HomeMy WebLinkAboutREScheck Compliance Certificate REScheck Software i . Compliance Certificate Project Proposed New Residence - Lot 3, 303 Abbott Street Energy Code: 2009 1ECC Location: North Andover, Massachusetts Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 2,533 ft2 Glazing Area 11% Climate Zone: 5 Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 303 Abbott Street, Lot 3 Chris Poravas North Andover, MA Poravas Design &Consulting 49 Appleton Street Melrose, MA 02176 339-927-1579 pdcdesignl@gmail.com Compliance: 1.1%Better Than Code Maximum UA: 368 Your UA: 364 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Floor 1: All-Wood joist/Truss:Over Unconditioned Space 1,107 30.0 0.0 0.033 37 Floor 2: All-Wood jo I st/Truss:Over Unconditioned Space 365 30.0 0.0 0.033 12 Floor 3:All-Wood joist/Truss:Over Outside Air 13 30.0 0.0 0.033 0 Ceiling 1: Flat Ceiling or Scissor Truss 1,335 38.0 0.0 0.030 40 Ceiling 3: Cathedral Ceiling 150 30.0 0.0 0.034 5 Wall 1: Wood Frame, 16" o.c. 2,863 21.0 0.0 0.057 142 Window 1: Wood Frame:Double Pane with Low-E 307 0.290 89 Door 1: Solid 33 0.500 17 Door 2: Solid 36 0.600 22 Compliance Statement: The proposed building design described her y9 EDA t uilding plans, specifications, and other calculations submitted with the permit application.The proposed bu 4M. It to meet the 2009 IECC requirements in REScheck Version 4.5.0 and to comply with the mandatory require r�Es i ed in the `k Inspection Checklist. 0.505 / Name-Title Sign MASS. �� Date c2�F�CTM OF MP����� Project Title: Proposed New Residence - Lot 3, 303 Abbott Street Report date: 11/24/1 Data filename: C:\01-Projects\Residential\Corcoran-North Andover\10-Energy Audits\Abbott- Lot 3.rck Page 1 of 9 Project Title: Proposed New Residence- Lot 3, 303 Abbott Street Report date: 11/24/1 Data filename: C:\01-Projects\Residential\Corcoran-North Andover\10-Energy Audits\Abbott- Lot 3.rck Page 2 of 9 ����� �� � Version � � � �uv��� ����Y��� ��U�� �"�= = �� _="��� � � � � �� Checklist�� � N����N�����= Q������ ���������� � ���0= � Energy Code: 2009 IECC Requirements: 0.0Y6 were addressed directly in the RESchecksoftware Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception Is being claimed. Where compliance is itemized in a separate table, a reference tothat table is provided. Section Plans Verified Field Verified # Pre-inspection/Plan Review Value Value Complies? Comments/Assumptions 103.2 Construction drawings and fiComplies [PR111 documentation demonstrate E]Does Not I energy code compliance for the EINot Observable building envelope. !E]Not Applicable 103.2, :Construction drawings and jElComplies 403.7 documentation demonstrate ElDoes Not [PR311 energy code compliance for �E]Not Observable -0) Jighting and mechanical systems. Systems serving multiple tlNot Applicable :dwelling units must demonstrate compliance with the commercial 403.6 Heating and cooling equipment is Heating: Heating: ElComplies [PR2]2 sized per ACCA Manual S based Btu/hr Btu/hr ElDoes Not !on loads per ACCA Manual J or Cooling: Cooling: �E]Not Observable 14 other approved methods. Btu/hr— Btu/hr E]Not Applicable Additioma[ Cmmmmnmmts/Assmmnpt1oms: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low impac-t-(-Tie­r-3)---] Project Title: Proposed New Residence Lot 3, 303 Abbott Street Report date: 1I/24/1 Data filename: C:\0l'Pro]ect$Res|denda|\Corcoran'NorthAndover\lO-EnergyAudits\Abbott- Lot 3.rck Page 3of A � � _T 2009 IECC Foundation Inspection Complies? Comments/Assumptions 30 A protective covering is installed to ;❑Complies [Ft`J1�j�' �protect exposed exterior insulation �❑Does Not I and extends a minimum of 6 in. below ;❑Not Observable', grade. j❑Not Applicable 4F Snow-and ice-melting system controls ❑Complies �F(��� z )Installed. ❑Does Not r ❑Not Observable; j❑Not Applicable Additional Comments/Assumptions: i I 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Proposed New Residence- Lot 3, 303 Abbott Street Report date: 11/24/1 Data filename: C:\01-Projects\Residential\Corcoran-North Andover\10-Energy Audits\Abbott- Lot 3.rck Page 4 of 9 Section Plans Verified Field Verified # Framing/ Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Door U-factor, U- U- ❑Complies ;See the Envelope Assemblies 402.3.4 ,❑Does Not :table for values. [FR1]1 ❑Not Observable P " ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ;❑Complies ;see the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.5 ❑Not Observable [FR2]1 ;❑Not Applicable i 303.1.3 U-factors of fenestration products` t❑Complies [FR411 :are determined in accordance flDoes Not (with the NFRC test procedure or 110 ;taken from the default table. ❑Not Observable ❑Not Applicable 402.3.5 Sunrooms enclosing conditioned U- U- ❑Complies [FR8]1 (space have a maximum ❑Does Not p jfenestration U-factor of 0.50 in j❑Not Observable Climate Zones 4-8. New glazing E❑Not Applicable :separating the sunroom from P conditioned space must meet :code requirements. 402.3.5 Sunrooms enclosing conditioned U- U ❑Complies [FR9]1 :space have a maximum skylight ❑Does Not U-factor of 0.75 in Climate Zones 4-8 : ❑Not Observable ❑Not Applicable 402.4.4 Fenestration that is not site built 1 l❑Complies [FR20]1 is listed and labeled as meeting ( j❑Does Not 10, �AAMA/WDMA/CSA 101/LS.2/A440 $ or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code i �❑Not Applicable , limits, r 402.4.5 IC-rated recessed lighting fixtures; {❑Complies 016,12 !sealed at housing/interior finish r �❑Does Not !and labeled to indicate-2.0 cfm leakage at 75 Pa, l❑Not Observable ❑Not Applicable 403.2.1 ;,Supply ducts in attics are ; R- R- ;❑Complies [FR12]1 insulated to >_R-8.All other ducts ' R_ R_ ❑Does Not in unconditioned spaces or j outside the building envelope are ;❑Not Observable i Insulated to >_R-6. ;❑Not Applicable 403.2.2 ;All joints and seams of air ducts, fi❑Complies [FR13]1 :air handlers,filter boxes, and l❑Does Not :building cavities used as return ' �E]Not Observable :ducts are sealed. I ❑Not Applicable 403.2.3 Building cavities are not used for ❑Complies [FR15]3 supply ducts. ❑Does Not 1❑Not Observable bNot Applicable 403,E HVAC piping conveying fluids R- R- ;,E]Complies [FR'I712 above 105°F or chilled fluids ! ;❑Does Not below 55 °F are insulated to >_R- 4 ?3 ;❑Not Observable ❑Not Applicable 403,4 ;Circulating service hot water R- R- ❑Complies [FRl8]2 pipes are insulated to R-2. : ❑Does Not ; ' '❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Proposed New Residence- Lot 3, 303 Abbott Street Report date: 11/24/1 Data filename: C:\01-Projects\Residential\Corcoran-North Andover\10-Energy Audits\Abbott- Lot 3.rck Page 5 of 9 Section Plans Verified Field Verified # Framing /Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 4153,5 !Automatic or gravity dampers are ❑Complies 1 Et19z installed on all outdoor air ;❑Does Not �y intakes and exhausts. 0 i -i'❑Not Observable ( �❑Not Applicable Additional Comments/Assumptions: it 1 High Impact(Tier 1) 2Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Proposed New Residence- Lot 3, 303 Abbott Street Report date: 11/24/1 Data filename: C:\01-Projects\Residential\Corcoran-North Andover\10-Energy Audits\Abbott- Lot 3.rck Page 6 of 9 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 031 ;All installed insulation is labeledg t❑Complies [IN131 or the installed R-values y T❑Does Not i provided. I a o❑Not Observable ❑Not Applicable 402.1.1, Floor insulation R-value. R- R- ;❑Complies ;See the Envelope Assemblies 402.2.5, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 ❑ Steel ❑ Steel ;❑Not Observable [IN1]1 ;❑Not Applicable 303.2, ;Floor insulation installed per �❑Complies 402.2.6 ^manufacturer's instructions, and ❑Does Not [IN2]1 in substantial contact with the underside of the subfloor, ; ❑Nat Observable I❑Not Applicable 402.1.1, :Wall insulation R-value. If this is a: R- R- ❑Complies ;See the Envelope Assemblies 402.2.4, mass wall with at least 1/z of the ❑ Wood ❑ Wood o❑Does Not table for values. 402.2.5 ;wall insulation on the wall 1❑ Mass ❑ [IN3]1 exterior, the exterior insulation Mass ❑Not Observable p 1 requirement applies. ❑ Steel ❑ Steel ❑Not Applicable o l 303.2 Wall insulation is installed per i❑Complies [IN4]1 manufacturer's instructions. n I❑Does Not I f UNot Observable ❑Not Applicable 402.2.11 ;Sunroom wall insulation has a R- R- ;❑Complies [IN8]1 I minimum R-value of R-13. New ❑Does Not ;walls separating the sunroom 1 !from conditioned space must ;❑Not Observable a meet code requirements. ;❑Not Applicable 303.2 ;Sunroom wall insulation installed �❑Complies [IN9]1 :per manufacturer's Instructions. ( ;❑Does Not 1 ❑Not Observable t❑Not Applicable 402.2.11 Sunroom ceiling minimum R- R- ;❑Complies [IN10]1 I insulation R-value of R-19 in ❑Does Not ;Climate Zones 1-4, and R-24 in 10-11 ,Climate Zones 5-8. I ;❑Not Observable ; ❑Not Applicable 303.2 ;Sunroom ceiling insulation is ;❑Complies [IN11]1 installed per manufacturer's ❑Does Not Instructions. (❑Not Observable 1 Q �❑Not Applicable Additional Comments/Assumptions: 1 1 High Impact (Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Proposed New Residence - Lot 3, 303 Abbott Street Report date: 11/24/1 Data filename: C:\O1-Projects\Residential\Corcoran-North Andover\10-Energy Audits\Abbott- Lot 3.rck Page 7 of 9 Section Plans Verified Field Verified # Final inspection Provisions Value Value Complies? Comments/Assumptions & Reci.ID 402.1.1, ;Ceiling insulation R-value.Where R- R- ;❑Complies ;see the Envelope Assemblies 402.2.1, > R-30 is required, R-30 can be ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2 ,used if insulation is not [Fill' compressed at eaves. R-30 may ;E] Steel ❑ Steel !❑Not Observable p be used for 500 ftz or 20% ;❑Not Applicable (whichever is less)where !sufficient space is not available. 303.1.1.1, ,Ceiling Insulation installed per $ i❑Complies 303.2 manufacturer's instructions. t ❑Does Not [FI21' Blown insulation marked every Itip 1300 ft2. ❑Not Observable j t❑Not Applicable 402.2.3 ;Attic access hatch and door R- R- ❑Complies [FI3]' !insulation ?R-value of the :❑Does Not adjacent assembly. j ❑Not Observable ❑Not Applicable 402.4.2, ;Building envelope tightness ACH 50 = ACH 50 = {❑Complies 402.4.2.1 !verified by blower door test result: ❑Does Not [FI17]' of<7 ACH at 50 Pa.This !requirement may instead be met ❑Not Observable ,via visual inspection, in which ❑Not Applicable case verification may need to ,occur during Insulation Inspection. 40 .4 I'Wood burning fireplaces have i {❑Complies (FI$]2 �gasketed doors and outdoor I E❑Does Not combustion air. 5 ❑Not Observable � f t❑Not Applicable 403.2.2 Post construction duct tightness cfm cfm ❑Complies [FI4]' :test result of:58 cfm to outdoors, ;❑Does Not or<12 cfm across systems. Or, '❑Not Observable rough-in test result of<6 cfm ,across systems or_<4 cfm ❑Not Applicable :without air handler. Rough-in test; ! :verification may need to occur ! :during Framing Inspection. ! ! 403.1„l Programmable thermostats ❑Complies [Fl9]2 installed on forced air furnaces. Q ❑Does Not l ;❑Not Observable El Not Applicable j 40 ,1.2 ;Heat pump thermostat installed ; ❑Complies [FIx0] on heat pumps. o ❑Does Not ❑Not Observable 5 t❑Not Applicable 40$.4 }Circulating service hot water o �❑Complies [F111"] !systems have automatic or �❑Does Not !accessible manual controls. t❑Not Observable a I T❑Not Applicable 403.9.1 j Readily accessible switch on ❑Complies [FI12]3 heaters for swimming pools. ;❑Does Not ! y❑Not Observable �E]Not Applicable 403.9,2 ,Timer switches on pool heaters {❑Complies [FI19]3 :and pumps are present. ❑Does Not ❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Proposed New Residence- Lot 3, 303 Abbott Street Report date: 11/24/1 Data filename: C:\O1-Projects\Residential\Corcoran-North Andover\10-Energy Audits\Abbott- Lot 3.rck Page 8 of 9 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.9.3 Heated swimming pools have a l ❑Complies [1`120]3 cover. Covers on pools heated ❑Does Not over 90°F are insulated to R-12. ; ❑Not Observable �❑Not Applicable 404.1 ;50%of lamps in permanent I❑Complies [F16]1 ifixtures are high efficacy lamps. ❑Does Not `til' ; ; _ J❑Not Observable j❑Not Applicable 401.3 1Compliance certificate posted. {❑Complies (Fi712 , t❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ; N❑Complies [FI18]3 ;mechanical and water heating ❑Does Not equipment have been provided. i ?❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Proposed New Residence- Lot 3, 303 Abbott Street Report date: 11/24/1 Data filename: C:\01-Projects\Residential\Corcoran-North Andover\10-Energy Audits\Abbott- Lot 3.rck Page 9 of 9 2009 IECC Energy Effidency Certificate ME Wall 21.00 Floor 30.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): I Window 0.29 Door 0.60 IIIIIIIIIIIIIIIIIIINION . .. . . Heating System: Cooling System: Water Heater• Name: Date: Comments