Loading...
HomeMy WebLinkAboutMiscellaneous - Lot 24 Boxford Streetr f a e P he Neve-MorinT Group, Inc. August 6, 2008 Ms. Susan Sawyer, R.S./R.E.H.S. Health Director 1600 Osgood Street North Andover, MA 01845 Re: Lot 24, Boxford Street (Map 105A, Parcel 24) Dear Ms. Sawyer: RECEIVED AUG 1 1 2008 TOWN OF/TM OVER HEALTH D4 — Please find enclosed copies of the soil evaluation forms and a sketch plan showing the location for the soil testing that was conducted at the above -referenced property on August 5, 2008. If you should have any questions regarding any of this information please do not hesitate to contact our office. Sincerely, THE NEVE-MORIN GROUP, INC. _A 0-�o4v44— Greg J. Hochmuth, R.S. Environmental Planner GJH/kmm Enclosures cc: Peter & .Kerry Breen F:`.KATHYM\Breen 684\Lct 24`•.NABH Ltr Soil Eval Forms.doc ENGINEERS • SURVEYORS • ENVIRONMENTAL CONSULTANTS • LAND USE PLANNERS 447 Old Boston Road (U.S. Route 1), Topsfield, MA 01983 978-887-8586 FAX 978-887-3480 Providing Professional Services Since 1978 www.nevemorin.com No. 684.2,4 FORM 11— SOIL EVALUATOR FORM Pagel of 3 Commonwealth of Massachusetts North Andover, Massachusetts Date: 8/6/08 Soil Suitability Assessment for On-site Sewaze Disposal Performed By: Greg Hochmuth Date: 8/5/08 Witnessed By: Isaac Rowe Date: 8/5/08 Location Address or Owner's Name Peter & Kerry Breen Lot # Lot 24 Boxford Street Address and 770 Boxford Street (Formerly Lot 9 Ogunquit) North Andover, MA 01845 (Map 105A, Parcel 24) Telephone # 978-687-7774 New Construction 0 Repair Office Review Published Soil Survey Available: No = Yes 0 Year Published 1981 Publication Scale V= 1320' Drainage Class B Soil Limitations Surficial Geologic Report Available: No 0 Year Published Publication Scale Geologic Material (Map Unit) Landform Kame Yes Flood Insurance Rate Map: Above 500 year flood boundary No Yes X Within 500 year flood boundary No X Yes Within 100 year flood boundary No X Yes Wetland Area: National Wetland Inventory Map (map unit) Wetlands Conservancy Program Map (map unit) Current Water Resource Conditions (USGS): Month Range: Above Normal Normal 0 Below Normal Other References Reviewed: Soil Map Unit CcC FORM 11 — SOIL EVALUATOR FORM Page 2 of 3 Location Address or Lot No. Lot 24 Boxford Street (Formerly Lot 9 Ogunquit Road ) On -Site Review Deep Hole Number 08-1 Date 8/5/08 Time 9:00 am Weather Sunny 70T Location (identify on site plan) See Plan Land Use Residential Slope (%) 0-3 Surface Stones Few Vegetation Scant Landform Ground Moraine Position on landscape (sketch on the back) Distances from: See Plan Open Water Body NA feet Drainage Way Possible Wet Area >100 feet Property Line Drinking Water Well >100 feet Other NA feet >10 feet *MINIMUM OF 2 HOLES REQUIRED AT EVERY PROPOSED DISPOSAL AREA Parent Material (geologic) Glacial Till Depth to Bedrock: NA Depth to Groundwater: Standing Water in the Hole: 110" Weeping from Pit Face: 110". Estimated Seasonal High Ground Water: 28" DEP APPROVED FORM —12/7/95 DocumenC DocumenU Depth from Surface (Inches) Soil Horizon Soil Texture (USDA) Soil Color (Munsell) Soil Mottling Other (Structure, Stones, Bounders, Consistency, % Gravel 0-28" 28-114" Fill C - LS - 2.5Y5/6 Yes ESHWT @ 28 *MINIMUM OF 2 HOLES REQUIRED AT EVERY PROPOSED DISPOSAL AREA Parent Material (geologic) Glacial Till Depth to Bedrock: NA Depth to Groundwater: Standing Water in the Hole: 110" Weeping from Pit Face: 110". Estimated Seasonal High Ground Water: 28" DEP APPROVED FORM —12/7/95 DocumenC DocumenU I FORM 11— SOIL EVALUATOR FORM Page 3a of 3 Location Address or Lot No. Lot 24 Boxford Street (Formerly Lot 9 Ogunquit Road) Determination for Seasonal Hirh Vater Table OP 08-1 Method Used: Depth observed standing in observation hole inches Depth weeping from side of observation hole inches X Depth to soil mottles 28 inches Groundwater adjustment feet Index Well Number Adjustment factor Reading Date Index Well Level Adjusted ground water level Depth of Naturally Occurring Pervious Material Does at least four feet of naturally occurring pervious material exist in all areas observed throughout the area proposed for the soil absorption system? Yes If not, what is the depth of naturally occurring pervious material? Certification I certify that on 11/13/03 I have passed the soil evaluator examination approved by the Department of Environmental Protection and that the above analysis was performed by me consistent with the required training, expertise and experience described in 310 CMR 15.017. Signature Date g 1 d og DEP APPROVED FORM — 12/7/95 Document6 lJ : d d ooleo0oo, EL O / / C? to a`\� — O Cb 0 Cl a O , . 4