Loading...
HomeMy WebLinkAbout2012-11-20 Planning Board Supplemental Materials (20) DEFINITIVE SUBDIVISION PLAN LEGEND. LIST OF WAIVERS REQUESTED: " �� EX. CONTOUR 1) SECTION VI - ROADWAY CONSTRUCTION TURKEY HILL 2) SECTION 5.7.3. - PROJECT REVIEW FEES LOCATED IN DECIDUOUS TREE (> 6" DIA.) 3) SECTION 6.8.1, TABLE 1A - MIN. ROW WIDTH 50' TO 40' N. AND 0 VER, MASSACHUSETTS 0 SEWER MANHOLE (ESSEX COUNTY) CB F-1CA TCHBA SIN 34A BIT. BITUMINOUS PREPARED FOR 33A TARA LEIGH DEVELOPMENT CONC. CONCRETE du 31A 32A B.v.w. SCALE: 1 "= 20' DATE: OCTOBER 1, 2012 EOP EDGE OF PAVEMENT 35A BVW BORDERING VEGETATED WETLAND PREPARED BY 30A ' 00-0 A-11 �, WETLAND FLAG NUMBER/LOCATION SULLIVAN ENGINEERING GROUP, LLC - ' 22 MOUNT VERNON ROAD 29A BOXFORD, MA 01921 w RESERVED FOR REGISTRY USE ONLY (978) 352-7871 SHEET 2 OF 2 WETLAND 28A ENVIRONMENTAL ANIOAUGUST NORSEON BY 2012 RECORD OWNER: j li, LOT LA YO UT/SITE DEVELOPMENT I TLD,ELL OR'S MAP 96 PARCEL 4 - 115 CARTER FIELD ROAD NORTH ANDOVER / 00e _ NORTH ANDOVER, MA 01845 27A F. I - DEED BOOK 13045, PAGE No. 176 PLANNING BOARD All OF APPROVED UNDER THE SUBDIVISION 4�,��"� L / ho %��JG - I 36A ZONING: CONTROL LAW UPON CONDITIONS $ ZONING DISTRICT.- R2 o H MIN. LOT AREA: 43,560 S.F. ° 13572 MIN. LOT FRONTAGE: 150 FEET - - - - - - - - - - - - - - - TAX MAP 96 PARCEL 2 MIN. LOT WIDTH: 100 FEET f L t!► 4 26A N/F EDWARD + ANN STEVENS " ` MIN. CBA: 757 - - - - - - - - - - - - - - - / ,SB/EPLP FND - - - - - - - - - - - - - - - r:10F S _/ \ I CERTIFY THAT THIS PLAN r" 25A / r I \ HAS BEEN PREPARED IN tV ((402.24')) - - ACCORDANCE WITH THE RULES - - - - - - - - - - - - - - - 0 CiVtL � 'Sp W \ �i�, S80°37 NOU Lbs — 16" \ I AND REGULATIONS OF THE DATE:- - - - - - - - - - - - - �'QG1S1tR� a`� 24A - REGISTERS OF DEEDS. SSk1NAlE�6. s TH-1 \ � •— � / Prop. 500 Gallon Drywell 112.32 - w/60" Crushed Stone, SBNDEPLP �'`� / 23A ��/ ' surrounding. \6� I _ GRAPHIC SCALE S FJ� •ISIO Idle/ � 61.2' � - - � 20 0 10 20 / 22A-1 oo, LOT 2 50,480 S.F.± -"- - - - - - - I ( IN FEET ) i - (45,999 S.F.± Upland) `� 1 inch = 20 ft. C.B.A. = 1007. ` rC) y��/�` TOTAL LOT DISTURBANCE: Entire Roofed Arearrl - � � m �� ��� DRIVEWAY: 5,920 S.F. to be hardpiped to Porous r �, X �� �O Drywell D � / / HOUSE: 1,800 S.F. / — — — z v oN / YARD: 7,500 S.F. / PROP. DWELLING Pavement I z U) � � S.F.f � 0 21A TOTAL: '15,220 S.F. 3,200 rri Ln CIO PW I _ C? / / / ` -PSSILT FENCING TO BE \\ —�-- \ \ INSTALLED ALONG 100' p ali, BVW BUFFER LINE v 20A S80°S 0"W / \ / _ PRIOR TO ANY SITE _ I / \ WORK. m - / 120.00 _ / NPROP. E—ONE I \ GRINDER PUMP PROP. 1" TYPE K 373 30.9 \ COPPER WATER 19A SERVICE (PW) I � I PROP. 1 1/4" SDR 21 -PVC TREELINE I \ \ I 1 / I SEWER FORCE MAIN (4' COVER MIN.) I - I l S6 —80� ali, � I \8 _ I \ LOT B - - L_188.50 - I RECENTLY SUBDIVIDED & APPROVED ANR I - BUILDING LOT OWNED BY TLD, LLC I " 28„M - � 17A 1 3' HIGH°FENCE REVISIONS - EX. GARDEN AREA / ° 1 10/22/12 ADD DRAINAGE JDS JDS 1` 28"M ` %� ° o NO. DATE DESCRIPTION BY CHK'D z `n / \ PROP. DRIVEWAY CONSTRUCTION 4 I o -P,� _ TO MATCH EXISTING SITE GRADING O Q FFER, SLOPE (SEE SITE PLAN) (NO PROPOSED GRADING CHANGES) o g��RgC��Rg 4" OF POROUS ASPHALT (POLYMER MODIFIED PERFORMANCE GRADE ASPHALT BINDER (PGAB) / / I \v / ,I \\ \ \ - ` 5`A° 5 4” OF 3/4" CRUSHED STONE �/ GARDENING o II ( I \ \ °mss 12" OF BANK RUN GRAVEL SHED 3" OF 3/8" PEA GRAVEL Lz1111 \ ` \\ ` i _ / SILT FENCING TO BE 4" OF 3/4" CRUSHED STONE I I I _I / — — — \ \ ° / INSTALLED ALONG 100' EXISTING SUBGRADE MATERIAL °p ° BVW BUFFER LINE I I I \ � \ �j (ALL EXISTING TOPSOIL & SUBSOIL TO BE REMOVED) I I I I 20 'p� S ��5 PRIOR TO ANY SITE\ 7 WORK. DRI VEWA Y CONSTRUCTION o CROSS SECTION I i I i I — o- \ � •o NOT TO SCALE STONE RET. WALL NOTE ON DRIVEWAY SUBBASE CONSTRUCTION: I I I � 8 f \ \ � i BVW BOFFER THE DRIVEWAY SUBBASE SHALL BE INSTALLED WITH I I I 1100 A TWO INCH OVERFILL AT THE OUTSET OF CONSTRUCTION. I I I I I \ THE OVERFILL WILL THEN BE REMOVED PRIOR ONCE THE SITE 3�" I ` 12 (TO BE REMOVED) \ IS STABILIZED AND PRIOR TO PAVING. THE SUBBASE SHALL / I BE INSPECTED BY THE DESIGN ENGINEER FOR COMPACTION R=25.00' \ AND INFILTRATIVE CAPACITY AND, IF NECESSARY, SCARIFIED TOI II I LOT 1 = 55,249 S.F.± THE DEPTH REQUIRED PRIOR TO PLACEMENT OF THE POROUS L=37.80' ASPHALT LAYER. (557249 S.F.— Upland) z N rn � I I I PROP. 1" TYPE K �° D 1 C.B.A. = 100 COPPER WATER I 1 p X 1) NO SAND OR SALT SHALL BE APPLIED TO THE POROUSI I I 0 / SERVICE (PW) 0 z O Z_ PAVEMENT AREAS DURING THE WINTER MONTHS. I I / L � 2) PAVEMENT SHALL BE INSPECTED AS REQUIRED TO INSURE STRUCTURAL I I I 1 I I I r-- L D �o INTEGRITY AND FUNCTIONALITY. I I 1 I - 1 I / O 3) IF THE POROUS PAVEMENT BECOMES CLOGGED WITH SILT, SAND, OR OTHER I I I I 1 I I / PROP. 1 1/4" SDR 21 PVC N 4T D O MATERIALS THE PAVEMENT SHALL BE VACUUM CLEANED. I I I I I / r— SEWER FORCE MAIN (4' COVER MIN.) I 0 11 m z � 4) THE OWNER OF THE SITE SHALL EDUCATE THE CONTRACTOR RESPONSIBLE I I 1 II I 1 I 1J +� Mon FOR SNOW/ICE REMOVAL WHERE THE POROUS PAVEMENT AREAS ARE ON—SITE I 1 I 1 I I I -- � I U1 n O r AND THAT SAND/SALT SHALL NOT BE USED IN THESE AREAS. I I i I Imo\\ W T m p W J• � 5) THE DRIVEWAY SHALL UNDERGO VACUUMING AS REQUIRED TO PREVENT CLOGGING. I I I I EX. 1 STORY STRUCTURE ���\ 31.1' 6) SEALCOATING THE DRIVEWAY SURFACE IS STRICTLY PROHIBITED. I 1 I � I I sod � 0 7) THE DRYWELL AND PAVEMENT AREAS SHALL BE MAINTAINED PER PLAN. I 1 I 1 I ai 3 CAR GqR / °I♦ Q OPERATION &• MAINTENANCE — POROUS PAVEMENT' II I II Ilz 1- 11 I \ Q . SOILS INFORMA TION: II II 1 �' �' 11 I §1I 1 � rn TEST PITS WERE PERFORMED BY I I CP v'_ I I I / \ JOHN D. SULLIVAN ///, P.E., C.S.E. I II 1 I I I I 1 24" 24 \ ON 8/29/12 TEST PIT: TH-1 I I I ELEV.= 68.6'-4- 1 I I I I `- �t Cn G.W. OBSERVED AT NONE � I II I I 1 IJ O � 0"-8" HORIZON A LS 10 YR 3/3 w aD I 1 1 \ 8"-16" HORIZON B LS 10 YR 6/8 C° \ 16"-70" LAYER C.• LS 2.5 Y 5/4 0 1 cQo BIT. CONC. 1 8"( DRIVEWAY It SOIL MOTTLING 0 49" \ E.S.H.G.W. @ OR BELOW ELEV = 64.5' I I _ \ PROP. 12'W POROUS PAVEMENT FILTER FABRIC MIRAFI 140N PERCOLATION RATE : 10 MPI SHELF 20"-38" I 1 I DRIVEWAY TO MEANDER TO TO ENCLOSE TOP & SIDEWALL AREAS I 1 \ ' \\ MINIMIZE DISTURBANCE TO ESTABLISHED VEGETATION. 3" ° n TOP ELEV=70.17' I 1 - \ � / 6 TDP I I \ — — — — — PROP. 1 1/4" SDR 21 PVC ° ° ° a SEWER FORCE MAIN (4' COVER MIN.) ill 60" 0 u 4" DIA INLET \ TR II I II I = INV ELEV=69.5' fFCINE ° ao 60" III- 00 � 03 o 1 cgs ° @ CO I=1 \ 2'-0' - - ITI' S H EA _ - - 28" 0 O OVO 0 III- IIII � I I II \\ \� \ \ \ \ 94, PROP. SEWER MANHOLE =1 a _ \ \9 PROP. 4" SDR 35 PVC =1 I 12» DRAIN HOLES 4 T❑ 1,5 TAPERED II I II �• ?� N86°49 09 E S 1 203.50 SEWER SERVICE S=0.02' \11 40.47 L I— BOTTOM OF STONE 243.97' ELEV=66.5' \ EOP � I I SB/EPLP 3/4" TO 1 1/2" SECTION VIEW EOP FND� WASHED STONE / EX. SEWER MAIN S 2' MIN. S ITEM NO, WEIGHT �� BENCHMARK: 500 GALLON DW-SDW STANDARD 5,142# SEASONAL HIGHSEWER PW GROUNDWATER ELEV <= 64.5' GREAT (ASSUMED DATUM POND ROAD PRECAST CONCRETE DRYWELL - 500 GALLON (SHALLOW) o .� EX. WATER MAIN NOT TO SCALE