HomeMy WebLinkAboutANSUL System Inspection Report - Correspondence - 757 TURNPIKE STREET 8/1/2019 Report of Inspection/Test Semiannual NFPA 9617117A IMPACT 08101/2019 Property Conducted by: Robert Senesi FIRE STOP&SHOP#92 RI JFE-221 26 Hampshfre Drive.Hudson,NH 0051 110073 MA CC-005662 (603)29a-7531 281 Books Street,Norcesler,MA 018436 Building#:312311 (503)852-7227 767 TURNPIKE STREET +A"NN.GETFIREPROTECTION COM NORTH ANDOVER MA 01845 STORE MANAGER 978-683-9666 Reference Number: 16883590 Report of Inspection/Test for Asset.=ANSU L R102 6G Kitchen Hood Information Manufacturer ANSUL Model R102 Cylinder Size Master 3 GAL Cylinder Size Slave 3 GAL Serial Number dt 2010 Last Hydro 2001X2 Number of Links 4 Appliance Protected ROTISSERIE, FRYER Location of Shut Off 2"ansul Location of Pull Station entrance door above ceiling Fuse Link 360 F Fuel Shut Off Electric True Fuel Shut Off Gas True Type Wet Protected Applicances from Left to Right Appliance 1 Fryer Appliance 2 Rotisserie QUESTIONS All appliances properly covered wlcorrect nozzle? Yes Duct and plenum covered wlcorrect nozzles? Yes Check positioning of all nozzles. Yes System installed in accordance w1MFG UL listing? Yes is Haodlduck penetrations sealed wlweld or UL device? Yes Check if seals intact,evidence of tampering Yes Pressure gauge In proper range(If gauged)? NIA Check cartridge weight(If applicable) Yes k Inspect cylinder and mount Yes Operate system from terminal link Yes Test for proper operation from remote Yes Check operation of gas valve Yes i Are the proper nozzle covers in place? Yes Replaced fuse links with new calendar year links? Yes Check travel of cable nutslS-hooks Yes Piping&conduit securely bracketed? Yes Exhaust fan in operating order? Yes Fuel shut-off in on position? Yes Manual&remote set/seals in place? Yes Replace systems covers Yes System operatlanai&seals in place? Yes Slave system operational? Yes Personnel instructed in manual operation of system? Yes Service&Certification tag on system? Yes Is this system U.L.300 compliant? Yes Does the makeup air shut down? Yes System interlocked with building fire alarm? Yes Manual Release Unobstructed? Yes Proper separation between fryers and flame? Yes Fan warning sign on hood? Yes Copyright 2019 Inspect Point Pagel of 6 Report of Inspection/Test Sernlannual NFPA 9617117A - IMPACT 08l0112019 Property Conducted by: Robert SenesiFIRE STOP&SHOP#92 RI JFE-221 26 Hampshire Odve,Hudson.HH 03051 110073 MA CC-005662 (603)2937531 tot brooks SL—t,W.a"Ster,IJA01606 Building#:312311 h'MN.GETF I(T5PR ROT � 1R F R E0TE E CT i 0 N.COFA 767 TURNPIKE STREET NORTH ANDOVER MA 01845 STORE MANAGER 978-683-9666 Reference Number: 16883590 K class fire extinguisher in rocking area? Yes Proper Qly and type of fire extinguishers at location? Yes Fire extinguishers properly inspected and serviced? Yes Fire extinguishers last serviced By and date. impact3119 Suppression system is compliant? Yes Hood grease buildup? Normal Flood last cleaned date. 1118 I. Page 2 of 6 Copyright 2019 Inspect Point