HomeMy WebLinkAbout- Miscellaneous - 1600 OSGOOD STREET 12/9/2019 EMSLOrder: 241907309
EMSL Analytical, Inc. Customer ID: LANG78
29 North Plains Highway,Unit#4 Wallingford,CT 06492
Customer PO:
Tel/Fax:(203)284-59481(203)284-597,8
http:lhvwmEMSL,comIwaliingfordlab@emsl''.com Project ID:
Attention: Matthew Myers Phone: (203)562-5771
Langan Engineering&Environ,Services Fax: (203)789-6142
Long Wharf Maritime Center Received Date: 12/0,912019 3:15 PM
555 Long Wharf Drive Analysis Date: 12/09/2019
New Haven,CT 06511 Collected Date: 12/06/2019
Project: 140182705
Test Report. Asbestos Analysis of Bulk Materials via EPA 600IR-931116 Method using Polarized
Light Microscopy
Non-Asbestos Ashastos
Sample Description Appearance Fibrous %Non-Fibrous %Type
120601A BRICKS ON Tan 6%Quartz None Detected
PALLET-EXTERIOR- Non-Fibrous 94%Non-fibrous(Other)
241907309-0001 YELLOW BRICK Homogeneous
SPOTS
120601E BRICKS ON Yellow 2%Quartz None Detected
PALLET-EXTERIOR- Non-Fibrous 98%Non-fibrous(Other)
241901309-0002 YELLOW BRICK Homogeneous
SPOTS
120602A BRICKS ON Gray 100%Non-fibrous(Other) None Detected
PALLET-EXTERIOR- Non-Fibrous
241907309-0003 MORTAR INSIDE Homogeneous
BRICK HOLER
120602E BRICKS ON Gray 1%Cellulose 100%Non-fibrous(Other) None Detected
PALLET-EXTERIOR- Non-Fibrous
241907309.0004 MORTAR INSIDE Homogeneous
BRICK HOLER
f
f
Analyst(-)
Almedina Hodzic(2) Almedina Horizic,Asbestos Laboratory Manager
Tara Svendsen(2) or Other Approved Signatory
EMSL maintains liability limited io cost of ana-Ws.The above analyses were performed in general compliancewithAppendix E to Subpart E of 40 CFR(Previously EPA 600A44-02-020"Interim
Method'),but augmented walla procedures outlined In the 1993 ffnal')version of the method.This report relates only to the samples reported above,and may not be reproduced,except In full,wilhout
written approval by EMSL. EMSL bears no responsibility for sample collection activities or ana"cal method limitations, interpretation and use of test results are the responsiblity of the client, AM
Samples received In acceptable condition unless otherwise noted.This report must not be used by the client to claim product certification,approval,or endorsement by NVLAP, NIST or any agency of
the federal government, EMSL recommends gravrimetria reduction for all non-friable organically bound materials prior to analysis. Estimation of uncertainty is available on request
Samples analyzed by EMSL Analytical,Inc.Wallingford,,CT NVLAP Lob Code 200700-0,
(Lnillat report from:12t0912019 16:18:40
ASB�_PLM_Oeos0001-1.78 Printed:12/912019 4:18 PM Page 1 of 1