HomeMy WebLinkAboutFire Alarm Inspection Report - Inspection - 11 BAYFIELD DRIVE 2/26/2020 4 I 6 Progress Avenue,Unit Tyngsboro,,MA 01879 FIRE ALARM INSPECTION REPORT Property Nat Zane: .............. �: I n i 3 Date: A/1) Address: I ns pecti on Time: Representative, Ll i License No.- Telephone: MonitoringEntity Approving A e c � Contact: Contact; { Telephone: e; t � Telephone: Monitoring Acct Type Transmission Service Mc ull In Weekly Multiplex Monthly Digital Quarterly Reverse priority Semiannually RF Anuallyr jz Other el Dile'r other(Specify); Control Unit Manufacturer: Model M. Circuit Styles: Number of Circuits: Software Rev: Last ]ate System Had Any Service Performance: Last Date that Any Software or Configuration was Revised: Quantity Circuit Style Manual Fire Alarm Pulls Ion Detectors Photo Detectors Duct Detectors Heat Detectors Water low Switches Supervisory Switches Other(Specify): other(Specify).- Other Specify : Other(Specify): Alarm Verification feature isdisabled enabled Pace I of ALARM NOTIFICATION APPLIANCES AND CIRCUIT INFORMATION i h antic Circuit Style , Bells Alt Horns/Strobes chimes - Strobes Speakers { Other Specify):Booster—Fire Lite No.of alarm notification appliance circuits: Are Circuits monitored d for integrity? Yes No SUPERVISORY SIGNAL-INITIATING DEVICES AND CIRCUIT INFORMATION Quantity Circuit Style Building Temp. Site dater Temp. Site Vila to r Level Fire Pump Power Eire Pump Running Fire Pump or Pump ControllerTrouble Fire Pump Running elnerator In Auto Position Generator or Controller Trouble Sll Itch Transfer Generator Engine Running Other(Specify): SIGNALING LINE CIRCUITS Quantity and style of signaling line circuits connect to system Quantity Style(s) SYSTEM POWER SUPPLIES a Primary(Main): Nominal Volta a Amps .266 erculrrent Protection: Type Amps Location ( y Su of Primary Panelboard): r �A Supply Disconnecting deans Location: - f��, � 42 1" L f e Z (b) Secondary Standby: � ......�� Storage Battery:. .� � Calculated capacity to operate system,in hours: 24 ..,,..,.�60 En g 1neid rive ln generator dedicated to fire alarm system: Location of fuel storage: TYPE BATTER'S Dry Cell Lead-Acid Nickel-Cadmium Other(Specify) Sealed Lead-Acid c Emergency or standby system used as a backup to primary power supply,instead of using a secondary power supply Emergency system described in NFPA 70,Article 700 Legally required standby described in C FPA 70,Article 701 ptionaI standby system described in N FPA 70,Article 70 ,w hich also meets the perforrnance requii rem ents of Article 700 or 701. t Page 2 of Building/Site. Inspection Date: D: Smoke Detector DD: Dint Detector D: Bearer Detector D : Door Holder PS: Pull Station NN: Annunciator MRS: Power Suppler D : Damper Activation RESULTS Device Location Zone Address# Pass. Fail i 0 . JA f f . t . # Deficiencies: ust r er Signature-.- .<.. ... - .. ,..m�.� _�..�'•rv:s, Inspector's Signatures: 4 , Pge� . Building/Site: Inspection Date: { r } D: Smoke Detector DD: Duct Detector BD: Beam Detector- DH: Door Holder PS: Pull Station ANN: Annunciator P1 F : Power Supply D : Damper Activation RESULTS Device Location Zone Address# Pecs Fail T t�•� ', .'# f �F fir. `'' Deficiencies: T Customer's S n ture: �.-..__.._ �r..,..•..__, Inspector's Signatures: Pag f 5 PRIOR TO ANY TESTING NOTIFICATIONS ARE MADE Yes No WhoTime t Monitoring Entity J f# .` } WIG Building occupants Building Managem.ent , ram Other(Specify) AHJ Notified of Any Impairment SYSTEM TESTS AND INSPECTIONS TYPE Visual Functional Comments Control Unit Interface Equipment • ± L ps ED Fuses " Primary Power SupplyxY - Trouble Signals Disconnect Switches Ground-Fault Monitoring SECONDARY POWER TYPE Visual Functional Comments Battery Condition 7,111 i Load Voltage lijij"leI Discharge Test _ �,. # Char er Test f41 � Specific Gravity TRANSIENT SUPPRESSORS REMOTE ANNUNCIATORS NOTIFICATION APPLIANCES Audible t Visible f. Y Speakers Voice Clarity ' f -; i XNITIATING AND SUPERVISORY DEVICE TESTS'AND INSPECTIONS Measured i Loc. N Device Type Visual Ck Func Test Fact Setting Settings Pass Fall f Comments: is Page 3 of EMERGENCY COMMUNICATIONS EQUIPMENT T Visual Functional Comments Phone Set Phone-.hacks ' } Tone Generator(s Call-in Signal System Performance Device INTERFACE EQUIPMENT Visual operations Operation (Specify) ,,,........----. (Specify) i (Specify) M .....,.... „.� � SPECIAL HAZARD SYSTEMS (Specify) „M,,...... (Specify) „....__... ....... (Specify) ....,......... - Special Procedures: Comments: t SUPERVISING STATION MONITORING lies,, No Time Comments Alarm Signal Alarm Restoration Trouble Signal Supervisory Signal Supervisory Restoration ration NOTIFICATIONS THAT TESTING IS COMPLETE Who Time Building Management ��' T�, f�,,{f,� � {���0 f Monitoring Agency ' Building Occupants Other (Specify The Following dial not operate correctly: System restored to normal o eratiom Date: - ) : THIS TESTING WAS PREFORMED Ili ACCORDANCE CE WITH APPLICABLE NFPA STANDARDS. Name of lnspecto. # w �.-' { ' # Time: J 4 '" - Signature.* Name of Owner or Representative: i * ate: r+'.X' rJJ+y[ 7Ei��+y*,+�� J' i R i� : r Signature: Page 4 of