HomeMy WebLinkAbout- Correspondence - 50 FARNUM STREET 12/17/2018 CHRISTIANSEN & SERGI
CMS A DIVISION OFTI-IE MORIN CAMERON GROUP
PROFESSIONAL ENGINEERS AND LAND SURVEYORS
1�30,':�UMMLF',,SfRH.:I, HAVERHILL, MAO t8130
10 '&WW C's�engf corn fa x 9 8 2 3
December 11, 2018
Mr. Brian LaGrasse
Director of Public Health
North Andover Health Dept.
120 Main Street
North Andover, MA 01845
Re: Septic System Design Plan for 50 Famum Street
(Map 107.A Parcel 087)
Dear Mr. LaGrasse:
It is our opinion that the covered porch does not have a cellar or crawl space and is not a slab
foundation and therefore does not need to meet the setbacks set forth in 310 CMR 15.211. The raised
covered porch does rest on CMU blocks around a portion of the perimeter, however the area below the
porch is not completely enclosed. The building sewer runs underground beneath the covered porch. As
such, the offsets to the septic tank and leach field should be from the foundation wall where the building
sewer exists the actual foundation as shown on the approved plan.
Very truly yours,
4 C ri ti nsen &Sergi, Inc.
P.E.-Stephen awyer, P
ao
5
(W,'
12l111�. 8 "Town of North Andover Mail-Re:50 Farnum
o AN0,0VER
Massacl�rasgt Michele Grant<mgrant@northandoverma.gov> t
�ardm 1
I
Ike: 50 Farnum J
1 message
Brian LaGrasse <blagrasse@northandoverma.gov> Tue, Dec 11, 2018 at 11:32 AM
To: "T.J. Melvin" <TJ@csi-engr.com>
Cc: Michele Grant<mgrant@northandoverma.gov>
Thanks the plan is sufficient but we need you to please submit an explanation of the structure located 5.5'from the septic
tank. The design plan depicts this as a covered porch but the pictures of the tank excavation submitted by the installer
clearly show this as a cinder block foundation with a crawl space or more which includes a window beneath the covered
porch. Please submit an originally signed and stamped letter stating that this setback distance of 5.5' meets Title 5
criteria without a variance and we will issue the COC.
On Tue, Dec 11, 2018 at 11:14 AM T.J. Melvin <TJ@csi-engr*.com>wrote:
Michelle,
I have attached a PDF of the revised plan. Can you take a quick look and make sure everything looks good? If so, we
will print copies, stamp and deliver. Thanks.
TJ Melvin, P.E.
Christions'en & Sergi
f
A Division of The Morin-Cameron Group, Inc.
160 Summer Street, Haverhill, MA 01830
HAVERHILL, MA DANVERS, MA
Christiansen & Sergi, A,Division of The Merin-Garneron Group, Inc. The Morin- arneron Group, Inc.
160 Surnmer Street, Haverhill, MA 01830 66 Elm Street, Danvers, MA 01923
P:978-373-0310 P:978-777-8586
www.csi-engr.com F: 978-774-3488
i
www rnorincarneron.corn
I
This communication, including attachments, is for the exclusive use of the addressee and may contain proprietary, confidential andlor privileged
information. If you are not the intended recipient, any use, copying, disclosure, dissemination or distribution is strictly prohibited. If you are not the
intended recipient;please notify the sender immediately by return e-mail,delete this communication and destroy all copies.
i
1
https://mail.google.com/mail/u/0?ik=d4458df3d9&view=pt&search=all&permthid=thread-f%3A1619572667061411395%7Cmsg-f°/o3A16195738023799... 112
12/11/2018, lawn of North Andover Mail-Re:50 Farnum
i
Brian J. LaGrasse, CHHT
Director of Public Health 1
Town of North Andover j
120 Main Street
North Andover, MA 01845
Phone 978.688.9540
Fax 978.688.8476
Email blagrasse@northarrdoverma.gov
Web www.northandoverma.gov
https://mail.google.corn/mail/u/0?ik=d4458df3d9&view=pt&search=al I&permthid=thread-f°/a3Al 619572667061411395°/a7Cmsg-f%3A l 6l 95738023799... 2/2
1213/2018 IMG-2953.JPG
/
u�
I
1
l
6�.
I I
https://rnail.google.com/mail/u/O/#inboxlWhctKJVBGjCTbtbjDdQSNztMkStxMkZiSCIDSlbtcCdWGWScpXFjPndsVgTWsxVbCTnFbPQ?projector=l&m... 1l1
CS
A D I IEION(") THE MORINCA ERON GROI.W
PROFESSIONAL AL NGI EEC AND LAND a RVE'YOR
37",- 'k(: )
I
November 6, 2018
Mr. Brian LaGrasse
Director of Public Health .
North Andover Health Dept.
120 Main Street
North Andover, MA 01845
Re: Septic System Design Plan for 50 Famum Street
(Map 107.A Parcel 087)
Dear Mr. LaGrasse:
We have received your November 5, 2018 comments on the above referenced plan, and we offer the
following response.
1. A benchmark was added to the plan.
2. The approximate location of the existing system has been added to the plan. Note 24 has been
added to Sheet 1 regarding the abandonment of the system.
3. A riser with a manhole cover to grade has been shown on the Profile View on Sheet 2.
4. Note 23 on Sheet 1 has been added regarding the annual maintenance of the effluent filter.
5. All elevations have been provided in the soil evaluation results.
6, The side section view of the D-Box on Sheet 2 has been revised to a 9 outlet D-Box. The Shea
Concrete Item Number has been revised to B-9DBH.
trust that these responses fully address all of your comments.
Please contact me if you have any questions.
i
Very truly yours,
Christiansen & Sergi, Inc.
Stephen Sawyer, P.E.
11/5/2018 Town of North Andover Mail-50 Farnum Street initial plan review
r
N0 A OVE
Massaelauk Toni Wolfenden <tolfenden@northandoverma.gov>
50 Farnum Street initial plan review
1 message
Dan Ottenheimer<dano@millriverconsulting.com> Fri, Nov 2, 2018 at 12:10 PM
To: Brian LaGrasse<blagrasse@northandoverma.gov>, Michele Grant<mgrant@northandoverma.gov>, Toni Wolfenden
<tolfenden@north andoverma.gov>
Cc: Pam Lally<plally@miliriverconsulting.com>
Brian, Michele, Toni -
Attached please find our initial disapproval letter for the septic system design at 50 Farnum Street.
You will note that the date of the letter is in red and would need to be adjusted for when you send this out, plus I did not
have handy the date of their submission so would kindly ask you to fill that item in (also shown in red) as well.
Any questions, please do let me know.
Best,
Dan
i
Daniel Ottenheimer
President
ILL RIVER CONSULTING
G
(.rekl9ivc 8ohltiolta For I.and Duva!testara ent
https://mai I.google.comlmail/u1017ui=2&ik=a0c6f4e4cf&jsver=IV1 D3NcG5d0.en.&cbl=g mail_fe_181028.01_p2&view=pt&cat=Mill°1o20River&search=cat... 1/2
11/5/2018 Town of North Andover Mail-50 Farnum Street initial plan review
'6 Sargent Street
Gloucester, MA 01930-2719
Phone: 978-282-0014 ext.802
www.millriverconsulting.corrt
Member: New England Water Environment Association, Yankee Onsite Wastewater Association, Massachusetts
Environmental Health Association,
t� 50 Farnum Street Review Letter vl.doe