HomeMy WebLinkAbout2013-02-28 Board of Health Agenda Packet LJR Engineering, Inc. CIA Engineers and Land Surveyors 234 Park Street North Reading,MA 01864 (978)664-8149 Fax(978)664.8142. Email:1roy @Ijren91neoring.com February 15, 2013 North Andover Board of Health 1600 Osgood Street Building 20; Suite 2-36 North Andover, MA 01845 RE: Variance Request Septic System Replacement 213 Carlton Lane Map 107A Parcel 208 Dear Board Members: On behalf of the owners,David &Pamela Fowler,we are hereby requesting the following variances from Title 5 and the North Andover Septic Regulations for construction of the above referenced septic system replacement. -To reduce the setback distance of the soil absorption system to a wetland resource area as stipulated in Section 11 3.9 of the North Andover Regulations,from I00ft, to 50ft. -To reduce the required separation between the bottom of the soil absorption system and the high groundwater elevation from 4ft.to 3ft. (Local upgrade approval 310CMR 15..405(l)(11)). -To allow for a sieve analysis to be performed because a percolation test in accordance with 310 CMR 15.104 and 15.105 can not be performed (Local upgrade approval 310 CMR 15.405(1)). -To allow for less than the required two deep holes per disposal area as required by 310 15.102 (Local upgrade approval 15.405(1)(k)). Thank you for your consideration of this request. We understand this request will be heard at the February 28,2013 Board of Health meeting. If there are any questions or if any additional information is required, please call our office. Thank you. Sincerely, Luke J. Roy,P.E.