Loading...
HomeMy WebLinkAboutMiscellaneous - Exception (558)MASSACHUSETTS ELECTRIC CO. MERRIMACK VALLEY DIST HDQTRs CONTINGENCY AND EMERGENCY RESPONSE PLAN dMassachusetts Electric A New England Electric System company December 21, 1992 Mr. Gayton Osgood Director North Andover Board of Health 120 Main Street North Andover, Massachusetts 01845 Massachusetts Electric Company 1 101 Turnpike Street North Andover, Massachusetts 01845-6109 Telephone: (5081683-9511 No re: Massachusetts Electric Company Contingency and Emergency Response Plan Dear Mr. Stanley: In accordance with Massachusetts hazardous waste regulation 310 CMR 30.522, enclosed is the Contingency and Emergency Response Plan (Plan) for the Massachusetts Electric Company facility located at 1101 Turnpike Street, North Andover, Massachusetts. This Plan presents procedures implemented at the facility to prevent and minimize hazards to human health or the environment from fires, explosions, or releases of hazardous waste/material or its constituents to air, soil, or surface water. Please review the Plan to become more familiar with our facility and our emergency procedures and retain it for future reference. If the Plan is changed or amended, the revisions will be transmitted to you. If you have any questions regarding this Plan, please contact Sabrina L. Lewis, Environmental Engineer at (508) 683-9511, extension 1379. Sincerely, 4 Dennis E. Snay Vice President & District Manager cc: J. H. Dickson J. M. Kwasnik D. J. Mahoney R. A. Yanco No Enclosures 0. 4 OEM COMMONWEALTH OF MASSACHUSETTS mm EXECUTIVE OFFICE OF ENVIRONMENTAL AFFAIRS DEPARTMENT OF ENVIRONMENTAL PROTECTION'S METROPOLITAN BOSTON - NORTHEAST REGIONAL OFFICE ARGEO PAUL CELLUCCI TRUDY COXE Governor Secretary Noy 13 1997 DAVID B. STRUHS Commissioner Massachusetts Electric Co. RE: NORTH ANDOVER 1101 Turnpike Street 1101 Turnpike St. N. Andover, Massachusetts 01845 RTN #3-15659 RELEASE NOTIFICATION & Attn: Ms. Maureen Beecy NOTICE OF POTENTIAL RESPONSIBILITY; MGL c. 21E & 310 CMR 40.0000 Dear Ms. Beecy: On October 28, 1997 at 4:50 p.m., the Department received oral notification of a release/threat of release of oil/hazardous material at the subject location. The Department has reason to believe that the release/threat of release which was reported is or may be a disposal site as defined in the Massachusetts Contingency Plan (MCP), 310 CMR 40.0000. The Department also has reason to believe that you -(as used in this letter "you" refers to Massachusetts Electric Co.) are a Potentially Responsible Party (PRP) with liability under Section 5A of M.G.L. c. 21 E. This liability is "strict" meaning that it is not based on fault but solely' on your status as owner, operator, generator, transporter, disposer or other person specified in Section 5A. This liability is also "joint and several", meaning that responsible parties are liable for all response costs incurred at a disposal site even if there are other liable parties. The Department encourages parties with liabilities under M.G.L. c. 21E to take prompt action in response to releases and threats of release of oil and/or hazardous material. By taking prompt action, you may significantly lower your assessment and cleanup costs and avoid the imposition of, or reduce the amount of, certain permit and annual compliance fees for response actions payable under 310 CMR 4.00. Please refer to M.G.L. c. 21 E for complete description of potential liability. GENERAL RESPONSE ACTION REQUIREMENTS The subject site shall not be deemed to have had all the necessary and required response actions taken unless and until all substantial hazards presented by the site have been eliminated and a level of No Significant Risk exists or has been achieved in compliance with M.G.L. c. 21E and the MCP. In addition, the MCP requires persons undertaking response actions at disposal sites to perform Immediate Response Actions (IRAs) in response to "sudden releases", Imminent Hazards and Substantial Release Migration. Such persons must continue to evaluate the. need for .IRAs and notify the Department immediately if such a need exists. 10 Commerce Way • Woburn, Massachusetts 01801 9 FAX (781) 932-7615 • Telephone (781) 932-7600 0 TDD # (617) 932-7679 Massachusetts Electric Co. Page -3- It is important to note that you must dispose of any Remediation Waste generated at the subject location in accordance with 310 CMR 40.0030 including, without limitation, contaminated soil and/or debris. Any Bill of Lading accompanying such waste must bear the seal and signature of an LSP or, if the response action is performed under the direct supervision of the Department, the signature of an authorized representative of the Department. If you have any questions relative to this notice, you should contact the undersigned at the letterhead address or (617) 932-7600. All future communications regarding this release must reference the Release Tracking Number (RTN #3-15659) contained in the subject block of this letter. KN/fc Sincere y, Ki sley Ndi Chief, Notification Branch Emergency Response cc: Fire Dept., 124 Main St., N. Andover, MA 01845 Board of Health, Town Bldg., N. Andover, MA 01845 DEP data entry/file Attachment: Release Notification & Notification Retraction Form; BWSC - 103 MASSACHUSETTS ELECTRIC COMPANY MERRIMACK VALLEY DISTRICT HEADQUARTERS CONTINGENCY AND EMERGENCY RESPONSE PLAN DECEMBER 1992 TABLE OF CONTENTS 1.0 Introduction 1-1 1.1 Purpose of the Plan 1-1 1.2 Location 1-2 1.3 Amendments to the Plan 1-2 2.0 Arrangements with Local Authorities 2-1 3.0 Description of Hazardous Materials 3-1 3.1 Hazardous Waste 3-1 3.1.1 Waste Oil and Waste Oily Debris 3-1 3.1.2 Waste Oils Containing PCBs and PCB -Contaminated Debris 3-1 3.1.3 Waste Solvents and Solvent - Contaminated Debris 3-1 3.2 Bulk Quantities of Hazardous Materials 3-2 3.2.1 Diesel Fuel 3-2 3.2.2 Motor Lubricating Oil 3-2 3.2.3 Gasoline 3-2 3.2.4 Hydraulic Fluid 3-2 3.2.5 Mineral Oil Dielectric Fluid (MODF) 3-2 4.0 Preparedness and Prevention 4-1 4.1 Procedures to Prevent Incompatible Chemical and Waste Mixing 4-1 4.2 Hazardous Waste Handling Operations 4-1 4.3 Equipment for Power Failures 4-2 4.4 Inspections and Preventative Maintenance 4-2 4.5 Prevention of Hazardous Chemical Exposures to Employees 4-3 4.6 Fire Prevention 4-3 4.7 Spill Prevention 4-4 4.8 Prevention from Flooding 4-5 5.0 Site Security and Control 5-1 6.0 Emergency Response Personnel 6-1 6.1 Emergency Coordinator Designation 6-1 6.2 Emergency Coordinator Responsibilities 6-1 6.3 Roles in an Emergency 6-2 6.4 Training 6-2 6.4.1 Emergency Coordinators and Other Personnel Handling Hazardous Waste 6-2 6.4.2 Other Personnel 6-3 i TABLE OF CONTENTS (Continued) 7.0 Emergency Equipment 7.1 Communication Systems 7.2 Firefighting Equipment 7.3 Spill Control Equipment 7.4 Personal Protective Equipment 8.0 Emergency Response Procedures 8.1 Initial Response 8.2 Emergency Coordinator Responsibilities 8.2.1 Initial Response 8.2.2 Verbal Notifications 8.2.3 Site Remediation 8.2.4 Post Site Remediation 8.2.5 Post Site Remediation Written Notification 8.3 Fire and/or Explosion 8.4 Flood Response 8.5 Spill Procedures 8.6 Bomb Threat Response 8.7 Securing the Site 8.8 Decontamination 8.9 Critique of Response and Follow-up 9.0 Evacuation 10.0 Emergency Medical Treatment and First Aid 11.0 Recordkeeping 11.1 Emergency Release Reports 11.2 Manifests 11.3 Exception Reports 11.4 Land Disposal Restriction Notifications 11.5 Accident Reports LIST OF TABLES 1. Emergency Coordinators 2. Spill Cleanup Equipment 3. Public Agency Telephone Numbers and Addresses LIST OF FIGURES 1. Site Plan 2. Hazardous Substances and PCB Release Report Form ii 7-1 7-1 7-1 7-1 7-1 8-1 8-1 8-1 8-1 8-2 8-4 8-5 8-5 8-7 8-7 8-7 8-8 8-8 8-8 8-9 9-1 10-1 0 0 0 TABLE OF CONTENTS (Continued) APPENDICES A. Letters of Transmittal of Contingency Plans to Emergency Response Agencies and Local Authorities B. Description of vendor Capabilities and Letters of Commitment C. Hazardous Material Cleanup Standards D. Environmental Files E. Emergency Response Procedure F. Emergency Action Plan G. Emergency Release Notification Chemical Fact Sheets iii MASSACHUSETTS ELECTRIC COMPANY MERRIMACK VALLEY DISTRICT HEADQUARTERS CONTINGENCY AND EMERGENCY RESPONSE PLAN 1.0 Introduction The Merrimack Valley District Headquarters is a Massachusetts Electric Company (MEC) facility located at 1101 Turnpike Street, North Andover, Massachusetts, 01845. The Company's principle business is the distribution and retail sale of electricity. MEC is a wholly-owned subsidiary of New England Electric System (NEES). This facility is registered with the Massachusetts Department of Environmental Protection (DEP) as a small quantity generator of federally -regulated hazardous waste and a large quantity generator of state -regulated waste. The facility's U.S. Environmental Protection Agency (EPA) identification number is MAD030833966. 1.1 Purpose of the Plan The Contingency and Emergency Response Plan (Plan) presents procedures implemented at the facility to prevent and minimize hazards to human health or the environment from fires, explosions, or any unplanned sudden or non -sudden release of hazardous waste/material or hazardous waste/material constituents to air, soil, or surface water. This Plan documents the MEC Merrimack Valley District Headquarters' implementation of the requirements set forth in the Massachusetts Department of Environmental Protection (DEP) hazardous waste regulations 310 CMR 30.520. Additionally, it fulfills the requirements of Occupational Safety and Health Administration (OSHA) 29 CFR § 1910.120 (q) and § 1910.38. Implementation of the Plan is based on an evaluation of the potential or actual threat to employee and public health, safety, and welfare or the environment. The evaluation is made by the Emergency Coordinator at the scene and is based on the following criteria: 1. Nature of the release. The degree of hazard of the material released is evaluated with regard to fire, explosion, reactivity, and toxicity potential. 2. Location of the release. The extent of confinement and the potential for mitigation is considered. 3. Extent of the release. The the potential for ongoing considered. 1 - 1 total quantity released and or additional releases is Contingency and Emergency Response Plan Introduction 1.2 Location December 1992 The Contingency and Emergency Response Plan is located in the District Superintendent's Office. Duplicate copies have been distributed to facility management and other key emergency response personnel and are available for inspection by all facility employees. Copies have also been submitted to various state emergency response agencies and local authorities. Copies of the letters of transmittal are included as Appendix A. 1.3 Amendments to the Plan The Division Environmental Engineer has the authority and responsibility to change and amend the Plan. The revisions are immediately transmitted to personnel and organizations requiring notification of such action. The Plan shall be reviewed and immediately amended in the event of any of the following occurrences: 1. A facility permit revision; 2. Plan failure during an emergency; 3. Emergency response personnel change; 4. Facility operations or maintenance procedure change; 5. Existence of other circumstance which indicate the need for a change in the Plan. 0 1 - 2 Contingency and Emergency Response Plan December 1992 2.0 Arrangements with Local Authorities The Merrimack Valley District Headquarters has made arrangements with outside organizations that may be contacted when necessary. The agencies below are available to provide assistance in the event of an emergency: 1. Clean Harbors of Braintree, Inc. (800) OIL -TANK 2. Ransom Environmental Consultants (508) 465-1822 3. North Andover Fire Department (508) 689-7777 4. North Andover Police Department (508) 683-1212 5. Lawrence General Hospital (NE CMED) (508) 685-0224 Clean Harbors, Inc. has -agreed to provide this facility with 24 hour a day emergency hazardous waste cleanup assistance. Refer to Appendix B for a description of their capabilities and a letter of commitment. In addition, a copy of the Contingency and Emergency Response Plan has been forwarded to the agencies listed below: 1. Massachusetts Department of Environmental Protection (DEP), Northeast Region; 2. Local Emergency Planning Committee, c/o the North Andover Fire Department; and 3. North Andover Board of Health. Each of these organizations/ agencies have been provided a copy of the Plan which will familiarize them with the layout of the facility, properties of hazardous waste handled at the facility, hazards associated with such wastes, places where facility personnel would normally be working, entrances to and roads inside the facility, and possible evacuation routes. Copies of the associated transmittal letters are included in Appendix A. 2 - 1 Contingency and Emergency Response Plan December 1992 3.0 Description of Hazardous Materials Hazardous materials stored and/or generated at the facility include hazardous wastes and bulk quantities of hazardous materials. Each is discussed below. 3.1 Hazardous Waste The following hazardous wastes are generated at the facility: 3.1.1 Waste Oil and Waste Oily Debris Waste oils generated at the facility include Mineral Oil Dielectric Fluid (MODF) with no detectable polychlorinated biphenyl (PCB) content resulting from the drainage of electrical equipment, and lubricating and motor oils primarily generated from vehicle maintenance activities. These wastes may be contained in 55 gallon drums and/or in an underground storage tank located outside of the Vehicle Maintenance Garage. Oily debris such as contaminated rags and absorbent are generated from spill cleanups and normal facility maintenance activities. 3.1.2 Waste Oils Containing PCBs and PCB -Contaminated Debris PCB wastes may include PCB -contaminated insulating oil and PCB -contaminated debris. The waste PCB - contaminated insulating oil may be contained in 55 gallon drums, aboveground tanks, or undrained, electrical equipment designated for disposal. The PCB -contaminated debris may be generated from spill cleanups and/or normal maintenance activities. 3.1.3 Waste Solvents and Solvent -Contaminated Debris Waste solvents generated at the facility may include petroleum based solvents such as mineral spirits, spent refrigerants generated from building maintenance activities, or materials containing chlorinated solvents such as 1,1,1 - trichloroethane. The solvent debris is primarily contaminated rags generated from normal maintenance activities. Paint -related waste materials containing solvents may also be generated at the facility periodically. 3 - 1 Contingency and Emergency Response Plan Description of Hazardous Materials December 1992 3.2 Bulk Quantities of Hazardous Materials The following hazardous materials are used and stored in bulk quantities at the facility. 3.2.1 Diesel Fuel Up to 10,000 gallons (69,000 pounds) of diesel fuel oil are stored in an underground storage tank located outside the Vehicle Maintenance Garage. The fuel is for use in company vehicles. 3.2.2 Motor Lubricating Oil Motor lubricating oil is stored in two 500 -gallon underground storage tanks located along the south wall of the Vehicle Maintenance Garage. One tank is for waste lubricating oil and the other is for clean lubricating oil. 3.2.3 Gasoline Up to 10,000 gallons (60,000 pounds) of gasoline are stored in an underground storage tank located outside of the Vehicle Maintenance Garage. The gasoline is for use in company vehicles. 3.2.4 Hydraulic Fluid Hydraulic fluid is stored in three tanks located in the Vehicle Maintenance Garage. Two of the tanks, having capacities of 275 and 220 gallons, are located in the Solvent Bath Room located at the rear of the southern most service bay. The other tank has a 250 -gallon capacity and is located at the rear of the northern most service bay. This fluid is used as make-up for utility trucks and for operating the hydraulic lifts in the garage. 3.2.5 Mineral Oil Dielectric Fluid (MODF) MODF is contained in three (3) 500 -gallon aboveground storage tanks located inside the Transformer Room. The Transformer Room is located in the northwest corner of the Office Building, in the vicinity of the Transformer Maintenance Staging Area (see Figure 1). One tank contains new, no PCB MODF and the other two contain MODF that has been drained from electrical equipment. MODF is also contained in transformers and other electrical equipment stored at the facility. All of the electrical equipment is non-operating with the exception of the two facility transformers 3 - 2 Contingency and Emergency Response Plan Description of Hazardous Materials December 1992 located at the northeastern corner of the Office Building. The MODF-containing non-operating electrical equipment is stored in the following locations: * the Upper Transformer Storage Yard, * the Transformer Room, * the Transformer Staging Area, and * the Transformer Maintenance Staging Area. For information regarding the- properties and hazards of these materials, refer to the NEES Companies' Emergency Release Notification Chemcial Fact Sheets included as Appendix G. For a detailed description concerning bulk oil storage such as containment structures, operating procedures and practices, and measures to prevent releases of hazardous materials, refer to the NEES Companies' Hazardous Waste, Substances, and PCB Procedures Manual and the Merrimack Valley District Headquarters Spill Prevention Control and Countermeasure (SPCC) Plan. 3 - 3 Contingency and Emergency Response Plan December 1992 4.0 Preparedness and Prevention The Merrimack Valley District Headquarters facility is operated and maintained to prevent and minimize the possibility of any threat to public health, safety and welfare or to the environment. Preventative measures regarding structures, operating procedures and equipment are described below. 4.1 Procedures to Prevent Incompatible Chemical and Waste Mixing Each hazardous chemical and hazardous waste is kept in its own individual container which is handled and stored separately. The containers used for hazardous materials storage are maintained in good condition and are made of materials which are compatible with the. material being stored. Aisle spacing between containers is adequate to allow for regular inspection for damage and/or leaks. All hazardous waste containers are labelled in accordance with hazardous waste and DOT regulations. The labels properly identify the material by chemical name and state the hazards associated with the substance. All Massachusetts Electric Company employees involved in hazardous waste handling have received and/or are under the direct supervision of personnel who have received training regarding proper container handling, labelling, and incompatible hazardous materials. 4.2 Hazardous Waste Handling Operations All wastes which exhibit the characteristics of hazardous waste are handled as hazardous wastes. Hazardous wastes exhibit any or a combination of the following characteristics: * corrosive, reactive, ignitable and/or toxic; * listed by the state or federal government as hazardous waste; * waste oil; and/or * PCB -contaminated material. Hazardous waste is collected at the point of generation in 55 -gallon DOT -approved drums. Within three days of filling the container, the waste is transported to the hazardous waste storage area. Hazardous waste containers are kept closed, except when waste is being added to the container. Wastes, with the exception of PCB -contaminated material, are taken off-site within 90 days by a licensed hazardous waste transporter and delivered to a licensed hazardous waste treatment, storage and/or disposal facility (TSDF). PCB - 4 - 1 Contingency and Emergency Response Plan Preparedness and Prevention December 1992 contaminated waste materials are transported off-site within 30 days. Chlorinated solvent wastes are kept separate from other wastes and are manifested for disposal as land disposal restricted wastes. Indoor drum accumulation of hazardous waste occurs at the following locations: * Transformer Room (PCB debris); and * Vehicle Maintenance Garage (Oily debris). Outdoor drum storage of hazardous waste occurs at the following location: * Upper Transformer Storage Yard (Various); and * along the southern wall of the Vehicle Maintenance Garage (Oily debris). Tank accumulation of hazardous waste occurs at the following location: * Transformer Room (aboveground tank -PCB oil); and * Vehicle Maintenance Garage (underground tank -waste oil) . 0 Transformers designated for disposal are stored in the Upper Transformer Storage Yard. Refer to Figure 1 for locations of hazardous waste areas. 4.3 Equipment for Power Failures The facility is equipped with five emergency/backup generators, two of which are in the Vehicle Maintenance Garage, an additional two of which are located behind the Local Stores Building near the Transformer Room (see Figure 1), and one is located by the southwestern corner of the Office Building. The Vehicle Maintenance Garage maintains two gasoline -powered units;, one stationary and one portable 5 kW emergency generator. The other three units are 40, 75, and 115 kW propane -powered units and are maintained by Building and Office Services. 4.4 Inspections and Preventative Maintenance All hazardous waste areas are inspected weekly by the facility Hazardous Waste Coordinator or designee(s). Any discrepancies discovered during the inspections are recorded on the hazardous waste inspection form and corrected as soon as possible. Completed inspection reports are filed in the Stores Department, the Transportation Office, or the T&D 4 - 2 Contingency and Emergency Response Plan Preparedness and Prevention December 1992 District Superintendent's Office, depending on jurisdiction. The inspector checks to ensure the following: a. All applicable signs are in place and legible; b. the fire extinguishers are in place and functional; C. the inventory of safety and cleanup equipment is complete; d. all containers are properly labelled; e. all containers are -in good condition and not leaking; - f. hazardous waste containers are closed and have not been stored for greater than 90 days (or 30 days for PCB wastes) ; g. containment areas are free of spilled materials, precipitation, and debris; h. floors and outside areas are free of materials that may indicate the presence of leaks; i. tank seams, joints, piping, valves and equipment have no signs of deterioration and/or leakage; j. equipment and tank foundations and supports are free of cracks and/or deterioration; k. spilled materials are thoroughly cleaned, and; 1. adequate walkways and exit routes are maintained to allow for unobstructed movement of personnel, and spill control/decontamination and firefighting equipment. 4.5 Prevention of Hazardous Chemical Exposures to Employees All employees involved in hazardous substances handling are provided with proper protective equipment as discussed in the emergency equipment section below. Additionally, all employees are taught proper hazardous material handling procedures in their annual Hazard Communication Standard training and annual Hazardous Waste/PCB Training. 4.6 Fire Prevention The facility is designed and constructed to resist the ignition and propagation of fire through the use of non- combustible construction materials and other physical 4 - 3 Contingency and Emergency Response Plan Preparedness and Prevention December 1992 features which reduce the probability of ignition and spread of fire. In addition, all combustible materials are stored and utilized in a manner which minimizes the possibility of ignition. The facility is equipped with an automatic fire alarm system. Fire extinguishers are available throughout the facility and have been strategically located to reduce response time to outbreaks of fires. All fire extinguishers are inspected on a monthly basis by Building of Office Services and are recharged as necessary. Refer to Section IV of the Emergency Action Plan provided herein as Appendix F for the locations, sizes and types of fire extinguishers located throughout the facility. 4.7 Spill Prevention The only liquid waste stored outside are the MODF contained in the transformers and other fluid-filled equipment designated for disposal and an occasional drum of liquid waste. This waste is stored in a hazardous waste storage area located in the Upper Transformer Storage Yard. Precautions have been taken to minimize the potential for a spill and to control the migration of the material after the spill has occurred. To minimize the potential for a spill resulting from damaging the units while in storage, electrical equipment designated for disposal is stored on pallets with sufficient aisle space around them to allow easy movement amongst them. The Upper Transformer Storage Yard is bermed and sloped to prevent the uncontrolled migration of spilled materials outside of the containment area. The hazardous waste area within the Upper Transformer Storage Yard is also bermed and valved to prevent the migration of fluid out of the area and the surface is sealed to prevent infiltration into the ground. The bermed hazardous waste storage area is of sufficient area to contain well over 10% of the total volume of MODF stored and well over 110% of the possible volume of the largest transformer that would be stored in the area. The facility is equipped with materials such as spill kits and absorbent in sufficient quantities to contain and cleanup spills at the facility. Liquid waste transfers are performed in the Transformer Room and at the Vehicle Maintenance Garage, away from drains. Transfers are always under close control of the operator and the average amount of fluid transferred varies from less than 30 gallons per event for electrical equipment, to several thousands of gallons per event for diesel fuel and gasoline transfers. Stored liquid wastes are located away from drains. 0 4 - 4 Contingency and Emergency Response Plan Preparedness and Prevention December 1992 To mitigate against potential catastrophic gasoline or diesel fuel releases during transfers, the following safeguards have been put in place: * the vendor is responsible for ensuring that the tank is not overfilled; * MEC personnel monitor the transfer throughout the process. Spill material are readily available to address any immediate need; and * the underground storage tank(s) to which the material is being transferred are equipped with electronic monitors and alarms to notify facility personnel of a ..release... 4.8 Prevention from Flooding The facility is located on an elevated area; therefore, the likelihood of flooding is small. In the event of a flood watch or warning, the Emergency Coordinator ensures that all drums of material are removed from potential flood areas and that hazardous waste activities are suspended until all risks have passed. Contingency and Emergency Response Plan December 1992 5.0 Site Security and Control Security measures in place at the facility include a chain link fence along portions of the perimeter, restricted access through an electronic gate at the main entrance to the property, and closed circuit television cameras which are monitored during off -hours. Barbed wire extends above the chain link fence to deter vandalism. Facility lighting is sufficient to ensure the timely discovery of spills and to deter vandalism. In the event of a release, additional security is available to prevent accidental or unauthorized entry into the impacted area. People who are not involved in the control or cleanup of the release are denied access to the area. If necessary, the North Andover Police -Department is available to assist in controlling access to the impacted area. 5 - 1 Contingency and Emergency Response Plan December 1992 6.0 Emergency Response Personnel In the event of an emergency, facility personnel are prepared to respond appropriately. All personnel responding to an emergency are trained according to the level of response expected from that employee. A description of employee roles, responsibility. and training is presented below. 6.1 Emergency Coordinator Designation The Emergency Coordinators are responsible for coordinating area emergency response measures. An Emergency Coordinator is available at all times, 24 hours a day, 7 days per week, and is either on-site or able to reach the facility within one hour. The names, addresses and -home/work telephone numbers of the Primary and Alternate Emergency Coordinators are listed in Table 1. Whenever an imminent or actual emergency exists, the person discovering the emergency notifies the Emergency Coordinator or the Trouble Center who then notifies the Emergency Coordinator. If the Primary Coordinator is not available, attempts to contact an Alternate are made in the order put forth in Table 1 until an Emergency Coordinator is reached. All Emergency Coordinators have the authority to fulfill the provisions of this Plan. 6.2 Emergency Coordinator Responsibilities The Emergency Coordinator is responsible for oversight of the emergency response actions, including follow-up activities such as: * spill cleanup; * notifications to federal, state, and local agencies; and * evaluation of the effectiveness of the emergency response actions and the Plan. The Emergency Coordinator ensures that emergency equipment is maintained in good operating condition at the facility and that adequate space is available for emergency response actions. The Emergency Coordinators are thoroughly familiar with: * the layout of the facility; * the activities and operations at the facility; * the location and characteristics of the hazardous materials/wastes handled at the facility; 6 - 1 Contingency and Emergency Response Plan Emergency Response Personnel December 1992 the location and operation of all fire control, spill control and spill cleanup equipment; and * the location of all pertinent records within the facility. The Emergency Coordinators have reviewed and are familiar with this Plan and are responsible implementation. The Emergency Coordinators have all parts of the facility and have the authority whatever resources are necessary to carry out the of this Plan. 6.3 Roles in an Emergency 6.4 thoroughly for its access to to acquire provisions The Emergency Coordinator responding to the emergency is in charge of coordinating and controlling all of the operations at the site. When senior state or local officials or an emergency response contractor arrives at the site, the Emergency Coordinator works with the responders to coordinate activities. The Emergency Coordinator in charge identifies, to the fullest extent possible, all of the hazardous substances or conditions present and implements the appropriate emergency response operations. The Emergency Coordinator also limits the number of emergency response personnel at the site to those responders actively performing the emergency operations. Training All personnel that are involved in hazardous waste management or who are engaged in emergency response activities are required to successfully complete an annual training program that is designed in light of the duties and functions performed in their jobs and/or during an emergency situation. No employee handles hazardous waste or responds to an emergency unless he/she has completed or is under the direct supervision of supervisory personnel who have completed the appropriate training program. The levels of training are described below. 6.4.1 Emergency Coordinators and Other Personnel Handling Hazardous Waste The Emergency Coordinators and other personnel who may have to respond to an emergency or handle hazardous waste in their regular duties are trained to at least the "First Responder Operations Level" as described in 29 CFR Part 1910.120 (q). For additional information regarding hazardous waste training, refer to the Massachusetts Electric Company Hazardous Waste PCB Training Plan available at the T&D District Superintendent's Office. This training entails at 6 - 2 0 0 0 Contingency and Emergency Response Plan Emergency Response Personnel December 1992 least 8 hours of classroom and on-the-job training combined. The training session topics include: i. Implementation of the facility Contingency and Emergency Response Plan; ii. Spill control, containment and limited spill cleanup; iii. Emergency notification procedures; iv. Review of state and local emergency response plans; V. Identification of hazardous materials and basic hazard and risk assessment techniques; vi. The selection and use of proper personal protective equipment; vii. Basic toxicology of the hazardous wastes handled at the facility and the risks associated with them; viii. Safe handling of hazardous wastes; ix. Basic decontamination procedures; X. Evacuation procedures. 6.4.2 Other Personnel Other facility personnel who may have contact with hazardous waste or who are likely to witness or discover a release of hazardous material are trained to the "First Responder Awareness Level" as described in 29 CFR Part 1910.120 (q). For additional information regarding hazardous waste training refer to the Massachusetts Electric Company Hazardous Waste PCB Training Plan available in the T&D District Superintendent's Office. Training sessions at this level include the following topics: i. Emergency response notification procedures with emphasis on notification of the Emergency Coordinator or Trouble Center; ii. Definition of hazardous waste and hazardous materials; iii. Basic toxicology of hazardous materials handled at the facility and the hazards associated with them. 6 - 3 Contingency and Emergency Response Plan Emergency Response Personnel December 1992 iii. Safe handling of hazardous wastes; iv. Signs of the presence of a hazardous material during an emergency; V. Evacuation procedures. 0 6 - 4 Contingency and Emergency Response Plan December 1992 7.0 Emergency Equipment The emergency equipment presented below is available to the Merrimack Valley District Headquarters facility personnel. All emergency equipment is inspected weekly and maintained as required. Section IV of the Emergency Action Plan included herein as Appendix F shows the locations of the various emergency equipment available at the facility. 7.1 Communication Systems The facility is equipped with a general telephone system and an automatic fire alarm system. Telephones are located throughout the facility, including in the vicinity of the indoor hazardous waste accumulation areas, thus enabling immediate communication of the situation in the event of an emergency.. A list of telephone numbers of individuals and agencies to be contacted in the event of an emergency is posted by the telephone nearest each of the indoor hazardous waste accumulation areas. 7.2 Firefighting Equipment Wall -mounted portable fire extinguishers are located throughout the facility. Most of the fire extinguishers are dry chemical Type ABC of various sizes. All extinguishers are tested annually and are recharged as necessary. Refer to Section IV of Appendix F for the locations of the fire extinguishers and Section VII of Appendix F for a listing of the locations and types of fire extinguishers. 7.3 Spill Control Equipment A supply of spill control equipment is maintained in the Stores Department. Absorbent material such as DuraSorb is available for use along with brooms and shovels. Spill kits are also available. Each kit contains items such as boots, coveralls, neoprene gloves, brooms, shovels, handcleaner, marking tape, and absorbent materials. Clean empty DOT 17H drums are available for containerization of spill debris. A complete list of the spill kit components is included as Table 2. 7.4 Personal Protective Equipment Personal protective equipment including gloves, boots, coveralls, face shields, safety glasses, and hardhats is available to facility personnel. Selection of the appropriate personal protective equipment is based on factors such as: 7 - 1 Contingency and Emergency Response Plan Emergency Equipment December 1992 * the types of hazard(s) or suspected hazard(s) present; * the potential routes of entry which may result in employee exposure (inhalation, skin absorption, ingestion and skin or eye contact); * the ability of the equipment and/or materials to provide a barrier to the hazard(s). Additionally, the strength and durability of personal protective equipment is considered in relation to the task being performed. An eyewash station is located in the truckwash bay of the Vehicle Maintenance Garage. First aid kits are located in the various departments throughout the facility. J 7 - 2 Contingency and Emergency Response Plan December 1992 8.0 Emergency Response Procedures If an emergency arises, the facility is prepared to react quickly and in a manner that will protect the safety of all employees and all emergency response personnel, and that will mitigate potential adverse effects on the environment. The procedures presented below are followed during all emergency releases of hazardous substances. 8.1 Initial Response In the event of an emergency situation which has the potential for or actually results in a fire, explosion or uncontrolled release of a hazardous substance, a Supervisor is immediately notified and is informed of the exact location and nature of the upset. Upon receipt of the notification, the Supervisor performs the following tasks: a. Documents receipt of the call; b. Notifies the Emergency Coordinator and advises him/her of the situation. In the event the Emergency Coordinator cannot be immediately located, the Trouble Center is contacted who in turn notifies the Emergency Coordinator. If the Primary Emergency Coordinator is not available, the Trouble Center attempts to contact each Alternate in the order listed in Table 1 until an Emergency Coordinator is reached. Refer to Table 1 for the names and telephone numbers of the Emergency Coordinators. C. Under the direction of the Emergency Coordinator, the Supervisor or Trouble Center may notify the following: * the North Andover Fire Department; * additional emergency response personnel; and/or * District management. 8.2 Emergency Coordinator Responsibilities The Emergency Coordinator is responsible for the overall oversight of the emergency response activities, including initial response and subsequent cleanup, verbal and written notifications, and post -cleanup demobilization and spill response evaluation. Each is detailed below. 8.2.1 • Initial Response Upon receipt of the initial notification, the Emergency Coordinator takes the following actions: 8 - 1 Contingency and Emergency Response Plan Emergency Response Procedures December 1992 a. Either contacts or directs the Supervisor or Trouble Center to contact, the required management personnel, and additional 0 emergency response personnel and local agencies, as warranted; b. Immediately identifies the character, exact source and amount of material released; C. Determines whether or not normal activities must stop and if an evacuation is necessary; d. Directs the appropriate response actions described below that are required to minimize any hazards to human health or environment that may result from the release; 8.2.2 Verbal Notifications Based on the assessment of the nature and extent of the emergency, the Emergency Coordinator or his/her designee notifies the groups listed below. The telephone numbers presented in this section are restated in Table 3 for quick reference. a. All employees - in case of an evacuation. b. In case of fire or substantial release of a hazardous material/waste: North Andover Fire Department 689-7777 (emergency) 686-3812 (non -emergency) C. In case of an evacuation or need for community action: North Andover Police Department 686-1212 (emergency) 683-3168 (non -emergency) d. In case of injury(ies) resulting from the emergency: Lawrence General Hospital 685-0224 (emergency) 683-4000 (non -emergency) e. If the amount of hazardous material released is equal to or greater than the reportable quantity (RQ) which in the case of oil is ten (10) gallons if released onto land or any quantity if released into a waterway, the following notifications are made: 8 - 2 Contingency and Emergency Response Plan Emergency Response Procedures December 1992 * the Local Emergency Planning Committee (LEPC), c/o the North Andover Fire Department at 686-3812; and if during business hours, * the Massachusetts Department of Environmental Protection at (617) 935-2162; otherwise, * the State Police at (800) 525-5555. f. If the hazardous material released reaches a waterway, the National Response Center at (800) 424-8802 is notified within 24 hours of the release. g. In the event of: a release of hazardous material with a PCB content of over 50 ppm into water; or a release of 1 pound or more PCBs by weight into soil which is equivalent to: * One-tenth gallon of askarel, * 270 gallons of MODF with a concentration of 499 ppm or greater, or * 2,700 gallons MODF with a PCB concentration of 50 ppm or greater the Environmental Protection Agency (EPA) at (617) 565-3279 is notified within 24 hours. h. If cleanup assistance is needed, Clean Harbors at (800) OIL -TANK is contacted. i. If assistance in overseeing the cleanup operation to ensure that cleanup standards are met and/or in performing follow-up sampling and documentation is required, Ransom Environmental Consultants at (508) 465-1822 is contacted. j. The information supplied to the above agencies includes: i. The name and telephone number of the person making the notification; 8 - 3 Contingency and Emergency Response Plan Emergency Response Procedures December 1992 ii. Name and address of the facility; iii. Time and nature of the emergency; iv. Identity of the released material and quantity released; V. Extent of any injuries, and; vi. The potential hazards to human health or environment. 8.2.3 Site Remediation Once the emergency is under control, the Emergency Coordinator arranges for proper cleanup, collection and disposal of the recovered material and/or spill cleanup debris. Refer to Appendix C for cleanup standards. a. The released material is collected in its original form, if possible, and placed in an empty barrel, closed, sealed and properly labelled. The label includes the following information: * the words "Hazardous Waste", * the chemical identity of the waste, * the hazards associated with the waste, and * the date of containerization. The drums are moved to the facility hazardous waste storage area and disposed of in accordance with regulatory and Company requirements. b. All contaminated soil or other contaminated material, including spill cleanup debris, is cleaned up, containerized, and managed as a hazardous waste. Removal of the material is performed under the direction of the Emergency Coordinator or his/her qualified designee. C. If a release to the environment has occurred, the Emergency Coordinator with assistance from Ransom Environmental or the Division Environmental Engineer, determines whether or not soil or water samples must be taken and analyzed. 8 - 4 A IN 0 Contingency and Emergency Response.Plan Emergency Response Procedures December 1992 d. The release site remains off limits to unnecessary personnel until cleanup operations are complete. e. If the hazardous wastes generated during the cleanup are transported off-site by a licensed Company -approved hazardous waste transporter and delivered to a licensed Company -approved hazardous waste disposal facility, the Emergency Coordinator ensures the accuracy and completeness of the hazardous waste manifest, signs it, and ensures its proper distribution and filing. Handling of the signed manifest is discussed in Section 11. 8.2.4 Post Site Remediation When the site has been cleaned up, and the emergency response equipment has been decontaminated and returned to its proper storage location, the Emergency Coordinator: a. Notifies the proper officials that the emergency condition no longer exists and that normal operations have resumed. b. Critiques the emergency response action, including response and follow-up, along with facility management, and the Division Environmental Engineer. Included in this critique are: * the identification of the cause(s) of the emergency to prevent its recurrence. * the change of response actions to be taken in the future, if necessary; * the update of the Plan by the Division Environmental Engineer to reflect these changes made. 8.2.5 Post Site Remediation Written Notification a. If hazardous material was released during the emergency, a Hazardous Substances and PCB Release Report Form (see Figure 2), or its equivalent, is completed for the incident and distributed within the Company to: 8 - 5 Contingency and Emergency Response Plan Emergency Response Procedures December 1992 * Westboro Environmental Affairs, * the Corporate Safety Department, * the Division Environmental Engineer, and * the Westboro T&D Maintenance Procedure Coordinator. b. For releases to the environment over the RQ, a written report, consisting of a Hazardous Substances and PCB Release Report Form with a cover letter, is submitted to the DEP and the LEPC within seven days of the incident. C. If site remediation is not complete within three months of the incident, an interim report is submitted to the DEP and the LEPC. Refer to Table 3 for agency addresses. The following information is included in the release report: i. Name address and telephone number of the facility and owner and operator; ii. Date, time and type of the incident; iii. Name(s) and quantity(ies) of the material(s) involved; iv. The extent of injuries, if any; V. An assessment of actual or potential hazards to human health or the environment; vi. A description of actions taken and the estimated quantity and disposition of recovered material that resulted from the incident; vii. Copies of any laboratory analysis for material released and soil or water samples of impacted environment; viii. Proposed methods for prevention of future emergencies. The Division Environmental Engineer is available to assist the Emergency Coordinator in developing the interim report. 0 Contingency and Emergency Response Plan Emergency Response Procedures December 1992 d. When the final report is available, it is submitted to the DEP and the LEPC and distributed within the Company to: * the Division Environmental Engineer, * the Corporate Safety Department, * Westboro Environmental Affairs, and * the T&D PCB Maintenance Procedure Coordinator. 8.3 Fire and/or Explosion Actions taken in the -event of a fire and/or explosion threat are delineated in the Emergency Action Plan provided herein as Appendix F. 8.4 Flood Response In the event or threat of a flood, the Emergency Coordinator makes provisions to secure the area, if water may rise high enough to affect utilities, equipment or materials. 8.5 Spill Procedures In the case of spills, attempts to mitigate the spill are made, if possible to do so safely. Initial response actions are performed when they do not unduly endanger the employee. If possible, released material is recovered and placed in a proper container for disposal as hazardous waste. The following items are utilized to contain the spread of the release: * polyethylene sheets; * speedi-dry or similar absorbent material, * absorbent pads; and/or * rags. The locations of the containment materials are posted by the telephones nearest to the hazardous waste accumulation areas throughout the facility. Containment materials can be found in the following areas: * the second truck bay in the Upper Parking Lot, * the Transformer Room, * the Stores Department, and 8 - 7 Contingency and Emergency Response Plan Emergency Response Procedures December 1992 * the Vehicle Maintenance Garage. Methods that may be utilized to control a spill source are presented below. The specific methods used depend on the type of material spilled and the extent of the spill. Refer to Appendix C. In the event that a drum becomes damaged, the material is transferred to another drum as soon as practical or packed in an overpack. Spilled material is cleaned up with absorbent and containerized for disposal as hazardous waste. 8.6 Bomb Threat Response Actions taken in the case of a bomb threat are delineated in the Emergency Action Plan, provided herein as Appendix F. 8.7 Securing the Site Once the emergency has passed, the Emergency Coordinator directs the appropriate cleanup actions. In case of spills, the spilled material, cleanup debris and contaminated soil, if any, is containerized and the contaminated surfaces are cleaned. If the released material contains PCBs, the contaminated surfaces are double rinsed using Superwash: Based on the assessment of the type(s) of material released, the Emergency Coordinator structures and supervises the response proceedings to ensure that the wastes are properly collected, segregated, containerized, labelled, stored, and disposed of. The Emergency Coordinator is responsible for the proper management, including disposal, of hazardous waste in accordance with federal, state, local, and Company policies, procedures, regulations and guidances. The NEES Companies' Hazardous Waste, Substances and PCB Procedures Manual is the Company document which delineates proper hazardous waste handling procedures. The Emergency Coordinator remains at the site until the cleanup operation has been completed and ensures that the site is secure and that operations may resume/continue as usual. The Emergency Coordinator also ensures that all of the cleanup wastes and debris are placed in compatible containers and that each container is properly labeled and disposed of. 8.8 Decontamination All equipment used in an emergency response operation (shovels, hoses, protective clothing, etc.) is thoroughly decontaminated using Superwash or properly disposed of as hazardous waste. Before resuming his/her normal duties, the Emergency Coordinator makes arrangements for the replacement or refill of all fire extinguishers, absorbent containers, and/or other equipment that was depleted during the 8 - 8 Contingency and Emergency Response Plan Emergency Response Procedures December 1992 emergency response. All emergency response equipment including fire protection equipment, spill control equipment and communications equipment are maintained and tested periodically, as warranted, and immediately after use. 8.9 Critique of Response and Follow-up When emergency response actions are complete, including the submission of all required reports, the Emergency Coordinator meets with the Division Environmental Engineer and the District Superintendent to evaluate all response actions. other pertinent personnel may participate in the evaluation as needed. If certain response actions are determined to be ineffective, then alternative actions are developed, this Plan is amended accordingly, and the new information is communicated to the impacted personnel and agencies. 8 - 9 Contingency and Emergency Response Plan December 1992 9.0 Evacuation Evacuation of the facility may be necessary in the event of a fire, bomb threat or release of hazardous material. A facility evacuation is signaled by a series of 15 -second blasts of the building siren system. When the facility alarm is sounded, personnel evacuate the building and follow the instructions of the District Manager, Emergency Coordinator and/or evacuation monitors. The routes of evacuation are clearly marked within the facility by "EXIT" or "EVACUATION" signs. In addition, building floor plans indicating evacuation routes are posted throughout the facility. No employee reenters the facility until the Emergency Coordinator has determined that the building is safe for re-entry. The evacuation -procedure- is included in, the Emergency Action Plan provided herein as Appendix F. 9 - 1 Contingency and Emergency Response Plan December 1992 10.0 Emergency Medical Treatment and First Aid The Merrimack Valley District Headquarters facility has limited facilities to supply emergency medical treatment. However, Lawrence General Hospital is located within ten (10) miles of the facility and is contacted immediately in the event of a medical emergency. The North Andover Fire Department, located within five (5) miles of the facility, may also be contacted to provide assistance with medical emergencies. Both agencies are familiar with the location and operations of the facility. In the event that an employee is exposed to a hazardous substance resulting in any injury or exhibits signs or symptoms associated with chemical overexposure, MEC is prepared to supply as much information as possible to the treating physician regarding the incident. This information may include: * the identity of the hazardous chemical(s) to which the employee may have been exposed; * a description of the conditions under which the exposure occurred, and; * a description of signs and symptoms of exposure that the employee is exhibiting; and * the Material Safety Data Sheet(s) for the substance(s). Massachusetts Electric Company employees receive information regarding first aid and signs and symptoms associated with chemical overexposure during their annual Hazard Communication Standard and Hazardous Waste/PCB training sessions. All employees who handle hazardous materials/waste receive CPR and first aid training in the form of at least eight hours of initial training and four hours of annual review. 10 - 1 Contingency and Emergency Response Plan December 1992 11.0 Recordkeeping There are several records which are maintained at the facility, including: * emergency release reports, * hazardous waste manifests, * annual/biennial hazardous waste reports, * exception reports, * land disposal restriction notices, and * inspection forms. In addition, medical records associated with employee overexposures to hazardous materials/waste are also maintained by the Company. Refer to Appendix D for more detailed information regarding recordkeeping. 11.1 Emergency Release Reports As discussed in Section 8.0 above, a written emergency release report may be required in the event of a release of hazardous material over the reportable quantity. These reports are maintained in the T&D District Superintendent's Office and remain on file for at least seven years. 11.2 Manifests The manifest contains eight copies. The disposition of the copies is as follows: Copy 1. Disposal Facility mails to Destination State Copy 2. Disposal Facility mails to Generator State Copy 3. Disposal Facility mails to Generator Copy 4. Disposal Facility retains Copy 5. Transporter retains Copy 6. Generator mails to Destination State Copy 7. Generator mails to Generator State Copy 8. Generator retains Copies 3 and 8 of all manifests are kept on file in the Stores Department, the Transportation Department, or the T&D District Superintendent's Office, depending on jurisdiction, Contingency and Emergency Response Plan Recordkeeping December 1992 for at least seven years from the date of the shipment. Manifests associated with spill response activities are filed in the T&D District Superintendent's Office. 11.3 Exception Reports If the Merrimack Valley District Headquarters does not receive Copy 3 of the manifest from the disposal facility within 35 days, MEC contacts the facility to determine the disposition of the waste. If the copy is not received within 45 days, an exception report is filed with the Department of Environmental Protection (DEP), and the Regional Administrator of the U.S. Environmental Protection Agency (EPA). The exception report includes the following: a. A legible copy of the initial manifest given to the transporter. b. A cover letter signed by facility management or the Division Environmental Engineer explaining efforts taken to locate the hazardous waste and the results of those efforts. 11.4 Land Disposal Restriction Notifications A completed Land Disposal Restriction (LDR) Notification form accompanies all shipments of hazardous waste containing substances which are banned from disposal in or on land. These substances include all listed and characteristic wastes, "California List" wastes and other wastes. As the generator, MEC has instructed the TSDF as to which treatment technology for disposal to apply. The original copy of the LDR accompanies the shipment and a copy remains on file at the Merrimack Valley District Headquarters for at least seven years. 11.5 Accident Reports The Company maintains employee accident reports, including reports of injuries resulting from overexposure to a hazardous substance. Whenever an event takes place such as a spill, leak or other occurrence resulting in the likelihood of exposure to a hazardous substance, the employee is provided the opportunity to receive medical attention. If an employee develops signs or symptoms associated with a hazardous chemical overexposure, medical attention is also provided. The records of these medical examinations or consultation s are kept by the Company for at least 30 years after the employee has left the NEES Companies. Copies of the accident reports are maintained at the District Office while the person is employed with MEC. Upon their leaving the Company, these files are forwarded to NEES Companies' Medical Department for permanent retention. 11 - 2 TABLES TABLE 1 EMERGENCY COORDINATORS Primary: Richard Harding North Andover ext 1472 9 Sycamore Avenue home: , (603) 898-5588 Salem, NH pager: (617) 841-1255 carphone:! (508) 989-2476 Alternates: H. Donald Burgess North :Andover ext 1350 3 Bowlen Avenue home: (508) 465-9211 Newburyport, MA pager: (617) 669-8717 i or 669-8718 carphone: (508) 989-2333 R. L. Rosentrater North Andover ext 1350 52 Hampstead Street home: (508) 683-9598 Methuen, MA pager: (617) 669-8717 or 669-8718 carphone: (508) 989-2320 TABLE 2 SPILL CLEANUP EQUIPMENT Stores Code Kit Box No Stores Code 591200 483065 462735 472433 472434 472326 472324 Spill Cleanup Equipment Item Standard Barrel (DOT -approved) "Speedi-dry" Absorbent (50 pounds) Shovel (flat) Broom Goggles Eye Shields Gloves Light Duty Nitrile Gloves Heavy Duty Granflex Protective Clothina 466861 Coveralls, Disposable - Kit Use 462358 Booties, Disposable 466130 Plastic Drop Cloth, 9 x 12 467242 PCB Labels 478045 Plastic Pail - 10 qt 591015 Waterless Hand Cleaner 466125 Rags 486488 2" Duct Tape 476800 Metal Marker - Yellow 460575 Plastic Bags - 55 gal '- Barrel Hooks 478400 3M Absorbent Pillows 482700 3M Absorbent Pads '- Solvent* 599777 Super Wash* (5 gal) Cover Liner * Obtain only when needed. (*) items not to be stored in kit. 0 0 TABLE 3 AGENCY TELEPHONE NUMBERS AND ADDRESSES EMERGENCY RESPONSE Cleanup Contractor Clean Harbors 1200 Crown Colony Drive P.O. Box 9137 Quincy, Massachusetts 02269 Contact person: Bill King (800) OIL -TANK Environmental Consultant FEDERAL STATE Ransom Environmental Consultants Brown's Wharf Newburyport, Massachusetts 01950 Contact person: Timothy Snay (508) 465-1822 U.S. Environmental Protection Agency (EPA) U.S. Environmental Protection Agency (617) 565-3279 National Coast Guard National Response Center (NRC) National Response Center (800) 424-8802 Massachusetts Department of Environmental Protection Northeast Region 10 Commerce Way Woburn, Massachusetts 01801 (617) 935-2162 During non -business hours, contact State Police (800) 525-5555 LOCAL AGENCY TELEPHONE NUMBERS AND ADDRESSES (Continued) North Andover Board of Health 120 Main Street North Andover, Massachusetts 01845 Contact person: Mr. Gayton Osgood, Director (508) 682-6483 North Andover Fire Department 124 Main Street North Andover, Massachusetts 01845 Contact person: Mr. William Dolan, Fire Chief (508) 686-3812 (non -emergency) 689-7777 (emergency) North Andover Police Department 566 Main Street North Andover, Massachusetts 01845 Contact person: Mr. Richard Stanley, Police Chief (508) 683-3168 (non -emergency) 686-1212 (emergency) Local Emergency Planning Committee (LEPC) c/o the North Andover Fire Department 124 Main Street North Andover, Massachusetts 01845 Contact person: Mr. William Dolan, Fire Chief (508) 686-3812 (non -emergency) 689-7777 (emergency) Local Hospital Northeast Central Medical Emergency Direction (NE CMED) Lawrence General Hospital 1 General Street Lawrence, Massachusetts 01841 Contact person: Peter Cole, Director Chris Robert, Supervisor (508) 683-4000 (non -emergency) 685-0224 (emergency) ^ FIGURES a Cb T m O CO co c CO N U 't C Oy 00 a T m c m U CD N C .D c o o ao m U mm N 0 Z 0 U m a � E c Z i= Q ❑ ui T I� Q m m m m m � m cc o O m c °C m (mll T O 1° 3 0 0 o.Va w m � E c wU H a p ami U E m ro 0 U io cc I m 2.0 m Y it L U 0CD 3 m om Ucc cmm �a CO LL m ao m m m U)oo0c� m Z o CL m E ~U E U O00 U- N in >0 in (Y t6 Z ❑❑❑❑ E m O V m 0 CL � IY o 0 J UvU m m w 0 m U u�� a E c m r 1111 o 12 1=aZ� N ao T 0a Oco wI CL a n. a V s s 8 lL w A o c U cm c U O c CL U ^m E > w c 5 m Z a cc U m Z m d v O CL b m c a) 0 U Z C ao .. - O a c' m m c Z E 0 w r 2 Q U 'o O m m *p m m cc in F 3p ❑ ❑ ❑ I� Q m m m m m � m cc o O m c °C m (mll T O 1° 3 0 0 o.Va w m � E c wU H a p ami U E m ro 0 U io cc I m 2.0 m Y it L U 0CD 3 m om Ucc cmm �a CO LL m U m E CD p Z m Zami m D 3 �°, 0 0 U c � m aE 3 0 m c U w Al Figure 2 cc . ap of C -: N Qh T T T T .. . m m v C 0 N m CL O U c m m E U c a 0 0 m m c U C16 � m O O a° 0 � 0 0 m 0 �► O a6 CO o a O as m c v = m N m O ` O O o m O m m E ° a ¢ ° oU m v a cc c 3 m C m m N aE = '9t Tc�33tn 2 o o a, m a, C-�T" 0 0 3 ou)m- m 0 v ` O O coamOa: 2:_ = tom ao m m ro �wea m d g� ° d d m a mcc¢maccc cc Q ❑❑❑❑❑❑ 4 T m ao 0 � U)oo0c� m Z o CL m E 0 Z O00 U- N in >0 in (Y U) ❑ ❑❑❑❑ E m O V m 0 CL � IY o 0 J a a0 J w 0 m U u�� a cpp c m r 1111 ❑ 1=aZ� N ao T N m U m E CD p Z m Zami m D 3 �°, 0 0 U c � m aE 3 0 m c U w Al Figure 2 cc . ap of C -: N Qh T T T T .. . m m v C 0 N m CL O U c m m E U c a 0 0 m m c U C16 � m O O a° 0 � 0 0 m 0 �► O a6 CO o a O as m c v = m N m O ` O O o m O m m E ° a ¢ ° oU m v a cc c 3 m C m m N aE = '9t Tc�33tn 2 o o a, m a, C-�T" 0 0 3 ou)m- m 0 v ` O O coamOa: 2:_ = tom ao m m ro �wea m d g� ° d d m a mcc¢maccc cc Q ❑❑❑❑❑❑ 4 T m ao 0 � U)oo0c� m CL m E c m O00 c Z U) t� N O E m c o `o � IY CD m U J a a0 J ° Z a u�� a Fm- Fm- 1111 ❑ N ao.a0. N Oco wI CL a n. a V s s 8 lL w A o c U cm U O CD CL U > w C Z T m cc U m m U m d o U CLI CL b c U U Z Z a a m ❑1111❑ m U m E CD p Z m Zami m D 3 �°, 0 0 U c � m aE 3 0 m c U w Al Figure 2 cc . ap of C -: N Qh T T T T .. . m m v C 0 N m CL O U c m m E U c a 0 0 m m c U C16 � m O O a° 0 � 0 0 m 0 �► O a6 CO o a O as m c v = m N m O ` O O o m O m m E ° a ¢ ° oU m v a cc c 3 m C m m N aE = '9t Tc�33tn 2 o o a, m a, C-�T" 0 0 3 ou)m- m 0 v ` O O coamOa: 2:_ = tom ao m m ro �wea m d g� ° d d m a mcc¢maccc cc Q ❑❑❑❑❑❑ 4 T cc 0 U)oo0c� O00 U) N N O fn w m� � IY 0) �Arr T m co O _ 8100 co � < N t0 N Oco wI OJ T v0 w U cm U CL ,g > w Z T m cc (n �¢w UiCc J =o Z -� 0 o Z m �rnn-0= L r 'o o -V5 r m U a 0(.6wa°¢ m U m E CD p Z m Zami m D 3 �°, 0 0 U c � m aE 3 0 m c U w Al Figure 2 cc . ap of C -: N Qh T T T T .. . m m v C 0 N m CL O U c m m E U c a 0 0 m m c U C16 � m O O a° 0 � 0 0 m 0 �► O a6 CO o a O as m c v = m N m O ` O O o m O m m E ° a ¢ ° oU m v a cc c 3 m C m m N aE = '9t Tc�33tn 2 o o a, m a, C-�T" 0 0 3 ou)m- m 0 v ` O O coamOa: 2:_ = tom ao m m ro �wea m d g� ° d d m a mcc¢maccc cc Q ❑❑❑❑❑❑ 4 T APPENDIX A Letters of Transmittal of Contingency Plans to Emergency Response Agencies and Local Authorities Massachusetts Electric A New England Electric System company December 21, 1992 Mr. Richard Stanley Police Chief North Andover Police Department Mcssachusems Electric Company 1 10 1 Turnpike Street Ncr'h Andover, Massachusetts 0 1845-6109 Te,ephone: (508) 683-951 1 566 Main Street North Andover, Massachusetts 01845 re: Massachusetts Electric Company Contingency and Emergency Response Plan Dear Mr. Stanley: In accordance with Massachusetts hazardous waste regulation 310 CMR 30.522, enclosed is the Contingency and Emergency Response Plan (Plan) for the Massachusetts Electric Company facility located at 1101 Turnpike Street, North Andover, Massachusetts. This Plan presents procedures implemented at the facility to prevent and minimize hazards to human health or the environment from fires, explosions, or releases of hazardous waste/material or its constituents to air, soil, or surface water. If necessary, the Massachusetts Electric Company will request emergency services from the Police Department. Therefore, please review the Plan to become more familiar with our facility and our emergency procedures and retain it for future reference. If the Plan is changed or amended, the revisions will be transmitted to you. If your department is not able to assist this facility during an emergency or if you have any questions regarding this Plan, please contact Sabrina L. Lewis, Environmental Engineer at (508) 683-9511, extension 1379. Thank you for your assistance. Sincerely, Dennis E. Snay Vice President & District Manager cc: J. H. Dickson J. M. Kwasnik D. J. Mahoney R. A. Yanco No Enclosures Massachusetts Electric A New England Electric System company December 21, 1992 Massachusetts Electric Company 1 101 Turnpike Street North Andover, Massachusetts 01845-6109 Telephone: (508) 683-951 1 Mr. Peter Cole Northeast Central Medical Emergency Direction (NE CMED) Lawrence General Hospital 1 General Street Lawrence, Massachusetts 01845 re: Massachusetts Electric Company Contingency and Emergency Response Plan Dear Mr. Cole: In accordance with Massachusetts hazardous waste regulation 310 CMR 30.522, enclosed is the Contingency and Emergency Response Plan (Plan) for the Massachusetts Electric Company facility located at 1101 Turnpike Street, North Andover, Massachusetts. This Plan presents procedures implemented at the facility to prevent and minimize hazards to human health or the environment from fires, explosions, or releases of hazardous waste/material or its constituents to air, soil, or surface water. If necessary, the Massachusetts Electric Company will request emergency medical services from hospital. Therefore, please review the Plan to become more familiar with our facility and our emergency procedures and retain it for future reference. If the Plan is changed or amended, the revisions will be transmitted to you. If the hospital is not able to assist this facility during emergency or if you have any questions regarding this Plan, please contact Sabrina L. Lewis, Environmental Engineer. at 683-9511, extension 1379. Thank you for your assistance. Sincerely, Dennis E. Snay- Vice President & District Manager cc: J. H. Dickson J. M. Kwasnik D. J. Mahoney R. A. Yanco No Enclosures an (508) Massachusetts Electric A New England Electric System company December 21, 1992 Mr. Steven Ransom Ransom Environmental Consultants Brown's Wharf Newburyport, Massachusetts 01950 ,Massachusetts Electric Company 1 101 Turnpike Street North Andover, Massachusetts 0 1 845-61 09 Telephone: (508) 683-951 1 re: Massachusetts Electric Company Contingency and Emergency Response Plan Dear Mr. Ransom: In accordance with Massachusetts hazardous waste regulation 310 CMR 30.522, enclosed is the Contingency and Emergency Response Plan (Plan) for the Massachusetts Electric Company facility located at 1101 Turnpike Street, North Andover, Massachusetts. This Plan presents procedures implemented at the facility to prevent and minimize hazards to human health or the environment from fires, explosions, or releases of hazardous waste/material or its constituents to air, soil, or surface water. If necessary, the Massachusetts Electric Company will request emergency services from your company. Therefore, please review the Plan to become more familiar with our facility and our emergency procedures and retain it for future reference. If the Plan is changed or amended, the revisions will be transmitted to you. If your company is not able to assist this facility during an emergency or if you have any questions regarding this Plan, please contact Sabrina L. Lewis, Environmental Engineer at (508) 683-9511, extension 1379. Thank you for your assistance. Sincerely, Y� Dennis E. Snay I- Vice President & District Manager cc: J. H. Dickson J. M. Kwasnik D. J. Mahoney R. A. Yanco No Enclosures Massachusetts Electric A New England Electric System company December 21, 1992 Mr. Bryan Diehl Clean Harbors 1200 Crown Colony Drive P. O. Box 9137 Quincy, Massachusetts 02269 Massachusetts Electric Company 1 101 Turnpike Street North Andover, Massachusetts 01845-6109 Telephone: 1508) 683951 1 re: Massachusetts Electric Company Contingency and Emergency Response Plan Dear Mr. Diehl: In accordance with Massachusetts hazardous waste regulation 310 CMR 30.522, enclosed is the Contingency and Emergency Response Plan (Plan) for the Massachusetts Electric Company facility located at 1101 Turnpike Street, North Andover, Massachusetts. This Plan presents procedures implemented at the facility to prevent and minimize hazards to human health or the environment from fires, explosions, or releases of hazardous waste/material or its constituents to air, soil, or surface water. If necessary, the Massachusetts Electric Company will request emergency services from your company. Therefore, please review the Plan to become more familiar with our facility and our emergency procedures and retain it for future reference. If the Plan is changed or amended, the revisions will be transmitted to you. If your company is not able to assist this facility during emergency or if you have any questions regarding this Plan, please contact Sabrina L. Lewis, Environmental Engineer at 683-9511, extension 1379. Thank you for your assistance. Si ely, 'L( Dennis E. Snay Vice President & District Manager cc: J. H. Dickson J. M. Kwasnik D. J. Mahoney R. A. Yanco No Enclosures an (508) Massachusetts Electric A New England Electric System company December 21, 1992 Massachusetts Department of Environmental Protection Northeast Region 10 Commerce Way Woburn, Massachusetts 01801 Mossochusetts Electric Company 1 101 Turnpike Street North Andover, MCS50Chusens 01 8456109 Telephone: (508) 683-9511 re: Massachusetts Electric Company Contingency and Emergency Response Plan Dear Sir or Madam: In accordance with Massachusetts hazardous waste regulation 310 CMR 30.522, enclosed is the Contingency and Emergency Response Plan (Plan) for the Massachusetts Electric Company facility located at 1101 Turnpike Street, North Andover, Massachusetts. This Plan presents procedures implemented at the facility to prevent and minimize hazards to human health or the environment from fires, explosions, or releases of hazardous waste/material or its constituents to air, soil, or surface water. If the Plan is changed or amended, the revisions will be transmitted to you. If you have any questions regarding this Plan, please contact Sabrina L. Lewis, Environmental Engineer at (508) 683-9511, extension 1379. Sincerely, Dennis E. Snay Vice President & District Manager cc: J. H. Dickson J. M. Kwasnik D. J. Mahoney R. A. Yanco No Enclosures Massachusetts Electric A New England Electric System company December 21, 1992 Mr. Gayton Osgood Director North Andover Board of Health 120 Main Street North Andover, Massachusetts 01845 Mossochusens Electric Company 1 101 Turnpike Street North Andover, Massachusetts 01845-6109 Te'lephone: 1508) 6839511 re: Massachusetts Electric Company Contingency and Emergency Response Plan Dear Mr. Stanley: In accordance with Massachusetts hazardous waste regulation 310 CMR 30.522, enclosed is the Contingency and Emergency Response Plan (Plan) for the Massachusetts Electric Company facility located at 1101 Turnpike Street, North Andover, Massachusetts. This Plan presents procedures implemented at the facility to prevent and minimize hazards to human health or the environment from fires, explosions, or releases of hazardous waste/material or its constituents to air, soil, or surface water. Please review the Plan to become more familiar with our facility and our emergency procedures and retain it for future reference. If the Plan is changed or amended, the revisions will be transmitted to you. If you have any questions regarding this Plan, please contact Sabrina L. Lewis, Environmental Engineer at (508) 683-9511, extension 1379. Sincerely, 0---� Dennis E. Snay Vice President & District Manager cc: J. H. Dickson J. M. Kwasnik D. J. Mahoney R. A. Yanco No Enclosures Massachusetts Electric A New England Electric System company December 21, 1992 Local Emergency Planning Committee (LEPC) c/o Mr. William Dolan, Fire Chief North Andover Fire Department 124 Main Street North Andover, Massachusetts 01845 Massachusetts Electric Company 1 101 Turnpike S+reet North Andover, Massachusetts 0 1845,6109 Telephone: (508) 683-9511 re: Massachusetts Electric Company Contingency and Emergency Response Plan Dear Mr. Dolan: In accordance with Massachusetts hazardous waste regulation 310 CMR 30.522, enclosed is the Contingency and Emergency Response Plan (Plan) for the Massachusetts Electric Company facility located at 1101 Turnpike Street, North Andover, Massachusetts. This Plan presents procedures implemented at the facility to prevent and minimize hazards to human health or the environment from fires, explosions, or releases of hazardous waste/material or its constituents to air, soil, or surface water. Please review the Plan to become more familiar with our facility and our emergency procedures and retain it for future reference. If the Plan is changed or amended, the revisions will be transmitted to you. If you have any questions regarding this Plan, please contact Sabrina L. Lewis, Environmental Engineer at (508) 683-9511, extension 1379. Sincerely, r Dennis E. Snay Vice President & District Manager cc: J. H. Dickson J. M. Kwasnik D. J. Mahoney R. A. Yanco No Enclosures Massachusetts Electric A New England Electric System company December 21, 1992 Board of Selectmen Town of North Andover 120 Main Street Massachusetts Electric Company 1101 Turnpike Street North Andover, Massachusetts 0 1 845-61 09 Telephone: 1508) 683951 1 North Andover, Massachusetts 01845 re: Massachusetts Electric Company Contingency and Emergency Response Plan Dear Mr. Stanley: In accordance with Massachusetts hazardous waste regulation 310 CMR 30.522, enclosed is the Contingency and Emergency Response Plan (Plan) for the Massachusetts Electric Company facility located at 1101 Turnpike Street, North Andover, Massachusetts. This Plan presents procedures implemented at the facility to prevent and minimize hazards to human health or the environment from fires, explosions, or releases of hazardous waste/material or its constituents to air, soil, or surface water. Please review the Plan to become more familiar with our facility and our emergency procedures and retain it for future reference. If the Plan is changed or amended, the revisions will be transmitted to you. If you have any questions regarding this Plan, please contact Sabrina L. Lewis, Environmental Engineer at (508) 683-9511, extension 1379. Sincerely, &�t<- Dennis E. Snay ! — Vice President & District Manager cc: J. H. Dickson J. M. Kwasnik D. J. Mahoney R. A. Yanco No Enclosures APPENDIX. B Description of Vendor Capabilities and Letter of Commitment Ele a in H a rpb ffio ENVIRONMENTAL SERVICES COMPANIES BOSTON FIELD SERVICE OFFICE 530 E. FIRST STREET, SOUTH BOSTON, MA 02127 24 HOUR SERVICE (617) 269-5830 1-800-OIL-TANK May 11, 1992 Massachusetts Electric Merrimack Valley District HQ 1101 Turnpike Street North Andover, MA 01845 Attn: Sabrina L. Lewis Dear Ms. Lewis, Clean Harbors is the largest provider of comprehensive environmental services in New England. Our hazardous waste management services -include treatment, storage, resource recovery, transportation and disposal of hazardous materials. Our environmental remediation services include surface remediation, groundwater restoration, underground storage tank management and site decontamination. We also provide analytical services which complement our customers' complex environmental requirements. These services are available on a 24 hour emergency basis. Clean Harbors of Kingston, Inc. staffs emergency response offices throughout New England. The closest office to your facility is our South Boston office. We have approximately 50 supervisors and approximately 250 other employees who are experienced in emergency response. To complement the South Boston office, our Remedial Services Division for heavy equipment, analytical services for analysis, and our Braintree facility for disposal are also on call 24 hours a day. This enables us to better service our customers in a time and cost efficient manner. We operate two separate spill teams everyday. The teams consist of supervisors, foreman, operators (heavy equipment, vacuum trucks, etc.), field technicians, chemist, engineers, and health and safety personnel. Our record in emergency response speaks for itself. We currently serve as an on call contractor for the Massachusetts Department of Environmental Protection for chemical spills and oil spills on a rotating basis. We perform over 1800 spill responses per year. All personnel undergo strict training. In addition to a weekly one hour safety training, all employees undergo a 40 hour OSHA approved training. MASSACHUSETTS RHODE ISLAND CONNECTICUT NEW YORK NEW JERSEY MAINE NEW HAMPSHIRE MARYLAND ILLINOIS OHIO Page 2 If you have any questions or would like to discuss our services in person, please feel free to contact me at (617) 269-5830. sincerely, Harry E. Davidson Vice President/General Manager HED/lb EleainHarbo PM ENVIRONMENTAL SERVICES COMPANIES BOSTON FIELD SERVICE OFFICE 530 E. FIRST STREET, SOUTH BOSTON, MA 02127 24 HOUR SERVICE (617) 269-5830 1 -800 -OIL -TANK May 11, 1992 Massachusetts Electric Merrimack Valley District HQ 1101 Turnpike Street North Andover, MA 01845 Attn: Sabrina L. Lewis Dear Ms. Lewis, This letter is to inform you that Clean Harbors will provide emergency response services at the request of and under the direction of an authorized representative, on a time and material basis in accordance with our prevailing rates. For emergency service, please call (617) 269-5830 or 1 -800 -OIL -TANK. If you have any questions concerning our emergency response capabilities, please feel free to contact me at (617) 269-5830. Sincerely, Harry E Davidson Vice President/General Manager HED/lb MASSACHUSETTS RHODE ISLAND CONNECTICUT NEW YORK NEW JERSEY MAINE NEW HAMPSHIRE MARYLAND ILLINOIS OHIO APPENDIX C Hazardous Material Cleanup Standards HAZARDOUS MATERIAL CLEANUP STANDARDS The procedures below present basic spill treatment methods for hazardous materials commonly used by Massachusetts Electric. Mitigation of large spills may warrant acquiring assistance from outside cleanup contractor(s). Only Company employees who have received hazardous waste management and emergency response training may undertake cleanup actions beyond simple containment activities. OILS (eg., Fuel oil, gasoline, transformer oil, hydraulic fluids) 1. Safety Precautions Avoid contact with skin and eyes. Wear eye protection and gloves and in the case of large releases, wear a protective suit in addition to the eye protection and the gloves. Shut off all ignition sources. 2. Containment Dike the spill area with absorbent booms, polyethylene sheets or other appropriate materials. Cover drains within the spill area. Contain small spills with speedi-dry or other absorbent materials. 3. Cleanup Remove free liquids for disposal or recycling, if practical and appropriate. Absorb the remaining material with a noncombustible absorbent such as speedi-dry and shovel the material into drums using spark -proof equipment. Remove and containerize contaminated soil and other impacted material until visible traces of oil are gone. Final cleanup is confirmed by sampling and analysis. 4. Current Cleanup Standards Current standards require the attainment of Total Petroleum Hydrocarbon (TPH) concentrations in soil of less than 300 parts per million (ppm) in non -sensitive environments such as urban and industrial areas and 100 ppm in sensitive environments such as sole source aquifer recharge areas, residential lawns, playgrounds, grazing lands, etc. 5. Post -Cleanup and Disposal Decontaminate all non -disposable cleanup and personal protective equipment using Superwash. Dispose of personal protective equipment that cannot be decontaminated along with the cleanup debris as hazardous waste OILY DEBRIS, in accordance with NEES Companies' hazardous waste disposal procedures. SOLVENTS (eg., mineral spirits, paint thinners, 1,1,1 - trichloroethane) 1. Safety Precautions Avoid contact with skin and eyes and avoid breathing vapors. Wear goggles and gloves for small spills. For larger spills, also wear a protective suit in addition to the goggles and gloves. Use a self-contained breathing apparatus (SCBA) for large spills in confined areas. Shut off all ignition sources. A light water spray may be used to keep down vapors while mitigating a large spill. 2. Containment Dike large spills with absorbent booms and/or polyethylene sheets. Cover drains in the spill area. Cleanup small spills with noncombustible absorbent material(s). 3. Cleanup Cleanup spills with sand or other noncombustible absorbent material. Use spark -proof equipment to shovel debris into DOT -approved drums. 4. Post -Cleanup and Disposal Decontaminate all non -disposable cleanup and personal protective equipment using Superwash. Dispose of personal protective equipment that cannot be decontaminated along with the cleanup debris as a land ban restricted hazardous waste, in accordance with NEES Companies' hazardous waste disposal procedures. The waste description will vary with the released material. APPENDIX D Environmental Files Q Z LL U. Z LU N N 0 a (h o o ui o al ami o m a o cl � c o O N ` co 0 5. e N sC O C o >+ CL 0 N « i cti 3 0 a� co Co E O _— O V20 N N ttS o C co w C C «O M U o v0- 00 = a N O = N z _ o N cu ` co O m C N O C 0 U ca t C U p L C CU 0 CU0 U m ai ca U) y a) 'a0� n. 0 OL 0 a)cd OL 'a 21 E (n a o O = c0 .C. > > C 0 M L O 0) (D E N c 0 _ N co c c o E C 0 cca � "- c LL >, N w cd co c a� vi 0 E v m ca �. C v 0 c o o m a 0vOi N a E E E E E E O O O Q O O O O O "O. ` O p oU CJ � o 0 mm >.aaa c ) a CL o m co I N m V O m10 O 0) O C_ c c cu .� CL N O �m E > > N c 3 a N C C _c C O. Oo c c O N C I Vi i% u-� n0F`-I`- f=Y c c co a i c c 4c c Z O O 0 C C w �, «. � W >. �, �, c$ = �, F rU O m c0 «< 0 �' GI �' O O � O O. O. � � i � i ►N• � N C N N C 0 cr >\ >+ >% >� co C N C c N c 0 0 p m O N O Cl. C C C O p Q O ►- ►.CL W �a ((f E►. � M E CO E^ Cc N N a) 4) T E E En^ M (d CO N(D EEE � >. 0 t4 O O co 0 U. �E a>,E MMMM ^ E^ 000 0o n ��n E a as a r w. aaa w M(oM WCO .. o .. w a a: a N ►N. N J M ctt cCi z O O 0 Q Q c Q 0 m w cu co cif m mm m c� cts c� 0 W W w 0 0 0 0 0 0 0 0 0 0 .. .. 0 c 0 0 .-. «. 0 m m m m co 0 0 0 0 L OU J J J J J J J J J J J �' �' J J y 0 0 0 c c J J J �-' •- N N 0 0 0 0 0 o o o o o•C c J J J J J J J J J J Z ¢J _y U0 cc F- (u O LU O cti cE C a O aL yo z 0 co cc a w 0 N E E � p aai v con C o Y Z C7 O oCL E U_ o O 1 Z O in o o v m a C 3 la- O ca ¢ c >. W Z z ¢ y a y O w O— p w -J ¢ c0 0 c a a >� N N p p 0 0 o a N Z w p U- O � _ Z a) 0 C Q a O 0 C E U O w w N rO c- m 0 C '0 0 L) ¢ C C W O O 0 0 U a cts m ® Q N O F- y U N U) N 4 c 0 C Z `p«C. Z C N N y (/� a¢ y E m m= N 0 0 _y d 'C V a a N 0 rn E U p ctf Oc c O y :. O 0 a Eo �3 w N N 0 t N .. t O z o� map O p (tS m �a�T�mF 0 Y C V a` o CD N¢ N p J U F- > a N J o LL Z _ 0¢ O 0 C C J > co a d y U1 p ff N(3 0 c >. 0 3 ¢ y cco p L. M (¢ y C C O p p J C O 3> O Q C C o¢ O O c>> N N Z' p a O 0 0 0 C¢ }- C) a Y 0 0 «. c 0¢ ¢ 0 C c c Z O a c� U) c. m o F- � c rn O m rn p p o (n z rn o o U 0 C N 'ns .0 O U¢ (7 a 3 p E >, >. >% cti I W o a 0 C V w C¢ e (:. C C a� cd O >+ O C N N �c C C C O ? CO _¢ ` @ O F- F- C O w O _ ¢ O m C a m t t U ctt p w w cts v U U= W M 0 0 M c o .0 o m m m c C C=` F- .3e y a C]�ZF - = aUz=JJ (No cNa ccc FO- E t F-F-F-� U a U U U a aaa a(4 Z 0 0 o a a o o a s F. �mz0¢ 3 m(�UoU)w ENVIRONMENTAL FILES The files listed below are to be maintained and available for inspection at each facility that: • generates hazardous waste; • has asbestos and/or personnel trained to remove asbestos; • maintains water management permits; and/or • utilizes underground storage tanks. ASBESTOS Asbestos Removal Reports Maintain a file of completed Asbestos Removal Reports for at least 30 years. Traininq Records Maintain a complete list of asbestos workers along with a copy of their training course certificates and any applicable state licenses. HAZARDOUS WASTE Manifest Files File by year in chronological order, most recent on top. The generator copy (copy 8), the facility return copy (3), and any associated land ban notifications must be stapled together with copy 3 on top. If the originals are not available, you must at least have a photocopy. You have 45 days to receive the facility returned copy (copy 3) indicating proper disposal. After that period of time, you must track down the copies via written correspondence. If you have not received the copy 3 manifest within 30 days, contact the Division Environmental Engineer. Manifests must be retained for at least 7 years and land ban restriction notices must be retained with the associated manifest for at least 7 years. Distribution of the manifest copies is presented below: Copy 1: Copy 2: Copy 3: Copy 4: Copy 5: Copy 6: Copy 7: Copy 8: Disposal Facility mails to Destination State Disposal Facility mails to Generator State Disposal Facility mails to Generator Disposal Facility retains Transporter retains Generator mails to Destination State Generator mails to Generator State Generator retains Land Disposal Restriction (LDR) Notification Forms An accompanies each shipment of waste containing substances which banned from disposal in or on land. These substances include listed and characteristic wastes, "California List" wastes other wastes. Using this form, the generator instructs disposal facility as to the treatment technology for disposal each waste stream. The original copy of the LDR accompanies LDR are all and the for the shipment and a copy remains on file attached to the associated manifest for at least 7 years. Exception Reports If the generator does not receive copy 3 of the manifest from the disposal facility within 30 days, the generator must contact the Division Environmental Engineer so that inquiry into the whereabouts of the document can be made. If the copy 3 is not received within 45 days, an exception report must be filed with the Department of Environmental Protection (DEP) and the Regional Administrator of the U.S. Environmental Protection Agency (EPA). The exception report must include the following: • a legible copy of the initial manifest given to the transporter; and • a cover letter signed by facility management or the Division Environmental Engineer explaining efforts taken to locate the hazardous waste and the results of those efforts. Exception reports for manifest deficiencies must be maintained for at least 7 years. Waste Analysis Keep any waste profile sheets, laboratory analyses or other waste determinations for at least 7 years from the date the hazardous waste was last sent from the facility. Annual/Biennial Reports Retain reports for at least 7 years from the due date of the report. Request copies of these reports from the Environmental Affairs Department if the reports are not currently available at your facility. Annual PCB Reports Retain the annual PCB reports that are issued from the Environmental Affairs Department permanently. Completed Inspection Forms All records of inspections relating to hazardous waste management must be retained for at least 7 years. Spill Reports Maintain release/spill reports and any associated correspondence with state or local agencies concerning the incident for at least 7 years. Training Records Records of PCB/Hazardous Waste Training must be maintained for each employee until at least three years from the date on which the person is no longer employed by any of the NEES Companies. Contingency and Emergency Response Plan A Contingency and Emergency Response Plan must be available at the facility. This document is to be updated when necessary and reviewed at least annually. PCB/Hazardous Waste Training Plan The PCB/Hazardous Waste Training Plan must be available at the facility. WASTEWATER Ordinances File a copy of the local sewer ordinance. Permits Maintain any required water use or discharge permits. Wastewater Data Keep any analytical data resulting from sampling by you or the sewer authority. Backflow Devices Retain the permit for the annual Inspection and Maintenance design data sheets of the device. completed by water supplier. UNDERGROUND STORAGE TANKS Registration Forms Annual Reports a backf low device as well as Reports, as -built plans and Keep any inspection reports Closure Information This includes notifications to the state and local fire department and any site assessment work, analytical data, disposal of contaminated soil. Operating Records Maintain records of tightness testing and other inspection methods, inventory data, and maintenance information. Manufacturer Information Keep information concerning tank and piping design, construction and materials. Tank Upgrade Information_ Keep records of all tank upgrades taken to meet state regulations. Releases Keep records of any releases or suspected releases including the response taken, analytical data, and government notifications and correspondence. HAZARDOUS SUBSTANCE, HEALTH & SAFETY Accident Reports The Company maintains employee accident reports, including reports of injuries resulting from overexposure to hazardous substances. Whenever an event takes place such as a spill, leak or other occurrence where exposure to a hazardous substance is a potentiality, the employee is provided the opportunity to receive medical attention. If an employee develops signs or symptoms associated with a hazardous substance overexposure, medical attention is provided. The records of these medical examinations or consultations are kept by the Company for at 30 years after the employee has left the NEES Companies. Copies of the accident reports are maintained at the facility and/or at the District office. APPENDIX E Emergency Response Procedure z O Q U LL H O z w U) Q w I w Cc U z w cc w 2 w U w J aa. w CO cr O (n or Q z Q w J 0 W W W cc Co V oc R z w 2 O U) z Q EMERGENCY RESPONSE PROCEDURE FOR A RELEASE OVER THE REPORTABLE QUANTITY (GENERALLY 10 GALLONS ONTO LAND OR ANY QUANTITY INTO WATER INCLUDING WETLANDS, PONDS, STREAMS, ETC.) * UPON DISCOVERY OF SPILL, CONTACT CLEAN HARBORS (800 -OIL -TANK) AND RANSOM ENVIRONMENTAL (508-465-1822) * WITHIN TWO HOURS OF SPILL DISCOVERY, NOTIFY BUSINESS HOURS NON -BUSINESS HOURS DEP NORTHEAST REGION STATE POLICE (617-935-2162) (800-525-5555) LOCAL LEPC (c/o LOCAL FIRE DEPT) (508-686-3812) IF SPILLED MATERIAL REACHES WATER, CONTACT THE NATIONAL RESPONSE CENTER (800-424-8802) * CONTACT THE EPA (617-565-3279) WITHIN 24 HRS IF ANY OF THE FOLLOWING ARE RELEASED: > 50 ppm PCB MODF INTO WATER OR ONTO GRAZING LAND, VEGETABLE GARDEN, OR FARMLAND; OR 2,700 GALS OR MORE OF > 50 ppm PCB MODF; OR 270 GALS OR MORE OF >499 ppm PCB MODF; ONE-TENTH GALLON OR MORE OF ASKAREL. EMERGENCY RESPONSE PROCEDURE INTRACOMPANY NOTIFICATIONS * DICK HARDING, PCB SPILL COORDINATOR * SABRINA LEWIS, DIVISION ENVIRONMENTAL ENGINEER WRITTEN NOTIFICATION * PCB/HAZARDOUS MATERIAL RELEASE INCIDENT REPORT - GENERATED BY ENGINEER WHO RESPONDED TO THE SPILL - COPY TO: DICK HARDING, PCB SPILL COORDINATOR CARL LEMIESZ, WESTBORO T&D PCB COORDINATOR JOSEPH KWASNIK, WESTBORO ENVMNTL AFFAIRS SABRINA LEWIS, DIVISION ENVIRONMENTAL_ENGR - WITHIN 7 DAYS OF THE INCIDENT, THE PCB SPILL COORDINATOR WILL FORWARD A COPY TO THE DEP AND THE LEPC * ENVIRONMENTAL CONSULTANT'S LETTER REPORT - PROVIDED TO DEP AND LEPC BY PCB SPILL COORDINATOR APPENDIX F Emergency Action -Plan - - EMERGENCY ACTION PLAN FOR MASSACHUSETTS ELECTRIC COMPANY 1101 TURNPIKE STREET NORTH ANDOVER December 17, 1992 TABLE OF CONTENTS I EMERGENCY ACTION PLAN . . . . . . . . . . . . . Page 1 II EVACUATION PROCEDURE . . . . . . . . . . . . . . . Page 3 III EMERGENCY EVACUATION PERSONNEL . . . . . . . . . . Page 8 IV EVACUATION ROUTE AND EMERGENCY EQUIPMENT MAPS . . . Page 11 V ASSEMBLY AREA MAP . . . . . . . . . . . . . . . . . Page 17 VI FIRE PREVENTION PLAN . . . . . . . . . . . . . . . Page 19 VII FIRE EXTINGUISHER CHECKLIST . . . . . . . . . . . . Page 21 December 17, 1992 SECTION I EMERGENCY ACTION PLAN - 1 - December 17, 1992 EMERGENCY ACTION PLAN This document has been prepared to cover actions the company and employees must take to ensure employee safety in the event of an emergency. The District Manager or designee is responsible for implementing and updating the plan. The Plan will be reviewed with each employee: (1) whenever the employees' responsibilities or designated actions change under the plan, and (2) whenever the plan is changed. There will be a review of the Plan with each employee by the Department Head prior to an annual practice evacuation drill. The Emergency Action Plan will be on file with each Department Head, the Personnel Manager and the District Manager. For further information about the Plan contact the District Manager's office on extension 1342 or Mike Rodgers on extension 1444. - 2 - December 17, 1992 SECTION II EVACUATION PROCEDURE - 3 - December 17, 1992 EVACUATION PROCEDURE -MASSACHUSETTS ELECTRIC COMPANY 1101 Turnpike Street North Andover, Massachusetts GENERAL: These instructions will be followed in the event of an emergency requiring an immediate and complete evacuation of personnel in the building in an orderly manner as directed by the monitors. NOTIFICATION: ADD'L NOTIF: The type of emergencies that might require this action are bomb threats, fire, weather or hazardous waste spill. Information on an emergency at the facility should immediately be reported to the following: Richard A. Harding Dennis E. Snay Personnel Dept. Emer. Coordinator District Mgr. ext. 1440, 1441 ext. 1472 ext. 1354 or ext. 1442 (603)898-5588 (H) {508)838-7324 (H) (617)841-1255 (Pgr) (508)683-9452 (Pvt) (508)989-2476 (Car) (508)989-2467 (Car) In the event Dennis Snay is individual should be contacted: William S. McDade, Manager ext. 1341 (508) 683-9435 (Pvt) (603)926-9432 (H) unavailable the following The Personnel Department will then call the following: North Andover Fire Department (508)686-3812 and/or North Andover Police Department (508)683-3168 Bomb Threat: Peter Davidian - Westboro ext. 2633 John Dickson - Westboro ext. 3100 Home: (617) 449-3265 Private: (508) 366-0208 Car: (508) 935-8851 Dennis Mahoney ext. 1447 Home: (508) 683-0263 Private: (508) 683-9536 Car: (508) 989-2803 == December 17, 1992 ADDITIONAL NOTIFICATION: (continued) Mike Rodgers ext. 1444 Home: (603) 642-7788 Pager: (617) 669-8701 Phil Kerkhoff ext. 1489 Home: (603) 778-042 Hazardous Waste: H. D. Burgess ext. 1350 Home: (508) 465-9211 Pager: (617) 669-8717 Car: (508) 989-2333 R. L. Rosentrater ext. 1350 Home: (508) 683-9598 Pager: (617) 669-8717 Car: (508) 989-2320 ALARM SIGNAL: Upon Emergency Coordinator's and/or District Manager's determination that an emergency requires evacuation, Personnel will be notified to sound the alarm. The signal for evacuation will be a series of 15 -second blasts of the building siren system. This will indicate that all personnel should evacuate the building under the direction of the monitors. If the emergency requires the Garage Building evacuation, Personnel will notify Bob Hughes on ext. 1427. ''EMPLOYEE ACTION: The primary evacuation routes and exit numbers are posted on the walls of each floor. Each employee should familiarize themselves with this plan. Emergency Evacuation Personnel (See Section III) will be provided alternate route and exit maps which they will discuss with the employees in their assigned area on an annual basis. Employees leaving the main building using the rear exits (EXITS I, IV, V, VII) will assemble in the rear corner of the upper parking lot next to the transformers. Employees leaving the main building using the front and side exits (EXITS II, III, VI) will assemble in the middle of the grass area beyond the flag pole. If the grass area is not accessible due to snow, the assembly point will be in the rear of the lower parking lot next to the pole yard. - 5 - December 17, 1992 ;MPLOYEE ACTION: Employees from the Stockroom building will assemble in (continued) the rear corner of the upper parking lot next to the transformers. -- - Garage employees will assemble in the rear of the lower parking lot next to the pole yard. Employees who are not at their usual work area or visitors in the building will join the nearest groups in the area and precede to exit under the guidance of that group Monitor. See Section V to reference Assembly Areas on site plans. ALL CLEAR - The District Manager's office, along with Personnel, will make the determination when it is safe to return to the building. Depending on the nature of the event, this decision may also involve the Fire Department (Fire or Bomb Threat) or the Emergency Co-ordinator (Hazardous Waste). The "ALL CLEAR" will consist of a series of seven 5 - second signals. At that time, employees will return to their normal work locations. EMERGENCY Monitors and assistant monitors will be responsible for XACUATION the orderly evacuation .of all personnel in their areas, PERSONNEL: as specified in the Emergency Evacuation Personnel section of this document, from the initial evacuation alarm until the "ALL CLEAR" signal sounds. The monitor and assistant monitor will accompany their group to and from the assembly area via approved routes. The monitor and assistant monitor will be made aware of any handicapped employees or those with special medical restrictions in his or her assigned areas when the plan is implemented and annually thereafter. The assistant monitor will be assigned to ensure the safe evacuation of these individuals. Searchers, working under instructions from the monitors, will check to ensure all personnel are vacated in all rooms in their assigned areas including, but not limited to, locker rooms, restrooms, storage rooms and conference rooms. December 17, 1992 EMERGENCY The Searcher, upon determination that all personnel have EVACUATION been vacated in his or her assigned area, will report PERSONNEL: this information to the monitor. This determination will (continued) be the means to ensure all employees have been accounted. POWER SHUTDOWN: The Facility Manager will make the determination on whether electrical power should be disconnected. In order to de -energize the facility, the Facility Manager will open the main switch in the Switchgear Room prior to evacuating. Since this action automatically turns on the emergency generators, he will then precede to the parking lot area behind the Relay Department to manually de -energize control pads #1 and #2. The Chief Dispatcher will put the automatic control of the emergency generator for the Dispatch Center to the "non -auto" position prior to evacuation. This will prevent the operation of the emergency generator for the Dispatch Center. SAFETY: In order to carry out the above procedure with a maximum of safety, all personnel shall leave the areas to be evacuated as directed by the Monitors in an orderly manner, walking in pairs. Under certain conditions, the normal lighting of the building may be extinguished during such emergencies, and adherence to the provision of this paragraph is absolutely necessary. - 7 - December 17, 1992 SECTION III EMERGENCY EVACUATION PERSONNEL - 8 - December 17, 1992 EMERGENCY EVACUATION PERSONNEL AREA A: CUSTOMER SERVICE EXIT I Monitor: R. Lothrop Alternate: T. Latina Act. Monitor: A. Jenne Alternate: S. McEvoy Searcher: N. Terrio Alternate: A. Masiello AREA B: DST. MANAGEMENT; MEETING ROOM; CASHIERS; CUSTOMERS EXIT II Monitor: W. McDade Alternate: R. Dowling Act. Monitor: L. McSweeney Alternate: M. Baxter AREA C: CUSTOMER RELATIONS; METER RDG: MEETING ROOMS; MAILROOM; MAINTENANCE MEN'S ROOM EXIT III Monitor: T. Ryan Alternate: H. Hill Act. Monitor: P. Murphy Alternate: I. Anderson Searcher: C. Brandt Alternate: AREA D: C&I/C&LM; MEN'S & LADIES' ROOM EXIT I Monitor: W. Sherry Alternate: R. Brady Act. Monitor: W. Bowen Alternate: A. Johnson Searcher: J. Upham Alternate: M. Doherty AREA E: DST. T&D; MEDICAL: CAFETERIA, TELEPHONE OPERATOR EXIT IV Monitor: D. Mahoney Alternate: R. Harding vI Act. Monitor: C. McGinness Alternate: J. Clark Monitor for Cafeteria: J. Kellilea December 18, 1992 'REA F: METER DEPARTMENT EXIT IV Monitor: J. Denham Alternate: P. Kus AREA G: T&D LOCKER ROOM EXIT V Monitor: R. Salvati Alternate: R. Wilkins AREA H: DIV. DISPATCH; TROUBLE CENTER EXIT VII Monitor: W. Callahan Alternate: W. Burkhardt AREA I: DIV. PERSONNEL; DIV. T&D; LADIES'_ ROOM EXIT IV Monitor: J. Hudson Alternate: M. McCallan Asst. Monitor: L. L'Heureux Alternate: A. McLellan Searcher: G. Meagher Alternate: G. Dwyer AREA J: 112 DFE; 1/2 DIV. ENGR; MENS' ROOM EXIT IV Monitor: C. Loth Alternate: P. Kerkhoff Asst. Monitor: D. Ellsworth Alternate: R. Wheeler Searcher: D. McCarthy Alternate: J. Guimond AREA K: 1/2 DFE; 1/2 DIV. ENGR EXIT V Monitor: F. Kippen Alternate: R. Pickering Asst. Monitor: F. Antczak Alternate: R. Moore AREA L: STORES; C&C; RELAY: MENS' & LADIES' ROOM Monitor: P. Canney Alternate: L. Roy Asst. Monitor: S. Parsons Alternate: M. Lister Searcher: D. O'Connell Alternate: F. Bean AREA M: GARAGE Monitor: R. Hughes Alternate: T. Eaton Searcher: M. Coughlin Alternate: P. Carlin - 10 - December 17, 1992 SECTION IV EVACUATION ROUTE MAPS AND EMERGENCY EQUIPMENT MAPS =11= December 17, 1992 W uj cc W ri d' tj Be cc O O —i W cl z N cr 0 WQ >W Occ zQw Q z (j�O z OC Oa® U�— U w Q cr-}U F°'VQ UZ> Www WO cf) W Q� W I- 0 z Y Q a V) w LU E E o c o ww Li LL I— wo r W r V i nnavrn � Z X OW w �O t c Q W O W G 0 Ly 0 cc ? w o w Z_ J =/ ,=I— w F' Zw J Q H w cc LL !L1 :7co ? D a X o W / � X4d a w E 0 c � ww Li LL I— :7co ? D a X o W / � X4d a riw X w w LL K� \l V4 Li �14 A I I f•�-i--i I J r--y-� I tr a_ pp< 3 J 9z F"Ow� 3 tr a_ pp< O 0 C w F"' H = w Zo aw O Q y J w W WLL t Y Q /Qy� K F< /Qi1�. W V Mj 9z SECTION V ASSEMBLY AREA MAP - 17 - December 17, 1992 e 1' Z-4 v y 1 M R W 4wnia I W¢ \ SECTION VI FIRE PREVENTION PLAN - 19 - December 17, 1992 FIRE PREVENTION PLAN EVACUATION: See Section II - Evacuation Procedure Page 4 ALARM SYSTEM: The Facility Manager will conduct a test of. the alarm system every 2 months to ensure reliability and adequacy. He/she will maintain a record of these tests and will keep them in his/her office. FIRE EXTINGUISHERS: A fire extinguisher checklist can be found in Sections VII. At lease one individual from each area listed on the Emergency Evacuation Personnel list will be trained on the safe use of a fire extinguisher. The training will take place annually and a description of the training program and the individuals attending will be kept by the Facility Manager. See Emergency Equipment Maps on Pages 12-16 for Fire Extinguisher locations. - 20 - December 17, 1992 SECTION VII FIRE EXTINGUISHER CHECKLIST - 21 - December 17, 1992 EXTN # 1 2 3 4 5 6 7 8 9 EXTN # 10 11 12 13 14 15 EXTN # 16 17 18 19 20 21 EXTN # 22 23 24 MAIN OFFICE BUILDING FIRST FLOOR TYPE & SIZE ABC - DRY CHEM - 5 LBS BC - CO2 - 20 LBS ABC - DRY CHEM - 5 LBS ABC - DRY CHEM - 5 LBS ABC - DRY CHEM - 5 LBS ABC - DRY CHEM - 5 LBS ABC - DRY CHEM - 5 LBS ABC - HALON - 9 LBS ABC - HALON - 9 LBS TYPE & SIZE LOCATION MACHANICAL RM, AT OFFICE DOOR MACHANICAL RM, INSIDE DOOR # 111 MACHANICAL RM, INSIDE DOOR # 111 HALLWAY AT WTR FOUNTAIN BY MAIL RM INSIDE DOOR AUDITORIUM "A" ON LEFT METER READING BY DOOR # ELEVATOR FOIURE AREA BY CUST SERV CUST SERV BY DOOR # 132 CENTER CUST SERV ON COLUMN SECOND FLOOR ------------ BC - DRY CHEM - 30 LBS ABC - DRY CHEM - 5 LBS ABC - DRY CHEM - 5 LBS ABC - DRY CHEM - 5 LBS ABC - DRY CHEM - 5 LBS ABC - DRY CHEM - 5 LBS TYPE & SIZE ABC - DRY CHEM - 5 LBS ABC - DRY CHEM - 5 LBS ABC - DRY CHEM - 5 LBS ABC - HALON - 17 LBS ABC - HALON - 17 LBS ABC - HALON ' - 5 LBS TYPE & SIZE ---------------------- BC - CO2 - 20 LBS BC - CO2 - 20 LBS BC - CO2 - 20 LBS LOCATION TRANSFORMER RM, INSIDE DOOR LINE LOCKER RM, INSIDE DOOR # 249 HALLWAY BY DOOR # 245 METER DEPT INSIDE DOOR # 257 HALLWAY OUTSIDE CAFE BY HEALTH SERV C & I SERV BY HALLWAY DOOR THIRD FLOOR LOCATION HALLWAY BY DOOR # 345 ELEVATOR FOIURE BY PENTHOUSE DOOR IN TROUBLE CTR BY KITCHEN DOOR NE DISPATCH, BREAK RM NE DISPATCH, BREAK RM NE DISPATCH PENTHOUSE LOCATION ----------------------------------- AT FAN UNIT - AC 3 NORTH HEAD OF STAIRS BY AT FAN UNIT - AC 3 SOUTH SURPLUS ABC - DRY CHEM - 5 LBS STORED IN BOILER RM SURPLUS ABC - DRY CHEM - 5 LBS STORED IN BOILER RM SURPLUS ABC - DRY CHEM - 5 LBS STORED IN BOILER RM SURPLUS ABC - DRY CHEM - 5 LBS STORED IN BOILER RM - 22 - EXTN # i TYPE & SIZE 25 BC - PURPLE K - 30 LBS 26 ABC - DRY CHEM - 5 LBS 27 ABC - DRY CHEM - 5 LBS 28 BC - PURPLE K - 30 LBS 29 BC - PURPLE K - 30 LBS 30 ABC - DRY CHEM - 5 LBS 31 BC - PURPLE K - 5 LBS 32 33 ABC - DRY CHEM - 5 LBS 34 ABC - DRY CHEM -20 LBS WAREHOUSE LOCATION INSIDE DOOR TO LINE GARAGE INSIDE DOOR OF THE C & C DEPT INSIDE DOOR OF THE RELAY DEPT STORES BATTERY CHARGER AREA BY THE LINE DEPT STORAGE CAGE OUTSIDE DOOR TO STORES OFFICE AREA LOADING DOCK AREA WAREHOUSE BY LOADING DOCK DOORS INSIDE STORES BY DOOR # STORES ALLEYWAY AREA - 23 - EXTN # TYPE & SIZE ------- ---------------------- 35 BC - PURPLE K - 30 LBS 36 BC - CO2 - 20 LBS 37 BC - CO2 - 20 LBS 38 BC - PURPLE K - 30 LBS 39 BC - DRY CHEM - 20 LBS 40 ABC- DRY CHEM - 20 LBS SURPLUS A - SURPLUS BC - CO2 - 5 LBS SURPLUS BC - PURPLE K - 5 LBS SURPLUS BC - PURPLE K - 5 LBS SURPLUS GARAGE LOCATION OUTSIDE SOLVENT BATH AREA AIR STATION AIR STATION OUTSIDE WASHBAY DOOR PARTS RM FUEL SERVICE ISLAND STORED IN PARTS RM STORED IN PARTS RM STORED IN PARTS RM STORED IN PARTS RM STORED IN PARTS RM - 24 - J APPENDIX G New England Electric.System Companies Emergency Release Notification Chemical Fact Sheets August 17, 1992 NEW ENGLAND ELECTRIC SYSTEM COMPANIES 1. TRADE NAME: EMERGENCY RELEASE NOTIFICATION CHEMICAL FACT SHEET Diesel Fuel Oil 2. CHEMICAL NAME: Hydrocarbon Mixture 3. DOT HAZARDOUS SUBSTANCE AND DOT NUMBER: Yes - NA 1993 4. EXTREMELY HAZARDOUS SUBSTANCE: No 5. NEES COMPANIES REPORTABLE QUANTITY: Water - any quantity, land -10 gallons (This is the amount of material that would have to be released to trigger NEES Companies reporting requirements) 6. MAXIMUM STORAGE AMOUNT: 7. POSSIBLE MEANS OF RELEASE: Liquid Spill Air Surface Water X Groundwater X Land X 8. HEALTH RISKS: Vapors harmful, irritating to skin, eyes and respiratory system Acute Nausea, dizziness, irritant Chronic Skin cancer Special Medical Attention: Flush exposed areas with water for 15 minutes Do not induce vomiting 9. PROPER RESPONSE PRECAUTIONS: Safety Precautions: Ventilate area shut off ignition sources, spray to reduce vapors Personal Protection: Gloves, protective suit, goggles. In case of fire SCBA Safe Distance Zone: Keep unnecessary persons away, isolate area, stay upwind. If large tank, tank car or truck is involved in a fire evacuate in a 1/2 mile radius 10. PROPER RESPONSE TECHNIQUES: Spill Containment: Contain with non-combustible adsorbent material or dike Fire Fighting: Cool containers with water, fight fire with dry chemical, foam, CO2, water Neutralization: Not applicable Cleanup and Disposal: Dispose of as a hazardous waste 11. SOURCES OF INFORMATION: MSDS,1984 DOT Emergency Response Guidebook, Dangerous Properties of Industrial Materials August 17, 1992 NEW ENGLAND ELECTRIC SYSTEM COMPANIES EMERGENCY RELEASE NOTIFICATION CHEMICAL FACT SHEET 1. TRADE NAME: Exxon Regular Gasoline 2. CHEMICAL NAME: Gasoline 3. DOT HAZARDOUS SUBSTANCE AND DOT NUMBER: Yes UN 1203 4. EXTREMELY HAZARDOUS SUBSTANCE: No 5. NEES COMPANIES REPORTABLE QUANTITY: Water - any quantity, land -10 gallons (This is the amount of material that would have to be released to trigger NEES Companies reporting requirements) 6. MAXIMUM STORAGE AMOUNT: 7. POSSIBLE MEANS OF RELEASE: Liquid Spill Air Surface Water X Groundwater X Land X 8. HEALTH RISKS: Vapors harmful - irritating to skin, eyes and respiratory system Art [fp Headaches, dizziness, irritant Chronic Liver, kidney damage, dermatitis Special Medical Attention: Do not induce vomiting Flush exposed areas with water for 15 minutes 9. PROPER RESPONSE PRECAUTIONS: Safety Precautions: Ventilate area shut off ignition sources, spray to reduce vapors Personal Protection: Gloves, protective suit, goggles. In case of fire SCBA Safe Distance Zone: Keep unnecessary persons away, isolate area, stay upwind. If large tank, tank car or truck is involved in a fire evacuate in a 1/2 mile radius 10. PROPER RESPONSE TECHNIQUES: Spill Containment: Contain with non-combustible adsorbent material or dike Fire Fighting: Cool containers with water, fight fire with dry chemical, foam, CO2 Neutralization: Not applicable Cleanup and Disposal: Dispose of as a hazardous waste 11. SOURCES OF INFORMATION: MSDS, 1984 DOT Emergency Response Guidebook, Toxic and Hazardous Industrial Chemical Safety Manual. Dangerous Properties of Industrial Materials, Handbook of Toxic and Hazardous Chemicals August 17, 1992 NEW ENGLAND ELECTRIC SYSTEM- COMPANIES EMERGENCY RELEASE NOTIFICATION CHEMICAL FACT SHEET 1. TRADE NAME: AC Mineral Spirits 1-5 No. 627 Solvent 2. CHEMICAL NAME: Petroleum Solvent 3. DOT HAZARDOUS SUBSTANCE AND DOT NUMBER: Yes - UN 1993 4. EXTREMELY HAZARDOUS SUBSTANCE: No 5. NEES COMPANIES REPORTABLE QUANTITY: Ten gallons (This is the amount of material that would have to be released to trigger NEES Companies reporting requirements) 6. MAXIMUM STORAGE AMOUNT: 7. POSSIBLE MEANS OF RELEASE: Uquid Spill Air Surface Water X Groundwater X Land X 8. HEALTH RISKS: Irritating to skin, eyes, mucous membranes and respiratory system Acute Headaches, dizziness, irritant Chronic Dermatitis Special Medical Attention: Flush exposed areas with water for 15 minutes Do not induce vomiting 9. PROPER RESPONSE PRECAUTIONS: Safety Precautions: Ventilate area, shut off ignition sources, spray to reduce vapors Personal Protection: Gloves, protective suit, goggles. In case of fire SCBA -Safe Distance Zone: Keep unnecessary persons away, isolate area, stay upwind. If large tank, tank car or truck is involved in a fire evacuate in a 1/2 mile radius---- 10. PROPER RESPONSE TECHNIQUES: Spill Containment: Contain with non-combustible adsorbent material or dike Fire Fighting: Cool containers with water, fight fire with dry chemical, foam, CO2, water Neutralization: Not applicable Cleanup and Disposal: Dispose of as a hazardous waste 11. SOURCES OF INFORMATION: MSDS, 1984 DOT Emergency Response Guidebook, Dangerous Properties of Industrial Materials August 17, 1992 NEW ENGLAND ELECTRIC SYSTEM COMPANIES EMERGENCY RELEASE NOTIFICATION CHEMICAL FACT SHEET 1. TRADE NAME: S61 Silicone Transformer Liquid 2. CHEMICAL NAME: Silicone 3. DOT HAZARDOUS SUBSTANCE AND DOT NUMBER: 4. EXTREMELY HAZARDOUS SUBSTANCE: No No 5. NEES COMPANIES REPORTABLE QUANTITY: See Sec. 7 of the Hazardous Waste and (This is the amount of material that would have to be PCB Procedures Manual released to trigger NEES Companies reporting requirements) 6. MAXIMUM STORAGE AMOUNT: 7. POSSIBLE MEANS OF RELEASE: Liquid Spill Air Surface Water X Groundwater X Land X 8. HEALTH RISKS: Irritation to skin, eyes _ Acute Irritation to skin, eyes Chronic Special Medical Attention: Flush exposed areas with water for 15 minutes 9. PROPER RESPONSE PRECAUTIONS: Safety Precautions: Ventilate area Personal Protection: Gloves, apron, goggles. In case of fire SCBA Safe Distance Zone: Keep unnecessary persons away 10. PROPER RESPONSE TECHNIQUES: Spill Containment: Contain with adsorbent material or dike Fire Fighting Fight fire with dry chemical, foam, CO2, water Neutralization: Not applicable Cleanup and Disposal: Dispose of as a waste oil according to regulations 11. SOURCES OF INFORMATIONS MSDS, 1984 DOT Emergency Response Guidebook, Dangerous Properties of Industrial Materials r� August 17, 1992 NEW ENGLAND ELECTRIC SYSTEM COMPANIES EMERGENCY RELEASE NOTIFICATION CHEMICAL FACT SHEET 1. TRADE NAME: Univolt 60 2. CHEMICAL NAME: Petroleum Electrical Insulating Oil 3. DOT HAZARDOUS SUBSTANCE AND DOT NUMBER: No 4. EXTREMELY HAZARDOUS SUBSTANCE: No 5. NEES COMPANIES REPORTABLE QUANTITY: 10 gallons or see Sec. 7 of the NEES Hazardous Waste and PCB Procedures Manual (This is the amount of material that would have to be released to trigger NEES Companies reporting requirements) 6. MAXIMUM STORAGE AMOUNT: 7. POSSIBLE MEANS OF RELEASE: Liquid Spill Air Surface Water X Groundwater X Land X 8. HEALTH RISKS: Irritating to skin, eyes and respiratory system Acute Headaches, dizziness, irritant Chronic Dermatitis Special Medical Attention: Flush exposed areas with water for 15 minutes Do not induce vomiting 9. PROPER RESPONSE PRECAUTIONS: Safety Precautions: Ventilate area shut off ignition sources, spray to reduce vapors Personal Protection: Gloves, protective suit, goggles. In case of fire SCBA Safe Distance Zone: Keep unnecessary persons away, isolate area, stay upwind. If large tank, tank car or truck is involved in a fire evacuate in a 1/2 mile radius 10. PROPER RESPONSE TECHNIQUES: Spill Containment: Contain with non-combustible adsorbent material or dike Fire Fighting: Cool containers with water, fight fire with dry chemical, foam, CO2, water Neutralization: Not applicable Cleanup and Disposal: Dispose of as a waste oil 11. SOURCES OF INFORMATION: MSDS, 1984 DOT Emergency Response Guidebook, Dangerous Properties of Industrial Materials August 17, 1992 NEW ENGLAND ELECTRIC SYSTEM COMPANIES EMERGENCY RELEASE NOTIFICATION CHEMICAL FACT SHEET 1. TRADE NAME: PCB Fluid 2. CHEMICAL NAME: Polychlorinated Biphenyls 3. DOT HAZARDOUS SUBSTANCE AND DOT NUMBER: Yes - UN 2315 4. EXTREMELY HAZARDOUS SUBSTANCE: No 5. NEES COMPANIES REPORTABLE QUANTITY: One Ib. or see Sec. 7 of NEES Hazardous (This is the amount of material that would have to be Waste and PCB Procedures Manual released to trigger NEES Companies reporting requirements) 6. MAXIMUM STORAGE AMOUNT: 7. POSSIBLE MEANS OF RELEASE: Liquid Spill Air Surface Water X Groundwater X Land X 8. HEALTH RISKS: Irritating to eyes and mucous membranes, carcinogen Acute Irritant, chloracne Chronic Liver damage, carcinogen, embryotoxic Special Medical Attention: Flush exposed areas with water for 15 minutes If ingested, give saltwater and induce vomiting 9. PROPER RESPONSE PRECAUTIONS: Safety Precautions: Ventilate area. Prevent spread of spill and contamination Personal Protection: Gloves, full protective suit, goggles, SCBA Safe Distance Zone: Keep unnecessary persons away, isolate area 10. PROPER RESPONSE TECHNIQUES: Spill Containment: Contain with adsorbent material and dike area Fire Fighting: . Fight fire with dry chemical, foam, CO2, water dike water for disposal Neutralization: Not applicable Cleanup and Disposal: Waste and all materials and equipment used in cleanup must be disposed of as a PCB waste according to regulations 11. SOURCES OF INFORMATION: MSDS, 1984 DOT Emergency Response Guidebook, Dangerous Properties of Industrial Materials, Handbook of Toxic and Hazardous Chemicals