2.430 1.460 2.430 1 1/2 x 3/4 x 3/4" 1.550 1.350 1.770 0.700 0.500 0.500 0.863 0.788 1.208 2.430 1.460 1.460 1 1/2 x 1/2 x 1 1/2" H 1.940 1.660 1.940 0.700 0.430 0.700 1.253 1.160 1.253 2.430 1.200 2.430 2 x 2 x 1 1/2" 2.020 2.020 2.160 0.750 0.750 0.700 1.270 1.270 1.473 2.960 2.960 2.430 2 x 2 x 1 1/4" 1.900 1.900 2.100 0.750 0.750 0.670 1.150 1.150 1.413 2.960 2.960 2.150 2 x 2 x 1" 1.730 1.730 2.020 0.750 0.750 0.580 10.980 0.980 1.333 2.960 2.960 1.770 2 x 2 x 3/4" 1.600 1.600 1.970 0.750 0.750 0.500 0.850 0.850 1.408 2.960 1 2.960 1:460 2 x 2 x 1/2" 1.490 1.490 1.880 0.750 0.750 0.430 10.740 0.740 1.380 2.960 2.960 1.200 2 x 1 1%2 x 2" 2.250 2.160 2.250 0.750 0.700 0.750 1.500 1.473 1.500 2.960 2.430 2.960 2 x 1 1/2 x 1 1/2" 2.020 1.940 2.160 0.750 0.700 0.700 1.270 1.253 1.473 2.960 2.430 2.430 2 x 1 1/2 x 1 1/4" 1.900 1.820 2.100 0.750 0.700 0.670 1.150 1.133 1.413 2.960 2.430 2.150 2 x 1 112 x 1" 1.730 1.650 2.020 0.750 0.700 0.580 0.980 0.963 1 1.333 2.960 2.430 1.770 2 x 1 1/4 x 2" 2.250 2.100 2.250 0.750 0.670 0.750 1.500 1.413 1.500 2.960 2.150 2.960 2 x 1 1/4 x 1 1/4" 1.900 1.750 .2.100 0.750 0.670 0.670 1 1.150 1.063 1.413 2.960 2.150 2.150 2 x 1 x 2" H 2.250 2.020 2.250 0.750 0.580 0.750 1.500 1.333 1.500 2.960 1.770 2.960 2 x 1 x 1" 1.780 1.680 2.080 0.750 0.580 0.580 1.030 0.993 1.393 2.960 1.770, 1.770 2)(3/4 x 2" 2.250 1.970 2.250 0.750 0.500 0.750 1.500 1.408 1.500 2.960 1.460 2.960 2 x 1/2 x 2" 2.250 1.880 2.250 0.750 0.430 0.750 1.500 1.380 1.500 2.960 1.200 2.960 21/2 x 2 1/2 x 2" 2.390 2.390 2.600 0.920 .0.920 0.750 1.453. 1.453 1.850 3.590 3.590 2.960 3 x 3 x 2 1/2" 2.830 2.830 2.990 0.980 0.980 0.920 1.830 1.830 2.053 4.280 4.280 3.590 3 x 3 x 2" 2.520 2.520 2.890 0.980 1 0.980 0.750 1.520 1.520 2.140 4.280 4.280 2.960 3 x 3 x 1 1/2" 2.290 2.290 2.800 0.980 0.980 0.700 1.290 1.290 2.113 4.280 4.280 2.430 3 x 3 x 1 1/4"2.170 2.170 2.740 0.980 0.980 0.670 1.170 1.170 2.053 4.280 4.280 2.150 3 x 3 x 1" - 2.000 2.000 2.660 0.980 0.980 0.580 1.000 1.000 1.973 4.280 4.280 1-.770 3 x 2 x 2" 2.520 2.250 2.890 0.980 0.750 0.750 1.520 1.500 2.140 4.280 2.960 2.960 1*1 NJ 7 MALLEABLE IRON STREET TEE CLASS 1 50 14 B T A N FIGURE 64 ' MALLEABLE IRON PIPE CAPS CLASS 150 "\NPS .,� Center Center to Take Out Take Out Outside Length Length Maximum NPS To End Male End Female End Male End Band Dia. of Thread of External Port Dia. 0.970 A J 1.770 1.160 (min) (min) Thrd (min) Male End 0.670 1 112" 2.430 1.330 0.700 H B L N 3/4" 1.310 1.890 0.748 1.328 1.460 0.500 0.550 0.690 1" 1.500 2.140 0.813 1.453 1.770 0.580 0.680 1 0.910 0.530 1.750 2.450 1.063 -j-1.763 0.630 2.150 0.670 0.710 1.190 MALLEABLE IRON PIPE CAPS CLASS 150 "\NPS .,� Outside Diameter H min Overall Height P min Length of Threads B min 1/4" 0.840 0.630 0.320 3/8" 1.010 0.740 0.360 1/2" 1200. 0.870 0.430 3/4" 1.460 0.970 0.500 1" 1.770 1.160 0.580 11/4" 2.150 1.280 0.670 1 112" 2.430 1.330 0.700 2" 2.460 1.450 0.750 2 1/2" 3.590 1.700 0.920 3" 4.280 1.800 0.980 4" 5.400 2.080 1.080 STEEL 1/8" 0.560 0.530 0.250 1/4" 0.690 0.630 0.320 3/8" 0.840 0.740 0.360 P 4 -H --I FIGURE 49 MALLEABLE IRON WASTE NUTS CLASS 150 Manufactured to WARD Specifications 8 .-1 End to End Height SIZE O Y CiPIPE 1/2" 2.420 .340 /4" 2.650 .320 1" 2.990 .370 Manufactured to WARD Specifications 8 .-1 �O1 Z FIGURE 62 MALLEABLE IRON STRAIGHT COUPLING CLASS 15,0 NPS Length of Coupling W Outside Dia. of Band H min Length of Threads B min 1/8" 0.960 0.690 0.250 1/4" 1.060 0.840 0.320 3/8" 1.160 1.010 0.360 112" 1.340 1.200 0.430 3/4" 1.520 1.460 0.500 11. 1.670 1.770 0.580 1 1/4" 1.930 2.150 0.670 1 112" 2.150 2.430 0.700 2" 2.530 2.960 0.750 21/2" 2.880 3.590 0.920 3" 3.180 4.280 0.980 4" 3.690 5.400 1.080 F I G U R E MALLEABLE IRON REDUCING COUPLING CLASS 150 NPS Overall Length M Outside Diameter Large End H min Outside Diameter Small End H2 min Take Out Take Out Length of Threads Large B1 min Length of Threads Small B2 min 1/4 x 1/8" 1.000 0.840 0.690 0.465 0.440 0.320 0.250 3/8 x 1/4" 1.130 1.010 0.840 0.635 0.465 0.360 0.320 1/2 x 3/8" 1.250 1.200 1.010 0.700 0.635 0.430 0.360 1/2 x 1/4" 1.250 1.200 0.840 0.700 0.465 0.430 0.320 3/4 x 1/2" 1.440 1.460 1.200 0.898 0.700 0.500 0.430 3/4 x 3/8" 1.440 1.460 1.010 0.898 0.635 . 0.500 0.360 3/4 x 1/4" 1.440 1.460 0.840 0.898 0.465 0.500 0.320 1 x 3/4" 1.690 1.770 1.460 1.083 0.898 0.580 0.500 1 x 1/2" 1.690 1.770 1.200 1.083 1 0.700 0.580 0.430 1 x 3/8" 1.690 1.770 1.010 1.083 0.635 0.580 0.360 1 1/4 x 1" 2.060 2.150 1.770 1.463 1.083 0.670 0.580 1 1/4 x 3/4"' 2.060 2.150 1.460 1.463 0.898 0.670 0.500 1 1/4 x 1/2" 2.060 2.150 1.200 1.463 0.700 0.670 0.430 1 1/2 x 1 1/4" 2.310 2.430 2.150 1.743 1.463 0.700 0.670 1 1/2 x 1" 2.310 2.430 1.770 1.743 1 1.083 0.700 0.580 1 1/2 x 3/4" 2.310 2.430 1.460 1.743 0.898 0.700 0.500 1 1/2 x 1/2" 2.310 2.430 1.200 1.743 0.700 0.700 0.430 2 x 1 112" 2.810 2.960 2.430 2.210 1.743 0.750 0.700 2 x 1 1/4" 2.810 2.960 2.150 2.210 1.463 0.750 0.670 2 x 1 " 2.810 2.960 " 1.770 2.210 1.083 0.750 0.580 2 x 3/4" 2.810 2.960 1.460 2.210 1 0.898 0.750 0.500 2 x 1/2" 2.810 2.960 1.200 2.210 0.700 0.750 0.430 2 1/2 x 2" 3.250 3.590 2.960 2.653 2.210 0.920 0.750 2 1/2 x 1 1/4" 3.250 3.590 2.430 2.653 1.743 0.920 0.700 3 x 2 1/2" 3.690 4.280 3.590 3.280 2.653 0.980 0.920 3 x 2" 3.690 4.280 2.960 3.280 2.210 0.980 0.750 3 x 1 1/2" 3.690 4.280 2.430 3.280 1 1.743 0.980 0.700 3 x 1 1/4" 3.690 4.280 2.150 3.280 1.463 0.980 0.670 3 x 1" 3.690 4.280 1.770 3.280 1.083 0.980 0.580 4 x 3" 4.380 5.400 4.280 4.275 3.280 1.080 0.980 4 x 2" 4.380 5.400 2.960 4.275 2.210 1.080 0.750 FIGURE 53 101 9 tqCO Flow Tyco Fire Control Products ARE SPR/NKLER APE & F/TT/NGS SUBMITTAL SHEET TYCO ARE PRODOCTS 451 North Cannon Avenue Lansdale, Pennsylvania 19446 www.tyco-fire.com TECHNICAL SERVICES TES (800) 381-9312 • Fax: (800) 791-5500 E -mm techserv@tycofp.com No. 19-1.5 TD915 41.1.20 9/2001 ° B/azeMaster � A ARE SPR/NKLER APE & F/TT/NGS SUBMITTAL SHEET TYCO ARE PRODOCTS 451 North Cannon Avenue Lansdale, Pennsylvania 19446 www.tyco-fire.com TECHNICAL SERVICES TES (800) 381-9312 • Fax: (800) 791-5500 E -mm techserv@tycofp.com No. 19-1.5 TD915 41.1.20 9/2001 Introduction Tyco Fire Products (TFP) BlazeMaster® CPVC pipe and fittings are designed exclusively for use in wet pipe automatic fire sprinkler systems. They are made from a specially developed thermoplastic compound composed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art additives. TFP BlazeMaster® CPVC products are easier to install than traditional steel pipe systems, and at Technical Data the same time, they provide superior heat resistance and strength as compared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapters are available to connect CPVC pipe to metallic piping. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. Sizes: 3/4" - 3" Manufacture Source: U.S.A. Maximum Working Pressure: 175 psi Material: Approvals: UL, FM, CUL, NSF, Dade County, LPCB, Pipe: ASTM F442, SDR 13.5 MEA, and the City of Los Angeles Fittings: ASTM F438 (Sch. 40) and Note: See current TFP BlazeMaster Installation Instructions and ASTM F439 (Sch. 80) Technical Manual, for exact listingtapproval information Color: Orange Pipe Nom.Pipe Size Avg. O.D. Inches Avg. I.D. Inches Wt. Lbs./Ft. Wt. N=0 filled Pipe Lbs./Ft. R. of Pipe per Lift Wt. per LiR Lbs. 3/4' 1.050 0.874 0.17 0.43 7875 1413 11. 1.315 1.101 0.26 0.67 5040 1320 1'/4" 1.660 1.394 0.42 1.07 2835 1191 1'/3" 1.900 1.598 0.55 1.40 2205 1136 2" 2.375 2.003 0.86 2.20 1 1260 1 1063 2 '/3" 2.875 2.423 1.26 3.22 1 1215 1 1531 3" 3.500 2.952 1 1.87 4.79 1 720 1 1344 Fittings To_ T" 45° Elbow Part No. Size Sch. T/O Wt. 80050 3/4" 40 3/6" 0.08 lb. 80051 1 " 40 3/6" 0.11 Ib. 80052 11/4" 40 3/4" 0.20 lb. 80053 1'/z" 80, '/16" 0.31 lb. 80054 2" 80 3/4" 0.56lb. 80055 2'/2" 80 3/4" 0.89 lb. 80056 3" 80 1 " 1.19 Ib. Tee Part No. Size Sch. T/O Wt. 80000 3/4" 40 %" 0.11 lb. 80001 1" 40 3/4" 0.19 lb. 80002 11/4" 40 '/6" 0.26 Ib. 80003 1'/2" 80 1 " 0.51 Ib. 80004 2" 80 13/6" 0.90 lb. 80005 2'/2' 80 19/,s" 1 1.59 lb. 80006 3" 80 111/7"F2,41 Ib. Reducing 90° Elbow Part No. Size Sch. T/O Wt. Ib. --,-12 No.1 80032 1 " x 3/4" 40 11/,6" 73/16" 0.16 Reducing Cross art Size T/02 Wbt. Size Sch. 80025 No.1 '40 9/16" 80015 1 " x 3/4" 1 40 "/,6" "/16" 0.28 90° Elbow Part No. Size Sch. T/O Wt. 80025 3/4" '40 9/16" 0.09 Ib. 80026 1 " 40 3/4" 0.14 Ib. 80027 11/4" 40 7/6" 0.21 lb. 80028 1'/z" 80 1'/16" 0.40 lb. 80029 2" 80 1'/4" 0.79 lb. 80030 21h" 80 1'/3" 1.141b. 80031 3" 80 113/16" 1.821b. Cross Part No. Size Sch. T/O Wt. 80009 3/4" 40 9/,6" 0.13 Ib. 80010 1 " 40 15/16" 0.23 Ib. 80011 1'/4" 40 15/76" 0.34 lb. 80012 1'/2" 80 Vh6" 0.67 Ib. 80013 2" 80 Ph" 1.00 Ib. 80014 2'/2" 80 19/16" 1 .9 1 Ib. 80008 3" 80 173/16" 2.89 lb. 0 I It x Coupling T/O Cap Part No. Size Sch. T/O Wt. 80075 3/4" 40 1/8" 0.071b. 80076 1" 40 '/e" 0.111b. 80077 1'/4" 40 3/16" 0.121b. 80078 1'/z" 80 3/,6" 0.251b. 80079 2" 80 3/16" 0.381b. 80080 2'/3" 80 3/16' 0.671b. 80081 1 3" 80 3/16' 0.911b. T/O 4� Part No. Size Sch. T/O Wt. 80100 3/4' 40 6/16" 0.041b. 80101 1 " 40 IN' 0.06 Ib. 80102 11/4"1 40 1/3" 0.101b. 80103 11/2" 80 6/8" 0.201b. 80104 2" 80 6/8" 0.31 1b. 80105 21/2" 80 1/8" 0.58 Ib. 80106 3" 80 1 " 0.88 Ib. vo Grooved Coupling -------- --- - P,petoo. Adapter Part No. Size Sch. T/O Wt. Pipe OD 80160 11/4" x 1'/4" Grooved 40 2'/16" 0.78 Ib. 11/4" (1.660") 80161 1'/2" x 1'/2' Grooved 80 2'/16" 0.95 Ib. 1'/3" (1.900") 80162 2" x 2" Grooved 80 2'/16" 1.42 Ib. 2" (2.375") 80163 2'/2" x 21/2" Grooved 80 2'16 2.28 Ib. 2'/3" (2.875") 80164 3" x 3" Grooved 80 21/4" 3.00 Ib. 3" (3.500") 80168 3" x 76.1 mm Grooved 80 21h" 2.72 Ib. 76.1 mm (3.000") TIO Female Adapter Part No. Size Sch. T/O Wt. 80142 3/4" x 3/4" NPT 40 5/e" 0.41 Ib. 80145 1" x 1" NPT 40 3/4" 0.63 Ib. 80146 11/4" x 1'/4" NPT 40 '/e" 1.03 Ib. 80147 1Ih" x 1'/3" NPT 80 1" 1.42 Ib. 80148 2" x 2" NPT 80 13/a" 2.66 Ib. T/O MaleLO Adapter Part No. Size Sch. T/O Wt. 80157 3/4" x 3/4" NPT 40 16/16" 0.33 Ib. 80158 1 " x 1" NPT 40 13/8" I 0.56 Ib. T/O Reducing Coupling Part No. Size I Sch. T/O I Wt. 80220 11" x3/," 1 40 1 '/8" 1 0.08 Ib. Part No. �I T/O T/O Wt. 80200 Reducer 40 ..... . Bushing 80201 11/4" x 3/4" Part No. Size Sch. T/O Wt. 80200 1" x 3/4" 40 7/,6' 0.04 Ib. 80201 11/4" x 3/4" 40 7/16' 0.11 Ib. 80202 11/4" x 1" 40 6/16" 0.12 Ib. 80203 11/2" x 3/4" 80 IN' 0.16 Ib. 80204 11/2' x 1 " 80 'h" 0.14 Ib. 80205 11/3" x 1'/4" 80 3/6" 0.17 Ib. 80206 2" x 3/4" 80 3/4' 0.27 1b. 80207 2" x 1" 80 "/16" 0.26 Ib. 80208 2" x 11/4" 80 '/16" 0.24 Ib. 80209 2" x 1'/2" 80 7/,6" 0.19 Ib. 80215 21/2"x 1" 80 115/,6" 0.42 Ib. 80214 21/3" x 1'/4" 80 13/4" 0.45 Ib. 80213 21/2" x 11/3" 80 16/6" 0.46 Ib. 80211 21/3" x 2" 80 1'/,6" 0.29 Ib. 80210 3" x 2" 80 2 3/16" 0.72 Ib. 80212 3" x 2'/2" 80 115/16" 0.47 Ib. i _ I l Reducing Tee rro' ]TV Part No. Size Sch. 1 T/O 2 3 Wt. Ib. 80132 3/4" X 3/4" X 1 " 40 3/4" 3/4" 5/6' 0.14 80133 1 " x 3/4" x 3/4" 40 '/2' "/16" 3/4" 0.14 80134 1 " x 3/4" x 1 "' 40 6/6" 3/4" 3/4" 0.17 80260 11. x 1 " x 3/4" 40 3/4" 3/4' 11/16' 0.16 80135 1'/4" x 1" x 3/4" 40 '/16" 3/4' '6/,6" 0.21 80136 1'/4" x 1 " x 1 " 40 "/16" 3/4" 15/16" 0.22 80137 11/4" x 1" x 11/4" 40 73/16" 15/16" 13/16" 0.26 80261 11/4" x 11/4" x 3/4" 40 5/6" 6/8" '/a" 0.23 80262 11/4" x 11/4" x 1 " 40 3/4" 3/4" 1/8" 0.26 80138 11/4" x 1'/4" x 11/3" 80 1 " 1.1 1 " 0.43 80140 1'/3" x 1'/4" x 3/4" 80 1/3" 5/e" 1 " 0.36 80141 1'/x" x 1IN' x 1" 80 '/z" 5/e" 11/8" 0.38 80263 1'/3" x 11/2" x 3/4" 80 '/,6" '/16" 1" 0.36 80264 11/3" x 11./3" x 1 " 80 '/16" '/s" . 1 " 0.38 80275 1'/8" x 11/2" x 11/4" 80 1/8" '/6" 1" 0.45 80265 2" x 2" x 3/4" 80 3/4" 3/4" 13/6' 0:61 80266 2" x 2" x 1" 80 '/6" '/8" 13/6" 0.66 80274 2" x 2" x 11/4" 80 ill 1 " 13/6" 0.74 80267 2" x 2" x 1'/z" 80 1'/8" 1'/e" 13/6" 0.78 80271 21/z" x 21/2' x 1 " 80 1 "/,6' 111/, ' 1'/,6" 1.43 80272 21/z" x 2'/2" x 11/4" 80 1 11h." 1 "/16" 11/,6" 1.46 80273 21/3" x 21/3" x 1'/2" 80 1 "/,6" 1 11/,6" 1'/,6' 1.48 80276 21/3" x 2'/3" x 2" 80 1 1'/16" 1 "116° 1'/,6" 1.50 80270 3" x 3" x 1'/2" 80 13/4" 13/4" 113/16" 2.28 80268 3" x 3" x 2" 80 13/4" 13/4" 13/4" 2.25- 80269 3" x 3" x 21/3" 80 13/4" 13/4" 1 17 he" 2.44 r T/0 Sprinkler Head AdapteriM with Brass Threaded Insert Part No. Size Sch. T/O Wt. 80175E 3/4" x'h" NPT 80 '/+6" 0.201b. 80176E 1" x'/2" NPT 80 7/16 0.22 Ib. 80177WL 3/4" x'/2" NPT 40 '/+6" 0.16 Ib. 80179 1 x'/4" NPT 40 3/4" 0.43 Ib. 'S/+s' 1'/,6" 0.73 80256 11/4"x 1" x'h" NPT T/O Sprinkler Head Adapter _ ._._tea (Spigot) -'---'--- --- -'- with Brass Threaded Insert Part No. Size Sch. T/O Wt. 80177L 3/4" x'/2" NPT 40 1h" 0.16 Ib. 80178 1" x'/2" NPT 40 1/2" 0.20 Ib. T/O' Sprinkler Head Adapter 900 Elbow - } with Brass Threaded Insert T/O i I Part T/O I Wt. No. Size Sch. 1 2 Ib. 80199 3/4" x'/2' NPT 40 '/s" 15/+6" 0.20 80189 1 " x 'h" NPT 40 She' 13/,6" 0.26 Sprinkler Head Adapter Tee with Brass Threaded Insert Limited Warranty MeO T/0 Sprinkler Head Adapter with Brass Threaded Insert Part No. Size Sch. T/O Wt. 80175W 3/4" x'/8' NPT 40 '/+6" 0.19 Ib. 80176W 1" x'/2" NPT 40 1 7/+6" 0.18 Ib. Back -to -Back Cross with Brass Threaded Insert Part T/O Wt. No. Size Sch. 1 F2 Ib. 80462 1 " x 1 " x 1h" NPT x '/_" NPT 40 5/s" 1'/6" 0.46 80463 1 " x 1 " x '/z" N PT x '/2" NPT 40 5/s" 15/,6" 0.47 i l Back -to -Back Tee T'°' _ --4_ with Brass Threaded Insert f ' T/0' T/O' Part Size Sch. T/O Wt. No. 1 2 Ib. 80459 1" x'/z" NPT x'/2" NPT 40 "/,6" 15/,8' 0.48 80460 1" x 72" NPT x'/2" NPT 40 "/,6" 1'/s" 0.46 Part No Size Sch. 1 T/O 2 3 Wt. Ib. 80250 3/4" x %" x '/z" NPT 40 5/s" 5/s" 1 " 0.22 80251 1" x 1 " x 'h" NPT 40 '1/16" '716" 13/+6" 0.29 80249 1" x 1"x 1" NPT 40 15/+6" 'S/+s' 1'/,6" 0.73 80256 11/4"x 1" x'h" NPT 40 '/+6" '/+6" 1'/s" 0.30 80252 11/4" x 1'/4" x'/2" NPT 40 1/,6" '/,6" 1'/s" 0.31 80257 11/z" x 11/4" x 1h" NPT 80 1 1/,6" ' 5/9" 1'/,6" 0.43 80254 1'/3" x 1'/z" x'/2" NPT 80 'h6" '/18' 1'/,6" 0.46 80258 2" x 1'/2' x 1h" NPT 80 1/2" 5/s" 15/6" 0.56 80253 2" x 2" x'/s" NPT 1 80 '/z" 1/2" 15/8' 0.62 Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed,' maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCT'S LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIEDINCLUDING WARRANTIES OF MERCHANTABILITY.AND FITNESS FOR A PARTICULAR PURPOSE. tgCO/Flow Control/ Tyco Fire Products NO tqcoFre & Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Model DPV-1 Dry Pipe Valve, External Resetting 4 Inch (DN100), 250 psi (17,2 bar) GxG, FxG, orFxF General Description The 4 inch (DN 100), Model DPV-1 Dry Pipe Valve is a differential valve used to automatically control the flow of water into a dry. pipe fire protection sprinkler system upon operation of one or more automatic sprinklers. The DPV-1 also provides for actuation of fire alarms upon system operation. The Model DPV-1 features are as fol- lows: •External reset. • 250 psi (17,2 bar) pressure rating. 1 Unique offset single clapper design enabling a simple compact valve to minimize installation labor. Ductile iron construction to ensure a lightweight valve to minimize ship- ping cost. • A variety of inlet and outlet connec- tions. , • Compact, semi-preassembled and fully assembled, and easy to operate valve trim. • Simple reset procedure through the elimination of priming water.. Dry pipe sprinkler systems are used in unheated warehouses, parking ga- rages, store windows, attic spaces, loading docks, and other areas ex- posed to freezing temperatures, where water filled pipe cannot be utilized. When set for service, the dry pipe sprinkler system is pressurized with air (or nitrogen). The loss of pressure through an operated automatic sprin- kler in response to heat from a fire permits the DPV-1 Dry Pipe Valve to open and allow a flow of water into the sprinkler system piping. Table A estab- lishes the minimum required system air pressure that includes a safety fac- tor to help prevent false operations that occur due to water supply fluctuations. WARNING The Model DPV-1 Dry Pipe Valve de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the integrity of this device. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or manufac- turer should be contacted relative to any questions. Technical Data Approvals: UL and C -UL Listed. FM Approved. NYC under MEA 172-02-E. Dry Pipe Valve: The 4 inch (DN100), Model DPV-1 Dry Pipe Valves are for vertical installa- tions (flow going up), and they are rated for use at a maximum service pressure of 250 psi (17,2 bar). The Valve dimensions are shown in Figure 6. Flanged connections are available drilled per ANSI, ISO, AS, and JIS specifications (Ref. Table 13). The grooved outlet connections, as appli- cable, are cut in accordance with standard groove specifications for steel pipe. They are suitable for use with grooved end pipe couplings that are listed or approved for fire protec- tion system service. Available combi- nations of inlet and outlet connections are -detailed in the Ordering Procedure section. Threaded port connections of valves having flanges drilled to ANSI, AS, or JIS specifications are NPT threaded per ANSI Standard 131.20.1. Threaded port connections of valves having Page 1 of 12 MARCH, 2003 TFP1041 Page 2 of 12 6 7 CLAPPER ASSEMBLY 8 1 0-11 V12 13 RESET v 14 PLUNG ER �J PARTS 15,18 16 17 �// 1F 3 TFP1041 NO. DESCRIPTION QTY. REF. 1 Valve Body ....... 1 NR 2 Air and Water Seat ............ 1 NR 3 Handhole Cover ... 1 See (a) 4 Handhole Cover Gasket .......... 1 See (d) 5 1/2-13 UNC x 1" Hex Head Cap Screw ........... 6 CH 6 Clapper .......... 1 See (c) 7 Clapper Facing .... 1 See (c) or (d) 8 Clapper Facing Retaining Plate .... 1 See (c) 9 1/4-20 UNC x 1/2" Socket Head Cap Screw ........... 7 See (c) 10 Clapper Hinge Pin ............. 1 See (b) 11 Reset Knob ...... 1 See (e) 12 Reset Spring ..... 1 See (e) 13 Reset Bushing .... 1 See (e) 14 Reset Bushing O -Ring........... 1 See (d) or (e) 15 Reset Plunger O -Ring .......... 1 See (d) or (e) 16 Reset Plunger. 1 See (e) 17 Reset Latch Subassembly ..... 1 See (e) 18 Dow Corning FS3452 Flourosilicone Grease, 1.5 g ..... 1 See (d) or (e) NR: Not Replaceable CH: Common Hardware REPLACEMENT PARTS NO. DESCRIPTION P/N (a) Handhole Cover ...... 92-309-1-401 (b) Clapper Hinge Pin .... 92-309-1-402 (c) Clapper Assembly Includes Items: 6 through 9 .......... 92-309-1-403 (d) Repair Parts Kit Includes Items: 4, 7, 14, 15, 18 ....... 92-309-1-404 (e) Reset Plunger Parts Kit Includes Items: 11 through 18 ........ 92-309-1-405 FIGURE 1 4 INCH (DN100) MODEL DPV-1 DRY PIPE VALVE — ASSEMBLY — 0 EO 0 TFP1041 Maximum Water Supply Pressure, psi System Air Pressure Range, psi 20 10 60 15-23 80 20-28 100 25-33 120 30-38 145 35-43 165 40-48 185 45-53 205 50-58 225 55-63 250 60-68 TABLE A SYSTEM AIR PRESSURE REQUIREMENTS flanges drilled to ISO are available either threaded per ISO 7/1 or NPT threaded per ANSI Standard 131.20.1. Valves with NPT threaded ports will readily accept the trim arrangement detailed in Figure 4. NOTE For a system working pressure in ex- cess of 175 psi (12,1 bar) up to 250 psi (17,2 bar), the flanged connection(s) of the DPV-1 must be fitted with flange to groove adapters. The flange to groove adapters will permit a simple transition between the 250 psi (17,2 bar) rated DPV-1 and piping compo- nents of a higher pressure rating than Class 125 flanges and flanged fittings, which are limited to 175 psi (12,1 bar). The flange to groove adapters must be selected based on their having a maxi- mum working pressure for the antici- pated conditions. The use of a Central Grooved Piping Product Figure 71 Flange Adapter is recommended. Components of the 4 Inch (DN100) DPV-1 Valve are shown in Figure 1. The Body and Handhole Cover are ductile iron. The Handhole Cover Gas- ket is neoprene, and the Clapper Fac- ing is EPDM. The Air/Water Seat Ring is brass, the Clapper is copper, and both the Clapper Retaining Plate and Latch are bronze. The Hinge Pin is aluminum bronze, and the fasteners for the Handhole .Cover are carbon steel. Page 3 of 12 • WA OCOEE ■■■■■■■■■■■■■n�■�■■■■■rri of �SO ' ■■■■■■■Soosnu1�■■■■■■■■A SO ■■■■■1111111111■■■■■/�■■■■ ■■■■IIIIIilllll■■■■��■1■■ ■■■�IIIIIIIIIII■■■■I■t1■■ ' ■■■■■■■■■■■1111■//■■■■■■�■ .. ■■■■11111111111/I■■■■■■1■■ � �.� � ■■■IIIIIIIIIIII,�■■■■■■■■■ ' ■■■■1111111111■■■■■■11■■ � • off ■■■■■■■■■II■■�■■■■■■■■�■ • •.• - � ■■■■■■■,/,/111111■■■■■■■■■■ • . • • ■■■■II/11111111■■■■■■■1■■ • . .�...',■■■■■■■.. 21 2121 M... 1112011 .ti..■ ■■■■■■■■■■ aceta■ ■■ ■■rata ■■t■a►I■■■■■■■■■■aaalal■a a■a■a / .�../■■■■■■■■■■aaai■t■aa■a■a t■.I,■■■■■■■■■■■aa�al ■a ■■ala is .61 • • • Valve Trim: Installation dimensions are given in Figure 6, and the Valve Trim is illus- trated in Figures 4 and 5. The Valve Trim forms a part of the laboratory list- ings and approval of the DPV-1 Valve and is necessary for the proper opera- tion of the DPV-1 Valve. Each package of trim includes the following items: • Water Supply Pressure Gauge • System Air Pressure Gauge • Air Supply Connections • Main Drain Valve • Low Body Drain Valve • Alarm Test Valve • Automatic Drain Valve • Drip Funnel • Connections For Optional Quick Opening Device (Accelerator) NOTE When the system pressure is greater than 175 psi (12,1 bar), provision is to be made to replace the standard order 300 psi (20,7 bar) Water Pressure gauge, shown in Figure 4, with a sepa- rately ordered 600 psi (41,4 bar) Water Pressure Gauge. Air Supply: Table A shows the system air pressure requirements as a function of the water supply pressure. The air (or nitrogen) pressure in the sprinkler system is rec- ommended to be automatically main- tained by using one of the following Page 4 of 12 TFP1041 PORT ........ AIR PRESSURE WATER SUPPLY WATERFLOW SHUT OFF SHUT OFF TO SYSTEM FIGURE 3E TO SYSTEM RESET POSITION QCLAPPER CLAPPER 1" NPT ASSEMBLY ASSEMBLY AIR SUPPLY IN SET FULLY OPEN PORT POSITION 01 - - CLAPPER LATCH NPT PIVOTS TO ALLOW ° W WATER '� '1 CLAPPER ASSEMBLY SUPPLY TO FULLY OPEN PRESSURE 3/4° NPT ALARM --r-_T-- & ALARM PORT OPEN TO TEST PORT - ATMOSPHERE - 02 03 ALARM PORT WATERFLOW CLAPPER TO ALARM ASSEMBLY FROM FROM WATER SUPPLY AIR WATER SUPPLY SEAT FIGURE 3A FIGURE 3C SET POSITION WATER OPERATED POSITION SEAT ALARM 03 PORT DRAIN FROM DRAIN FROM SYSTEM SYSTEM VALVE q.INTERMEDIATE COMPLETE �( WATERWAY CHAMBER PUSH HERE V FIGURE 3B TO RESET SET POSITION VALVE INTERMEDIATE RESET. CHAMBER KNOB CLAPPER ASSEMBLY LATCHED RESET OPEN ASSEMBLY CLAPPER LATCH -- ° CLAPPER PIVOTS TO " LATCH UNLATCH CLAPPER ASSEMBLY 04 2' NPT 3/4' NPT 05 MAIN DRAIN CLAPPER LOW BODY PORT ASSEMBLY ASASSERTED DRAIN PORT ........ WATER SUPPLY WATER SUPPLY SHUT OFF SHUT OFF FIGURE 3D FIGURE 3E DRAIN POSITION RESET POSITION FIGURE 3 41NCH (DN100) MODEL DPV-1 DRY PIPE VALVE — SET AND OPEN POSITIONS — 101 C7 101 TFP1041 pressure maintenance devices, as ap- propriate: • Model AMD -1 Air Maintenance De- vice (pressure reducing type). • Model AMD -2 Air Maintenance De- vice (compressor control type). • Model AMD -3 Nitrogen Mainte- nance Device (high pressure reduc- ing type). The Pressure Relief Valve (Item 4 - Fig. 4) is factory set to relieve at a pres- sure of approximately 45 psi (3,1 bar). If the normal system air pressure is less than or exceeds 40 psi (2,8 bar), then the pressure Relief Valve must be reset to relieve at a pressure that is in accordance with the Authority Having Jurisdiction. Quick Opening Device: As an option, the Model DPV-1 Dry Pipe Valve may be equipped with the Model QRS Electronic Dry Pipe Valve Accelerator as detailed in Technical Data Sheet TFP1100 or the Model ACC -1 Mechanical Dry Pipe Valve Ac- celerator as detailed in Technical Data Sheet TFP1112. The QRS or the ACC -1 is used to re- duce the time to valve actuation fol- lowing the operation of one or more automatic sprinklers. In some cases the use of a quick opening device such as the QRS or the ACC -1 may be re- quired to meet the requirements of the National Fire Protection Association for systems having a capacity greater than 500 gallons (1890 litres). Patents: Features of the Model DPV-1 Dry Pipe Valve are patent pending. Operating Principles The Model DPV-1 Dry Pipe Valve is a differential type valve that utilizes a substantially lower system (air or nitro- gen) pressure than the supply (water) pressure, to maintain the set position shown in Figure 3A. The differential nature of the DPV-1 is based on the area difference between the air seat and the water seat in combination with the ratio of the radial difference from the Hinge Pin to the center of the Water Seat and the Hinge Pin to the center of the Air Seat. The difference is such that 1 psi (0,07 bar) of system air pres- sure can hold approximately 5.5 psi (0,38 bar) of water supply pressure. Table A establishes the minimum re- quired system air pressure that in- cludes a safety factor to help prevent false operations that occur due to water supply fluctuations. The Intermediate Chamber of the DPV-1 is formed by the area between the Air Seat and Water Seat as shown in Figure 3B. The Intermediate Cham- ber normally remains at atmospheric pressure through the Alarm Port con- nection and the valve trim to the nor- mally open Automatic Drain Valve (Item 6, Fig. 4). Having the Intermedi- ate Chamber, Figure 313, open to at- mosphere is critical to the DPV-1 Valve remaining set, otherwise the full result- ing pressure of the system air pressure on top of the Clapper Assembly cannot be realized. For example, if the sys- tem air pressure is 25 psi (1,7 bar) and there was 15 psi (1,0 bar) pressure trapped in the Intermediate Chamber, the resulting pressure across the top of the Clapper would only be 10 psi (0,7 bar). This pressure would be insuf- ficient to hold the Clapper Assembly closed against a water supply pres- sure of 100 psi (6,9 bar). It is for this reason that the plunger of the Auto- matic Drain Valve must be depressed during several of the resetting steps, as well as during inspections, making certain that the Automatic Drain Valve is open. When one or more automatic sprin- klers operate in response to a fire, air pressure within the system piping is relieved through the open sprinklers. When the air pressure is sufficiently reduced, the water pressure over- comes the differential holding the Clapper Assembly closed and the Clapper Assembly swings clear of the water seat, as shown in Figure 3C, This action permits water flow into the system piping and subsequently to be discharged from any open sprinklers. Page 5 of 12 Also, with the Clapper Assembly open, the intermediate chamber is pressur- ized and water flows through the alarm port (Ref. Figure 36) at the rear of the DPV-1 Valve to actuate system water flow alarms. The flow from the alarm port is also sufficient to close the oth- erwise normally open Automatic Drain Valve (Ref. Figure 4 or 5). After a valve actuation and upon sub- sequent closing of a system main con- trol valve to stop water flow, the Clap- per Assembly will latch open as shown in Figure 3D. Latching open of the DPV-1 will permit complete draining of the system (including any loose scale) through the main drain port. During the valve resetting procedure and after the system is completely drained, the external reset knob can be easily depressed to externally un- latch the Clapper Assembly as shown in Figure 3E. As such, the Clapper Assembly is returned to its normal set position to facilitate setting of the dry pipe sprinkler system, without having to remove the Handhole Cover. Installation NOTES Proper operation of the Model DPV-1 Dry Pipe Valve depends upon its trim being installed in accordance with the instructions given in this Technical Data Sheet. Failure to follow the ap- propriate trim diagram may prevent the DPV-1 Valve from functioning properly, as well as void listings, ap- provals, and the manufacturer's war- ranties. Failure to latch open the Clapper As- sembly prior to a system hydrostatic test may result in damage to the Clap- per Assembly. The DPV-1 Valve must be installed in a readily visible and accessible loca- tion. The DPV-1 Valve and associated trim must be maintained ata minimum tem- perature of 40°F/4°C. Heat tracing of the DPV-1 Valve or its associated trim is not permitted. Heat tracing can result in the formation of hardened mineral deposits that are ca- pable of preventing proper operation. The Model DPV-1 Dry Pipe Valve is to be installed in accordance with the fol- lowing criteria: Step 1. All nipples, fittings, and de- vices must be clean and free of scale and burrs before installation. Use pipe Page 6 of 12 I 1 _9 4 5 34 9 29 SLOPE DOWN LOCATION 19 FOR OPTIONAL ELECTRICALLY SUPERVISED N.O. ALARM CONTROL 41 VALVE (BVS-3/4") 24- 33 25 33 15 16 (GREEN O TINT) 28 6 34® 27 18 34 094 34 _% 8 6 / 40, ''tilt43 fiL G I \ 42 31 9 7 38 02 37 2 22 20 28 3 35 32 17 NO. DESCRIPTION QTY. P/N 1 250 psi/ 1750 kPa 3/32" Vent Air Pressure Fitting ........... Gauge ........... 1 92-343-1-012 2 300 psi/ 2000 kPa Water Pressure 24' Long ......... 1 Gauge ........... 1 92-343-1-005 3 1/4' Gauge Test CH 18 Valve ............ 2 46-005-1-002 4 1/4" Pressure 3/4" Plug ......... 1 Relief Valve....... 1 92-343-1-020 5 1/2" Angle Valve ... 1 46-048-1-004 6 Model AD -1 7 CH Automatic Bushing .........1 1 Drain Valve ....... 1 52-793-2-004 7 1/2" Ball Valve .... 1 46-050-1-004 8 1/2" Swing 1 CH Check Valve ...... 1 46-049-1-004 9 3/4" Angle Valve ... 1 46-048-1-005 10 3/4" Swing CH 26 Check Valve ...... 1 46-049-1-005 11 2" Angle Valve .... 1 46-048-1-009 12 Drip Funnel 28 1/2" x 1/4" x 1/2" Connector ........ 1 92-211-1-005 13 Drip Funnel 2 CH Bracket .......... 1 92-211-1-003 14 Drip Funnel ....... 1 92-343-1-007 NO. DESCRIPTION QTY. P/N 15 3/32" Vent Fitting ........... 1 92-032-1-002 16 1/4" Tube, 24' Long ......... 1 CH - 17 1/4" Plug ......... 2 CH 18 1/2" Plug ......... 2 CH 19 3/4" Plug ......... 1 CH 20 1" Plug .......... 1 CH 21 1/2" x 1/4" Reducing 7 CH 35 Bushing .........1 1 CH 22 1/2" Union ........ 1 CH 23 3/4" Union ........ 1 CH 24 1/2" 90" Elbow .... 1 CH 25 1/2" 45° Elbow .... 1 CH 26 1/2" Cross ........ 1 CH 27 1/2" Tee ......... 2 CH 28 1/2" x 1/4" x 1/2" 2 CH 40 Reducing Tee ..... 2 CH 29 1/2" x 1/2" x 1/4" 2 CH 41 Reducing Tee ....: 1 CH TFP1041 NOTES: 1. SEE FIGURE 3 FOR VALVE PORT IDENTIFICATION. 2. ROUTE 1/4" TUBING, ITEM 16, TO DRIP FUNNEL, ITEM 14. 3. SLOPE 3/4" ANGLE VALVE, 12 ITEM 9, DOWN TOWARD BACK OF VALVE TO FACILITATE SUFFICIENT LOW BODY DRAINAGE. 13 11 �\ 14 44 4 INCH (DN100) MODEL DPV-1 DRY PIPE VALVE NO. DESCRIPTION QTY. P/N 30 3/4" x 1/2" x 3/4" Reducing Tee ..... 3 CH 31 1"x1"x1/2" Reducing Tee ..... 1 CH 32 1/4"x 3" Nipple .... 2 CH 33 1/2" x Close Nipple ........... 2 CH 34 1/2'x 1-1/2" Nipple ........... 7 CH 35 1/2"x 2" Nipple .... 1 CH 36 1/2" x 2-1/2" Nipple ........... 1 CH 37 1/2" x 3" Nipple .... 1 CH 38 112" x 3-1/2" Nipple ........... 1 CH 39 3/4"x Close Nipple ........... 2 CH 40 3/4" x 1-1/2" Nipple ........... 2 CH 41 3/4" x 2" Nipple .... 1 CH 42 3/4" x 3" Nipple .... 1 CH 43 1" x 4" Nipple ..... 1 CH 44 2" x 4-1/2" Nipple ........... 1 CH All Fittings and Nipples are Galvanized CH: Common Hardware FIGURE 4 4 INCH (DN100) MODEL DPV-1 DRY PIPE VALVES — EXPLODED VIEW OF VALVE TRIM — 0 TFP1041 Page 7of12 1/2 INCH NPT AIR SUPPLY CONNECTION CONTROL VALVE 1 FOR OPTIONAL (NORMALLY ACCELERATOR OPEN) 1/2 INCH NPT MAIN CONNECTION SYSTEM DRAIN VALVE AUTOMATIC FOR OPTIONAL AIR SUPPLY _-.� 1/2 INCH NPT NORMALLY C� CONNECTION DRAIN VALVE AIR PRESSURE PRESSURE CLOSED) FOR WATERFLOW 1 SWITCH GAUGE SLOPE B PRESSUREALARM D DOWN SWITCH o 0 O o 3/4 INCH NPT o 0 CONNECTION 0 0 FOR WATER A MOTOR ALARM / 03 � 0 2 INCH NPT 1/2 INCH NPT L% I 01 CONNECTION CONNECTION I �j I TO DRAIN FOR SYSTEM 1 AIR SUPPLY C 0 4 INCH (DN100) ALARM Ok 02 MODELDPV-1 TEST VALVE v DRY PIPE VALVE (NORMALLY I 1 INCH NPT NOTES: CLOSED) 314 B CONNECTION 1. INSTALL TRIM ASSEMBLIES IN SYSTEM INCH NPT FOR LOCAL ALPHABETICAL ORDER. WATER SUPPLY CONNECTION SPRINKLER 2 SEE FIGURE 3 FOR VALVE PORT PRESSURE TO DRAIN IDENTIFICATION. GAUGE LOW BODY DRIP DRAIN VALVE 3. ROUTE 1/4" TUBING TO DRIP FUNNEL. FUNNEL 1.1/4 INCH NPT (NORMALLY 4. SLOPE ASSEMBLY B DOWN TOWARD CONNECTION CLOSED) BACK OF VALVE TO FACILITATE T DRAIN S FFI IENT L WB DY DRAINA E. FIGURE 5 4 INCH (DN100) MODEL DPV-1 DRY PIPE VALVES —ASSEMBLY PROCEDURE FOR VALVE TRIM — Dim. A Bolt Circle (8 Holes) p �'1 � Dim. B Bolt Hole Diameter Flange Drilling Specification Nominal Dimensions, Inches (mm) A B ANSI 816.1 (Class 125) 7.50 190,5 0.75 19,0 AS 2129 (Table E) 7.00 178,0 0.71 18,0 ISO 2084 (PN 16) * 7.09 180,0 0.71 18,0 JIS B 2210 (1 OK) 6.89 175,0 0.75 19,0 * Same drilling as for BS 4504 Section 3.2 (PN 16) and DIN 2532 PN16 . TABLE B — DIMENSIONAL SPECIFICATIONS FOR SELECTION OF FLANGE DRILLING Page 8 of 12 thread sealant sparingly on male pipe threads only. Step 2. The DPV-1 Valve must be trimmed in accordance with Figures 4 or 5, as applicable. If the DPV-1 is to be equipped with a Dry Pipe Valve Accelerator, refer to the Technical Data Sheet TFP1100 for the Model QRS Electronic Dry Pipe Valve Accelerator or TFP1112 for the Model ACC -1 Me- chanical Dry Pipe Valve Accelerator. Step 3. Care must be taken to make sure that check valves, strainers, globe valves, etc. are installed with the flow arrows in the proper direction. Step 4. Drain tubing to the drip funnel must be installed with smooth bends that will not restrict flow. Step 5. The main drain and drip funnel drain may be interconnected provided a check valve is located at least 12 inches (300 mm) below the drip funnel. The Low Body Drain Valve (Item 9 - Fig. 4) may be piped so as to discharge into the Drip Funnel or to a separate drain. Step 6. Suitable provision must be made for disposal of drain water. Drainage water must be directed such that it will not cause accidental dam- age to property or danger to persons. Step 7. Unused pressure alarm switch and/or water motor alarm connections must be plugged. Step 8. The Pressure Relief Valve pro- vided with the Valve Trim is factory set to relieve at a pressure of approxi- mately 45 psi (3,1 bar), which can typi- cally be used for a maximum normal system air pressure of 40 psi (2,8 bar). The Pressure Relief Valve may be re- set to a lower or higher pressure; how- ever, it must be be reset to relieve at a pressure which is in accordance with the requirements of the Authority Hav- ing Jurisdiction. To reset the Pressure Relief Valve, first loosen the jam nut and then adjust the cap accordingly — clockwise for a higher pressure setting or counter- clockwise for a lower pressure setting. After verifying the desired pressure setting, tighten the jam nut. Step 9. Installation of an Air Mainte- nance Device, as described in the Technical Data Section, is recom- mended. Step 10. An Inspector's Test Connec- tion as required By NFPA 13 must be provided on the system piping at the most remote location from the Model DPV-1 Valve. Step 11. Conduit and electrical con- nections are to be made in accordance with the requirements of the authority having jurisdiction and/or the National Electric Code. Step 12. Before a system hydrostatic test is performed in accordance with NFPA 13 system acceptance test re- quirements, the Clapper Assembly is to be manually latched open (Ref. Fig. 3D); the Automatic Drain Valve (Item 6, Fig. 4) is to be temporarily replaced with a 1/2 inch NPT plug, the 3/32 inch Vent Fitting (Item 15, Fig. 4) is to be temporarily replaced with a 1/4 inch NPT plug, and the Handhole Cover Bolts are to be tightened using a cross - draw sequence. Valve Setting Procedure Steps 1 through 12 are to be per- formed when initially setting the Model DPV-1 Dry Pipe Valve; after an opera- tional test of the fire protection system; or, after system operation due to a fire. Step 1. Close the Main Control Valve, and close the Air Supply Control Valve (Fig. 5). If the DPV-1 is equipped with a Dry Pipe Valve Accelerator, remove the Dry Pipe Valve Accelerator from service in accordance with its Techni- cal Data Sheet (Refer to TFP1100 for the QRS or TFP1112 for the ACC -1). Step 2. Open the Main Drain Valve (Fig. 5) and all auxiliary drains in the system. Close the auxiliary drain valves after water ceases to discharge. Leave the Main Drain Valve open. Step 3. Depress the plunger of the Automatic Drain Valve (Fig. 5) to verify that it is open and that the DPV-1 Valve is completely drained. Step 4. Open the Optional Alarm Con- trol Valve (Fig. 4), as applicable, if it was closed to silence local alarms. Step 5. As necessary, replace all sprinklers that have operated. Re- placement sprinklers must be of the same type and temperature rating as those which have operated. NOTE In order to prevent the possibility of a subsequent operation of an over- heated solder type sprinkler, any sol- der type sprinklers which were possi- bly exposed to a temperature greater than their maximum rated ambient must be replaced. Step 6. Push down on the Reset Knob (Fig. 3E) to allow the Clapper Assem- bly to reseat. Step 7. Pressurize the system with air (or nitrogen) to 10 psi (0,7 bar), and then individually open all auxiliary drain valves in the system piping to TFP1O41 drain any remaining water in trapped sections. Close each drain valve as soon as water ceases to discharge. Also partially open the Low Body Drain Valve (Fig. 5) to assure that the riser is completely drained. Close the Low Body Drain Valve as soon as water ceases to discharge. Step 8. Refer to Table A and then re- store the system to the normal system air pressure as necessary to hold the DPV-1 Valve closed. Step 9. Depress the plunger on the Automatic Drain Valve to make sure it is open and that there is no air dis- charging. The absence of air discharging from the Automatic Drain Valve is an indica- tion of a properly set air seat within the DPV-1 Valve. If air is discharging, refer to the -Care and Maintenance section under Automatic Drain Valve Inspec- tion to determine/correct the cause of the leakage problem. Step 10. If the DPV-1 is equipped with a Dry Pipe Valve Accelerator, reset the Dry Pipe Valve Accelerator in accord- ance with its Technical Data Sheet (Refer to TFP1100 for the QRS or TFP1112 for the ACC -1). Step 11. Partially open the Main Con- trol Valve. Slowly close the Main Drain Valve as soon as water discharges from the drain connection. Depress the plunger on the Automatic Drain Valve to make sure that it is open and that there is no water discharging. The absence of water discharging from the Automatic Drain Valve is an indication of a properly set water seat within the DPV-1 Valve. If water is dis- charging, refer to the Care and Main- tenance section under the Automatic Drain Valve Inspection to deter- mine/correct the cause of the leakage problem. If there are no leaks, the DPV-1 Valve is ready to be placed in service and the Main Control Valve must then be fully opened. NOTE Atter setting a fire protection system, notify the proper authorities and ad- vise those responsible for monitoring proprietary and/or central station alarms. Step 12. Once a week after a valve is reset following an operational test or system operation, the Low Body Drain Valve (and any low point drain valves) should be partially opened (and then subsequently closed) to relieve drain - back water. Continue this procedure until drain -back water is no longer pre- sent. NO C 0 C! TFP1041 Page 9 of 12 12" 6" 12" 14" (300 mm) (150 mm) (300 mm) (355 mm) O aP ® 17-1/4" 13-5/8" ® (440 mm) (346.1 mm) G or O dbQ or GxG DqP O DaPd O 2-1/2" (65 mm) FIGURE 6 4 INCH (DN100) MODEL DPV-1 DRY PIPE VALVE — NOMINAL INSTALLATION DIMENSIONS — Care and Maintenance The following procedures and inspec- tions should be performed as indi- cated, in addition to any specific re- quirements of the NFPA, and any impairment must be immediately cor- rected. The owner is responsible for the. in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stalling contractor or product manufac- turer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. NOTES The operational test procedure and waterflow pressure alarm test proce- dure will result in operation of the as- sociated alarms. Consequently, notifi- cation must first be given to the owner and the fire department, central sta- tion, or other signal station to which the alarms are connected. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection systems must first be obtained from the proper authorities and all personnel who may be affected by this decision must be notified. Annual Operation Test Procedure Proper operation of the DPV-1 Valve (i.e., opening of the DPV-1 Valve dur- ing a fire condition) should be verified at least once a year as follows: Step 1. If water must be prevented from flowing beyond the riser, perform the following steps. • Close the Main Control Valve. • Open the Main Drain Valve. • Open the Main Control Valve one turn beyond the position at which water just begins to flow from the Main Drain Valve. • Close the Main Drain Valve. Step 2. Open the system's Inspector's Test Connection. Step 3. Verify that the DPV-1 Valve has operated, as indicated by the flow of water into the system and that all wa- terflow alarms operate properly. Step 4. Close the system's Main Con- trol Valve. Step 5. Reset the DPV-1 Valve in ac- cordance with the Valve Setting Proce- dure. NOTE It is recommended that the require- ment of NFPA 25 to annually inspect the inside of the valve be performed at this time and prior to resetting the DPV-1 Valve. Refer to the Automatic Drain Valve Inspection sub -section Steps 2 through 5 for instructions with regard to the inspection of the Clapper Facing. Quarterly Waterflow Alarm Test Procedure Testing of the system waterflow alarms should be performed quarterly. To test the waterflow alarm, open the Alarm Test Valve, which will allow a flow of water to the Waterflow Pressure Alarm Switch and/or Water Motor Alarm. Upon satisfactory completion of the test, close the Alarm Test Valve. Water Pressure Inspection The Water Pressure Gauge is to be inspected monthly (per NFPA 25) to ensure that normal system water pres- sure is being maintained. Air Pressure Inspection The Air Pressure Gauge is to be in- spected monthly (per NFPA 25) to en- sure that normal system air pressure is being maintained. Page 10 of 12 Automatic Drain Valve Inspection The Automatic Drain Valve should be inspected monthly (per NFPA 25) by depressing the plunger and checking to ensure that the Automatic Drain Valve is not discharging water and/or air. A discharge of water and/or air is an indication that the air and/or water seats are leaking, which could sub- sequently cause a false operation should the intermediate chamber be- come inadvertently pressurized. If leakage is present, take the DPV-1 Valve out of service (i.e., close the main control valve, open the main drain valve, close the air supply control valve, remove the Dry Pipe Valve Ac- celerator from service, as applicable, in accordance with its Technical Data Sheet (Refer to TFP1100 for the QRS or TFP1112 for the ACC -1), and open the Inspector's Test Connection to re- lieve the system air pressure to 0 psig as indicated on the System Air Pres- sure Gauge), and then after removing the Handhole Cover, perform the fol- lowing steps: Step 1. Make sure that the Seat Ring is clean and free of any nicks or signifi- cant scratches. Step 2. Remove the Clapper Assem- bly from the valve by first pulling out the Hinge Pin. Step 3. Disassemble the Clapper Fac- ing Retainer from the Clapper so that the Clapper Facing can be removed and inspected. Make sure that the Clapper Facing does not show signs of compression set, damage, etc. Re- place the Clapper Facing if there is any signs of wear. Step 4. Clean the Clapper Facing, Clapper, and Clapper Facing Retainer, and then reassemble the Clapper As- sembly. Step 5. Reinstall the Clapper Assem- bly with its Hinge Pin and then reinstall the Handhole Cover. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, HEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. TFP1041 _13 Figure 590E � Check Valve CENTRAL Tyco Fire Products --- www.tyco-grooved.com 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA Customer Service/Sales: Tel: (215) 362-0700 / Fax: (215) 362-5385 Grooved Piping Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 FAGeneral ► Description See Fire Protection `UL VLC Submittal Sheet for FM pressure rating and Listing and Approval information Figure 590F Fire Protection Check Valves are furnished with grooved ends and can be installed using grooved couplings. The Figure 590F can be installed with ANSI class 150 Flanges utilizing our Figure 71 flange adapters and also ANSI class 300 Flange Adapters. All Figure 590F Check Valves have been designed with a removable cover for ease of field maintenance. They may be . installed in either horizontal or vertical piping systems. - A Maintenance Check Valve Kit is available to allow the maintenance procedure of backflushing through the fire department connection without removing the Figure 59OF Check Valve from the pipe line. Technical Data Figure: 590E zes: 2'/2", 3", 4", 5", 6" and 8" Aximum Working Pressure: 300 psi (2068 kPa) Factory Hydro Test: 100% at 600 psi (4 137 kPa) - Seat and Shell Complies with test requirements of MSS SP -71, UL, ULC and FM Approvals: UL, FM, and ULC; See Fire Protection Submittal Sheet for exact Listing /Approval information. Manufacturing Source: Domestic Body and Cap: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Clapper: Stainless Steel Seal: Grade "E" EPDM; See Gasket Grades and Recommendations Sheet for aid in selecting the proper seal. Protective Coatings: Valve Assembly — Non -lead orange paint Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fre Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OFANYAND ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITYAND FITNESS FORA PARTICULAR PURPOSE. No. 14-2.0 Ordering Procedure Ordering Information: When placing an order, indicate the full product name. Please specify the quantity, figure number, type of seal, EPDM "E", and size. Availability and Service: Grooved Piping Products, valves, accessories and other products are available throughout the U.S., Canada, and internationally, through a network of distribution .centers. You may write directly or call 215-362-0700 for the distributor nearest you. Figure 59OF Check Valve A CHECK VALVE -"- - `t< I 1/2" NPT 1/2" NPT - F Detail A B C D E F J Net Wt. Size Inches Inches Inches Inches Inches Inches Inches lbs. Steel, Zinc Plated MM mm mm mm mm mm mm Kg. 1 8.00 5.80 3.41 3.40 3.88 6.00 1.70 10.0 2'/2' 203.2 147.3 86.6 86.4 98.6 152.4 43.2 4.5 Retention Bolt 8.37 5.76 3.60 3.40 3.88 6.00 1.70 11.0 311 212.6 146.3 91.4 86.4 98.6 152.4 43.2 5.0 15 9.63 6.74 4.61 3.63 4.53 7.13 1.84 25.0 4 244.6 171.2 117.1 92.2 115.1 181.1 46.7 11.3 10.50 7.50 5.29 4.20 4.90 7.60 1.90 29.0 5 266.7 190.5 134.4 106.7 124.5 193.0 48.3 13.2 11.50 8.05 5.75 4.50 5.00 . 7.60 1.48 47.0 6 292.1 204.5 146.1 114.3 127.0 193.0 37.6 21.3 14.00 10.25 7.75 5.62 5.45 8.40 ` 2.20 66A F8 355.6 260.4 196.9 142.7 138.4 213.4 58.9 29.9 Detail Part Material Qty. 1 Body Ductile Iron 1 2 Cap Ductile Iron 1 3 Gasket Synthetic Fiber 1 4 Hex Cap Screw Steel, Zinc Plated AR 5 Clapper Stainless Steel or Ductile Iron 1 6 Seal Facing EPDM Grade "E" 1 7 Spring Stainless Steel 1 8 Hinge Shaft Stainless Steel 1 9 Retaining Ring Stainless Steel AR 10 Washer Teflon 2 11 Retention Bolt Stainless Steel 1 12 Seal Ring Neoprene 1 13 Retaining Disc Stainless Steel 1 14 Locknut Stainless Steel 1 15 Plug -Y'-14 NPT Cast iron 2 15 Adhesive Thread Sealer AR 16 Nameplate Aluminum 1 17 Rivet Steel 2 tgcc Flow Control Tyco Fire l Products VJ a Z a- 0 0 LU Z) rn co U-1 aI FLOW RATE (LPM) FLOW RATE (GPM) N Note: It is good piping practice to apply a safety factor of 15% to 20% to the values in the above table for design purposes. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the installation instructions (1H-1000). Never remove any piping component nor correct or modify any piping deficiencies without first depressurizing and draining the system. Material'and gasket selection should be verified to be compatible for the specific application. Printed in U.S.A. 4-01 10, 10 0 Butterfly Valve Figures 570 and 580 Tyco Fire Products --- www.tyco-grooved.com 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA Customer Service/Sales: Tel: (215) 362-0700 / Fax: (215) 362-5385 Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 rGeneral , Description V�C CFM ire Protection tal Sheet for sting and Listing ival information Figures 570 and 580 Butterfly Valves are specifically designed to provide for efficient control .of fire protection water supplies. The Figure 570 is designed to operate in systems up to and including 175 psi. The Figure 580 is designed to meet the increasing pressure requirements of the Fire Protection Industry with a maximum operating pressure of 300 psi. Flow may be from either direction, and the valves may be positioned in any orientation. The valves are furnished with grooved ends and can be easily adapted to flanged components utilizing our Figure 71 Class 150 flange adapters. The body,and disc construction provides for increased strength and durability. The Figure 570 and 580 Butterfly Valves are provided with 2 sets of SPDT Supervisory Switches for use in outdoor and indoor applications. A high strength conventional stainless steel upper stem is provided for dependability as compared to iron upper stems provided by others. The surfaces at the upper stem and lower trunnion areas incorporate a reduced dynamic torque and anti -compression set esign to ensure tow operating torque and ��creased seal longevity. This innovative feature prevents elastomeric failure of the disc encapsulation that is commonly experienced with other manufacturers. This is accomplished by providing uniform compression throughout the opening and closing operation of the disc. Other manufacturers have non-uniform compression, which results in permanent compression set and subsequent splitting of the material and undermining of the seal. Technical Data Figure: 570 and 580 Sizes: 570 - 2'/z', 3", 4", 5", 6", 8", 10" and 12" 580 - 2'/z , 3" 4" 5" 6" 8",10' and 12" Max. Working Pressure: Figure 570 =175 psi (1,207 kPa) Figure 580 = 300 psi (2,068 kPa) Approvals: UL, FM, and ULC (indoor and outdoor use) Note:The 8" -12" Figure 580 are FM Approved only. Manufacturing Source: Domestic Materials of Construction: Body: Ductile iron in accordance with ASTM A-536, Grade 65-45-12 Body Coating: Orange Epoxy Disc: Ductile Iron in accordance with ASTM A-536, Grade 65-45-12, Disc Seat: Grade E EPDM encapsulated rubber in accordance with ASTM D-2000 See Gasket Grades and Recommendations Sheet for aid in selecting the proper seal. Upper Stem: (Figures 570 & 580) Type 440 Stainless Steel (21/2"- 8") Type 17-4 Stainless Steel (10" -12") Lower Plug/Stem: Figure 570: C360 Brass (2'/2" - 8") Type 17-4 Stainless Steel (10" -12') Lower Stem: Figure 580: Type 17-4 Stainless Steel (2'/2' - 12') Operator: Gear operator with.lron housing - coated with Black Epoxy. Bracket: Steel - Black Zinc Plated Factory Hydro Test: 100% @ two times pressure rating in accordance with MSS -SP -67, UL, ULC, and FM requirements. CENTRAL Grooved Piping Products rAInstallation In piping systems, butterfly valves should be located where they will be readily accessible for operation, inspection, and maintenance. When a valve 'closes hard", it may be due to debris lodged in the sealing area. This may be corrected by backing -off the handwheel and closing it again, several times if necessary. The valve should never be forced to seat by applying a wrench to the handwheel as it may distort the valve components or score the sealing surfaces. Before installing conduit at the actuator, remove the rubber grommet at the connection. Important: All replacement parts must be obtained from the manufacturer to assure proper operation of the valve. To prevent rotation of the valve, it is recommended that the Butterfly Valve be installed with rigid type couplings, such as the Figure 572 or 772 Coupling. If flexible couplings are used, additional support may be needed to prevent rotation. Ordering 1!]Procedure Ordering Information: When placing an order, indicate the full product name. Please specify the quantity, figure number, type of disc seal, EPDM "E", and size. Availability and Service: Grooved Piping Products, valves, accessories and other products are available throughout the U.S„ Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. No. 15-3.0 installing contractor or product Limited Care a n d manufacturer should be contacted 11 relative to any questions. Any Warranty Maintenance opair ent must be immediately Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF -SUCH DAMAGES, AND. IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OFANYAND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITYAND FfTNESS FOR A PARTICULAR PURPOSE. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The Front view with valve open Friction Resistance Equiv. Size Length in Feet 21/2 6' 3" 7' 4" 6' 5" 10' 6" 13' 8" 14' 10" 16' 12" 18' It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Figures 570 and 580 A Switch Rating: POSITION INDICATOR i Supervisory Tamper Fire Alarm 10A 125, 250 VAC p Control Panel E Switch Circuits supe visory 0.25A 250 UDC G (valve Fully open) Circuit 0.50A 125 VDC ! CS1 NC BLK NO RED End of Line Inches conk Resistance i WHT Or, Next Device i NC BLWDRN voltage I S2 NO - _ .L CHASSIS COM RjSource ._. I i JG WHT/ORNWIRING G /� DIAGRAM E Utilization and Connection of Auxiliary Switch Side view with to be Reviewed and Approved by the Loral Authority Having Jurisdiction valve open 7.22 * END OF DISC DOES NOT EXTEND BEYOND VALVE BODY. Note: Contact Tyco Fire Products for 10" and 12" availability. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the installation instructions (I1-1-1000). Never remove any piping component nor correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. ISO •0• CompanyCertified twa FlowControlTyco Fire Printed in U.S.A. 4-01 l /Products Q A B C D E F G Weight: Size Inches Inches Inches Inches Inches Inches Inches Lbs. mm mm mm mm mm mm mm Kg. 5.34 10.41 7.22 2.88 3.81 5.72 12.0 21/2" 135.6 264.4 183.4 73.0 96.8 145.3 N/A* 5.4 5.67 11.38 8.75 3.50 3.81 5.72 14.0 3" 1 144.0 289.1 222.31 88.9 96.8 1 145.3 N/A* 6.4 6.76 12.70 9.65 4.75 4.56 5.72 22.0 4" 171.7 322.6 245.1 1 120.7 115.8 145.3 N/A* 10.0 7.15 14.56 10.23 6.25 5.81 6.18 31.0 5° 181.6 369.8 259.8 158.8 147.6 157.0 1 N/A* 14.1 7.88 15.23 10.96 6.75 5.81. 6.18 36.0 6" 200.2 386.8 278.4 171.5 147.6 157.0 N/A* 1 16.3 9.24 17.50 13.37 10.00 5.25 6.43 1.22 52.0 8" 234.7 444.5 339.6 254.0 133.4 163.3 31.0 1 23.6 11.81 21.78 16.93 12.00 6.25 7.96 1.75 75.0 299.9 553.2 430.0 304.3 158.8 202.2 44.5 34.1 t 12.97 24.11 19.10 14.27 6.50 8.83 2.60 90.0329.4 612.4 485.1 1362.5 1 165.1 224.3 1 66.0 40.9 * END OF DISC DOES NOT EXTEND BEYOND VALVE BODY. Note: Contact Tyco Fire Products for 10" and 12" availability. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the installation instructions (I1-1-1000). Never remove any piping component nor correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. ISO •0• CompanyCertified twa FlowControlTyco Fire Printed in U.S.A. 4-01 l /Products Q O Grooved Fittings Figures 501 510 and 519 Patent Pending Tyco Fire Products --- www.tyco-grooved.com 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA Customer Service/Sales: Tel: (215) 362-0700 / Fax: (215) 362-5385 Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 General Description Grooved fittings provide an economical and efficient method of changing direction, adding an outlet, reducing, or capping grooved piping systems. Figure 500 fittings are available in durable ductile iron. Technical Data Figure: 501, 510, 519 Sizes: 1'/4" - 8" Maximum Working Pressure: 300 psi; See specific data sheet for rating of coupling being used. Approvals: UL, FM, and ULC Note: See Fire Protection Submittal Sheet for exact Listing/Approval information. Manufacture Source: Domestic Material: Ductile iron, conforming to OASTM A-536 Grade 65-45-12 - Protective Coatings: • Non -lead orange paint • Fire Brigade red (optional) non -lead • Hot dipped galvanized conforming to ASTM A-153 Ordering Procedure Ordering Information: When placing an order, indicate the full product name. Please specify the quantity, figure number and size. Availability and Service: Grooved Piping Products, valves, accessories and other products are available throughout the U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for,and properly installed and maintained under normal use and CENTRAL Grooved Piping Products service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING "BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED. INCLUDING WARRANTIES OF MERCHANTABILITYAND FITNESS FOR A PAR77CULAR PURPOSE. No. 18-1.1 c1 Figure 501 i CtoE i i �-- C to E Figure 510 - C to E ----------------- ----------------- C t E --------- -CtoE i Figure 519 General Nates: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the installation instructions (IH -1000). Never remove any piping component nor correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. twO Flow Control Tyco Fire Printed in U.S.A. 4-01 l Products Figure 501 Figure 510 Figure 519 450 Elbow 900 Elbow Tee Nominal C to E Appx. Wt. C to E Appx. Wt. C to E Appx. Wt. Size Inches Lbs. Inches Lbs. Inches Lbs. Inches mm Kg. mm Kg. mm Kg. 1.75 0.8 2.75 1.0 2.75 1.4 1,�4 44.5 0.4 69.9 0.5 69.9 0.6 1.75 1.0 2.75 1.4 2.75 1.8 1 V2 44.5 0.5 69.9 0.6 69.9 0.8 2.00 1.3 3.25 1.8 3.25 2.6 2 50.8 0.6 82.6 0.8 82.6 1.2 2.25 1.9 3.75 2.7 3.75 3.9 2'/2 57.2 0.9 95.3 1.2 95.3 1.8 2.50 2.6 4.25 3.7 4.25 5.4 3 63.5 1.2 108.0 1.7 108.0 2.4 3.00 5.0 5.00 7.0 5.00 10.1 4 762 2.3 127.0 3.2 127.0 4.6 3.50 8.6 6.50 13.4 6.5 18.8 6 88.9 3.9 1 165.1 6.1 165.1 8.5 4.25 17.2 7.75 26.3 7.75 36.3 8 1 108.0 7.8 196.9 11.9 196.9 16.5 General Nates: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the installation instructions (IH -1000). Never remove any piping component nor correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. twO Flow Control Tyco Fire Printed in U.S.A. 4-01 l Products Flexible Coupling � Figure 575 Patent Pending CENTRAL Tyco Fire Products --- www.tyco-grooved.com 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA Customer Service/Sales: Tel: (215) 362-0700 / Fax: (215) 362-5385 Grooved Piping Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 General Description 0 See Fire Protection Submittal Sheet for pressure rating and Listing and Approval information Figure 575 Flexible Couplings are capable of pressures up to 300 psi depending on pipe size and wall thickness. It provides a dependable method of joining pipe and is suitable for use in a variety of applications. The Figure 575 incorporates "gripping teeth" along the coupling keys which increase the rotation resistance of the product when pressurized, while still allowing for linear and angular misalignment. 101 Technical Data Figure: 575 Sizes: 1114"- 8" Approvals: UL, FM, and ULC; See Fire Protection Submittal Sheet for exact Listing /Approval information. Manufacturing Source: Domestic Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: • Non -lead orange paint • Fire Brigade Red (optional) non -lead • Hot dipped galvanized conforming to ASTM A-153 SoWNuts: Track Head Bolts - conforming to ASTM A-183, Zinc Plated, (Min. Tensile = 110,000 psi) Gasket: (specify when ordering) • Grade A EPDMA violet color code ambient - to +150OF (+66,C) for fire protection systems. Not recommended for hot water systems. • Tri -Seal (Grade E EPDM) green color code • Prelubricated (Grade A EPDMA) • Prelubricated Tri -Seal (Grade E EPDM) (See Gasket Grades and Recommendations Sheet for aid in selecting the proper gasket) Note: Rigid Couplings are recommended for dry pipe and freezer applications. rl Ordering Procedure Ordering Information: When placing an order, indicate the full product name. Please specify the quantity, figure number, type of gasket, EPDM "A" or "E" Tri -Seal, and size. Availability and Service: Grooved Piping Products, valves, accessories and other products are available throughout the U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. No. 18-1.2 Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN Figure 575 Flexible Coupling CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OFANYAND ALL OTHER WARRAN7IES EXPRESS OR IMPLIED. INCLUDING WARRANTIES OF MERCHANTABILfrYAND FITNESS FOR A PARTICULAR PURPOSE. Pipe Max. * End Gap Max.t Pressure Max.t End Load Dimensions Deflection$ Bolt Net Wt 0. D. A B C Inches/ Size Inches Inches psi Lbs. Inches Inches Inches oPer Foot ze ix Lbs. MM mm kPa N mm mm mm Co pl ng mm/m Dia. Lg. Kg. 1.660 0.09 300 650 2.48 4.07 1.69 0.67 0.9 11/4 42.2 2.3 2,068 2,891 63.0 103.4 42.9 30 13' 55.8 3/8, x 21/4" 0.4 1.900 0.09 300 1,083 2.72 4.32 1.69 0.59 1.0 11/2 48.3 2.3 2,068 4,817 69.1 109.7 42.9 20 - 48' 49.2 8/8" x 21/4" 0.5 2.375 0.09 300 1,329 3.22 4.82 1.69 0.47 1.2 2 60.3 2.3 2,068 5,912 81.8 122.4 42.9 20 - 15' 39.2 s/8" x 21/4" 0.5 2.875 0.09 300 1,948 3.72 5.38 1.72 0.39 1.3 2 /z' 73.0 2.3 2,068 8,665 94.5 136.7 43.7 10 - 51' 32.5 3/8" x 21/4" 0.6 3.500 0.09 300 2,886 4.38 6.06 1.72 0.32 1.7 3 88.9 2.3 2,068 12,838 111.3 153.9 43.7 10 - 31, 26.7 3/8" x 21/4" 0.8 4.500 0.19 300 4,771 5.58 7.38. 1.80 0.50 2.7 4 114.3 4.8 2,068 21,222 141.7 187.5 45.7 20 24, 41.7 3/8" x 21/4" 1.2 6.625 0.19 300 10,341 7.86 9.88 1.88 0.34 5.3 6 168.3 4.8 2,068 45,999 199.6 251.0 47.8 1 38' 28.3 1/2" x 3" 2.4 8.625 0.19 300 17,527 10.06 12.66 2.25 0.26 7.2 8 219.1 4.8 2,068 77,964 255.5 321.6 57.2 1 16' 21.7 ,h" x 3" 3.3 Contact Tyco Fire Products for V' availability. * Maximum available gap between pipe ends. Minimum gap = 0. t Maximum pressure and end load are total from ail loads based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. Contact Tyco Fire Products for details. See Fire Protection Equipment Submittal Sheet for Listing and Approval pressure ratings. $ Max end gap and deflection are for cut groove standard weight pipe: Values for roll groove pipe will be Y2 that of cut groove. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand ISo the installation instructions (I1-1-1000). Never remove any piping component nor correct or modify 9001 any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. Certified Company tqCO Flow ControlITyo.-,Ou Fire Printed in U.S.A. 4-01 l cts OgRigideCoupling � Patented Tyco Fire Products --- www.tyco-grooved.com CENTRAL 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA Customer Service/Sales: Tel: (215) 362-0700 / Fax: (215) 362-5385 GPOOved Piping Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 P 9 Product Technical Ordering Description Data Procedure V1 Figure: 572 Ordering Information: When placing an Sizes: 11/4" - 8" order, indicate the full product name. Please Approvals: UL, FM, and ULC; See Fire Protection specify the quantity, figure number, type of Submittal Sheet for exact Listing/Approval gasket, EPDM "A" or "E" Tri -Seal, and size. information. R VULq See Fire Protection O SubmittalSheet fior pressure FM rating and Listing and Approval information Figure 572 Rigid Couplings are capable of pressures up to 300 psi and provides a rigid joint by firmly gripping along the circumference of the pipe grooves. Rigid Couplings are preferred for dry pipe and freezer applications. Figure 572 Rigid Couplings are a proven dependable method of joining pipe and are an economical alternative to welding, threading or using flanges, and can be used on a variety of pipe material and wall thicknesses. The Figure 572 Coupling has an Anti - Rotation Feature of "gripping teeth" along the coupling keys which make the Figure 572 perfectly suited for "arm over" installations where the likelihood of rotation is greatest. This feature may eliminate the need of extra hangers to support the arm over due to increased rigidity and gripping force saving time and cost. Manufacturing Source: Domestic Housing: Ductile iron - conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: • Non -lead orange paint • Fire Brigade red (optional) non -lead • Hot dipped galvanized conforming to ASTM A-153 Bolt/Nuts: Track Head Bolts - conforming to ASTM A-183, Zinc Plated, (Min. Tensile =110,000 psi) Gasket: (specify when ordering) • Grade A EPDMA violet color code ambient to +150°F (+66°C) for fire protection systems. Not recommended for hot water systems. • Tri -Seal (Grade E EPDM), green color code, for use in dry pipe or freezer systems. • Prelubricated (Grade A EPDMA) • Prelubricated Tri=Seal (Grade E EPDM) (See Gasket Grades and Recommendations Sheet for aid in selecting the proper gasket) Note: Rigid Couplings are recommended for dry pipe and freezer applications. Availability and Service: Grooved Piping Products, valves, accessories and other products are available throughout the U.S Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. No. 18-1.3 Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire 'Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN Figure 572 Grooved Coupling CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OFANYAND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITYAND FITNESS FOR A PARTICULAR PURPOSE Pipe Max. * End Gap Max.t Pressure Max.t End Load Dimensions Bolt Size Net Wt. O.D. A B G Size Inches : Inches psi Lbs. Inches Inches Inches Dia. x Lg. Lbs. MM mm kPa N mm mm mm Kg. 1.660 0.06 300 650 2.56 4.09 1.693/B" x 2Ya" 0.9 1 /4" 42.2. 1.5 2,068 2,891 65.0. 103.9 42.9 0.4 1.900 0.06 300 850 2.81 4.38 1:81 W x 21/4" 1.0 1 /z" 48.3 1.5 2,068 3; 783 71.4 111.3 46.0 0.5 2.375 0.06 300 1,329 3.31 4.82 1.88 W x 21/4' 12 2" 60.3 1.5 2,068 5,914 84.1 122.4 47.8 0.5 2.875 0.06 300 1,948 3.81 5.38 1.88 W 21/4" 1.3 2 /z" 73.0 1.5 2,068 8,668 96.8 136.7 47.8 0.6 3.500 0.06 300 2,886 4.50 6.06 1.88 W x 21/4" 1.7 3" 88.9 1.5 2,068 12,843 114.3 153.9 47.8 0.8 4.500 0.19 300 4,771 5.69 7.38 1.88 x 21/4" 2.7 4" 114.3 4.8 2,068 21,231 144.5 187.5 47.8 1.2 6.625 0.19 300 10,341 7.94 9.88 1.88 1/z" x 3" 5.3 6" 168.3 4.8 2,068 46,018 201.7 251.0 47.8 2.4 8.625 0.19 300 17,528 10.13 12.69 2.25 1/2" x 3" 7.2 8" 219.1 4.8 2,068 1 78,000 257.3 322.3 57.2 3.3 Contact Tyco fire Products for 8" availability. Maximum available gap between pipe ends. Minimum gap = 0. t Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. Contact Tyco Fire Products for details. See Fire Protection Equipment Submittal Sheet for Listing and Approval pressure ratings. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that ISO pressure ratings and performance data is not exceeded. Always read and understand the installation instructions 9001 (I1-1-1000). Never remove any piping component nor correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. Certified Company t[JCO Flow Controll Tyco Fire Printed in U.S.A. 4-01 / Products 01 Q Flexible Reducing Coupling � Figure 716 Tyco Fire Products --- www.tyco-grooved.com 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA Customer Service/Sales: Tel: (215) 362-0700 / Fax: (215) 362-5385 Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 iso Product Description UL ULC See Fire Protection FM Submittal Sheet for pressure rating and Listing and Approval information The Figure 716 Flexible Reducing Coupling allows a direct transistion between two different pipe sizes, and replaces two couplings and a reducing fitting. Note: Reducing Couplings are not recommended for dry pipe and freezer applications. Technical Data Figure: 716 Sizes: 2" x 11/2 - 8" x 6" Approvals: UL, FM, and ULC; See Fire Protection Submittal Sheet for exact Listing/Approval into. Manufacturing Source: Domestic Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: • Non -lead orange paint • Hot dipped galvanized conforming to ASTM A-153 Bolt/Nuts: Track Head Bolts - conforming to ASTM A-183, Zinc Plated, (Min. Tensile =110,000 psi) Gasket: (specify when ordering) • Grade E EPDM green color code • Prelubricated (Grade'E EPDM) (See Gasket Grades and Recommendations Sheet for aid in selecting the proper gasket) Ordering Information Ordering Information: When placing an order, indicate the full product name. Please specify the quantity, figure number, type of gasket, EPDM "E", and size. Availability and Service: Grooved Piping Products, valves, accessories and other products are available throughout the U.S., Canada, and internationally, through a network of distribution centers. You may write directly or ca11215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed CENTRAL Grooved Piping Products and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OFANYAND ALL OTHER WARRANTIES EXPRESS OR MIRL ED. INCLUDING WARRANT7ES OF MERCHANTABILITYAND FITNESS FOR A PART7CULAR PURPOSE. No. 18-3.0 Figure 716 Grooved Coupling Pipe Max. `$ End Gap Max.t Pressure Max.t End Load Dimensions Deflection $ Bolt Net Wt 0. D. A B C Inches/ Size Inches Inches psi Lbs. Inches Inches Inches °Per Foot Size Lbs. MM mm kPa N mm mm mm Coupling mm/m Dia. x Lg. Kg 2.375 x 1.900 0.13 350 992 3.50 5.06 1.88 0.39 2.0 2 x 1 /z 60.3 x 48.8 3.3 2,413 4,412 88.9 128.5 47.8 1 ° - 53 32.9 ale° x 2'/4 0.9 2.875 x 2.375 0.13 350 1,550 4.00 5.50 1.88 0.32 2.5 2'/z' x 2 73.0 x 60.3 3.3 2,413 6,894 101.6 139.7 47.8 11 - 33' 27.0 ale" x 21/4 1.1 3.500 x 2.375 0.13 350 1,550 4.69 6.50 1.88 3` 4.5 3" x 2" 88.9 x 60.3 3.3 2,413 6,894 119.1 165.1 47.8 1 ° -17 22.4 1/2'x 3° 2.0 3.500 x 2.875 0.13 350 2,271 4.69 6.50 1:88 0.27 4.6 3" x 2'/z 88.9 x 73.0 3.3 2,413 10,101 119.1 165.1 47.8 10 - 17 22.4 '/z" x 3" 2.1 4.500 x 2.375 0.19 350 1,550 6.00 8.13 2.00 0.55 6.0 4" x 2" 114.3 x 60.3 4.8 2,413 6,894 152.4 206.5 50.8 2° - 38 45.9 s/e" x 3'/4" 2.7 4.500 x 2.875 0.19 350 2,271 6.00 8.13 2.00 0.55 6.1 4" x 2'/z° 114.3 x 73.0 4.8 2,413 10,101 152.4 " 206.5 50.8 2° - 38' 45.9 s/e" x 31/4° 2.8 4.500 x 3.500 0.19 350 3,366 6.00 8.13 2.00 0.55 6:2 4" x 3" 114.3 x 88.9 4.8 2,413 14,972 152.4 206.5 50.8 2° 38 45.9 5/e` x 3'/4" 2 8 5.563 x 4.500 0.25 350 5,564 7.13 9.56 2.06 0.44 10.1 5" x 4° 141.3 x 114.3 6.4 2,413 24,749 181.1 242.8 52.3 20 - 5 36.4 3/4" x 431x" 4.6 6.625 x 4.500 0.25 300 4,769 8.38 10.88 2.06 0.36 11.6 6" x 4" 168.3 x 114.3 6.4 2,068 21,213 212.9 276.4 52.3 1 ° 44 30.2 3/4" x 43/4" ; 5.3 ,, 6.625 x 5.563 0.25 300 7,288 8.38 10.88 2.06 - 0.36 11.7 . 6" x 5" 168.3 x 141.3 6.4 2,068 32,417 212.9 276.4 52.3 1 11 - 44' 30.2 3/4" x 43/4" 5.3 8.625 x 6.625 0.25 300 10,336 10.69 13.75 2.25 0.26 21.6 8" x 6° 219.1 x 168.3 6.4 2,068 1 45,975 1 271.5 349.3 1 57.2 1 1 ° -15' 21.8 '/e" x 61I2" 9.8 Maximum available gap between pipe ends. Minimum gap = 0.06" (with metal Insert). t Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. Contact Tyco Fire Products for details. See Fire Protection Equipment Submittal Sheet for Listing and Approval pressure ratings. $ Max End Gap and Deflection is for cut grooved standard weight pipe. Values for roll grooved pipe will be 1/2 that of cut grooved. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the installation instructions (11-1-1000). Never remove any piping component nor correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. ty(;Q Flow Control/Products Tyco Fire l Printed in U.S.A. 4-01 64 P O 0 CFIange Adapter Figure 71 Tyco Fire Products --- www.tyco-grooved.com CENTRAL 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA Customer Service/Sales: Tel: (215) 362-0700 / Faz: (215) 362-5385 Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Grooved Piping Products General � Description VL ULC FM See Fire Protection Submittal Sheet for pressure rating and Listing and Approval information C',,he Figure 71 Flange Adapter allows a irect transition from flanged components into a grooved piping system. Flange bolt patterns conform to ANSI Class 125 and 150 standards. Technical Data Figure: 71 Sizes: 2'- 12" Approvals: UL, FM, and ULC See Fire Protection Submittal Sheet for exact Listing /Approval information. Manufacturing Source: Domestic Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: • Non -lead orange paint • Hot.dipped galvanized conforming to C. ASTMA-153 ,ket: (specify when ordering) Grade E EPDM green color code • Prelubricated (Grade E EPDM) (See Gasket Grades and Recommendations Sheet for aid in selecting the proper gasket) Ordering Procedure Ordering Information: When placing an order, indicate the full product name. Please specify the quantity, figure number, type of gasket, EPDM "E", and size. Availability and Service: Grooved Piping Products, valves, accessories and other products are available throughout the U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. -11 Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association . (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OFANYAND ALL OTHER WARRAN77ES EXPRESS OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILJTYAND FITNESS FOR A PARTICULAR PURPOSE. No. 18-8.0 Figure 71 Flange Adapter A C7 r i F B E D i �I Pipe Max t Pressure Max t End Load Dimensions Bolts t Net Wt. A B C "D "E F Size Size O.D. psi Lbs. Inches Inches Inches Inches Inches Inches Dia. x Lg. Oty. lbs. kPa N mm mm mm mm mm mm kg 250 1,107 6.38 4.75 0.75 2.38 3.41 7.25 $/e° x 3" 4 3.0 2" 2.375" 1,724 4,924 162.1 120.7 19.1 60.5 86.6 184.2 1.4 250 1,622 7.00 5.50 0.88 2.88 3.91 7.88 Sla" x 3" 4 5.0 2'/z° 2.875" 1,724 7,215 178.0 140.0 22:0 73.0 99.0 200.0 2.3 250 2,404 7.50 6.00 0.94 3.50 4.53 9.88 sl8" x 3° 4 5.6 3" 3.500° 1,724 10,693 190.5 152.4 23.9 88.9 115.1 251.0 2.5 250 3,974 9.00 7.50 0.94 4.50 5.53 9.90 ele" x 3" 8 7.0 4" 4.500" 1,724 17,676 228.6 190.5 23.9 114.3 140.5 251.5 3.2 250 6,073 10.00 8.50 1.00 5.56 6.72 11.38 3/a° x 3'/z 8 9.2 5" 5.563° 1,724 27,013 254.0 215.9 25.4 141.2 170.7 289.1 4.2 250 8,614 11.00 9.50 1.00 6.62 7.78 11.88 3/'" x 3'/z" 8 10.0 6° 6.625" 1,724 38,315 279.4 241.3 25.4 168.1. 197.6 301.8 4.5 250 14,599 13.50 11.75. 1.13 8.62 9.94 14.38 3l'° x 3'/z" 8 16.6 8" 8'625° 1,724 64,936 342.9 298.5 28.7 218.9 252.5 365.3 7.5 250 22,679 16.00 14.25 119 10.75 12.31 16.88 'I x 4" 12 21.8 10" 10.750" 1,724 100,876 406.4 362.0 30.2 273.1 312.7 428.8 a" 9.9 250 31,903 19.00 17.00 1.25 12.75 14.31 20.00 'I8" x 4" 12 24.2 12" 12.750" 1,724 141, 905 482.6 43.1.8 31.8 , 323.9 363.5 508.0 11.0 Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. Contact Tyco Fire Products for details. See Fire Protection Equipment Submittal Sheet for Listing and Approval pressure ratings. Dimensions D and E represent minimum and maximum sealing surfaces. Bolts and Nuts are not supplied. Boit lengths are standard; it is the responsibility of the purchaser to verify correct length for the intended application. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the installation instructions (IH -1000). Never remove any piping component nor correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. 7 ica How Control Tyco Fire l Products Printed in U.S.A. 4-01 0 Mechanical Tees a Figure 730 Threaded / Grooved Tyco Fire Products --- www.tyco-grooved.com CENTRAL 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA Customer Service/Sales: Tel: (215) 362-0700 / Fax: (215) 362-5385 Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Grooved Piping Products General (See Gasket Grades and Recommendations when paid for and properly installed Sheet for aid in selecting the proper gasket) and maintained under normal use and service. This warranty will expire ten Description(10) years from date of shipment by Ordering Tyco Fire Products. No warranty is The Figure con manufactured by companies not Mechanical Tees may be used given for products or components Information for any tee connection where a threaded or affiliated by ownership with Tyco Fire grooved outlet is needed. They may be Products or for products and converted into a cross when necessary. Ordering information: When placing P an order, indicate the full product name. components which have been subject UL U C Please specify the quantity, figure number, to misuse, improper installation, FM type of gasket, EPDM "E", and size. ® corrosion, or which have not been Availability and Service: Grooved installed, maintained, modified or Piping Products, valves, accessories and repaired in accordance with applicable other products are available throughout the Standards of the National Fire U.S., Canada, and internationally, through a Protection Association (NFPA), and/or network of distribution centers. You may the standards of any other Authorities See Fire Protection write direct) or call 215-362-0700 for the Having Jurisdiction. Materials found by Submittal Sheet for Y co Fire Products to be defective shall 0 pressure rating and distributor nearest you. Tyco Listing and Approval be either repaired or replaced, at Tyco information Fire Products' sole option. Tyco Fire Technical Care and Products neither assumes, nor authorizes any person to assume for it, NJ any other obligation in connection with DataMaintenance the sale of products or parts of The owner is responsible for the products. Tyco Fire Products shall not Figure: • 730 be responsible for sprinkler system 9 inspection, testing, and maintenance of design errors or inaccurate or Outlet: Threaded & Grooved their fire protection system and devices incomplete information at lied b Max. Working Pressure: in accordance with the applicable inBuyer or Buyer's representatives.pp y 300 psi (2068 kPa) standards of the National Fire Note: Maximum pressure applies to the Protection Association (e.g., NFPA 25), IN NO EVENT SHALL TYCO FIRE Mechanical Tee. When connected to a in addition to the standards of any PRODUCTS BE LIABLE, IN grooved coupling,the rating will be the authority having jurisdiction. The CONTRACT, TORT, STRICT lesser of the Mechanical Tee or Coupling installing contractor or product LIABILITY OR UNDER ANY OTHER rating. Maximum pressure is a total from all manufacturer should be contacted LEGAL THEORY, FOR INCIDENTAL, loads, based on standard weight or Sch. 10 relative to any questions. Any INDIRECT, SPECIAL OR steel pipe. For pipe with other wall thickness impairment must be immediately CONSEQUENTIAL DAMAGES, or materials contact Tyco Fire Products. corrected. INCLUDING BUT NOT LIMITED TO Approvals: UL, FM, and ULC; It is recommended that automatic LABOR CHARGES, REGARDLESS OF See Fire Protection Submittal Sheet for sprinkler systems be inspected, tested, WHETHER TYCO FIRE PRODUCTS exact Listing /Approval info. and maintained by a qualified WAS INFORMED ABOUT THE Manufacturing Source: Domestic Inspection Service. POSSIBILITY OF SUCH DAMAGES, Housing: Ductile iron conforming to AND IN NO EVENT SHALL TYCO ASTM A-536, Grade 65-45-12 FIRE PRODUCTS' LIABILITY EXCEED Protective Coatings: Limited AN AMOUNT EQUAL TO THE SALES • Non -lead orange paint PRICE. O• Hot dipped galvanized conforming to Warranty THE FOREGOING WARRANTYIS MADE ASTM A-153 IN LIEU OFANYAND ALL OTHER Bolt/Nuts: Track Head Bolts - Products manufactured by Tyco Fire WARRANTIES EXPRESS ORIMPUED conforming to ASTM A-183, Zinc Plated, Products are warranted solely to the INCLUDING WARRANTIES OF (Min. Tensile =110,000 psi) original Buyer for ten (10) years against MERCHANTABIUTYAND FITNESS Gasket: (specify when ordering) defects in material and workmanship FORA PARTICULAR PURPOSE. • Grade E EPDM green color code No. 18-6.0 TAI :01 Figure 730 Mechanical Outlet Tee and Cross (Threaded) I1' LJ Figure 730 Mechanical Outlet Tee (Threaded) TA TAI Figure 730 Mechanical Outlet Cross (Threaded) Nom. Size Hole Dia.$ Dimensions Net Hole Max. A B C D E Wt. Run x Branch Inches Inches Inches Inches Inches Inches Inches Lbs. MM mm mm mm mm mm mm Kg. 1.50 1.63 2.62 4.88 3.07 2.12 1.59 2.2 2" x'/2", 3/4° 1" 38.1 41.3 66.5 124.0 78.0 53.8 40.4 1.0 1.75 1.88 2.78 4.88 3.32 1.93 1.59 2.5 2" x 11/4" 44.5 47.6 70.6 124.0 84.3 49.0 40.4 1.1 1.75 1.88 2.62 4.88 3.32 1.93 1.59 2.5 2" x 11/2' 44.5 47.6 66.5 124.0 84.3 49.0 40.4 1.1 1.50 1.63 2.88 5.25 3.07 2.38 1.81 2.7 21/2'x 1h", 314" 1. 38.1 41.3 73.2 133.4 78.0 60.5 46.0 1.2 21/2„ x 11/4" 2.00 2.13 3.00 5.25 3.56 2.19 1.81 3.1 50.8 54.0 76.2 133.4 90.4 55.6 46.0 1.4 2.00 2.13 3.07 5.25 3.59 2.17 1.81 3.3 21/2" x 11/2" 50.8 54.0 78.0 133.4 91.2 55.1 46.0 1.5 1.50 1.63 3.19 6.13 3.07 2.56 2.21 3.7 3"x 1/2", 314", 1" 38.1 41.3 81.0 155.7 78.0 65.0 56.1 1.7 1.75* 1.88 3.34 6.13 3.32 2.50 2.21 3.9 3" x 11/4" 44.5 47.6 84.8 155.7 84.3 63.5 56.1 1.8 2.00 2.13 3.38 6.13 3.56 2.48 2.21 4.2 3" x 1112" 50.8 54.0 85.9 155.7 90.4 63.0 56.1 1.9 2.50 2.63 3.50 6.13 4.09 2.75 2.21 4.7 3" x 2" 63.5 66.7 88.9 155.7 103.9 69.9 56.1 2.1 4" x 1/2", 3/4", 1" 1.50 1.63 3.69 7.13 3.07 3.06 2.78 5.5 38.1 41.3 93.7 181.1 78.0 77.7 70.6 2.5 1.75' 1.88 3.92 7.13 3.32 3.00 2.78 5.5 4" x 1114" 44.5 47.6 99.6 181.1 84.3 76.2 70.6 2.5 2.00 2.13 4.00 7.13 3.56 2.98 2.78 5.5 4" x 11/2" 50.8. 54.0 101.6 181.1 90.4 75.7 70.6 2.5 2.50 2.63 4.00 7.13 4.06 3.25 2.78 6.0 4" x 2" 63.5 66.7 101.6 181.1 103.1 82.6 70.6 2.7 2.75 2.88 4.00 7.13 4.38 3.12 2.78 6.0 4" x 21/2" 69.9 73.0 101.6 181.1 111.3 79.2 70.6 2.7 2.75 2.88 4.00 7.13 4.38 3.12 2.78 6.0 4" x 76.1 mm 69.9 73.0 101.6 181.1 111.3 79.2 70.6 2.7 3.50 3.63 4.13 1 7.13 5.13 3.31 2.78 7.0 4" x 3" 1 1 88.9 92.1 104.9 181.1 130.3 84.1 70.6 3.2 - Hole size for 3" x 1114" and 4" x 11/4" changed from 2" previously on Figure 720. W 101 Figure 730 Mechanical Outlet Tee and Cross (Threaded) Nom. Size Hole Dia.$ Dimensions Net Hole Max. A B C D E Wt. Run x Branch Inches Inches Inches Inches Inches Inches Inches Lbs. mm mm mm mm mm mm mm Kg. 2.00 2.13 4.63 8.13 3.56 4.00 3.37 6.5 5'x 11/2" 50.8 54.0 117.6 206.5 90.4 101.6 85.6 2.9 2.50 2.63 4.63 8.13 4.06 3.88 3.37 7.1 5 x 2 63.5 66.7 117.6 206.5 103.1 98.6 85.6 3.2 2.75 2.88 4.75 8.13 4.38 3.88 3.37 7.3 5" x 21/2" 69.9 73.0 120.7 206.5 111.3 98.6 85.6 3.3 2.75 2.88 4.75 8.13 4.38 3:88 3.37 7.3 5" x 76.1 mm 69.9 73.0 120.7 206.5 111.3 98.6 85.6 3.3 3.50 3.63 5.00 8.13 5.13 4.06 3.37 7.6 5" X 3" 88.9 92.1 127.0 206.5 130.3 103.1 85.6 3.4 2.00 2.13 -5.13 9.25 3.56 4.04 3.90 7.4 6" x 11/2" 50.8 54.0 130.3 235.0 90.4 102.6 99.1 3.4 2.50 2.63 5.13 9.25 4.06 4.31 3.90 7.5 6 x 2 50.8 66.7 130.3 235.0 103.1 109.5 99.1 3.4 2.75 2.88 5.13 9.25 4.38 4.18 3.90 7.5 6"x 21/2" 69.9 73.0 130.3 235.0 111.3 106.2 99.1 3.4 2.75 2.88 5.13 9.25 4.38 4.18 3.90 7.5 6" X 76.1 mm 69.9 73.0 130.3 235.0 111.3 106.2 99.1 3.4 3.50 3.63 5.50 9.25 5.13 4.37 3.90 9.5 6" x 3" 88.9 1 92.1 139.7 235.0 130.3 111.0 99.1 4.3 4.50 4.63 5.38 9.25 6.13 4.56 3.90 10.0 6" x 4" 114.3 117.5 136.7 235.0 155.7 115.8 99.1 4.5 2.75 2.88 6.25 12.50 4.38 5.12 4.90 10.2 8" x 21/2" 69.9 73.0 158.8 317.5 111.3 130.0 124.5 4.6 2.75 2.88 6.25 12.50 4.38 5.12 4.90 10.2 8" X 76.1 mm 69.9 73.0 158.8 317.5 111.3 .130.0 124.5 4.6 3.50 3.63 6.50 12.50 5.13 5.37 4.90 12.5 8" x 3" 88.9 92.1 165.1 317.5 130.3 136.4 124.5 5.7 4.50 4.63 6.38 12.50 6.13 5.56 4.90 12.5 8" x 4° 114.3 117.5 162.1 317.5 155:7 141.2 124.5 5.7 $ Proper hole preparation is required for effective sealing and performance. Check the pipe seal surface within 5/e° of the hole to be certain it is free from conditions which would affect proper gasket sealing. Remove any sharp or rough edges from the hole or upper housing contact area, which might affect assembly, proper seating of the locating collar or flow from the outlet. Check gasket grade to be certain it is suitable for the service. For crosses, ensure double outlet holes are aligned on opposite sides of the pipe. The use of threaded products other than steel pipe, such as dry pendents, etc. may not be compatible with the female threaded outlet on the Mechanical Tee. Always confirm compatibility by contacting Tyco Fire Products. /"\Note: Outlet threads conforming to BSP are available, contact Tyco Fire Products for details. 11 Figure 730 Mechanical Outlet Grooved Cross Figure 730 Mechanical Outlet Tee and Cross (Grooved) .: .__. IN wlm MOROI- Nom.Size Hole Dia.$ Dimensions Net Net Wt. Hole Max. A B C E Wt. Run x Branch Inches Inches Inches Inches Inches Inches Lbs. MM mm mm mm mm mm Kg. 5" x 2" 1.75 1.88 2.78 4.88 3.32 1.59 2.5 2" x 11/4" 63.5 66.7 117.6 206.5 103.1 85.6 3.2 5" x 21/2" 44.5 47.6 70.6 124.0 84.3 40.4 1.1 1.75 1.88 2.62 4.88 3.32 1.59 2.5 2" x 11/2" 2.75 2.88 4.75 8.13 4.38 3.37 7.3 44.5 47.6 66.5 124.01 84.3 40.4 1.1 5" x 3" 2.00 2.13 3.00 5.25 3.56 1.81 3.1 21/2" x 1114" 88.9 92.1 127.0 206.5 130.3 85.6 3.4 6" x 11/2" 50.8 54.0 76.2 133.4 90.4 46.0 1.4 2.00 2.13 3.07 5.25 3.59 1.81 3.3 2112" X 11/2" 2.50 2.63 5.13 9.25 4.06 3.90 7.5 50.8 54.0 78.0 133.4 91.2 46.0 1.5 6'x 21/2" 1.75' 1.88 3.34 6.13 3.32 2.21 3.9 3" x 11/4" 69.9 73.0 130.3 235.0 111.3 99.1 3.4 6" x 76.1 mm 44.5 47.6 84.8 155.7 84.3 56.1 1.8 3"x 11/2" 2.00 2.13 3.38 6.13 3.56 2.21 4.2 6" x 3" 50.8 54.0 85.9 155.7 90.4 56.1 1.9 2.50 2.63 3.50 6.13 4.09 2.21 4.7 3" x 2" 4.50 4.63 5.38 9.25 6.13 3.90 10.0 63.5 66.7 1 88.9 155.7 103.9 56.1 2.1 8"x 2;/2" 1.75' 1.88 3.92 7.13 3.32 2.78 5.5 4"x 11/4" 69.9 73.0 158.8 317.5 111.3 124.5 4.6 8" x 76.1 mm 44.5 47.6 99.6 181.1 84.3 70.6 2.5 2.00 2.13 4.00 7.13 3.56 2.78 5.5 4"x 11/2" 3.50 3.63 6.50 12.50 5.13 4.90 12.5 50.8 54.0 101.6 181.1 90.4 70.6 2.5 8'x 4" 2.50 2.63 4.00 7.13 4.06 2.78 6.0 4" x 2" 114.3 117.5 162.1 317.5 155.7 124.5 5.7 63.5 66.7 101.6 181.1 103.1 70.6 2.7 2.75 2.88 4.00 7.13 4.38 2.78 6.0 4"x 21/2" 69.9 73.0 101.6 181.1 111.3 70.6 2.7 2.75 2.88 4.00 7.13 4.38 2.78 6.0 4" X 76.1 mm 69.9 73.0 101.6 181.1 111.3 70.6 2.7 3.50 3.63 4.13 7.13 5.13 2.78 7.0 4'x 3" 88.9 92.1 104.9 181.1 130.3 70.6 3.2 2.00 2.13 4.63 8.13 3.56 3.37 6.5 5" x 11/2" 50.8 54.0 117.6 206.5 90.4 1 85.6 2.9 I Figure 730 Mechanical Outlet Grooved Tee Nom. Size Hole Dia. $ Dimensions Net Wt. Hole Max. A B C E Run x Branch Inches Inches Inches Inches Inches Inches Lbs. MM mm mm mm mm mm Kg. 5" x 2" 2.50 2.63 4.63 8.13 4.06 3.37 7.1 63.5 66.7 117.6 206.5 103.1 85.6 3.2 5" x 21/2" 2.75 2.88 4.75 8.13 4.38 3.37 7.3 69.9 73.0 120.7 206.5 111.3 85.6 3.3 5" x 76.1 mm 2.75 2.88 4.75 8.13 4.38 3.37 7.3 69.9 73.0 120.7 206.5 111.3 85.6 3.3 5" x 3" 3.50 3.63 5.00 8.13 5.13 3.37 7.6 88.9 92.1 127.0 206.5 130.3 85.6 3.4 6" x 11/2" 2.00 2.13 5.13 9.25 3.56 3.90 7.4 50.8 54.0 130.3 235.0 90.4 99.1 3.4 6" x 2" 2.50 2.63 5.13 9.25 4.06 3.90 7.5 50.8 66.7 130.3 235.0 103.1 99.1 3.4 6'x 21/2" 2.75 2.88 5.13 9.25 4.38 3.90 7.5 69.9 73.0 130.3 235.0 111.3 99.1 3.4 6" x 76.1 mm 2.75 2.88 5.13 9.25 4.38 3.90 7.5 69.9 73.0 130.3 235.0 111.3 99.1 3.4 6" x 3" 3.50 3.63 5.50 9.25 5.13 3.90 9.5 88.9 92.1 139.7 235.0 130.3 99.1 4.3 6'x 4" 4.50 4.63 5.38 9.25 6.13 3.90 10.0 114.3 117.5 136.7 235.0 155.7 99.1 4.5 8"x 2;/2" 2.75 2.88 6.25 12.50 4.38 4.90 10.2 69.9 73.0 158.8 317.5 111.3 124.5 4.6 8" x 76.1 mm 2.75 2.88 6.25 12.50 4.38 4.90 10.2 69.9 73.0 158.8 317.5 111.3 124.5 4.6 8"x 3" 3.50 3.63 6.50 12.50 5.13 4.90 12.5 88.9 92.1 165.1 317.5 130.3 124.5 5.7 8'x 4" 4.50 1 4.63 1 6.3T 12.501 6.13 4.90 12.5 114.3 117.5 162.1 317.5 155.7 124.5 5.7 t Proper hole preparation is required for effective sealing and performance. Check the pipe seal surface within 5/e" of the hole to be certain it is free from conditions which would affect proper gasket sealing. Remove any sharp or rough edges from the hole or upper housing contact area, which might affect assembly, proper seating of the locating collar or flow from the outlet. Check gasket grade to be certain it is suitable for the service. For crosses, ensure double outlet holes are aligned on opposite sides of the pipe. The use of threaded products other than steel pipe, such as dry pendents, etc. may not be compatible with the female threaded outlet on the Mechanical Tee. Always confirm compatibility by contacting Tyco Fire Products. Note: Outlet threads conforming to BSP are available, contact Tyco Fire Products for details. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure hat pressure ratings and performance data is not exceeded. Always read and understand the installation ��O nstructions (IH -1000). Never remove any piping component nor correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be 9.004 compatible for the specific application. Certified Company 'TCO/F/ow Control Tyco Fire Printed in U.S.A. 4-01 Products 100 SO2 til He!* USLOWCLOSE BRONZE BUTTERFLY VALVE ONE-PIECE, FULL -PORT 175 PSI FM Ism THREADED ENDS APPROVED �1� DIMENSIONS ALL DIMENSIONS -INCHES 'Pertains to 13B-SC100 only. 'Pertains to BB-SCS02 only. 'M-40 ARE DIMENSIONS USING SCHEDULE 40 PIPE M-80 ARE DIMENSIONS USING SCHEDULE 80 PIPE 'N40 IS FLOW RESISTANCE EXPRESSEDIN EQUIVALENT LENGTH OF SCHEDULE 40 PIPE 'W IS THE WRENCH MAKE-UP LENGTH FEATURES • Slow opening and closing • Quarter tum operation • Water Hammer elimination • Optional internal tamper switch (Indoor use only). - Signals disc movement - Factory or. Field installation - 10 Amp / 115 VAC -60 Hz - 0.5 Amp / 28 VDC • Grooved Ends Available in Sizes 2" and 2-1/2" MATERIALS LIST Approved by: NYC Board of Stds. & Apppgals, Cal. #996 -81 -SM (C psi 720 -83 -SA (350 8 500 psi; A A in" r BB-SC100 Sizes 1", 1-1/4", 1-1/2", 2", 2-1/2" The information presented on this sheet is correct at the time of publication. Milwaukee Valve reserves the right to change design, and/or material specifications without notice. For the most current information access www.milwaukeevalve.com. B CIW_i .CDR BB-SCS02 (Includes Switch) MILWAUKEE VALVE Valve Size DIM 1" 1-114" 1412" 2" 2-1/2" A 2.13 2.63 2.88 3.25 4.13 . B' 3.16 3.31 3.41 3.63 3.82 C 1.56 1.94 2.19 2.75 3.19 D 1.72 2.11 2.38. 3.07 3.50 JZ 4.16 4.16 4.51 4.76 4.66 K .66 .73 .73 .79 1.18 L .. .83 .90 .10 1.41 1.29 M-403 1.10 1.38 1.61 2.07 2.47 M-80' .96 1.28 1.50 1.94 2.32 N-40' 2.25 2.00 2.50 2.25 10.00 1.13 1.25 1.41 1.69 1.75 ALL DIMENSIONS -INCHES 'Pertains to 13B-SC100 only. 'Pertains to BB-SCS02 only. 'M-40 ARE DIMENSIONS USING SCHEDULE 40 PIPE M-80 ARE DIMENSIONS USING SCHEDULE 80 PIPE 'N40 IS FLOW RESISTANCE EXPRESSEDIN EQUIVALENT LENGTH OF SCHEDULE 40 PIPE 'W IS THE WRENCH MAKE-UP LENGTH FEATURES • Slow opening and closing • Quarter tum operation • Water Hammer elimination • Optional internal tamper switch (Indoor use only). - Signals disc movement - Factory or. Field installation - 10 Amp / 115 VAC -60 Hz - 0.5 Amp / 28 VDC • Grooved Ends Available in Sizes 2" and 2-1/2" MATERIALS LIST Approved by: NYC Board of Stds. & Apppgals, Cal. #996 -81 -SM (C psi 720 -83 -SA (350 8 500 psi; A A in" r BB-SC100 Sizes 1", 1-1/4", 1-1/2", 2", 2-1/2" The information presented on this sheet is correct at the time of publication. Milwaukee Valve reserves the right to change design, and/or material specifications without notice. For the most current information access www.milwaukeevalve.com. B CIW_i .CDR BB-SCS02 (Includes Switch) MILWAUKEE VALVE 101 tqcoFire & Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 CENTRAL Customer ice/Sales: Tel: (215) 362-0700 / (800) 523-6512 Fax: (215) 362-5385 Series LFII Residential Concealed Pendent Sprinklers, Flat Plate 4.2 K -factor General Description The Series LFII (TY2596) Residential Concealed Pendent Sprinklers are decorative, fast response, fusible sol- der sprinklers designed for use in resi- dential occupancies such as homes, apartments, dormitories, and hotels. The cover plate assembly conceals the sprinkler operating components above the ceiling. The flat profile of the cover plate provides the optimum aestheti- cally appealing sprinkler design. In ad- dition, the concealed design of the Se- ries LFII (TY2596) provides 1/2 inch (12,7 mm) vertical adjustment. This adjustment reduces the accuracy to which the fixed pipe drops to the sprin- klers must be cut to help assure a perfect fit installation. The Series LFII are to be used in wet pipe residential sprinkler systems for one- and two-family dwellings and mo- bile homes per NFPA 13D; wet pipe residential sprinkler systems for resi- dential occupancies up to and includ- ing four stories in height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occu- pancy per NFPA 13. The Series LFII (TY2596) has a 4.2 (60,5) K -factor that provides the re- quired residential flow rates at reduced pressures, enabling smaller pipe sizes and water supply requirements. The Series LFII (TY2596) has been designed with heat sensitivity and water distribution characteristics proven to help in the control of residen- tial fires and to improve the chance for occupants to escape or be evacuated. The Series LFII (TY2596) Residential Concealed Pendent Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed for installation, and then it can be replaced to help protect the sprinkler while the ceiling is being in - Page 1 of 4 stalled or finished. The tip of the Pro- tective Cap can also be used to mark the center of the ceiling hole into plas- ter board, ceiling tiles, etc. by gently pushing the ceiling product against the Protective Cap. When the ceiling in- stallation is complete the Protective Cap is removed and the Cover Plate Assembly installed. WARNINGS The Series LFII (TY2596) Residential Concealed Pendent Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities ha v- ing jurisdiction. Failure to do so may impair the integrity of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Sprinkler/Model Identification Number SIN TY2596 Technical Data Approvals: UL and C -UL Listed. Maximum Working Pressure: 175 psi (12,1 bar) Discharge Coefficient: K = 4.2 GPM/psis/2 (60,5 LPM/bars/2) Temperature Rating: 160°F/71 °C Sprinkler with 135°F/57°C Cover Plate JANUARY, 2003 Vertical Adjustment: 1/4 inch (6,4 mm) Finishes: Cover Plate: Flat White, Bright White, Chrome, or Custom Physical Characteristics: Body . . . . .. .. . . . . . . Brass Cap . . . . . .. .. . . . . . Bronze Saddle . . .. . . . . . . Brass Sealing Assembly . . Beryllium Nickel w/ Teflont Soldered Link Halves . . . . . Nickel Lever . . . . . . . . . . . Bronze Compression Screw . .. . . Brass Deflector .. .. . . . . Copper Guide Pin Housing . Bronze Guide Pins . . . .. . Stainless Steel Support Cup .. . . . . . .. . Steel Cover Plate . . . . . . . . . Copper Retainer . . . . . Brass Cover Plate Ejection Spring . . . . . . . . . . . . . Stainless Steel tDuPont Registered Trademark TFP440 Page 2 of 4 TFP440 (a) For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K -factor. Refer to Hydraulic Design Criteria Section for details. TABLE A NFPA 13D AND NFPA 13R HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY2596) RESIDENTIAL CONCEALED PENDENT SPRINKLER Operation When exposed to heat from a fire, the Cover Plate, which is normally sol- dered to the Support Cup at three points, falls away to expose the Sprin- kler Assembly. At this point the Deflec- tor supported by the Arms drops down to its operated position. The fusible link of the Sprinkler Assembly is com- prised of two link halves that are sol- dered together with a thin layer of sol- der. When the rated temperature is reached, the solder melts and the two link halves separate allowing the sprin- kler to activate and flow water. Design Criteria The Series LFII (TY2596) Residential Concealed Pendent Sprinklers are UL and C -UL Listed for installation in ac- cordance with the following criteria. NOTE When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that maybe accept- able to the Authority Having Jurisdic- tion. System Type. Only wet pipe systems may be utilized. Hydraulic Design. The minimum re- quired sprinkler flow rate for systems designed to NFPA 13D or NFPA 13R are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprin- kler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as speci- fied in NFPA 13D or NFPA 13R. For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: • The flow rates given in Table A for NFPA 13D and 13R as a function of temperature rating and the maxi- mum allowable coverage area. • A minimum discharge of 0.1 gpm/sq. ft. over the "design area" comprised of the four most hydraulically de- manding sprinklers for the actual coverage areas being protected by the four sprinklers. Obstruction To Water Distribution. Locations of sprinklers are to be in accordance with the obstruction rules of NFPA 13 for residential sprinklers. Operational Sensitivity. The sprin- klers are to be installed relative to the ceiling mounting surface as shown in Figure 3. Sprinkler Spacing. The minimum spacing between sprinklers is 8 feet (2,4 m). The maximum spacing be- tween sprinklers cannot exceed the length of the coverage area (Ref. Table A) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). Installation The Series LFII (TY2596) must be in- stalled in accordance with the follow- ing instructions: NOTES Damage to the fusible Link Assembly during installation can be avoided by handling the sprinkler by the frame arms only (i.e., do not apply pressure to the fusible link Assembly). A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon 0 Minimum Flow (b) and Minimum Flow N and Minimum Flow (b) and Maximum Maximum Residual Pressure Residual Pressure Residual Pressure Coverage Spacing For Horizontal Ceiling For Sloped Ceiling For Sloped Ceiling Area (a) Ft. (Max. 2 Inch Rise (Greater Than 2 Inch (Greater Than 4 Inch Ft. x Ft. (m) for 12 Inch Run) Rise Up To Rise Up To (m x m) Max. 4 Inch Rise Max. 8 Inch Rise for 12 Inch Run) for 12 Inch Run) 160°Ff71°C 160'F171 *C 160°Ff71°C Sprinkler Sprinkler Sprinkler 12 x 12 12 13 GPM (49,2 LPM) 18 GPM (68,1 LPM) 18 GPM (68,1 LPM) (3,7 x 3,7) (3,7) 9.6 psi (0,66 bar) 18.4 psi (1,27 bar) 18.4 psi (1,27 bar) 14 x 14 14 14 GPM (53,0 LPM) 18 GPM (68,1 LPM) 18 GPM (68,1 LPM) (4,3 x 4,3) (4,3) 11.1 psi (0,77 bar) 18.4 psi (1,27 bar) 18.4 psi (1,27 bar) 16 x 16 16 16 GPM (60,6 LPM) 18 GPM (68,1 LPM) 18 GPM (68,1 LPM) (4,9 x 4,9) (4,9) 14.5 psi (1,00 bar) 18.4 psi (1,27 bar) 18.4 psi (1,27 bar) 18 x 18 18 20 GPM (75,7 LPM) 20 GPM (75,7 LPM) WA (5,5 x 5,5) (5,5) 22.7 psi (1,57 bar) 22.7 psi (1,57 bar) 20 x 20 20 24 GPM (90,8 LPM) 26 GPM (98,4 LPM) WA (6,1 x 6,1) (6,1) 32.7 psi (2,25 bar) 1 38.3 psi (2,64 bar) TFP440 (a) For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K -factor. Refer to Hydraulic Design Criteria Section for details. TABLE A NFPA 13D AND NFPA 13R HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII (TY2596) RESIDENTIAL CONCEALED PENDENT SPRINKLER Operation When exposed to heat from a fire, the Cover Plate, which is normally sol- dered to the Support Cup at three points, falls away to expose the Sprin- kler Assembly. At this point the Deflec- tor supported by the Arms drops down to its operated position. The fusible link of the Sprinkler Assembly is com- prised of two link halves that are sol- dered together with a thin layer of sol- der. When the rated temperature is reached, the solder melts and the two link halves separate allowing the sprin- kler to activate and flow water. Design Criteria The Series LFII (TY2596) Residential Concealed Pendent Sprinklers are UL and C -UL Listed for installation in ac- cordance with the following criteria. NOTE When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufacturer's recommendations that maybe accept- able to the Authority Having Jurisdic- tion. System Type. Only wet pipe systems may be utilized. Hydraulic Design. The minimum re- quired sprinkler flow rate for systems designed to NFPA 13D or NFPA 13R are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprin- kler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as speci- fied in NFPA 13D or NFPA 13R. For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: • The flow rates given in Table A for NFPA 13D and 13R as a function of temperature rating and the maxi- mum allowable coverage area. • A minimum discharge of 0.1 gpm/sq. ft. over the "design area" comprised of the four most hydraulically de- manding sprinklers for the actual coverage areas being protected by the four sprinklers. Obstruction To Water Distribution. Locations of sprinklers are to be in accordance with the obstruction rules of NFPA 13 for residential sprinklers. Operational Sensitivity. The sprin- klers are to be installed relative to the ceiling mounting surface as shown in Figure 3. Sprinkler Spacing. The minimum spacing between sprinklers is 8 feet (2,4 m). The maximum spacing be- tween sprinklers cannot exceed the length of the coverage area (Ref. Table A) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). Installation The Series LFII (TY2596) must be in- stalled in accordance with the follow- ing instructions: NOTES Damage to the fusible Link Assembly during installation can be avoided by handling the sprinkler by the frame arms only (i.e., do not apply pressure to the fusible link Assembly). A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon 0 D THREADINTO SUPPORT CUP UNTIL MOUNTING SURFACE IS FLUSH WITH CEILING SOLDER TAB SEALING ASSEMBLY SPRINKLER WRENCHING AREA COMPRESSION SCREW LEVER TFP440 I I I I I I I I ELEMENT I I I I I I I BODY DEFLECTOR (1/2" NPT) _ (OPERATED CAP POSITION) SADDLE SUPPORT CUP WITH ' RETAINER ROLL FORMED WITH THREAD THREADS i DIMPLES GUIDE PIN GUIDE PIN HOUSING DEFLECTOR - D THREADINTO SUPPORT CUP UNTIL MOUNTING SURFACE IS FLUSH WITH CEILING SOLDER TAB SEALING ASSEMBLY SPRINKLER WRENCHING AREA COMPRESSION SCREW LEVER COVER PLATE/RETAINER ASSFMRLY FIGURE 1 SERIES LFII (TY2596) RESIDENTIAL CONCEALED PENDENT SPRINKLER 2-1/2" DIA. (63,5 mm) 1/2" (12,7 mm) FACE OF \ 1/2" THREADED SPRINKLER NPT ADJUSTMENT FITTING 1-7/8"t1/8" (47,6 mm _ 1/8" GAP t3,2 mm) _ (3,2 mm) _ COVER- SPRINKLER -MOUNTING RETAINER SUPPORTCUP 3/16 SURFACE ASSEMBLY ASSEMBLY (4,8 mm) 3-3/16" DIA. (81,0 mm) TIP EJECTION SPRING COVER PLATE Page 3of4 Plate by under- or over -tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be installed in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, and using the W -Type 18 Wrench shown in Figure 2, install and tighten the Sprinkler/Sup- port Cup Assembly into the fitting. The W -Type 18 Wrench will accept a 1/2 inch ratchet drive. Step 4. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Protec- tive Cap helps prevent damage to the Deflector and Arms during ceiling in- stallation and/or during application of the finish coating of the ceiling. lt,may also be used to locate the center of the WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WREN HIN AREA FIGURE 2 W- TYPE 18 SPRINKLER WRENCH SPRINKLER - SUPPORT rI IP ASSEMBI OPERATE SPRINKLE COVER PLATE RETAINE I- 7/8' (22,2 n 1-1/8"(28,6 DISPOSABLE PROTECTIVE CAP DEFLECTOR IN OPERATED POSITION FIGURE 3 SERIES LFII (TY2596) RESIDENTIAL CONCEALED PENDENT SPRINKLER INSTALLATION DIMENSIONS / PROTECTIVE CAP /ACTIVATED DEFLECTOR SOLDER LINK I I I I I I I I ELEMENT I I I I I I I I I I I [_rJ L I DEFLECTOR (OPERATED " POSITION) SPRINKLER/SUPPORT CUP ASSEMBLY I RETAINER WITH THREAD i DIMPLES COVER PLATE/RETAINER ASSFMRLY FIGURE 1 SERIES LFII (TY2596) RESIDENTIAL CONCEALED PENDENT SPRINKLER 2-1/2" DIA. (63,5 mm) 1/2" (12,7 mm) FACE OF \ 1/2" THREADED SPRINKLER NPT ADJUSTMENT FITTING 1-7/8"t1/8" (47,6 mm _ 1/8" GAP t3,2 mm) _ (3,2 mm) _ COVER- SPRINKLER -MOUNTING RETAINER SUPPORTCUP 3/16 SURFACE ASSEMBLY ASSEMBLY (4,8 mm) 3-3/16" DIA. (81,0 mm) TIP EJECTION SPRING COVER PLATE Page 3of4 Plate by under- or over -tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be installed in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, and using the W -Type 18 Wrench shown in Figure 2, install and tighten the Sprinkler/Sup- port Cup Assembly into the fitting. The W -Type 18 Wrench will accept a 1/2 inch ratchet drive. Step 4. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Protec- tive Cap helps prevent damage to the Deflector and Arms during ceiling in- stallation and/or during application of the finish coating of the ceiling. lt,may also be used to locate the center of the WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WREN HIN AREA FIGURE 2 W- TYPE 18 SPRINKLER WRENCH SPRINKLER - SUPPORT rI IP ASSEMBI OPERATE SPRINKLE COVER PLATE RETAINE I- 7/8' (22,2 n 1-1/8"(28,6 DISPOSABLE PROTECTIVE CAP DEFLECTOR IN OPERATED POSITION FIGURE 3 SERIES LFII (TY2596) RESIDENTIAL CONCEALED PENDENT SPRINKLER INSTALLATION DIMENSIONS / PROTECTIVE CAP /ACTIVATED DEFLECTOR Page 4 of 4 clearance hole by gently pushing the ping, striking, wrench twist/slippage, ceiling material against the center or the like, must be replaced. point of the Cap. The owner is res onsible for the in- NOTE As long as the protective Cap remains in place, the system is considered to be "Out Of Service". Step S. After the ceiling has been com- pleted with the 2-1/2 inch (63 mm) diameter clearance hole and in prepa- ration for installing the Cover Plate As- sembly, remove and discard the Pro- tective Cap, and verify that the Deflector moves up and down freely. If the Sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire Sprin- kler assembly. Do not attempt to mod- ify or repair a damaged sprinkler. Step 6. Screw on the Cover Plate As- sembly until its flange comes in con- tact with the ceiling. Do not continue to screw on the Cover Plate Assembly such that it lifts a ceil- ing panel out of its normal position. If the Cover Plate Assembly cannot be engaged with the Mounting Cup or the Cover Plate Assembly cannot be en- gaged sufficiently to contact the ceil- ing, the Sprinkler Fitting must be repo- sitioned. Care and Maintenance The Series LFII (TY2596) must be maintained and serviced in accord- ance with the following instructions: NOTES Absence of an Escutcheon Plate may delay the sprinkler operation in a fire situation. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection sys- tem must be obtained from the proper authorities and all personnel who may be affected by this action must be no- tified. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied or over heated sprinklers must be replaced. Care must be exercised to avoid dam- age - before, during, and after instal- lation. Sprinklers damaged by drop - p spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. NOTE The owner must assure that the sprin- klers are not used for hanging of any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster, otherwise, non- operation in the event of a fire or inad- vertent operation may result. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR TFP440 UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE 1N LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR OF MERCHANTABILITY AND El NESS FOR A PARTICULAR PUR- POSE, Ordering Procedure When placing an order, indicate the full product name. Contact your local dis- tributor for availability.. Sprinkler Assembly: Series LFII (TY2596), K=4.2, Residen- tial Concealed Pendent Sprinkler with- out Cover Plate Assembly, P/N 51-122-1-160. Cover Plate Assembly: Cover Plate Assembly having a (spec- ify) finish for the Series LFII (TY2596), K=4.2, Residential Concealed Pen- dent Sprinkler, P/N (specify). Chrome .................. P/N 56-122-9-135 Off White ................. P/N 56-122-0-135 Bright White ............... P/N 56-122-4-135 Flat White ................. P/N 56-122-5-135 Custom .................. P/N 56-122-X-135 Sprinkler Wrench: Specify: W -Type 18 Sprinkler Wrench, P/N 56-000-1-265. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 IN • •1-0-Vatl WL 4.2, 5.6 & 8.0 K -factor Quick Response Standard Coverage Upright, Pendent & Rec. Pendent Glass Bulb Automatic Sprinkler Tyco Fire Products -- www.centraisprinkler.com 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA Customer Service/Sales: Tel: (215) 362-0700 / Fax: (215) 362-5385 Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 General .� Description The Central Model BV -QR, 4.2 & 5.6 K -factor (7/16" & 1/2" orifice) & Model BVLO-QR, 8.0 K -factor (17/32" orifice), Upright, Pendent, and Rec. Pendent Sprinklers are quick response - standard coverage, decorative glass bulb type spray sprinklers designed for use in light & ordinary hazard, commercial occupancies such as banks, hotels, shopping malls etc. The recessed version of the Central Model BV -QR, intended for use in areas with a finished ceiling, uses a two-piece Model BV Res/QR Recessed Escutcheon (Vented or Unvented). The Model BV Res/QR Recessed Escutcheon provides up to 3/8 inch (9,5 mm) of total adjustment from the flush pendent position. The recessed version of the Central Model BVLO-QR, also intended for use in areas with a finished ceiling, uses a two-piece Model ELO Recessed Escutcheon. The Model ELO Recessed Escutcheon provides up to 314 inch (19,1 mm) of total adjustment from the flush pendent position. The adjustment provided by these Recessed Escutcheons reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut These sprinklers are available with a polyester coating that may be utilized to extend the fife of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmospheres. Although polyester coated sprinklers have passed the standard corrosion tests of the applicable approval agencies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of this corrosion resistant coating for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. Operation: The glass bulb contains a fluid which expands when exposed to heat When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, which then allows the sprinkler to activate & flow water. WARNING The Model BV -QR & BVLO-QR Upright Pendent & Rec. Pendent Sprinlders described herein must be installed and maintained in compliance with chis document as well as with the applicable standards of the National Fire Protection Association, in addtiion to the standards of any other authorities having jurisdiction. Failure to do so may impair the integrity of these devices. The owner is responsible for maintaining their fire protection system and devR)es in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Figure 1 - Cross Section Model BVLO-QR, Upright Sprinkler COMPRESSION DEFLECTOR SCREW / GLASS BULB OPERATING ELEMENT \ SPRINKLER FRAME BUTTON GASKETED SPRING ASSEMBLY PLATE (BELLEVILLE SEAL) CENTRAL Standard Spray Upright, Pendent & Rec. Pendent Sprinklers No. 1-7.0 Figure 2 - Model BV -QR, Upright, Pendent & Rec. Pendent Sprinkler 1/2" NPT (27,0 mm) SPRINKLER FINISH & STYLE Temperature Rating Bulb ColorCode 2-1116" lV2llN3� FACE OF (52,4 mm) WRENCH 2-1/16" Recessed FLAT (52,4 CENTRAL mm) ` 112" NPT COUPLING 1-1116" � / 1,2,3**,4 (27,0 mm) Red ELEVATION VIEW SPRINKLER FINISH & STYLE Temperature Rating Bulb ColorCode i FACE OF Polyester Coated . Recessed REDUCING Orange 1,2,3,4 COUPLING 1,2,3*,4 1,2,3**,4 3/8" (9,5 mm) Red 1,2,3,4 1,2,3,4 1,2,3*,4 Min. 175°F/79°C Yellow 1,2,3,4 1,2,3,4 - 314" (19,1 mm) 200117/931C Green 1,2,3,4 1,2,3,4 1,2,3*,4 Max. 250117/1211C Blue 1H2J1N3� 1,2,3,4 1,2,3*,4 \ OUTER FINISHED ESCUTCHEON CEILING LINE RING MODEL BV Res1QR RECESSED RECESSED SUPPORT CUP 2"(50,8 mm) Min. ESCUTCHEON 2-1/4"(57,2 mm) Max. 2-7/8"(73,0 mm Table 1 - Laboratory Listings and Approvals, Model BV -QR 1. Listed by Underwriters Laboratories, Inc. - (K = 4.2 & 5.6) 2. Listed by Underwriters' Laboratories of Canada. - (K = 4.2 & 5.6) 3. Approved by Factory Mutual Research Corporation. - (K = 5.6) 4. Approved by the City of New York under MEA 466-92-E Vol. III. - (K = 4.2 & 5.6) * Pendent Only. ** Only Approved with the Series BV Res/QR (Vented) Recessed Escutcheon Assy Technical Data Sprinkler Identification Number SIN C2201- BV -QR Pend (K=4.2) SIN C2101- BV -QR UP (K=4.2) SIN C3201 - BV -QR Pend (K=5.6) SIN C3101- BV -QR UP (K=5.6) SIN C4201- BVLO-QR Pend (K=8.0) SIN C4101- BVLO-QR UP (K=8.0) Approvals UL, ULC & C -UL Listed. FM & NYC Approved (Refer to Table 1 - 2. The approvals apply only to the service conditions indicated in the Design Criteria Section) Maximum Working Pressure 175 psi (12,1 bar) 250 psi (17,3 bar) UL & ULC (K=5.6) Pipe Thread Connection 1/2 inch NPT - (K=4.2 & 5.6) 3/4 inch NPT - (K=8.0) Discharge Coefficient K = 4.2 GPM/psi1/2 (60,5 LPM/bar'n) K = 5.6 GPM/psi'rz (80,6 LPM/bar'rz) K = 8.0 GPM/psi'n (115,2 LPM/bar72) Temperature Ratings 135°F/571C, 1550F/680C, 175°F/79°C 200017/930C, 250117/121 °C Finishes Sprinkler. White Polyester, Chrome Plated, or Natural Brass Rec. Escutcheon: White Coated, Chrome Plated, or Brass Plated Corrosion Resistant Coatings Sprinkler. White Polyester (UL only) Head Guard & Water Shield: G-3 (Guard) - (K=5.6) Up & Pend. WSG-3 (Guard & Shield) - (K=5.6) Up WS -3 (Shield) - (K=5.6) Pendent (See Data Sheet 3-13.0 for details) Physical Characteristics The Model BV -QR & BVLO-QR Upright, Pendent & Rec. Pendent Sprinklers utilize a dezincitication resistant (DZR) bronze frame and a 3 mm bulb. The two-piece button assembly is brass and copper. The sprinkler frame orifice is sealed with a gasketed spring plate (Belleville Seal) consisting of a beryllium nickel disc spring that is sealed on both its inside and outside edges with a TeflonTm gasket. The compression screw is bronze, & the deflector is brass. SPRINKLER FINISH & STYLE Temperature Rating Bulb ColorCode Natural Brass Chrome Plated Polyester Coated . Recessed 1351F/570C Orange 1,2,3,4 1,2,3,4 1,2,3*,4 1,2,3**,4 1551F/680C Red 1,2,3,4 1,2,3,4 1,2,3*,4 1,2,3**,4 175°F/79°C Yellow 1,2,3,4 1,2,3,4 1,2,3*,4 1,2,3**,4 200117/931C Green 1,2,3,4 1,2,3,4 1,2,3*,4 1,2,3**,4 250117/1211C Blue 1,2,3,4 1,2,3,4 1,2,3*,4 ---- 1. Listed by Underwriters Laboratories, Inc. - (K = 4.2 & 5.6) 2. Listed by Underwriters' Laboratories of Canada. - (K = 4.2 & 5.6) 3. Approved by Factory Mutual Research Corporation. - (K = 5.6) 4. Approved by the City of New York under MEA 466-92-E Vol. III. - (K = 4.2 & 5.6) * Pendent Only. ** Only Approved with the Series BV Res/QR (Vented) Recessed Escutcheon Assy Technical Data Sprinkler Identification Number SIN C2201- BV -QR Pend (K=4.2) SIN C2101- BV -QR UP (K=4.2) SIN C3201 - BV -QR Pend (K=5.6) SIN C3101- BV -QR UP (K=5.6) SIN C4201- BVLO-QR Pend (K=8.0) SIN C4101- BVLO-QR UP (K=8.0) Approvals UL, ULC & C -UL Listed. FM & NYC Approved (Refer to Table 1 - 2. The approvals apply only to the service conditions indicated in the Design Criteria Section) Maximum Working Pressure 175 psi (12,1 bar) 250 psi (17,3 bar) UL & ULC (K=5.6) Pipe Thread Connection 1/2 inch NPT - (K=4.2 & 5.6) 3/4 inch NPT - (K=8.0) Discharge Coefficient K = 4.2 GPM/psi1/2 (60,5 LPM/bar'n) K = 5.6 GPM/psi'rz (80,6 LPM/bar'rz) K = 8.0 GPM/psi'n (115,2 LPM/bar72) Temperature Ratings 135°F/571C, 1550F/680C, 175°F/79°C 200017/930C, 250117/121 °C Finishes Sprinkler. White Polyester, Chrome Plated, or Natural Brass Rec. Escutcheon: White Coated, Chrome Plated, or Brass Plated Corrosion Resistant Coatings Sprinkler. White Polyester (UL only) Head Guard & Water Shield: G-3 (Guard) - (K=5.6) Up & Pend. WSG-3 (Guard & Shield) - (K=5.6) Up WS -3 (Shield) - (K=5.6) Pendent (See Data Sheet 3-13.0 for details) Physical Characteristics The Model BV -QR & BVLO-QR Upright, Pendent & Rec. Pendent Sprinklers utilize a dezincitication resistant (DZR) bronze frame and a 3 mm bulb. The two-piece button assembly is brass and copper. The sprinkler frame orifice is sealed with a gasketed spring plate (Belleville Seal) consisting of a beryllium nickel disc spring that is sealed on both its inside and outside edges with a TeflonTm gasket. The compression screw is bronze, & the deflector is brass. Q 11Design Criteria The Model BV -QR & BVLO-QR Upright, Pendent & Rec. Pendent Sprinklers are Quids Response, Standard Coverage, Spray Sprinklers intended for fire protection systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency. The 4.2 K -Factor, Model BV -QR Sprinklers (Ref. Table 1) are UL & ULC listed and NYC Approved for use in accordance with current NFPA standards. The 5.6 K -Factor, Model BV -QR Sprinklers (Ref. Table 1) are UL & ULC listed and NYC Approved for use in accordance with current NFPA standards, and FM Approved for use in accordance with the FM Loss Prevention Data Sheets. The 8.0 K -Factor, Model BVLO-QR Sprinklers (Ref. Table 2) are UL & C -UL listed for use in accordance with current NFPA standards, and FM Approved for use in accordance with the FM Loss Prevention Data Sheets. The Model BV -QR & BVLO-QR Sprinklers can be used with any metalic flush or extended escutcheon, provided the maximum ceiling to top of sprinkler deflector dimension specified in NFPA 13 is maintained. For recessed applications, only the Model BV Res/QR Vented or Unvented, (for 4.2 & 5.6 K factor sprinkers) and ELO (for 8.0 K -factor sprinklers) Recessed Escutcheon Assemblies may be used. NOTE Inquiries concerning the appropriateness of polyester coated sprinklers for a given corrosive environment should be submitted to the attention of the Technical Services Department Polyester coated sprinklers are not suitable for use in open Sprinkler applications. K3 Installation The Model BV -QR & BVLO-QR Sprinklers must be installed in accordance with the following instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 11 250°F/121 °C eating. {� f� A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 &ft. (9,5 to 19,0 Nm). A maximum of (Continued on Page 4) Figure 3 - Model BVLO-QR, Upright, Pendent & Rec. Pendent Sprinkler 1-3/8 W314- NPT 1(35,0 mm)� 1V211N3� 2 f (54,,00 m mm)(( 11 WRENCH JI FLAT (544,,00 m mm) NiRAL 3/4" NPT L 1-3/16" (30,2 mm) ELEVATION VIEW 1V2f1N30 OUTER RING FACE OF REDUCING COUPLING 3/8" (9,5 mm) Min. 1-1/8"(28,6 mm) \ Max. FINISHED CEILING LINE / RECESSED SUPPORT CUP WRENCH FLAT 2-1/4" (57,2 mm) Min. \ MODEL ELO RECESSED ESCUTCHEON Bulb Color Code 2-3/4"(69,9 mm) Max. Chrome Plated Polyester Coated 3-1/4'(82,6 mm 135°17/571C Table 2 - Laboratory Listings and Approvals, Model BVLO-QR 1. Listed by Underwriters Laboratories, Inc. 2. Listed by Underwriters Laboratories for use in Canada (C -UL). 3. Approved by Factory Mutual Research Corporation. SPRINKLER FINISH & STYLE Temperature Rating Bulb Color Code Natural Brass Chrome Plated Polyester Coated Recessed 135°17/571C Orange 1,2,3 1,2,3 1,2,3 1,2,3 155117/680C Red 1,2,3 1,2,3 1,2,3 1,2,3 1751Ff791C Yellow 1,2,3 1,2,3 1,2,3 1,2,3 200117/931C Green 1,2,3 1,2,3 1,2,3 1,2,3 250017/121 IC Blue 1,2,3 1,2,3 1,2,3 ---- 1. Listed by Underwriters Laboratories, Inc. 2. Listed by Underwriters Laboratories for use in Canada (C -UL). 3. Approved by Factory Mutual Research Corporation. 13 Installation (Cont.) 21 ft. lbs. (28, 5 Nm) of torque is to be used to install 1/2 inch NPT sprinklers. A leak fight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft. lbs. (13,4 to 26,8 Nm). A maximum of 30 ff.lbs. (40,7 Nm) of torque is to be used to install 3/4 inch NPT sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leakage or impair- ment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under- or over -lightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. Upright sprinklers must be installed only in the upright position & pendent sprinklers must be installed only in the pendent position. The deflector is to be parallel to the ceiling, roof, or mounting surface, as applicable. Step 2. After installing the BV Res/QR or ELO support cup (or other escutcheon, as applicable) over the sprinkler pipe threads & with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinklerfitting. Step 3. Wrench tighten the sprinkler using only the following wrenches: BV -QR Up/Pend - Comb. Wrench (1106) BV -QR Rec. Pend - BV Wrench (1099) BVLO-QR Up & Pend - W -Type 3 (1073) BVLO-QR Rec. Pend - ELO Offset (1093) Wrenches are to be applied to the sprinkler wrench flats (Ref. Fig 2 & 3) only. Step 4. For applications using the BV -QR Rec. Pendent Sprinklers, a Protective Cap is available which helps to prevent damage to the sprinkler during ceiling installation or during application of the finish coating of the ceiling. Place the Protective Cap over the Recessed Support Cup and push it upwards until it bottoms out against the sprinkler deflector. NOTE As long as the Protective Cap remains in place, the system is considered "Out of Service. " Step S. After the ceiling has been completed, remove and discard the Protective Cap. If the sprinkler has been damaged, replace the entire sprinkler assembly. Do not attempt to modify or repair a damaged sprinkler. Step 6. Push the outer ring of the Recessed Escutcheon over the Recessed Support Cup. Do not continue to push on the Recessed Escutcheon such that it lifts a ceiling panel out of its normal position. If the Outer Recessed Escutcheon Ring cannot be engaged with the Recessed Support Cup or the Outer Recessed Escutcheon Ring cannot be engaged sufficiently to contact the ceiling, the sprinkler fitting must be repositioned. fw0 Flow Control Tyco Fire l Products ]Care & Maintenance The Model BV -QR & BVLO-QR Sprinklers must be maintained and serviced in accordance with the following instructions. NOTES Absence ofan escutcheon which is used to cover a clearance hole, may delay the time to operafion in a fire situation. Before dosing a fire protection system main control valve for maintenance work on the fire protection system it controls, permission to shut down the affected fire protection systems must be obtained from the proper authorities. All personnel who may be affected by this action must be notified. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be shipped or stored where their tempera- tures will exceed 100°F/38°C and they must never be painted, plated, coated or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a doth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage - before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installation Section). Frequent visual inspections are recom- mended to be initially performed for polyester coated sprinklers installed in corrosive environments, after the installation has been completed, to verify the integrity of the polyester coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of inspecting from the floor level, a random sampling of close-up visual inspections should be made, so as to better determine the exact sprinkler condition and the long term integrity of the polyester coating, as it may be -affected by the corrosive condi- tions present. The owner is responsible for the inspeo- tion, testing, and maintenance of their fire protection system and devices in complk ance with this document, as well as with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The installing contractor or sprinkler manufac- turer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccu- rate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSI- BILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PROD- UCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OFANYAND ALL OTHER WARRANTIES EXPRESS OR IMPLIED. INCLUDING WARRANTIES OF MERCHANTABILITYAND FITNESS FOR A PAR77CULAR PURPOSE. Ordering Information Ordering Information: When placing an order, indicate the full product name. Please specify the quantity, model, style, orifice size, temperature rating, type of finish or coating, and sprinkler wrench. Refer to price list for complete listing of Part Numbers. Teflon is a trademark of the DuPont Corp Printed in U.S.A. 5-01 O 0 EO 101 tqCLPFire & Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 CENTRAL Customer ice/Sales: Tel: (215) 362-0700 / (800) 523-6512 Fax: (215) 362-5385 ,Series RFII — 5.6 K -factor "Royal Flush 11" Pendent Concealed Sprinklers Quick & Standard Response, Standard Coverage General Description The Series RFII Quick Response (3 mm bulb) & Standard Response (5 mm bulb), 5.6 K -Factor, "Royal Flush II" Concealed Pendent Sprinklers are decorative sprinklers featuring a flat cover plate designed to conceal the sprinkler. It is the best choice for archi- tecturally sensitive areas such as hotel lobbies, office buildings, churches, and restaurants. Each unit includes a Cover Plate As- sembly that conceals the sprinkler op- erating components above the ceiling. The separable two-piece design of the Cover Plate and Support Cup Assem- blies allows installation of the sprin- klers and pressure testing of the fire protection system prior to installation of a suspended ceiling or application of the finish coating to a fixed ceiling. They also permit removal of sus- pended ceiling panels for access to building service equipment without having to first shut down the fire pro- tection system and remove sprinklers. Also, the separable two-piece design of the the Sprinkler provides for 1/2 inch (12,7 mm) of vertical adjustment, to reduce the accuracy to which the length of fixed pipe drops to the sprin- klers must be cut. The Series RFII Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed for installation, and then it can be replaced to help protect" the sprinkler while the ceiling is being in- stalled or finished. The tip of the Pro- tective Cap can also be used to mark the center of the ceiling hole into plas- ter board, ceiling tiles, etc. by gently pushing the ceiling product against the Protective Cap. When the ceiling in- stallation is complete the Protective Cap is removed and the Cover Plate Assembly installed. As an option, the Series RFII Standard Response (5 mm bulb) "Royal Flush II" Page 1 of 4 Concealed Pendent Sprinklers may be fitted with a silicone Air and Dust Seal (Ref. Fig. 5). The Air and Dust Seal is intended for sensitive areas where it is desirable to stop air and dust travel through the cover plate from the area above the ceiling. WARNINGS The Series RFII Concealed Pendent Sprinklers described herein must be installed and maintained in compli- ance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the integ- rity of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or "sprinkler manufacturer should be contacted relative to any questions. Model/Sprinkler Identification Numbers TY3551 (5mm bulb) & TY3531 (3 mm bulb): maximum 175 psi (12,1 bar) by UL, C -UL, and FM. NYC under MEA 353-01-E. TY3504 (5 mm bulb) & TY3505 (3 mm bulb): maximum 250 psi (17,3 bar) by UL and C -UL, and maximum 175 psi (12,1 bar) by FM. NYC under MEA 353-01-E. Technical Data Approvals for Series RFII UL and C -UL Listed. FM Approved. (The approvals apply only to the serv- ice conditions indicated in the Design Criteria section and maximum pres- sure ratings indicated in the JANUARY, 2003 Model/Sprinkler Identification Num- bers section.) Approvals for Air & Dust Seal (Part #10908100) UL and C -UL Listed for use with the RFII (TY3551 & TY3504) Standard Re- sponse Concealed Sprinkler. Temperature Ratings 155F/68C Sprinkler - 135F/57C Plate 200F/93C Sprinkler - 165F/74C Plate Discharge Coefficient K = 5.6 GPM/psis/2 (80,6 LPM/barl/2) Adjustment 1/2 inch (12,7 mm) Finishes Cover Plate: Chrome Plated, Brass Plated, or White Painted (Custom paint matches and colors other than white are available on request.) Physical Characteristics Frame . .. . . .. Bronze Support Cup .. Chrome Plated Steel Guide Pins . . . . . . Stainless Steel Deflector . . . . . . . . Bronze Compression Screw ...... Brass Bulb . . . . . . . . . . . . . . Glass Cap . . . . . . Bronze or Copper Sealing Assembly . . Beryllium Nickel wfTeflon* Cover Plate . . . . . . . . . . Brass Retainer .. . . . Brass Ejection Spring . . . Stainless Steel Patents U.S.A. Patent No. 4,014,388 may be applicable to the Air and Dust Seal. TFP181 Page 2 of 4 Operation When exposed to heat from a fire, the Cover Plate, which is normally sol- dered to the Retainer at three points, falls away to expose the Sprinkler As- sembly. At this point the Deflector sup- ported by the Guide Pins drops down to its operational position. The glass Bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, activating the sprinkler and allowing water to flow. Design Criteria The RFII (TY3551 & TY3504), 5 mm Bulb Type, Concealed Pendent Sprin- klers are UL and C -UL Listed as stand- ard response - standard spray sprin- klers for use in accordance with the current NFPA standard. They are FM Approved as standard response - standard spray sprinklers for use in accordance with the current FM Loss Prevention Data Sheets. The RFII (TY3531 & TY3505) 3 mm Bulb Type, Concealed Pendent Sprin- klers are UL and C -UL Listed as quick response - standard spray sprinklers for use in accordance with the current NFPA standard. They are FM Ap- proved as standard response - stand- ard spray sprinklers for use in accord- ance with the current FM Loss Prevention Data Sheets. The Series RFII Concealed Pendent Sprinklers are only listed and ap- proved with the Series RFII Concealed Cover Plates having a metallic or white painted finish. The Series RFII must not be used in applications where the air pressure above the ceiling is greater than that below. Down drafts through the Sup- port Cup could delay sprinkler opera- tion in a fire situation. Installation The Series RFII must be installed in accordance with the following instruc- tions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1116 inch (1,6 mm) for the 155°F1680C and 3132 inch (2,4 mm) for the 200°F/93°C tem- perature ratings. TFP181 1/2" NPT SEALING ASSEMBLY FRAME CAP SUPPORT CUP WITH BULB ROLL FORMED THREADS COMPRESSION SCREW GUIDE PINS (2) DEFLECTOR (DROPPED DEFLECTOR ;-�__- i ;�- �/ POSITION) � SPRINKLER/SUPPORT CUP ASSEMBLY THREAD INTO RETAINER SUPPORT CUP WITH THREAD UNTIL MOUNTING O O DIMPLES SURFACE IS FLUSH WITH EJECTION CEILING SPRING SOLDER COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY FIGURE 1 SERIES RFII CONCEALED SPRINKLER ASSEMBLY A leak tight 112 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprinkler Assembly by under- or over -tightening the Sprinkler/Support Cup Assembly. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be installed in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 4. Wrench tighten the sprinkler using only the RFII Sprinkler Wrench (Ref. Figure 3). The RFII Sprinkler Wrench is to be applied to the Sprin- kler as shown in Figure 3. Step 5. Replace the Protective Cap (Ref. Figure 4) by pushing it upwards until it bottoms out against the Support Cup. The Protective Cap helps prevent damage to the Deflector and Arms dur- ing ceiling installation and/or during application of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole by gently pushing the ceiling material up against the center point of the Protec- tive Cap. NOTE As long as the Protective Cap remains in place, the system is considered to be "Out of Service". Step 6. After the ceiling has been com- pleted with the 2-1/2 inch (63,5 mm) diameter clearance hole and in prepa- ration for installing the Cover Plate As- sembly, remove and discard the Pro- tective Cap, and verify that the Deflector moves up and down freely. If the Sprinkler has been damaged and " Registered Trademark of DuPont 0 N TFP181 FACE OF CLEARANCE HOLE SPRINKLER DIAMETER FITTING DIMENSION C SPRINKLER SUPPORT CUP ASSEMBLY 1/2"(12,7 mm) THREADED D ADJUSTMENT FACE OF CEILING, RETAINING RING MOUNTING SURFACE TT%a f COVER PLATE PROFILE DEPTH DIMENSION B COVER PLATE DIAMETER DIMENSION A A: 3-1/4" (82,6 mm) C: 2-3/8" to 2-5/8" (60,3 to 66,7 mm) B: 3/16" (4,8 mm) D: 1-3/4" to 2-1/4" (44,5 to 57,2 mm) FIGURE 2 SERIES RFII CONCEALED SPRINKLER INSTALLATION DIMENSIONS FRAME ARM SUPPORT CUP O 7/8'(23 mm) SQUARE ALIGN J ARROWS WITH FRAMEARMS cl � r ACCEPTS O 1/2" SOCKET DRIVE FIGURE 3 RFII SPRINKLER WRENCH Page 3of4 the Deflector does not move up and down freely, replace the entire Sprin- kler assembly. Do not attempt to mod- ify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5, otherwise proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the out- side edge of the seal is oriented ac- cording,to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. NOTE The Air and Dust Seal is only to be installed on the periphery of the Re- tainer. Step 8. Screw on the Cover Plate/Re- tainer Assembly until the Retainer - Figure 2 (or Air and Dust Seal - Figure 5) contacts with the ceiling. Do not continue to screw on the Cover Plate/Retainer, Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate/Retainer Assembly cannot be engaged with the Support Cup or the Cover Plate/Re- tainer Assembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance. The Series RFII must be maintained and serviced in accordance with the following instructions: NOTES Absence of the Cover Plate Assembly may delay sprinkler operation in a fire situation. When properly installed, there is a nominal 3132 inch (2,4 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 2. This �Lr== T___ ==z_- ---- r=� 3/16" to 11/16" MANUFACTURER DEFLECTOR COVER PLATE (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER REFERENCE 3/32"(2,4 mm) POSITION ASSEMBLY COVER PLATE PROFILE DEPTH DIMENSION B COVER PLATE DIAMETER DIMENSION A A: 3-1/4" (82,6 mm) C: 2-3/8" to 2-5/8" (60,3 to 66,7 mm) B: 3/16" (4,8 mm) D: 1-3/4" to 2-1/4" (44,5 to 57,2 mm) FIGURE 2 SERIES RFII CONCEALED SPRINKLER INSTALLATION DIMENSIONS FRAME ARM SUPPORT CUP O 7/8'(23 mm) SQUARE ALIGN J ARROWS WITH FRAMEARMS cl � r ACCEPTS O 1/2" SOCKET DRIVE FIGURE 3 RFII SPRINKLER WRENCH Page 3of4 the Deflector does not move up and down freely, replace the entire Sprin- kler assembly. Do not attempt to mod- ify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5, otherwise proceed to Step 8. To attach the Air and Dust Seal, verify the angle of the out- side edge of the seal is oriented ac- cording,to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. NOTE The Air and Dust Seal is only to be installed on the periphery of the Re- tainer. Step 8. Screw on the Cover Plate/Re- tainer Assembly until the Retainer - Figure 2 (or Air and Dust Seal - Figure 5) contacts with the ceiling. Do not continue to screw on the Cover Plate/Retainer, Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate/Retainer Assembly cannot be engaged with the Support Cup or the Cover Plate/Re- tainer Assembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance. The Series RFII must be maintained and serviced in accordance with the following instructions: NOTES Absence of the Cover Plate Assembly may delay sprinkler operation in a fire situation. When properly installed, there is a nominal 3132 inch (2,4 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 2. This Page 4 of 4 air gap is necessary for proper opera- tion of the sprinkler. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does NOT seal off any of the air gap. Factory painted Cover Plates MUST NOT be repainted. They should be re- placed, if necessary, by factory painted units. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Before closing a fire protection system main control valve for maintenance work on the fire protection system that itcontrols, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). If a sprinkler must be removed, do not reinstall it or a replacement without reinstalling the Cover Plate Assembly. If a Cover Plate Assembly becomes dislodged during service, replace it im- mediately. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relativeto any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Till 81 SUPPORT SPRINKLER FACE OF ORIENT CUP CEILING SEAL 56-792-1-135 BEVELAS Bright Brass SHOWN COVER Chrome PLATE 56-792-9-165 RETAINER 56-792-8-135 ASSEMBLY White 56-792-0-135 CLEAN Bright White ROOM LIP OF COVER SEAL RETAINER PLATE FIGURE 5 56-792-6-135 OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551 & TY3504) Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work - ma when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. roil "TP -1.111 •-J �- 0 1 I F20J. l Ordering Procedure When placing an order, indicate the full product name. Contact your local dis- tributor for availability. Sprinkler Assembly: Specify: (SIN), (specify temperature rating) Series RFII Concealed Pen- dent Sprinkler, P/N (specify). 155Ff68C 20OF193C TY3551 51-790-1-155 51-790-1-200 TY3504 51-796-1-155 51-796-1-200 TY3531 51-792-1-155 51-792-1-200 TY3505 51-797-1-155 51-797-1-200 Separately Ordered Cover Plate: Specify: (specify temperature rating) Series RFII Concealed Cover Plate with (specify finish), P/N (specify). For use with 155F/68C sprinklers. " For use with 200F/93C sprinklers. Sprinkler Wrench: Specify: RFII Sprinkler Wrench, P/N 56-000-1-075. Air and Dust Seal: Specify: Air and Dust Seal, P/N 56-908-1-001. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 US 135F/57C' 165Ff74C" Brass 56-792-1-135 56-792-1-165 Bright Brass 56-792-2-135 56-792-2-165 Chrome 56-792-9-135 56-792-9-165 Brushed Chrome 56-792-8-135 56-792-8-165 White 56-792-0-135 56-792-0-165 Bright White 56-792-4-135 56-792-4-165 Off White 56-792-5-135 56-792-5-165 Black 56-792-6-135 56-792-6-165 Custom 56-792-X-135 56-792-X-165 For use with 155F/68C sprinklers. " For use with 200F/93C sprinklers. Sprinkler Wrench: Specify: RFII Sprinkler Wrench, P/N 56-000-1-075. Air and Dust Seal: Specify: Air and Dust Seal, P/N 56-908-1-001. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 US 0 Model BV=QR � 5.6 K -factor EO NO Quick Response Standard Coverage Horizontal Sidewall Glass Bulb Automatic Sprinkler Tyco Fire Products --- www.centralsprinkler.com 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA Customer Service/Sales: Tel: (215) 362-0700 / Fax: (215) 362-5385 Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 General Description The Central Model BV -QR, 5.6 K -factor (1/2" orifice), Horizontal Sidewall & Recessed Horizontal Sidewall Sprinklers are quick response - standard coverage, glass bulb type spray sprinklers intended for use in fire sprinkler systems designed in accordance with the standard installa- tion rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on NFPA 13 require- ments). Horizontal Sidewall Sprinklers are generally used in lieu of pendent & upright sprinklers because of building construction or installation economy considerations. They are designed for installation along a wall or the side of a beam and just beneath a smooth ceiling. Installed with their centerline of waterway parallel to the ceiling, these sprinklers produce a quarter - spherical water discharge pattern that is predominately directed downward & outward from the deflector, however, a portion of the spray is also directed towards the backwall. The recessed version of the Central Model BV -QR, intended for use in areas with a finished walls, uses a two-piece Model BV Res✓QR Recessed Escutcheon. The Model BV Res/QR Recessed Escutcheon provides up to 3/8 inch (9,5 mm) of total adjustment from the flush horizontal sidewall position. These sprinklers are available with a polyester coating that may be utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmospheres. Although polyester coated sprinklers have passed the standard corrosion tests of the applicable approval agencies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of this corrosion resistant coating for any given corrosive environment The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. Operation: The glass bulb contains a fluid which expands when exposed to heat When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, which then allows the sprinkler to activate & flow water. WARNING The Model BV -QR Horizontal Sidewall Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards ofany other authorities having jurisdiction. Failure to do so may impair the integrity of these devices. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted relative to any questions. Technical Data Sprinkler Identification Number SIN C3301 Approvals UL & ULC Listed. FM & NYC Approved (The approvals apply only to the service conditions indicated in the Design Criteria Section) Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connection , 1/2 inch NPT Discharge Coefficient K = 5.6 GPM/psi" (80,6 LPM/bar'12) CENTRAL Standard Spray Horizontal Sidewall Sprinklers Temperature Ratings 135°F/57°C, 155°F/680C, 175°Fi79°C 200°F/93°C, 250°17/121 °C Finishes Sprinkler. White Polyester, Chrome Plated, or Natural Brass Rec. Escutcheon: White Coated, Chrome Plated, or Brass Plated Corrosion Resistant Coatings Sprinkler. White Polyester (UL only) Physical Characteristics The Model BV -QR Horizontal Sidewall Sprinklers utilize a dezincification resistant (DZR) bronze frame and a 3 mm bulb. The two-piece button assembly is brass and copper. The sprinkler frame orifice is sealed with a gasketed spring plate (Belleville Seal) consisting of a beryllium nickel disc spring that is sealed on both its inside and outside edges with a Teflonm gasket The compression screw is bronze, & the deflector is brass. No. 1-7.5 Figure 1 - Model BV -QR, Horizontal Sidewall Sprinkler TOP OF SPRINKLER DEFLECTOR 2-5/16" WRENCH (58,7 mm) FLAT \ t 7116" (11,1 mm) 1 1/2" NPT ELEVATION VIEW Figure 2 - Cross Section Model BV -QR, Horizontal Sidewall Sprinkler Design Installation Criteria 0 The 5.6 K -factor, Model BV -QR Horizontal Sidewall and Recessed Horizontal Sidewall Sprinklers (Ref. Table 1) are UL & ULC Listed and NYC Approved (MEA 466-92-E) as quick response - standard coverage, spray sprinklers for use in light and ordinary hazard occupancies in accordance with current NFPA standards. The 5.6 K -factor, Model BV -QR Horizontal Sidewall Sprinklers (Ref. Table 1) are FM Approved as quick response - standard coverage, spray sprinklers for use in light hazard occupancies in accordance with the FM Loss Prevention Data Sheets. The sprinklers are not FM approved for recessed applications. The Model BV -QR Sprinklers are listed and approved for installation 4" - 6" (101,6 - 152,4 mm) below the ceiling when measuring to the top of the sprinkler deflector. The Model BV -QR Sprinklers can be used with any metalic flush or extended escutcheon, provided the maximum sprinkler deflector to wall dimension specified in NFPA 13 is not exceeded. NOTE Inquiries concerning the appropriateness of polyester coated sprinklers for a given corrosive environment should be submitted to the attention of the Technical Services Department. Polyester coated sprinklers are not suitable for use in open sprinkler applications. The Model BV -QR Horizontal Sidewall Sprinklers must be installed in accor- dance with the following instructions. NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/570C to 3/32 inch (2,4 mm) for the 250°F/121 °C rating. A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maximum of 21 ft. lbs. (28,5 Nm) of torque is to be used to install 112 inch NPT sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under- or over -tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must be installed only in the sidewall position with the centerline of the sprinkler parallel to the ceiling and perpendicular to the wall. The top of the deflector is to be positioned toward the ceiling. Step 2. After installing the BV Res/QR support cup (or other escutcheon, as applicable) over the sprinkler pipe Table 1 - Laboratory Listings and Approvals, Model BV SPRINKLER GASKETED SPRING FRAME PLATE Chrome Plated (BELLEVILLE DEFLECTOR SEAL) / BUTTON 1,2,3,4 ASSEMBLY COMPRESSION 155117/680C SCREW GLASS BULB 1,2,3,4 OPERATING 1,2,4 ELEMENT Yellow Design Installation Criteria 0 The 5.6 K -factor, Model BV -QR Horizontal Sidewall and Recessed Horizontal Sidewall Sprinklers (Ref. Table 1) are UL & ULC Listed and NYC Approved (MEA 466-92-E) as quick response - standard coverage, spray sprinklers for use in light and ordinary hazard occupancies in accordance with current NFPA standards. The 5.6 K -factor, Model BV -QR Horizontal Sidewall Sprinklers (Ref. Table 1) are FM Approved as quick response - standard coverage, spray sprinklers for use in light hazard occupancies in accordance with the FM Loss Prevention Data Sheets. The sprinklers are not FM approved for recessed applications. The Model BV -QR Sprinklers are listed and approved for installation 4" - 6" (101,6 - 152,4 mm) below the ceiling when measuring to the top of the sprinkler deflector. The Model BV -QR Sprinklers can be used with any metalic flush or extended escutcheon, provided the maximum sprinkler deflector to wall dimension specified in NFPA 13 is not exceeded. NOTE Inquiries concerning the appropriateness of polyester coated sprinklers for a given corrosive environment should be submitted to the attention of the Technical Services Department. Polyester coated sprinklers are not suitable for use in open sprinkler applications. The Model BV -QR Horizontal Sidewall Sprinklers must be installed in accor- dance with the following instructions. NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/570C to 3/32 inch (2,4 mm) for the 250°F/121 °C rating. A leak tight 1/2 inch NPT sprinkler joint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maximum of 21 ft. lbs. (28,5 Nm) of torque is to be used to install 112 inch NPT sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutcheon Plate by under- or over -tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must be installed only in the sidewall position with the centerline of the sprinkler parallel to the ceiling and perpendicular to the wall. The top of the deflector is to be positioned toward the ceiling. Step 2. After installing the BV Res/QR support cup (or other escutcheon, as applicable) over the sprinkler pipe Table 1 - Laboratory Listings and Approvals, Model BV 1. Listed by Underwriters Laboratories, Inc. 2. Listed by Underwriters' Laboratories of Canada (ULC). 3. Approved by Factory Mutual Research Corporation. 4. Approved by the City of New York under MEA 466-92-E Vol. III 161 SPRINKLER FINISH & STYLE Temperature Rating Bulb Color Code Natural Brass Chrome Plated Polyester Coated Recessed 1351F/571C Orange 1,2,3,4 1,2,3,4 1,2,3,4 1,2,4 155117/680C Red 1,2,3,4 1,2,3,4 1,2,3,4 1,2,4 1751F/791C Yellow 1,2,3,4 1,2,3,4 1,2,3;4 1,2,4 2001F/931C Green 1,2,3,4 1,2,3,4 1,2,3,4 1,2,4 2501F/1210C Blue 1,2,3,4 1,2,3,4. 1,2,3,4 1,24 1. Listed by Underwriters Laboratories, Inc. 2. Listed by Underwriters' Laboratories of Canada (ULC). 3. Approved by Factory Mutual Research Corporation. 4. Approved by the City of New York under MEA 466-92-E Vol. III 161 Figure 3 - Model BV -QR, Recessed Horizontal Sidewall Sprinkler RECESSED SUPPORT CUP MODEL BV Res./QR y<, RECESSED OUTER ESCUTCHEON ESCUTCHEON RING threads & with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the BV Sprinkler Wrench (Ref. Figure 4). The BV Sprinkler Wrench is to be applied to the wrench flats only. Step 4. For applications using the BV - QR Rec. Horizontal Sidewall Sprinklers, a Protective Cap is available which helps to prevent damage to the sprinkler during ceiling/wall installation and/or during application of the finish coating of the ceiling/wall. Place the Protective Cap over the Recessed Support Cup and push it sideways until it bottoms out against the sprinkler deflector. NOTE As long as the Protective Cap remains in place, the system is considered "Out of Service. " Step 5. After the ceiling/wall has been completed, remove and discard the Protective Cap. If the sprinkler has been damaged, replace the entire sprinkler assembly. Do not attempt to modify or repair a damaged sprinkler. Step 6. Push the outer ring of the Recessed Escutcheon over the Recessed Support Cup. If the Outer Recessed Escutcheon Ring cannot be engaged with the Recessed Support Cup sufficiently to contact the wall, the sprinkler fitting must be repositioned. Care & Maintenance The Model BV -QR Horizontal Sidewall Sprinklers must be maintained and serviced in accordance with the following instructions. NOTES Absence of an escutcheon which is used to cover a clearance hole, may delay the time to operation in a fire situation. Before dosing a fire protection system main control valve for maintenance work on the fire protection system it controls, permission to shut down the affected fire protection systems must be obtained from the properauthorities. All personnel who may be affected by this action must be notified. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be shipped or stored where their tempera- tures will exceed 100°F/380C and they must never be painted, plated, coated or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage - before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installation Section). Frequent visual inspections are recom- mended to be initially performed for polyester dated sprinklers installed in corrosive environments, after the installation has been completed, to verify the integrity of the polyester coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of inspecting from the floor level, a random sampling of dose -up visual inspections should be made, so as to better determine the exact sprinkler condition and the long term integrity of the polyester coating, as it may be affected by the corrosive condi- tions present The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and devices in compli- ance with this document, as well as with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The installing contractor or sprinkler rimanufao- turer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Figure 4 - BV Sprinkler Wrench (Part #1099) 3/8" (9,5 mm) 4" (101,6 mm) FACE OF ;'; 3/4" (1�9 1 mm) 6" (152i,4 mm) FINISHED REDUCING Max Max CEILING LINE COUPLING WRENCH _ FLAT ' mm) Min. �__� 2-1/4" (57,2 mm) Max. j� `'I 2-7/8" (73,0 mm) RECESSED SUPPORT CUP MODEL BV Res./QR y<, RECESSED OUTER ESCUTCHEON ESCUTCHEON RING threads & with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the BV Sprinkler Wrench (Ref. Figure 4). The BV Sprinkler Wrench is to be applied to the wrench flats only. Step 4. For applications using the BV - QR Rec. Horizontal Sidewall Sprinklers, a Protective Cap is available which helps to prevent damage to the sprinkler during ceiling/wall installation and/or during application of the finish coating of the ceiling/wall. Place the Protective Cap over the Recessed Support Cup and push it sideways until it bottoms out against the sprinkler deflector. NOTE As long as the Protective Cap remains in place, the system is considered "Out of Service. " Step 5. After the ceiling/wall has been completed, remove and discard the Protective Cap. If the sprinkler has been damaged, replace the entire sprinkler assembly. Do not attempt to modify or repair a damaged sprinkler. Step 6. Push the outer ring of the Recessed Escutcheon over the Recessed Support Cup. If the Outer Recessed Escutcheon Ring cannot be engaged with the Recessed Support Cup sufficiently to contact the wall, the sprinkler fitting must be repositioned. Care & Maintenance The Model BV -QR Horizontal Sidewall Sprinklers must be maintained and serviced in accordance with the following instructions. NOTES Absence of an escutcheon which is used to cover a clearance hole, may delay the time to operation in a fire situation. Before dosing a fire protection system main control valve for maintenance work on the fire protection system it controls, permission to shut down the affected fire protection systems must be obtained from the properauthorities. All personnel who may be affected by this action must be notified. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be shipped or stored where their tempera- tures will exceed 100°F/380C and they must never be painted, plated, coated or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage - before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installation Section). Frequent visual inspections are recom- mended to be initially performed for polyester dated sprinklers installed in corrosive environments, after the installation has been completed, to verify the integrity of the polyester coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of inspecting from the floor level, a random sampling of dose -up visual inspections should be made, so as to better determine the exact sprinkler condition and the long term integrity of the polyester coating, as it may be affected by the corrosive condi- tions present The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and devices in compli- ance with this document, as well as with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The installing contractor or sprinkler rimanufao- turer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Figure 4 - BV Sprinkler Wrench (Part #1099) Limited Ordering Warranty n Information Products manufactured by Tyco Fire Products are warranted solely to the Ordering Information: When placing original Buyer for ten (10) years an order, indicate the full product against defects in material and name. Please specify the quantity, workmanship when paid for and model, style, orifice size, temperature properly installed and maintained rating, type of finish or coating, and under normal use and service. This sprinkler wrench. Refer to price list for warranty will expire ten (10) years complete listing of Part Numbers. . from date of shipment by Tyco Fire Products. No warranty is given for Teflon is a trademark of the DuPont Corp. products or components manufac- tured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, im- proper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's repre- sentatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSE- QUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRAN- TIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. t e Flow Control Tyco Fire l Products Printed in U.S.A. 2-01 E& EO -W1LKINS SPECIFICATION SUBMITTAL SHEET A COMPANY Model 350 Double Check Valve Assembly (Patent No. 5,913,331) FEATURES Sizes: ❑ 2 1/2" ❑ 3" g 4" ❑ 6" ❑ 8" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections Stainless steel, 300 Series (Grooved for steel) AWWA C606 (Flanged) ANSI 616.1 Elastomers Class 125 OPTIONS (Suffixes can be combined) ❑ - with NRS shut-off valves (standard) ❑ FS - with cast iron Wye type strainer ❑ FSC - with epoxy coated Wye type strainer ❑ G - with groove end gate valves ❑ FG - with flanged inlet gate connection and grooved outlet gate connection ❑ L - less shut-off valves (flanged body connections) ❑ OSY - with OS & Y gate valves ACCESSORIES ❑ Repair kit (rubber only) ❑ Thermal expansion tank (Model WXTP) ❑ Flange by Groove adapter (FLA) ❑ Gate valve tamper switch (OSY-40) APPLICATION Designed for installation on potable water lines to protect against both backsiphonage and backpressure of polluted wa- ter into the potable water supply.The Model 350 shall provide protection where a potential health hazard does not exist. STANDARDS COMPLIANCE (unless otherwise noted, applies to sizes 21/2" thru 6" Horizontal and Vertical flow -up) ❑ ASSEO Listed 1015 ❑ CSA® Certified (Horizontal and Vertical Flow -Up, 4" & 6") ❑ IAPMOO Listed (Horizontal and Vertical Flow -Up, 4"& 6") ❑ AWWA Compliant ❑ ULO Classified ❑ C-ULO Classified ❑ FMO Approved ❑ Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (Horizontal and Vertical Flow -Up, 4" & 6") MATERIALS Main valve body Ductile Iron ASTM A 536 Grade 4 Access covers Ductile Iron ASTM A 536 Grade 4 Coatings FDA Approved fusion epoxy finish Internals Stainless steel, 300 Series NORYLTM, NSF Listed Fasteners Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYLTM, NSF Listed Springs Stainless Steel, 300 Series 1 E 0 0 \0 0 0 0 0 0 e---� +F—D C A G DIMENSIONS & WEIGHTS (do not include pkg.) MODEL 3500SYG SHOWN DIMENSION (approximate) WEIGHT MODEL B E E WITHOUT WITH NRS WITH SIZE A LESS GATE C D OS&Y OS&Y F G GATE GATE NRS GATE GATE VALVES OPEN CLOSED VALVES VALVES VALVES in. I nun in. I mm in. I mm in. mm in. I mm in. mm in. mm in. I mm in. mm in. mm lbs. I kg lbs, I kg Ibs. I kg 21/2 65 1 31 791 15 7/8 403 3 3/4 95 7 1/41184 16 3/8 416 13 7/8 352 11 3/81.289 31/2 89 411/4 1048 53 24.1 155 70.4 163 74 3 80 32 816 15 7/8 403 3 3/4 95 7 1/4 184 18 7/8 479 15 5/8 397 12 3/8 314 3 1/2 89 42314 1086 53 24.1 177 80.4 183 83 4 100 37 5/8 956 19 1/2 495 4 1/2 114 8 203 22 3✓4 578 18 1/4 464 14 3/4 375 6 152 521/4 1327 91 41.3 271 123 281 127.6 6 150 445/8 1133 23 1/2 597 6 152 10 254 30 1/8 765 23'3/4 603 19 483 7 178 62 1/4115811165174.9 449 203.8 465 211 8 200 605/8 1540 37 1/2 953 10 254 11 279 37 3/4 959 29 1/4 743 22 1/2 572 216 84 7/8 2156 358 162.5 810 367.7 834 1378.61 PaPage1 of 2 g DOCUMENT "o. r;Ev BF -350 11/0. a15 FLOW CHARACTERISTICS Model 350 2 1/2" & 3" (STANDARD) 90 0 60 J W N 30 W a 0 0 200 400 600 800 FLOW RATES (U.S. GPM) Model 350 65 & 80mm (METRIC) a a15 fA y10 0 W 5 wW 0 W a 0 10 20 30 FLOW RATES (1/s) Model 350 4" & 6" (STANDARD) 40 50 90 0 60 J W 5 30 U) W CC 0 400 800 1200 1600 FLOW RATES (U.S. GPM) MODEL 350 100 & 150mm (METRIC) 0 20 40 FLOW RATE (US) 60. 80 100 O Rated Flow (Established by approval agencies) TYPICAL INSTALLATION Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance fortesting and maintenance. The installation shall be made so that no part of the unit can be submerged. 1--L.- DIREc-nON OF ROW CD OUTDOOR INSTALLATION VERTICAL INSTALLATION INDOOR INSTALLATION SPECIFICATIONS The Double Check Backflow Prevention Assembly shall be ASSEO Listed 1015, and supplied with full portgate valves. The main body and access covershall be epoxy coated ductile -iron (ASTM A 536 Grade 4), the seat ring and check valve shall be NORYLTIM , the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The checks shall be accessible for maintenance without removing the device from the line. The Double Check Backfiow Prevention Assembly shall be a WILKINS Model 350. Page 2 of 2 WILKINS OPERATION OF ZURN INDUSTRIES, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 11-2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1 -877 -BACKFLOW (1-877-222-5356) • Website: http://www.zurn.com LISTED�� 2-1/2" - 12" KENSEAL II R/W VALVE - OS & Y - FLANGED END ® 888H APPROVED GENERAL DIMENSION LAYOUT A.W.W.A Standard C509 KENNEDY VALVE 4068 H I l `) F i E X f � Std. Tap Size 1/2": 21/2"-4" t C � 3/4": 6"-12" G No. & 125 Ib. ANSI size of bolts std. drilling g D 816.1 A 4068A -Tapped & Plugged Upon Request @ Position "A" 1/2": 21/2"-4"; 3/a": 6"-12" VALVE SIZE A B C D E F G H Weight 2-1/2 7-1/2 3-3/4 7 11/16 13-7/8 16-3/8 4-5/8 7-1/4 55 3 8 4 7-1/2 3/4 15-5/8 18-7/8 4-5/8 10 70 4 9 4-1/2 9 15/16 118-1/4 22-3/4 8-5/8 10 100 6 10-1/2 5-1/4 11 1 23-3/4 30-1/8 8-3/4 12 150 8 11-1/2 5-3/4 13-1/2 1-1/8 29-1/4 37-3/4 8-3/4 14 250 10 13 6-1 /2 16 1-3/16 35-3/8 45-3/4 12-7/8 18 400 12 14 7 19 1-1/4 7 40-5/8 53-1/8 12-7/8 18 580 7 VSG PLOW FLOW RATE VANE TYPE WATERFLOW POTTER ® The Symbol of Protection SWITCH WITH ELECTRONIC RETARD U.S. Pat. No. 3921989, Canadian Pat. No. 1009680 Other Patents Pending, Potter Electric, Rd., 1990 GENERAL INFORMATION: TheModelVSGisaflexible vane type of waterflow switch for use in wet pipe water mist systems where a low flow for alarm is required. It is designed for installation in sections of 2 to 4 inch (50mm to 100mm) stainless steel or brass pipe with wall thickness in accordance with the above specifications (see "Nominal OD and Wall Thickness"). The unit may also be used as a sectional waterflow, detector on large systems. The unit contains an output relay and an adjustable electronic retard. The relay is actuated when a flow of 3 gallons per minute (11,4 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. ENCLOSURE: The unit is enclosed in a general purpose, die- cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which maybe used to indicate unauthorized removal of the cover. See bulletin no. 5400775 for installation instructions of this switch. UL and CSFM Listed Service Pressure: Up to 450 PSI (31 BAR) Flow Required for Alarm: 3.0 GPM (11,4 LPM) Maximum Surge: 18 FPS (5,5 m/s) Power Requirements: STANDBY: 1 Oma at 120V AC or 1.5ma at 24V AC/DC ALARM: 40ma at 120V AC or 35ma at 24V AC/DC Contact Ratings: DPDT (Form C) 2 Amps at 0-30VDC or 0-125VAC resistive Conduit Entrances: 2 knockouts provided for 1/2" conduit Environmental Specifications: • Suitable for indoor or outdoor use with factory installed gasket and die-cast housing. • NEMA 4 Rated Enclosure - use with appropriate conduit fitting. • Temperature Range: 40°F/120°F, 4,50C/490C • Non -corrosive sleeve factory installed in saddle. Caution: This device is not intended for applications in explosive environments. Nominal OD and Wall Thickness: 2" (60,3mm OD), 3,9mm to 4,5mm wall 2 1/2" (73,Omm OD), 4,8mm to 5,2mm wall 2 1/2" (76,1mm OD), 4,3mm to 4,7mm wall 3" (88,9mm OD), 5,Omm to 5,6mm wall 4" (114,3mm OD), 5,4mm to 6,4mm wall Service use: Water mist systems where low flow for alarm is required. Optional: Cover Tamper Switch Kit, Stock No. 0090018 INSTALLATION: See Fig. 1. These devices may be mounted on a horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The units should not be installed within 6" (15cm) of a fitting which changes the direction of the waterflow or within 24" (60cm) of a valve or drain. Drain the system and drill a hole in the pipe using a circular saw in a slow speed drill. The 2" (50mm) and 21/2" (65mm) devices require a hole with a diameter of 1 1/4" +1/8" -1/16" (32mm ± 2mm). The 3" (80mm) and 4" (100mm) devices require a hole with a diameter of 2" ± 1/8" (50mm ± 2mm). Clean the inside of the pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterflow. Install the saddle strap and tighten nuts alternately to an eventual 50 ft -lbs. (68 n -m) of torque. See Fig. 1. The vane must not rub the inside of the pipe or bind in any way. Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MKT. #8800008 - REV K PAGE t OF 2 MFG. #5400999 - 3/02 (2)POTTER ® The Symbol of Protection RETARD ADJUSTMENT The retard time is selected by turning the appropriate switches to the off position. Example: For 45 seconds turn switches 1, 2 and 3 to the off position. Approximate time is as follows: Switch Off Time in Sec. 1 thru 8 On 0 1 15 1 & 2 30 1,2,&3 45 1,2,3,&4 60 1,2,3,4,&5 75 1,2,3,4,5,&6 90 7 not used 8 not used FIG. 2 F6 0 6 660 IGRD N.C.G AUX.IC . G CONTACTS ..O.4s) HIGH VOLTAGE FIG. 1 TO IF _. DRILL NOLE AS NOICATED VSG LOW FLOW RATE VANE TYPE WATERFLOW O SWITCH WITH ELECTRONIC RETARD DO NOT LEAVE COVER OFT FOR EXTENDED PERIOD OF TIME RETARD TWE SELECTOR SWITCH 2" 10 2-1/2' -1-1/A' ♦ 1/6' - I/16' (50 1. 60mm) (3,-. t 2—) 3" Lo 1' 2" 3 1/B' (60 to 100—) (SO— 3 2—) 01RECION OF WATERFLOW TYPICAL ELECTRICAL CONNECTIONS U > 24V a BELL N 0 0 12OV 24V CON.. N.O. COY. N.C. M.C. G AUX., G CONTACTS N.O. G LOW VOLTAGE AC SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL s FIG. 3 Dir S DWG. /923-3 IM W. NUTS ALTERNATELY 10 AN EVENTUAL 50 FT. -LBS. (60 n -m) OF TOROUE ON SADDDLLE PPOONiSO IN DIRECTION OF WATENFLOW ROLL PADDLE IN OPPOSITE DIRECTgN OF WATERFLON DWG. /762-30 NOTE: BASE MUST BE CONNECTED TO A GOOD EARTH GROUND. LOW VOLTAGE DC DWG. 8985-1 CALMON: When supervised circuits are used the following must be observed: An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire be- comes dislodged from under the terminal. APPLICATION WARNING! Due to the possibility of unintended discharges caused by pressure surges, trapped air, or short retard times, waterflow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. TESTING: The operation of the waterflow switch and the associated alarms is to be tested upon completion of the installation and periodically thereafter in accordance with the applicable NFPA standards and/or the authority having jurisdiction (manufac- turer recommends quarterly or more frequently). A minimum flow of 3 GPM (11,4 LPM) is required to activate this device. PRINTED IN USA MKT. #8800008 - REV K PAGE 2 OF 2 MFG. #5400999 - 3/02 RELAY ACTION N.O. COY H.C. ALARM 4/6 WIRE CONTROL PANEL CIRCUIT DETECTOR CIRCUIT END OF UNE FROM PANEL + RESISTOR OR RETURN TO CONTROL PANEL 24V DC POwER� 24V DC RELAY 1-01 GRD 10 24V COM. H.D. m".HOc SHOWN ENERGIZED NOTE: BASE MUST BE CONNECTED TO A GOOD EARTH GROUND. LOW VOLTAGE DC DWG. 8985-1 CALMON: When supervised circuits are used the following must be observed: An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire be- comes dislodged from under the terminal. APPLICATION WARNING! Due to the possibility of unintended discharges caused by pressure surges, trapped air, or short retard times, waterflow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. TESTING: The operation of the waterflow switch and the associated alarms is to be tested upon completion of the installation and periodically thereafter in accordance with the applicable NFPA standards and/or the authority having jurisdiction (manufac- turer recommends quarterly or more frequently). A minimum flow of 3 GPM (11,4 LPM) is required to activate this device. PRINTED IN USA MKT. #8800008 - REV K PAGE 2 OF 2 MFG. #5400999 - 3/02 MODEL PS40A OPOTTER HIGH/LOW ® The Symbol of Protection PRESSURE SWITCHES E0 Fob MODEL PS40A PRESSURE SWITCH FOR MONITORING HIGH AND/OR LOW PRESSURE VARIATIONS PS40-1A Single Switch - Stock No. 1340401 PS40-2A Double Switch - Stock No. 1340402 The Potter PS40A Series are pressure actuated switches de- signed primarily to detect a 10 PSI (.7 BAR) increase and/or decrease from normal system pressure in automatic fire sprin- kler systems. Typical applications are air pressure supervision in dry pipe systems and pressure supervision of pressure tanks, air supply or water supply. INSTALLATION AND TEST PROCEDURES Mounting: Device should be mounted in upright position (thread- ed connection down). Requires NEMA type 4 conduit hub for outdoor installations. Dry System: Connect PS40A in air supply line on the system side UL and CSFM Listed, FM and LPC Approved, NYMEA Accepted, CE Marked ' Dimensions: 4 3/4" (12,lcm)W x 2 1/4" (5,7cm)D x 4 3/8" (11,1cm)H Enclosure: Cover -Die-cast with textured red powdercoat finish. Base - Plated Steel Pressure Connection: 1/2" NPT Male Factory Adjustment: PS40-1A: Operates on decrease at 30 PSI (2,1 BAR) PS40-2A: Operates on increase at 50 PSI (3,5 BAR), and on decrease at 30 PSI (2,1 BAR) Pressure Range: 10 - 175 PSI (0,7 - 12,1 BAR) Maximum Differential: Approx. 2lbs. at20 PSI (0,14@1,4 BAR) 5 lbs. at 175 PSI (0,35@12,1 BAR) Maximum System Pressure: 250 PSI (17,2 BAR) Switch Contacts: SPDT (Form C) 15.0 Amps at 125/250VAC, 2.5 Amps at 30VDC One set in PS40-1 A, Two sets in PS40-2A Environmental Specifications: Indoor or outdoor use NEMA 4/IP55 Rated Enclosure - when used with proper conduit fittings Temperature range: -40°F to 140°F (-40°C to 60°C) (Not for use in hazardous locations) Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Tamper: Cover incorporates tamper resistant fasteners that require a special key for removal. One key is supplied with each device. For optional cover tamper switch kit, order Stock No. 0090134. of any shutoff or check valve. Provision for testing the unit can be accomplished with the installation of Potter BleederValve (Model BVL) in the line to the PS40A. Testing: The operation of the pressure supervisory switch should be tested upon completion of installation and periodically thereafter in accordance with the applicable NFPA codes and standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). CAUTION: Testing the PS40A may activate other system con- nected devices. Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MKT. #8810002 - REV S PAGE 1 OF 2 MFG. #5400924 - 12101 MODEL PS40A HIGH/LOW O (E)POTTER The Symbol of Protection PRESSURE SWITCHES DIMENSIONS NOTE: TO PREVENT LEAKAGE, APPLYTEFLON TAPE SEALANT TO MALE THREADS ONLY. WARNING: USE OF PIPE JOINT CEMENT MAY RESULT IN OBSTRUC- TION OFAPERTUREAND LOSS OF SIGNAL. FIELD ADJUSTMENTS: The operating point of the switch (or switches on the PS40-2A) can be adjusted to any point between 10 and 175 PSI (0,7 and 12,1 BAR) by turning the adjustment knob(s) clockwise to raise the actuation point, and counter -clockwise to lower the actuation point. In the case of the PS40-2A, the two switches operate completely independently of one another, and each switch may be adjusted to actuate at any point the system requires. Final adjustment should be made with a pressure gauge. Typical Sprinkler Application - Dry System VALVEOff AVE h9LEE0EN P$tOA �1 GEGt 1M VE Ordering Information rogoS K VALVE 8VL $W11CN Description Stk. No. CAUTION: PS40-1A CNEO, 9V5 1340401 DR VALVE PS40-2A PIPE VALVE .-3. conductor should not be looped •AIER 0116. 1924-1 05 R -v By -PASS around the terminal and serve as two separate connections. The wire must vµv[ ZV VALVE I I I G O ADJI157NENT i (T.am) I "Noss u Ltd„) 2.M 4.Tso DWG. 1924-30 (3.hm) I12.Idn) Pressure Switch Terminations PRESSURE N.C. N.C. INCREASE COM. COM. N.O. N.O. PRESSURE DECREASE COM. N.O. N.C. COM. N.O. N.C. DWG. #926-3 Typical Electrical Connections LOCAL CIRCUIT 'T" B (CLASS B) SUPEfN/SE—D GRCUIT HIGH LOW NC / {►\�A�,Jy x.c. END mN. SIGNALNG COy. GpY, N0. DEVICE LONE RES TO n.o. POWER N.C. N,O. N.C. N.O.ISTOR DWG. /926-4A NIGH LOW NOTE: Switches are shown in standby condition with "normal" pressure applied. Switch #1 (high) changes with pressure increase. Switch #2 (low) changes with pressure decrease. Engineer/Architect Specifications Air pressure supervisory switch shall be a Model PS40A as manufactured by Potter Electric Signal Co. of St. Louis, Mo. and shall be installed on the sprinkler systems as shown on the drawings and/or as specified herein. Switches shall be provided with a 1/2" NPT male pressure connection to be connected into the air supply line on the system side of any shut-off valve. A Model BVL bleeder valve as supplied by Potter Electric Signal Co. of St. Louis, Mo. or equivalent shall be connected in line with the PS40A to provide a means of testing the operation of the supervisory switch. (See DWG. #924-1) The switch unit shall contain SPDT (Form C) switch(es). One switch shall operate at a pressure decrease of 10 PSI (0,7 BAR) from normal. If two switches are provided, the second switch shall operate at a pressure increase of 10 PSI (0,7 BAR) from normal. Switch contacts shall be rated at 15.0 Amps at 125/250VAC and 2.5 Amps at 30VDC. The units shall have a maximum pressure rating of 250 PSI (17,2 BAR) and shall be adjustable from 10 to 175 PSI (0,7 to 12,1 BAR). The switch housing shall be weatherproof and oil resistant. The cover shall incorporate tamper resistant screws. The unit shall be UL and CSFM Listed, FM and LPC Approved, and NYMEA Accepted. PRINTED IN USA MKT. #8810002 - REV S PAGE 2 OF 2 MFG. #5400924 - 12/01 Switch Terminal Connections Clamping Plate Terminal Ordering Information Model Description Stk. No. CAUTION: PS40-1A Pressure switch with one set SPDT contacts 1340401 An uninsulated section of a single PS40-2A Pressure switch with two sets SPDT contacts 1340402 conductor should not be looped BVL Bleeder Valve Hex Key 1000018 5250062 around the terminal and serve as two separate connections. The wire must Cover Tamper Switch 0090134 s be severed, thereby providing super - BVS 1/2" Ball Valve with tamper switch 1010150 vision of the connection in the event DWG. #923-3 that the wire becomes dislodged from under the terminal. Engineer/Architect Specifications Air pressure supervisory switch shall be a Model PS40A as manufactured by Potter Electric Signal Co. of St. Louis, Mo. and shall be installed on the sprinkler systems as shown on the drawings and/or as specified herein. Switches shall be provided with a 1/2" NPT male pressure connection to be connected into the air supply line on the system side of any shut-off valve. A Model BVL bleeder valve as supplied by Potter Electric Signal Co. of St. Louis, Mo. or equivalent shall be connected in line with the PS40A to provide a means of testing the operation of the supervisory switch. (See DWG. #924-1) The switch unit shall contain SPDT (Form C) switch(es). One switch shall operate at a pressure decrease of 10 PSI (0,7 BAR) from normal. If two switches are provided, the second switch shall operate at a pressure increase of 10 PSI (0,7 BAR) from normal. Switch contacts shall be rated at 15.0 Amps at 125/250VAC and 2.5 Amps at 30VDC. The units shall have a maximum pressure rating of 250 PSI (17,2 BAR) and shall be adjustable from 10 to 175 PSI (0,7 to 12,1 BAR). The switch housing shall be weatherproof and oil resistant. The cover shall incorporate tamper resistant screws. The unit shall be UL and CSFM Listed, FM and LPC Approved, and NYMEA Accepted. PRINTED IN USA MKT. #8810002 - REV S PAGE 2 OF 2 MFG. #5400924 - 12/01 MODEL PS10A QPOTTER PRESSURE SWITCH ® The Symbol of Protection PS10-1A Single Switch - Stock No. 1340101 PS10-2A Double Switch - Stock No. 1340102 INSTALLATIONANDTESTPROCEDURES UL and CSFM Listed, FM and LPCApproved, NYMEAAccepted, CE Marked Dimensions: 4 3/4" (12,1 cm)W x 21 /4" (5,7cm)D x 4 3/8" (11,1 cm)H Enclosure: Cover -Die-cast with textured red powdercoat finish Base - Plated Steel Pressure Connection: 1/2"NPT Male Factory Adjustment: Operates on Pressure increase at 6 ±1 PSI (0,41±0,07 BAR) Operates on Pressure decrease at5±1 PSI (0,35±0,07BAR) Maximum Differential: 1 PSI (0,06 BAR) Maximum System Pressure: 250 PSI (17,2 BAR) Switch Contacts: SPDT(Form C) 15.0 Amps at 125/250VAC, 2.5 Amps at 30VDC One set in PS 10-1 A, Two sets in PS10-2A Environmental Specifications: Indoor or outdoor use NEMA4/IP55 Rated Enclosure -when used with properconduit fittings Temperature range: -40"F to 140'F (-40°C to 60°C), (Notfor use in hazardous locations) Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential Occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Tamper: Cover incorporates tamper resistant fasteners that require a special keyfor removal. One key is supplied with each device. Foroptional cover tamper switch kit, order Stock No. 0090134. installed on the alarm outlet side of the retard chamber of the sprinkler The Potter PS 1 OA Series Pressure Actuated Switches are designed for system. the detection of a waterflow cond ition in automatic fire sprinkler systems of particular designs such as wet systems with alarm check valves or dry pipe systems. They may also be used to provide a low pressure supervisory signal. They may be adjusted to operate on pressure between 4 and 20 PSI (0,27 and 0,4 BAR). MOUNTING: Device should be mounted in upright position (threaded connection down). Requires NEMA type 4 conduit hub for outdoor installations. TESTING: The operation of the pressure alarm switch should betested upon completion of installation and periodically thereafter in accordance with the applicable NFPA codes and standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more fre- quently). WETSYSTEM: METHOD 1: When using PS1OAandcontrol unitwithretard -connect PS 1 OA into alarm port piping on the input side of retard chamber and electrically connect PS10A to control unit that provides a retard to compensate for surges. Insure that no unsupervised shut-off valves are present between the alarm check valve and PS1 OA. METHOD2: When using the PS 1 OA for local bell application or with a control that does not provide a retard feature - the PS OA must be TESTING: Accomplished by opening the inspector's end -of -line test valve. Allow time to compensate for system or control retard. CAUTION: Method 2 is not applicable for remote station service use, if there is an unsupervised shut-off valve between the alarm check valve and the PS 10A. WETSYSTEM WrTH EXCESS PRESSURE: Connect PS OA into alarm port piping extending from alarm check valve. Retard provisions are not required. Insure that no unsupervised shut- off valves are present between the alarm check valve and the PS OA. TESTING: Accomplished by opening the water by-pass test valve or the inspector's end -of -line test valve. When using end -of -line test, allow time for excess pressure to bleed off. DRYSYSTEM: Connect PS1 OA into alarm port piping that extends from the intermediate chamber of the alarm check valve. Install on the outlet side of the in-line check valve of the alarm port piping. Insure that no unsupervised shut- off valves are present between the alarm check valve and the PS10A. TESTING: Accomplished by opening the water by-pass test valve. CAUTION: The above tests may also activate any other circuit closer or water motor gongs that are present on the system. 0 Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MKT. #8810001 - REV U PAGE 1 OF 2 MFG. #5400923 - 12/01 (E)POTTER ® The Symbol of Protection DIMENSIONS NOTE: FFW I I TO PREVENT LEAKAGE, APPLY I I AaNusMEMr I @ I z.nD TEFLON TAPE I SEALANT TO MALE THREADS ONLY, WARNING: USE OF PIPE JOINT CEMENT MAY RESULT IN OBSTRUCTION OF LW I THE APERTURE AND LOSS OF SIGNAL. (�Lln �3.HA (ala^) DWG. #923-1 2.2W 4.7W I'. 7=) (12.Ia") TYPICAL SPRINKLER APPLICATIONS WET SYSTEM WITHOUT EXCESS 'PRESSURE PSIM WATER MOTOR GONG fM RETARD NATER Y (i -PASS VALVE WET SYSTEM DRY SYSTEM WITH EXCESS PRESSURE WET SYSTEM PSIM ALARM CHECK WATER MOTOR GOA& WET BVS RETARD SYSTEM SWITCH WATER MOTOR CHECK 1340102 VALVE MY CHECK VALVE WATER OS k Y BY PASS VALVE VALVE WET SYSTEM WITHOUT EXCESS 'PRESSURE PSIM WATER MOTOR GONG fM RETARD NATER Y (i -PASS VALVE MODEL PS10A O PRESSURE SWITCH SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL s �c Dui DWG. 1923-3 CAUTION: An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. DRY SYSTEM Description WET SYSTEM ISIM ALARM CHECK VALVE Pressure switch with one set SPDT contacts 1340101 SWITCH WATER MOTOR OS a 1340102 VALVE MY MODEL PS10A O PRESSURE SWITCH SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL s �c Dui DWG. 1923-3 CAUTION: An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. CAUTION: Closing of any shutoff valves between the alarm check valve and the PS10A will render the PS10A inoperative. To comply with NFPA-72 any such valve shall be electrically supervised with a supervisory switch such as Potter Model BVS. TYPICAL ELECTRICAL CONNECTIONS LUCAL CIRCUIT TRANSFORMER OR BATTERY POWER STYLE 0 (CLASS A) SUPERVISED LOOP STYLE 8 (CLASS B) SUPERVISED CIRCUIT N.C. SIGNALMG COM. COY. TO H.C. N DEVICE N.O. .0. COMiNL COM NA. EIA--LINE�RE9STOP R" GIRT OWC. /933-15 ORDERING INFORMATION DRY SYSTEM Description Stock ISIM AUIM PRESSURE Pressure switch with one set SPDT contacts 1340101 SWITCH WATER MOTOR Pressure switch with two sets SPDT contacts 1340102 GONG MY CHECK VALVE BYS SYSTEM 0090134 BVS ALARM CHECK 1010150 VALVE WATER OS k Y BY-PASS VALVE v'�� DWG. 0923-2 CAUTION: Closing of any shutoff valves between the alarm check valve and the PS10A will render the PS10A inoperative. To comply with NFPA-72 any such valve shall be electrically supervised with a supervisory switch such as Potter Model BVS. TYPICAL ELECTRICAL CONNECTIONS LUCAL CIRCUIT TRANSFORMER OR BATTERY POWER STYLE 0 (CLASS A) SUPERVISED LOOP STYLE 8 (CLASS B) SUPERVISED CIRCUIT N.C. SIGNALMG COM. COY. TO H.C. N DEVICE N.O. .0. COMiNL COM NA. EIA--LINE�RE9STOP R" GIRT OWC. /933-15 ORDERING INFORMATION Model Description Stock No. PS10-1A Pressure switch with one set SPDT contacts 1340101 PS10-2A Pressure switch with two sets SPDT contacts 1340102 Hex Key 5250062 Cover Tamper Switch Kit 0090134 BVS 1/2" Ball Valve with tamper switch 1010150 APPLICATION WARNING! Due to the possibility of unintended discharges caused by pressure surges, trapped air, or short retard times, waterflow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. PRESSURE SWITCH TERMINATION INCREASING SYSTEM PRESSURE '0 - TYPICAL WATERFLOW NST ON COM. N.O. N.C. SWITCH MARKINGS TYPICAL LOW PRESSURE SUPERVISION DECREASING SYSTEM PRESSURE COM. N.O. N.C. SWITCH MARKINGS CONTACT PoSRTON SHOWN WITH DEVICE IN PRESSURIZED CONDITION DWG. #962-4 0 ENGI NEER/ARCHITECTSPECIFICATIONS Pressure type waterflow switches shall be a Model PS10A as manufactured by Potter Electric Signal Co. of St. Louis, Mo. and shall be installed on the sprinkler systems as shown on the drawings and/or specified herein. Switches shall be provided with a 1/2" NPT male pressure connection to be connected into the alarm check valve of a "wet" sprinkler system or into the intermediate chamber of a "dry" pipe system and shall be actuated by any flow of water to or in excess of the discharge from one sprinkler head. Switches shall have a maximum service pressure rating of 250 PSI (17,2 BAR) and shall be factory adjusted to operate on pressure increase at 6 ±1 PSI (0,4 ±0,06 BAR). There shall be one (1) or two (2) SPDT contacts rated at 15.0 Amps at 1251250VAC and 2.5 Amps at 30VDC. The switch housing shall be weather proof and oil resistant. The cover shall incorporate tamper resistant screws. ! 1 The unit shall be UL and CSFM Listed, FM and LPC Approved, and NYMEA Accepted. l�✓! PRINTED IN USA MKT. #8810001 - REV U PAGE 2 OF 2 MFG. #5400923 - 12/01 OSYS U -1, -2 OPOTTER OUTSIDE SCREW AND YOKE VALVE ® The Symbol of Protection SUPERVISORY SWITCH N EO X417 OSYSU-1 Stock No. 1010106 OSYSU-2 Stock No. 1010206 GENERAL INFORMATION The OSYSU is used to monitor the open position of an OS & Y (outside screw and yoke) type gate valve. This device is available in two models; the OSYSU-1, containing one set of SPDT (Form C) contacts and the OSYSU-2, con- taining two sets of SPDT (Form C) contacts. These switches mount conveniently to most OS & Y valves ranging in size from 2" to 12" (50mm to 300mm). They will mount on some valves as small as 1/2" (12,5mm). The cover is held in place by two tamper resistant screws that require a special tool to remove. The tool is furnished with each device and should be left with the building owner or responsible party. Replacement or additional cover U L and CSFM Listed, FM Approved, NYMEA Accepted, CE Marked Dimensions: 6.19"L X 2.25"W X 5.88"H 15,7cm L X 5,7cm W X 14,6cm H Weight: 2 lbs. (0,9 kg.) Enclosure: Cover - Die -Cast Finish - Red Spatter Enamel Base - Die Cast Zinc All parts have corrosion resistant finishes. Cover Tamper: Tamper resistant screws, Optional cover tamper kit available. Contact Ratings: OSYSU-1: One set of SPDT (Form C) OSYSU-2: Two sets of SPDT (Form C) 15.00 Amps at 125/250VAC 2.50 Amps at 30VDC resistive Environmental Limitations: • NEMA 4 and NEMA 6P Enclosure (IP67) when used with appropriate watertight conduit fittings. • Indoor or Outdoor use (Not for use in hazardous locations. See bulletin no. 5400705 OSYS-U-EX for hazardous locations.) • Temperature Range: -40°F to 140°F (-40°C to 60'C) Conduit Entrances: 2 knockouts for 1/2" conduit provided Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 screws and hex keys are available. See ordering informa- tion on page 4. OPTIONAL COVER TAMPER SWITCH A field installable cover tamper switch is available as an option which may be used to indicate removal of the cover. See ordering information on page 4. TESTIN G The OSYSU and its associated protective monitoring sys- tem should be inspected and tested in accordance with applicable NFPA codes and standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MKT. #8820004 - REV P 12/01 PAGE 1 OF 4 OSYSU-1, -2 OUTSIDE SCREW AND YOKE VALVE (E)POTTER The Symbol of Protection SUPERVISORY SWITCH FIG. 1 SMALL VALVE INSTALLATION -1/2" THRU 21/2" (12,5mm THRU 63,5mm) SIZES THESE SWITCHES MOUNT CONVENIENTLY TO MOST 2" TO 12" OS & Y VALVES. THEY WILL MOUNT ON SOME VALVES AS SMALL AS 1/2" (12,5MM). J -HOOKS MAY BE REQUIRED ON VALVES WITH LIMITED CLEARANCE. CLAMP BAR CARRIAGE BC SMALL VALVE INSTALLATION 1. Remove and discard "C" washer and roller from the trip rod. 2. With the valve in the FULL OPEN position, locate the OSYSU across the valve yoke as far as possible from the valve gland, so that the trip rod lays against the non - threaded portion of the valve stem. 3. Loosen the locking screw that holds the trip rod in place and adjust the rod length (see Fig. 4). When adjusted properly, the rod should extend past the valve screw, but not so far that it contacts the clamp bar. Tighten the locking screw to hold the trip rod in place. NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the 1" (25mm) long notched section (see Fig. 5). Reinstall trip rod and repeat Step 3 procedure. 4. Mount the OSYSU loosely with the carriage bolts and clamp bar supplied. On valves with limited clearance use J -hooks supplied instead of the carriage bolts and clamp bar to mount the OSYSU. 5. Mark the valve stem at the center of the trip rod. SLOTTED MOUNTING HOLES MAY BE USED FOR FINE ADJUSTMENT OF SWITCH ON BRACKET BRACKET DWG. #979-3 6. Remove the OSYSU. File a 1/8" (3,2mm) deep groove centered on the mark on the valve stem utilizing a 3/16" (4,8mm) round, non-tapered file. Round and smooth the edges of the groove to prevent damage to the valve packing and to allow the trip rod to move easily in and out of the groove as the valve is operated. 7. Mount the OSYSU with the trip rod centered in groove. 8. Final adjustment is made by loosening 2 screws (see Fig. 1) and sliding the OSYSU on the bracket- Adjustment is correct when switches are not activated with the trip rod seated in the valve stem groove and that the switches activate when the trip rod moves out of the groove. 9. Tighten the adjustment screws and all mounting hardware. Check to insure that the rod moves out of the groove easily and that the switches activate within one tum when the valve is operated from the FULL OPEN towards the CLOSED position. NOTE: CLOSE THE VALVE FULLY TO DETERMINE THAT THE STEM THREADS DO NOT ACTIVATE THE SWITCH. THE SWITCH BEING ACTIVATED BY THE STEM THREADS COULD RESULT IN A FALSE VALVE OPEN INDICATION. PRINTED IN USA MKT. #8820004 - REV P PAGE 2 OF 4 12/01 OSYSU-15 -2 (E)POTTER OUTSIDE SCREW AND YOKE VALVE ® The Symbol of Protection SUPERVISORY SWITCH FIG. 2 LARGE VALVE INSTALLATION - 3" THRU 12" (76mm THRU 300mm) SIZES 3" THRU 12" (76mm THRU 300mm) VALVES BRACKET USE CARRIAGE BOLTS. BOLTS MOUNT ON INSIDE OF YOKE, IF THERE CLAMP BAR IS SUFFICIENT CLEARANCE. CARRIAGE BOLTS SLOTTED MOUNTING (2 REQUIRED) HOLES. MAY BE USED ROLLER FOR FINE ADJUSTMENT GROOVE OF SWITCH ON BRACKET. YOKE m VALVE STEM TRIP ROD DWG. #979-4 11=_1 N GLAND LARGE VALVE INSTALLATION 1. With the valve in the FULL OPEN position, locate the OSYSU across the valve yoke as far as possible from the valve gland, so that the trip rod lays against the non - threaded portion of the valve stem. 2. Mount the OSYSU loosely with the carriage bolts and clamp bar supplied. 3. Loosen the locking screw that holds the trip rod in place and adjust the rod length (see Fig. 4). When adjusted properly, the rod should extend past the valve screw, but not so far that it contacts the clamp bar. Tighten the locking screw to hold the trip rod in place. NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the one 1" (25mm) long notched section (see Fig. 5). Reinstall trip rod and repeat Step 3 proce- dure. 4. Mark the valve stem at the center of the trip rod. 5. Remove the OSYSU. File a 1/8" (3,2mm) deep groove centered on the mark of the valve stem utilizing a 3/8" PRINTED 1N USA (9,5mm) round, non-tapered file. Round and smooth the edges of the groove to prevent damage to the valve packing and to allow the trip rod to move easily in and out of the groove as the valve is operated. 6. Mount the OSYSU loosely with the trip rod centered in groove. 7. Final adjustment is made by loosening 2 screws (see Fig. 2) and sliding the OSYSU on the bracket. Adjustment is correct when switches are not activated with the trip rod seated in the valve stem groove and that the switches activate within one turn when the valve is operated from the FULL OPEN towards the CLOSED position. 8. Tighten the adjustment screws and mounting hardware. Check to insure that the rod moves out of the groove easily and that the switches activate within one turn when the valve is operated from the FULL OPEN towards the CLOSED position. NOTE: CLOSE THE VALVE FULLY TO DETERMINE THAT THE STEM THREADS DO NOT ACTIVATE THE SWITCH. THE SWITCH BEING ACTIVATED BY THE STEM THREADS COULD RESULT IN A FALSE VALVE OPEN INDICATION. MKT. #8820004 - REV P 12/01 PAGE 3 OF 4 OSYSU-15 -2 OUTSIDE SCREW AND YOKE VALVE (E)POTTER The Symbol of Protection SUPERVISORY SWITCH FIG. 3 DIMENSIONS I I Rop pR�p I OCG. 181#-5 BREAKING EXCESSIVE ROD LENGTH FIG. 5 o DWG. #979-7 FIG. 4 PARTS SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL _ �I 0N� oNG. /923-3 CAUTION: An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervi- sion of the connection in the event that the wire becomes dislodged from under the terminal. ORDERING INFORMATION r r ssure reducer a N.O. MODEL DESCRIPTION STOCK NO. OSYSU-1 Outside Screw & Yoke -Supervisory Switch (Single switch) 1010106 OSYSU-2 Outside Screw & Yoke -Supervisory Switch (Double switch) 1010206 — Cover Screw 5490344 — Hex Key for Cover Screws and Installation Adjustments 5250062 — Optional Cover Tamper Switch Kit 0090131 F valve installation kits (if r uired) contact valve manufacturer MN CRN ROD m TYPICAL ELECTRICAL CONNECTIONS LOCAL CIRCUIT N.O. INDICATING TO POWER FOR COM. N.C. DEVICE INDICATING DEVICE TO SUPERVISORY CIRCUIT END OF N.O. OF CONTROL PANELLINE COM. N.C. RESISTOR DWG. #979-1 Contacts shown in normal (valve open) condition. TYPICAL SWITCH ACTION OPEN VALVE POSITION COM. i N 0 SW #1 N.C. COM. i N 0 SW #2 N.C. CLOSED VALVE POSITION COM.CN.N.C. SW #i COM. N.O. SW #2 N.C. I o P e IYP e9 DWG. #979-2 PRINTED IN USA MKT. #8820004 - REV P PAGE 4 OF 4 12101 BELLS PPOTTER PBA -AC & PBD -DC The Symbol of Protection UL Listed, FM Approved Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling BurglarAlarm Environment: Indoor or outdoor use (See Note 1) -40° to 150°F (40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination: 4 No. 18 AWG stranded wires 6" BELL SHOWN Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox OThese vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power con- sumption and high decibel ratings. The unit mounts on a standard 4" (101 mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. ALL DC BELLS ARE POLARIZED AND HAVE BUILT-IN TRANSIENT PROTECTION: SIZE INCHES I—) VOLTAGE MODEL NO. STOCK NO. CURRENTAT (MAX.) TYPICAL dB 10 Fr. (3-)(2) MINIMUM dB AT 10 Fr. (3-)(1) 6 (150) 12VDC PBD126 1706012 .12A 85 76 8 (200) 12VDC PBD128 1708012 .12A 90 76 10(250) 12VDC PBD1210 1710012 .12A 92 76 6(150) 24VDC PBD246 1706024 .06A 87 76 8(200) 24VDC PBD248 1708024 .G6A 91 79 10 (250) 24VDC PBD2410 1710024 .06A 94 79 6(150) 24VAC PBA246 1806024 .17A 91 76 8(200) 24VAC PBA248 1808024 .17A 94 76 10 (250) 24VAC PSA2410 1810024 .17A 94 76 6(150) 120VAC PBA1206 1806120 .05A 92 82 8(200) 120VAC PBA1208 1808120 .05A 99 82 10(250) 120VAC PBA12010 1810120 .05A 99 85 Notes: 1. Minimum d6 ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 150°F (-34° to 66°C). 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. OPotter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MKT. #8850001 - REV Q PAGE 1 OF 2 MFG. #5400776 - 12/01 BELLS PBA -AC & PBD-DC(E)POTTER The Symbol of Protection FIG. 1 10" (250) -�I 2 1 1 / 16" -r (68) BELLS .1 1 (200) 6" (150) DWG. 1776-1 DIMENSIONS INCHES (mm) FIG.2 WEATHERPROOFBACKBOX BOX HAS ONE THREADED 1 /2" CONDUIT ENTRANCE J\"'T 5 3/4" (146) • (41) DWG. #775-2 3 3/8- (8 a 1 (108) FIG. 3 WIRING (REAR VIEW) O.C. BELLS (OBSERVE POLARITY) A.C. BELLS REO (IN) REO (OUT) WHITE IN WHITE (OUT) 0 0 FROM CONTROL PANEL :(OUT) ELL FROM CONTROL PANEL OR -UNE OR PRECEDING BELLR PRECEDING BELL(IN) BLABLACK (IN) °CBLIACK A I N WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: 1. OBSERVE POLARITY TO RING D.C. BELLS. 2. RED WIRES POSITIVE (+) 3. BLACK WIRES NEGATIVE (—) DWG. #776-3 CAUTION: WHEN ELECTRICAL SUPERVISION 5 REQUIRED USE IN AND OUT LEADS AS SHOWN. 5" (127) NOTES: 1. WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL. 2. END—OF—LINE RESISTOR IS NOT REQUIRED ON A.C. BELLS. 11 INSTALLATION 1. The bell should be mounted a minimum of 8 ft. (2,4m) from the floor or as close to the ceiling as possible. 2. Removethegong. 3. Connect wiring (see Fig. 3). 4. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 5. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 6. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). PRINTED IN USA MKT. #8850001 - REV Q PAGE 2 OF 2 MFG. #5400776 - 12/01 t 1 1 E9 ANGLE FEMALE x MALE I DOUBLE FEMALE FUNCTION: Used with a fire hose rack assembly or as a fire dept outlet connection. REGULARLY FURNISHED: Cast brass valve with red handwheel. Female NPT inlet x male hose thread outlet. 300 PSI120.6 bars. Model 4060 .....................1:4'13.8 cm Size "'►4065 .....................23,416.4 cm Size SPECIFY: Thread OPTIONAL FINISHES: —B Polished Brass —C Rough Chrome Plated —D Polished Chrome Plated VARIATIONS: Extended stem up to 24"161 cm, SPECIFY: Length :61.3 cm petcock SPECIFY: Location. Closed Open> s " ULA A Aop 8 C C D E &� LGsied tiaie 'YES C C U E YES 2'/4 3'h 672 Th 2'h 2 8 8cm ; 5.7 8.9 16.5 19 6.4 5 vl"Pt"YES YES 3'h 5 941 1 P 3'h 2'h 6 4cm, 8.9 12.7 24.1 29.2 8.9 1 6.9 FUNCTION: Used with a fire hose rack assembly. REGULARLY FURNISHED: Cast brass valve with red handwheel. Female NPT inlet and outlet. 300 PSI120.6 bars. Model 4070 ...... ............... 1'c'13.8cm Size 4075 .....................23 16.4 cm Size ADJUSTABLE PRESSURE RESTRICTING ANGLE VALVE FEMALE x MALE I DOUBLE FEMALE FUNCTION: Used with a fire hose rack assembly or as a fire dept outlet connection. Water pressure is controlled by adjustable flow restriction. If full flow is required, the restriction may be overridden. REGULARLY FURNISHED: Cast brass valve with red handwheel with pressure restricting feature. Female NPT inlet x male hose thread outlet. 175 PSI/12 bars rated. Furnished with field setting chart. Model 4080 .....................1 V'13-8 cm Size 4085 .....................2'1'16.4 cm Size SPECIFY: Thread OPTIONAL FINISHES: —B Polished Brass —C Rough Chrome Plated —D Polished Chrome Plated D in FUNCTION: Used with a fire hose rack assembly. Water pressure is controlled by adjustable flow restriction. If full flow is required, the restriction may be overridden. REGULARLY FURNISHED: Cast brass valve with red handwheel with pressure restricting feature. Female NPT inlet and outlet. 175 PSI/12 bars rated. Furnished with field setting chart. Model 4090 .....................1X 13.8 cm Size 4095 .....................2X'16.4 cm Size Double Female shown POTTER ROEMEIR 4 r � i�'lAE3JQY�tiTEC�'TifIW �J _.. Page 48 Clbsed Open UL AFM A$ C C U E � ^ _ ., + em" • , cm ., sm cra emw. ;I"'ein•x 'f 'h YES No Th 3h 61h Th 2'h 2 5.7 8.9 16.5 19 6.4 5 YES NO 8'92 41 29'71 8'92 69 127 D in FUNCTION: Used with a fire hose rack assembly. Water pressure is controlled by adjustable flow restriction. If full flow is required, the restriction may be overridden. REGULARLY FURNISHED: Cast brass valve with red handwheel with pressure restricting feature. Female NPT inlet and outlet. 175 PSI/12 bars rated. Furnished with field setting chart. Model 4090 .....................1X 13.8 cm Size 4095 .....................2X'16.4 cm Size Double Female shown POTTER ROEMEIR 4 r � i�'lAE3JQY�tiTEC�'TifIW �J _.. Page 48 POTTERROEMER Page 4-9 HoBE vALvEs In STRAIGHT GLOBE FEMALE x MALE I DOUBLE FEMALE FUNCTION: Used with a fire hose assembly or as a fire dept outlet connection. REGULARLY FURNISHED: Cast brass valve with red handwheel. Female NPT inlet x male hose thread outlet. Model 4110 ....................1'/z 13.8 cm Size 4115 ...................2'1'16.4 cm Size SPECIFY: Thread i _13 IF -A- -F FUNCTION: Used with a fire hose rack assembly or as a drain valve. REGULARLY FURNISHED: Cast brass valve with red handwheel. Female NPT inlet and outlet. Model 4119 ....................3/'11.3 cm Size 4120 ...................1'1'/3.8 cm Size` 4125 ...................2X"16.4 cm Size SPECIFY: Thread OPTIONAL FINISHES: - B Polished Brass - C Rough Chrome Plated - D Polished Chrome Plated VARIATIONS: Extended stem up to 24"161 cm SPECIFY: Length 5 ClosedOPen �..s' p E , �'rma w m in 1n, 1a m sm em sni•� �pnac 2 4 4V= 1 Th 2'h 0.3 5 10.2 10.7 2.5 8.5 5.7 2'h 313 7'/, 874 3 5'/. 57: 238 , 6.4 8.9 18.4 20.9 76 14.6 14 9 4,,K h 3'h 1 5 1 10'/. 1 VA 3'h 8'/. 7 K ` 4 8.9 1 12.7 1 26 28.5 8.9 20.9 17.8 FUNCTION: Used as a fire dept outlet connection. Designed to prevent unauthorized use. REGULARLY FURNISHED: Cast brass valve with brass pentagonal operating nut. Female NPT inlet x male hose thread outlet. Brass cap and chain. 300 PSI720.6 bars. Model 'IBI' 4141 .....................114"13.8 cm Size 4142 .....................2X"16.4 cm Size 4143 . ..4" x 2X"110.2 X 6.4 cm Size SPECIFY: Thread r Size Closed Open Listed ;i m , .•,fp ..,ane m in sm a ,...r _. . ='YES YES 3 IVa 61h Th 2 7.6 2.8 16.5 1929.2 5 VES YES 4 1'/e 91 11'3 8 d r 10.2 2.8 24.1.1 6.9 39.3 6.9 4a2Y1 No No 7 1'h 13'/s 15'h 3'/: 1d.2r84 , 17.7 2.8 34.2 8.8 AOiTER RiOF'MER P DOUBLE FEMALE TO FEMALE SWIVEL MALE REDUCING x FUNCTION: Used to connect two male hose FUNCTION: Used to reduce or change Ap threads. threads. �% Ar u°°� REGULARLY FURNISHED: Brass pin lug REGULARLY FURNISHED: Brass with pin _ swivels with female threads. lugs with female thread larger than male thread. s� A 00 B A�_ B Female Female Female Male M Model 2805 ........1X'13.8 an thru 2X"/6.4 cm Model 2810 ..........X"�i.s cm thru Y/7.s cm SPECIFY: Size and threads SPECIFY: Size and threads VARIATIONS: SUFFIX -RL Rocker Lug 45?1 eag`','r�� 6Y NAFo FEMALE TO MALE FUNCTION: Used to reduce or change threads. REGULARLY FURNISHED: Brass hexagon - type with female threads on one end and male on other end. A B Female Male Model 2815 .........'/<" i1.9 cm thru 4"/102 cm SPECIFY: Size and threads VARIATIONS: SUFFIX -PL Pin Lug -RL Rocker Lug MALE TO FEMALE FUNCTION: Used to reduce or change threads. REGULARLY FURNISHED: Brass hexagon - type with male threads on one end and female on other end. FEMALE TO FEMALE FUNCTION: Used to change threads. REGULARLY FURNISHED: Brass hexagon - type with female threads on both ends. A B Female Female Model 2820 ..........X'/1.9 cm thru 3"17.6 cm SPECIFY: Size and threads (Both ends the same size). MALE TO MALE FUNCTION: Used to reduce or change threads. REGULARLY FURNISHED: Brass hexagon - type with male threads on both ends. A B A B Male Female Male -� �- Male Model 2825 ........% /1.9 cm thru 4X/11.4 an Model 2830 ........'/< I1.s cm thru 4X'711.4 cm SPECIFY: Size and threads VARIATIONS: SUFFIX -RL Rocker Lug MALE TO FEMALE FUNCTION: Used to reduce or change threads. REGULARLY FURNISHED: Brass hexagon -type bushing with male thread larger than female thread. A B Male Female Model 2835 ..........3<'11.9 cm thru 3"17.6 cm ADAPTER SIZES AVAILABLE OPTIONAL FINISHES: 1s j cmr 6 A m/ cm B A m/ 4w, , �B Polished Brass � � ,. -.__ _ � . .. , � ..<. r ..:.. ` -'/4 _ ..� ; : ;K" 1C Rough Chrome Plated 'h x �/ 2...X, 2 2'/z X wz 11/2 X 3/4 2 X 3 X J'h 3 X 3 g 1.9 1.9 3.8 1.9 5 1.9 5 5 6.4 3.8 7.6 3.8 76 7.6 -D Polished Chrome Plated 1 '/4 11h 1 2 1 2v: 1/4 272 2 3 2 4 4 2.5 X 1.9 3.8 X 2.5 5 X 2.5 6.4 X 1.9 6.4 X 5 7.6 X 5 10.2 X 10.2 1 X 1 1'/: 1'/= 2 1'h 2'/� 1 2'/: 2'/s X X X X 3 2'/: X 4'/: 4 X 2.5 2.5 3.8 3.6 5 3.8 6.4 2.5 6.4 6.4 76 6.4 11.4 10.2 Page 2-c5 NOTE ALWAYS INDICATE HOSE THREAD REQUIREMENTS'yAU d�mensions in ;English andJLlelnG ., . .,.,,�T . ,.s , CABINET I BRASS RACK ESCUTCHEONS NIPPLE FUNCTION: Used to conceal pipe entry into cabinet. Model 2750 .......114"/3.8 cm Stamped steel, polished chrome plated. Model 2751 .......214"/6.4 cm White, high -heat polystyrene. FUNCTION: Used to support hose rack from valve and adapt pipe thread to hose thread. REGULARLY FURNISHED: Cast brass hexagon -type hose rack nipple with male NPT x male hose thread. Model 2755 .......114"/3.8 cm Model 2756 .......2X" /6.4 -cm OPTIONAL FINISHES: —B Polished Brass —C Rough Chrome Plated —D Polished Chrome Plated SPECIFY: Thread BRASS ADJUSTABLE PRESSURE RESTRICTING DEVICE FUNCTION: Used to reduce water pressure at hose line by restricting flow. Removable break- able link allows restriction to be overridden. REGULARLY FURNISHED: Cast brass finish, female pin lug swivel hose thread x male hose thread adjustable pressure restricting device, furnished with field setting chart. Model 2765 ....................114 /3.8 cm Model 2766 U/L .................23,4"/6.4 cm OPTIONAL FINISHES: —B Polished Brass —C Rough Chrome Plated —D Polished Chrome Plated SPECIFY: Thread BRASS AUTOMATIC DRAIN VALVE FUNCTION: Used to prevent water damage to hose due to valve leakage. REGULARLY FURNISHED: Cast brass female pin lug swiv- el hose thread x male hose thread drain valve with ball seal, activated at 3 PSI/.2 bars. Model 2760 .......1 x"/3.8 cm OPTIONAL FINISHES: —B Polished Brass —C Rough Chrome Plated —D Polished Chrome Plated SPECIFY: Thread BRASS RESTRICTING DISC FUNCTION: Used to reduce water pressure at hose line by restricting flow. Brass disc with orifice size as ordered. Model 2770 ....................1 36"/3.8 cm Model 2771 ....................2'/6.4 cm SIZING INFORMATION: A = 0.0425 Q A2 = Orifice Size in Square Inches Q = Flow in GPM P' = Inlet Pressure PZ = Required Outlet Pressure .0425 x GPM/ipm divided by square root of differ- ence between inlet pressure and required outlet pressure results in orifice size, in square inches. SEMI-AUTOMATIC HOSE RACK FUNCTION: Used to store hose ready for one- man operation of assembly. Water retention device stops water at first fold, after valve is open, until preceding folds are free of rack. Model 2792 .... For Use With 114"/3.8 cm Valve and 114"/3.8 cm Model 2915 Hose Model 2794 .....For Use With 214"/6.4 cm Valve and 1 W'/3.8 cm Model 2915 Hose REGULARLY FURNISHED: U/L listed t FM u approved pin -type hose rack, powder -coated with an electrostatically -applied, thermally -fused, red polyester finish; welded all - steel cover with water retention device and com- bination nozzle clip. Type of rack as selected by model number. Pins provided to accommodate only the maximum length hose allowable. OPTIONAL FINISH: —D Polished Chrome Plated Note: Listing valid only when appropriate Potter -Roemer hose is used. POTTER ROEMER yY ftA€PAOTT:GTrCJItl'trilti Pt �„� Page 2-4 PID?TER ROEMER aOCYM h - Ai� =1=pq■ Page 5-7 STORZ FIRE DEPT INLET CONNECTIONS FUNCTION: Used as an auxiliary inlet connection to supplement the fire protection water supply. Provides a range from 50011892 to 100013785 GPM/ipm per inlet. A Storz connection provides a means of rapid supply through large diameter hose (LDH). REGULARLY FURNISHED: Hard coated aluminum with Storz on one end and female national pipe thread on the other. SPECIFY: Model number for size X795 III '' 4' STORZ X 4" NPT 10.2 cm 10.2 cm i�'T95 5' STORZ X 4' NPT D2 K3 E r....;...:, : 12.7 cm 10.2 cm 5Y95 03 ; r ` 6' STORZ X 4" NPT 15.2 cm 10.2 cm 4" STORZ X 6" NPT X79 D z= 10.2 cm 15.2 cm rx t27cmTORZ152cmPT �, 5795 05 6' STORZ X 6' NPT 15.2 cm 15.2 cm STORZ BLIND CAPS WITH CHAINS ==s■ 4' STORZ 10.2 cm 5' STORZ 12.7 cm 6' STORZ 15.2 cm -. �,.. Call for availability of other k 5 ■ STORZ configurations