Loading...
HomeMy WebLinkAboutMiscellaneous - Exception (698)C SEP- 3-92 THU 15;22 ELKINS COFFEE INSTALLATION INSTRUCTIONS Electrical Data for GEM -12 FAX N0. 6032254709 Single Phase 3 Wire + Ground Voltage Required: 2201230 Volts. Power Consumption: 29 Amps at 220V 27 Amps at 230V 6300 Watts Circuit Breaker Capacity: 40 Amps 30 Amps Minimum. Three Phase 3 Wire & Three Phase 4 Wire. Voltage Required: 208/220 Volts. Power Consumption: 17.5 Amps at 208V 16,6 Amps at 220V 6300 Watts Circuit Breaker Capacity: 20 Amps Minimum. Single Phase 2 Wire Supplied with Step -Dawn Transformer 220/110 Volts or Single Phase 2 Wire with All Electrical Components for 220V, Voltage Required: 2081220 Volts, Power Consumption: 30 Amps at 208V 28.6 Amps at 220V 6300 Watts Circuit Breaker Capacity: 40 Amps 30 Amps Minimum. Electrical Data For GEM -230A Single Phase 3 Wire Voltage Required: 220/230 Volts. Power Consumption: 19 Amps at 220V 18.2 Amps at 230V 4175 Watts Circuit Breaker Capacity: 20 Amps Single Phase 2 Wire Supplied with Step -Down Transformer 220/110 Volts or Single Phase 2 Wire with All Electrical Components for 220V. Voltage Required. 2201230 Volts. Power Consumption: 19 Amps at 220V 18.2 Amps at 230V 4175 Watts Circuit Breaker Capacity: 30 Amps 20 Amps Minimum NOTE: Read Serial Plate For Power Requirements Power Supply Connections Single Phase 3 Wires Do Not Use Less Than #10AWG Li Power Supply ;fires Brewer Wires Red Neutral T. 4 22 Voles White L2 *00 110Volls 4 Blue T Three Phase 3 Wires Do Not Use Less Than #12AWG L1 j Red L2 _ 4 208,r220V 4 Black Striped L3208122.0V t 2081220V glue y 1 WARNING S HELL OF BREWER MUST BE GROUNDED SECURELY TO PREVENT SHOCK. FAR THIS P1;RPOSE, A GROUNDING GREEN SCREW IS PROVIDED INSIDE ELECTRICAL BV? page 3 P. 05