Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Building Permit # 2/23/2015
y.'ORTH OF� '611+ BUILDING PERMITS oL TOWN OF NORTH ANDOVER ° ; °1 APPLICATION FOR PLAN EXAMINATION „ Perrnit N0: Date Received ryst �A�7ED PPP,`+(y Date Issued: ��� � SSACHU`�E _ _ IMPORTANT: Applicant must complete all items on this pa 7e LOCATION 206 Forest St North.Andover, MA 01845 PROPERTY OWNER Lorenrl BeaCh print Print MAP NO: 107' PARCEL: s ZONINGDISTRICT: R2' Historic District yes no ✓' Machine Shop Village yes no — -_. TYPE OF IMPROVEMENT PROPOSED USE _ _ Residential Non- Residential New Building ✓ One family Addition - Two or more family Industrial XAlteration No. of units: Commercial Repair, replacement - Assessory Bldg - Others: Demolition - Other J Septic LJ Well �J Floodplain J Wetlands I ''Watershed District J Water/Sewer INSTALL A ROOFTOP SOLAR ARRAY LAGGED INTO THE HOMES ROOF RAFTERS JAJI... _ Identification Please.Type or Print Clearly) OWNER: Name: Lorene Beach Phone: 978-686-8121 Address: 206 Forest Street North Andover, MA 01845 CONTRACTOR Name: Daniel Goodridge Phone: 339-227-2003 - Address: 8955 Henkels Lane S ite;508 Annapolis, MD 20701 I Supervisor's Construction License: Exp. Date: 107691 1/26/18 Horne Improvement License: 16822$ Exp. Date: ARCHITECT/ENGINEER ELAINE HUANG P.E. Phone: 978-406-8921 Address:35 KENDALL CT BEDFORD,MA, Reg. No,49029 FEE SCHEDULE:BULDING PERMIT:$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F. Total Project Cost: $3 fie FEE: $ o� ChE.ck No.: Receipt No.: \'OTE: Persons corltr ac4irag with unregistered eontr actors do riot have acce s•to he gar I irrrd F Signature of Agent/Own � a/I J cSjqnature of contractor . a t%ORTH Town of ndover 0 _n No. 66S.0 h ver Mass, 0 coc 1W.C. ti oj�ATED BOARD OF HEALTH Food/Kitchen PERMIT T LD Septic System 400"A THIS CERTIFIES THAT .......... .. CAa 'P .......... BUILDING INSPECTOR................... Foundation has.permission to erect .......................... buildings on ..........Z*... . .. ... ........ ................... Rough to be occupied as Chimney .... .. .... .. provided that the person accepting this permit shall in every respect conform to the terms of the application Final on file in this office, and to the provisions of the Codes and By-Laws relating to the Inspection, Alteration and Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR VIOLATION of the Zoning or Building Regulations Voids this Permit. Rough Final PERMIT EXPIRES IN 6 MONTHS ELECTRICAL INSPECTOR . UNLESS CONSTRUC I STARTS Rough Service ........... ...... ............ ......................................... Final BUILDING INSPECTOR GAS INSPECTOR Qecgeancy Perinit Required to Occupy Buildin Rough Display in a Conspicuous Place on the Premises — Do Not Remove Final No Lathing or Dry Wall To Be Done FIRE DEPARTMENT Until Inspected and Approved by the Building r® Burner Street No, Smoke Det. 8 955 Herikels Lane, St..Jte. 608 w Annapolis 3 U1-1Cti0rt, NID 2:0701 P1-10KIE.`1800 902.6130 FA xl.44 3,267,0036 S T R U i` SOL R" WWW.k3st:ui.U111SO lar COPD February 18, 2015 To: Town of North Andover 120 Main Street North Andover, MA 01845 Subject: Structural Certification for Installation of Solar Panels Beach Residence 206 Forest Street North Andover, MA.01845 To Whom It May Concern, A design check for the subject residence was done on the existing roofing and framing systems for the installation of solar panels over the roof. From a field inspection of the property,the existing roof support structures were observed by Astrum Solar auditors as follows: The roof structure of(Roof A)consists of composition shingle on roof plywood that is supported by nominal 2x6 rafters @ 16"o.c.,paired with nominal 2x6 ceiling joists @ 16"o.c..There are 2x6 collar ties at every rafter which frame out an enclosed attic.The rafters are supported mid-span by veritcal struts which work with collar ties and ceiling joists to provide a truss system to support the rafters above.The rafters have a max projected horizontal span of 6'-6",with a slope of 45 degrees.The rafters are connected at the ridge to a continuous 2x8 ridge board and are supported at the eave by a load bearing wall. The roof structure of(Roof B)consists of composition shingle on roof plywood that is supported by nominal 2x10 rafters @ 16"o,c.,paired with nominal 2x8 ceiling joists @ 16"o.c..The rafters have a max projected horizontal span of 12'-0",with a slope of 45 degrees.The rafters are connected at the ridge to a continuous 2x12 ridge board and are supported at the eave by a load bearing wall. The roof structure of(Roof C)consists of composition shingle on roof plywood that is supported by nominal 2x6 rafters @ 16"o.c.,paired with nominal 2x8 ceiling joists @ 16"o.c..The rafters have a max projected horizontal span of 11'-1",with a slope of 45 degrees.The rafters are connected at the ridge to a continuous 2x8 ridge board and are supported at the eave by a load bearing wall.There are 1x8 vertical struts at 16"o.c.that is approximately 8'-0"from the ridge to provide extra bracing to the rafters. The existing roof framing system of(Roof A)is judged to be adequate to withstand the loading imposed by the installation of the solar panels. No reinforcement is necessary. The existing roof framing system of(Roof B)is judged to be adequate to withstand the loading imposed by the installation of the solar panels. No reinforcement is necessary. The existing roof framing system of(Roof C)is judged to be inadequate to withstand the loading imposed by the installation of the solar panels.Structural reinforcement is required. New 2x6(min)x T-0"long collar ties shall be installed at 16"o.c.with 6- 10d nails at each end on(Roof C). 5� F A "ALIT i"I ,fflurk', R,'�A '�41 H"H F Beach Residence, Andover 1 r9 8955 F-ler7kels Lane, S4.lite 5103 U, AnnaEjuli;Junction, NID 20701. �A PH O11JL 1 X80 903.51 3O FAX 443u267,C)036 ST UM L ., vswwaskrunisolar.corwi The spacing of the solar standoffs should be kept at 48"o.c.with a staggered pattern to ensure proper distribution of loads. I further certify that all applicable loads required by the codes and design criteria listed below were applied to the Unirac Solarmount solar rail system and analyzed. Furthermore,the installation crews have been thoroughly trained to install the solar panels based on the specific roof installation instructions developed by Unirac Solarmount for the racking system and Ecofasten for the roof connections. Finally, I accept the certifications indicated by the solar panel manufacturer for the ability of the panels to withstand high wind and snow loads. Design Criteria: • Applicable Codes=Massachusetts Residential Code,8th Edition,ASCE 7-05,and 2005 NDS ® Roof Dead Load=12 psf(Roof A) -- 9 psf(Roof B) -- 8 psf(Roof C) • Roof Live Load=20 psf ® Wind Speed=100 mph, Exposure C ® Ground Snow Load=50 psf - Roof Snow Load=35 psf Please contact me with any further questions or concerns regarding this project. Sincerely, '!,0CN r1F4 y ELAINE-"A. �cn iWANr CIVIL Elaine Huang, P.E. NG.49tog Project Engineer = �` fl� i4VL�'U'r+i I I)'AN" 1,1 A"' P?11i r'- r47"""" Beach Residence, Andover 2 i *130!isrsdaof Mcht4sett's-Department of Pub1(a Safety ' Building negulations arid Stalyclarrls Clrhatructlon Sthtr�i�s�t~ 7� License: CS407691 I ' DANIEL R OOODAMGE 60 CAItUSLE MAD"," Bedford MA 017SO i t` t Expiration Commissioner 01/26/2018 _ C3 ce of�onsun�..er.A.ffarx ani.Business R_egul�,�ic�n _ 10 Park Plaza- Suite 5170 Boston, AJ-4c 'usetts 02116 Home Improve r-_r� Contractor Registrations Registration: 168228 Type: Supplement Gard ASTRUM SOLAR INC. Expiration.: 1/19/2017 DANIEL GOODRIDGE 8055 HENKELS LANE STE 508 ANNAPOLIS, MD 20701 ' ``= ='V ' Update Address and return card.Mark reason for Change, n Address Ej Renewal F-1 Employment (�host Gard DPS-GA1 0 50M�(79/0q-G101216 .1PtL'(UGvyJL77Za-7LGUP-Iit/s2+?�..fL'"LeFddc�GtttdeG�d -- OtBce of Cbnsumer.A.ffairs Bc BuslOss Regulaiiou License or registration valid for individul use only HOME IMPROVEMENT CONTRACTOR bei 0re.the expiration date. Iffound return to- Office of Consumer Affairs and Business Regulation -- ; Registration. gSg228 Type: 10 Park Plana,-Suite 0 ExpiraffiN.—g7 1.Z, - Supplement Card on X19 ASTRUM SULMR'!V DANIEL $955 H1=NKELS -- ANNAf?OLIS,MR20701' _``' 0adersecretary Notvalidivithoptsiggature AC"R"� CERTIFICATE LIABILITY DATE(MM/DD/YYYY) Page 1 of 1 02/04/2015 THIS CERTIFICATE IS ISSUED ASA MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.Astatement on this certificate does not conferrights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Willis of Texas, Inc. PHONE FAX c/o 26 Century Blvd, - 877-945-7378 888-467-2378 P.O. sox 305191 E-MAIL certificates@willis.com Nashville, TN 37230-5191 INSURER(S)AFFORDINGOOVERAGE NAIC# INSURERA:ACE American Insurance Company 22667-302 INSURED Direct Energy and its majority owned INSURERB: Zurich American Insurance Company 16535-305 subsidiaries and affiliates including INSURERC:American Zurich Insurance Company 16535-306 Astrum Solar 5 Lyberty Way, Suite 3 INSURER D: Westford, MA 01886 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER:22748483 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN. THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPEOFINSURANCE DDL SUB POLICY NUMBER POLICY EFFfyyyy� POLICYEXPITR LIMITS A X COMMERCIAL GENERAL LIABILITY XSLG27341226 1/1/2015 1/1/2016 EACHOCCURRENCE _ $ 11000,000 DDAA�q pT RENTED CLAIMS-MADE OCCUR PFtEMESQEaoccurence) $ 100,000 X SIR: $500,000 MED EXP(Any one person) $ 5,000 PERSONAL&ADV INJURY $ 1,000,000 GEMLAGGREGATELIMITAPPLIESPER: GENERAL AGGREGATE $ 11000,000 POLICY [--X] PRO ❑JECT LOC PRODUCTS- $ 1,000,000 OTHER: $ $ AUTOMOBILE LIABILITY BAP595396601 1/1/2015 1/1/2016 COMBINED SINGLE LIMIT 1,000,000 (Ea accident) $ X ANYAUTO BODILY INJURY(Per person) $ ALLOWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS AUTOS HIR DAUTOS NON-OWNED PROPERTY DAMAGE AUTOS (Peraccident) $ * X UMBRELLALIABX OCCUR XOOG25703728 1/1/2015 1/1/2016 EACHOCCURRENCE $ 2 000 000 '.. EXCESS LIAB CLAIMS-MADE AGGREGATE $ 2,000,000 DED I RETENTION$ $ C+ WORKERS COMPENSATION WC595396901 1/1/2015 1/1/2016 X STAPER OTH- ER AND EMPLOYERS'LIABILITY B ANY PROPRIETOR/PARTNER/EXECUTIVE N/A WC595397301 1/1/2015 1/1/2016 E.L.EACH ACCIDENT $ 11000,000 OFFICER/MEMBER EXCLUDED? f Mandatory inNH) E.L.DISEASE-EA EMPLOYEE $ 1,000,000 ff yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 1,000,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additonal Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE Town of North Andover 206 Forest St North Andover, MA 01845 Coll:4618435 Tpl:1917373 Cert:22748483 @ 19881,z2014ACORDCORPORATION.Allrightsreserved. ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts Prirrl Forrri� Department of Industrial Accidents Office of Investigations r I Congress Street, Suite 100 Boston,MA 02114-2017 -, www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Astrum Solar Address: 15 Avenue E City/State/Zip: Hopkinton, Ma, 01748 Phone 4:508-614-0146 Are you an employer?Check the appropriate box: Type of project(required): 1.0 I am a employer with 15 4. ❑ I am a general contractor and I employees(full and/or part-time).* have hired the sub-contractors 6. ❑New construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. Remodeling ship and have no employees These sub-contractors have g. ❑Demolition working for me in any capacity. employees and have workers' 9. ❑Building addition [No workers' comp.insurance comp.insurance.$ required.] 5. ❑ We are a corporation and its 101-1 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑Roof repairs insurance required.] c. 152, §1(4),and we have no PV Solar Installation employees. [No workers' 13.❑✓ Other comp.insurance required.] *Any applicant that checks box#1 must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. tContractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I ant an employer that is providing ivorkers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:Zurich American Insurance Co. Policy#or Self-ins.Lia#: 59536900 Expiration Date:1/1/16 Job Site Address4c>(.. rOres+ 5 + City/State/Zip:/uV4 "Uec Iyfl 0t St-{ Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORD ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certif under the gins and enalties of erjur that the information provided above is true and correet. Signature: — — ---- Date: Phone#: Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3. City/Town Cleric 4.Electrical Inspector 5.Plumbing Inspector 6. Other Contact Person: Phone#: TOWN OF NORTH ANDOVER � � � AFFIDAVIT Home Improvement Contractor Law Supplement toPermit Application MGL c 142A requires that the^reconatmction, aberation, renovation, repair, modennization, conversion, improvement, removal, demolition, or construction of an addition to any pre-existing owner occupied building containing at least one but not more than four dwelling units...or to structures which are adjacent to such residence or building" be done by registered contnaotom, with certain exception, along with other requirements. k �_- Type Of��O[k Est. Cost 71 Address Of WO OVVD8[ K]80ej Date OfPermit Application: I hereby certify that: Registration is not required for the f0)lOVYiDg Fe8SOD/S\: For OffiCe Use Only � [k eXC|Ud8d by |8VV Permit ND.________ � Ob under $1'000 Date AUildiDg not OVVOeFDCCUpi8d Owner pulling OVVD permit | C]the[ (specify) � Notice is hereby given that: OWNERS PULLING THEIR OWN PERMIT OR DEALING WITH UNREGISTERED CONTRACTORS FOR APPLICABLE HOME IMPROVEMENT WORK DONOT HAVE ACCESS TOTHE ARBITRATION PROGRAM OR GUARANTY FIND UNERMGL c. 142A. � Signed under penalties ofperjury: / hereby apply for apermit as the a ent of the owner: � Date Contractor Name Registration No. OR: Notwithstanding the above notice, I hereby apply for a permit as the owner of the above property: Date Owner Name Beach Residence 206 Forest St North Andover,MA 01845 System Ratings ---- N 11.985 kW DC Photovoltaic Solar Array 10.11 kW AC Photovoltaic Solar Array — c o - v� � o > > ¢ n •� Q q N S h Equipment Summary 47 Qcells 255 poly black Modules 47 Enphase M215-60-2LL-S22 Inverters 107 Roof Attachments E Sheetlndex o o p 0 0 0 PV-1 Cover PV-2.1 Description of Work and Load Calculations- RoofA o g PV-2.2 Description of Work and Load Calculations- RoofB --- --- -- -- - -- - --- --- - PV-2.3 Description of Work and Load Calculations- Roof C 0 PV-3 Electrical Diagram PV-3.1 Electrical Calculations N PV-4 String and Conduit Layout PV-5 Equipment Ratings and Signage of4 s 0 Governing Codes 2014 National Electric Code 2009 International Building Code Underwriters Labratories(UL)Standards OSHA 29 CFR 1910.269 ASCE-7-05 c 0 0 N 0O oa o` ¢ � a0 m N Z N Q1 N N 0 C) U PV-2 Roof A Typical section 5.865 kW DC Photovoltaic Solar Array This solar array Is comprised of 23 ocells 255 poly black solar panels.The panels are mounted using the Unfmc Solar Mount solar mounting rail uy to the building's 2x6 Rafter,spaced at 16 oc.Each solar panel is attached to an Eophase M215-60-2LL-S22 micro-inverteralo mounted to the Unirac Solar Mount rail directly beneath the panel. N s. ¢,h4 n N 4 wnr,GQ�o�pO�F L � J The solar panels produce DC power when struck by sunlight.The DC power is converted to 240 V AC power at the inverter.Micro-inverters 4NQ� �po5 ro are connected in strings with a maximum number of 17 micro-inverters in each stdng. �� o T E > - \\ Q S F This system will be grid-tied. If the solar panels produce more power than is used by the building,the excess power flows back Into the utility grid through a net meter to be a,,liable for other power users. All metal parts including solar panel frames,micro-inverters,and mounting rails are grounded using the manufacturer's recommended grounding method and W EEB technology along with R6 AW G grounding wire. - E The building was constructed In 1961. ad Y T } 443 544N 9;S11 ¢ O f ,SES W Panel Layout 44 m Pone!Dimensions 65.74 in x 39.37 in System Weight 1499 lbs 11"' 7 Panel Weight 41.91b, System Distributed Load 3.6 psf 44N h - S System Square Footage 413 sq ft RoofSuppart 2x6 Rafter PR�,�e4A Q Actual Point Load Max 4ft Micro-lnverter Weight 101.2 11:m Total number afRoofPenetratlons 49 15", Qo Max Allowable Rail Overhang 16 in Members are Hem,Fir(North)allowing 235 lbs per inch thread depth aid oh Nate 1:Use 5/16"x 4"Hex Head Stainless Steel Lad Screws Variables Not,2:Raaf Support Members are 2x6 Rafter h 24 ft 3k Pne[Downforce 16.5 psf Note 3:Unirac Solar Mount Racking H 18 ft Wind Downforce 16.5 psf Pnet Uplift -21 psf Roof Pitch 45 degrees Wind Uplift -21 psf B 5.5 Load Combinations wMax 147 pif V 100 mph Kzt 1 Dl D2 D3 Uplift Max Span 3f Snow Load 50 psf Exposure Category B Dead Load D 1 3.61 3.6 3.6 2.2 psf Actual Span Oft Roof Zone 3 d i 5now Load 550.0 0.0 37.5 0.0 psf Rd 5881bs E 0 i 1 DWL• Prot i 0.0 16.5 12.4 -21.0 psf Ru 206 lbs u� Total Load p•• 53.6 20.1 53.5 18.8 psf Required Thread Depth 0.88 inde Distrib TL 146.9 55.1 146.5 51.6 plf Actual Thread Depth 2.25 in Q .DWL:Design Wind Load v -Absolute values are indicatedforthe mlculated quantities of P-Uplift and-Uplift e' yo o � o Glossary of Terms for Load Calculations Q ra a h Building Height A Adjustment Factor for height Z H Building Least Horizontal RaafPltch Roof Pitch ! Importance Factor of far a single family residence 0 to tri V Basic Wind Speed O J Q Snowload Snow Load B Module length perpendicular to beam L CO Roof Zone Roof Zone Rd Point Load-Maximum Downforce Q f6 E Effective Roof Area Ru Point Load-Uplift 0 a Roof Zone Setback Length Exposure B-Suburban single family dwelling P,Pt Downforce Net Design Downforce Pressure Category Peet Uplift Net Design Uplift Pressure Xst Topographic Factor PV-2.1 Roof B Typical section 1.785 kW OC Photovoltaic Solar Array This solar array is comprl^ed of 7 011111255 poly black solar panels.The panels are mounted using the Unirac Solar Mount solar ounting rail to the building's 2x10 Rafter,spaced at 16 be.Each solar panel Is attached to an Enphzse 1,4215-60-21-L-S22 micro- O mverteraso mounted to the Unirac Solar Mount rail directly beneath the panel N PY`�E�l��S NQOfl The solar panels produce DC power when struck by-u Ilght.The DC power is converted to 240 V AC power at the Inverter.Micro- EH GOxt,40 ua inverters are connected In strip€s with a maximum number of 17 micro-Inverters In each string, vro e m O T C no Q :Sc This system will be grid-tied. If the solar panels produce more power than is used by the building,the excess power flows back into the utility grid through a net meter to be available for other power user•.. All metal part-Including solar panel frames,micro-inverters,and mounting rails are grounded using the manufacture,,recommended grounding method and W EEB technology along with 96 AWG grounding wire, v The building was constructed In 1961. ZEENO 0 0 p3-J�HJ, ECOO���N O C N m Panel Lavout H_ZEE , �ZLpE Panel Dimensions 65.74 in x 39.37 in System Weight 456 16s s N�E Panel weigh[ 41.91bs System Distributed toad 3,6 psf EE - p4s QOpS N`E�EE0.Z Q System Sgvarl Footage "111" 26sqft Roof Support 2x10 Rafter Racking Weight 1321b, Actual Point Load Max Spacing 4 ft JQ Micro-inverter Weight 30.81bs Total number afRoofFene[rotions 21 P� 11 Max Allowable Rail Overhang IS in allowing the per inch thread depth Note 1:Use 5116"x 4'Hex Head Stainless Steel Lag Screw, Variables Nate 2.Raaf Support Members ore 2x10 Rafter h 24 ft a aft Pne[Downforce 16.5 psf Note 3:Unimc5olorMount Racking H 18 ft Wind Downforce 16.5 psf Pnet Uplift -21 psf Roof Pitch 45 degrees Wind Uplift -21 psf B 5.5 Load Combinations wMax 147 PH V 100 mph Kzt 1 Dl D2 D3 Uplift I Max Span 3 ft Snow Load 50 psf Exposure Category B Dead Load D 1 161 3.6 3.6 2.2 1 psf Actual Span 4i Roof Zone 3 7, 1 Snow Load 5 SOA 0.037.5 0.0 psf Rd 587 lag E 0 ( 1 DWL' Pnet i 0.0 16.5 12.4 -21.0 psf Ru 206 Has Total Load p" i 53.6 20.1 53.5 18.8 psf Required Thread Depth 0.88 in W Distrib TL w" 146.8 55.1 146.5 51.6 plf Actual Thread Depth 2.25 in o Q *DWI:Design Wind Load **Abso/uteva/ues are indicated for the calculated quantities ofP-Uplift w-Uplift m 'D 0 p v Glossary of Terms for Load Calculations h Building Height A Adjustment Factor for height mm p Z H Building Least Horizontal Roof Pitch Roof Pitch i Importance Factor of fora single family residence p tovy V Basic Wind Speed C 0 C _ 5»ow Load Snow Load B Module length perpendicular to beams 0 '6 j0_.r RaofZone Root Zone Rd Point Load-Maximum Downforce Q C E Effective Roaf Area Ru Point Load-Uplift U Y U a Roof Zone Setback Lengthur &posura B-Suburban single family dwelling OJ O Cto Pnet Downforce Net Design Downforce Pressure category Poet Uplift Net Design Uplift Pressure Kzt '']] Topographic Factor PV-2.11 � 4 - 21 s oDi_ o w o c g a v 2 z a o c o o 3 N T£ 3 a a �.3 _ OU E 2 _ A w 3 _ " oc 3 n O M k _ - N Q OQ Ao n bC p a N e 3 o a � 3 a � 3 3 oy o 3 3 a o 10 3 3 �• n 4 n C - 4E2 b b, d n a x S m 3 c a c s a F a \ a 5 OOG E D a s a £ P� oy `�'qJ.�• tl y --�POrtr Yn N ti O a sa cvo y s oP "k ��Co m s py r OA x x V Te Revisions Date Remarks Astrum Solar,Inc. Beach Project Description of *' 1 MM/DD/YY 15 Avenue a Work and Load w Calculations 201 Forest It ASTRUMSOLAR 2 MM/DD/YY Hopkinton,MA,01748 North Andover,MA 01845 3 MM/DD/YY Thursday,January 22,2015 G +� G G — oy x 3 egg � m CF u�j, �1 r m 0 1ZM ill .. < 0 1MM N m R o iti �r �gy m m d tFFiii �� � p 1 1 � ✓d,✓y .pn � � m m ..... -............. ....� ........... , EKa............ Revisions Date Remarks Astrum Solar,Inc. Beach Project CElectrical 1 MM/DD/YY 15Avenue E t , Diagram 206 Forest St A5'I"12llMSC7L.A1R.^, 2 MM/DD/YY Hopkinton,MA,01748 . North Andover,MA 01845 3 MM/DD/YY Thursday,January 22,2015 Electrical Diagram for Beach-11.985 kW DC Photovoltaic Solar Array Calculation for PV Breaker PV Array Wiring Caleutation PV Service Wiring Calculation Calculation for Main PV Breaker&Circuits Fr9iamfumWire Si7e910AWG v'= alc= [RiOimumWireSiae#4AWG €eCa'c ti System Current= 47 X 0.9 = 42.3 Amps WIRE SIZING CALCULATION WIRE SIZING CALCULATION o 2D1112014 NEC Article 310 201112014 NEC Article 310 m Design Amperage= 42.3 X 125% = 52.875 Amps Full Load Amperage.._.___.:126 Full Load Amperage 42.3 N Main Buss Rating= 200 X 120% = 240 Amps Source Voltage___._.....:240 Source Voltage.___._._..:240' O Existing Main Breaker = 200 Amps Length of Run(Feet)....____:9D Length of Run(Feet)._—_:30 Max Solar Breaker zoo (-) 200 — 40 Amps LoadDuiy._ _:Continuous Load Duty__ _.:Continuous Circuit#1= 11 X 0.9x 125%= 12.375 Amps Conductor Application_._...:Condudors in Raceway,Cable or Earth CondudorApplication._._..-:Conductors in Raceway,Cable or Earth o a CondudorAmpacityTable_.._:NECTable310-15(B)(16) Conductor Ampacity Table.._.-.:NECTable310-15(9)(16) E E Circuit#z= 11 X 0.9x125%= 12.375 Amps CondudorType_ .:THHNCopper Condudor7ype_._.__....:THHNCopper a �- Circuit p3= 14 X 09X125%= 15.75 Amps ConductorLocation_._—:Dry@amp Conductor Location,..___...__.:DrylDamp ¢ _ Circuit#4= 11 X 0.9x125%= 12.375 Amps Conductor Insulation Temperature:90'C Con ductorinsulationTemperature:90'C Rooftop Installation:N EC 31 DASCB)(3)(c) Ambient Tempe rature__—:26-30'C=78-86'F Distance Above Roof_._....-:Above 13 mm to 90 mm[above 112 inch to 3112 inch] Terminal Temperature Rating_.:60'C Average Outside Temp.....:90 Deg.F 322 Deg.C Circuit Type:Single Phase 3 Wire(2 phase conductors&neutral) Temperature Adder______:40 Deg.F22 Deg.C Qty.of Circuit Current-Carrying Conductors:2 Conductor Requirement Adjusted Ambient Temperature_.:130.0 Deg.F542 Deg_C Full Load Amps------:42-3 E Terminal Temperature Rating._:60'C Load Duty Multiplier__:125 Circuit Type:Single Phase 3 Wire(2 phase conductors&neutral) Ambient Temp.Multiplier-:1-G } } Oty.of Circuit Current-Carrying Conductors:2 > > Additional Current-Carrying Conductors__:6 -Conductors Multiplier:1.0 0 0 0 0 0 0 Required CondudorAmpacity.52-86 °1 g Total Qty.Current-Carrying Conductors_..._:8Terminal Requirement o 2 2 2i Conductor Requirement Full Load Amps_..---:423 Full Load Amps__.__.:126 Load Duty Multiplier_....125 Load Duty Multiplier__:125 0 Ambient Temp.Multiplier.:1.32 Required Terminal Ampacity:5288 .a City.Conductors Multiplier:1,43 Selected Conductor. m Conductor Ampacity._._:70.0 Required Conductor Ampacity:29.7 Ambient Temp.Derate_-_:1.0 Terminal Requirement City.Conductors Derate_.:1.0 Full Load Amps____:126 Load Duty Multiplier—:125 � Adjusted Ampacity___:70.0 � SELECTED CONDUCTORSIZE:4Awg Required Terminal Ampacity:15.75 2 x Ohmsll.Wt x Length x Amps 2x 0308 x 30 x 52.88 Selected Conductor. VD= _ =078 Conductor Ampacity 30.0 1000 x Ambient Temp.Derate_.:0.76 Qty Wires per Phase 1000x 1 OtY-Conductors Derate_..:0.7 Volts At Load Term ralsi:239-22 Actual Percent Voltage Drop_:033 Adjusted Ampacity.Y._:15.96 Electrical Notes SELECTED CONDUCTOR SIZE:10 Awg 1)All equipment to be listed and labeled for Its application. 2 x Ohms!@.AAR x Length x Amps 2 x 1.24 x 90 x 29.7 VD= 2)All conductors shall be copper,rated for 90C and wet environment,unless 1 oQo X Qty Wires per Phase 1000 x 1 ofharwiza noted. Volts At Load Terminals:237.9 9 3)Working clearances around al new and exlstingelectrical equipment shall Actual Percent Voltage Drop.:1.17 ompiywith NEC110.26 4)All wire terminations shall be appropr1.tely labeled and read1lV,1,ab1e. 5)Module groundingclips to be Installed between module frame and module Q support rail,per grounding clip manufacturers 1-trualon. � O 6)Module Support Wl to be banded to continuous copper GEC via WEEB lug per m C NEC 690A(C). t0 7)If used PV power source breaker to to located at bottom of bus per NEC m N Z 690.64(B)(7). B)AC combiner pane(,shall be labeled,,'Invertor AC Combiner P-al". N C a p 9)Listing ag,,ryn,ne—d—b—to bo Indicated on invortersand modules per NEC 110.3(B) y U 10)PV powersource breakerto be suitable for backfood per NEC 690.64(8)(5). N U W no V PV-3.1 Wiring Description Beach,Lorene.Residence Electrical Review 206 Forest St.North Andover,MA 01845 Westford,MA Office:Eric Collins Reviewed By:Seth Cisco(610-283-3112) v Financing:Purchase � 0 c 2 (47)Qcells 255w Panels with(47)M215 Inverters � PV meter type:Locus Lgate 120 N wo Emu location:near the main electrical panel. E w Internet Connection:Bridge ¢ n. Main Electrical Panel: Cutler-Hammer(200 Amp) =o Circuit Calculations:47 M215 inverters x.9/Inverter=42.3 Amps x 1.25=52.875FLA. PV combiner with(3)15 Amp,2 pole circuit breaker,(1)20 Amp,2 pole circuit breaker,(1)15 Amp,1 pole circuit breaker(for EMU) Interconnection calculation:N/A,Line-Side-Tap E a Interconnection will be aline-side-tap in the gutter space of the existing 200 Amp service disconnect located in the basement.From the LST instill wiring to a 60 Amp fused disconnect switch with 60 Amp fuses mounted adjacent to the main cc � i > service disconnect(May need to mount backer board).Wiring from this fused disconnect switch will install outside to a 60 Amp non-fused disconnect located next to the utility meter.From the disconnect switch,wire through the PV meter and o 0 0 then into the PV combiner panel.From the PV combiner panel,run exterior conduit up the wall to a penetration into the attic.Continue through the attic space to the two soladeck under the two solar arrays as shown in the drawing.From the a second soladeck,run conduit through the attic to a penetration outside towards the garage.Continue down the wall and on the back to the house to a junciton box located under the last solar array.All roof mounted conduit must be at least 1" o above the roof surface and flash supported properly.There will be four circuits of inverters. Install an outlet for the EMU at the location where the EMU will be mounted.If this location is in a garage or basement install a GFCI outlet.Wiring for this outlet will be from the PV combiner panel and can be OF type cable. a � N Circuit 1 (11) 3 Q Circuit 2(11) Circuit 3(14) 4 Circuit 4(11} a Junction Box I SOiadeck Ij 1 Enphase End Capp a ti Enphase Cable a Interior Conduit > 0 Exterior Conduit I s tLL L O ® } l O � J 4 a .- L 0 LO O U PV-4 i l r/ !NO 00 � 101�i r r%rr11110N Pk . a rm ar The new Q.PRO-.63 is the reliable evergreen for all applications. The third 1 module generation from Q CELLS has been optimised across the board: improved output yield, higher operating reliability and durability, quicker installation and more intelligent design. MNO ATu E ALL- EATHER��� H LOGY P u' o REAsa r GLASS TECHNOLOGY • Maximum yields with excellent low-light • Reduction of light reflection by 50%, and temperature behaviour. plus long-term corrosion resistance due • Certified fully resistant to level 5 salt fog to high-quality • Sol-Gel roller coating processing. ENDURING HBRU PERFORMANCE • Long-term Yield Security due to Anti LIGHTWEIGHT UC1AUTY FRAME PID Technology', Hot-Spot Protect, • Stability at wind loads of up to 5400 Pa and Traceable Quality Tra.QTM. with a module weight of just 19 kg due • Long-term stability due to VDE Quality to slim frame design with high-tech alloy. Tested—the strictest test program. MAXIMUM RUST RE0UCTMNS -, n SAFE ELEcTROWS • Up to 31% lower logistics costs due to • Protection against short circuits and higher module capacity per box. t 5 thermally induced power losses due to OCELL + ytttmealc•ircwr breathable junction box and welded EXTENDEDwARRANTGES TOP BRAND PVk cables. • Investment security due to 12-year E�aa • Increased flexibility due to MC4-inter- product warranty and 25-year linear 2014 mateable connectors.the entire produc- performance warranty2. tion process from cells to modules while making Q CELLS solar modules forgery ID proof. �pp,~ ~~` Quality Tested OCEUS I P1W,rr,14011 Best polycrystalline s srv,ragy,.va,arn' solar module 2013 paaca.xeA ri+n,wMnmauao a,fR0.62215 THE IDEAL SOLUTION FOR: 154-0-0 332597 Rooftop arrays on Ground-mounted Rooftop arrays on commercial/industriaIIs solar power plants residential buildings buildings APT test conditions:Cells at-1000v against grounded,with conductive metal foil covered module surface, 25-C, 168h 2 See data sheet on rear for further information. Engineered in Germany OCELLS P + + 1 Format 65.7inx39.4inx1.38in(inc Iudirig frame) (1670 mm x 1000 mm x 35 mm) as s Weight 41.89 Ib(19.0 kg) Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass a with anti-reflection technology $ e,•a„w a a Back Cover Composite film 1 Q - a Frame Anodized aluminum - Cell 6 x 10 polycrystalline solar cells E Junction box Protection class IP67,with bypass diodes r Cable 4 mm'Solar cable;(+)>_45.67 in(1160 mm),(-)>_45.67 in(1160 mm) Connector SOLARLOK PV4,IP68 °,,,,,°„ T~�I°.3,3•,a , PERFORMANCE AT STANDARD TEST CONDITIONS(STC:1000 W/m2,25°C,AM 1.5G SPECTRUM)' NOMINAL POWER(+5W/-OW) [W] 245 250 255 260 Average Power PlaPP [W] 247.5 252.5 257.5 262.5 Short Circuit Current Icc [A] 8.52 8.71 8.90 9.09 Open Circuit Voltage Von [V] 37.15 37.49 37.83 38.18 Current at PW, I61PP [A] 8.05 8.21 8.37 8.53 Voltage at PMPP V611F [V] 30.75 30.76 30.77 30.78 Efficiency(Nominal Power) r) [%] >_14.7 >_15.0 >_15.3 >_15.6 PERFORMANCE AT NORMAL OPERATING CELL TEMPERATURE(NOCT:800 W/812,45±3'C.AM 1.5G SPECTRUM), NOMINAL POWER(+5W/-OW) [W] 245 250 255 260 Average Power PMPP [W] 182.4 186.0 189.7 193.4 Short Circuit Current ISG [A] 6.87 7.03 7.18 7.33 Open Circuit Voltage Vac [V] 34.58 34.90 35.22 35.54 Current at Pope IIdPP [A] 6.32 6.44 6.56 6.68 Voltage at PIAPP VIAPP [V] 28.86 28.89 28.92 28.94 'Measurement tolerances STC:--L3%(P,);t 10%(la,VSA,1_,V") G CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE dao too At least 97%of nominal power during � ,� __r__r__i__i__,__7--r__F__� firstyear.Thereafter max.0.6%degra- nm.,�_✓ U 100 --L--L t®G rtm•.'_ S o sstii ation per year.At least 92%of nominal power after __ __------------- 10 years. w , ,At least 83%of nominal ower after P rr -r--r-----r--ss 25 years. }w iiiiiiiso All data within measurement tolerances. ' 75 Full warranties In accordance with the ,00 xo am aoo son coo 7. sro Soo ,000 � warranty terms of the Q CELLS sales IRRADIANCE IWAn°] o s m is xo ss organisation of your respective country. YEARS The typical change in module efficiency at an irradiance of 200 W/m2 in relation to 1000 W/m'(both at 25'C and AM 1.5G spectrum)is-2%(relative), z a TEMPERATURE COEFFICIENTS(AT 1OOOW/M2,25°C,AM 1,5G SPECTRUM) Temperature Coefficient of]co a [%/K] +0.04 Temperature Coefficient of Vnn R [%/K] -0.30 Temperature Coefficient ofPn,p y [%/K] -0.42 M 0 Maximum System Voltage Vsrs [V] 1000 Safety Class I I Maximum Reverse Current Ip [A] 20 Fire Rating C Wind/Snow Load [Pal 5400 Permitted module temperature -40°C up to+85°C d (in accordance with IEC 61215) on continuous duty s 1 1 UL 1703;VDE Quality Tested;CE-compliant; IEC 61215(Ed.2);IEC 61730(Ed.l)application class A QQi',S NOTE:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use = of this product. Hanwha Q CELLS USA Corp. 8001 Irvine Center Drive,suite 1250,Irvine CA 92618,USA I Tft+1848 748 59 96 1 FAX+1 949 748 59 84 1 EMAIL q-cells-usa®q-cells.com I WED www.q-cells.us Engineered in Germany OCELLS II,I,I,I,I,II �I�ulu ^dlldldlu �u°I1 uq I�ull�l ll���� �ilil�l � �IluillQ lu��uu _r /111Pll/P((l0/Gr!70'('""�l//l@lIGD,'Ol N�WII(PLr(l(l(fRIINlIOwJAfGf.@ff�b;N,TI!hf4F;61'iCJdQfOF�ffiPfiA,v�WOfU��?fAC�6°9�((Nf(HO((mIIIQ!��l,�od'Pr�� enphase 1e+ E N E R G Y } I i - Maximum energy production The Enphase Energy Microinverter PROD J,.) C..b..0 T E - Resilient to dust, debris and shading - Performance monitoring per module System improves energy harvest, increases reliability, and dramatically System availability greater simplifies design, installation and P iw L VA P u- E than 99.8% - No single point of system failure management of solar power systems. The Enphase System includes the - Quick and simple design, installation S M A RT and management microinverter, the Envoy Communications - 24/7 monitoring and analysis Gateway, and Enlighten, Enphase's monitoring and analysis software. SAFE - Low voltage DC - Reduced fire risk C U S��j� Illlllglillllllilllll' III Ilulll IIIIIIII I� IIL IiullAlllllll IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIuVIVIVIIIIIIIII�IiIIIIIIVVIIVVII�VII' �����N� �� �� I I�, �., . �I�S�'h���,�..11 �I�IV�VIIIOIJ�I� M215 MICROINVERTER TECHNICAL ATA Recommended input power(STC) 190-260W Maximum input DC voltage 45V Peak power tracking voltage 22V-36V Operating range 16V-36V Min./Max.start voltage 26.4V/45V Max. DC short circuit current 15A Max. input current 10.5A IIIIII Maximum output power 215W 215W Nominal output current 1.OA (arms at nominal duration) 0.9A(arms at nominal duration) Nominal voltage/range 208W183-229V 240V/211-264V Nominal frequency/range 60.0/59.3-60.5 Hz 60.0/59.3-60.5 Hz Extended frequency range 60.0/59.2-60.6 Hz 60.0/59.2-60.6 Hz Power Factor >0.95 >0.95 Maximum units per 20A branch circuit 25(three phase) 17(single phase) Maximum output fault current 1.05 Arms,over 3 cycles;25.2 Apeak, 174ms duration CEC weighted efficiency 96.0% Peak inverter efficiency 96.3% Static MPPT efficiency(weighted, reference EN50530) 99.6% Dynamic MPPT efficiency(fast irradiation changes,reference EN50530) 99.3% Night time power consumption 46mW KBEmm�1IIII�IIII ��10�III�III Ambient temperature range -40°C to +651C Operating temperature range(internal) -40°C to +85°C Dimensions(WXHXD) 17.3 cm x 16.4 cm x 2.5 cm(6.8"x 6.45"x 1.0")* Weight 1.6 kg(3.5 lbs) Cooling Natural convection-No fans Enclosure environmental rating Outdoor-NEMA 6 III*lwithout mounting bracket HuiII ill IIIIIII�I III III�II�IIII�I Compatibility Pairs with most 60-cell PV modules Communication Power line Warranty 25-year limited warranty Monitoring Free lifetime monitoring via Enlighten softrware Compliance UL1741/IEEE1547, FCC Part 15 Class B CAN/CSA-C22.2 NO.0-M91,0.4-04,and 107.1-01 Enphase Energy, Inc. 142-00010 Rev02 201 1 st Street Petaluma, CA 94952 Phone: 877-797-4743 Fax:707-763-0784 irife;)@eiif)liaseeroeu,gy.t:orri d�t.d:i:a:1/ewwvv,t,a�l�)i a u�c�.coo.d.0 10 ps, I R 0 N R I D G E Roof Mou99 Solar Mounting Made Simple .ui1Yl� ,� i•I� �, .� � II w ,/i •n IR Id�. Roof MountsIronRidge Roof Mount System is a reliable,comprehensive,and feature rich the fidgliest quality and photovoltaic mounting solution.Anchored by IronRidge Standard or IronRidge fastest system r solar panel Light rails,our Roof Mount platform includes all of the components necessary • for supporting virtually any commercial or residential roof mount installation, installers. Our customers regardless of roof type or pitch. appreciate the • - • appearance found exlusively • IronRidge Standard Rails Less Material, Faster Install, Minimized Risk of Leaks Engineered far longer spans=fewer attachments&penetrations l)ther roils==(.nnqer install time and greater risk of le rrks . IronRidge Standard Rail Engineered profile allows for spans over 13' f b il Cantever can e 40/ospan p length ��ig(��r�u II( III(((j'f(jlllillff�iliq�N�allli i I��1 ��'!"'�f1� f f i1 � Attractive structural design,ideal for residential and commercial applications IronRidge Light Rail �uW Light,cost effective rail system supports 111II11111111111 �rl����1 �����I spans up to 8' rr�Ir�ii�r�fl C1�l«i I��ku pi �r i ani l;1 , r� o Cantilever can be 40/of span length Splices(internal) ) Can be installed at same location as an attachment �I Does not require additional attachments to support the splice www.ironridge.com ©Copyright 2011 IronRidge,Inc.All rights reserved. DSRFM0411_1 K����������� ,�~~�, ,,~,����~~ Roof Mounts ��wwm���o°� �' | ' � x8oxDmumSpan Chart: ]conRidge Standard Rail || |7onRIdgeU�h[RaU . � Wind Speed Snow Loads Upsf 10psf 0psf 30psf 40 psf 50 psf 60 psf Opsf 10 psf 20 psf 30psf 40 psf 90 mph 13.5' 12.5 10.5 10.0 9.0 8.5 7.5 8 7 6 5.5 S 100 mph 13.5 12.5 10.5 10.0 9.0 8.5 7.5 8 7 6 5.5 5 110 mph 13 12.5 10.5 10.0 9.0 8.5 7.5 7.6 7 6 5.5 S 120 mph 12 12 10.5 10.0 9.0 8.5 7.5 7 7 6 5.5 5 130 mph 11 11 10.5 10.0 9.0 8.5 7.5 6.5 6.5 6 5.5 S 140 mph 10 10 10 9.5 9.0 8.5 7.5 6 6 6 5.5 S 150 mph 9.6 9.5 9.5 9.5 8.5 8 7.5 5.5 5.5 5.5 5.5 S Roof Zone 1Flush Mount Only Building mean roof height=3O' *Formoreinfbnnabonvisit www.iron hdDecomto Slope=G"/ft. C|eamncebetween roof and raU:2" download cerb0codon |e�ecsin�aUa�on'guides, Exposure category 8 End Cant Span:4U%(acU.interior span) and touse our roof mount configumDonsoftware. Module length:77" Middle 1/3 span rail splice not permitted � Attachments Clamps Adjustable Lfeet(4pack kits) Panel Sizes 1.2Z"toZ.3U" � Adjustable tilt leg kits(5"tu45^) Mid clamps(require only � Flush mount aluminum standoffs 1/4"between panels) - (3",4-16",7") Mid clamps available in hex Tilt steel standoffs (4'6") ort-bolt - All hardware stainless steel End Caps Protect against debris while Wire Clips providing finished look for Accommodate up to eight6mm panel both standard and light mai|s winesoran Enphaaevvire harness _~ � � Experience-Designing/manufacturing On-line Resources Available: solar mounting products since l996 Video Tutorials � Single Source-Roof mounts,ballasted Product Configurators mounts,large arrays,and more; o Product Certifications solution for your sperificapplication Installation Guides Cu��omerSa�sfac�on-Customer Data Sheets ---- sem � service and Reseller Locator you succeed Sales: 800-227'9523 wwvx|nonRidge.com so|es@ironridge.com l435Bmoohte| Road Willits,CA9S48O