SEPTIC TANK
X
Bottom of tank hole has 6" stone base
X
Weep hole plugged
X
gallon tank has been installed
(H-10 or H-20) (monolithic or 2 piece)
X
Water tightness of tank has been achieved
Visual or Vacuum Test or Water held for 24hrs)
X
Inlet tee installed, under access port
❑
Outlet tee (gas baffle or effluent filter) installed, under
access port
X
inch cover to within 6" of final grade installed over
one access port, must be over outlet of tank if effluent
filter is present Manhole installed
❑
Hydraulic cement around inlet OK & outlet
Comments:
PUMP CHAMBER NO Pump Chamber
❑ Bottom of tank hole has 6" stone base
❑ Weep hole plugged
❑ gallon Pump Chamber installed
(H-10 or H-20) (monolithic or 2 piece)
❑ Inlet tee installed, under access port
❑ Pump(s) installed on stable base
❑ Alarm float working
❑ Pump On/Off float working
❑ Drain hole in pressure line
❑ inch cover to within 6" of final grade installed over
one access port
❑ Water tightness of tank has been achieved
Visual or Vacuum Test or Water held for 24 hrs
❑ Hydraulic cement around inlet & outlet
Comments: