HomeMy WebLinkAboutPass - Title V Inspection Report - 78 VEST WAY 1/28/2020 Commonwealth of Massachusetts
Title 5 Official Inspection Form
III� Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
M � 78 Vest Way
Property Address
Marc Perry
Owner Owner's Name
information is No Andover Ma 01845 1-13-2020
required for every
page. City/Town State Zip Code Date of Inspection
Inspection results must be submitted on this form. Inspection forms may not be altered in any
way. Please see completeness checklist at the end of the form. D
�cc'.E1VE
Important:When A. Inspector Information p20
filling out forms 2 2
on the computer, F.Paul Cardone ��`� DOER
use only the tab ------
key to move your Name of Inspector
.100 DFN PPRTMEN
cursor-do not Septic Compliance,lnc. E
use the return Company Name
key.
37 1/2 Baremeadow Street _
r� Company Address
Methuen Ma. 01844
City/Town State Zip Code
978-815-3115 or 978-681-0726 #3294
Telephone Number License Number
B. Certification
I certify that: I am a DEP approved system inspector in full compliance with Section 15.340 of Title 5
(310 CMR 15.000); 1 have personally inspected the sewage disposal system at the property address
listed above; the information reported below is true, accurate and complete as of the time of my
inspection; and the inspection was performed based on my training and experience in the proper function
and maintenance of on-site sewage disposal systems. After conducting this inspection I have determined
that the system:
1. ® Passes
2. ❑ Conditionally Passes
3. ❑ Needs Further Evaluation by the Local Approving Authority
4. ❑ Fails
I pe tors Signature mate
The system inspector shall submit a copy of this inspection report to the Approving Authority (Board
of Health or DEP)within 30 days of completing this inspection. If the system has a design flow of
10,000 gpd or greater, the inspector and the system owner shall submit the report to the appropriate
regional office of the DEP. The original form should be sent to the system owner and copies sent to
the buyer, if applicable, and the approving authority.
Please note: This report only describes conditions at the time of inspection and under the
conditions of use at that time. This inspection does not address how the system will perform
in the future under the same or different conditions of use.
t51nsp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 1 of 18
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
78 Vest Way
Property Address
Marc Perry
Owner Owner's Name
information is No Andover Ma 01845 1-13-2020
required for every
page. City/Town State Zip Code Date of Inspection
C. Inspection Summary
Inspection Summary: Complete 1, 2, 3, or 5 and all of 4 and 6.
1) System Passes:
® I have not found any information which indicates that any of the failure criteria described
in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are
indicated below.
Comments:
2) System Conditionally Passes:
❑ One or more system components as described in the "Conditional Pass" section need to be
replaced or repaired. The system, upon completion of the replacement or repair, as approved by
the Board of Health, will pass.
Check the box for"yes", "no" or"not determined" (Y, N, ND) for the following statements. If"not
determined," please explain.
The septic tank is metal and over 20 years old* or the septic tank (whether metal or not) is structurally
unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass
inspection if the existing tank is replaced with a complying septic tank as approved by the Board of
Health.
* A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of
Compliance indicating that the tank is less than 20 years old is available.
❑ Y ❑ N ❑ ND (Explain below):
t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 2 of 18
c Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
0 78 Vest Way
Property Address
Marc Perry _
Owner Owner's Name
information is required for every No Andover Ma 01845 1-13-2020
--
page. City(Town State Zip Code Date of Inspection
C. Inspection Summary (cont.)
2) System Conditionally Passes (cont.):
❑ Pump Chamber pumps/alarms not operational. System will pass with Board of Health approval if
pumps/alarms are repaired.
❑ Observation of sewage backup or break out or high static water level in the distribution box due
to broken or obstructed pipe(s) or due to a broken, settled or uneven distribution box. System will
pass inspection if(with approval of Board of Health):
❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below):
❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below):
❑ distribution box is leveled or replaced ❑ Y ❑ N ❑ ND (Explain below):
❑ The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The
system will pass inspection if(with approval of the Board of Health):
❑ broken pipe(s) are replaced ❑ Y ❑ N ❑ ND (Explain below):
❑ obstruction is removed ❑ Y ❑ N ❑ ND (Explain below):
N/A
3) Further Evaluation is Required by the Board of Health:
❑ Conditions exist which require further evaluation by the Board of Health in order to determine if
the system is failing to protect public health, safety or the environment.
a. System will pass unless Board of Health determines in accordance with 310 CMR
15.303(1)(b) that the system is not functioning in a manner which will protect public health,
safety and the environment:
t51nsp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 3 of 18
<�,\ Commonwealth of Massachusetts
Title 5 Official Inspection Form
�1� Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
78 Vest Way
Property Address
Marc Perry
Owner Owner's Name
information is required for every No Andover Ma 01845 1-13-2020
page. City/Town State Zip Code Date of Inspection
C. Inspection Summary (cont.)
❑ Cesspool or privy is within 50 feet of a surface water
❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh
b. System will fail unless the Board of Health (and Public Water Supplier, if any)
determines that the system is functioning in a manner that protects the public health,
safety and environment:
❑ The system has a septic tank and soil absorption system (SAS) and the SAS is within
100 feet of a surface water supply or tributary to a surface water supply.
❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water
supply.
❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water
supply well.
❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or
more from a private water supply well".
Method used to determine distance: N/A
** This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal
coliform bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal
to or less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis must
be attached to this form.
c. Other:
4) System Failure Criteria Applicable to All Systems:
You must indicate "Yes" or"No" to each of the following for all inspections:
Yes No
El ® Backup of sewage into facility or system component due to overloaded or
clogged SAS or cesspool
❑ ® Discharge or ponding of effluent to the surface of the ground or surface waters
due to an overloaded or clogged SAS or cesspool
t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 4 of 18
c � Commonwealth of Massachusetts
�x Title 5 Official Inspection Form
II; Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
78 Vest Way
Property Address
Marc Perry
Owner Owner's Name
information is required for every No Andover Ma 01845 1-13-2020
page. City/Town State Zip Code Date of Inspection
C. Inspection Summary (cont.)
4) System Failure Criteria Applicable to All Systems: (cont.)
Yes No
❑ ® Static liquid level in the distribution box above outlet invert due to an overloaded
or clogged SAS or cesspool
❑ ® Liquid depth in cesspool is less than 6" below invert or available volume is less
than '/2 day flow
❑ ® Required pumping more than 4 times in the last year NOT due to clogged or
obstructed pipe(s). Number of times pumped:
❑ ® Any portion of the SAS, cesspool or privy is below high ground water elevation.
❑ ® Any portion of cesspool or privy is within 100 feet of a surface water supply or
tributary to a surface water supply.
❑ ® Any portion of a cesspool or privy is within a Zone 1 of a public water supply
well.
❑ ® Any portion of a cesspool or privy is within 50 feet of a private water supply well.
❑ ® Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet
from a private water supply well with no acceptable water quality analysis. [This
system passes if the well water analysis, performed at a DEP certified
laboratory,for fecal coliform bacteria indicates absent and the presence
of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,
provided that no other failure criteria are triggered. A copy of the analysis
and chain of custody must be attached to this form.]
❑ ® The system is a cesspool serving a facility with a design flow of 2000 gpd-
10,000 gpd.
❑ ® The system fails. I have determined that one or more of the above failure
criteria exist as described in 310 CMR 15.303, therefore the system fails. The
system owner should contact the Board of Health to determine what will be
necessary to correct the failure.
5) Large Systems: To be considered a large system the system must serve a facility with a
design flow of 10,000 gpd to 15,000 gpd.
For large systems, you must indicate either"yes" or"no" to each of the following, in addition to the
questions in Section CA.
Yes No
❑ ❑ the system is within 400 feet of a surface drinking water supply
❑ ❑ the system is within 200 feet of a tributary to a surface drinking water supply
❑ ❑ the system is located in a nitrogen sensitive area (Interim Wellhead Protection
Area— IWPA) or a mapped Zone II of a public water supply well
t5insp.doc•rev.7/2 61201 8 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 5 of 18
cam, Commonwealth of Massachusetts
Title 5 Official Inspection Form
,I', Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
78 Vest Way
Property Address
Marc Perry
Owner Owner's Name
information is No Andover Ma 01845 1-13-2020
required for every
page. City(Town State Zip Code Date of Inspection
C. Inspection Summary (cont.)
If you have answered "yes" to any question in Section C.5 the system is considered a significant
threat, or answered "yes" to any question in Section CA above the large system has failed. The
owner or operator of any large system considered a significant threat under Section C.5 or failed
under Section CA shall upgrade the system in accordance with 310 CMR 15.304. The system owner
should contact the appropriate regional office of the Department.
6. You must indicate "yes" or"no" for each of the following for all inspections:
Yes No
® ❑ Pumping information was provided by the owner, occupant, or Board of Health
❑ ® Were any of the system components pumped out in the previous two weeks?
® ❑ Has the system received normal flows in the previous two week period?
❑ ® Have large volumes of water been introduced to the system recently or as part of
this inspection?
® ❑ Were as built plans of the system obtained and examined? (If they were not
available note as N/A)
® ❑ Was the facility or dwelling inspected for signs of sewage back up?
® ❑ Was the site inspected for signs of break out?
® ❑ Were all system components, excluding the SAS, located on site?
® ❑ Were the septic tank manholes uncovered, opened, and the interior of the tank
inspected for the condition of the baffles or tees, material of construction,
dimensions, depth of liquid, depth of sludge and depth of scum?
Was the facility owner(and occupants if different from owner) provided with
® El information on the proper maintenance of subsurface sewage disposal systems?
The size and location of the Soil Absorption System (SAS) on the site has
been determined based on:
® ❑ Existing information. For example, a plan at the Board of Health.
❑ ❑ Determined in the field (if any of the failure criteria related to Part C is at issue
approximation of distance is unacceptable) [310 CMR 15.302(5)]
t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 6 of 18
Summary Record Card generated on 1/13/2020 8:22:41 AM by Karen Hanlon Page 1
Town of North Andover
Tax Map # 210-1043-0170-0000.0
Parcel Id 16492
78 VEST WAY
LAUREN & MARK PERRY
78 VEST WAY
NORTH ANDOVER MA 01845
Class 101 Single Family Property Type 1 Residential
Size Total 1.01 Acres
FY 2020
UB Mailing Index
Name/Address Type Loan Number Active/Inact. From Until
LAUREN&MARK PERRY Owner Active
78 VEST WAY
NORTH ANDOVER MA 01845
MILLIKEN,SOPHIA Previous Customer Inactive 11/1/2016
78 VEST WAY
N.ANDOVER, MA
01845
UB Account Maint.
Account No Cycle Occupant Name Active/Inactive
Bldg Id. 17831.0-78 VEST WAY Last Billing Date 1/10/2020
3170496 03 Cycle 03 Active
UB Services Maint.
Account No.3170496
Service Code Rate Charge Multiplier/Users
MISCFEE ADMIN FEE 0.63 5/8 7.82 1/
WTR WATER 01 ALL METER SIZE 103.75 /1
UB Meter Maintenance
Account No. 3170496
Serial No Status Location Brand Type Size YTD Cons
35644525 a Active ERT HH b Badger w Water 0.63 0.63 1779
Date Reading Code Consumption Posted Date Variance
12/11/2019 1813 a Actual 25 1/15/2020 11%
9/17/2019 1788 a Actual 26 10/10/2019 -24%
6/11/2019 1762 aActual 32 7/25/2019 -11%
3/11/2019 1730 a Actual 35 4/16/2019 -11%
12/11/2018 1695 aActual 39 1/22/2019 -53%
9/13/2018 1656 a Actual 92 10/15/2018 84%
6/7/2018 1564 a Actual 46 7/23/2018 26%
3/9/2018 1518 a Actual 37 4/23/2018 -2%
12/8/2017 1481 a Actual 36 1/25/2018 -68%
9/12/2017 1445 a Actual 125 10/18/2017 176%
6/8/2017 1320 a Actual 43 7/25/2017 -3%
3/9/2017 1277 a Actual 44 4/12/2017 34%
12/9/2016 1233 aActual 19 1/23/2017 -40%
10/18/2016 1214 f Final Bill 25 10/18/2016 -47%
9/7/2016 1189 a Actual 99 10124/2016 121%
6/13/2016 1090 a Actual 49 8/2/2016 300%
3/11/2016 1041 aActual 12 4/22/2016 -65%
12/10/2015 1029 aActual 34 1/20/2016 -59%
9/9/2015 995 a Actual 83 10/16/2015 82%
6/10/2015 912 a Actual 45 7/24/2015 221%
3/12/2015 867 a Actual 14 4/28/2015 -42%
12/12/2014 853 aActual 25 1/15/2015 -73%
9/10/2014 828 a Actual 91 10/15/2014 363%
6/9/2014 737 a Actual 19 7/16/2014 45%
3/11/2014 718 aActual 13 4/11/2014 -58%
12/12/2013 705 a Actual 32 1/17/2014 -48%
9/12/2013 673 a Actual 63 10115/2013 55%
c � Commonwealth of Massachusetts
Title 5 Official Inspection Form
�11.1 Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
78 Vest Way
Property Address
Marc Perry
Owner Owner's Name
information is required for every No Andover Ma 01845 1-13-2020
page. City/Town State Zip Code Date of Inspection
D. System Information
1. Residential Flow Conditions:
Number of bedrooms (design): 4 Number of bedrooms (actual): 4
DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x#of bedrooms): 440
Description:
Number of current residents: 5
Does residence have a garbage grinder? ® Yes ❑ No
Does residence have a water treatment unit? ❑ Yes ® No
If yes, discharges to:
Is laundry on a separate sewage system? (Include laundry system inspection ❑ Yes ® No
information in this report.)
Laundry system inspected? ❑ Yes ❑ No
Seasonaluse? ❑ Yes ® No
Water meter readings, if available last 2 ears usage d Enclosed
9 ( Y 9 (gP ))�
Detail:
Sump pump? ❑ Yes ® No
Last date of occupancy: Currently
Occupied
t5insp.doc-rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 7 of 18
Commonwealth of Massachusetts
Title 5 Official Inspection Form
= Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
78 Vest Way
Property Address
Marc Perry___
Owner Owner's Name
information is required for every No Andover Ma 01845 1-13-2020
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
2. Commercial/Industrial Flow Conditions:
Type of Establishment: N/A
Design flow(based on 310 CM 15.203): Gallons per day(gpd)
Basis of design flow(seats/persons/sq.ft., etc.):
Grease trap present? ❑ Yes ❑ No
Water treatment unit present? ❑ Yes ❑ No
If yes, discharges to: — --
Industrial waste holding tank present? ❑ Yes ❑ No
Non-sanitary waste discharged to the Title 5 system? ❑ Yes ❑ No
Water meter readings, if available:
Last date of occupancy/use: Date
Other(describe below):
3. Pumping Records:
Source of information: Owner and BOH Last time pumped 9-18-19
Was system pumped as part of the inspection? ❑ Yes ® No
If yes, volume pumped: gallons
How was quantity pumped determined?
Reason for pumping:
t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 8 of 18
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
M � 78 Vest Way
Property Address
Marc Perry
Owner Owner's Name
information is required for every No Andover Ma 01845 1-13-2020
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
4. Type of System:
® Septic tank, distribution box, soil absorption system
❑ Single cesspool
❑ Overflow cesspool
❑ Privy
❑ Shared system (yes or no) (if yes, attach previous inspection records, if any)
❑ Innovative/Alternative technology. Attach a copy of the current operation and
maintenance contract(to be obtained from system owner) and a copy of latest
inspection of the I/A system by system operator under contract
❑ Tight tank. Attach a copy of the DEP approval.
❑ Other(describe):
Approximate age of all components, date installed (if known) and source of information:
Tank appears early 1990's outlet was converted from concrete to a pvc tee, and d-box appears to be
relatively new.
Were sewage odors detected when arriving at the site? ❑ Yes ® No
5. Building Sewer(locate on site plan):
Depth below grade: 1.6
p g feet
Material of construction:
® cast iron ® 40 PVC ❑ other(explain):
Distance from private water supply well or suction line: feet
Comments (on condition of joints, venting, evidence of leakage, etc.):
4" cast iron through wall, PVC in house, no apparent leakage anywhere.
t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 9 of 18
C Commonwealth of Massachusetts
Title 5 Official Inspection Form
iV Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
78 Vest Way
V
Property Address
Marc Perry
Owner Owner's Name
information is required for every No Andover Ma 01845 1-13-2020
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
6. Septic Tank (locate on site plan):
Depth below grade: 6"
et
Material of construction:
® concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain)
If tank is metal, list age: years
Is age confirmed by a Certificate of Compliance? (attach a copy of certificate) ❑ Yes ❑ No
Dimensions: 10'x5'x4'
Sludge depth:
2"
Distance from top of sludge to bottom of outlet tee or baffle
Scum thickness 1
Distance from top of scum to top of outlet tee or baffle
Distance from bottom of scum to bottom of outlet tee or baffle
How were dimensions determined? Sludge Judge and Tape Measure
Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity,
liquid levels as related to outlet invert, evidence of leakage, etc.):
We recommend tank be pumped on a yearly basis, inlet baffle concrete in tact, outlet baffle sanitary
Tee, structural integrity appeared to be good, liquid level was good, no evidence of any leakage.
t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 10 of 18
c � Commonwealth of Massachusetts
I , Title 5 Official Inspection Form
j� Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
�� 78 Vest Way
Property Address
Marc Perry
Owner Owner's Name
information is No Andover Ma 01845 1-13-2020
required for every
page. CityrFown State Zip Code Date of Inspection
D. System Information (cont.)
7. Grease Trap (locate on site plan):
Depth below grade: feet
Material of construction:
❑ concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain):
N/A
Dimensions:
Scum thickness
Distance from top of scum to top of outlet tee or baffle
Distance from bottom of scum to bottom of outlet tee or baffle
Date of last pumping: Date
Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity,
liquid levels as related to outlet invert, evidence of leakage, etc.):
8. Tight or Holding Tank (tank must be pumped at time of inspection) (locate on site plan):
Depth below grade:
Material of construction:
❑ concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain):
N/A
Dimensions:
Capacity: gallons
Design Flow:
gallons per day
t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 11 of 18
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
78 Vest Way
Property Address
Marc Perry
Owner Owner's Name
information is required for every No Andover Ma 01845 1-13-2020
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
8. Tight or Holding Tank (cont.)
Alarm present: ❑ Yes ❑ No
Alarm level: N/A Alarm in working order: ❑ Yes ❑ No
Date of last pumping: Date
Comments (condition of alarm and float switches, etc.):
' Attach copy of current pumping contract (required). Is copy attached? ❑ Yes ❑ No
9. Distribution Box (if present must be opened) (locate on site plan):
Depth of liquid level above outlet invert 0-good and even
Comments (note if box is level and distribution to outlets equal, any evidence of solids carryover, any
evidence of leakage into or out of box, etc.):
Box was level, distribution was equal, 4 lines leaving box, all had speed levelers,no solids carryover,
no evidence of leakage in or out of box, box was in good condition,pictures available.
t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 12 of 18
Commonwealth of Massachusetts
-, Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
78 Vest Way
Property Address
Marc Perr
Owner Owner's Name
information is No Andover Ma 01845 1-13-2020
required for every -- -- -----
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
10. Pump Chamber(locate on site plan):
Pumps in working order: ❑ Yes ❑ No*
Alarms in working order: ❑ Yes ❑ No*
Comments (note condition of pump chamber, condition of pumps and appurtenances, etc.):
N/A
* If pumps or alarms are not in working order, system is a conditional pass.
11. Soil Absorption System (SAS) (locate on site plan, excavation not required):
If SAS not located, explain why:
Type:
❑ leaching pits number: — -
❑ leaching chambers number: --
❑ leaching galleries number: -- -
❑ leaching trenches number, length:
® leaching fields number, dimensions: _1 Field 15'x40'
❑ overflow cesspool number:
❑ innovative/alternative system
Type/name of technology: --- —-
t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 13 of 18
Commonwealth of Massachusetts
Title 5 Official Inspection Form
. Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
78 Vest Way _
Property Address
Marc Perry_ _
Owner Owner's Name
information is required for every No Andover — Ma 01845 1-13-2020
--- --- ----- -
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
11. Soil Absorption System (SAS) (cont.)
Comments (note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition of
vegetation, etc.):
Grassy back yard area Good None None No Good
grassy area.
12. Cesspools (cesspool must be pumped as part of inspection) (locate on site plan):
Number and configuration ----- ------- —
Depth —top of liquid to inlet invert — --
Depth of solids layer --
Depth of scum layer
Dimensions of cesspool ---
Materials of construction
Indication of groundwater inflow ❑ Yes ❑ No
Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation,
etc.):
N/A
t5insp.dcc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 14 of 18
c � Commonwealth of Massachusetts
Title 5 Official Inspection Form
lip Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
cy 78 Vest Way
Property Address
Marc Perr _
Owner Owner's Name
information is No Andover Ma 01845 1-13-2020
required for every _-- ----_____ -- ---_----_ _- --
page. City/Town State Zip Code Date of Inspection
D. System Information (cont.)
13. Privy (locate on site plan):
Materials of construction: N/A _
Dimensions --- -- ----
Depth of solids --- - -------- -
Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation,
etc.):
t5insp.doc-rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 15 of 18
Commonwealth of Massachusetts
-, Title 5 Official Inspection Form
i� Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
( � 78 Vest Wad ---- -
Property Address------- -
Marc Perry
Owner - -------- --- ._ _____ ---
Owner's Name
information is No Andover Ma 01845 1-13-2020
required for every
page. Cityrrown State Zip Code Date of Inspection
D. System Information (cont.)
14. Sketch Of Sewage Disposal System:
Provide a view of the sewage disposal system, including ties to at least two permanent reference
landmarks or benchmarks. Locate all wells within 100 feet. Locate where public water supply enters
the building. Check one of the boxes below:
❑ hand-sketch in the area below
❑ drawing attached separately
Water Neur
live" B
I Prwcb
Yin"*
L
t �
A to I)- t` Z.3'W'
bt«tnt � l�`3tt"'
tt r==tS ttut tt't•• t ta,, .
t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 16 of 18
Commonwealth of Massachusetts
WO Title 5 Official Inspection Form
W Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
c "
78 Vest Warr-- - --- -
Property Address
Marc Perry
Owner Owner's Name
information is required for every No Andover Ma 01845 1-13-2020
--i — --------_.--------------- ---
page. Cty/Town State Zip Code Date of Inspection
D. System Information (cont.)
15. Site Exam:
® Check Slope
® Surface water
® Check cellar
® Shallow wells
depth to high round water'. 4'+
Estimated de g
p gfeet
Please indicate all methods used to determine the high ground water elevation:
❑ Obtained from system design plans on record
If checked, date of design plan reviewed: Date
❑ Observed site (abutting property/observation hole within 150 feet of SAS)
❑ Checked with local Board of Health - explain:
❑ Checked with local excavators, installers - (attach documentation)
® Accessed USGS database -explain:
You must describe how you established the high ground water elevation:
All Liquid levels were good, No sump pump,Dry Soil, Essex County Soil Map, Sheet#30, Paxton
Soil,Water>6' deep
Before filing this Inspection Report, please see Report Completeness Checklist on next page.
15insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 17 of 18
Commonwealth of Massachusetts
Title 5 Official Inspection Form
I, Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
,t
78 Vest Wa
Property Address
Marc Perry
Owner Owner's Name
information is required for every No Andover Ma 01845 1-13-2020
--------------—-- -
page. City/Town State Zip Code Date of Inspection
E. Report Completeness Checklist
Complete all applicable sections of this form inclusive of:
® A. Inspector Information: Complete all fields in this section.
® B. Certification: Signed & Dated and 1, 2, 3, or 4 checked
® C. Inspection Summary:
1, 2, 3, or 5 completed as appropriate
4 (Failure Criteria) and 6 (Checklist) completed
® D. System Information:
For 8: Tight/Holding Tank— Pumping contract attached
For 14: Sketch of Sewage Disposal System drawn on pg. 16 or attached
For 15: Explanation of estimated depth to high groundwater included
t5insp.doc•rev.7/26/2018 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 18 of 18
Town of North Andover
;''•�: e %•" � HEALTH DEPARTMENT
CHECK#: DATE: 0
LOCATION:
H/O NAME:
CONTRACTOR NAME:
TYR of Permit or License:(Check box)
❑ Animal $
❑ Body Art Establishment $
❑ Body Art Practitioner $
❑ Dumpster $
❑ Food Service-Type: $
❑ Funeral Directors $
❑ Massage Establishment $
❑ Massage Practice $
❑ Offal(Septic)Hauler $
❑ Recreational Camp $
❑ Sun tanning $
❑ Swimming Pool $
❑ Tobacco $
❑ TrashlSolid Waste Hauler $ _
❑ Well Construction $
SEPTIC Systems:
❑ Septic-Soil Testing $
❑ Septic-Design Approval $
❑ Septic Disposal Works Construction(DWC) $
❑ Septic Disposal Works Installers(DWI) $
❑ Title 5 Inspector $
a 5�
❑ Title 5 Report r $
❑ Other. (Indicate) $
Health Agent Initials
White-Applicant Yellow-Health Pink- Treasurer