Loading...
HomeMy WebLinkAboutTitle V Inspection Report - 145 FOREST STREET 6/5/2018 Commonwealth of Massachusetts Title 5 Official Inspection Form R . . ........ Subsurface Sewage Disposal System Form Not for Voluntary Assessments sv 145 Forest Street Property Address Dennis O'Sullivan 0 f :ration is Owner's Name r ired for every North Andover MA 01845 5-18-2018 pa Cityrrown State Zip Code Date of Inspection Inspection results must be submitted on this form. Inspection forms may not be altered in any way. Please see completeness checklist at the end of the form. Impiortant:When A. General Information t)� fiii�i ig out forms ("M , "Mv, oh the computer, Us ,' .only the tab 1 Inspector: 's\ kq�' r�o move your cu sor-do not Neil James Bateson us�the return Name of Inspector k' Bateson Enterprises Inc. Company Name 7 111 ArgIlla Road Company Address Andover MA 01810 City/Town State Zip Code 978-475-4786SI-15 Telephone Number License Number B. Certification I certify that I have personally inspected the sewage disposal system at this address and that the information reported below is true, accurate and complete as of the time of the inspection. The inspection was performed based on my training and experience in the proper function and maintenance of on site sewage disposal systems. I am a DEP approved system inspector pursuant to Section 15.340 of Title 5 (310 CMR 15.000).The system: Passes ❑ Conditionally Passes E] Fails F-1 ee Furth r Evaluation by the Local Approving Authority 5-18-2018 Inset r r Signature � Date The system inspector shall submit a copy of this inspection report to the Approving Authority(Board of Health or DEP)within 30 days of completing this inspection. If the system has a design flow of 10,000 gpd or greater, the inspector and the system owner shall submit the report to the appropriate regional office of the DER The original should be sent to the system owner and copies sent to the buyer, if applicable, and the approving authority. ""This report only describes conditions at the time of inspection and under the conditions of use at that time.This inspection does not address how the system will perform in the future under the same or different conditions of use. I [ s.doc-rev.6116 Title 5 Official Inspection Form Subsurface sewage Disposal Systern•Page 1 of 17 r Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form Not for Voluntary Assessments 145 Forest Street Property Address Dennis O'Sullivan wrier O �j 1, wners Name I I,)rmation is North Andover MA 01845 5-18-2018 r (1dired for every City/Town State Zip Code Date of Inspection B. Certification (cont.) Inspection Summary: Check A,B,C,D or E always complete all of Section D A) System Passes: I have not found any information which indicates that any of the failure criteria described in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below. Comments: After permit from B.O.H. install new outlet tee in septic tank& new d-box, septic system now passes Title 5 Inspection. ----------------- 13) System Conditionally Passes: F-1 one or more system components as described in the "Conditional Pass"section need to be replaced or repaired. The system, upon completion of the replacement or repair, as approved by the Board of Health, will pass. Check the box for"yes", no" or"not determined" (Y, N, ND)for the following statements. If"not determined," please explain. The septic tank is metal and over 20 years old*or the septic tank(whether metal or not) is structurally H unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass inspection if the existing tank is replaced with a complying septic tank as approved by the Board of Health. If A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of Compliance indicating that the tank is less than 20 years old is available. El Y n N F1 ND (Explain below): ---------- __--- ------------------------- ,5 ns doe-rev.6116 Title 5 official Inspection Form:Subsurface Sewage Disposal System-Page 2 of 17