Loading...
HomeMy WebLinkAbout- Correspondence - 2198 TURNPIKE STREET 9/6/2018 (11) C bob � r 1 North Andover Health Department Community and Economic Development Division July 20, 2017 John F. McQuilkin, Jr., P.E. JM Associates 325 Main Street North Reading, MA. 01864 Re: Subsurface Sewage Disposal System Plan for 2198 Turnpike Street(Map 1080,I,ot 6) Dear Mr. McQui:lki.n: The proposed wastewater system design plan for the above site dated June 20, 2017 and received on June 27, 2017 has been reviewed. Unfortunately,the plan cannot be approved until the following items are corrected. The specific section in"Title 5: 3.10 CMR 15.000, or North Andover regulation that is not met by this design follows each item where applicable. I. A Local Upgrade Approval request is required for only test pit within the proposed disposal system area(3 10 CMR 15.404(1)(k), 2. A Title 5 variance request is required to have no percolation test within the proposed disposal system area(3 10 CMR 15.1.04(4)), 3. A note or chart is required to be on the design plan listing all variances and Local Upgrade Approvals (NA 3.2), 4. Please submit the Local Upgrade Approval request form 9A with the revised plan. 5. On sheet 1 of 2, the site plan view does not depict the proposed finish grading as shown on the profile view. Also make sure the proposed finish grading meets the breakout requirement for all trenches. The current existing grading does not meet the breakout requirement for trenches#I and#2. 6. Indicate on.the design plan any Natural Heritage&Endangered Species Program mapped areas (NA 3.2). Mass GIS maps indicate an area in close proximity to the proposed disposal system. 7. Since the Infiltrator Chamber system is proposed as an alternative soil absorption system the"Standard Conditions for Alternative Soil Absorption Systems with General Use Certification and/or Approved for Remedial Use"will apply. Please provide the following as required by the approval conditions Section 1I(18): I Page 1 of 2 North.Andover Health Department, Town Hall, 120 Main Street, North Andover, MA 01.845 Phone: 978,688.9540 Fax: 978,688. 9542 - Proof that the Designer has satisfactorily completed any required training by the Company for the design and installation of the Technology; - certification by the Designer that the design conforms to the Approval, ally Company Design Guidance, and 310 CMR 15.000; and - a certcation, signed by the Owner of'recordfor the property to be served by the Technology, stating that the property Owner: 1. has been provided a copy of the Title 511A technology Approval, the Owners Manual, and the Operation and Maintenance Manual, and the Owner agrees to comply with all terms and conditions,- 2. for Systems installed under a Remedial Use ApI.)roval, the owner agrees tofiffill his responsibilities to provide a Deed Notice as required by 310 CMR 15.28 7(10) and the Approval,- 3. for Systems installed under a Remedial Use Approval, the owner agrees tofiffl1l his responsibilities to provide written notification of the Approval to any new Owner, as required by 310 CMR 15.287(5); 4. if the design does not provide for the use of garbage grinders, the restriction is understood and accepted; and 5. whether or not covered by a warranty, the System Owner understands the requirement to repair, replace, modify or take any other action as required by the Department or the LAA, if the Department or the LAA determines the System to be failing to protect public health and safety and the environment, as defined in 310 CMR 15.303. 8. In accordance with Section 11(7) of"Standard Conditions for Alternative Soil Absorption Systems with General Use Certification and/or Approved for Remedial Use",please provide a best feasible upgrade plan. Please feel free to contact the office or Mill River Consulting at 978-282-0014 with any questions you may have. We look forward to working with you to obtain a wastewater treatment and dispersal system which will be in compliance with all regulations and assure protection of public health and the environment of North Andover. Since y, urian J..... aGrasse, CEHT Director of Public Health cc: Jorge Solano File Page 2 of 2 North Andover I-lealth Department, Town 11all, 120 Main Street, North Andover, MA 01845 Phone: 978.688.9540 Fax: 978.688,9542