HomeMy WebLinkAboutKitchen Hood Inspection - Inspection - 500 GREAT POND ROAD 10/10/2019 Report of Inspection/Test Annual NFPA 9 6 17/17A,Annual N FPA 1 M.PA L;a 10/1012019 Property b :Justin FarringtonFIRL NORTH AND OVER COUNTRY CLUB MA CC-005745Ha mpshi re Drive,H udso n,14 H 03051 081 Salem, NH 1802 (603)293-7 31 Building �� �- 61 oaks s�reet�1�rcester,FAA 01608 . MA (508)882-7227 90 GREAT POND ROAD WN&GETFIREPROTE TiON-COM NORTH ANDVER MA 01845 Jeff Isbell 978- 7-7414 Reference Number: 17219330 Report of Inspection/Test for.-Asset .'.XI DDE WH DR 400S X2 :''.''.:KITCHEN Kitchen Hood Informatio.n... .... Manufacturer i IDDE Model vHDR 400 Cylinder Size Master 400S Cylinder Size Slave 40 Last Hydro 20 X2 Location of Shut Off asco 1 1\2'# behind appliances Location of Pull Station back deer Fuel Shutoff C" aEsi', "Electric") Number of Links 5@500 Fuse Link 500 F Fuel Shut Off Electric True Fuel Shut Off Gas True Type Wet Protected. pli from .:. Appliance 1 Griddle Appliance 2 Fryer Appliance 3 Oven Appliance 4 Range Appliance 5 Salamander QUE'STI All appliances property covered wlcorr ct nozzle? Yes Duct and plenum covered wlcorrect nozzles? Yes Check positioning of all nozzles. Yes System installed in accordance w/MFG UL listing? Yes Hood/duct penetrations sealed wlweld or UL device? Yes Check If seals intact,evidence of tampering Yes Pressure gauge in proper range if gauged)? Yes Check cartridge weight if applicable) Yes Inspect cylinder and mount Yes Operate system from terminal link 1`e r Test for proper operation from remote Yes Dhel operation of has valve Yes Are the paper nozzle covers In place? Yes Replaced fuse links with new calendar year links? Yes f Check travel of cable nuts/ -hooks Yes Piping&conduit securely bracketed? Yes Exhaust fan in operating order Yes Fuel smut-off in on position? Yes Manual&remote sett earl in place'? Yes Replace systems covers Yes k System operational&seals In place? Yes Slave system operational? NIA Personnel instructed in manual operation of system? Yes Service&Certification tag on system? Yes I: I this system t.1.L. compliant? Yes Does the makeup air shut down? Yes i. Copyright 2019 Inspect Point Page 1 of Report of Inspection/Test Annual NFPA 96 17117A,Annual NF A'10 T-,MkjAL;T 1 11 120 1 Property Conducted by:Justin Farrington NORTH Ai OVER COUNTRY CLUB MA CC-005745 385081 Salem, NH 1 (603)293-7531 Building#: 7117 MA HC-9 oo29 261 6� �(a�652�s le r=x 0 1 K 99 GREAT POND ROAD VOUN.G ETFIREPROTE TION.COM NORTH ANDOVER MA 0 1845 Jeff Isbell 9 - -7414 Reference Number: 17219 System interlocked with building fire alarm? Yes Manual Release Unobstructed? Yes Proper separation between fryers and flame? Yes Fain warning sign on hood's Yee K class fire extlrtiguisher in cooling area? Yes Proper Qty and type of fire extinguishers at location? Yes Fire extinguishers properly inspected and serviced Yes Fire extinguishers last serviced By and date, impact 10119 Suppression system is compliant? Yes Mood grease buildup? Heavy Hood last cleaned date. NIA Portable Fire' ti ishers Inspection List 1 RE EXTINGUISHER G ROU PLocation Dose.:.: : te T Size :Status..::'.: 1D# y .. .'.. .'..' } f s f f a r' s i `!: Copyright 2019 Inspect Point Page 2 of