Loading...
HomeMy WebLinkAboutPass - Title V Inspection Report - 6 PENNI LANE 11/14/2019 c Commonwealth of Massachusetts Title 5 Official Inspection Form sments - le Subsurface Sewage Disposal System Form Not for Voluntary Asses 6 Penni Lane — Property Address Tierney___ - - —— --- ---- --- --- ------ Owner Owner's Name information is North Andover — MA 01845 — November 6, 2019 — required for every _ — — State Zip Code Date of Inspection page. City/Town-- Inspection results must be submitted on this form. Inspection forms may not be altered in any way. Please see completeness checklist at the end of the form. S�9 Important:When 4 2019 filling out forms A. Inspector Information NOV 1 fll on the computer, H ANDO Dean_G. Luscomb II — — —-- useonlythetab --- -- __ _.— ------- -- — •:OV� .�DE�P�iog — key to move your Name of Inspector _— cursor-do not Dean G. Luscomb 11 & Sons use the return Company Name key. 288 Maple Street--— --- ---_--------- -- -- — ---- rah Company Address MA— — — - --- 01949 --__— _Middleton — —_ Citylrown — — Sta—te Zip Code 978-774-4065 — -- --- S1848_ Telephone Number — License Number B. Certification I certify that: I am a DEP approved system inspector in full compliance with Section 15.340 of Title 5 (310 CMR 15.000); 1 have personally inspected the sewage disposal system at the property address listed above; the information reported below is true, accurate and complete as of the time of my inspection; and the inspection was performed based on my training and experience in the proper function and maintenance of on-site sewage disposal systems. After conducting this inspection I have determined that the system: 1. ® Passes 2. ❑ Conditionally Passes 3. ❑ Needs Further Evaluation by the Local Approving Authority 4. ❑ Fails 77 November 6, 2019 -- Inspector's Signature Date The system inspector shall submit a copy of this inspection report to the Approving Authority (Board of Health or DEP)within 30 days of completing this inspection. If the system has a design flow of 10,000 gpd or greater, the inspector and the system owner shall submit the report to the appropriate regional office of the DEP. The original form should be sent to the system owner and copies sent to the buyer, if applicable, and the approving authority. Please note:This report only describes conditions at the time of inspection and under the conditions of use at that time.This inspection does not address how the system will perform in the future under the same or different conditions of use. Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 1 of 18 t5insp.doc•rev 7/26/2018 Commonwealth of Massachusetts Title 5 Official Inspection Form I" �� Subsurface Sewage Disposal System Form -Not for Voluntary Assessments l 6 Penni Lane---- — — — ------ ------ -- vV� Property Address _Tierney __ __ - - — -- ---- — --- Owner Owner's Name information is N MA 01845 November 6, 2019 North Andover required for every -- --- -- --- State Zip Code Date of Inspection page. City/Town C. Inspection Summary Inspection Summary: Complete 1, 2, 3, or 5 and all of 4 and 6. 1) System Passes: ® I have not found any information which indicates that any of the failure criteria described in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below. Comments: 2) System Conditionally Passes: ❑ One or more system components as described in the"Conditional Pass" section need to be replaced or repaired. The system, upon completion of the replacement or repair, as approved by the Board of Health, will pass. Check the box for"yes", "no" or"not determined" (Y, N, ND) for the following statements. If"not determined," please explain. r� V The septic tank is metal and over 20 years old* or the septic tank(whether metal or not) is structurally j unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass inspection if the existing tank is replaced with a complying septic tank as approved by the Board of Health. *A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of Compliance indicating that the tank is less than 20 years old is available. ❑ Y ❑ N ❑ ND (Explain below): Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 2 of 18 t5insp.doc•rev.7/26/2018 Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form Not for Voluntary Assessments i 6 Penni Lane P — -- -- — --- --— — --- — -- -- r operty Address Tierne _ -- Owner Owner's Name information is MA 01845 _ _Nove_mber 6, 2019— required for every North Andover—_ ___— --- - —— page. CitylTown State Zip Code Date of Inspection C. Inspection Summary (cont.) 2) System Conditionally Passes (cont.): ❑ Pump Chamber pumps/alarms not operational. System will pass with Board of Health approval if pumps/alarms are repaired. ❑ Observation of sewage backup or break out or high static water level in the distribution box due n \� to broken or obstructed pipe(s) or due to a broken, settled or uneven distribution box. System will Iv pass inspection if(with approval of Board of Health): " ❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ ❑ N ❑ ND (Explain below): obstruction is removed Y❑ ❑ distribution box is leveled or replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The system will pass inspection if(with approval of the Board of Health): ❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below): ❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below): V -- / 3) Further Evaluation is Required by the Board of Health: ❑ Conditions exist which require further evaluation by the Board of Health in order to determine if the system is failing to protect public health, safety or the environment. a. System will pass unless Board of Health determines in accordance with 310 CMR 15.303(1)(b)that the system is not functioning in a manner which will protect public health, safety and the environment: Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 3 of 18 t5insp.doc•rev.7/26/2018 commonwealth of Massachusetts Title 5 official Inspection Form Subsurface Sewage Disposal System Form Not Voluntary 6 Penni Lane --------- —-- ---------- --- u� Property Address Tierney Owner Owner's Name information is MA 01845_— November 6, 2019 — required for every North Andover _ — -- — —— — City/Town State Zip Code page. Date of Inspection C. Inspection Summary (cont.) ❑ Cesspool or privy is within 50 feet of a surface water ❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh b. System will fail unless the Board of Health (and Public Water Supplier, if any) determines that the system is functioning in a manner that protects the public health, safety and environment: ❑ The system has a septic tank and soil absorption system (SAS) and the SAS is within 100 feet of a surface water supply or tributary to a surface water supply. ❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water supply. ❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well. ❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a private water supply well". Method used to determine distance: _ _--—_—_----- — * This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form. c. Other: 4) System Failure Criteria Applicable to All Systems: You must indicate"Yes" or"No" to each of the following for all inspections: Yes No �f Backup of sewage into facility or system component due to overloaded or ❑ ® clogged SAS or cesspool t to the surface of the ground or surface waters El ® Discharge or ponding of effluen due to an overloaded or clogged SAS or cesspool Title 5 Official Inspection Form'.Subsurface Sewage Disposal System•Page 4 of 18 t5insp.doc•rev.7/26/2018 c Commonwealth of Massachusetts { Title 5 Official Inspection Form , Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 6 Penni Lane_ Property Address Tierney _ — _ — ——-- — —-- — —------- - Owner Owner's Name information is MA 01845 November 6, 2019 required for every North Andover — — —-- — State Zip Code Date of Inspection page. &ylTown C. Inspection Summary (cont.) 4) System Failure Criteria Applicable to All Systems: (cont.) Yes No ❑ ® Static liquid level in the distribution box above outlet invert due to an overloaded or clogged SAS or cesspool ❑ ® Liquid depth in cesspool is less than 6" below invert or available volume is less than '/2 day flow O ❑ ® Required pumping more than 4 times in the last year NOT due to clogged or obstructed pipe(s). Number of times pumped: ❑ ® Any portion of the SAS, cesspool or privy is below high ground water elevation. ❑ ® Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary to a surface water supply. El ® Any portion of a cesspool or privy is within a Zone 1 of a public water supply well. ❑ ® Any portion of a cesspool or privy is within 50 feet of a private water supply well. ❑ ® Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a private water supply well with no acceptable watera quality a l P certifiedanalysis. [This system passes if the well water analysis, performed laboratory,for fecal coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis and chain of custody must be attached to this form.] ❑ ® The system is a cesspool serving a facility with a design flow of 2000 gpd- 10,000 gpd. ❑ ® The system fails. I have determined that one or more of the above failure criteria exist as described in 310 CM 15.303, therefore the system fails. The system owner should contact the Board of Health to determine what will be necessary to correct the failure. 5) Large Systems: To be considered a large system the system must serve a facility with a design flow of 10,000 gpd to 15,000 gpd. For large systems, you must indicate either"yes" or"no"to each of the following ' ddition to the questions in Section CA.. Yes No system is within 400'feet of a suf ace drinking water supply El ❑ the y ❑ ❑ the system is within 200 feet of a tributary to a surface drinking water supply El El Area system-is located in a nitrogen sensitive area (Interim Wellhead Protection Area.— IWPA) or a mapped Zone II of a public water supply well t5insp.doc•rev.7/2 612 01 8 Title 5 Official Inspection Form Subsurface Sewage Disposal System•Page 5 of 18 cam , Commonwealth of Massachusetts Title 5 official Inspection Form sments Subsurface Sewage Disposal System Form Not for Voluntary As 6 Penni Lane ------ ---------- -- ---- _v� Property Address Tierney_ --------------------- Owner Owner's Name information is MA_ 01845_— N_oyember_6, 2019 — required for every NOrth AndOVBr _—__— -- - State Zip Code Date of Inspection page City/Town C. Inspection Summary (cont.) If you have answered "yes" to any question in Section C.5 the system is considered a significant threat, or answered "yes"to any question in Section CA above the large system has failed. The owner or operator of any large system considered a significant threat under Section C.5 or failed under Section CA shall upgrade the system in accordance with 310 CMR 15.304. The system owner should contact the appropriate regional office of the Department. 6. You must indicate "yes" or"no"for each of the following for all inspections: Yes No ® ❑ Pumping information was provided by the owner, occupant, or Board of Health ❑ ® Were any of the system components pumped out in the previous two weeks? ® ❑ Has the system received normal flows in the previous two week period? Have large volumes of water been introduced to the system recently or as part of ❑ ® this inspection? / Were as built plans of the system obtained and examined? (If they were not available note as N/A) ® ❑ Was the facility or dwelling inspected for signs of sewage back up? ® ❑ Was the site inspected for signs of break out? ® ❑ Were all system components, excluding the SAS, located on site? ® ❑ Were the septic tank manholes uncovered, opened, and the interior of the tank inspected for the condition of the baffles or tees, material of construction, dimensions, depth of liquid, depth of sludge and depth of scum? ® ❑ Was the facility owner(and occupants if different from owner) provided with information on the proper maintenance of subsurface sewage disposal systems? The size and location of the Soil Absorption System (SAS) on the site has been determined based on: ® ❑ Existing information. For example, a plan at the Board of Health. ® El approximation in the field (if any of the failure criteria related to Part C is at issue approximation of distance is unacceptable) [310 CMR 15.302(5)] Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 6 of 18 t5insp.doc•rev.7/2 612 01 8 c � Commonwealth of Massachusetts fficial Inspection Form Title 5 O r Voluntary Assessments i� Subsurface Sewage Disposal System Form -Not fo 6 Penni Lane ----- - ------- --- ------ —— — ----- Property Address Tierney -- — —— --- ---——— --------- Owner Owner's Name November 6, 2019 information is North Andover —_ MA _ _0184_5—— _ -- required for every ----- --—— State Zip Code Date of Inspection page. Cityrrown D. System Information 1. Residential Flow Conditions_ 4 4 --- Number of bedrooms (actual): — Number of bedrooms (design): 440 gpd DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x#of bedrooms): - --- — Description: Town and owner. 0 Number of current residents: Does residence have a garbage grinder? ® Yes ❑ No Does residence have a water treatment unit? ❑ Yes ® No If yes, discharges to: - --- — Is laundry on a separate sewage system? (Include laundry system inspection ❑ Yes ® No information in this report.) ❑ Yes ® No Laundry system inspected? ❑ Yes ® No Seasonal use? Water meter readings, if available (last 2 years usage (gpd)): 6G✓� Detail: -- ——-- - - ® Yes ❑ No Sump pump? 2 weeks ago__ Last date of occupancy: Date Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 7 of 18 t5insp.doc•rev.7/26/2018 cam, Commonwealth of Massachusetts . , Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments 6 Penni Lane ___ __— --- ------ Property Address Tierney ---- — --------------- — -- ---------- Owner Owner's Name Q1$45 November 6, 2019 information is _North Andover _ _ — _MA __ __-- - required for every — — — — — State Zip Code Date of Inspection page. City/Town D. System Information (cont.) 2. Commercial/industrial Flow Conditions: Type of Establishments _, Design flow(based on 310 CMR 15.203): Gallons pe (gPd) Basis of design flow (seats/persons/sq' etc.): Fyn ❑ Yes ❑ No Grease trap present? < ❑ Yes ❑ No Water treatment unit present? If yes, discharges to: — --- —— ❑ Yes ❑ No Industrial waste holding tank present? '` ❑ Yes ❑ No Non-sanitary aste discharged to the Title 5 system? Water meter readings, if available: Last date of occupancy/use: Date Other(describe below): 3. Pumping Records: Source of information: — Was system pumped as part of the inspection? Yes ® No zero —_ —-- -- If yes, volume pumped: gallons— -- -------- How was quantity pumped determined? no need_at this time — _.------- Reason for pumping: Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 8 of 18 t5insp.doc•rev.7/26/2018 Commonwealth of Massachusetts �a Title 5 official Inspection Form sments r Subsurface Sewage Disposal System Form - Not for Voluntary •y ` ! 6 Penni Lane ---- — — — — --------- -------- v Property Address Tierney -------- -- -- ----------- -- -- - -- ------- Owner Owner's Name _ -November 6, 2019 information is MA 01845 — N_ove_ -- required for every North Andover _— _ _-— —-- — State Zip Code Date of Inspection page. Cityrrown D. System Information (cont.) 4. Type of System: ® Septic tank, distribution box, soil absorption system (] Single cesspool Overflow cesspool Privy Shared system (yes or no) (if yes, attach previous inspection records, if any) Innovative/Alternative technology. Attach a copy of the current operation and maintenance contract(to be obtained from system owner) and a copy of latest inspection of the I/A system by system operator under contract Tight tank. Attach a copy of the DEP approval. El Other(describe): Approximate age of all components, date installed (if known) and source of information: System is from 2005 - 14 years old. ___ —_— —_-------- --- Were sewage odors detected when arriving at the site? Yes ® No 5. Building Sewer(locate on site plan): Depth below grade: feet Material of construction: 40 PVC ❑other(explain): -- — — j cast iron ® ---- — / Distance from private water supply well or suction line: feet Comments (on condition of joints, venting, evidence of leakage, etc.): Main line and joints are in good condition, no signs of any problems. Title 5 Official Inspection Form Subsurface Sewage Disposal System•page 9 of 18 t5insp.doc•rev.7/26/2018 Commonwealth of Massachusetts Title 5 Official Inspection For msessments Subsurface Sewage Disposal System Form Not for Voluntary 6 Penni Lane_— —_-- --- — — — — Property Address --— Tierney----- -- — --- ------ --- --- --- ----- Owner Owner's Name November 6, 2019 information is _ _—__ MA _ 01845 _ — - required for every _ --- — State Zip Code Date of I North Andover nspection page. City/Town D. System Information (cont.) 6. Septic Tank (locate on site plan) Depth below grade: feet Material of construction: / ® concrete ❑ metal Elfiberglass ❑ polyethylene ❑ other(explain) 1500 gallon precast concrete. — -- --u --`s.—"R�w �np` L -a. lj '`SCeu If tank is metal, list age: �,fprtif �„ ,,..r,,�.,,....,. ,. Is age c��med by a Certificate of Compliance? (attach a copy icate) ❑ Yes o 5' x5' x10' - 1500gallons — Dimensions: Sludge depth: 34" — —--- Distance from top of sludge to bottom of outlet tee or baffle --- Scum thickness Distance from top of scum to top of outlet tee or baffle Distance from bottom of scum to bottom of outlet tee or baffle by sticks and tape measure — — How were dimensions determined? Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): The septic tank and baffles are in good general condition. The liquid in the tank is running at it's correct working heigth. �►as G- gas J/_� a — -- ---- Title 5 Official Inspection Form Subsurface Sewage Disposal System•Page 10 of 18 t5insp.doc•rev 7/26/2018 Commonwealth of Massachusetts w Title 5 Official Inspection Form sments lis Subsurface Sewage Disposal System Form Not for Voluntary Ass C � 6 Penni Lane — -- ------ ----- --- -- L Property Address — Tierney------— ----- --- --- -----------— Owner Owner's Name November 6, 2019 information is MA 01845 — North Andover —ate of Inspection — — required for every -- ------— — —— State Zip Code D page. cityrrown D. System Information (cont.) 7. Grease Trap (locate on site plan): Depth below grade: feet (� Material of construction: v ❑ concrete ❑ metal ❑fiberglass ❑ polyethylene ❑ other(explain): Dimensions: Scum thickness Distance from top of scum to top of outlet tee or baffle --- -- Distance from bottom of scum to bottom"of outlet tee or baffle Date of last pumping: Date Comments (on pumping.recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels as related to outlet invert, evidence of leakage, etc.): 8. Tight or Holding Tank (tank must be pumped at time of inspection) (locate on site plan): Depth below grade: Material of construction: rr� fiberglass. polyethylene ❑ other(explain): V ❑ concrete ❑ metal ❑ glass, Dimensions: Capacity: gallons Design Flow: gallons per day Title 5 Official Inspection Form'.Subsurface Sewage Disposal System•Page 11 of 18 t5insp.doc•rev.7/2 612 01 8 Commonwealth of Massachusetts fficial Inspection For sessments m Title 5 O � �j� Subsurface sewage Disposal System Form - Not for Voluntary 6 Penni Lane -_ __ ---------- Property Address ---— __--- Tierne ___ - - Owner owner's Name MA 01845 November 6 2019 information is _ _ -- required for every NOrth Andover_ _ __ _— -- --- State Zip Code Date of Inspection page. Cityrrown D. System Information (cont.) 8. Tight or Holding Tank(cont.) ❑ Yes ❑ No Alarm present: ,, - -- - Alarm in working orde_t:- ❑ Yes ❑ No Alarm level: Date of last pumping: Date Comments (condition of alarm and float switches, etc:)",- Attach copy of current pumping contract(required). Is copy attached? ❑ Yes ❑ No 9. Distribution Box (if present must be opened) (locate on site plan): Zero _-_—-- --- - Depth of liquid level above outlet invert —--- Comments (note if box is level and distribution to outlets equal, any evidence of solids carryover, any evidence of leakage into or out of box, etc.): The d-box is 7" below grade and is 16" by 16" square. The d-box is level and in good condition. The d-box has speed levels. - ----- —__--__— Title 5 Official Inspection Form!Subsurface Sewage Disposal System•Page 12 of 18 t5insp.doc•rev.7/26/2018 Commonwealth of Massachusetts Title 5 official Inspection For msessments w, Subsurface Sewage Disposal System Form - Not for Voluntary 6 Penni Lane _ ---------- ------------- v Property Address --- Tierne — — --— Y —_.---- - -- -- - -- — - -- - Owner Owner's Name Nth Andover MA01845 November 6, 2019 _—-- information is or _ — _— —-- - — — required for every — ------ — State Zip Code Date of Inspection page. city own D. System Information (cost.) i 10. Pump Chamber(locate.,on site plan): i" ❑ Yes No* Pumps in working order: Yes ❑ No` Alarms in working order: Comments (note condition of pump chamber, condition' mps and appurtenances, etc.): * If pumps or alarms are not in working order, system is a conditional pass. 11. Soil Absorption System (SAS) (locate on site plan, excavation not required): If SAS not located, explain why: Located by snake with transmitter. ----------- Type: ❑ leaching pits number: -- ❑ leaching chambers number: --- ❑ leaching galleries number: ❑ leaching trenches number, length: -- 1 15' x40' ® leaching fields number, dimensions: - ❑ overflow cesspool number: ---- ❑ innovative/alternative system Type/name of technology: -- ------ Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 13 of 18 t5insp.doc•rev.7/26/2018 Commonwealth of Massachusetts x Title 5 Off Not for Voluntary Assessments Inspection Form Sments � lii� Subsurface Sewage Disposal System Form - Property Address - ----- - Tierney--------- --- --- - - - -------- - owner owner's Name MA 01845 November 6, 2019 information is North Andover - - -- --— State zip Coae Date of Inspection required for every _._.------- — page. City/Town D. System Information (cont.) 11. Soil Absorption System (SAS) (cont.) Comments(note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition of / vegetation, etc.): / The SAS is in good general condition with no signs of any problems. ----------------- CoLter - ------- --- - ---- ---- -------------- 12. Cesspools (cesspool must be pumped as part of inspection) (locate on site plan): Number and configuration ' _ f r� Depth-top of liquid to inlet invert Depth of solids layer Depth of scum layer --- — — Dimensions of cesspool Materials of construction ._ Indication of groundwater inflow ❑ Yes ❑ No Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.): Title 5 Official Inspection Form:Subsurface Sewage Disposal System Page 14 of 18 t5insp.doc•rev.7/2612018 c Commonwealth of Massachusetts Title 5 Official Inspection Form a Subsurface Sewage Disposal System Form Not for Voluntary Assessments 6 Penni Lane — ---------------- ---- -------------- Property Address _-- Tierney-- ---------------- - --- --- ------- --- Owner pwner's Name 01845 November 6, 2019 N information is North Andover — — _ MA_ _ — — required for every — — — —— — State Zip Code Date of Inspection page. CitylTown D. System Information (cont.) 13. Privy (locate on site plan): Materials of construction: f --—— Dimensions °- —rr,,•-�� -- --- ---- Depth of solids �-� Comments(note condition of soil, signs of hyd.raulic.,failure, level of ponding, condition of vegetation, etc.): Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 15 of 18 t5insp.doc•rev.7126/2018 Commonwealth of Massachusetts Title 5 Official Inspection Form sments � i% Subsurface Sewage Disposal System Form - Not for Voluntary u 6 Penni Lane --- ----- Prope yrt Address — Tierney --- --------------- ---— Owner Owner's Name _ _, - "� 0_1845 November 6, 2019 _ North Andover ——-- MA-- — — Date of Inspection required for every _ --- ---- ——— State Zip Code page. Cify—rf n D. System Information (cost.) 7�.nn l* 14. Sketch Of Sewage Disposal System: Provide a view of the sewage disposal system, including ties to at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters the building. Check one of the boxes below: ® hand-sketch in th area below ❑ drawing attached eparately c� S R gc�agcs 1 e Ida-, i t 4 f a �t�T Wit p tax - 3,t aNxr �u AroD � r3 i' I SA .9. Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 16 of 18 t5insodoc•rev.7/26/2018 Commonwealth of Massachusetts Title 5 Official Inspection Form Not for Voluntary Assessments i Subsurface Sewage Disposal System Form - say 6 Penni Lane -- ---- — ------ ---- --- --- �� Property dr Adess — Tierney ----- — - — --—— —----- ——--- --— --- --- Owner Owner's Name November 6, 2019 _ information is MA 01845 _ _— required for every North Andover — ___ _ --—--- State Zip Code Date of Inspection page. Cityrrown D. System Information (cont.) 15. Site Exam: �t ® Check SlopeU ® Surface water rl"j) ® Check cellar Camp PLA "� ® Shallow wells ILI&IX Estimated depth to high ground water: feet Please indicate all methods used to determine the high ground water elevation: ® Obtained from system design plans on record 9/28/05If checked, date of design plan reviewed: pate ® Observed site (abutting property/observation hole within 150 feet of SAS) ® Checked with local Board of Health - explain: Permit and proposed_ D Checked with local excavators, installers- (attach documentation) Accessed USGS database-explain: You must describe how you established the high ground water elevation: Basement is 7' below grade with a sump pump. Deep hole test done 9/28/05 showed ESHWT at 52" and at 48" below grade. by B. Dufrense, Merrimack Engineering Services. Penni Lane sits approx 7' below the grade of the back yard of where the system is located. Before filing this Inspection Report, please see Report Completeness Checklist on next page. Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 17 of 18 l5insp.doc•rev.7/26/2018 Commonwealth of Massachusetts �r ,0 Title 5 official Inspection FormSments l� Subsurface Sewage Disposal System Form Not for Voluntary Asses 6 Perini Lane — -- --------- --- -------- -- V� Property Address Tierney _ - — -------------- Owner owner's Name— November 01845 Novber 6, 2019 information is _North Andover — ___ MA —_ — — ---- required for every - ---- — — State Zip Code Date of Inspection page. Cityrrown E. Report Completeness Checklist Complete all applicable sections of this form inclusive of: ® A. Inspector information: Complete all fields in this section. ® B. Certification: Signed & Dated and 1, 2, 3, or 4 checked ® C. Inspection Summary: 1, 2, 3, or 5 completed as appropriate 4 (Failure Criteria) and 6 (Checklist) completed ® D. System Information: For 8: Tight/Holding Tank— Pumping contract attached For 14: Sketch of Sewage Disposal System drawn on pg. 16 or attached For 15: Explanation of estimated depth to high groundwater included Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 18 of 18 t5insp doc•rev.7/26/2018 n 0 Town of North Andover HEALTH DEPARTMENT s�cNusa CHECK#: DATE: '��-/y.•��/9 LOCATION; H/O NAME: �? . / CONTRACTOR NAME:,f (--` ` Type of Permit or License:(Check box) ❑ Animal $ ❑ Body Art Establishment $ f ❑ Body Art Practitioner $ ❑ Dumpster $ I ❑ Food Service-Type: $ ❑ Funeral Directors $ ❑ Massage Establishment $ : ❑ Massage Practice $ ❑ Offal(Septic)Hauler $ ❑ Recreational Cantp $ ❑ Sun tanning $ ❑ Swimming Pool $ ❑ Tobacco $ ❑ Trash/Solid Waste Hauler $ ❑ Well Construction $ SEPTIC Systems: k ❑ Septic-Soil Testing $ i € ❑ Septic-Design Approval $ ❑ Septic Disposal Works Construction(DWC) $ ❑ Septic Disposal Works Installers(DWI) $ ❑ Title 5 Inspector $ ❑ Title 5 Report $ `.v ❑ Other. (Indicate) $ H lth Agent Initials r White-Applicant Yello -Health Pink- Treasurer