HomeMy WebLinkAbout- Title V Inspection Report - 230 GRAY STREET 8/28/2018 Commonwealth of Massachusetts Y= -- Title 5 Official Inspection Form RECEIVED Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 230 Gray Street_ ..__... ... ..._._.._.. _.... __...._..._,. .._ .0 N��N �i� i NANDOVER c _ Property Address i.NN� IU'AR C7l Nt Dat Le OwnerOwner's Name .__.,... . __ _._. .__....._........ information is required for every North Andover MA 01845 8-15-2018 ..-..- _ -- .. .,.,,_.._..._ m ........... .. _.—. page. Cltyrrown State Zip Code Date of Inspection Inspection results must be submitted on this form. Inspection forms may not be altered in any way. Please see completeness checklist at the end of the form. filling out forms A, Inspector Information filling out forms on the computer, use only the tab Nell James Bateson key to move your Name of Inspector cursor-do not Bateson Enterprises Inc. use the return __..__.. .... ..._ .-.__-__ _ _..._..._.._. key. Company Name 111 Argilla Road rQ Company Address Andover MA 01810 City/Town State Zip Code reg 978 4754786S1 15 Telephone Number — _.... License Number ........._..... _ B. Certification I certify that: I am a DEP approved system inspector in full compliance with Section 15.340 of Title 5 (310 CMR 15.000), 1 have personally inspected the sewage disposal system at the property address listed above; the information reported below is true, accurate and complete as of the time of my inspection; and the inspection was performed based on my training and experience in the proper function and maintenance of on-site sewage disposal systems.After conducting this inspection I have determined that the system: 1. ® Passes 2. ❑ Conditionally Passes 3. ❑ Needs Further Evaluation by the Local Approving Authority 4. ❑ Fails 8-15-2018 Inspect 's ig tura Date The system inspector shall submit a copy of this inspection report to the Approving Authority (Board of Health or DEP)within 30 days of completing this inspection. If the system has a design flow of 10,000 gpd or greater, the inspector and the system owner shall submit the report to the appropriate regional office of the DEP. The original form should be sent to the system owner and copies sent to the buyer, if applicable, and the approving authority. Please note: This report only describes conditions at the time of inspection and under the conditions of use at that time.This inspection does not address how the system will perform in the future under the same or different conditions of use. t5insp.doc•rev.7/2612018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 1 of 18 4^uCommonwealth of Massachusetts �� =�"���N�� 0� �����N N����0���"������� ����N�0�� ' � ��@�� �� ��oN00��0��N Inspection N-��mmm � ' - Subsurface Sewage Dhsposm| SymtwmmForn - NotkxVb|unbaryAsaeaennont 230 Gray Street Property Address Dat Le Owner Owner'mName information is required for every North Andover MA 01845 8-15-2018 page. �� � Zip Code Date of Inspection C. Inspection �%�00mary Inspection Summary: Complete 1. 2. 3' nr5and all of4and 8. 1) System Passes: I have not found any information which indicates that any of the failure criteria described in 310 CMR 15.3O3orin31DCMR 15.304 exist. Any failure criteria not evaluated are indicated below. Comments: After removing trees around d-box. septic system now passes Title 5 Inspection. 2\ System Conditionally Passes: El One or more system components as described in the "Conditional Pass" section need to be replaced or repaired. The system, upon completion of the replacement or repair, as approved by the Board of Health, will pass. Check the box for"yes", "no"or"not determined" (Y, N, ND)for the following statements. If"not determined," please explain. The septic tank is metal and over 20 years old* or the septic tank(whether metal or not) is structurally unaoumd, exhibits substantial infiltration orexfi(tnadon nrtank failure is imminent. System will peso inspection |fthe existing tank is replaced with a complying septic tank as approved by the Board of Health. * A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of Compliance indicating that the tank isless than 20years old ieavailable. �� Y N ND (Explain be|ow):