Loading...
HomeMy WebLinkAboutDry Chemical System Reports - Correspondence - 1/26/2019 Easte p (Fin? (Prot c i n, f,Lc Pre-Engineered Dry Chemical System Report Date of service: Time: PM flkonsocket, (RI 89. w Annual *Semi-Annual Cl Recharge Cl Installation C1 Renovation Cl Arnerex Cl Ansul 0 Badger ` ].Kidde I"7 Pem-All CI Pyro•Chem 0 Other 1 Customer/location Total flooding system 171 local application system Single ouiale""tTriple Cl Other Name' �� i 1 - � D � � 1 � .r,� �fir.� ��:� �i �"�t -�_ � Mod _— Address: f f �. i el#and type: ^ " 1 ` City/St/Zip. �,. 0 Connected reserve - - - - 'Phone` ._.... t ....__�_ - �� � location of system: Owner or y. Area rotected:Manager: w„. . r, A... Yes No N/A Yes No N/A 1 System interlocked with building fire alarm _ , C1 � 18 Checked operation of manual release O U 2 System discharged,evidence of tampering _ &� �C1� C1 � 20 Checked operation of micro-switch delay..... ',� C1 Cl operation - u 3 All seals Intact. P. g P .. _icra switch -- _- _i71.,..�.. _. 4 Hazard properly covered w/correct nozzles Cl p 21 Checked operation of gas valve. Sae _ 5 Checked Positioning of all nozzles 1 O Cl CT Mechanical C1 Electrical C1 C 1 P� 6 Pressure as 22 Checked operation of shutdowns C) C1 e in proper range . 23 Checked reserve aver P P _.. ✓� 7 Checked rtrgldgewei weight Last Test NI 0 e 24 Pi i P _--- g. 8 Checked PneumaticCC] CJ png/conduit securely bracketed C1 Cl 4(� Cl C1 70 Inspect cylinder Date � "' YearMaint. 2S NozzlesclearnedandPr1.opercaps/coversinPlace C linderh drostatic est C1 O Cl 26 System cartridge&sealsreplaced/safety pins removed Q Cl Cl P. y _ _ _ 11 operated system from terminal link `° CJ 27 System operational and awned C © C7 12 Checked operation of electric detection 28 Proper fire extinguisherforotherareas �� Cl C1 �.,,, y13 Checked travel of cable and link position _ � . C) r'I i 29 Fire extinguishers properly serviced, _ 4 Fusible links,quantity of each — — - i 30 Personnel instructed on automatic operation of system C7 C1 7.1 � 280 212° tructed on manual 135°....... ... 165°-...._- .� ._..._ _„;�_ .... 31 Personnel insmanthlyinspections perfo�rrnedrf system C1 . e system 0 0 Cl 32 Were 360° 450° 504° other. _..- 33 Was fireextingni slier training provided? Cl 1 C7 15 Thermal detectors,quantity of each 34 Service and certification tag on system t Cl C1 35 System ercurrentUL1254 ." 225° 325° 450°___...._.. 60D°_.........._.._ j y P standard and meets manu facturer's UL listing C) CI 16 Replaced fusible links Mfg. data,- , �� d"�" 36 Pla - nsofori inal system minstallationonsite CT - 17 Checkedand cleaned fusible inks CC1 1 C1 . Nate:Non-winpliant systems might fail to extinguish/suppress a fire. COMMENTS/NON-COMPLIANCE qq1 P i cF /Ary/ L ,, Technician' " < Gate Time Costonlo,r's Aythorizecl Agent WHITE-(USTOMER COPY YELLOW-DISTRIBUTOR PINK-AUTHORITY HAVING JURISDICTION REORDER HUSER PART#SER300 ' C) Heiser Logistics e astent g Pre-Engr�eered Dry Chemical System Report ',ire Protection L., AM, T� t &1nd', - Vn Date of service: � ' �, "`� Time: PM c f �" .. ° �,� 'T�'��,"o �;" ' , ���.w�a, � �� annu„nl Cl Simi-Annuai © Recharge O installation C3 Renovation " 0 --_ 4 n Ainerex 0ansul .....__ O badger `Kidde C1 Pem-all C1 Pyro-Chem ©Other __--- (ustomer/location 0 Total flooding system O local application system � Sin Name:' i_�, ..i. �._.__ O Single 0 Doubl e hTripie Cl Other Yp Address: Model#and t e City/St/Zip .A a8 i , k'u �w .N Cl Connected reserve _ w i __..... _...... ._ _. .__ Yi ° w _.. .....° _ 1 ... ,d Phone: Location a system: � t wneror a � Mana er: —(�° _.. " area roteeted: i r' g p. -- ._ _.._.... .. _ Yes No N/A Yes No N/A 1 Sy stem interlockedwikhbuildingfirealarm �d0 O C) 18 Checked operation of manual release 2 Sy stem discharged _ _ _C3 C1 19 Checkedaperetionoftimedelay C1 Cl.. ::. 3„Ali seiwis Intact.No evidence oftamperin� €�3 C1 © 20 Checked operation of micro switch C1 C11. C.l _ .... _........- ,. 4 Hazard properly covered w/correct nozzles _ ) O O 21 Checked operation of gas valve.Size: 1.5 Checked positioning of all nozzles 0 Mechanical 0 Electrical _ C1 C3 22 Checked operation of shut downs CI CJ 6 Pressure gauge inproperrane�ew C�3 O C1 _ _ 23 Checked reserve power suP.P�Y_._._. 7 Checkedcartridgeweight Last Test Repl ..... ._C3 n... l — 8 CheckedPneumaticact 24 Piping/conduit securely bracketed 01 C] CJ 9 C linderh dro actuator © Cl . static Test Date '" � 6Year Maint 25 Nozzles leaned and proper capskavers mglace O Y Y ' . _ 26 Systemcartridge&seals replaced/safety.Pins removed O ®._ 10 Insp, ttcyligderandmount _ _ r .....-0 11 0 erated s st.p_ y em from termmallink _ { © � � 27 5ystemoperatianalandarmed - - 28 Proper fire extinguisher for other areas , C7 C1 12 Checked operation ofelectricdetection O 03 i - 13 Checke0ravelof(able and link .. _ position ©� Cl 29 Fire extinguishers properly serviced30 C7 Personnel instructed on aut a c o eration of system Personnel instructed on manual operational _. 14 Fusible links,quantity of each omti system C.3 C1 CJ p al of system C C1 CT 135° 165° 2124 t — 33 Wasfiresextin uishelrtra n 32 Were etio�Opedrefd;Omed1 - C1 T5 360° 450° 500° other- - - _.g . . ....._......... ._.g..P_ 15 Thermal detectors,quantity of each 34 Service and certification tag on system C) n 2250 _.____.. 325° 450° . 600° 35 System installed per current UL 1254 standard and meets manufacturer's UL listing _4 16 Replaced fusible(inks Mfg date _._ - 17 Checked and cleaned fusible inks 36 Plansoforiginalsysteminstallationonsite C -- _ .....__ C7 L""l-....... Nate:Nan-Compliant systems might fail to extinguish/suppress afire. COMMENTS/NON-COMPLIANCE i _. .. ........ . _... . _. - --- _ __..._.._ ......._.... _-_.._ ... . .._.._.. -- ._ ... ._.. -- ---.... ...__... ..... rN p "Tech � nician -�'� I�at�"�' Time Customer's Atathartz'edAgerat WHITE-CUSTOMER(OPY YELLOW-DISTRIBUTOR �' PINK-AUTHORITY HAVING JURISDICTION REORDER HnsER PART#SER300 0 Heiser Logistics