HomeMy WebLinkAbout2013-09-03 Planning Board Supplemental Materials (7) DJKDermot J. Kelly Associates, Inc. Traffic Engineering/Transportation Planning 6 Cameron Road Andover, MA 01810 978-664-2205 MEMORANDUM TO: Mr. Jeffrey Sheehy FROM: Dermot J. Kelly, PE, PTOE Dundee Properties, LLC DJK Associates, Inc. PO Box 3099 6 Cameron Road Andover, MA 01810 Andover, MA 01810 SUBJECT: 102 Peters Street REF: 822-Mem6-Parking North Andover, MA Parking Accumulation Study DATE: August 22, 2013 Peak Parking Accumulation Study On Wednesday August 21, 2013 a Peak Parking Accumulation Study was conducted between 7:00 and 9:00 AM at the Robins Nest Daycare facility located at 1608 Bridge Street, Dracut, MA. This facility is similar to the Proposed Daycare facility to be located at 102 Peters Street in North Andover, MA in the way the parking lot will operate. At both the existing Robins Nest Daycare facility and the Proposed Daycare facility, parking for parental arrivals and departures occurs in front of the building. A total of 35 vehicles were observed to arrive at the Robins Nest Daycare facility during the two hour study period between 7:00 and 9:00 AM, 3 staff vehicles and 32 parental vehicles. Fifty- eight children were signed-in to the facility that day, 48 before 9:00 AM. A maximum of seven vehicles were observed parked on-site between 7:00 and 9:00 AM. The seven vehicles were observed on three occasions over a total of 5 minutes and 34 seconds. If the observed parking data were adjusted to account for the proposed 39 children Daycare facility then the projected peak parking demand would be 5 vehicles (39 projected children/58 children observed x 7 maximum observed vehicles = 5 maximum projected vehicles). In either case, a maximum of 5 or 7 vehicles parked on-site can easily be accommodated since the proposed facility has 11 parking spaces available on-site. DJKDermot J. Kelly Associates, Inc. Traffic Engineering/Transportation Planning APPENDIX—Peak Parking Accumulation Study 8/22/13; 2 of 3 822-Memo6 w-Appendix Robins Nest Daycare Date: Wednesday 8/21/2013 Parking Lot Turnover Study Time: 7:00am-9:00am 1608 Bridge Street PDI File# 133483 Dracut, MA Client: DJK/D. Kelly Client#: 822 Robins Nest Daycare Parking Lot Turnover Study Vehicle# Entered Lot Left Lot Delay Cars Notes in sec. in Lot 1 7:00:00 AM 1 Staff 2 7:04:27 AM 7:08:24 AM 03:57 2 3 7:04:48 AM 7:08:07 AM 03:19 3 4 7:07:23 AM 7:08:54 AM 01:31 4 5 7:08:33 AM 7:11:03 AM 02:30 3 6 7:14:25 AM 2 Staff 7 7:15:35 AM 7:16:16 AM 00:41 3 8 7:16:02 AM 7:22:59 AM 06:57 4 9 7:19:12 AM 7:23:11 AM 03:59 4 10 7:22:18 AM 7:23:27 AM 01:09 5 11 7:24:25 AM 7:28:08 AM 03:43 3 12 7:27:31 AM 7:28:22 AM 00:51 4 13 7:33:07 AM 7:37:10 AM 04:03 3 14 7:34:50 AM 7:42:11 AM 07:21 4 15 7:36:53 AM 7:46:08 AM 09:15 5 16 7:36:54 AM 7:45:01 AM 08:07 6 17 7:40:21 AM 7:45:11 AM 04:50 6 18 7:40:41 AM 7:41:03 AM 00:22 7 19 7:43:57 AM 7:45:46 AM 01:49 7 20 7:48:19 AM 7:49:24 AM 01:05 3 21 7:53:33 AM 7:55:47 AM 02:14 3 22 7:53:52 AM 8:03:10 AM 09:18 4 23 7:59:30 AM 4 Staff 24 7:59:41 AM 8:09:03 AM 09:22 5 25 8:03:30 AM 8:07:54 AM 04:24 5 26 8:03:37 AM 8:21:40 AM 18:03 6 27 8:04:16 AM 8:09:54 AM 05:38 7 28 8:14:25 AM 8:34:24 AM 19:59 5 29 8:15:27 AM 8:16:03 AM 00:36 6 30 8:17:42 AM 8:21:18 AM 03:36 6 31 8:26:19 AM 8:29:47 AM 03:28 5 32 8:27:17 AM 8:29:24 AM 02:07 6 33 8:32:54 AM 8:41:13 AM 08:19 5 34 8:38:30 AM 8:39:37 AM 01:07 5 35 8:57:14 AM 8:59:32 AM 02:18 4 Total Vehicles (Staff& Parents): 35 Vehicles Max. #of Parked Vehicles In Lot(Staff& Parents): 7 Vehicles C:WII DJK FIIesWctive Jobs\Job Word\822 Dundee, North Andover, MA\PDI\822-Dracut Peak Parking Accumulation Study.xlsx;8/22/2013 8/22/13; 3 of 3 822-Memo6 w-Appendix