Loading...
HomeMy WebLinkAboutSite Plan - Plans - 240 CHARLES STREET 5 4 3 2 1 �AO/ �` G a �J X /� 0 Ho / � HH G �6 TREET ---- s \ Ho y ti P"=Com VIE W S �s „CLAY s _" R'�IER S 6 AY PROJECT�S H0�\ GL �� _ S �� V G RIVERSIDE PUMP s s \ � � � \ STATION dd O jJ� EOP 9 M s c ti STANDBY GENERATOR D M s G G C P-1 6/ 100 YEAR FLOOD PLAIN --- M / 6" / S M EL.33.4 -- \ 8' TOP OF 84"PIPE M \ ----- - y8 0 RIVERVIEW STREET T.B.M.D BOLT 0 ER - Z_ C q/k/T//f F EL.23.68 AT CB / S \� NORTH ANDOVER,MA 01845 MAIN OUT�OF / _ -_ ENCE --- -� M \'' CLIENT M - - - _ / 200'RIVERFRONT AREA ye \ HYDRAf�T ,' -------- MV/S1 -----_ 30 R=2778 �ATION=36.40 M - - --- �� '' ---- 9 so4_ - ��! 1=16.3(sE> EH� GREATER LAWRENCE / M ----------- __-------�00 YEAR FLOnD�Pt�IN-- - - - _ 1-16.2(NW) �+ _+ 37-� ELECTRIC / � CONNECT FENCE ❑� SANITARY DISTRICT Cl ----------------- ------ �� '�� _ HANDHOLE T _ ELECTRIC TO EXIST.FENCE 2ga, 240 CHARLES STREET M RE ---- ---------_« __��`� INV.EL. 19.0 -_MANHOLE SOP FEN "---- «� «��« 32 _ / \ tiG NORTH A612 tel ,MA 01845 685.7 M/ GNp,IN K -- 31 +� -_ 84 --- 978.685.1612 tel 978.685.7790 fax IN ---- - O 3`_ B �4 3 CoC``l`�T INFILTRATION/ ___- �- CRUSHED STONE INFILTR N + E '34__ - �2 _� - 1.52 TRENCH.SEE NOTE 4. � S, / �o \ ti� \6s CONSULTANT mvi i �,�, ( 8'HIGH CLF.LOCATE 10' AECOM TECHNICAL SERVICES,INC. REE STUMP (TYP.)O O O 9 C-504 ❑❑❑ -4,l sSW)� FROM GENERATOR CONC.PAD./P \ y� 4 250 APOLLO DRIVE 9��4 \ // 8�� \ � R, PHONE: (978)9 MA 01824 __ ' ' ` PHONE:FOR 9 MA BENCHMARKJ/50 FOUND E �� ��•_ � ` LEFT FRONT BONNET '�4" / 32 +`?o Y yO www.aecom.com BOLT OF yyU i �' ELEv 36 U U MV�S1 + \ �y PINE �C 9 -504 CONC.PAD T.O.C.EL.33.5 6" \ ELECTRicAL TRANSFORMER � SEE NOTE 9 + R Q N 0 W i STA ON I c � TERMINATE MV1 RASS O i Z � �6 CONDUIT INSIDE _�o N EXISTING TERMINATION O -31 o s GRASS P N E z 9 C-504 C Q BOX FROM BOTTOMO \� / GRASS 2 s f STATION 2 N 1` / HOOD GENERATOR / J 1 .;,:,;',�.,�;':;::::`.::;:;:::::+ SPIKE SET HI/MH#1 Q / e ENCLOSURE i + N 308341437 SEE NOTE 10 E 754698.02 E o ® +ELEV=34.g3 _ g EXISTING POWER / . ' 0 m PULL BOX LL-1 CB ` + LL1 CONTAINMENT TANK RIM EL 32.25 Q. 3 k EXISTING SIGNAL oy R ° ACCESS COVER. SEE NOTE 11 =30.66 + F PULL BOX SEE NOTE 8. 33.10 x x 32.50 1+24.8(NE)' 2 PULL EXISTING BOX CONTROL �r---= �� 1=24.9(SW) �UQ / II II CB \ I II Co � ,x 6"PVC DRAIN + F + 34.84 34.so 3411 j 355 6"PVC DRAIN 3. E SGC 34 36 SGC 34,18 33.89 5'G - -- �� � S EL / 3 3z13 CONNECT FENCE R=30.69 REGISTRATION 32.50 TO EXIST.FENCE CONNECT 6"DRAIN (SILTED) v \ 32.51 \Q / 1 32.70 32.30 I / /TO EXIST.BRICK CB 1-25.4t(NE) Q+ T.O.C. \ 32.75 6"GATE VALVE WITH POST INDICATOR.+ CB / EL.32.3 x o 34.37+ 09+ / 3E.64+ VALVE NORMALLY OPEN,CLOSE FOR U EL. + / 1 32 9 z.45+ FUEL DELIVERY.SEE NOTE 5. vO+V 32.51+ 9 c15o4 / 32.60 32.50 GUARD POST FUEL DELIVERY TRUCK \ BELOW GRADE 3,500 GALLON / 8'HIGH MANUAL SWING GATE ONC BASE / (SHOWN FOR CLARITY)s DUCTBANK(TYP.) ECAST CONCRETE SPILL 3 88 TO REPLACE EXISTING GATE B LEC RISERS A . NTAINMENT TANK sTnoN#3 V' 4.48 33.ss __33.00- 32 9 32.30 _ 7 /N 3OB527os❑ "G J 32.75 6 FT.WIDE BIT.CONC.SPEED HUMP E 7545JEO77 P kko j ssff - + 32.70 TO ACT AS SPILL CONTAINMENT BERM. ELEV=3/.4a T.O.C. 9Ta / ff� SPILL CONTAINMENT AREA.° 31 11 ---1 -- NEW PAVEMENT TO MEET AND MATCH EL.32.3 j 14'x12'PAVED AREA EXISTING PAVEMENT. x SEE NOTE 7 3 �' 100'WETLAND BUFFER + SLOPED TO CATCH BASIN. i w �+ I � L p� ISSUE/REVISION U O + s - m AREA OF NEW PAVEMENT, E e=3 5.6 8 O C�_ 2 + / ' 16'x2O',SLOPED TO DRAINLLI �I Q r X�l, TO NEW CATCH BASIN O 100 YEAR O 6 I FLOOD PLAIN Co + EL.33.4 - R=28.94 + '- 2� 16.4(N) \ I/R DATE DESCRIPTION SMH PROJECT NUMBER Y v 60501489 NOTES: NOTES CONT): ` I + � ,' Designed By: T.SHEA O �o so T ---___ �' H 1. FOR LEGEND,ABBREVIATIONS AND GENERAL NOTES,SEE SHEET 00 C-001. 6. CONTRACTOR SHALL RESTORE DISTURBED AREAS WITH LOAM AND SEED AT COMPLETION Drawn By: S.NAPOLITANO B-1 / \ 90 / OF MAJOR WORK ACTIVITY.CONTRACTOR SHALL RESTORE ALL OTHER AREAS DISTURBED W I '+ I / 2. FOR DETAILS,SEE 99 SERIES OF CIVIL SHEETS. BY HIS ACTIVITIES INCLUDING ASPHALT AND CURBING. Dept Check: C.BENZIGER w W J 3360 Proj Check: R.ADAMS i R I x / 3. THE EXISTING CONDITIONS SHOWN ON THIS PLAN ARE POST DEMOLITION,I.E.AFTER 7. CONTRACTOR TO INSTALL SLOPED GRANITE CURBING ALONG ACCESS DRIVE TO CLOSE O O + s m / DEMOLITION OF EXISTING FENCING,CURBING,ETC.FOR COMPLETE EXISTING CONDITIONS, OFF OPENING TO WALK. Date: AUGUST 2019 A U O I,O + SEE SHEET 00 C-101. Scale: AS NOTED w W O + 3 s S 8. CONTAINMENT TANK FRAME AND COVER TO BE NEENAH FOUNDRY,MODEL NO.R-1557, w � s yr l 0 4. THE CRUSHED STONE INFILTRATION TRENCH WILL BE A MINIMUM OF 2 FEET WIDE AND HEAVY DUTY,OR APPROVED EQUAL.ADJUST HEIGHT WITH BRICK AND MORTAR OR TE GRADING RINGS. m a , DISCIPLINE " 3 2 FEET DEEP ON THREE SIDES OF THE GENERATOR CONCRETE PAD(NO TRENCH ON PRECAST CONCRE MR N C) �9 / 7 1 / THE NORTHWEST SIDE)AND WILL ALSO BE PLACED UNDER THE GENERATOR HOODS. CIVIL o M e 1 9. APPROXIMATE LOCATION OF EXISTING,BURIED GROUNDING TRIAD. SHEET TITLE 35.67 \ + 0 1 // 306 5. THE CONTRACTOR SHALL PROVIDE AND INSTALL MUELLER CO.6"RESILIENT WEDGE GATE o / �/T ' VALVE,MODEL NO.P-2361,OR APPROVED EQUAL,WITH OPEN LEFT HAND CRANK AND 10.CONDUIT TO BE EXTENDED A MINIMUM OF 6'ABOVE TOP OF CONCRETE,PLUMB. SITE PLAN MECHANICAL JOINT FITTINGS WITH MUELLER CO.POST INDICATOR MODEL NO.A20806, a OR APPROVED EQUAL,PAINTED BLACK. 11.PRIOR TO PLACING THE CONCRETE FOUNDATION,CONNECT 250KCM BARE COPPER a GROUND CONDUCTOR TO GENERATOR PAD REBAR USING COMPRESSION TYPE a LL PLAN 0 10 20 30 CONNECTIONS(TYP.OF 3 OUTSIDE CORNERS OF FOUNDATION).FOR EACH CONNECTION w TO THE REBAR,BUNDLE 20'OF WIRE FOR FUTURE CONNECTION TO GROUND GRID. SCALE: z a m 1"=1 0' 1"=10' SHEET NUMBER o< o SCALE FEET 12, 250 KCM BARE COPPER GROUND CONDUCTOR BURIED 30"BELOW FINISHED GRADE. 00 C-1 03 o O a a a 5 4 3 2 1