Loading...
HomeMy WebLinkAbout2012-07-17 Planning Board Supplemental Materials (52)99-ft Self-Supporting Pole Structure (Concealed Monopole) VSi Project 121203, Revision 0 June 12, 2012 TowerCo No. MA2010 Page 2of 2 2002 Production Drive, Apex, NC 27539 Ph: (888) 321-6167 Fax: (919) 321-1768 admin@verticalsolutions-inc.com June 12, 2012 Subject Rigorous Structural Analysis Carrier Designation Sprint/Nextel,Reconfiguration Site Number: BS54XC860 Site Name: N/A TowerCo Designation Site Number: MA2010 Site Name: Steven’s Estate Engineering Firm Designation Vertical Solutions Project: 121203,Revision 0 Site Data 723 Osgood Street,North Andover,EssexCounty,MA01845 Latitude: N42°42'28.30"±; Longitude: W071°06'51.48"± Elevation: 252ft±, Topography Category: 1; Exposure Category: “C”; Structure Class II;Site Class “D” 99-ft Self-Supporting Pole Structure (Concealed Monopole) Dear Ms. Godwin, To your request, we present our structural analysis. Our work indicates that with the proposed appurtenance configuration, the tower willnot satisfy the structural strength requirements of ANSI/TIA-222-G-2-2009,Structural Standard for Antenna Supporting Structures and Antennas –Addendum 2 (industry standard) and the 2009InternationalBuilding Code (local building code) for: 100-mph three-second gust basic wind speed 40-mph three-second gust basic wind speed with 1-in radial ice Earthquake design parameters and loading, per USGS Ground Motion Parameter Calculator and industry standard, respectively, including: o Ss = 0.329,S1 = 0.075 However, foundation stress level is acceptable. We trust you find our work satisfactory. Please do not hesitate to call should you have any questions. Sincerely, Kingsley C. Igboanugo, E.I.Michael L. Lassiter, S.E., P.E., C.W.I. Structural Engineer-In-TrainingStructural Engineer, Civil Engineer, Certified Weld Inspector & President Reviewed by: JHWMA License No. 47314 Ms. Catherine Godwin TowerCo, LLC 5000 Valleystone Drive Cary, NC 27519 (919) 653-5737 Vertical Solutions, Inc. PO Box 579 Holly Springs, NC 27540 (888) 321-6167 operations@verticalsolutions-inc.com FAIL (CanisterPipe,123%capacity) 06/12/2012 99-ft Self-Supporting Pole Structure (Concealed Monopole) VSi Project 121203, Revision 0 June 12, 2012 TowerCo No. MA2010 Page 2 of 2 2002 Production Drive, Apex, NC 27539 Ph: (888) 321-6167 Fax: (919) 321-1768 admin@verticalsolutions-inc.com Table 1: Existing, Proposed and Reserved Appurtenance Configuration Elevation (AGL, ft) Carrier Mount Equipment Coax Location1 99 - - 25’x15’ Flag - - 97.02 Sprint/Nextel Inside 53” Canister (3) RFS APXVSPP18-C-A20 (3) 1900 RRH (65 MHz) (3) 800 RRH (3) External Notch Filter (6) 1900 ACU-A20-N (3) 800 ACU-A20-N (3) 1 1/4 Inside 88.0 AT&T Inside 28” Canister (3) KMW AM-X-CD-14-65-00T-RET (3) CCI Twin Triple Band PCS TMA (1) Kaelus Triplexer (6) 1 5/8 Inside 76.0 T-Mobile Inside 20” Canister (3) EMS DR65-19-00DPQ (6) LNAs (6) 7/8 Inside 1 – See coax configuration plan, QP-P for coax locations. 2 – Antenna wind area was not considered in the analysis. Table 2: Serviceability Requirements: Limit State Deformations1 Elevation (AGL, ft) Equipment Twist (deg)2 Sway (deg)2 Deflection (in) Deflection Limit (in)3 Result 99 Structure 0.0000 7.1528 39.878 35.64 N. G. 1 – See program output for supporting details. 2 – Per TIA-222-G Section 2.8.2.1 rotation about the vertical axis (twist) or any horizontal axis (sway) of the structure shall not exceed 4 degrees. 3 – Per TIA-222-G Section 2.8.2.2 horizontal displacement shall not exceed 3% of the height of the structure. Table 3: Tower Structure Results, Percent Capacity Utilized1 Elevation (ft) Shaft Result Connections Result 99 to 89 69 O. K. - - 89 to 79 94 O. K. - - 79 to 69 123 N. G. 45 O. K. 69 to 23.26 78 O. K. - - 23.26 to 0 98 O. K. 107 N. G. 1 – Utilization of 105% or less considered acceptable Table 4: Foundation Results, Percent Capacity Utilized Component Design Analysis Percent Utilized Result Soil 16’ caisson 13.50’ caisson 84 O. K. Structure 18 #8 = 14.22 in2 10.68 in2 75 O. K. Attachments: • Project History • Coax Configuration Plan, Sheet QP-P • Program Input and Output • Base Plate and Anchor Rod Calculations • Flange Plate and Flange Bolt calculations • Foundation Calculations Pr o j e c t H i s t o r y Page 1of 3 VS i P r o j e c t # : 1 2 1 2 0 3 , R e v i s i o n 0 To w e r C o S i t e I d : M A 2 0 1 0 To w e r C o S i t e N a m e : S t e v e n ’ s E s t a t e De s i g n  Do c u m e n t s To w e r C o   Do c u m e n t St r u c t u r e Is s u e d   Da t e Do c u m e n t  ID Is s u e d  By Is s u e d  To Description 30 0 6 7 2 MA 2 0 1 0 4/ 2 3 / 2 0 0 2 20 0 2 0 4 2 3 _ G E O _ M A 2 0 1 0 . p d f Ja w o r s k i   Ge o t e c h ,  In c Sp r i n t Geotechnical Investigation 30 0 6 6 3 MA 2 0 1 0 3/ 1 8 / 2 0 0 3 20 0 3 0 3 1 8 _ T F D D _ M A 2 0 1 0 . p d f En g i n e e r e d   En d e a v o r s  In c . Sp r i n t Tower and Foundation Design Drawings 30 0 6 6 2 MA 2 0 1 0 3/ 2 9 / 2 0 0 3 20 0 3 0 3 2 9 _ T D D _ M A 2 0 1 0 . p d f En g i n e e r e d   En d e a v o r s  In c . Sp r i n t Tower Design Drawings 29 0 0 0 6 MA 2 0 1 0 5/ 3 0 / 2 0 0 3 29 0 0 0 6 _ M A 2 0 1 0  ST E V E N ‐S ES T A T E  AT & T  SL A . p d f Sp r i n t AT & T Site Lease Agreement 45 8 2 5 7 MA 2 0 1 0 5/ 3 0 / 2 0 0 3 45 8 2 5 7 _ M A 2 0 1 0  ST E V E N ‐S ES T A T E  AT & T  SL A . p d f Sp r i n t AT & T Site Lease Agreement 84 7 0 0 2 MA 2 0 1 0 7/ 1 0 / 2 0 0 3 84 7 0 0 2 _ M A 2 0 1 0  St e v e n ‐s Es t a t e  Ca n s i t e r  De t a i l s . p d f En g i n e e r e d   En d e a v o r s  In c . CanisterDetails 28 9 9 8 2 MA 2 0 1 0 2/ 3 / 2 0 0 4 28 9 9 8 2 _ M A 2 0 1 0  ST E V E N ‐S ES T A T E  Co n c r e t e  Te s t . p d f YS C Sp r i n t Concrete Test Report 30 0 6 8 0 MA 2 0 1 0 8/ 1 8 / 2 0 0 4 30 0 6 8 0 _ M A 2 0 1 0  St e v e n ‐s Es t a t e  He i g h t  Ve r i f i c a t i o n  08 ‐18 ‐04 . p d f Sp r i n t Sp r i n t Height Verification Report 28 9 9 8 6 MA 2 0 1 0 9/ 2 3 / 2 0 0 4 28 9 9 8 6 _ M A 2 0 1 0  St e v e n ‐s Es t a t e  Sp r i n t  CD s . p d f Co l e r  & Co l a n   To n i o Sp r i n t Construction Drawings 30 0 7 7 0 MA 2 0 1 0 12 / 1 2 / 2 0 0 6 30 0 7 7 0 _ M A 2 0 1 0  ST E V E N ‐S ES T A T E  Si t e  au d i t  fo r m . p d f Un k n o w n To w e r C o Site Audit 28 9 9 9 9 MA 2 0 1 0 5/ 1 8 / 2 0 0 7 28 9 9 9 9 _ M A 2 0 1 0  ST E V E N ‐S ES T A T E  T‐mo b i l e  SL A . p d f T‐Mo b i l e Sp r i n t Site Lease Agreement 30 0 7 6 4 MA 2 0 1 0 5/ 1 8 / 2 0 0 7 30 0 7 6 4 _ M A 2 0 1 0  ST E V E N ‐S ES T A T E  T‐Mo b i l e  SL A . p d f To w n  of  No r t h   An d o v e r ,  MA Om n i p o i n t   Co m m u n i c a t i o n s Site Lease Agreement 29 0 0 1 6 MA 2 0 1 0 3/ 1 7 / 2 0 0 8 20 0 8 0 3 1 7 _ S A R _ M A 2 0 1 0 . p d f Se m a a n   En g i n e e r i n g   So l u t i o n s T‐Mo b i l e Structural Analysis 30 0 7 6 6 MA 2 0 1 0 3/ 1 7 / 2 0 0 8 30 0 7 6 6 _ M A 2 0 1 0  ST E V E N ‐S ES T A T E  Se m a a n  St r u c t u r a l  An a l y s i s  T‐Mo b i l e   Co L o  03 ‐17 ‐20 0 8  du p l i c a t e . p d f Se m a a n   En g i n e e r i n g   So l u t i o n s Sp r i n t  Si t e s  USA Structural Analysis Report 29 0 0 2 1 MA 2 0 1 0 4/ 1 4 / 2 0 0 8 29 0 0 2 1 _ M A 2 0 1 0  ST E V E N ‐S ES T A T E  Fi r s t  Am e n d m e n t  of  Li c e n s e   Ag r e e m e n t . p d f Sp r i n t Om n i p o i n t   Co m m u n i c a t i o n s Amendment SLA 71 2 4 1 5 MA 2 0 1 0 9/ 2 3 / 2 0 0 8 71 2 4 1 5 _ M A 2 0 1 0  St e v e n ‐s Es t a t e  SL A . p d f To w e r C o Sp r i n t Site Lease Agreement 71 5 4 8 3 MA 2 0 1 0 11 / 1 3 / 2 0 0 8 71 5 4 8 3 _ M A 2 0 1 0  St e v e n ‐s Es t a t e  To w e r  Pr o f i l e . p d f Si t e M a s t e r To w e r C o Tower Profile Drawing Pr o j e c t H i s t o r y . d o c x Page 2of 3 De s i g n  Do c u m e n t s To w e r C o   Do c u m e n t St r u c t u r e Is s u e d   Da t e Do c u m e n t  ID Is s u e d  By Is s u e d  To Description 72 0 2 7 5 MA 2 0 1 0 11 / 1 3 / 2 0 0 8 20 0 8 1 1 1 3 _ T I R _ M A 2 0 1 0 . p d f Si t e M a s t e r To w e r C o Tower Inspection Report 79 6 2 9 1 MA 2 0 1 0 11 / 1 9 / 2 0 0 8 79 6 2 9 1 _ M A 2 0 1 0  St e v e n ‐s Es t a t e  AT & T  St r u c t u r a l  ‐ 11 ‐19 ‐08 . p d f En g i n e e r e d   En d e a v o r s  In c . SA I   Co m m u n i c a t i o n s Structural Analysis Report 79 6 2 9 2 MA 2 0 1 0 6/ 1 7 / 2 0 1 0 79 6 2 9 2 _ M A 2 0 1 0  St e v e n ‐s Es t a t e  AT & T  Si g n e d  an d  Se a l e d  St r u c t u r a l   Le t t e r  ‐   6‐17 ‐10 . p d f De w b e r r y ‐ Go o d k i n d  In c . Sp r i n t Structural Review Email ‐‐ MA 2 0 1 0 7/ 9 / 2 0 1 0 20 1 0 0 7 0 9 _ C T A _ M A 2 0 1 0 . d o c Me t r o  PC S To w e r C o Co‐location Tenant Application 79 8 8 1 9 MA 2 0 1 0 7/ 1 5 / 2 0 1 0 79 8 8 1 9 _ M A 2 0 1 0  St e v e n ‐s Es t a t e  Ve r t i c a l _ S t r u c t u r a l _ A n a l y s i s _ M e t r o   PC S _ C o l l c o a t i o n _ 2 0 1 0 0 7 1 5 . p d f Ve r t i c a l   So l u t i o n s To w e r C o Structural Analysis Report 70 9 3 4 3 MA 2 0 1 0 8/ 2 0 / 2 0 1 0 70 9 3 4 3 _ M A 2 0 1 0  St e v e n ‐s Es t a t e  Si t e  Pl a n . p d f To w e r C o Site Audit 80 8 4 4 6 MA 2 0 1 0 10 / 1 9 / 2 0 1 0 80 8 4 4 6 _ M A 2 0 1 0  St e v e n ‐s Es t a t e  Sp r i n t  Fi r s t  Am e n d m e n t . p d f To w e r C o Sp r i n t Amendment SLA 80 9 9 4 5 MA 2 0 1 0 11 / 5 / 2 0 1 0 80 9 9 4 5 _ M A 2 0 1 0  St e v e n ‐s Es t a t e  Sp r i n t  1s t  Am d  Re n t  Co m m  No t i c e  to   To w e r C o . p d f Sp r i n t To w e r C o Commencement Notice 85 6 5 8 3 MA 2 0 1 0 11 / 2 2 / 2 0 1 0 85 6 5 8 3 _ M A 2 0 1 0  St e v e n ‐s Es t a t e  TI  CO L  fo r  AT & T  Mo d s . p d f Ve r t i c a l   So l u t i o n s To w e r C o Close‐Out Letter ‐‐ MA 2 0 1 0 7/ 2 7 / 2 0 1 1 MA 3 4 6 9 + L T E + C D + R e v + 0 + 5 . 3 1 . 1 1 . p d f At l a n t i s  Gr o u p AT & T Site Audit ‐‐ MA 2 0 1 0 7/ 2 8 / 2 0 1 1 MA 2 0 1 0  SA  Lo a d i n g . x l s To w e r C o Ve r t i c a l  So l u t i o n s SA Loading ‐‐ MA 2 0 1 0 9/ 2 7 / 2 0 1 1 MA 3 4 6 9  To w e r C o  Re c o n f i g u r a t i o n _ A p p l i c a t i o n  RE V I S E D  6‐21 ‐11 . d o c x Ne w  Ci n g u l a r   Wi r e l e s s To w e r C o Reconfiguration Tenant Application 85 2 3 5 3 MA 2 0 1 0 10 / 5 / 2 0 1 1 85 2 3 5 3 _ M A 2 0 1 0  St e v e n ‐s Es t a t e  AT & T  1s t  Am e n d m e n t  to  SL A  Fu l l y   Ex e c u t e d . p d f To w e r C o Ne w  Ci n g u l a r Site Lease Agreement 84 6 4 4 5 MA 2 0 1 0 10 / 2 4 / 2 0 1 1 84 6 4 4 5 _ M A 2 0 1 0  St e v e n ‐s Es t a t e  _V e r t i c a l _ S t r u c t u r a l   An a l y s i s _ A T & T _ R e c o n f i g u r a t i o n _ 1 0 ‐24 ‐20 1 1 . p d f Ve r t i c a l   So l u t i o n s To w e r C o Structural Analysis Report 85 4 4 6 2 MA 2 0 1 0 10 / 2 4 / 2 0 1 1 85 4 4 6 2 _ M A 2 0 1 0  St e v e n ‐s Es t a t e  Ve r t i c a l  TI  Dr a w i n g s  ‐ ca n i s t e r   en l a r g e m e n t ‐  AT & T  Re c o n f i g  10 ‐24 ‐20 1 1 . p d f Ve r t i c a l   So l u t i o n s To w e r C o Tower Improvement Drawings 86 2 7 6 6 MA 2 0 1 0 2/ 2 1 / 2 0 1 2 86 2 7 6 6 _ M A 2 0 1 0  St e v e n ‐s Es t a t e  Em a i l  fr o m  T‐Mo b i l e  Co n f i r m i n g  Re n t   Co m m e n c e m e n t  Da t e . p d f T‐Mo b i l e To w e r C o Email Correspondence ‐‐ MA 2 0 1 0 5/ 7 / 2 0 1 2 NV _ B P  CD ' S _ B S 5 4 X C 8 6 0 . 0 5 . 0 7 . 1 2 _ S 2 0 1 2 5 1 0 1 5 5 9 4 5 7 9 0 . 0 5 . 0 7 . 1 2 . p d f Hu d s o n  De s i g n   Gr o u p Sp r i n t Construction Drawings ‐‐ MA 2 0 1 0 6/ 6 / 2 0 1 2 MA 2 0 1 0  Sp r i n t  Ne t w o r k  Vi s i o n  SA  Lo a d i n g . x l s To w e r C o Ve r t i c a l  So l u t i o n s SA Loading Pr o j e c t H i s t o r y . d o c x Page 3of 3 De s i g n  Do c u m e n t s To w e r C o   Do c u m e n t St r u c t u r e Is s u e d   Da t e Do c u m e n t  ID Is s u e d  By Is s u e d  To Description ‐‐ MA 2 0 1 0 6/ 6 / 2 0 1 2 NV _ B S 5 4 X C 8 6 0 _  Re l o  Ap p  MA 2 0 1 0  Sp r i n t  Re c o n f i g u r a t i o n   Ap p l i c a t i o n . d o c Sp r i n t To w e r C o Reconfiguration Tenant Application Ta b l e N o t e : Fi l e s n a m e f o r m a t Y Y Y Y M M D D - X X X - Z Z Z Z Z Z . p d f Wh e r e : Y Y Y Y M M D D = Y e a r , M o n t h , D a y p u b l i s h e d / i s s u e d X X X = f i l e d e s c r i b e r Z Z Z Z Z Z = T o w e r C o S i t e I D (3) 1 1/4 TO 97 FT (SPRINT/NEXTEL) (6) 1 5/8 Tn 44 CT A(INSIDE) = 143 SQ IN A (COAX) = 29.74 SQ IN FILL RATIO = 20.79% COAX CONFIGURATION PLAN AT 69 -FT SCALE: 3" = 1'-0" PROJECT INFORMATION: STEVEN'S ESTATE SITE M MA2010 723 OSGOOD STREET NORTH ANDOVER, MA 01845 (ESSEX COUNTY) DRAWN BY: KCI CHECKED BY: JHW SHEET NUMBER: REVISION: QP-PV51 #: 12 1203 (6) 7/8 TO 76 FT (T -MOBILE) PLANS PREPARED FOR: -� 5000 Valleystone Drive 7519 Tower+Co Cary, 9) 69-5 Office (919) 469-5559 Fax (919) 469-5530 PLANS PREPARED BY: vertical 2002 Production Drive r lutions Apex, 27539 Office: (888)8) 321-6167 Fax: (919) 321-1768 0 06- 11- 12 TowerCo, LLC. REV DATE: Issued For: DRAWN BY: KCI CHECKED BY: JHW SHEET NUMBER: REVISION: QP-PV51 #: 12 1203 (6) 7/8 TO 76 FT (T -MOBILE) PLANS PREPARED FOR: -� 5000 Valleystone Drive 7519 Tower+Co Cary, 9) 69-5 Office (919) 469-5559 Fax (919) 469-5530 PLANS PREPARED BY: vertical 2002 Production Drive r lutions Apex, 27539 Office: (888)8) 321-6167 Fax: (919) 321-1768 Simplicity Found TowerCo 5000 Valleystone Drive Cary, NC 27519 Phone: (919) 469-5539 FAX: (919) 469-5530 Job: MA2010 Project: ENG-15910 (123%) Client: TowerCo Drawn by: Kingsley App'd: Code: TIA-222-G Date: 06/11/12 Scale: NTS Path: L:\2012\1203_Steven's Estate_MA\Task 1\Models\TNX\ERP\MA2010-ERP.eri Dwg No. E-1 99.0 ft 89.5 ft 79.5 ft 69.5 ft 23.3 ft 0.0 ft REACTIONS - 100 mph WIND TORQUE 0 kip-ft 9 K SHEAR 618 kip-ft MOMENT 11 K AXIAL 40 mph WIND - 1.0000 in ICE 1 K SHEAR 108 kip-ft MOMENT 24 K AXIAL ARE FACTORED ALL REACTIONS S e c t i o n 1 2 3 4 5 6 7 8 L e n g t h ( f t ) 9. 5 0 0. 5 0 9. 5 0 0. 5 0 9. 5 0 0. 5 0 45 . 7 5 27 . 0 0 N u m b e r o f S i d e s 1 1 1 1 1 1 18 18 T h i c k n e s s ( i n ) 2. 0 0 0 0 2. 0 0 0 0 2. 5 0 0 0 2. 5 0 0 0 2. 7 5 0 0 2. 7 5 0 0 0. 1 8 7 5 0. 1 8 7 5 S o c k e t L e n g t h ( f t ) 3. 7 5 T o p D i a ( i n ) 4. 0 0 0 0 4. 0 0 0 0 5. 0 0 0 0 5. 0 0 0 0 5. 5 0 0 0 5. 5 0 0 0 19 . 2 5 0 0 24 . 9 8 5 2 B o t D i a ( i n ) 4. 0 0 0 0 5. 0 0 0 0 5. 0 0 0 0 5. 5 0 0 0 5. 5 0 0 0 19 . 2 5 0 0 25 . 9 0 5 7 28 . 7 5 0 0 G r a d e A5 7 2 - 5 0 A5 7 2 - 6 5 W e i g h t ( K ) 0. 4 0. 0 0. 6 0. 0 0. 8 0. 1 2. 1 1. 5 5. 5 25-ft x 15-ft Flag 99 RFS APXVSPP18-C-A20 (Sprint) 97 RFS APXVSPP18-C-A20 (Sprint) 97 RFS APXVSPP18-C-A20 (Sprint) 97 1900 RRH (65MHz) (Sprint) 97 1900 RRH (65MHz) (Sprint) 97 1900 RRH (65MHz) (Sprint) 97 800 RRH (Sprint) 97 800 RRH (Sprint) 97 800 RRH (Sprint) 97 External Notch Filter (Sprint) 97 External Notch Filter (Sprint) 97 External Notch Filter (Sprint) 97 (2) 1900 ACU-A20-N (Sprint) 97 (2) 1900 ACU-A20-N (Sprint) 97 (2) 1900 ACU-A20-N (Sprint) 97 800 ACU-A20-N (Sprint) 97 800 ACU-A20-N (Sprint) 97 800 ACU-A20-N (Sprint) 97 53"x10' Canister 94 CCI Twin Triple Band PCS TMA (ATT) 88 Kaelus Triplexer (ATT) 88 CCI Twin Triple Band PCS TMA (ATT) 88 KMW AM-X-CD-14-65-00T-RET (ATT) 88 KMW AM-X-CD-14-65-00T-RET (ATT) 88 CCI Twin Triple Band PCS TMA (ATT) 88 KMW AM-X-CD-14-65-00T-RET (ATT) 88 28"x10' Canister 84 DR65-19-00DPQ w/Mount Pipe (T-Mobile) 76 (2) LNA (T-Mobile) 76 DR65-19-00DPQ w/Mount Pipe (T-Mobile) 76 DR65-19-00DPQ w/Mount Pipe (T-Mobile) 76 (2) LNA (T-Mobile) 76 (2) LNA (T-Mobile) 76 20"x10' Canister 74DESIGNED APPURTENANCE LOADING TYPE TYPEELEVATION ELEVATION 25-ft x 15-ft Flag 99 RFS APXVSPP18-C-A20 (Sprint) 97 RFS APXVSPP18-C-A20 (Sprint) 97 RFS APXVSPP18-C-A20 (Sprint) 97 1900 RRH (65MHz) (Sprint) 97 1900 RRH (65MHz) (Sprint) 97 1900 RRH (65MHz) (Sprint) 97 800 RRH (Sprint) 97 800 RRH (Sprint) 97 800 RRH (Sprint) 97 External Notch Filter (Sprint) 97 External Notch Filter (Sprint) 97 External Notch Filter (Sprint) 97 (2) 1900 ACU-A20-N (Sprint) 97 (2) 1900 ACU-A20-N (Sprint) 97 (2) 1900 ACU-A20-N (Sprint) 97 800 ACU-A20-N (Sprint) 97 800 ACU-A20-N (Sprint) 97 800 ACU-A20-N (Sprint) 97 53"x10' Canister 94 CCI Twin Triple Band PCS TMA (ATT) 88 Kaelus Triplexer (ATT) 88 CCI Twin Triple Band PCS TMA (ATT) 88 KMW AM-X-CD-14-65-00T-RET (ATT) 88 KMW AM-X-CD-14-65-00T-RET (ATT) 88 CCI Twin Triple Band PCS TMA (ATT) 88 KMW AM-X-CD-14-65-00T-RET (ATT) 88 28"x10' Canister 84 DR65-19-00DPQ w/Mount Pipe (T-Mobile) 76 (2) LNA (T-Mobile) 76 DR65-19-00DPQ w/Mount Pipe (T-Mobile) 76 DR65-19-00DPQ w/Mount Pipe (T-Mobile) 76 (2) LNA (T-Mobile) 76 (2) LNA (T-Mobile) 76 20"x10' Canister 74 MATERIAL STRENGTH GRADE GRADEFy FyFu Fu A572-50 50 ksi 65 ksi A572-65 65 ksi 80 ksi TOWER DESIGN NOTES 1. Tower is located in Essex County, Massachusetts. 2. Tower designed for Exposure C to the TIA-222-G Standard. 3. Tower designed for a 100 mph basic wind in accordance with the TIA-222-G Standard. 4. Tower is also designed for a 40 mph basic wind with 1.00 in ice. Ice is considered to increase in thickness with height. 5. Deflections are based upon a 60 mph wind. 6. Tower Structure Class II. 7. Topographic Category 1 with Crest Height of 0.00 ft 8. TOWER RATING: 122.5% ttnnxxTToowweerr Job MA2010 Page 1 of 10 TowerCo 5000 Valleystone Drive Project ENG-15910 (123%) Date 15:13:30 06/11/12 Cary, NC 27519 Phone: (919) 469-5539 FAX: (919) 469-5530 Client TowerCo Designed by Kingsley  Tower Input Data There is a pole section. This tower is designed using the TIA-222-G standard. The following design criteria apply: Tower is located in Essex County, Massachusetts. Basic wind speed of 100 mph. Structure Class II. Exposure Category C. Topographic Category 1. Crest Height 0.00 ft. Nominal ice thickness of 1.0000 in. Ice thickness is considered to increase with height. Ice density of 56 pcf. A wind speed of 40 mph is used in combination with ice. Temperature drop of 50 °F. Deflections calculated using a wind speed of 60 mph. A non-linear (P-delta) analysis was used. Pressures are calculated at each section. Stress ratio used in pole design is 1. Local bending stresses due to climbing loads, feedline supports, and appurtenance mounts are not considered. Options Consider Moments - Legs Distribute Leg Loads As Uniform Treat Feedline Bundles As Cylinder Consider Moments - Horizontals Assume Legs Pinned Use ASCE 10 X-Brace Ly Rules Consider Moments - Diagonals √ Assume Rigid Index Plate √ Calculate Redundant Bracing Forces Use Moment Magnification √ Use Clear Spans For Wind Area Ignore Redundant Members in FEA √ Use Code Stress Ratios √ Use Clear Spans For KL/r SR Leg Bolts Resist Compression √ Use Code Safety Factors - Guys √ Retension Guys To Initial Tension √ All Leg Panels Have Same Allowable Escalate Ice √ Bypass Mast Stability Checks Offset Girt At Foundation Always Use Max Kz √ Use Azimuth Dish Coefficients Consider Feedline Torque Use Special Wind Profile √ Project Wind Area of Appurt. Include Angle Block Shear Check √ Include Bolts In Member Capacity √ Autocalc Torque Arm Areas Poles √ Leg Bolts Are At Top Of Section SR Members Have Cut Ends Include Shear-Torsion Interaction √ Secondary Horizontal Braces Leg Sort Capacity Reports By Component Always Use Sub-Critical Flow Use Diamond Inner Bracing (4 Sided) √ Triangulate Diamond Inner Bracing Use Top Mounted Sockets Add IBC .6D+W Combination Tapered Pole Section Geometry Section Elevation ft Section Length ft Splice Length ft Number of Sides Top Diameter in Bottom Diameter in Wall Thickness in Bend Radius in Pole Grade L1 99.00-89.50 9.50 0.00 Round 4.0000 4.0000 2.0000 A572-50 (50 ksi) L2 89.50-89.00 0.50 0.00 Round 4.0000 5.0000 2.0000 A572-50 (50 ksi) L3 89.00-79.50 9.50 0.00 Round 5.0000 5.0000 2.5000 A572-50 ttnnxxTToowweerr Job MA2010 Page 2 of 10 TowerCo 5000 Valleystone Drive Project ENG-15910 (123%) Date 15:13:30 06/11/12 Cary, NC 27519 Phone: (919) 469-5539 FAX: (919) 469-5530 Client TowerCo Designed by Kingsley Section Elevation ft Section Length ft Splice Length ft Number of Sides Top Diameter in Bottom Diameter in Wall Thickness in Bend Radius in Pole Grade (50 ksi) L4 79.50-79.00 0.50 0.00 Round 5.0000 5.5000 2.5000 A572-50 (50 ksi) L5 79.00-69.50 9.50 0.00 Round 5.5000 5.5000 2.7500 A572-50 (50 ksi) L6 69.50-69.00 0.50 0.00 Round 5.5000 19.2500 2.7500 A572-50 (50 ksi) L7 69.00-23.25 45.75 3.75 18 19.2500 25.9057 0.1875 0.3490 A572-65 (65 ksi) L8 23.25-0.00 27.00 18 24.9852 28.7500 0.1875 0.3490 A572-65 (65 ksi) Tapered Pole Properties Section Tip Dia. in Area in2 I in4 r in C in I/C in3 J in4 It/Q in2 w in w/t L1 4.0000 12.5664 6.2880 0.7080 2.0000 3.1440 12.5589 6.2794 0.0000 0 4.0000 12.5664 6.2880 0.7080 2.0000 3.1440 12.5589 6.2794 0.0000 0 L2 4.0000 12.5664 6.2880 0.7080 2.0000 3.1440 12.5589 6.2794 0.0000 0 5.0000 18.8496 21.2220 1.0620 2.5000 8.4888 42.3862 9.4192 0.0000 0 L3 5.0000 19.6350 15.3516 0.8850 2.5000 6.1406 30.6613 9.8116 0.0000 0 5.0000 19.6350 15.3516 0.8850 2.5000 6.1406 30.6613 9.8116 0.0000 0 L4 5.0000 19.6350 15.3516 0.8850 2.5000 6.1406 30.6613 9.8116 0.0000 0 5.5000 23.5619 26.5275 1.0620 2.7500 9.6464 52.9827 11.7739 0.0000 0 L5 5.5000 23.7583 22.4762 0.9735 2.7500 8.1732 44.8912 11.8721 0.0000 0 5.5000 23.7583 22.4762 0.9735 2.7500 8.1732 44.8912 11.8721 0.0000 0 L6 5.5000 23.7583 22.4762 0.9735 2.7500 8.1732 44.8912 11.8721 0.0000 0 19.2500 142.5498 4854.8641 5.8410 9.6250 504.4015 9696.5022 71.2323 0.0000 0 L7 19.5470 11.3446 520.8171 6.7672 9.7790 53.2587 1042.3195 5.6734 3.1992 17.062 26.3053 15.3055 1278.9906 9.1300 13.1601 97.1870 2559.6641 7.6542 4.3706 23.31 L8 25.9015 14.7577 1146.5085 8.8032 12.6925 90.3299 2294.5255 7.3803 4.2086 22.446 29.1935 16.9983 1752.0008 10.1397 14.6050 119.9590 3506.3069 8.5007 4.8712 25.98 Tower Elevation ft Gusset Area (per face) ft2 Gusset Thickness in Gusset GradeAdjust. Factor Af Adjust. Factor Ar Weight Mult. Double Angle Stitch Bolt Spacing Diagonals in Double Angle Stitch Bolt Spacing Horizontals in L1 99.00-89.50 1 1 1 L2 89.50-89.00 1 1 1 L3 89.00-79.50 1 1 1 L4 79.50-79.00 1 1 1 L5 79.00-69.50 1 1 1 L6 69.50-69.00 1 1 1 L7 69.00-23.25 1 1 1 L8 23.25-0.00 1 1 1 Feed Line/Linear Appurtenances - Entered As Area Description Face or Leg Allow Shield Component Type Placement ft Total Number CAAA ft2/ft Weight plf ttnnxxTToowweerr Job MA2010 Page 3 of 10 TowerCo 5000 Valleystone Drive Project ENG-15910 (123%) Date 15:13:30 06/11/12 Cary, NC 27519 Phone: (919) 469-5539 FAX: (919) 469-5530 Client TowerCo Designed by Kingsley Description Face or Leg Allow Shield Component Type Placement ft Total Number CAAA ft2/ft Weight plf LDF6-50A (1-1/4 FOAM) (Sprint) C No Inside Pole 97.00 - 0.00 3 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.66 0.66 0.66 *** VXL7-50 (1-5/8 FOAM) (AT&T) C No Inside Pole 88.00 - 0.00 6 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.75 0.75 0.75 *** LDF5-50A (7/8 FOAM) (T-Mobile) C No Inside Pole 76.00 - 0.00 6 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.33 0.33 0.33 Feed Line/Linear Appurtenances Section Areas Tower Section Tower Elevation ft Face AR ft2 AF ft2 CAAA In Face ft2 CAAA Out Face ft2 Weight K L1 99.00-89.50 A B C 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00 0.00 0.01 L2 89.50-89.00 A B C 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00 0.00 0.00 L3 89.00-79.50 A B C 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00 0.00 0.06 L4 79.50-79.00 A B C 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00 0.00 0.00 L5 79.00-69.50 A B C 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00 0.00 0.07 L6 69.50-69.00 A B C 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00 0.00 0.00 L7 69.00-23.25 A B C 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00 0.00 0.39 L8 23.25-0.00 A B C 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00 0.00 0.20 Feed Line/Linear Appurtenances Section Areas - With Ice Tower Section Tower Elevation ft Face or Leg Ice Thickness in AR ft2 AF ft2 CAAA In Face ft2 CAAA Out Face ft2 Weight K L1 99.00-89.50 A B C 2.221 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00 0.00 0.01 L2 89.50-89.00 A B C 2.209 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00 0.00 0.00 L3 89.00-79.50 A B 2.197 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00 0.00 ttnnxxTToowweerr Job MA2010 Page 4 of 10 TowerCo 5000 Valleystone Drive Project ENG-15910 (123%) Date 15:13:30 06/11/12 Cary, NC 27519 Phone: (919) 469-5539 FAX: (919) 469-5530 Client TowerCo Designed by Kingsley Tower Section Tower Elevation ft Face or Leg Ice Thickness in AR ft2 AF ft2 CAAA In Face ft2 CAAA Out Face ft2 Weight K C 0.000 0.000 0.000 0.000 0.06 L4 79.50-79.00 A B C 2.183 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00 0.00 0.00 L5 79.00-69.50 A B C 2.169 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00 0.00 0.07 L6 69.50-69.00 A B C 2.154 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00 0.00 0.00 L7 69.00-23.25 A B C 2.066 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00 0.00 0.39 L8 23.25-0.00 A B C 1.798 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00 0.00 0.20 Shielding Factor Ka Tower Section Feed Line Record No. Description Feed Line Segment Elev. Ka No Ice Ka Ice Discrete Tower Loads Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustment ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K *** KMW AM-X-CD-14-65-00T-RET (AT&T) A From Leg 1.00 0.00 0.00 0.0000 88.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.07 0.14 0.21 KMW AM-X-CD-14-65-00T-RET (AT&T) B From Leg 1.00 0.00 0.00 0.0000 88.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.07 0.14 0.21 KMW AM-X-CD-14-65-00T-RET (AT&T) C From Leg 1.00 0.00 0.00 0.0000 88.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.07 0.14 0.21 CCI Twin Triple Band PCS TMA (AT&T) A None 0.0000 88.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.03 CCI Twin Triple Band PCS TMA (AT&T) B None 0.0000 88.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.03 CCI Twin Triple Band PCS TMA (AT&T) C None 0.0000 88.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.03 Kaelus Triplexer (AT&T) C None 0.0000 88.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.03 0.00 0.00 *** ttnnxxTToowweerr Job MA2010 Page 5 of 10 TowerCo 5000 Valleystone Drive Project ENG-15910 (123%) Date 15:13:30 06/11/12 Cary, NC 27519 Phone: (919) 469-5539 FAX: (919) 469-5530 Client TowerCo Designed by Kingsley Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustment ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K DR65-19-00DPQ w/Mount Pipe (T-Mobile) A From Leg 1.00 0.00 0.00 0.0000 76.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.06 0.11 0.18 DR65-19-00DPQ w/Mount Pipe (T-Mobile) B From Leg 1.00 0.00 0.00 0.0000 76.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.06 0.11 0.18 DR65-19-00DPQ w/Mount Pipe (T-Mobile) C From Leg 1.00 0.00 0.00 0.0000 76.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.06 0.11 0.18 (2) LNA (T-Mobile) A None 0.0000 76.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.06 0.11 0.18 (2) LNA (T-Mobile) B None 0.0000 76.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.06 0.11 0.18 (2) LNA (T-Mobile) C None 0.0000 76.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.06 0.11 0.18 ************* 53''x10' Canister A None 0.0000 94.00 No Ice 1/2'' Ice 1'' Ice 23.06 23.56 24.06 23.06 23.56 24.06 0.53 0.50 0.67 28''x10' Canister A None 0.0000 84.00 No Ice 1/2'' Ice 1'' Ice 10.52 11.02 11.52 10.52 11.02 11.52 0.38 0.50 0.67 20''x10' Canister A None 0.0000 74.00 No Ice 1/2'' Ice 1'' Ice 6.84 7.34 7.84 6.84 7.34 6.84 0.33 0.50 0.67 ************* ************* *** RFS APXVSPP18-C-A20 (Sprint) A From Leg 1.00 0.00 0.00 0.0000 97.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.06 0.11 0.16 RFS APXVSPP18-C-A20 (Sprint) B From Leg 1.00 0.00 0.00 0.0000 97.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.06 0.11 0.16 RFS APXVSPP18-C-A20 (Sprint) C From Leg 1.00 0.00 0.00 0.0000 97.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.06 0.11 0.16 1900 RRH (65MHz) (Sprint) A None 0.0000 97.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.06 0.08 0.11 1900 RRH (65MHz) (Sprint) B None 0.0000 97.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.06 0.08 0.11 1900 RRH (65MHz) (Sprint) C None 0.0000 97.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.06 0.08 0.11 800 RRH (Sprint) A None 0.0000 97.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 0.02 800 RRH (Sprint) B None 0.0000 97.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 0.02 800 RRH (Sprint) C None 0.0000 97.00 No Ice 1/2'' Ice 0.00 0.00 0.00 0.00 0.01 0.01 ttnnxxTToowweerr Job MA2010 Page 6 of 10 TowerCo 5000 Valleystone Drive Project ENG-15910 (123%) Date 15:13:30 06/11/12 Cary, NC 27519 Phone: (919) 469-5539 FAX: (919) 469-5530 Client TowerCo Designed by Kingsley Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustment ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K 1'' Ice 0.00 0.00 0.02 External Notch Filter (Sprint) A None 0.0000 97.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.02 External Notch Filter (Sprint) B None 0.0000 97.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.02 External Notch Filter (Sprint) C None 0.0000 97.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.02 0.02 (2) 1900 ACU-A20-N (Sprint) A None 0.0000 97.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 (2) 1900 ACU-A20-N (Sprint) B None 0.0000 97.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 (2) 1900 ACU-A20-N (Sprint) C None 0.0000 97.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 800 ACU-A20-N (Sprint) A None 0.0000 97.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 800 ACU-A20-N (Sprint) B None 0.0000 97.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 800 ACU-A20-N (Sprint) C None 0.0000 97.00 No Ice 1/2'' Ice 1'' Ice 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 *** 25-ft x 15-ft Flag C None 0.0000 99.00 No Ice 1/2'' Ice 1'' Ice 38.76 38.76 38.76 38.76 38.76 38.76 0.10 0.15 0.20 Load Combinations Comb. No. Description 1 Dead Only 2 1.2 Dead+1.6 Wind 0 deg - No Ice 3 0.9 Dead+1.6 Wind 0 deg - No Ice 4 1.2 Dead+1.6 Wind 30 deg - No Ice 5 0.9 Dead+1.6 Wind 30 deg - No Ice 6 1.2 Dead+1.6 Wind 60 deg - No Ice 7 0.9 Dead+1.6 Wind 60 deg - No Ice 8 1.2 Dead+1.6 Wind 90 deg - No Ice 9 0.9 Dead+1.6 Wind 90 deg - No Ice 10 1.2 Dead+1.6 Wind 120 deg - No Ice 11 0.9 Dead+1.6 Wind 120 deg - No Ice 12 1.2 Dead+1.6 Wind 150 deg - No Ice 13 0.9 Dead+1.6 Wind 150 deg - No Ice 14 1.2 Dead+1.6 Wind 180 deg - No Ice ttnnxxTToowweerr Job MA2010 Page 7 of 10 TowerCo 5000 Valleystone Drive Project ENG-15910 (123%) Date 15:13:30 06/11/12 Cary, NC 27519 Phone: (919) 469-5539 FAX: (919) 469-5530 Client TowerCo Designed by Kingsley Comb. No. Description 15 0.9 Dead+1.6 Wind 180 deg - No Ice 16 1.2 Dead+1.6 Wind 210 deg - No Ice 17 0.9 Dead+1.6 Wind 210 deg - No Ice 18 1.2 Dead+1.6 Wind 240 deg - No Ice 19 0.9 Dead+1.6 Wind 240 deg - No Ice 20 1.2 Dead+1.6 Wind 270 deg - No Ice 21 0.9 Dead+1.6 Wind 270 deg - No Ice 22 1.2 Dead+1.6 Wind 300 deg - No Ice 23 0.9 Dead+1.6 Wind 300 deg - No Ice 24 1.2 Dead+1.6 Wind 330 deg - No Ice 25 0.9 Dead+1.6 Wind 330 deg - No Ice 26 1.2 Dead+1.0 Ice+1.0 Temp 27 1.2 Dead+1.0 Wind 0 deg+1.0 Ice+1.0 Temp 28 1.2 Dead+1.0 Wind 30 deg+1.0 Ice+1.0 Temp 29 1.2 Dead+1.0 Wind 60 deg+1.0 Ice+1.0 Temp 30 1.2 Dead+1.0 Wind 90 deg+1.0 Ice+1.0 Temp 31 1.2 Dead+1.0 Wind 120 deg+1.0 Ice+1.0 Temp 32 1.2 Dead+1.0 Wind 150 deg+1.0 Ice+1.0 Temp 33 1.2 Dead+1.0 Wind 180 deg+1.0 Ice+1.0 Temp 34 1.2 Dead+1.0 Wind 210 deg+1.0 Ice+1.0 Temp 35 1.2 Dead+1.0 Wind 240 deg+1.0 Ice+1.0 Temp 36 1.2 Dead+1.0 Wind 270 deg+1.0 Ice+1.0 Temp 37 1.2 Dead+1.0 Wind 300 deg+1.0 Ice+1.0 Temp 38 1.2 Dead+1.0 Wind 330 deg+1.0 Ice+1.0 Temp 39 Dead+Wind 0 deg - Service 40 Dead+Wind 30 deg - Service 41 Dead+Wind 60 deg - Service 42 Dead+Wind 90 deg - Service 43 Dead+Wind 120 deg - Service 44 Dead+Wind 150 deg - Service 45 Dead+Wind 180 deg - Service 46 Dead+Wind 210 deg - Service 47 Dead+Wind 240 deg - Service 48 Dead+Wind 270 deg - Service 49 Dead+Wind 300 deg - Service 50 Dead+Wind 330 deg - Service Maximum Tower Deflections - Service Wind Section No. Elevation ft Horz. Deflection in Gov. Load Comb. Tilt ° Twist ° L1 99 - 89.5 39.878 41 7.1528 0.0000 L2 89.5 - 89 26.396 41 6.0053 0.0000 L3 89 - 79.5 25.771 41 5.9619 0.0000 L4 79.5 - 79 15.615 41 3.9963 0.0000 L5 79 - 69.5 15.202 41 3.9088 0.0000 L6 69.5 - 69 9.823 41 1.2900 0.0000 L7 69 - 23.25 9.688 41 1.2892 0.0000 L8 27 - 0 1.579 41 0.5236 0.0000 Critical Deflections and Radius of Curvature - Service Wind ttnnxxTToowweerr Job MA2010 Page 8 of 10 TowerCo 5000 Valleystone Drive Project ENG-15910 (123%) Date 15:13:30 06/11/12 Cary, NC 27519 Phone: (919) 469-5539 FAX: (919) 469-5530 Client TowerCo Designed by Kingsley Elevation ft Appurtenance Gov. Load Comb. Deflection in Tilt ° Twist ° Radius of Curvature ft 99.00 25-ft x 15-ft Flag 41 39.878 7.1528 0.0000 461 97.00 RFS APXVSPP18-C-A20 41 36.887 6.8764 0.0000 461 94.00 53''x10' Canister 41 32.494 6.4829 0.0000 461 88.00 KMW AM-X-CD-14-65-00T-RET 41 24.543 5.8415 0.0000 342 84.00 28''x10' Canister 41 19.948 5.0116 0.0000 281 76.00 DR65-19-00DPQ w/Mount Pipe 41 12.970 3.0421 0.0000 228 74.00 20''x10' Canister 41 11.738 2.3141 0.0000 213 Maximum Tower Deflections - Design Wind Section No. Elevation ft Horz. Deflection in Gov. Load Comb. Tilt ° Twist ° L1 99 - 89.5 181.989 8 32.8183 0.0002 L2 89.5 - 89 122.808 8 27.8019 0.0001 L3 89 - 79.5 120.021 8 27.6094 0.0001 L4 79.5 - 79 74.078 2 18.7237 0.0001 L5 79 - 69.5 72.173 2 18.3226 0.0001 L6 69.5 - 69 47.079 6 6.1679 0.0000 L7 69 - 23.25 46.435 6 6.1641 0.0000 L8 27 - 0 7.605 6 2.5208 0.0000 Critical Deflections and Radius of Curvature - Design Wind Elevation ft Appurtenance Gov. Load Comb. Deflection in Tilt ° Twist ° Radius of Curvature ft 99.00 25-ft x 15-ft Flag 8 181.989 32.8183 0.0002 167 97.00 RFS APXVSPP18-C-A20 8 168.943 31.6139 0.0002 167 94.00 53''x10' Canister 8 149.731 29.8976 0.0002 167 88.00 KMW AM-X-CD-14-65-00T-RET 2 114.527 27.0717 0.0001 113 84.00 28''x10' Canister 2 93.840 23.3331 0.0001 83 76.00 DR65-19-00DPQ w/Mount Pipe 2 61.839 14.3130 0.0001 56 74.00 20''x10' Canister 2 56.089 10.9319 0.0000 50 Compression Checks Pole Design Data Section No. Elevation ft Size L ft Lu ft Kl/r A in2 Pu K Pn K Ratio Pu Pn L1 99 - 89.5 (1) TP4x4x2 9.50 0.00 0.0 12.5664 -4.25 565.49 0.008 L2 89.5 - 89 (2) TP5x4x2 0.50 0.00 0.0 12.5664 -0.06 565.49 0.000 L3 89 - 79.5 (3) TP5x5x2.5 9.50 0.00 0.0 19.6350 -1.85 883.57 0.002 L4 79.5 - 79 (4) TP5.5x5x2.5 0.50 0.00 0.0 19.6350 -1.93 883.57 0.002 ttnnxxTToowweerr Job MA2010 Page 9 of 10 TowerCo 5000 Valleystone Drive Project ENG-15910 (123%) Date 15:13:30 06/11/12 Cary, NC 27519 Phone: (919) 469-5539 FAX: (919) 469-5530 Client TowerCo Designed by Kingsley Section No. Elevation ft Size L ft Lu ft Kl/r A in2 Pu K Pn K Ratio Pu Pn L5 79 - 69.5 (5) TP5.5x5.5x2.75 9.50 0.00 0.0 23.7583 -4.89 1069.12 0.005 4.8.2 (1.22 CR) - 5 L6 69.5 - 69 (6) TP19.25x5.5x2.75 0.50 0.00 0.0 23.7583 -5.05 1069.12 0.005 4.8.2 (1.22 CR) - 6 L7 69 - 23.25 (7) TP25.9057x19.25x0.1875 45.75 0.00 0.0 14.9809 -8.04 1005.64 0.008 L8 23.25 - 0 (8) TP28.75x24.9852x0.1875 27.00 0.00 0.0 16.9983 -10.62 1083.81 0.010 Pole Bending Design Data Section No. Elevation ft Size Mux kip-ft Mnx kip-ft Ratio Mux Mnx Muy kip-ft Mny kip-ft Ratio Muy Mny L1 99 - 89.5 (1) TP4x4x2 5.80 40.00 0.145 0.00 40.00 0.000 L2 89.5 - 89 (2) TP5x4x2 27.67 40.00 0.692 0.00 40.00 0.000 L3 89 - 79.5 (3) TP5x5x2.5 73.52 78.13 0.941 0.00 78.13 0.000 L4 79.5 - 79 (4) TP5.5x5x2.5 73.47 78.13 0.940 0.00 78.13 0.000 L5 79 - 69.5 (5) TP5.5x5.5x2.75 126.86 103.98 1.220 0.00 103.98 0.000 L6 69.5 - 69 (6) TP19.25x5.5x2.75 126.70 103.98 1.218 0.00 103.98 0.000 L7 69 - 23.25 (7) TP25.9057x19.25x0.1875 399.94 520.76 0.768 0.00 520.76 0.000 L8 23.25 - 0 (8) TP28.75x24.9852x0.1875 618.48 637.38 0.970 0.00 637.38 0.000 Pole Shear Design Data Section No. Elevation ft Size Actual Vu K Vn K Ratio Vu Vn Actual Tu kip-ft Tn kip-ft Ratio Tu Tn L1 99 - 89.5 (1) TP4x4x2 0.83 282.74 0.003 0.00 23.55 0.000 L2 89.5 - 89 (2) TP5x4x2 4.27 424.12 0.010 0.00 23.55 0.000 L3 89 - 79.5 (3) TP5x5x2.5 5.15 441.79 0.012 0.00 45.99 0.000 L4 79.5 - 79 (4) TP5.5x5x2.5 5.27 530.14 0.010 0.00 45.99 0.000 L5 79 - 69.5 (5) TP5.5x5.5x2.75 5.40 534.56 0.010 0.00 61.22 0.000 L6 69.5 - 69 (6) TP19.25x5.5x2.75 5.35 3207.37 0.002 0.00 61.22 0.000 L7 69 - 23.25 (7) TP25.9057x19.25x0.1875 7.52 502.82 0.015 0.00 1042.80 0.000 L8 23.25 - 0 (8) TP28.75x24.9852x0.1875 8.64 541.90 0.016 0.00 1276.32 0.000 Pole Interaction Design Data Section No. Elevation ft Ratio Pu Pn Ratio Mux Mnx Ratio Muy Mny Ratio Vu Vn Ratio Tu Tn Comb. Stress Ratio Allow. Stress Ratio Criteria L1 99 - 89.5 (1) 0.008 0.145 0.000 0.003 0.000 0.153 1.000 4.8.2 L2 89.5 - 89 (2) 0.000 0.692 0.000 0.010 0.000 0.692 1.000 4.8.2 L3 89 - 79.5 (3) 0.002 0.941 0.000 0.012 0.000 0.943 1.000 4.8.2 ttnnxxTToowweerr Job MA2010 Page 10 of 10 TowerCo 5000 Valleystone Drive Project ENG-15910 (123%) Date 15:13:30 06/11/12 Cary, NC 27519 Phone: (919) 469-5539 FAX: (919) 469-5530 Client TowerCo Designed by Kingsley Section No. Elevation ft Ratio Pu Pn Ratio Mux Mnx Ratio Muy Mny Ratio Vu Vn Ratio Tu Tn Comb. Stress Ratio Allow. Stress Ratio Criteria L4 79.5 - 79 (4) 0.002 0.940 0.000 0.010 0.000 0.943 1.000 4.8.2 L5 79 - 69.5 (5) 0.005 1.220 0.000 0.010 0.000 1.225 1.000 4.8.2 L6 69.5 - 69 (6) 0.005 1.218 0.000 0.002 0.000 1.223 1.000 4.8.2 L7 69 - 23.25 (7) 0.008 0.768 0.000 0.015 0.000 0.776 1.000 4.8.2 L8 23.25 - 0 (8) 0.010 0.970 0.000 0.016 0.000 0.980 1.000 4.8.2 Section Capacity Table Section No. Elevation ft Component Type Size Critical Element P K øPallow K % Capacity Pass Fail L1 99 - 89.5 Pole TP4x4x2 1 -4.25 565.49 69.4 Pass L2 89.5 - 89 Pole TP5x4x2 2 0.07 565.49 69.3 Pass L3 89 - 79.5 Pole TP5x5x2.5 3 -1.85 883.57 94.3 Pass L4 79.5 - 79 Pole TP5.5x5x2.5 4 -1.93 883.57 94.3 Pass L5 79 - 69.5 Pole TP5.5x5.5x2.75 5 -4.89 1069.12 122.5 Fail L6 69.5 - 69 Pole TP19.25x5.5x2.75 6 -5.05 1069.12 122.3 Fail L7 69 - 23.25 Pole TP25.9057x19.25x0.1875 7 -8.04 1005.64 77.6 Pass L8 23.25 - 0 Pole TP28.75x24.9852x0.1875 8 -10.62 1083.81 98.0 Pass Summary Pole (L5) 122.5 Fail RATING = 122.5 Fail  Program Version 6.0.0.8 - 9/7/2011 File:L:/2012/1203_Steven's Estate_MA/Task 1/Models/TNX/ERP/MA2010-ERP.eri 1'-Fi :4/4" BASE PLATE AND ANCHOR ROD CONFIGURATION PLAN SCALE: 1 1/2" = 1'-0" PROJECT INFORMATION: STEVEN'S ESTATE SITE M MA2010 723 OSGOOD STREET NORTH ANDOVER, MA 01845 (ESSEX COUNTY) DRAWN BY: KCI CHECKED BY: JHW SHEET NUMBER: REVISION: 0 BPL V51 #: 1 2 1203 PLANS PREPARED FOR: -� 5000 Valleystone Drive 7519 7 Tower+Co Cary, 9) 69-5 Office (919) 469-5559 Fax (919) 469-5530 PLANS PREPARED BY: vBrtiCal 2002 Production Drive V vt?f L!? I�C?S Apex, NC 27539 Office: (888) 321-6167 Fax: (919) 321-1768 0 06- 11- 12 TowerCo, LLC. REV DATE: Issued For: DRAWN BY: KCI CHECKED BY: JHW SHEET NUMBER: REVISION: 0 BPL V51 #: 1 2 1203 PLANS PREPARED FOR: -� 5000 Valleystone Drive 7519 7 Tower+Co Cary, 9) 69-5 Office (919) 469-5559 Fax (919) 469-5530 PLANS PREPARED BY: vBrtiCal 2002 Production Drive V vt?f L!? I�C?S Apex, NC 27539 Office: (888) 321-6167 Fax: (919) 321-1768 VSi Job No.: 121203 Date: 6/11/2012 Calculated by: KCI ANCHOR ROD DESIGN, DEFORMATION METHOD, TIA-222-G Input -Mu 618kipft= factored moment reaction at top of base plate Vut 9kip= factored shear reaction at top of base plate η 0.50= coefficient per Figure 4.4 Fub 100ksi= specified minimum tensile stength of bolt b eff 18.75in= tributary width of base plate t1.75in= thickness of flange plate Fy 60ksi= yield stress of flange plate ϕ 0.8 Q 2 2 0   d 11261 2 0 0   inA 3.25 3.25 0   in2ϕRnt ϕ FubA() ϕRnt 260 260 0   kip Vutn Vut η Vun Vutn Q() Vu Vun Vun 0    Rnt = nominal tension strengthsumQAdQd2A sumQAd2225in4 ---------------------------------d = distance from center Pu M u dA()  sumQAdA = area of fastener Q = quantity of fasteners r Pu Vu ϕRnt    [section 4.9.9] CONSTANTS: psi lb in2 ksi1000psi kip1000lbPu 200.4 0.0 0.0   kipVu 4.5 4.5 0   kipr 79 2 0   % --------------------------------------------------------------------------------------------------- Anchor Rods_TIA-222-G.xmcdPage 1 of 4 m 4 1 8 0 0   inMPL Q 2  Pum     MPL 68.9 0.0 0.0   kipftM PL826.8kipin fb MPL 1.5b eff t2 6   fb 57.594ksi F'b 0.9Fy rb fb F'b  rb 107% --------------------------------- Anchor Rods_TIA-222-G.xmcdPage 1 of 4 5 5/16'1 FLANGE PLATE AND FLANGE BOLT CONFIGURATION PLAN AT 69 -FT SCALE: 3" = V-0" PROJECT INFORMATION: STEVEN'S ESTATE SITE M MA2010 723 OSGOOD STREET NORTH ANDOVER, MA 01845 (ESSEX COUNTY) DRAWN BY: KCI CHECKED BY: JHW 5HEET NUMBER: REV15ION: 0 FPL V51 #: 1 2 1203 PLANS PREPARED FOR: 5000 Valleystone Drive T Wer+Co Cary, NC 27519 Office (919) 469-5559 Fax (919) 469-5530 PLANS PREPARED BY: vBrtiCal 2002 Production Drive V urt?f L1 tl�C?S Apex, NC 27539 Office: (888) 321-6167 Fax: (919) 321-1768 0 06- 11- 12 TowerCo, LLC. REV DATE: Issued For: DRAWN BY: KCI CHECKED BY: JHW 5HEET NUMBER: REV15ION: 0 FPL V51 #: 1 2 1203 PLANS PREPARED FOR: 5000 Valleystone Drive T Wer+Co Cary, NC 27519 Office (919) 469-5559 Fax (919) 469-5530 PLANS PREPARED BY: vBrtiCal 2002 Production Drive V urt?f L1 tl�C?S Apex, NC 27539 Office: (888) 321-6167 Fax: (919) 321-1768 VSi Job No.: 121203 Date: 06/11/2012 Calculated by: KCI FLANGE PLATE DESIGN, DEFORMATION METHOD, TIA-222-G Input -Mu 126.70kipft= factored moment reaction at top of base plate Vut 5.35kip= factored shear reaction at top of base plate Fub 120ksi= specified minimum tensile stength of bolt b eff 5.3125in= effective width of bending plane t1.5in= thickness of base plate Fy 60ksi= specified minimum yield stength of base plate ϕ 0.75 Q 2 4 4 2   d 8 6 15 16 4 0   inAn 0.606 0.606 0.606 0.606   in2Ag 0.785 0.785 0.785 0.785   in2ϕRnt ϕ FubAgϕRnt 70.65 70.65 70.65 70.65   kip ϕRnv 0.45ϕ FubAnϕRnv 24.543 24.543 24.543 24.543   kip Vun Vut Q()  Vu Vun Vun Vun Vun    Rnt = nominal tension strength sumQAdQd2A d = distance from center --------------------------------- A = area of fastener sumQAd596000Cm 2s 1in4Pu M u dA()  sumQAdQ = quantity of fasteners r Pu ϕRnt    [section 4.9.6.1]rc Pu ϕRnt   2 Vu ϕRnv   2     [section 4.9.6.4] CONSTANTS: psi lb in2 ksi1000psiPu 31.6 27.4 15.8 0.0   kipVu 0.4 0.4 0.4 0.4   kipr 45 39 22 0   %rc 20 15 5 0   % kip1000lb ------------------------------------------------------------------------------------------------------------------------------------ Flange Bolts_TIA-222-G.xmcdPage 1 of 4 m 1 7 16 0 0 0   inMPL Q 2  Pum      MPL 45.5 0.0 0.0 0.0   kipinM PL45.5kipin ϕMn 0.91.5 b eff t2 6FyϕMn 161.4kipin --------------------------------- rb M PL ϕMn rb 28% --------------------------------- Flange Bolts_TIA-222-G.xmcdPage 1 of 4 Vertical Solutions Inc.Page 1/1 CAISSON Version 4.91 3:11:02 PM Monday, June 11, 2012 Vertical Solutions Inc. ********************************************************************************* * * * PIER FOUNDATIONS ANALYSIS AND DESIGN - (C) 1995,2002 POWER LINE SYSTEMS, INC.* * * ********************************************************************************* *** ANALYSIS IDENTIFICATION : MA2010 NOTES : *** PIER PROPERTIES CONCRETE STRENGTH (ksi) = 4.00 STEEL STRENGTH (ksi) = 60.00 DIAMETER (ft) = 5.000 DISTANCE FROM TOP OF PIER TO GROUND LEVEL (ft) = 1.00 *** SOIL PROPERTIES LAYER TYPE THICKNESS DEPTH AT TOP OF LAYER DENSITY CU KP PHI (ft) (ft) (pcf) (psf) (degrees) 1 S 20.00 0.00 115.0 3.000 30.00 2 S 17.00 20.00 115.0 3.000 30.00 *** DESIGN (FACTORED) LOADS AT TOP OF PIER MOMENT (ft-k) = 618.0 VERTICAL (k) = 11.0 SHEAR (k) = 9.0 ADDITIONAL SAFETY FACTOR AGAINST SOIL FAILURE = 1.33 *** CALCULATED PIER LENGTH (ft) = 13.500 *** CHECK OF SOILS PROPERTIES AND ULTIMATE RESISTING FORCES ALONG PIER TYPE TOP OF LAYER BELOW TOP OF PIER THICKNESS DENSITY CU KP FORCE ARM (ft) (ft) (pcf) (psf) (k) (ft) S 1.00 8.98 115.0 3.000 208.53 6.98 S 9.98 3.52 115.0 3.000 -195.76 11.83 *** SHEAR AND MOMENTS ALONG PIER WITH THE ADDITIONAL SAFETY FACTOR WITHOUT ADDITIONAL SAFETY FACTOR DISTANCE BELOW TOP OF PIER (ft) SHEAR (k) MOMENT (ft-k) SHEAR (k) MOMENT (ft-k) 0.00 12.8 860.3 9.6 646.8 1.35 12.5 877.5 9.4 659.8 2.70 5.3 890.5 4.0 669.6 4.05 -11.3 887.5 -8.5 667.3 5.40 -37.3 855.8 -28.1 643.4 6.75 -72.8 782.5 -54.7 588.3 8.10 -117.7 655.0 -88.5 492.5 9.45 -172.0 460.6 -129.3 346.3 10.80 -155.8 218.8 -117.1 164.5 12.15 -82.6 56.8 -62.1 42.7 13.50 0.0 0.0 0.0 0.0 *** TOTAL REINFORCEMENT PCT = 0.40 REINFORCEMENT AREA (in^2) = 11.31 *** USABLE AXIAL CAP. (k) = 11.0 USABLE MOMENT CAP. (ft-k) = 1256.7 *** US Standard Re-Bars (Select one of the following): 57 BARS #4 (AREA = 0.20 in^2 DIA = 0.500 in) AT SPACING (in) = 2.76 37 BARS #5 (AREA = 0.31 in^2 DIA = 0.625 in) AT SPACING (in) = 4.25 26 BARS #6 (AREA = 0.44 in^2 DIA = 0.750 in) AT SPACING (in) = 6.04 19 BARS #7 (AREA = 0.60 in^2 DIA = 0.875 in) AT SPACING (in) = 8.27 15 BARS #8 (AREA = 0.79 in^2 DIA = 1.000 in) AT SPACING (in) = 10.47 12 BARS #9 (AREA = 1.00 in^2 DIA = 1.128 in) AT SPACING (in) = 13.09 9 BARS #10 (AREA = 1.27 in^2 DIA = 1.270 in) AT SPACING (in) = 17.45 8 BARS #11 (AREA = 1.56 in^2 DIA = 1.410 in) AT SPACING (in) = 19.63 6 BARS #14 (AREA = 2.25 in^2 DIA = 1.693 in) AT SPACING (in) = 26.18 *** WEIGHT OF CAISSON (kips) = 39.761 *** PRESSURE UNDER CAISSON DUE TO INPUT DESIGN AXIAL LOAD (psf) = 560.2