HomeMy WebLinkAboutSprinkler Inspection Report - Correspondence - 815 CHESTNUT STREET 1/22/2020 A.S.A.P. Sprinkler LLC SPRINKLER INSPECTION REPORT PAGE 1
Progress Ave. Unit #
Ty ngsboro, Ma. 018719 Phone -649-4945 Fax 97 - 49-9445
company Name Vj ContactVyA\=LA
IVYstreet —City 1 i4 �i f 3 •�► S l a t
Date of Trip Test .. �.�. 4 �--- Technician �. � ��1�'; F�• Dart
Owners Section(To be answered by owner or occupant) ,
A.Explain any occupancy hazard changes since the previous inspection.
B.Describe fire protection modifications made since the last inspection.
C.Describe any fires since the last inspection
D. When was the system piping last checked for stoppage,corrosion or foreign material? ,
E.When was the dry-piping system last checked for proper pitch?
F.Are dry valves adequately protected from freezing?
4
Inspector's Section(Ail responses reference current inspection)
1,GENERAL YES NO
a.Is the building occupied?
b.Are all systems In service?
c.Is there-a minimum of 18 in clearance between the top of storage and sprinkler deflector? `f
d.In areas protected by wet system,does the building appear to be properly heated in all areas including blind
attics and perimeter areas,where'accesible?Do all exterior openings appear to be protected against freezing �
2,CONTROL VALVES{See Item 14) XXXXXXXXX XXXXXXXXX
a.Are all sprinkler system control valves and all other valves in appropriate position? f
b.Are all control valves In the open position and locked,sealed or equipped with tamper?
3.WATER UPPLIES'(see Item 14) XXXXXXXXX XXXXXXXXX.
a.Was a water flow test of maim drain trade at the sprinkler riser?
4.WANKS,PUMPS,FIRE DEPARTMENT CONNECTIONS XXXXXXXXX XXXXXXXX
a.Are fire pumps,gravity tanks,reserviors and pressure-tanks in'good condition and Maintained? ,M
b'.Are FD connection in satisfactory condition,couplings free,caps in place&check valves tight?
Are they accessible and visibl ?
5.WET SYSTEMS(See Item.l ) XXXXXXXXX XXl(}f}(?(XXX
a.Are cold weather valves(O &Y)In the appropr€ate open or closed position?
7
b.Have anti-freeze system solutions b6en tested? �""
c.were the antifreeze test results satisfactory?
6.DRY S STEMS.(See Items 10-14). XXXXXXXXX .:XXXXXXXXX
a.Is the dry valve in service?
b:Are the air pressure&priming water level in accordance with the manufacturers instructions?
c.Were the antifreeze test results satisfactory?
d.Wire 16w points drained during.the inspection?
e.Did quick-opening devices operate satisfactory?
f. Dili the drys valve trip properly during the trip pressure test?
g.Did the heating equipment in the dry-pipe valve room operate at the time of inspection?
7.SPECIAL SYSTEMS(See Item 16) .
XXXXXXXXX XXXXXXXXX
r a. Did the deluge or pre-action valves operate properly during testing?
b. Did the heat-responsive devices operate properly during testing? y
c.laid the sup�rvlsoty alarm service test sansfactoryr?
8.ALARMS' XXXXXXXXX XXXXXXXXX
l a.Did water motor and gong test satisfactory?
b.Did electric alarm test satisfactory? {
c.Did supervisory alarm service test satisfactory?
9.SPRINKLERS }I`}[}(x}{}{xxx XXXXXXXXX
l
a.Are all sprinklers free from corrosion,loading or obstruction to spray discharge?
b.Are sprinklers'-over 50 years old,thus requiring sample testing?
c.Is stock of spare sprinklers available?
d,floes the Interior condition of sprinkler systern appear to be satisfactory
e.Temperature.Are sprinklers of proper temperatuire rating for their location?
#
: p
f
LA
A.S.A.P.Sprinkler LLC INSPECTION TION REPORT Page
6 Progress Ave. Unit#
Tyngsboro..Ma.,..0 Y 7
Phone:' 7 - 43,4945 Fax 78- 4 -9445
Wet Systems No? Make and model?
Dry Systems No Make and model?
Special Systems No? Type?
Make and Model. Condition
10.Date dry-pipe valve trip tested(control valve partially open)
11,Date day-pipe valve trip tested(control valve fulfy open)
12.Date.quick-opening device tested
13.Date deluge or preaction valve tested
14.See Control halve Maintenance Table,
Control Valves Number Type Open Secured Closed Signs' Abnormalities
City Connection Control
Tank Control
Pump Control '
Sectional Control22 Z. V"
System Control u f
Other Control
�.
Water Pressure? Tank PSI Fire Pump
Water flow-te t? (If none made-WILY )
w # ■ ow. Pressure.
r I•'
........... 77
....r
....n..'.......'
16.Heat Responsive Device
Test Method
Type of Equipr ent
C anufacturer
Test Results:
Va I ve Y,,..B C D� Valve k. A�k� D�E� ."
1!a lve##�.. C D� halve ..�.. .,�.� D�
Valve B C D E E Valve A B C D E F
Auxiliary Equipment:No?, Type? Location' Test Result?
17.Explain an "'No"'answers and comments:
f 18.Adjustments or corrections made during this inspection:
E 1 rAlftugh bese comments are ndt the result of an engineering review,the following desirable improvements ate recommended.
f f'
,f #• y t f
Technician .!�,A_ V�� �..� �' License '7 Cust Signatures ate
Y:
k
I-