Loading...
HomeMy WebLinkAboutMiscellaneous - 800 JOHNSON STREET 5/30/2018 R'11 North Andover Health Department Community and Economic Development Division ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES LOCATION INFORMATION ADDRESS: 800 Johnson St MAP: 38 LOT: 106 INSTALLER: Tim Quinlan DESIGNER: Jack Sullivan PLAN DATE: 6/21/17 Final Rev: 5/7/18, last revision date May 2, 2018 BOH APPROVAL DATE ON PLAN: 5/2/18 INSPECTIONS TANK INSPECTION: DATE OF BED BOTTOM INSPECTION:5/1/2018 — Michele Grant DATE OF FINAL CONSTRUCTION INSPECTION: 5/11/18 DATE OF FINAL GRADE INSPECTION: SITE CONDITIONS ® Contractor reports any changes to design plan N/A Existing septic tank properly abandoned ® Internal plumbing all to,one building sewer ® Topography not appreciably altered Comments: SEPTIC TANK ® Building sewer in continuous grade, on compacted firm base ❑ Cleanouts per plan ® Bottom of tank hole has 6" stone base ® Weep hole plugged ® 1500 gallon tank has been installed H-20 loading ® Monolithic tank construction t ® Water tightness of tank has been achieved by visual testing ® Inlet tee installed, centered under access port M V-'J Outlet tee installed, centered under access port (effluent filter) Z 24" inch cover to finish grade installed over outlet access port Z Hydraulic cement around inlet & outlet Comments: DISTRIBUTION-BOX Z Installed on stable stone base Z H-20 D-Box N/A Inlet tee (if pumped or >0.08'/foot) M Hydraulic cement around inlet & outlets Z Observed even distribution Z Speed levelers provided (not required) Z Schedule 40 PVC Pipe Comments: SOIL ABSORPTION SYSTEM (General) Z Bottom of SAS excavated down to C soil layer, as provided on plan Z Size of SAS excavated as per plan Z Title 5 sand installed, if specified on plan Z 40 Mil HDPE barrier installed Z Laterals installed and ends connected to header (and vented if impervious material above) Z Elevations of laterals and chambers installed as on approved plan N/A Retaining wall (boulder/ concrete /timber/ block) ❑ Final cover as per plan Comments: Large boulders will be installed on the sides of the leach field adjacent to the limit of work line and property line per the installer. This should be checked during the final grade inspection FINAL GRADE Loamed Seeded Cover per plan Comments: DOCUMENTS NEEDED Certification of Installation Form submitted By engineer and signed and dated by Engineer and installer As-Built Plan BM = 96.40 HR = 7.96 HI = 104.36 SYSTEM ELEVATIONS ROD AS-BLT INVERT DESIGN INVERT ELEVATION ELEV ELEV Benchmark Buildinr Sewer OUT 4.58 99.43 99.26 Se tic Tank IN 4.92 99.09 98.96 -------------- Septic Tank OUT 5.20 98.81 98.71 -------------- ..........- Distribution Box IN 5.54 98.47 98.48 Distribution Box OUT 5.71 98.30 98,31 Lateral 1 TOP 5.76 / 5.98--__ Lateral 1 INVERT 98.25 / 98.03 98.15 98.00 Lateral 2 TOP 5.82 / 6.00 Lateral 2 INVERT 98.19 / 98.01 98.15 98.00 Lateral 3 TOP 5.81 Lateral 3 INVERT 98.20 / 98.00 98.15 98.00 Lateral 4 TOP 5.82 / 6.00 Lateral 4 INVERT 98.19 / WOO 98.15 98.00 Bottom of Bed 6.86 97.50 97.50 ----------- CRITICAL SETBACK DISTANCES Mark those distances checked in the field against the design plan and regulatory setback Tank SAS Sewer Property line 10 10 Cellar wall 10 20 Inground pool 10 20 Slab foundation 10 10 Deck, on footings, etc 5 10 -- Waterline 40 10 101 Private drinking well 75 1002 50 Irrigation well 75 100 Surface Water 25 50 Bordering Vegetated Wetland Salt Marsh, Inland/Coastal Bank' 75 100 Wetlands bordering surface water supply or Crib. (in Watershed) 150 150 Trib. to surface water supply 325 325 Public well 400 400 Interim Wellhead Prot. Area Reservoirs 400 400 Drains (wat. supply/trib.) 50 100 Drains (intercept g.w.) 25 50 Drains (Other) Foundation 10(5) 20(10) Drywells 20 25 Suction line 222(2) 100 feet is a minimum acceptable distance and no variance is allowed for a lesser distance(NA 5.02). As defined in 310 CMR 10.55, 10.32, 10.54, and 10,30,respectively,pursuant to 15.211(3), also by NA wetland bylaws