Loading...
HomeMy WebLinkAboutDisapproval Letter 6.27.2016 & 6.9.2016 - Correspondence - 500 BOXFORD STREET 1/28/2020 a* • North Andover Health Department Community and Economic Development Division June 27, 2016 Daniel Koravos, P.E. DK Engineering Associates, Inc. 47 Enterprise Drive, #7 P.O. Box 4260 Windham,NH 03087-4260 Re:Subsurface Sewage Disposal System Plan for 500 Boxford Street- Lot 2 (Map 105C, Lot 42) Dear Mr. Koravos, The proposed wastewater system design plan for the above site dated May 24, 2016, Revised on June 15, 2016 and received on June 21, 2016 has been reviewed. Unfortunately, the plan cannot be approved until the following items are corrected. The specific section in Title 5: 310 CMR 15.000, or North Andover regulation that is not met by this design follows each item where applicable. 1. The existing and proposed lot lines should be depicted on the design plan. On page two of three,please depict the original three lots and overlay the proposed two lots being created with the proposed dwellings,proposed systems and all lot line setbacks, the 100' wetland buffer zone, 50' no build zone and 25'no disturbance zone. 2. Indicate why the soil absorption system cannot be proposed greater than 100 feet from the wetland resource area and why you cannot comply with section 3.9 of the North Andover Septic Regulations. There is an area in the southwest corner of the proposed lot that is greater than 100 feet from the wetland resource area. Please research alternative designs and site layouts that keep the systems out of the 100'buffer zone or designs that achieve maximum feasible compliance. Please also note that Section 3.8 of the North Andover Septic Regulations state that a DEP approved device or alternative technology which reduces wastewater to levels below 30 mg/L BOD and 30mg/L TSS can be approved by the department without a hearing before the Board of Health. I have Page 1 of 2 North Andover Health Department, 1600 Osgood Street, Suite 2035, North Andover, MA 01845 Phone: 978.688.9540 Fax: 978.688.8476 attached a rough sketch that shows 100 linear feet of primary and reserve trenches that are out of the 100' as a rough demonstration. (NA 3.9) 3. The wetland lines have not been confirmed or approved by the North Andover Conservation Commission and may be subject to change. A preliminary site walk by the Conservation Department may be beneficial and reduce additional revisions. 4. On sheet 3 of 3, remove the"untreated building paper" above the peastone layer in the soil absorption system. You may change this and use permeable landscaping fabric. The use of the untreated building paper is not in compliance with Title 5 regulations and will deteriorate rapidly once installed. This does not appear to accomplish the intended outcome stated in your letter dated June 15, 2016. 5. Please submit an additional review fee of$125 with revised plans. Please feel free to contact me at 978-688-9540 or Mill River Consulting at 978-282-0014 with any questions you may have. We look forward to working with you to obtain a wastewater treatment and dispersal system which will be in compliance with all regulations and assure protection of public health and the environment of North Andover. Sincerely, rian J. LaGrasse, CEHT Director of Public Health cc: Michael Donovan Thomas Donovan Cornelius Donovan Andover Consultants, Inc. File Page 2 of 2 North Andover Health Department, 1600 Osgood Street, Suite 2035, North Andover, MA 01845 Phone: 978.688.9540 Fax: 978.688.8476 0i x 1� �% North Andover Health Department Community and Economic Development Division June 9, 2016 Daniel Koravos, P.E. DK Engineering Associates, Inc. 47 Enterprise Drive, #7 P.O. Box 4260 Windham,NH 03087-4260 Re: Subsurface Sewage Disposal System Plan for 500 Boxford Street- Lot 2 (Map 105C, Lot 42) Dear Mr. Koravos, The proposed wastewater system design plan for the above site dated May 24, 2016 and received on June 1, 2016 has been reviewed. Unfortunately, the plan cannot be approved until the following items are corrected. The specific section in Title 5: 310 CMR 15.000, or North Andover regulation that is not met by this design follows each item where applicable. 1. The Assessor's map and lot numbers are not indicated on the design plan (NA 3.2). 2. The existing and proposed lot lines should be depicted on the design plan. 3. TP-6 was not depicted on the design plan (310 CMR 15.220(4)(h)). 4. On sheet 1 of 3, the depths of the test pits and the color of C horizons are incorrect. 5. On sheet 1 of 3,the depth of the ESHWT in TP-4 is incorrect. The soil absorption system design is based on this elevation and needs to be revised to maintain the 5' separation from the bottom of the trenches to the ESHWT. 6. The percolation test results should indicate a percolation rate of<2 mins/inch. 7. On sheet 1 of 3,the graphical representation of the test pits should be shown as they were excavated instead of circles as depicted in the site plan view. 8. Indicate why the soil absorption system cannot be proposed greater than 100 feet from the wetland resource area and maintain compliance with section 3.9 of the North Andover Page 1 of 2 North Andover Health Department, 1600 Osgood Street, Suite 2035, North Andover, MA 01845 Phone: 978.688.9540 Fax: 978.688.8476 f regulation. There is an area in the southwest corner of the proposed lot that is greater than 100 feet from the wetland resource area. 9. No benchmarks were depicted on the design plan(3 10 CMR 220(4)(q)). 10. The foundation drain location and elevation were not depicted on the design plan(NA 3.2). 11. Depict the setback distance from the proposed well to abutting soil absorption systems to ensure compliance with 310 CMR 15.211. 12. On sheet 1 of 3, the building sewer line proposed will likely need a bend either exiting the dwelling or upon entering the septic tank. Please review and propose bends as needed to ensure the inlet tee is located below the manhole access port(3 10 CMR 15.227(l)). 13. On sheet 1 of 3,the septic tank appears to be less than 10' to the proposed dwelling(3 10 CMR 15.211). 14. On sheet 3 of 3,the loading(H-10 or H-20) of the septic tank was not depicted on the design plan(3 10 CMR 15.226(3)). 15. 6"of crushed stone is required beneath the distribution box(3 10 CMR 15.221(2)). 16. On sheet 3 of 3, explain the purpose for the "untreated building paper" above the peastone layer in the soil absorption system. Also explain how the use of the untreated building paper is in compliance with Title 5 regulations. Please feel free to contact the office or Mill River Consulting at 978-282-0014 with any questions you may have. We look forward to working with you to obtain a wastewater treatment and dispersal system which will be in compliance with all regulations and assure protection of public health and the environment of North Andover. Sincerely, ti B an J. LaGrasse, CEHT Director of Public Health cc: Michael Donovan Thomas Donovan Cornelius Donovan Andover Consultants, Inc. File Page 2 of 2 North Andover Health Department, 1600 Osgood Street, Suite 2035, North Andover, MA 01845 Phone: 978.688.9540 Fax: 978.688.8476