HomeMy WebLinkAboutMiscellaneous - Exception (450)Pressure dosed 11. if flow >= 2,000 gpd - 254(1)(a) & 254(2)(a) Cycles per day is consistent with chamber volume - 23 1 Volume calculations include flowback volume - 2') 1(2) 24 hour storage capacity above pump on elevation - 231(2) Number of pumps: 2 if system serves >2 dwelling units - 231(6) Capacity of pump(s) - gpm @ ' TDH - 226(4)(r) Pump can pass 1 1/4 "solids (minimum) - 231(7) Pump controls specified - 220(4)(r) Alarm equipment specified - 231(2) Alarm is in building and powered on separate circuit from pump - 2') 1(9) Pump sequence correct (off -lead on -lag on-alan-n on) - 231(8) Pump performance curves included - 220(4)(r) - Manual operating switch - NA 12.01 Check valve, bleeder hole - NA 12.01 1 childproof, 24" riser/manhole to final grade - 2'31(5), Soil compaction beneath pump chamber specified (if soil is non-native) - 221(2) 6"of <=3/4"stone beneath chmbr. specified - 221(2) & 228(1), Buoyancy calculations if chamber is at or below water table - 221(8)@ 9" of cover over chamber (minimum) - 228(1) H- 10 loading (min.) - H-20 if traffic - 226(')); Chamber is watertight - 221 (1) ` Top of chamber <=36" below grade - 221(7) Leaching Facility (general - complete for all designs) OK Problem N/A 50% larger if garbage disposal - 240(4) Trenches to be used whenever possible - 240(6) No vehicle or imperv. area above 11. unless unavoidable - 240(7); NA 13.02 - Vented if under impervious cover - 241 (1) Vented through same pipes as distribution system - 241 (1)(a) Vent protected from precipitation/animal entry - 241 (1)(b) Vent is -placed beyond traffic or impervious area - 24 1 (1)(c) All lines connected to vent if bed or trenches - 241(1)(d) - 9" cover over peastone - 240(9) Reserve area provided (new construction) - 248(1) Reserve 4' from primary leach area – NA 9.04 4' (5' if perc rate <=2 MPI) separation to g.w. - 212(a) & (b) 4' (down to T with variance or I/A - upgrades only) of natural soil under U. GW separation is adjusted to highest existing grade if facility cuts into a hillside Pipe slope minimum of 0.005 - 251(9) Require 5' removal and replacement if in fill - 255(5) Top of leach facility <= 36" below grade - 221(7) �1 Final grade over 11. minimum 0.02 ft/ft -240(10) Surface & subsurface drainage away from l.f. - 240(l 1) & 245(5) Minimum design flow 440 gpd without deed restriction – NA 13.01 - 3:1 slope where grading required - 255(2) Toe of fill slope stops E from property line or swale installed - 255(2) Impermeable barrier if < 3:1 slope or < 15 feet to–3:lslope - 255(2) Impermeable barrier/retaining wall poured concrete – NA 9.02 ` Retaining wall stamped by P.E. - 255(2)(b) �—' Top of retaining wall >= top of peastone elevation - 255(2)(f) ---' 10' offset from edge of leach facility to edge of ret. wall - 255(2)(g) Perc test(s) done in most restrictive layer - 104(2) Perc test 4' below leaching elevation – NA 7.06 Design flow listed and required/provided leach area given - 220(4)(f) Leach pipes SCH40 PVC – NA 10.01 -� Leach pipes minimum 4" diameter except for dosed system – NA 14.04 Leach lines capped, vented, or connected together - 251(9) Pressure dosing guidance followed if pressure distribution - 254(2)(c ), Pressure dosing required over 2,000,gpd or with I/A remedial use - 231(1) ti '•6 a Leaching Trenches (Check here if not present: ) OK Problem N/A Number of trenche : - Minimum of 2 tr fiches - NA 9:01(2) Depth of trenc s (max eff. 2'): Width of tre ches (2' min., 4' max.): . Length of enches (100' max.): -247(l) - 251 (1)(b) - 25 1 (1)(a) Trench are vented (when > 50' - 251 (11) Tren es follow contour lines 251(2) Tr ch spacing 3 times eff five width or depth mi. fill or reserv;ea etwee enches, 10' min. - NA 1 Available leachea g en (Min. 500 s.f.) - NA 9.0 Bottom = x x#_ Sidewall x D x # Effective leach given 251 (1)(d) 14.03 s.f. x2= s.f. t-� Effec a area = total area f. x LTAR = Effective ea is >= design flow of faeflity being served 2"of 1/8 - 1/2" 2x washed peastot}e - 247(2) Trench depth of 3/4" to 1 1/2" double washed stone - 247(1) Leach Fields (Check here if not present: OK Problem N/A g/day Final Grading OK Problem N/A - Slope over leach area minimum of 0.02 feet/foot - 240(10) Grading shall divert drainage away from leach area - 240(l 1) =l Grading slopes away from dwelling 5/24/01 f./office/forms/tonackltr.doc rol Number of fields: (need dosing chamber if > 1, 231 (1)) ��- Length (100' max.): - 252 (2)(b) Width: �,- Total area: L x W = s. f. Minimum 900 square feet - NA 9.01(1) Distribution lines connected with solid pipe - NA 15.01 Effective leach area given Loading factor: Effective area = total area s.f x LTAR = g/dav Effective area is >= design flow of facility being served Minimum of two distribution lines - 252(2)(a) " 6' line separation (max.) - 252(2)(d) 4' maximum separation from edge of field to line - 252(2)(e) 10' minimum separation between adjacent leach fields - 252(2)( f) Between 6" and 12" of 3/4 - 1 1/2" stone beneath field - 252(2)(g) & 247(2) 2"of 1/8"-1/2" 2x washed peastone.- 247(2) Final Grading OK Problem N/A - Slope over leach area minimum of 0.02 feet/foot - 240(10) Grading shall divert drainage away from leach area - 240(l 1) =l Grading slopes away from dwelling 5/24/01 f./office/forms/tonackltr.doc rol