HomeMy WebLinkAbout- Correspondence - 61 FOREST STREET 3/27/2019 %1/ii Zo North Andover Health Department Community and Economic Development Division March 8, 2019 Jack Sullivan, P.E. Sullivan Engineering Group, L.L.C. P.O. Box 2004 Woburn, MA 01888 Re: 61 Forest Street(Maps 106A, Lot 168) Dear Mr. Sullivan: The proposed wastewater system design plans for the above site dated February 19, 2019. and received on March 4, 2019 has been reviewed. Unfortunately, the plan cannot be approved until the following items are corrected. The specific section in Title 5: 310 CMR 15.000, or North Andover(NA 0.0), or MA DEP Standard Conditions for Alternative Soil Absorption Systems with General Use Certification and/or Approved Remedial Use (SCASAS II.X)regulation that is not met by this design follows each item where applicable. Sheet 1 of 2: 1. On proposed site plan, indicate the name of abutters from recent tax map (NA 3.2a.). 2. On proposed site plan, indicate the name of the record applicant, or if owner and applicant, state as such(NA 3.2g.). 3. On proposed site plan, if appropriate, add the note: I certify the locations, elevations and ties shown on this plan result from an actual survey made on the ground. Signature of Designer, Date (NA 3.2s.) 4. On proposed site plan, indicate the location and information about the additional test hole where refusal was encountered and was deemed not usable (CMR 15.220 (4)(h)). 5. Provide a minimum of two deep observation hole tests in the presence of the Approving Authority, or request a local upgrade Approval or variance(CMR 15.102 (2)). 6. On proposed site plan, existing grade at the center of TH-1 appears to be 97.5. The SOIL DATA ofDTH-1 says the grade is 98.3. Clarify the discrepancy. (CMR 15.220 (4)(h)). 7. On proposed site plan, existing grade at the center of TH-2 appears to be 90.5. The SOIL DATA of DTH-2 says the grade is 89.9. Clarify the discrepancy. (CMR 15.220 (4)(h)). Pagel of 3 North Andover Health Department, Town.Hall, 120 Main Street, North Andover, MA 01845 Phone: 978.688.9540 Fax: 978.688.9542 8. On proposed site plan and SYSTEM PROFILE detail (Sheet 2 of 2), show location of proposed contour 102 to ensure the top of septic tank grading is per regulation(CMR 15.228 (1)). 9. On proposed site plan, indicate surface drainage shall be directed away from the soil absorption system (CMR 15.240 (11)). Sheet 2 of 2: 1. On System Profile detail, change the groundwater elevation from 89.3 to 89.4. Confirm the graphic elevations of other related septic system components to ensure: "The minimum vertical separation distance between the bottom of the...soil absorption system above the high ground-water elevation shall be four feet..." or request a Local Upgrade Approval or variance. (CMR 15.212 (1)(a)). 2. On System Profile detail, confirm the graphic elevations of the proposed top and bottom of the distribution box, the proposed top (breakout) and bottom and inlets of the infiltration chambers, and the top and bottom of the proposed polybarrier. Adjust their locations on the profile. 3. On System Profile detail, change the note: INSPECTION PORT TO GRADE to read: INSPECTION PORT TO WITHIN 3 INCHES OF FINISHED GRADE to conform to the same note on TYPICAL H 10 INSPECTION PORT DETAIL and the proposed site plan on Sheet I of 2. 4. On System Profile detail, specify all components of system and model/brands for the proposed outlet Tee filter(NA 3.2n.). 5. On Septic Tank detail, delete the words: "NOTE 5", its leader arrow and associated graphics. 6. On Septic Tank detail, PLAN VIEW shows a baffle wall located inside the tank, but SECTION VIEW does not show a wall. Indicate if the wall is included or not. 7. On Septic Tank detail, at the end of NOTES: 2., add the words: "...AND NORTH ANDOVER BoH REGULATIONS (CURRENT EDITIONS).". 8. On D-Box (13 Outlet)by Shea Concrete Products detail, at the end of NOTES: 2., add the words: "...AND NORTH ANDOVER BoH REGULATIONS (CURRENT EDITIONS).". 9. On TYPICAL H 10 INSPECTION PORT DETAIL, delete the two notes: 6" SCH 40 PVC OR SDR-35 PVC PIPE RISER and 6"PVC END CAP, END PLUG OR CLEANOUT W/IN 3" OF FINISHED GRADE and insert the note: 4"PVC OR SDR-35 PVC PERFORATED PIPE W/SCREW TYPE CAP W/IN 3" OF FINISHED GRADE. (CMR 15.240(13) and SCASAS 11. 17.)). 10. If applicable, add the note: I certify the design conforms to the Approval, any Company Design Guidance, and 310 CMR 15.000. Signature of Designer, Date (SCASAS 11. 18. c.)). In addition: 1. Provide a draft or signed version of the certification that is to be signed by the Owner of record for the property to be served by the Technology, stating that the property Owner: a.) has been provided a copy of the Title 5 I/A technology approval, the Owner's Manual, and the Operation and Maintenance Manual, and the Owner agrees to comply with all Page 2 of 3 North.Andover Health Department, Town Hall, 120 Main Street, North Andover, MA 01845 'hone: 978.688.9540 Fax: 978,688,9542 terms and conditions; b)the design does not provide for the use of garbage grinders and the restriction is understood and accepted; and c.)whether or not covered by a warranty, the System Owner understands the requirement to repair, replace,modify or take any other action as required by the Department or the LAA, if the Department or the LAA determines the System to be failing to protect public health and safety and the environment, as defined in 310 CMR 15.303 (SCASAS 11. 18. d) i., iii., iv.)). 2. Provide the current MA DEP issued Approval Letter with the design plan when a proprietary system or device is proposed(NA 3.3). 3. In the various details, clarify the end locations and limits of the filter fabric covering the chambers. 4. On proposed site plan, 12 equal rows of 4-foot long chambers are proposed. The distance between the distribution box and two middle rows appears to be two feet. Consider the constructability of this arrangement. Please feel flee to contact the office or Mill River Consulting at 978-282-0014 with any questions you may have. We look forward to working with you to obtain a wastewater treatment and dispersal system which will be in compliance with all regulations and assure protection of public health and the environment of North Andover. Sin-cf"prely, /rian J. LaGrasse, CENT Director of Public Health cc: Scott Cooke File Page 3 of 3 North Andover Health Department, Town Hall, 1.20 Main Street, North Andover, MA 01845 Phone: 978.688.9540 Fax: 978.688.9542