HomeMy WebLinkAboutMiscellaneous - Exception (560)TIM ANGELOSANTO (603) 595.8559 Vice -President FAX (603) 886-7317 tim@eastemvent.com Eastern Vent SystenUl Inc. HVAC Sheet Metal Fabrication & Installation S Commercial, Industrial 4 Dick Tracy Dr www.easternvent.com Pelham, NH 03076 July 31, 2013 DESIGN DAY MECHANICALS INC The Commonwealth Of Massachusetts State Building Code Final HVAC Construction Control Affidavit Project: Brightview Living Center 1275 Turnpike Street North Andover, Massachusetts Engineer: David E. Goddard, P.E. Design Day Mechanicals, Inc. 1 Mapleleaf Drive, Nashua, NH 03062 In accordance with Section 116.0 of the Massachusetts State Building Code, I, David E. Goddard Registration No. 31095, being a registered Professional Engineer, hereby certify that Andrew W. Arsenault, my assigned representative from Design Day Mechanicals, Inc. (DDMI) has been present on the construction site to determine that the work is proceeding in accordance with the documents approved for the Building Permit, as required in Section 116.2:2, item 3 as outlined below. July 31, 2013 - Observed installation of equipment and grilles/diffusers in A, B and C wings. Final installations are either complete or are proceeding, subject to finish painting and final wiring of equipment, as shown on the pertinent aroved DDMI drawings. Testing and balancing is A 44 proceeding where power is avails _.010 A. Respectfully submitted, ITS°% DAVID E. 31095 David E. Goddard, P.E. President, Der i TfUdy Mechanicals, Inc. Professional Engineer #31095 David E. Goddard, P.B • I Mapleleaf Drive, Nashua, NH 03062 • (603) 888-1632 • davidegoddard@live.com Douglas C. Waitt 0 P,O. Box 447, New Ipswich, NH 03071 • (603) 291-0111 dougwoitt@comcost.net Richard D. Gagnon 0 84 Gilford Street, Manchester, NH 03102 • (603) 668-5027 rdgjhg@comcast.net John L. Woitt 0 148 Beaver Ridge Road, Center Barnstead, NH 03225 • (603) 269-7253 jlwdd@tds.net DESIGN DAY MECHANICALS INC March 8, 2013 To: Ron Gagnon All -Temp HVAC Corp. 119 Candia Road Manchester, NH Re: Brightview 1275 Turnpike Road North Andover, Massachusetts The ductwork is properly sealed and is adequate for demonstrating compliance with the prevailing energy codes. The final test and balance report shall certify that the systems have been tested and satisfactorily meet their performance requirements. Respectfully, .s" OF DAVID E. David E. Goddard, P.E.' PTHident, Design Day Mechanicals, inc. Professional Engineer #31095 David E. Goddard, P.E 1 Mopleleaf Drive, Nashua, NH 03062 • (6031888-1632 • davidegoddard@live.com Douglas C. Waitt P.O. Box 447, New Ipswich, NH 03071 • (6031291-0111 • dougwdti@comcast.net Richard D. Gagnon • 84 Gilford Street, Manchester, NH 03)02 . (603) 668-5027 • rdging@comcast.net John L. Waitt 148 Beaver Ridge Road, Center Barnstead, NH 03225 • (603) 269-7253 • jlwdd®tds.net March 7, 2013 DESIGN DAY MECHANICALS INC The Commonwealth Of Massachusetts . State Building Cale Construction Control Affidavit Project: Brightview 1275 Turnpike Road North Andover, Massachusetts Engineer: David E. Goddard, P.E. Design Day Mechanicals, Inc. 1 Mapieleaf Drive, Nashua, NH 03062 In accordance with Section 116.0 of the Massachusetts State Building Code, I, David E. Goddard Registration No. 31085, being a registered Professional Engineer, hereby certify that Douglas C. Mitt, my assigned representatives from Design Day Mechanicals, Inc. (DDMI) has been present on the construction site to determine that the work is proceeding in accordance with the documents approved for the Building Permit, as required in Section 116.2.2, item 3 as outlined below. March 4, 2013 Observed roughen ductwork on first, second and third floor within Area B, and rough -in corridor ductwork systems on the first, second and third floor within Area A and B , as shown on the pertinent approved DDMI drawings. Ductwork was properly fabricated, installed and sealed. Insulation ;?O�AVDE cr'bed above can proceed as required. Respectfully subm too. 31095 David E. Goddard, P. . Day Mechanicals, Inc. Professional Engineer #31055 December 17, 2012 Project: Engineer: DESIGN DAY MECHANICALS INC The Commonwealth Of Massachusetts State Building Code Construction Control Affidavit Brightview 1275 Turnpike Road North Andover, Massachusetts David E. Goddard, P.E. Design Day Mechanicals, Inc. 1 Mapleleaf Drive, Nashua, NH 03062 In accordance with Section 116.0 of the Massachusetts State Building Code, I, David E. Goddard Registration No. 31095, being a registered Professional Engineer, hereby certify that Douglas C. Waitt, my assigned representatives from Design Day Mechanicals, Inc. (DDMI) has been present on the construction site to determine that the work is proceeding in accordance with the documents approved for the Building Permit, as required in Section 116.2.2, item 3 as outlined- below. utlinedbelow. November 26, 2012 Observed rough -in ductwork within Area C, as shown on approved DDMI drawings M -1.1C, 1.2C, 1.3C and 1.4C. Ductwork was properly fabricated, installed and sealed, and, properly insulated.,�WM'A4'd, Respectfully submitted, David E. Goddard, P.E. Professional Engineer #31095 iicals, Inc. David E. Goddard, P.E 1 Mapleleaf Drive, Nashua, NH 03062 (603) 888.1632 • dWo�egodWr4d@rive.com Douglas C. Want P.O. Box 447, New Ipswich, NH 03071 (603) 291-0111 • dougwoift@comccst.net Richard 0. Gagnon • 84 Gilford Street, Manchester, NH 03102 • (603) 668-5027 . rdg)hg@oomcast.net John L. Watt . 148 Beaver Ridge Rood, Center Bornsteod, NH 03225 . (603) 269-7253 • liwdd@tcis.net HOOD T.A.B. LLC HVAC TESTING & BALANCING SERVICE PO BOX 3271 Andover, MA 01810 Phone 978-474-7595 Fax 978-474-7596 DUCT LEAKAGE TEST REPORT PROJECT: Bright View - North Andover ENGINEER: Design Day Mechanicals CONTRACTOR: Eastern Vent PROJECT# : 2013107 Feld Technicians: Date: Approved MWH 3/15/13 Michael W. Hoo H00D T.A.B. LLC HVAC TESTING & BALANCING SERVICE PO BOA 3271 Andover, MA 01810 Phone 978-474-7595 Fax 978-474-7596 DUCT LEAKAGE TESTING PROCEDURE 1. Select a test pressure. ? Calculate the allowable leakage using SMACNA procedures 3. Select a section of duct. 4. Connect the blower and flo Armeter to the duct section. 5. Pressurize the duct section to the required level. 6. Read the flowmeter and compare the leakage to allowable rates. 7. Record all steps during testing TEST INSTRUMENTS (+) ORIFLOW C I TESTER {) AIR PATTERN SMOKE PUFFER O MAGNAHELIC GAUGE 0"-2" (+) PRESSURE DIFFERENTIAL GAUGE {) DIFF. PRESSURE METER () MAGNAHELIC GAUGE 0"-.25" O MAGNAHELIC GAUGE 0"-5" {) MAGNAHELIC GAUGE 0- 10 TEST RESULTS Hood TAB tested the supply duct work On the first floor. See attached drawing for shaded duct runs and segments that were tested. The segment tested passed. ES 0 6.2 HVAC Air Duct Leakage Test Manual • First Edition .S=AGNA f � J j Q O w U r zQ n , U Oo a 1 I - v 3 fv 0i j 1 f<o v I 2 U i I V < x 2 v � < L) U �+3 D t�:Z, Irl LL TS zr r -T75 D O m ( F Y^ HVAC Air Duct Leakage Test Manual • First Edition .S=AGNA V la Calibration Certificate OK1FZOW Colibnnwn Labomlon Clenrwnler, Raridd We+stie: www ortfl,­ cm Picone dumber. t'323),'30-7589 . Email: eVnee#ng@odAow.com Customer orifice plate was calibrated using ORIFLOW test procedure OTP-TM-1105. Calibration equipment is traceable to NIST. Estimated accuracy is +1- 2%, ninety-five percent uncertainty Calibration Date: 05121 q0 Orifice 1D7 Lo in Material. 304 SS Office Serial #: 60(" Test Method: OTP-Tib1-1105 "ORIFICE TUBE" Gauge Reading in. Leakage Rate cfm 0.0 0.0 0.1 4.4 0.2 6.2 0.3 7.6 0.4 8.8 0.5 9.8 0.6 10.7 0.7 11.6 0.8 12.4 0.9 13.1 1.0 13.9 1.1 14.5 1.2 15.2 1.3 15.8 1.4 t6.4 1.5 17.a 1.6 17.5 Standard temperature and pressure "ORIFICE TUBE" Gauge Reading in.w ..MITI) Leakage Rate 1 7 18.1 1.8 18.6 1.9 19.1 2.0 19.6 2.1 20.1 2.2 20.6 2.3 21.0 2.4 21,5 2.5 21.9 2.6 22.3 2.7 22.8 2.8 232 2.9 23.6 3.0 24.0 3.1 24.4 32 24.8 3.3 25.2 "ORIFICE TUBE' Gauge heading in.w .. Leakage Rate m 3.4 25.6 3,5 25.9 3.6 .26.3 3.7 26.7 3.8 27.0 3.9 27.4 4.0 27.7 4.1 28.1 42 28.4 4,3 28.7 4.4 29.1 4.5 29.4 4.6 29.7 4.7 30.0 4.8 30.4 4.9 30 5.0 31.0 You may use a calculator to calculate leakage using the "ORIFICE TUBE gauge reading and the following equation. Leakage (cfm) = 13.86 x V ORIFICE TUBE Gauge Reading � s Calibration Technicia?r 3( Ile s' Calibration Certificate OkIPLOA C:ahbranoa i4hunitan (Womater, hlorrdo webstic: k°k'k.Or izlk'.4YN3; Plywe Number (323) 230-75,W Errall enginee6n9@0dBow-com Customer orifice plate was calibrated using ORIFLOW test procedure OTP-TW1105. Calibration equipment is if to MST. Estimated accuracy is +1- 20/6, ninety-five percent uncertainty. Caflbration Date: 05/21110 Orfce ID: 4 () in- Material: 304 SS Orrice Seria( # 609-4 Test Method: OTP-TAI 1105 "ORIFICE TUBE" Gauge Reading In.w .. leakage Rate cfm 0.0 0.0 0.1 100.4 0,2 142.0 0.3 173.9 0.4 200.8 0.5 224.5 0.6 245.9 0.7 265.6 0.8 284.0 0.9 301.2 1.0 317.5 1.1 333.0 1.2 347.8 1.3362.0 5494 1.4 375.6 1.5 388.8 1.6 401.6 Standard temperature and pressure "ORIFICE TUBE` Gauge Reading (in. ..) Leakage Rate cfrn 1.7 413.9 1.8 425.9 1.9 437.6 2.0 449.0 2.1 460.1 2.2 470-9 2.3 481.5 2.4 491.8 2.5 502.0 2.6 511.9 2.7 521.7 2.8 531.2 2.9 540.6 10 5494 3-1 559.0 3.2 567.9 3.3 576.7 "ORIFICE TUBE" Gauge Reading gin. Leakage Rate cfm 3.4 .585.4 3.5 593.9 3.6 602.4 3.7 610.7 3.8 618.9 3.9 627.0 4.0 634.9 4.1 642.8 4.2 650.6 4.3 658.3 4.4 .665.9 4.5 673.5 4.6 680.9 4.7 686.3 4.8695.5 4.9 702.7 5,p 709.9 You may use a calculator to calculate leakage using the "ORIFICE TUBE" gauge reading and the following equation: Leakage (cfm) = 317.47 x+1 ORIFICE TUBE Gauge Reading 0 t �s T nical ger J Y r�� r�� ►�� r+ W_ Calibration Certificate OHN-_L )W Calthroaon l ahuraron (.'leawater, Honda IJ,C& e. %"," oriflrm,snn Phonr Mumlwr 023/230-75" Email: engineering@oriflow.com Customer orifice plate was calibrated using ORIFLOW test procedure OTP-TM-1105. Calibration equipment is traceable to NIST. Estimated accuracy is +l- 2%, ninety-five percent uncertainty. Calibration Date: 05/21J10 0fife ID: 3.0 jr?. Material: 304 SS Orrice Serial #: 608-3 Test Method: OTP-T ,1-1105 "ORIFICE TUBE" Gauge Reading in.w .. Leakage Rate cfm 0.0 0.0 0.1 45.5 0.2 64.4 0.3 78.9 0.4 91 1 0.5 101.8 Q.6 111.5 0.7 120.5 0.8 128.8 0.9 136.6 1.0 144.0 1.1 151.0 1.2 157.7 1.3 164.2 1.4 170.4 1.5 176.3 1.6 182.1 Standard temperature and pressure "ORIFICE TUBE" Gauge Reading in.w .. Leakage Rate cfm 1.7 187.7 1.8 193-2 1,9 198.5 2.0 203.6 2.1 208.6 2.2 213.6 2.3 218.4 2.4 223.1 2.5 227.7 2.6 232.2 2.7 236.6 2.8 240.9 2.9 245.2 3.0 249A 3.1 253.5 3.2 257.6 3.3 261.6 - "ORIFICE TUBE" Gauge Reading in.w .. Leakage Rate cim 3.4 265.5 3.5 269.4 3.6 273.2 3.7 277.0 3.8 280.7 3.9 284.3 4.0 288.0 4.1 291.5 4.2 295.1 4.3 298.6 4.4 302.0 4.5 305.4 4.6 308.8 4.7 312.1 4.8 1 15.4 4.9 318.7 5.0 321.9 You may use a calculator to calculate leakage using the "ORIFICE TUBE" gauge reading and the following equation: Leakage (cfm) = 143.98 x ORIFICE TUBE Gauge Reading Calibration Technics r�. '�i ��� r�� r*� r�„ roti r,t #�� �� �*= r*� r*� r*r r*s r*�► �*s r�� >.,r' � Calibration Certificate r NFL W Calrbnrarut lahorown Cleanrater, Honda Websae, xwutrrm.rnttr Phan Nxmher: (313) 230- ?J89 Email' engineedrig@orf low.oam Customer orifice plate was calibrated using ORI FLOW test procedure OTP-TM-1105. Calibration equipment is traceable to NtST. Estimated accuracy is +1- 2%, ninety-five percent uncertainty. Calibration Date: 05,'21/10 Orifice 1D: 2 0 in Material: 304 SS Orifce serial i# 601-2 test Method OTT-TA9 /105 ".ORIFICE TUBE" Gauge Reading in.w .. Leakage Rate cfm 0.0 0.0 0.1 18.6 0.2 26.4 0.3 32.3 0.4 37,3 0.5 41.7 0.6 45.7 0.7 49.3 0.8 52.7 0.9 55.9 1.0 59.0 1.1 61.8 1.2 64.6 1-3 67.2 1.4 69.8 1,5 72.2 1.6 74.6 Standard temperature and pressure "ORIFICE TUBE" Gauge Reading in.w .. Leakage Rate Wm) 1.7 76.9 1.8 79.1 1.9 81.3 2.0 83.4 2.1 85.4 2.2 87.5 2.3 89.4 2.4 91.3 2.5 93.2 2.6 95.1 2.7 96.9 2.8 98.7 2.9 100.4 3.0 . 102,1 3.1 103.8 3.2 105.5 3.3 107.1 "ORIFICE TUBE" Gauge Reading in.w .. Leakage Rate cfrn 3.4 108.7 3.5 110.3 3.6 111.9 3.7 113.4 3.8 114.9 3.9 116.4 4.0 117.9 4.1 119.4 4.2 120.8 4.3 122.3 4.4 123.7 4.5 125.1 4.6 126.5 4.7 127.8 4.8 129.2 49 130.5 5.0 131.8 You may use a calculator to calculate leakage using the "ORIFICE TUBE" gauge reading and the following equation: Leakage (cfm) = 58,96 x ORIFICE TUBE Gauge Reading r�p y Catibrafw T ech _"D61 Manager June 18, 2013 DESIGN DAY MECHANICALS INC The Commonwealth Of Massachusetts State Building Code Construction Control Affidavit Project: Brightview 1275 Turnpike Road North Andover, Massachusetts Engineer: David E. Goddard, P.E. Design Day Mechanicals, Inc. 1 Mapleleaf Drive, Nashua, NH 03062 In accordance with Section 116.0 of the Massachusetts State Building Code, I, David E. Goddard Registration No. 31095, being a registered Professional Engineer, hereby certify that Douglas C. Waitt (DCW), my assigned representatives from Design Day Mechanicals, Inc. (DDMI) has been present on the construction site to determine that the work is proceeding in accordance with the documents approved for the Building Permit, as required in Section 116.2.2, item 3 as outlined below. June 5, 2013 - DCW observed the rough —in ductwork for the commercial kitchen, as shown on the pertinent approved DDMI drawings. Ductwork was properly fabricated, installed and sealed. Insulation of the ductwork described above can proceed as required. Respectfully submitted, David E. Goddard, P.E. Professional Engineer #31095 )Is, Inc. David E. Goddard, P.E 1 Mapleleaf Drive, Nashua, NH 03062 4 (603) 888-1632 davidegoddard0live.com Douglas C. Waitt P.O. Box 447, New Ipswich, NH 03071 (603) 291-0111 dougwaitt@comcast.net Richard D. Gagnon 84 Gilford Street, Manchester, NH 03102 • (603) 668-5027 rdgjhg@comcast.net John L Waitt 148 Beaver Ridge Road, Center Barnstead, NH 03225 (603) 269-7253 jiwdd@tds.net HOOD T.A.B., LLC HVAC TESTING & BALANCING SERVICE PO BOX 3271 Andover, MA 01810 Phone 978-474-7595 Fax 978-474-7596 DUCT LEAKAGE TEST REPORT PROJECT. Brightview - North Andover CONTRACTOR: Eastern Vent PROJECT #: 2013080 Field Technicians: Date: Approved : MWH 4 6/ /13 V Michael W. Hood WIMAAF�� HOOD 1A b, 012-17U-O7Explrar,. 4127il-I NTATIoKAt WANCING co*L 'Cll ," r)>. z or-> Ij z 0 r) Z "Z> CD 0- cn r- rQ 0 CD bC tS 0 tn M -4 1p C) 4 HOOD T.A.D•, LLC HVAC TESTING & BALANCING SERVICE PO BOX 3271 Andover, MA 01810 Phone 978-474-7595 Fax 978-474-7596 A leakage test for the Welded Kitchen exhaust ductwork was performed on all longitudinal seams and transverse joints utilizing the following method. MAGNAFLUX SPOTCHECK DEVELOPER SPOTCHECK is a RED VISIBLE nondestructive test method for Liquid Penetrant Inspections (LPI). This type of inspection is one of the most widely used methods that reveal SURFACE cracks and other discontinuities in virtually any NON -POROUS material both ferrous and non-ferrous. FEATURES and BENEFITS • Ideal for applications where portability is required • Very economical when compared to other nondestructive methods • Vivid red color that permits daylight inspection • Meets major specifications, both military and nuclear • Manufactured with high quality solvents that will produce the smallest indications that may be missed by other products • ISO 9000 certified manufacturing facility APPLICATIONS SPOTCHECK provides accurate, reliable crack detection results in the following applications: • Automotive parts • Welds • Castings • Forgings • Leak Testing • Power Plant Inspections • Pressure Vessels • Aircraft Maintenance (in some non-critical applications) • Marine Maintenance • Petroleum Pipelines • General Metalwork Upon completion of the leakage test, a light test was also performed by passing an open 100 watt lamp through the inside of the entire duct system. TEST RESULTS All seams and joints were visually inspected on the outside to determine if any light was emitting through the welds. No leaks were detected during either testing method. PRO CON# INCORPORATED Design and Construction Management January 29, 2013 Mr. Gerald Brown — Inspector of Buildings Town of North Andover 1600 Osgood St. North Andover, MA 01845 978-688-9545 Re: Brightview Senior Housing 1275 Turnpike Street, North Andover, MA Final Structural Affidavit for C -Wing Dear Mr. Brown, To the best of my information, knowledge and belief, "C -wing" of the Project stated above has been constructed in accordance with plans and specifications prepared under my supervision. Sincerely, Matthew . LaBrecque, PE Structural Engineer of Record - Pro Con Inc cc: Mike Callihan Dan Messier Erik Anderson 0)` Mgss cy 9 O MATTHElN J. G g LAf-3RECQUE STRUCTURAL Cn No. 43104 �o�9FGIS7 SSI0NAL Design Professionals Seal PRO CON, INC. A Stebbins Company P.O. Box 4430 Manchester, NH 03108 603.623.8811 Fax 603.623.7250 www.proconinc.com