Loading...
HomeMy WebLinkAbout- Consultant Review - 312 BOXFORD STREET 11/14/2018 North Andover Health Department Community and Economic Development Division ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES LOCATION INFORMATION ADDRESS: 312 Boxford Street MAP: 104.B LOT: 59 INSTALLER: Dean Dynan DESIGNER: Jack Sullivan – Sullivan Engineering Group PLAN DATE: final revision July 23, 2018 received on July 26, 2018 BOH APPROVAL DATE ON PLAN: Aug 20, 2018 INSPECTIONS TANK INSPECTION: 10/18/18 DATE OF BED BOTTOM INSPECTION: 9/12/2018 DATE OF FINAL CONSTRUCTION INSPECTION: 10/18/18 DATE OF FINAL GRADE INSPECTION: SITE CONDITIONS Contractor reports any changes to design plan Existing septic tank properly abandoned Internal plumbing all to one building sewer Topography not appreciably altered Comments: 9/28/2018 3 pits crushed and filled – Brian LaGrasse SEPTIC TANK Building sewer in continuous grade, on compacted firm base Cleanouts per plan Bottom of tank hole has 6” stone base Weep hole plugged 1500 gallon tank has been installed H-10 loading Monolithic tank construction Water tightness of tank has been achieved by visual testing Inlet tee installed, centered under access port Outlet tee installed, centered under access port (gas baffle/effluent filter) _____ inch cover to within 6” of finish grade installed over one access port Hydraulic cement around inlet & outlet Comments: Building sewer (under deck) was piped through existing tank (also under deck) and connected to new tank. Filter installed in outlet. DISTRIBUTION-BOX Installed on stable stone base H-20 D-Box Inlet tee (if pumped or >0.08’/foot) Hydraulic cement around inlet & outlets Observed even distribution Speed levelers provided (not required) Schedule 40 PVC Pipe Comments: SOIL ABSORPTION SYSTEM (General) Bottom of SAS excavated down to C soil layer, as provided on plan Size of SAS excavated as per plan Title 5 sand installed, if specified on plan 40 Mil HDPE barrier installed Laterals installed and ends connected to header (and vented if impervious material above) Elevations of laterals and chambers installed as on approved plan Retaining wall (boulder / concrete / timber/ block) Final cover as per plan Comments: FINAL GRADE Loamed Seeded Cover per plan Comments: DOCUMENTS NEEDED Certification of Installation Form submitted By engineer and signed and dated by Engineer and installer As-Built Plan BM = ______ HR = ______ HI = ______ SYSTEM ELEVATIONS ROD AS-BLT INVERT DESIGN INVERT ELEVATION ELEV ELEV Benchmark 105.77 Building Sewer OUT Septic Tank IN 4.0 Septic Tank OUT 4.2 Pump Chamber IN Pump Chamber OUT Distribution Box IN 7.78 Distribution Box OUT 7.92 Lateral 1 TOP Lateral 1 INVERT 7.95 Lateral 2 TOP Lateral 2 INVERT 7.95 Lateral 3 TOP Lateral 3 INVERT 7.96 Lateral 4 TOP Lateral 4 INVERT Lateral 5 TOP Lateral 5 INVERT Lateral 6 TOP Lateral 6 INVERT Top of Chamber Bottom of Bed/Chamber