Loading...
HomeMy WebLinkAboutOnsite wastewater system construction notes - Consultant Review - 37 WELLINGTON WAY 8/8/2019 • North Andover Health Department Community and Economic Development Division ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES LOCATION INFORMATION ADDRESS: 37 Wellington Way (Lot 6) MAP:105C LOT: 22 INSTALLER: David Maynard — Maynard Construction DESIGNER: Christiansen & Sergi, Inc PLAN DATE: 5/20/16 REV 12/22/16 BOH APPROVAL DATE ON PLAN: 1/11/2017 INSPECTIONS TANK INSPECTION: 6/8/2017 DATE OF BED BOTTOM INSPECTION:6/13/2017 DATE OF FINAL CONSTRUCTION INSPECTION: 6/20/17 DATE OF FINAL GRADE INSPECTION: SITE CONDITIONS ❑ Contractor reports any changes to design plan ❑ Existing septic tank properly abandoned- ® Internal plumbing all to one building sewer ® Topography not appreciably altered Comments: SEPTIC TANK ® Building sewer in continuous grade, on compacted firm base ❑ Cleanouts per plan ® Bottom of tank hole has 6" stone base ® Weep hole plugged ® 1500 gallon tank has been installed H-10 loading ® Monolithic tank construction ® Water tightness of tank has been achieved by visual testing ® Inlet tee installed, centered under access port ® Outlet tee installed, centered under access port (gas baffle) ❑ inch cover to within 6" of finish grade installed over one access port ® Boots around inlet & outlet Comments: 6/13/17 Tank was 16' from the house — Michele Grant DISTRIBUTION-BOX ❑ Installed on stable stone base ® H-20 D-Box ❑ Inlet tee (if pumped or>0.08'/foot) ® Hydraulic cement around inlet & outlets ® Observed even distribution ❑ Speed levelers provided (not required) ® Schedule 40 PVC Pipe Comments: SOIL ABSORPTION SYSTEM (General) ® Bottom of SAS excavated down to C soil layer, as provided on plan ® Size of SAS excavated as per plan ® Title 5 sand installed, if specified on plan ❑ 40 Mil HDPE barrier installed ® Laterals installed ® Elevations of laterals and chambers installed as on approved plan ❑ Retaining wall (boulder/concrete /timber/ block) ❑ Final cover as per plan Comments: 6/13/2017 The Bottom of the Bed was approximately 15' down to the "C" layer 55' width x 29 ' length — Michele Grant FINAL GRADE ❑ l Loamed ❑ Seeded . ❑ Cover per plan C 0,1 0001 Comments: DOCUMENTS NEEDED �1el ❑ Certification of Installation Form submitted By engineer and signed and dated by Engineer and installer [� As-Built Plan i i i i i BM = 128.42 H R = 9.30 HI = 137.72 SYSTEM ELEVATIONS ROD AS-BLT INVERT DESIGN INVERT ELEVATION ELEV ELEV Benchmark Building Sewer OUT 3.70 133.69 133.05 Septic Tank IN 4.59 132.80 132.72 Septic Tank OUT 4.76 132.63 132.47 Pump Chamber IN Pump Chamber OUT Distribution Box IN 5.18 132.21 132.22 j Distribution Box OUT 5.35 132.04 132.05 Lateral 1 Beg 5.38 132.01 131.95 Lateral 1 End 5.64 131.75 131.75 j Lateral 2 Beg 5.40 131.99 131.95 j Lateral 2 End 5.64 131.75 131.75 Lateral 3 Beg 5.43 131.96 131.95 Lateral 3 End 5.64 131.75 131.75 j I Bottom of Bed/Chamber 7.46 130.26 SKETCH PLAN CRITICAL SETBACK DISTANCES Mark those distances checked in the field against the design plan and regulatory setback Tank SAS Sewer ® Property line 10 10 -- ® Cellar wall 10 20 -- ® Inground pool 10 20 -- ® Slab foundation 10 10 -- ® Deck, on footings, etc 5 10 -- Waterline 10 10 10' ® Private drinking well 75 1002 50 ® Irrigation well 75 100 ® Surface Water 25 50 ® Bordering Vegetated Wetland j Salt Marsh,Inland/Coastal Bank' 75 100 ® Wetlands bordering surface water supply or trib. (in Watershed) 150 150 ® Trib. to surface water supply 325 325 ® Public well 400 400 ® Interim Wellhead Prot. Area ® Reservoirs 400 400 ® Drains (wat. supply/trib.) 50 100 ® Drains (intercept g.w.) 25 50 ® Drains (Other)Foundation 10(5) 20(10) ® Drywells 20 25 i I Suction line 222(2) 2 100 feet is a minimum acceptable distance and no variance is allowed for a lesser distance(NA 5.02). 3 As defined in 310 CMR 10.55, 10.32, 10.54,and 10.30,respectively,pursuant to 15.211(3),also by NA wetland bylaws i 6/29/20V, Town of North Andover Mail-Lot 6#t37 Wellington Way 4 NaR BAN OVER Massachuserbis, .__ Michele Grant<mgrant@northandoverma.gov> Lot 6 #37 Wellington Way 1 message Marylee Messina <messinanewhomes@gmail.com> Thu, Jun 29, 2017 at 10:15 AM To: Michele Grant <Mgrant@northandoverma.gov> Hi Michele, Bob asked me to email you to let you know that Messina Development Co., Inc. will be responsible for the final grading and seeding over the septic system at lot 6 #37 Wellington Way. If you need additional information, please let me know. Thanks, Marylee Pyo i https://mai 1.google.com/mai I/ca/u/O/?ui=2&ik=d4458df3d9&jsver=l EZPUTRTBd.en.&view=pt&search=inbox&th=15cf4352a6d1 ccl8&si ml=15cf4352a6d1 cc18 1/1 PUBLIC HEALTH DEPARTMENT (ommunity&Economic Development TOWN OF NORTH ANDOVER SEPTIC DISPOSAL SYSTEM—INSTALLATION CERTIFICATION The undersigned hereby certify that the Sewage Disposal System(constructed;( )repaired; By: (Print Na Located at: a (Installation dress) Was installed in conformance with the North Andover Board of Health approved plan,originally dated and last revised on /;2 z Z — /lp ,with a design flow of L/ y V gallons per day. The materials used were in conformance with those specified on the approved plan;the system was installed in accordance with the provisions of 310. CMR 15.000,Title 5 and local regulations,and the final grading agrees substantially with the approved plan.All work is accurately represented on the As-built which has been submitted to the Board of Health. Bottom of Bed Inspection Date: Engineer Representative(Signature) i i And—Print Name Final Construction Inspection Date: Engineer Representative(Signature) I And—Print Name Installer: (Signature) Date: And—Print Name Engineer: (Signature) Date: And—Print Name 120 Main Street, North Andover, Massachusetts 01845 Phone 978.688.9540 Fax 978.688.9542 Web http://www.northandoverma.gov