HomeMy WebLinkAbout- Correspondence - 2198 TURNPIKE STREET 9/6/2018 (9) JM ASSOCIATES Land Planning-Civil Engineering-Surveying 325 Main St. North Reading, Ma. 01864 Tel. 978-664-6668 Fax 978-664-8155 www.jmassociateseng.com August 1, 2017 Brian LaGrasse Director North Andover Health Dept. 120 Main St. North Andover, Ma 01845 Re: 2198 Turnpike St. Subsurface Sewage Disposal System Plan (Map 108C Lot 6) Dear Mr. LaGrasse In response to the comments noted in your letter of July 20, 2017 we are submitting revised plans dated August 2, 2017. We have addressed your comments as follows: 1. A Local Upgrade Approval request is required for only test pit within the proposed disposal system area (3 10 CMR 15.404(1)(10. I have enclosed the L UA request, 1 A Title 5 variance request is required to have no percolation test within the proposed disposal system area (3.10 CMR 15.104(4)), I have enclosed the variance request 3. A note or chart is required to be on the design plan listing all variances and Local Upgrade Approvals (NA 3.2). A note has been added to the design plan 4. Please submit the Local Upgrade Approval request form 9A with the revised plan. The LUA request is enclosed 5. On sheet I oft, the site plan view does not depict the proposed finish grading as shown on the profile view. Also make sure the proposed finish grading meets the breakout requirement for all trenches. The current existing grading does not meet the breakout reciuirement for trenches#I and42. I have added finish grading to the site plan. Also I have re-evaluated the elevation oj'seasonal high ground water beneath the proposed trenches. Iplotted a seasonal high ground water elevation line between test pits 6 and 7. This plot resulted in the revised seasonal high water elevations shown on sheet 2. These revised elevations allowed me to lower the system by 0.78 fEet and as a result the system is no longer a mounded system. 6. Indicate on the design plan any Natural Heritage & Endangered Species Program mapped areas (INA 3.2). Mass GIS maps indicate an area in close proximity to the proposed disposal system. The Natural Heritage and Endangered Species Line has been added to the plan. 7. Since the Infiltrator Chamber system is proposed as an alternative soil absorption system the "Standard Conditions for Alternative Soil Absorption Systems with General Use Certification and/or Approved for Remedial Use"will apply. Please provide the following as required by the approval conditions Section HO 8): - proof that the Designer has satisfactorily completed any required training by the CompanYjbr the design and inswIlation of the Technology; No specific training is required by the dcsigner for the design of this lechnoloD - Certification by the Designer that the design conforms to the Approval, any Company Design Guidance, and 310 CMR, 15,000; and A note hay been added to the design plan a certification, signed by the Owner of record for the propertv to be served by the Technology, stating that the property Owner: 1. has been provided a copy of the Title 5 11A technology y Approval, the Owner's Manual, and the Operation and Maintenance Manual, and the Own,-,j, (-jai-pp.v to Pnnin1v with all for and rondifinne., A certification by the owner is enclosed 2. for Systems installed under a Remedial Tse Approval, the owner agrees to fulfill his responsibilities to provide a Deed Notice as required by 310 CMR 15.287(10) and the Approval,- -1- for Systems installed under a Remedial Use Approval, the owner agrees to fulfill his responsibilities to provide written notification oj'the Approval to any new Oivner, as required by 310 CMR 15.287(5).- Items 2 and 3 above are specifical1v waived by the Infiltrator approval letter