Loading...
HomeMy WebLinkAboutDEP - Approval of General Use - Correspondence - 487 WINTER STREET 8/30/2019 Commonwealth of Massachusetts Executive Office of Energy&Environmental Affairs —---—-------.............................--........................... .................... Department of Environmental Protection One Winter Street Boston, MA 02108-617-292-5500 Charles D.Baker Matthew A.Beaton Governor Secretary Karyn E.Polito Martin Suuberg Lieutenant Governor Commissioner APPROVAL FOR GENERAL USE Pursuant to Title 5, 310 CMR 15.000 RECEIVED Name and Address of Applicant: VER Infiltrator Water Technologies,LLC. or "0", , ,t�NooT P.O.Box 768 VAEPOb IdIX'i'j�wE 6 Business Park Road Old Saybrook,CT 06475 Trade name of technology and model: High Capacity chamber, High Capacity H-20 chamber, Quick4 High Capacity chamber, Quick4 High Capacity HD chamber, Quick4 Plus High Capacity chamber (fl- inch invert), Quick4 Plus High Capacity chamber (13-inch invert), Standard chamber, Quick4 Standard chamber, Quick4 Standard HD chamber, Quick4 Plus Standard chamber (5.3-inch invert), Quick4 Plus Standard chamber (8.0-inch invert), Quick4 Plus Standard LP (Low Profile) chamber (3.3-inch invert), Quick4 Plus Standard LP (Low Profile) chamber (8-inch invert), Infiltrator 3050 (Storm Tech SC-740) chamber,Equalizer 24 chamber, Quick4 Equalizer 24 chamber,Equalizer 36 chamber, Quick4 Equalizer 36 chamber,Quick4 Equalizer 24 LP(Low Profile) chamber(6 inch invert),and Quick4 Equalizer 24 LP (Low Profile) chamber(2 inch invert) (hereinafter the"System!'). Schematic drawings of the System and a design and installation manual are a part of this Certification. This approval allows the installation of the above identified chambers without aggregate. Transmittal Number: X259183 Date of Revision: February 19,2015,modified June 12,2015 Authority for Issuance Pursuant to Title 5 of the State Environmental Code, 310 CMR 15.000,the Department of Environmental Protection hereby issues this Certification to: Infiltrator Water Technologies, LLC., P.O. Box 768, 6 Business Park Road, Old Saybrook, CT 06475 (hereinafter "the Company"), for General Use of the System described herein. The sale, design, installation, and use of the System are conditioned on compliance by the Company, the Designer, the Installer and the System Owner with the terms and conditions set forth below. Any noncompliance with the terms or conditions of this Approval constitutes a violation of 310 CMR 15.000. June 12,2015 David Ferris,Director Date Wastewater Management Program Buren Li of Water Resources This informah iF,available in alternate format.Call Michelle Waters-Ekanem,Diversity Director,at 617-292-5751,TTY#Mass Relay Service 1-800-439-2370 MassDEP Website:www.mass.gov/dep Printed on Recycled Paper Infiltratoi ' amber,Infiltrator Water Technologies. Page 2 of 6 Approval G eneral Use—June 12,2015 I. Design Standards The models listed in Table 1 are covered under this Certification. Table 1: Chamber Dimensions Dimensions Invert Model W x L x H Height Inches Inches Equalizer 24 15 x 100 x 11 6 Quick4 Equalizer 24 16 x 48 x 11 6 Quick4 Equalizer 24 LP (6-inch invert) 16 x 48 x 8 62 Quick4 Equalizer 24 LP (2-inch invert) 16 x 48 x 8 2 Equalizer 36 22 x 100 x 13.5 6 Quick4 Equalizer 36 22 x 48 x 12 6 Standard Chamber 34 x 75 x 12 6.5 Quick4 Standard 34 x 48 x 12 8 Quick4 Standard HD 34 x 48 x 12 8 Quick4 Plus Standard(5.3-inch invert) 34 x 48 x 12 5.3 Quick4 Plus Standard(8-inch invert) 34 x 48 x 12 8 Quick4 Plus Standard LP (3.3-inch invert) 34 x 48 x 8 3.3 Quick4 Plus Standard LP (8-inch invert) 34 x 48 x 8 83 Infiltrator 3050 or StormTech SC-740 51 x 85.4 x 30 22.254 :' High Capacity Chamber 34 x 75 x 16 11 High Capacity H-20'Chamber 34 x 75 x 16 11 Quick4 High Capacity 34 x 48 x 16 11.5 i Quick4 High Ca acity HD 34 x 48 x 16 11.5 Quick4 Plus High Capacity(8-inch invert) 34 x 48 x 14 8 Quick4 Plus IIigh Capacity(13-inch invert) 34 x 48 x 14 135 ' This approval allows the use of the high capacity H-20 chambers but makes no determination as to the dhambers meeting the H-20 loading requirements. 2 Includes 'riftltrator MultiportTM invert adapter attached to the side of the end cap. 3 Include, 'uick4 Plus Periscope adapter attached to the top of the Quick4 Plus All-in-One 8 Endcap. 4 Only sysscins installed with this invert height shall be allowed to use the effective leaching area asp fated with this model in Table 2. 5 Incluu. `uick4 Plus Periscope adapter attached to the top of the Quick4 Plus All-in-One 12 Endca 2. The Systciu is an open-bottom leaching unit molded from polyolefin resin. It can be installe,' without aggregate or distribution pipe as an absorption trench or as a bed or fif-' If the System is installed with stone aggregate then the "Effective Leaching ea" in Tables 2 and 3 is not applicable, and must be designed in accordant vith the provisions of 310 CMR 15.000. Infiltrator Chambc Anfiltrator'd: r Technologies. Page 3 of 6 Approval for Gen, al Use—Jun '_,2015 3. The total i Cfective leaching area for any Chamber Model shall be calculated by multiplyin the Effective Leaching Area per square foot of chamber times the total lengtl of chamber from end cap to end cap including end caps. 4. For new cc istruction or upgrades,the applicant can size the System in a trench configurati n,using the effective leaching areas presented in Table 2. "Cable 2: Effective Leaching Area in Trench Configuration for New Construction and Remedial Sites' Effective Effective Model Leaching' Leaching Area Area SF/LF SF/LF E ua', :r 24 3.76 N/A Quic' Equalizer 24 3.90 N/A Quic - Equalizer 24 LP (6-inch invert) 3.90 N/A Quic Equalizer 24 LP (2-inch invert) 2.78 N/A Equ,-1 -r 36 4.73 N/A Quick Equalizer 36 4.73 N/A Stanch d Chamber 6.53 N/A Quick, Standard 6.96 N/A Quick- Standard HD 6.96 N/A Quic Aus Standard(5.3-inch invert) 6.20 N/A Quic Plus Standard(8-inch invert) 6.96 N/A Quip Plus Standard LP (3.3-inch invert) 5.65 N/A Quic Plus Standard LP (8-inch invert) 6.96 N/A Inf,' ,r 3050 or StormTech SC-740 N/A 6.71 Higl .pacity Chamber 7.79 N/A !�Higl, pacity H-20' Chamber' 7.79 N/A QQuuicc. i4igh Capacity 7.93 N/A i Quic ligh Capacity HD 7.93 N/A Qui. lus High Capacity(8-inch invert) 6.96 N/A is 'lus High Capacity(13-inch invert) 7.93 N/A '.l ffecti.t pril 21,2006,310 CMR 15.251(1)(b)maximum trench width is 3 feet. '.Ff"octi, 'iching area is equal to 1.67(bottom width+(2x invert height))for Systems 3 feet e s in width. $.liffecti, 'Iching area is equal to 1.0(3 +(2x invert Height)) for Systems with a width greater 3 feet. 9.The m� -, rn trench width allowed to calculate effective leaching area is 3 feet. 5. Sy�t", -r IIed on remedial sites shall be allowed to utilize the effective le: presented in Tables 2 or 3, or additional reductions in soil ab "? ...tein may be allowed. In no instance shall the reduction in the soil ab-orpt; :stem required in 310 CMR 15.242 exceed the maximum reduction all dternative systems approved in accordance with 310 CMR 15.284. Infiltrator Chamber. :ifiltr hnologies. Page 4 of 6 Approval for General Use 6. For r c action or an upgrade, the applicant can size the System in bed or field o air ion, using the effective leaching areas presented in Table 3. 4ective Leaching Area for Bed or Field Configuration New Construction and Remedial Sites Effective Model Leaching10 Area SF/LF I _ 2.09 i 4 lizer 24 2.23 ( -ner 24 LP (6-inch invert) 2.23 Q lizer 24 LP (2-inch invert) 2.23 F, 3.06 Q izer 36 3.06 S' inber 4.73 Q d and 4.73 C is ird HD 4.73 °sndard(5.3-inch invert) 4.73 'mdard(8-inch invert) 4.73 C adard LP (3.3-inch invert) 4.73 Q ,ndard LP (8-inch invert) 4.73 :: or StormTech SC-740 7.10 _B chamber 4.73 L i4-20' Chamber 4.73 apacity 4.73 _� ipacity HD 4.73 ;h Capacity(8-inch invert) 4.73 i Capacity(13-inch invert) 4.73 10. El g area is equal to 1.67 times bottom width only. 7. ti C ; used with a secondary treatment unit approved in accordance g4 or 15.288, additional reductions in soil absorption system 1. y° these situations the reduction in the SAS cannot exceed the n X= under the secondary treatment units approval. In no instance sl I a the soil absorption system area required in 310 CMR 15.242 e. ii reduction allowed for alternative systems approved in acc. CMR 15.284. II. Special ( >> 1. -pproved Alternative Chamber for use as an Alternative Soil ). In addition to the Special Conditions contained in this n .; n shall comply with the"Standard Conditions for Alternative "Ise Certification and/or Approved for Remedial Use" (the Infiltrator Chamber, I Iti logies. Page 5 of 6 Approval for Genen se I ai ,ns'), except where stated otherwise in these Special C n( . 2. T w ion This Certification is for the installation of a System to serve n .v( , )n or an existing facility with a proposed increase in flow, for v ic" !1: ttion in compliance with 310 CMR 15.000 has been approved b, tb Authority and the site meets the siting requirements for new ct is' : )vided in Paragraph 6 in section II Design and Installation E ZZ ie Standard Conditions. 3. R m s General Use Certification also applies to the installation of a S it( 1 .1 :jade or replacement of an existing failed or nonconforming s_ tc . r� A that the facility meets the siting requirements for upgrades, as p w! _ag aph 7 in section 11 Design and Installation Requirements of the .n( i( .is 4. e exempt from the minimum inlet spacing requirements of 310 C 1F 5. ave a minimum of one inspection port through the top of one o tb "'he inspection port shall be capped with a screw type cap and a: :e a three inches of finish grade. 6. `' ie t in is installed in trench configuration,then the system shall c n1 _, requirements: a L ench) 100 feet maximum(310 CMR 15.251(1)(a)); b V nch) 2 feet minimum to 3 feet maximum(310 CMR - Chambers greater than 3 feet wide, when specifically abject to other Special Conditions and limitations; C ,eparation distance between any two trenches shall be two t Live width or depth of each trench, whichever is greater, or between trenches is designated as reserve area, three times the e w or depth of each trench,whichever is greater(310 CMR 1. d T "aching area shall be calculated using the bottom area and a vO feet(per side) of side wall area for each trench(310 CMR 1 he situated, where possible,with their long dimension the slope of the natural soil. Where possible they shall follow Is (310 CMR 15.251(2)); :«tcd at different elevations shall be designed to prevent ie higher trench(es)flowing into the lower trench(es) (310 f 1); en trenches may be designated as system reserve area only ration distance between the excavation sidewalls of the primary r _,ast three times the effective width or depth of each trench, -eater(310 CMR 15.251(4)) -Chambers greater than 3 feet Infiltrator Chamber. ! logi Page 6 of 6 Approval for General cifically approved, shall be separated by three times the actual abject to other Special Conditions and limitations; and h el ution lines exceeding 50 feet in length shall be connected and n; A in accordance with 310 CMR 15.241 (310 CMR 7. VV, rench configuration, approved Alternative Chambers greater tl a; d with a minimum separation distance between any two th cs the actual width of the chamber, or where the area �s is designated as reserve area,three times the actual width of 11 id b C ttitled to a maximum effective width of 3 feet for the purposes otal effective leaching area. 8. `a 1 be l or field configuration,the System may be installed t pi;)ing,but must comply with the following requirements in 3 a; ling beds or fields is restricted to systems with a calculated less than 5,000 gpd per leaching bed or field(310 CMR L b' a enL th of chambers in series shall be 100 feet(310 CMR c :nc.• between adjacent beds/fields shall be ten feet(310 CMR lid d ich i ug area shall include only the bottom area, not the C. .Z 15.252(2)(1)). 9. F( ! ucted in fill and installed,the System shall be installed as sl i :iR 15.255 Construction in Fill,except the minimum 15 foot h- ? .)n c'.istance to be provided between the soil absorption area and th opc shall be measured horizontally from the top of the cl 10. T npt from 310 CMR 15.287, specifically items: (5)requiring w - i of alternative system prior to property transfer, (6)need for a cc '9) need for an operation and maintenance contract with an of ?eeci notice requirement.